Tilt Aggregation Procedure for Kathrein PCA 1 This procedure requires PCA v2.3.3 software on the computer. Begin by launching the PCA software and connecting to the FlexRET module. Click Start Scan and Connect. After the scan is done, you will see the current configuration. The antenna type in this example is 80010892V01. Your type may differ. Click Software Update.

Upload: truongphuc

Post on 13-Jun-2018

307 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

1

This procedure requires PCA v2.3.3 software on the computer.

Begin by launching the PCA software and connecting to the FlexRET module.

Click Start Scan and Connect.

After the scan is done, you will see the current configuration. The antenna type in

this example is 80010892V01. Your type may differ.

Click Software Update.

Page 2: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

2

If the Software Update screen shows 86010153V01 under Product Number and FW_V02.02.00 under

Software Version, proceed directly to the aggregation process on page 9. If not, the firmware on the

FlexRET MUST be updated, or the aggregation files cannot be loaded. For this procedure, continue to

the next page.

Page 3: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

3

On this screen, click Select. Any one of the RET numbers can be used for this

process.

Page 4: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

4

Browse to the location of the files you received, select the file named

86010153_FRET_FW_V02-02-00 and click Open.

Page 5: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

5

Click Start.

Page 6: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

6

You will see a typical progress bar. It will take a few minutes.

Page 7: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

7

When it is done, the Finish button will be enabled and you can click it.

Page 8: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

8

The Device Status screen will reappear. Click Software Update.

Page 9: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

9

Note the Software Version is now V02.02.00 on all the RETs. The product number

will not change if you have just updated the firmware.

Click Select on any of the RETs.

Page 10: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

10

Browse to the location of the files you received and select the antenna type you

are using. Note that your antenna type may vary. Click Open.

Page 11: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

11

Click Start.

Page 12: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

12

This file loads quickly and you will not see a progress bar. Click Finish.

Page 13: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

13

Note that the RETs to be aggregated are in ERROR. That is because they no longer

exist and have been replaced by aggregated RETs.

Click the Device Status button to return to the main screen.

Page 14: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

14

Click Yes to go to the opening screen.

Page 15: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

15

Click Start Scan and Connect.

Page 16: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

16

Note that the newly aggregated RETs have appeared. Note the new Serial

Numbers with the descriptive suffixes.

The ERROR messages indicate the they must be calibrated. Click the Details

button on the first one.

Page 17: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

17

Note the NOT_CALIBRATED Status. Click Calibrate.

Page 18: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

18

This takes several seconds while the aggregated RET is calibrated.

The Status is MOVING during this process.

Page 19: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

19

When it is done, the Status will be OK. Click Back to Device Status.

Page 20: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

20

Calibrate the remaining aggregated RET in the same manner as before.

Page 21: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

21

Click Calibrate.

Page 22: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

22

Note the OK Status message.

Page 23: Tilt Aggregation Procedure for Kathrein PCA · Tilt Aggregation Procedure for Kathrein PCA 2 ... Calibrate the remaining aggregated RET in the same manner as before. Tilt Aggregation

Tilt Aggregation Procedure for Kathrein PCA

23

Click Back to Device Status to confirm proper configuration and Status.