tib module performance at x5 test beam – preliminary studies
DESCRIPTION
TIB module performance at X5 Test beam – preliminary studies. G.Segneri et al. Universita` and INFN - Pisa. Test Beam meeting – October 23 2003. Outline. Detector behavior under different bias voltages Studies on Detector Response Uniformity. Voltage scan for TIB Detectors. - PowerPoint PPT PresentationTRANSCRIPT
TIB module performance at X5 Test beam – preliminary
studies
G.Segneri et al.Universita` and INFN - Pisa
Test Beam meeting – October 23 2003
Outline
• Detector behavior under different bias voltages
• Studies on Detector Response Uniformity
Voltage scan for TIB Detectors
• Study of the detector properties (noise, charge, S/N, cluster width and response function) as a function of the applied voltage
Used runs: TIB peak: 1198, 99, 1202, 03, 04, 14, 15 -
120 GeV TIB dec.: 30020, 24, 27, 33, 36, 39, 42, 46 – 120 GeV , 25 ns beam
Beam Position in TIB Modules
muon beam pion beam
TIB Voltage scan -peak
• Peculiar behaviour at 300 V – hysteresis effect?
TIB Voltage scan – peak (II)
TIB Voltage scan – dec.
TIB Voltage scan – dec. (II)
20% increase in S/N ratio for Vbias = 2Vfd
Response Function
Cluster ShapePeak modeVbias=200V
Dec. modeVbias=200V
Peak modeVbias=450V
Dec. modeVbias=450V
TIB Voltage scan under controlled environmental
conditionsRun numbers:T<23 oC: 30133, 37, 40,
42, 45, 47, 50R.H.<20%: 30154, (62-
66), (69-74)
120 GeV muon beam
beamT<23 oC
Performance reproducible under controlled RH condition signal and noise depend on RH but not their ratio
TIB Voltage scan under controlled environmental
conditions (II)
Voltage Scan for TOB Detectors
Used runs: 30145, 47, 51, 63, 64, 65 – 120 GeV , 25 ns beam – deconvolution mode
TOB mod # 7 TOB mod # 8
TOB mod # 12TOB mod # 11
TOB mod # 10TOB mod # 9
TOB Voltage scan
Noise constant above 200 V Charge collection improvement at very high voltage
TOB module voltage scan (II)
25% decrease in S/N for Vbias = Vfd
TOB module voltage scan (III)
Less 10% of charge loss at Vbias/Vdepl>1.5 Constant cluster width above Vbias=300 V
Comparison TIB/TOB
95% of S/N highest value at 1.7 (1.5) Vdepl for TOB (TIB) modules
Sensor Uniformity Studies• Study of the TIB sensor properties (noise,
charge, S/N, respone function) as a function of the cluster position
Used runs: Run 1351-3: peak mode, pion beam, approx.
500,000 events Run 1484: dec mode, 25 ns pion beam,
approx. 1,500,000 events
Groups of 16 strips
Groups of 8 strips Groups of 16 strips
Conclusions
• TIB and TOB modules behave as expected except
in some runs to be understood • Dependence on RH to be investigated more
deeply (next talk?)• Uniformity of detector performance as a
function of the position was successfully tested in high statistics runs
• Work still in progress…