Page 1: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

Three-phase asynchronous compact drives

Design series M21 ...

Page 2: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

Cover pictureCompact drives

Page 3: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

Advantages of compact drives 4

Product range of VEM compact drives 5

Compact drives of series M21 ... T 0.55 to 7.5 kW 6(vector controlled version)

General technical data series M21 ... T 7

Drive selection data series M21R ... T 8

2-pole drives 8

4-pole drives 10

6-pole drives 12

8-pole drives 13

Dimensions and dimensional drawings 14

Compact drives of series M21 ... VS 5.5 to 22 kW 16(VS = vector controlled version)

General technical data series M21 ... VS 17

Drive selection data series M21R ... VS 18

2-pole drives 18

4-pole drives 19

Dimensions and dimensional drawings 20

Range of products 20

Table of contents

Page 4: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

4

The basis of VEM compact drive are two components, therobust VEM grey cast iron motor and a drive electronic that isoptimised for motor operation. When thinking about the engi-neering design, the most importance was attached to a highvibration strength of the inverter and a sound design of thewhole drive unit.

Whereas the inverters of the design series M21...T will becooled by the ventilator of the motor, the inverters of thedesign series M21... possess a separate ventilation system.

The compact drives are available in all standard types of con-struction, similar to the standard motors. The high type ofprotection IP 54 (for compact drives M21…T the type of protection is IP 55 or higher as an option) enables operationeven under unfavourable ambient conditions.

VEM compact drives can be used in applications where vari-able motor speeds are necessary for optimising technologicalprocesses. In particular the change over of installations andmachines that were operated so far with constant speed isremarkably easy. The existing motor can be exchanged with-out any difficulty with a compact drive. Additional designmeasures or new cables are not necessary. The motor speedcan now be adjusted optimal to the requirements. The valueof the installation or the machine will be increased due to theimprovement of the technological processes and the additio-nal optimisation of the energy consumption.

There are other, manifold advantages in using compact drives.Not alone the operation and the handling, but also the projectplanning, acquisition, installation and start of operation of com-pact drives shows significant cost advantages compared toseparately operated components.

General advantages • no floor or wall space for switch cabinet necessary• high vibration strength because of solid total design• high type of protection (at least IP54) even for inverter

as standard

Reduction of labour time due to reduction of project planning activities • no project planning of an electric service cabinet• no inverter project planning • no project planning of output chokes, du/dt – or sine filters• no project planning of cables between inverter and motor • no testing of peak voltages and rates of voltage rising at

the motor terminal • PTC thermistor analysis as standard • integrated PID-controller as standard • serial communication with RS485, Profibus DP, as option• radio interference filter class A as standard (class B as option)

Saving of materials• no electric service cabinet for the inverter necessary • no special insulation because no invalid peak voltages

develop• no output chokes, du/dt - or sine filters• no control cable for PTC thermistor analysis• no need for screened motor cables (only unscreened

cables for electric supply connection is necessary)

Reduction of labour time because of simple installationand connection• no installation of inverter • no wiring between motor and inverter• confusion about inverter input and output not possible • EMC-compatible installation at the output of the inverter is

not necessary

Reduction of labour time due to easy start of operation• immediately operable drive • parameters of motor already adjusted at production • no wrong connection of motor cables (wrong direction of

rotation)• easy adjusting of parameters with the control panel directly

on the machine and therefore precise and fast adjustmentof inverter parameters to the technological process

Advantages of compact drives

Page 5: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

5

Design series M21 ... 5.5 to 22 kW, vector controlled (VS)

Product range VEM compact drives

Design series M21 ... T 0.55 to 7.5 kW, vector controlled

Page 6: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

6

Compact drives of series M21 ... T 0.55 to 7.5 kW(vector controlled design)

For this design variation the cooling of the inverter is integra-ted in the cooling system of the motor, that means the coo-ling will be done by the ventilator of the motor or if necessa-ry by an axially mounted forced-ventilation unit of the motor.Due to favourable motor connection of the inverter and thesmall dimensions, the mounting space of the standard asyn-chronous motor will be exceeded only slightly.

The special product advantages of this design variationare:• type of protection IP 55, IP 66 as option• easy to maintain due to pluggable electric connection

between motor and inverter, after loosening of the three orfour screws for mechanically fixing of the inverter on themotor, a fast separation of both components is possibleand therefore it is not necessary to exchange the completecompact drive in case of damage.

• variable pulse frequency, that can be adjusted up to 6 orrespectively 14 kHz, whereas the pulse frequency can belowered automatically to 2 kHz as protection of the inverteragainst warming.

The operation of the drive can be done with the terminal blockX101. The program Motion Control MCT 10 is available forserial communication via interface RS 485. More detail canbe found in the project planning manual for compact drivesM21 … T. In addition the inverter design version with PROFIBUS DPV1can be supplied with a baud rate of 3 MB or 12 MB.

Included in the additional offer for local and remote controland for drive parameterisation (for more details see projectplanning manual) are:

Set value potentiometer for installationin a screwed cable gland of the inverter.

LCP2 (Local Control Panel) for use aslocal control unit and at the same timecomplete interface for parameterisation,operation and control with severalpossibilities for fixed and removableconnection (IP 65 – female connector)at the inverter.

LOP (Local Operation Panel) withapprox. 2 m cable connection for useas digital potentiometer and start andstop button.

Page 7: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

7

Activation and supply module for hol-ding brake for installation in a screwedcable gland of the inverter.

Set of connectors for installation in ascrewed cable gland of the inverter for simultaneous operation of Profibusand LCP2.

Supply voltage 380 / 400 / 415 / 440 / 460 / 480 V ± 10% 3AC

Supply frequency 50 / 60 Hz ± 2%

Maximum current for 60 s 160%

Thermal winding protection 3 units of PTC thermistors TPM 140

Torque characteristics free adjustable, constant torque or geometrically increasing torque (breakaway torque, low, medium, high)

Frequency range 0 ... 132 Hz

Speed range 2-pole: 0 ... 7920 min-1 4-pole: 0 ... 3960 min-1

(synchronous speed) 6-pole: 0 ... 2640 min-1 8-pole: 0 ... 1980 min-1

Pulse frequency 0.75 ... 1.5 kW: 1,5 kHz ... 14 kHz (free adjustable)2.20 ... 7.5 kW: 1,5 kHz ... 6 kHz (free adjustable)

Radio noise suppression EN 61800-3 standard: 1. sales mode for restricted distributionwith filter B1: 1. sales mode for unrestricted distribution

Type of protection IP 55 (IP 56, IP 66)

Type of construction / mounting position IM B3, B5, B14, B35, B34 including auxiliary types of construction without IM 1071, IM 2071 und IM 2171

Cable entry 0.55 ... 3.0 kW: 3 x M20 x 1.54.0 ... 7.5 kW: 1 x M25 x 1.5 ; 2 x M20 x 1.5

Ambient temperature at operation 0°C ... +40°C (full load); -10°C ... +40°C (reduced load)for storage / transport -25 °C ... +65 / 70°C

Altitude <1000 m (output reduction dependent on atmospheric pressure)

General technical data series M21 ... T

Page 8: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

Type M21R ... T 71 G2 80 K2 80 G2 90 S2 90 L2 100L2 112M2 112MX2 132 S2 112MV2 132 SX2

H [mm] 71 80 80 90 90 100 112 112 132 112 132

PNom. [kW] 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 5.5 7.5 7.5

nNom.. [min-1] 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000

nmin [min-1] 0 0 0 0 0 0 0 0 0 0 0

nmax [min-1] 7360 7360 7480 7500 7520 7560 7660 7630 7630 7600 7600

MNom. [Nm] 1.8 2.5 3.7 5.0 7.4 10.0 13.2 18.2 18.2 24.9 24.9

I1 [RMS], 400 V [A] (1) 1.5 2.1 2.6 3.5 4.8 6.4 8.5 11.1 11.1 14.8 14.8

I1 [RMS], 380 V [A] 1.6 2.0 (3) 2.6 3.4 (3) 4.9 (3) 6.6 (3) 8.4 (3) 11.2 11.2 14.9 14.9

I1 [RMS], 480 V [A] 1.4 1.7 2.2 3.0 4.3 5.5 7.4 9.4 9.4 12.5 12.5

I1 [RMS], 480 V P60Hz [A] 1.6 2.0 2.7 3.7 4.8 6.7 8.5 11.1 11.1 14.9 14.9

[%] 68.4 72.4 74.8 79.0 80.5 79.7 82.1 84.5 84.5 83.5 83.5

cos (nominal load) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

LW (A) [dB] (2) 65.4 66.5 69.8 68.1 74.5 72.7 75.5 80.2 80.2 81.8 81.8

J [kgcm2] 3.2 5.7 7.0 13.0 17.0 27.5 45.0 55.0 55.0 68.0 68.0

mdrive [kg] 1003 12.8 14.3 18.8 23.1 29.1 37.7 48.4 50.4 56.4 58.4

(1) data on name plate(2) no load sound power level (3) load with reduced nominal torque

8

Drive selection data series M21R ... T Surface cooled design version

All data is valid for the design at 400 V, 50 Hz and for the factory settings of the inverter with constanttorque and slip compensation 100%

n

o

2-pole drives

Page 9: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

9

1.1

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.00 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000

Speed [min-1]

M/M

Nom

.

71 G2/80 K2/90 L2/112 M2

80 G2

90 S2

100 L2

112 MX2 / 132 S2

112 MV2 / 132 SX2

Characteristics M/MNom. (load for constant torque, optimal IxR – rise)

Page 10: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

10

Drive selection data series M21R ... T Surface cooled design version

All data is valid for the design at 400 V, 50 Hz and for the factory settings of the inverter with constanttorque and slip compensation 100%.

Type M21R ... T 80 K4 80 G4 90 S4 90 L4 100 L4 100 LX4 112 M4 112 MX4 132 S4 132 M4

H [mm] 80 80 90 90 100 100 112 112 132 132

PNom. [kW] 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 5.5 7.5

nNom. [min-1] 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500

nmin [min-1] 0 0 0 0 0 0 0 0 0 0

nmax [min-1] 3695 3695 3720 3695 3750 3775 3790 3760 3760 3820

MNom.. [Nm] 3.8 5.1 7.5 10.3 14.8 20.0 26.7 37.1 37.1 49.1

I1 [RMS], 400 V [A] (1) 1.5 2.0 2.6 3.7 4.8 6.3 8.3 11.6 11.6 15.3

I1 [RMS], 380 V [A] 1.6 2.1 2.6 (3) 3.6 (3) 5.0 6.5 (3) 8.5 11.5 11.5 16.0

I1 [RMS], 480 V [A] 1.4 1.8 2.5 3.2 4.4 5.9 7.2 10.1 10.1 13.0

I1 [RMS], 480 V, P60Hz [A] 1.6 2.1 2.8 3.8 4.9 6.5 8.3 11.5 11.5 15.1

[%] 71.8 71.8 74.8 74.8 77.2 79.7 81.4 81.5 81.5 84.2

cos (nominal load) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

LW (A) [dB] (2) 61.2 59.0 63.5 64.6 66.9 69.6 68.0 80.6 80.6 75.8

J [kgcm2] 8.7 10.7 20.7 26.0 40.0 72.5 90.0 111.0 111.0 280.0

mdrive [kg] 12.7 13.8 18.3 20.8 27.6 34.1 42.7 55.4 57.4 80.4

(1) data on name plate(2) no load sound power level (3) load with reduced nominal torque

n

o

4-pole drives

Page 11: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

1.1

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.00 500 1000 1500 2000 2500 3000 3500 4000

Speed [min-1]

M/M

Nom

.

11

Characteristics M/MNom. (load for constant torque, optimal IxR - rise)

80 K4/90 S4

80 G4

90 L4

100 L4

100 LX4

112 M4

112 MX4 / 132 S4

132 M4

Page 12: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

12

Drive selection data series M21R ... T Surface cooled design version

All data is valid for the design at 400 V, 50 Hz and for the factory settings of the inverter with constanttorque and slip compensation 100%.

Type M21F ... T 80 K6 80 G6 90 S6 90 L6 100 L6 112 M6 112 MX6 132 S6 112 MV6 132 SX6

H [mm] 80 80 90 90 100 112 112 132 112 132

Pdrive [kW] 0.37 0.55 0.75 1.1 1.5 2.2 3.0 3.0 4.0 4.0

nNom. [min-1] 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

nmin [min-1] 0 0 0 0 0 0 0 0 0 0

nmax [min-1] 2415 2415 2465 2465 2495 2510 2465 2465 2520 2520

MNom. [Nm] 3.9 5.7 7.7 11.2 15.2 22.1 30.6 30.6 40.0 40.0

I1 [RMS] [A] 1.2 1.6 2.1 2.9 3.7 5.0 7.0 7.0 8.8 8.8

[%] 61.5 66.1 69.1 70.5 75.1 78.2 76.7 76.7 77.7 77.7

cos (nominal load) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

LW (A) [dB] (1) 65.1 64.6 61.3 67.3 71.8 67.4 76.5 76.5 74.8 74.8

J [kgcm2] 13.0 17.5 32.5 42.5 62.5 122.5 139.0 139.0 230.0 230.0

mdrive [kg] 13.1 14.6 18.8 21.8 28.1 37.6 42.7 47.8 43.0 48.1

(1) no load sound power level

n

o

6-pole drives

Page 13: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

13

Type M21F ... T 80 G8 90 S8 90 L8 100 L8 100 LX8 112 M8 112 MX8 132 S8 112 MV8 132 SX8 160 M8

H [mm] 80 90 90 100 100 112 112 132 112 132 160

Pdrive [kW] 0.25 0.37 0.55 0.75 1.1 1.5 2.2 2.2 3.0 3.0 4.0

nNom. [min-1] 750 750 750 750 750 750 750 750 750 750 750

nmin [min-1] 0 0 0 0 0 0 0 0 0 0 0

nmax [min-1] 1835 1845 1835 1860 1860 1860 1805 1805 1860 1860 1875

MNom. [Nm] 3.4 5.0 7.6 10.2 14.9 20.3 30.7 30.7 40.6 40.6 53.8

I1 [RMS] [A] 1.0 1.3 1.8 2.2 2.7 3.7 5.4 5.4 7.4 7.4 9.1

[%] 55.2 59.6 62.3 67.0 74.9 76.5 75.9 75.9 73.0 73.0 77.2

cos (nominal load) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

LW (A) [dB] (1) 65.8 66.0 69.4 67.8 72.3 72.4 74.0 74.0 73.9 73.9 83.7

J [kgcm2] 17.5 30.0 37.5 62.5 90.0 122.5 139.0 139.0 230.0 230.0 430.0

mdrive [kg] 14.1 17.1 20.8 25.8 30.8 37.6 41.1 42.3 43.0 44.2 80.4

(1) no load sound power level

n

o

8-pole drives

Page 14: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

71G2 90 160 105 140 112 110 70 95 11 9 8 10 14 116 130 85 115

80K2 100 200 120 160 125 130 80 110 12 10 8 10 19 125 165 100 130

80G2 100 200 120 160 125 130 80 110 12 10 8 10 19 125 165 100 130

90S2 100 200 140 160 140 130 95 110 14 10 10 10 24 130 165 115 130

90L2 125 200 140 160 140 130 95 110 14 10 10 10 24 155 165 115 130

100L2 140 250 160 200 160 180 110 130 15 11 10,5 12 28 175 215 130 165

112M2 140 250 160 200 190 180 110 130 18 11 10 12 28 180 215 130 165

112MX2 140 250 160 200 190 180 110 130 18 11 10 12 28 180 215 130 165

112MV2 140 250 160 200 190 180 110 130 18 11 10 12 28 180 215 130 165

132S2 140 300 200 - 216 230 130 - 18 11 12 - 38 180 265 165 -

132SX2 140 300 200 - 216 230 130 - 18 11 12 - 38 180 265 165 -

80K4 100 200 120 160 125 130 80 110 12 10 8 10 19 125 165 100 130

80G4 100 200 120 160 125 130 80 110 12 10 8 10 19 125 165 100 130

90S4 100 200 140 160 140 130 95 110 14 10 10 10 24 130 165 115 130

90L4 125 200 140 160 140 130 95 110 14 10 10 10 24 155 165 115 130

100L4 140 250 160 200 160 180 110 130 15 11 10,5 12 28 175 215 130 165

100LX4 140 250 160 200 160 180 110 130 11 11 10 12 28 171 215 130 165

112M4 140 250 160 200 190 180 110 130 18 11 10 12 28 180 215 130 165

112MX4 140 250 160 200 190 180 110 130 18 11 10 12 28 180 215 130 165

132S4 140 300 200 - 216 230 130 - 18 11 12 - 38 180 265 165 -

132M4 178 300 200 250 216 230 130 180 16 12 12 15 38 218 265 165 215

B5/35 B14/34 B5/35 B14/34 B5/35 B14/34 B5/35 B14/34

M21 ... T a a1 b b1j6 c c1 d k6 e e1

14

Dimensions and dimensional drawings

Type of construction IM B3 Type of construction IM B5 Type of construction IM

Page 15: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

138 3.5 3.0 3.0 124 71 206 240 30 32 137 8 9 M6 M8 107 45 141 206

168 3.5 3.0 3.5 139 80 249 256 40 38 145 10 11 M6 M8 113 50 141 206

168 3.5 3.0 3.5 139 80 249 285 40 38 149 10 11 M6 M8 130 50 159 231

178 3.5 3.0 3.5 157 90 275 298 50 40 156 10 11 M8 M8 133 56 159 231

178 3.5 3.0 3.5 157 90 297 329 50 40 166 10 11 M8 M8 151 56 176 257

192 4.0 3.5 3.5 177 100 331 344 60 45 173 12 14 M8 M10 156 63 176 257

224 4.0 3.5 3.5 196 112 357 375 60 50 191 12 14 M8 M10 172 70 197 287

224 4.0 3.5 3.5 196 112 421 437 60 50 191 12 14 M8 M10 199 70 245 358

224 4.0 3.5 3.5 196 112 421 437 60 50 191 12 14 M8 M10 199 70 245 358

256 4.0 3.5 - 196 132 460 476 80 50 191 12 14 M10 - 218 89 245 358

256 4.0 3.5 - 196 132 460 476 80 50 191 12 14 M10 - 218 89 245 358

168 3.5 3.0 3.5 139 80 249 256 40 38 145 10 11 M6 M8 113 50 141 206

168 3.5 3.0 3.5 139 80 249 256 40 38 145 10 11 M6 M8 113 50 141 206

178 3.5 3.0 3.5 157 90 275 298 50 40 156 10 11 M8 M8 133 56 159 231

178 3.5 3.0 3.5 157 90 297 298 50 40 156 10 11 M8 M8 133 56 159 231

192 4.0 3.5 3.5 177 100 331 344 60 45 173 12 14 M8 M10 156 63 176 257

188 4.0 3.5 3.5 196 100 357 346 60 32 184 12 14 M8 M10 158 63 176 257

224 4.0 3.5 3.5 196 112 391 375 60 50 191 12 14 M8 M10 172 70 197 287

224 4.0 3.5 3.5 196 112 421 437 60 50 191 12 14 M8 M10 199 70 245 358

256 4.0 3.5 - 196 132 460 476 80 50 191 12 14 M10 - 218 89 245 358

256 4.0 3.5 3.5 258 132 481 460 80 50 261 12 14 M10 M12 200 89 245 358

B5/35 B14/34 B5/35 B14/34

f f1 g h k k2 l n p s s1 A w1 x z

15

B14 Type of construction IM B34 Type of construction IM B35

Page 16: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

16

The inverter is fitted with a ventilation system that is inde-pendent of the motor.

The speed of the drive can be adjusted without external control panel in the standard design version (M version).

Comfortable means of operation are: • external unit for operation and change of parameters • serial interface RS 485 • Bus connections• customer modified interface

Remarkable is the variety of serial interfaces:• 8 digital inputs with free choice of parameters and

potential separation• 2 analogue inputs with free choice of parameters and

potential separation• 2 digital and analogue outputs each with free choice of

parameters and potential separation• 2 relays outputs with free choice of parameters

Index of the accessories

O minimal panel with LED’s for supply/operation/errorM design O + operation panel with buttons (Standard)P Unit for operation and parameter changes Bx Bus connection (x = 0 RS 485 x = 1 Profibus)

can be completed with:

OBx O + Bus connectionMBx M + Bus connectionOP O + unit for parameter changestMP M + unit for parameter changesOBxP OBX + unit for parameter changesMBxP MBX + unit for parameter changes

and also possible for the motor:

HS High speed design version (for adjusting ranges of frequency of more than 60 Hz-100 Hz)

Compact drives of series M21 ... VS 5.5 to 22 kW (vector controlled design version)

O design version minimal panel with LED’sfor supply/operation/error

M design version design O + operation panel with buttons(Standard)

Page 17: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

17

Supply voltage 400 V +10/-10% 3AC

Supply frequency 50/60Hz

Maximum current for 30s 120 %

Thermal winding protection 3 units of PTC thermistors as standard

Frequency range 0 ... 60 Hz (HS: up to 100 Hz)

Speed range 2-pole 0 ... 3600 min-1 (HS: up to 6000 min-1)4-pole 0 ... 1800 min-1 (HS: up to 3000 min-1)

Pulse frequency 1.5 ... 6 kHz

Radio noise suppression EN 61800-3 + A11 2. sales mode / 1. sales mode for restricted distribution

Type of protection IP 54

Type of construction IM B3, B5, B35 including the auxiliary types of construction without IM 1071 and IM 2071

Cable entry 1 x M 32x1.5; 5.5 ... 7.5 kWM 40x1.5; 11 .... 22 kW

Size of cable entry 3 x M 25

Ambient temperatureOperation -20 up to +40°C (without condensation)Storage/Transport -20 up to +65°C

Altitude <1000 m above sea level

General technical data series M21 ... VS

MP design versiondesign M + unit for operation and parameterchanges

Page 18: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

18

1.2

1

0.8

0.6

0.4

0.2

0.00 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000

Speed [min-1]

M/M

Nom

.

Drive selection data series M21R ... VSSurface cooled design version

Type M21R ... 132S2 132SX2 160M2 160MX2 160L2 180M2

H [mm] 132 132 160 160 160 180

PNom. [kW] 5.5 7.5 11 15 18.5 22

nNom. [min-1] 2860 2900 2900 2930 2920 2935

MNom. [Nm] 18 25 36 49 60 72

I1 [RMS] [A] 10 13,5 21 27 33 39,5

[%] 83.6 84.3 85.7 86.7 87.3 87.8

cos (nominal load) 0.99

J [kgm2] 0.0081 0.011 0.0258 0.0575 0.0675 0.105

m [kg] 60 77 121 150 181 212

n

o

2-pole drives

Speed-torque-characteristics (compact drives with 2-pole motors)

self ventilation

forced ventilation

Page 19: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

19

Type M21R ... 132S4 132M4 160M4 160L4 180M4 180L4

H [mm] 132 132 160 160 180 180

PNom. [kW] 5.5 7.5 11 15 18.5 22

nNom. [min-1] 1440 1450 1450 1465 1460 1465

MNom. [Nm] 37 50 73 99 122 144

I1 [RMS] [A] 10 13.5 21 27 33 39.5

[%] 83.4 84.3 85.7 86.7 87.3 87.7

cos (nominal load) 0.99

J [kgm2] 0.015 0.028 0.035 0.078 0.09 0.138

m [kg] 70 90 132 150 183 217

n

o

4-pole drives

1.2

1

0.8

0.6

0.4

0.2

0.00 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000

Speed [min-1]

M/M

Nom

.

Speed-torque-characteristics (compact drives with 4-pole motors)

self ventilation

forced ventilation

Page 20: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

1620

Dimensions and dimensional drawings

132S2 VS 140 300 160 200 216 230 110 130 16 12 10 12 38 180 265 130 165 256

132SX2 VS 140 300 160 200 216 230 110 130 16 12 10 12 38 180 265 130 165 256

160M2 VS 210 350 200 250 254 250 130 180 18 13 12 12 42 257 300 165 215 296

160MX2 VS 210 350 250 300 254 250 180 230 18 13 12 12 42 257 300 215 265 296

160L2 VS 254 350 250 300 254 250 180 230 18 13 12 12 42 301 300 215 265 296

180M2 VS 241 350 - - 279 250 - - 20 13 - - 48 288 300 - - 328

132S4 VS 140 300 160 200 216 230 110 130 16 12 10 12 38 180 265 130 165 256

132M4 VS 178 300 200 250 216 230 130 180 16 12 12 12 38 218 265 165 215 256

160M4 VS 210 350 200 250 254 250 130 180 18 13 12 12 42 257 300 165 215 296

160L4 VS 254 350 250 300 254 250 180 230 18 13 12 12 42 301 300 215 265 296

180M4 VS 241 350 300 - 279 250 230 - 20 13 12 - 48 288 300 265 - 328

180L4 VS 279 350 - - 279 250 - - 20 13 - - 48 326 300 - - 328

4 3.5 3.5 217

4 3.5 3.5 217

5 3.5 4.0 258

5 4.0 4.0 313

5 4.0 4.0 313

5 - - 351

4 3.5 3.5 217

4 3.5 4.0 258

5 3.5 4.0 258

5 4.0 4.0 313

5 4.0 - 313

5 - - 351

B5/35 B14/34 B5/35 B14/34 B5/35 B14/34 B5/35 B14/34 B5/35 B14/34

M21 ... Type a a1 b b1j6 c c1 d k6 e e1 f f1 g

Type of construction IM B3 Type of construction IM B5 Type of construction IM

Page 21: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

21

132 459 - 80 55 50 454 472 454 472 432 12 14 M8 M10 41 10 89 -

132 459 - 80 55 50 454 472 454 472 432 12 14 M8 M10 41 10 89 -

160 559 - 110 60 55 551 566 551 566 520 15 18 M10 M12 45 12 108 -

160 571 - 110 60 55 579 594 579 594 576 15 18 M12 M12 45 12 108 -

160 609 - 110 60 55 579 594 579 594 576 15 18 M12 M12 45 12 108 -

180 635 - 110 65 62 619 619 - 614 - 15 18 - - 51.5 14 121 -

132 459 - 80 55 50 454 472 454 472 432 12 14 M8 M10 41 10 89 -

132 481 - 80 55 50 474 472 474 472 472 12 14 M10 M12 41 10 89 -

160 559 - 110 60 55 551 566 551 566 520 15 18 M10 M12 45 12 108 -

160 609 - 110 60 55 579 594 579 594 579 15 18 M12 M12 45 12 108 -

180 609 - 110 65 62 594 589 594 589 576 15 18 M12 - 51.5 14 121 -

180 680 - 110 65 62 619 619 - 614 - 15 18 - - 51.5 14 121 -

31 35 256 340 M32x1.5

31 35 256 340 M32x1.5

28 35 296 410 M40x1.5

41 35 296 410 M40x1.5

43 35 328 456 M40x1.5

52 35 328 456 M40x1.5

31 35 256 340 M32x1.5

39 35 256 340 M32x1.5

28 35 296 410 M40x1.5

41 35 296 410 M40x1.5

43 35 328 456 M40x1.5

52 35 328 456 M40x1.5

B3 B35 B34 B5 B14 B5/B35 B14/B34 Screwedcable glands

h k k2 l m n p s s1 t u w1 A A1 BI x z r

B14 Type of construction IM B34 Type of construction IM B35

Page 22: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

22

Three phase standard motors

Shaft height 56-355, IP 55Squirrel-cage motor 0.06-500 kWSlip-ring motor 4-315 kWBasic speeds: 3000, 1500, 1000, 750min-1

Modifications

• Foot and flange design • Dual-speed• Dual-voltage • Installed star-delta-switch • Explosion protection for the types of protection EEx e,

EEx d and EEx nA• Motors with seawater protection • Motors for use in dairies • With forced ventilation • Design version with thermal winding protection • Increased safety up to IP 65• Energy saving motors according to CEMEP and EPAct• Brake motors • Fire gas motors • Built-in motors 0.06-90 kW• Motors for use in mechanical smoke and heat exhaust

ventilators• Helical gear motors • Helical worm gear motors • Adjustable gear motors

Three-phase asynchronous motorsup to shaft height 400, IP 55 low voltage design Squirrel-cage and slip-ring motor up to 500 kW with mechanical and electrical modifications

Single-phase asynchronous motors

Shaft height 56-112Squirrel-cage motor IP 55with operating capacitor 0.06-1.5 kW

Three-phase special drives

for driving of • cranes in metallurgical plants 4.8-315 kW• winches and cranes in marine applications • roller table motors 0.06-500 kW (4-pole)

Motors for all sorts of equipment

• Three-phase motors for special applications • Built-in motors for example for refrigerant compressors

Three-phase asynchronous generators

• Output 8 - 500 kVA (4-pole)

Compact drives

• Output 0.55-22 kW

Range of products

Page 23: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

23

Page 24: Three-phase asynchronous compact drives · Three-phase asynchronous compact drives Design series M21 ... Cover picture Compact drives. ... nal optimisation of the energy consumption

we get things moving

VE

M/0

6-00

1 E

/010

7 G

DP

rinte

d in

the

Fed

eral

Rep

ublic

of

Ger

man

y. C

hang

es r

eser

ved

.ar

ture

grap

hik

des

ign

VEM motors GmbH

Carl-Friedrich-Gauß-Strasse 1D-38855 WernigerodeTelephone: +49 - (0) 39 43-68 -0Telefax: +49 - (0) 39 43-68 -21 20

E-Mail: [email protected]: www.vem-group.com

VEM motors Thurm GmbH

Äußere Dresdner Strasse 35D-08066 ZwickauTelephone: +49 - (0) 375 -427-0Telefax: +49 - (0) 375 -427-383

E-Mail: [email protected]: www.vem-group.com