thorlux light line -...

8
THORLUX LIGHT LINE 70 www.thorlux.com/suspended Dec ‘12

Upload: dinhnhi

Post on 20-Nov-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THORLUX LIGHT LINE - lcclighting.no.24nb4.srv.ip.nolcclighting.no.24nb4.srv.ip.no/images_hovedside/thorlux-light-line... · THORLUX LIGHT LINE Continuous suspended direct/indirect

THORLUX LIGHT LINE

70 www.thorlux.com/suspended Dec ‘12

Page 2: THORLUX LIGHT LINE - lcclighting.no.24nb4.srv.ip.nolcclighting.no.24nb4.srv.ip.no/images_hovedside/thorlux-light-line... · THORLUX LIGHT LINE Continuous suspended direct/indirect

Dec ‘12 www.thorlux.com/suspended 71

Page 3: THORLUX LIGHT LINE - lcclighting.no.24nb4.srv.ip.nolcclighting.no.24nb4.srv.ip.no/images_hovedside/thorlux-light-line... · THORLUX LIGHT LINE Continuous suspended direct/indirect

72 www.thorlux.com/suspended Dec ‘12

Page 4: THORLUX LIGHT LINE - lcclighting.no.24nb4.srv.ip.nolcclighting.no.24nb4.srv.ip.no/images_hovedside/thorlux-light-line... · THORLUX LIGHT LINE Continuous suspended direct/indirect

l Extruded aluminium body and die cast ends finished light textured silver (RAL 9006)l High performance LG7:2005 (<1500cd/m2 @ 65o) optical systeml Direct/indirect illuminationl High efficiency satinised polycarbonate uplight diffuserl Single and twin lamp versions in same body profilel Supplied fully assembledl Two miniaturised easily adjustable wire suspensions suppliedl 3.5m supply lead fittedl Fitted with 4000K lamp(s)

SPECIFICATION

ACCESSORY

APPROX. DESCRIPTION CAT. No. kg

Surface wiring tidy LL 13361 0.4

STA

ND

ARD

NOMINAL APPROX. SIZE (mm) LAMP CAT. No. kg CIRCUIT

1 x 28W T5 LL 13337D 4.9

1200 2 x 28W T5 LL 13338D 5.0

1 x 35W T5 LL 13339D 5.3 2 x 35W T5 LL 13340D 5.4

1500 1 x 49W T5 LL 13341D 5.3

2 x 49W T5 LL 13342D 5.4

1 x 28W T5 LL 13331 4.9 J/D/T

1200 2 x 28W T5 LL 13332 5.0 J/D/T

1 x 35W T5 LL 13333 5.3 J/D/T 2 x 35W T5 LL 13334 5.4 J/D/T

1500 1 x 49W T5 LL 13335 5.3 J/D/T

2 x 49W T5 LL 13336 5.4 J/D/T

SMA

RT

RANGE

Individual luminaire comprises:Pre-wired body assembly complete with fitted end caps, 4 or 8 core flying-lead, louvre, uplight diffuser and two sliding wire suspensions.

INFORMATION

Smart Micro-Pod

DIMENSIONS

28W - 127635W - 157649W - 1576

120

56

165

40

Smart Micro-pod

828

Individually suspended direct/indirect T5 luminaires THORLUX LIGHT LINE

Web Link: Smart System

IP20 T5

CIRCUIT TYPE - suffix catalogue number with: J - non-dimming (HF fluorescent) / D - dimming (1-10V) / T - dimming (DSI) e.g. LL 13331J etc. Smart versions use digital dimming gear and are always suffixed D

EMERGENCY VERSION - prefix catalogue number with: ELL - Emergency / TLL - AutoTest e.g. ELL 13331J etc. Emergency and AutoTest versions add 0.7kg to weights listed.

Dec ‘12 www.thorlux.com/suspended 73

Page 5: THORLUX LIGHT LINE - lcclighting.no.24nb4.srv.ip.nolcclighting.no.24nb4.srv.ip.no/images_hovedside/thorlux-light-line... · THORLUX LIGHT LINE Continuous suspended direct/indirect

l Extruded aluminium body and die cast ends finished light textured silver (RAL 9006)l High performance LG7:2005 (<1500cd/m2 @ 65o) optical systeml Direct/indirect illuminationl High efficiency satinised polycarbonate uplight diffuserl Continuously mounted using link kitsl Single and twin lamp versions in same body profilel Supplied fully assembledl Supplied with easily adjustable wire suspensions and fitted plug and socket connectionsl Fitted with 4000K lamp(s)

ACCESSORIES

APPROX. DESCRIPTION CAT. No. kg

Link kit LL 13355 0.2

End kit 2 ends per kit LL 13360 1.3

Surface wiring tidy LL 13361 0.4

Corner joint kit LL 14285 4.0

End to end continuous system consists of luminaires joined with a link kit and finished with an end kit.

Continuous luminaire comprises:Body assembly with fitted plug and socket connections, louvre, uplight diffuser and one sliding wire suspension.

Link kit comprises: 40mm link extrusion and fasteners.

End kit comprises: Two die-cast ends, one wire suspension, one 8 core supply cable with fitted plugs.

INFORMATION

DIMENSIONS

28W - 118935W - 148949W - 1489

56

165

40

Smart Micro-pod

784

THORLUX LIGHT LINE Continuous suspended direct/indirect T5 luminaires

IP20 T5

SPECIFICATION

RANGE - Order luminaire type, end kit and link kits/infill sections as required

STA

ND

ARD

NOMINAL APPROX. SIZE (mm) LAMP CAT. No. kg CIRCUIT

1 x 28W T5 LL 13349D 4.4

1200 2 x 28W T5 LL 13350D 4.5

1 x 35W T5 LL 13351D 4.8 2 x 35W T5 LL 13352D 4.9

1500 1 x 49W T5 LL 13353D 4.8

2 x 49W T5 LL 13354D 4.9

1 x 28W T5 LL 13343 4.4 J/D/T

1200 2 x 28W T5 LL 13344 4.5 J/D/T

1 x 35W T5 LL 13345 4.8 J/D/T 2 x 35W T5 LL 13346 4.9 J/D/T

1500 1 x 49W T5 LL 13347 4.8 J/D/T

2 x 49W T5 LL 13348 4.9 J/D/T

CIRCUIT TYPE - suffix catalogue number with: J - non-dimming (HF fluorescent) / D - dimming (1-10V) / T - dimming (DSI) e.g. LL 13343J etc. Smart versions use digital dimming gear and are always suffixed D

EMERGENCY VERSION - prefix catalogue number with: ELL - Emergency / TLL - AutoTest e.g. ELL 13343J etc. Emergency and AutoTest versions add 0.7kg to weights listed.

NOTE: It is recommended that a maximum of 10 Light Line Continuous luminaires are connected to each 10A fused light circuit

SMA

RT

Web Link: Smart System

74 www.thorlux.com/suspended Dec ‘12

Page 6: THORLUX LIGHT LINE - lcclighting.no.24nb4.srv.ip.nolcclighting.no.24nb4.srv.ip.no/images_hovedside/thorlux-light-line... · THORLUX LIGHT LINE Continuous suspended direct/indirect

l Extruded aluminium finished light textured silver (RAL 9006)l Sections supplied assembled for rapid installation using easily adjustable wire suspensions, and fitted plug and socket connectionsl 1 x 20W CDM-Tm spotlight optionl Emergency Scanlight AT LED optionl Fitted with 4000K lamp(s)

ACCESSORIES

APPROX. DESCRIPTION CAT. No. kg

End kit 2 ends per kit LL 13360 1.3

Surface wiring tidy LL 13361 0.4

Corner joint kit LL 14285 4.0

Infill to infill / infill to joint link kit LL 14762 0.2

DIMENSIONS

INFILL SECTIONS

LENGTH APPROX. APPROX. 1 x 20W APPROX. (mm) PLAIN kg SCANLIGHT AT kg CDM-Tm SPOT s kg

750 LL 13356 2.3 LL 13434 2.9 LL 13467 3.1

1000 LL 13357 3.0 LL 13435 3.6

1269 LL 13358 3.5 LL 13436 4.1

1569 LL 13359 4.3 LL 13437 4.9 LL 13468 5.1

Continuous system consists of luminaires joined with an infill section (see table) or link kit and each run is finished with an end kit. Scanlight AT infill sections include a 3W LED Downlighter for emergency use. Interconnecting wiring allows control and communication.

Infill section comprises:Appropriate length of infill, interconnecting wiring, cover lid, fasteners and wire suspension.

End kit comprises:Two die-cast ends, one wire suspension, one 8 core supply cable with fitted plugs.

INFORMATION

750 / 1000 / 1269 / 1569

165

40

1 x 20WCDM-Tm

49

Scanlight ATversion only

Infills available with one fully adjustable spotlight using a

high efficiency, long life 20W CDM-Tm 3000K lamp (15min. hot re-strike). Electronic gear

and lamps fitted.

Infill sections THORLUX LIGHT LINE

IP20 T5

SPECIFICATION

Scanlight AT Emergency LED version

Web Link: Scanlight AT System

Dec ‘12 www.thorlux.com/suspended 75

sCannot be switched independently from luminaire

Page 7: THORLUX LIGHT LINE - lcclighting.no.24nb4.srv.ip.nolcclighting.no.24nb4.srv.ip.no/images_hovedside/thorlux-light-line... · THORLUX LIGHT LINE Continuous suspended direct/indirect

PHOTOMETRIC GUIDE SURFACE WIRING TIDY

TRANSVERSE AXIAL

CANDELAS PER 1000 LUMENS

80

160

240

320

80

TRANSVERSE AXIAL

CANDELAS PER 1000 LUMENS

80

160

240

320

80

1 x 28W D.L.O.R. 74% U.L.O.R. 20%

FACTOR: 1 x 35W = 0.95 1 x 49W = 0.87

2 x 28W D.L.O.R. 50% U.L.O.R. 27%

FACTOR: 2 x 35W = 1.00 2 x 49W = 0.99

4 = 1 -10V or Motionline5 = 1 -10V or Motionline6 = Scanlight AT DALI7 = Scanlight AT DALI

1 = Switched live2 = NeutralE = Earth3 = Un-switched live

Cable from luminaire Cable to mains

ACCESSORY DIMENSIONS

JOINT KITS - Continuous use only

Scanlight

40 56

165

1 x CDM-Tm Spot

4087

91

165

87dia.

Corner Joint Kitcontinuous use only

End Kit

40

16544

Link Kit

40

16540

Wiring Tidy

34

15583

665

665

165

Photometric Guide and Accessories

Corner Joint Crossover Joint Tee Joint

433

165

433

700

165

433

700

165700

APPROX. DESCRIPTION CAT. No. kg

Corner joint LL 14285 2.3

Corner joint (powered) LL 14286 2.8

Crossover joint LL 13599 4.3

Tee joint LL 13600 3.9

Certain configurations require powered corners. Please contact our Technical Department for further information.

76 www.thorlux.com/suspended Dec ‘12

Page 8: THORLUX LIGHT LINE - lcclighting.no.24nb4.srv.ip.nolcclighting.no.24nb4.srv.ip.no/images_hovedside/thorlux-light-line... · THORLUX LIGHT LINE Continuous suspended direct/indirect

TYPICAL SUSPENSION OPTIONS

Individual Luminaire- see page 73

Continuous Luminaire- see page 74

End Kit- 2 ends per kit

Link Kit- see page 74

In�ll Section- see page 75

Standardsuspension:maximum

drop 3.14m

Suggestedminimum

0.5m

Supply to oneend only

SLIDING SUSPENSIONCONTINUOUS ROWS USING SLIDING SUSPENSION

250 250

250 250 250

250 250

250 250 250

Sliding suspensions should be located a maximum of 250mm from either end.

Sliding suspension kits should be located a maximum of 250mm either side of joints or from ends. Maximum recommended centres 2.0 metres.

THORLUX LIGHT LINE