This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program
Prepared by
Energy Efficiency through Product & Process
Design
Prepared by Plastics Industry Manufacturers of Australia (PIMA) in partnership with Australian Management Academy (AMA);
executed in collaboration with EcoProducts
![Page 2: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/2.jpg)
Copyright and disclaimer
The Office of Environment and Heritage and the State of NSW are pleased to allow this material to be used, reproduced and adapted, provided the meaning is unchanged and its source, publisher and authorship are acknowledged.
The Office of Environment and Heritage has made all reasonable effort to ensure that the contents of this document are factual and free of error. However, the State of NSW and the Office of Environment and Heritage shall not be liable for any damage which may occur in relation to any person taking action or not on the basis of this document.
Office of Environment and Heritage, Department of Premier and Cabinet
Phone: (02) 9995 5000 (switchboard)
Email: [email protected]
Website: www.environment.nsw.gov.au
2
![Page 3: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/3.jpg)
Energy Efficiency through Product & Process
Design
Module 8 – Energy Efficient Manufacturing Process Design
© Australian Management Academy and Eco Products Agency
3
![Page 4: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/4.jpg)
Key Points
1. Saving energy through process design
2. Designing energy efficient processes
3. Energy efficient process equipment
4© Australian Management Academy and Eco Products Agency
![Page 5: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/5.jpg)
Saving Energy through Process Design
Energy savings can be obtained by process design for new or existing products•Investment in energy efficient equipment•Improvement of existing equipment•Automation
Typically provides 15% energy saving
© Australian Management Academy and Eco Products Agency
5
![Page 6: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/6.jpg)
Energy Saving through Process Design
Energy Cost
$10028%
$72
Process Optimization 15% savingProcess Design 15% savingTOTAL (cumulative) 28% saving
ProductDesign Process
Design ProcessOptimization
6© Australian Management Academy and Eco
Products Agency
![Page 7: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/7.jpg)
Designing Energy Efficient Processes
1. Understand where energy is being used
2. Measure energy use
3. Analyze energy use
4. Compare to benchmarks
5. Identify opportunities
© Australian Management Academy and Eco Products Agency
7
![Page 8: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/8.jpg)
Designing Energy Efficient Processes
• Where will energy being used?• What will the energy be used for?• How much energy will be used?• Can it be used more efficiently?• Could energy be supplied more efficiently?• Where is energy being wasted?• Can waste energy be reduced?• Can waste energy be recovered?
8© Australian Management Academy and Eco Products
Agency
![Page 9: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/9.jpg)
System Design
• Looking at the whole energy use of a plant back to the primary energy sources to identify environmental impact
• system efficiency = 60% x 95% x 35% = 20%
• primary energy use is 5 times applied energy9
© Australian Management Academy and Eco Products Agency
![Page 10: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/10.jpg)
Primary Processes
Pick the most energy efficient primary process option:
– injection– extrusion + cutting + assembly– sheet extrusion + thermoforming + trimming
10
© Australian Management Academy and Eco Products Agency
![Page 11: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/11.jpg)
Primary Processes
Integrate processes to avoid extra heating/cooling cycles:
– Direct sheet extrusion/thermoforming– Direct compounding/injection– Requires high volumes to justify high capital
11© Australian Management Academy and Eco Products
Agency
![Page 12: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/12.jpg)
Example
Peguform GmbH– Automotive door module– Compounding + Injection moulder with integrated
foamed in place PU gasket– 300 MWh/year energy saving– Additional savings from logistics simplification
12© Australian Management Academy and Eco Products Agency
![Page 13: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/13.jpg)
Primary Process
13© Australian Management Academy and Eco Products Agency
![Page 14: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/14.jpg)
Primary Processes
• Use the right size process– Minimum size machine for the required output
• Clamp tonnage• Injection unit size• Extruder screw diameter• Dryer size
• Multi-cavity tooling can increase energy efficiency
14© Australian Management Academy and Eco Products
Agency
![Page 15: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/15.jpg)
Primary Processes
But it may be more efficient to run a larger machine slower than a smaller machine ‘flat-out’
30% GF PA-6 compounded at 2,100 kg/h
15© Australian Management Academy and Eco Products
Agency
![Page 16: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/16.jpg)
Electric Injection Moulders
• Electric servo injection moulding machines use much less energy than hydraulic machines
16© Australian Management Academy and Eco Products Agency
![Page 17: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/17.jpg)
Electric Injection Moulders
• Typical energy savings of 30% - 60%– No hydraulic pump operating continuously– No cooling for hydraulic system– Simultaneous movements allow faster cycles– High accuracy may reduce rejects– Lower peak demand
• Capital cost is higher
17© Australian Management Academy and Eco Products
Agency
![Page 18: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/18.jpg)
Electric Injection Moulders
Application exampleEnergy Saving
Medical product (inhaler) 58%
Medical component product (in polystyrene)
60%
Automotive connectors 33% – 66%
Cap (stack tool) 28% – 64%
Flower pot 40%
18© Australian Management Academy and Eco Products
Agency
![Page 19: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/19.jpg)
Example
Gerresheimer AG Medical Plastics Systems Division, Pfreimd, Germany– Replaced 15 hydraulic injection moulding machines
with all-electric machines.– Saving 900 MWh of electricity per year.– Co-generation plant installed to save 28% of primary
energy consumption.– Heat recovery systems installed on compressors at
several plants
19© Australian Management Academy and Eco Products Agency
![Page 20: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/20.jpg)
Other Developments
• Integrated energy monitoring– E.g. Krauss Maffei Energy Analysis Tool
instantaneously logs machine energy consumption
• Energy regeneration from braking force– E.g. Wittmann Battenfeld EcoPower system uses
braking energy for barrel heating
20© Australian Management Academy and Eco Products
Agency
![Page 21: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/21.jpg)
Secondary Processes
• Integrate primary and secondary processes– Insert moulding vs moulding + assembly– Low pressure moulding with surface materials– In-Mould Decoration
• Avoid packing, moving, storing, unpacking
• Also requires high volumes to justify high capital
21© Australian Management Academy and Eco Products
Agency
![Page 22: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/22.jpg)
Secondary Processes
• Painting & coating processes– Drying ovens and tunnels can be high energy users– Gas may be more efficient than electric heating– Infra-red or halogen lamps with tailored emission
spectrum can be more efficient than convection heating
– 'Effects' materials
22© Australian Management Academy and Eco Products Agency
![Page 23: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/23.jpg)
Electric Motors
• Electric motors are most efficient when operated near rated load– Don’t over-design with oversized motors
• High-efficiency motors 2–3% more efficient– Always worth the extra cost for energy savings
23© Australian Management Academy and Eco Products Agency
![Page 24: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/24.jpg)
Electric Motors
24© Australian Management Academy and Eco Products Agency
![Page 25: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/25.jpg)
Electric Motors
• AC motors are more efficient than DC motors• AC motors run at a speed set by the electricity
supply frequency (50 Hz)
25© Australian Management Academy and Eco Products
Agency
![Page 26: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/26.jpg)
Variable Speed Drives
• Can be used on most motor driven equipment• Allows speed of AC motors to be varied• Variable Speed Drives (VSD) can give 50%
energy savings on motors drives
26© Australian Management Academy and Eco Products Agency
![Page 27: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/27.jpg)
Variable Speed Drives
• Hydraulic pumps on injection moulding machines run continuously and have excess capacity to meet peak demand
• Pump still draws 50% - 75% of rated power under low load
• VSDs can reduce the pump speed when demand is low
27© Australian Management Academy and Eco Products Agency
![Page 28: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/28.jpg)
Automation
• Process automation can save energy– Faster cycling– Better reproducibility– Less downtime– Process integration
Automated clip insert loading
28© Australian Management Academy and Eco Products Agency
![Page 29: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/29.jpg)
Example
AGRU Kunstofftechnik GmbH– Pipe extrusion plant with up to 15 diameter
changes per week– Installed Krauss Maffei
QuickSwitch System– 100 MWh/year electricity
saving due to reduced
change-over time
29© Australian Management Academy and Eco Products Agency
![Page 30: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/30.jpg)
Dryers
• Drying is a major energy consumer– 30% of energy use in PET processing
• New technologies use less energy– Moretto Flowmatik
• Zeolite drying uses less energy for regeneration• Controls minimize airflow
– Maguire Low Pressure Dryer• Vacuum assists moisture removal• Claim 70-80% energy saving, 6 x faster
30© Australian Management Academy and Eco Products Agency
![Page 31: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/31.jpg)
Dryers
• Eliminate or minimize energy use for drying
• Use dry material from sealed bags• Use correctly sized, energy efficient driers• Do not over-dry. Minimize time & temperature
31© Australian Management Academy and Eco Products Agency
![Page 32: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/32.jpg)
Granulators
• Are they needed? – Hot runners can eliminate
• Design granulators correctly– Use correctly sized equipment– Granulate sprues, runners & cut-offs immediately– Avoid off-line granulating– Avoid cooling, then re-drying and re-heating– Turn off granulators when not operating
32© Australian Management Academy and Eco Products Agency
![Page 33: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/33.jpg)
Compressors
• Compressed air is an expensive energy source• Find an alternative• Systems need correct design
– Compressor selection– Reservoir size– Distribution pipes
• Variable speed and variable displacement compressors can provide good savings
33© Australian Management Academy and Eco Products Agency
![Page 34: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/34.jpg)
Cooling Systems
• Design cooling systems for energy efficiency– Chillers can use a significant amount of process
energy– Design cooling channels in tools properly to increase
thermal transfer and reduce pressure loss– Very low tool temperatures may not speed up cycle
times for thick wall parts
34© Australian Management Academy and Eco Products Agency
![Page 35: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/35.jpg)
Cogeneration
• On-site generation of electricity plus heat and chilled water (tri-generation)
35© Australian Management Academy and Eco Products Agency
![Page 36: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/36.jpg)
Cogeneration
• Widely used in Europe– EU 20% target for 2010– Up to 50% in Scandinavia
• Low penetration in Australia– About 5% (1.5% in sugar industry)– High capital and operating cost– Higher electricity cost vs grid– Need demand for heat energy
36© Australian Management Academy and Eco Products Agency
![Page 37: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/37.jpg)
Cogeneration
• But becoming more viable– Plant costs and operating costs are reducing– Gas cost vs rising electricity cost– Absorption chillers provide chilled water
efficiently– Energy companies will supply and operate
EPA Melbourne trigen plant386 kW electrical power290 kW chilled water230 kW hot waterEst. 80% thermal efficiency
37© Australian Management Academy and Eco Products Agency
![Page 38: This project has been assisted by the New South Wales Government through its Energy Efficiency Training Program Prepared by Energy Efficiency through Product](https://reader030.vdocuments.us/reader030/viewer/2022032800/56649d315503460f94a0a13f/html5/thumbnails/38.jpg)
Summary
• There are significant opportunities for energy saving through process design
• Process design should use a systematic approach to achieve energy efficiency
• Many new technologies offer energy savings
38© Australian Management Academy and Eco Products