this presentation premiered at watersmart …...energy intensity (ei) – kwh/af – average amount...
TRANSCRIPT
![Page 1: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/1.jpg)
This presentation premiered at WaterSmart Innovations
watersmartinnovations.com
![Page 2: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/2.jpg)
Water System Embedded Energy Mapping
![Page 3: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/3.jpg)
Presentation Agenda
1. Introduction and Background2. The Water-Energy Nexus3. Embedded Energy Plan4. Next Steps
![Page 4: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/4.jpg)
Introduction and Background
![Page 5: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/5.jpg)
District Overview
330,000 Residential Customers 500,000 Daytime Population110,734 Service Connections 6 Cities plus unincorporated OC181 Square Miles 20% of Orange County 27 Drinking Water Wells1516 Miles Drinking Water Pipelines 36 Drinking Water Reservoirs487 Miles Recycled Water Pipelines 2 Recycled Water Treatment Plants987 Miles Sewage Collection Pipelines 13 Urban Runoff Treatment Sites
4
![Page 6: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/6.jpg)
The Water-Energy Nexus
![Page 7: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/7.jpg)
The Water-Energy Nexus in California
• ~8% of California’s electricity use is for providing water services (US average ~4%)
Non-Water related uses
80.9%
Customer End Uses~11.4%
Water Infrastructure
7.7%
Water-Related
Uses~19.1%
California Statewide Electricity Use
6.4%
0.1% 0.4%0.8%
WastewaterCollection andTreatmentDistributionPumping
PotableTreatment
Supply andConveyancePumps
6
![Page 8: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/8.jpg)
Where Does Southern California Get Its Water?
Local Supplies Groundwater & Recycling
Local SuppliesLA Aqueduct
Conservation
Colorado River Aqueduct700,000 AF
State WaterProject
Entitlement2 Million AF
Transfers & StorageGroundwater Banking
Conversion: 1 acre-foot (AF) = 325,851 gallons
![Page 9: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/9.jpg)
66%
9%
11%
14%
Imported WaterClear GroundwaterLocal Surface WaterRecycled Water
ImportedWater
Population Served: 114,000 Total Water Provided: 40,492 AF
23%
27%28%
21%
Imported WaterClear GroundwaterLocal Surface WaterRecycled WaterTreated Groundwater
1990 2014
Imported Water
Population Served: 374,000 Total Water Provided: 99,495 AF
IRWD Water Supply Portfolio
8
![Page 10: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/10.jpg)
Energy Intensity and Embedded Energy
• Energy Intensity (EI) – kWh/AF– Average amount of energy needed to
transport or treat water or wastewater on a per unit basis (kWh/AF).
– Associated with a particular facility– EIs of facilities can be aggregated to
represent total EI of water service.• Energy Embedded in Water – kWh
– Captures the entire energy picture both upstream and downstream of an end use customer
– Useful in quantifying energy savings as a result of water savings (water saved x EI = embedded energy saved)
Illustrative Energy Intensity Calculation for a Pump
V = Volume PumpedE = Energy
Water
VEEI =
Embedded Energy
Wastewater System
Customer
Potable WaterSystem
Energy Use = Embedded Energy
9
![Page 11: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/11.jpg)
California Public Utilities Commission Activities
• Past CPUC Water Energy Nexus Studies:– Wholesale Supply System Energy Use– Retail System Energy Use– Water-Energy Nexus Pilots
• Current CPUC Direction– Consider allowing energy and water utilities to fund
joint water-energy nexus programs– Tools and calculators to quantify embedded energy
savings– Tools can be customized for specific water utilities
10
![Page 12: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/12.jpg)
Embedded Energy Plan
11
![Page 13: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/13.jpg)
Goals
• Demonstrate embedded energy reductions over time
• Quantify the avoided cost of energy in water conservation programs
• Identify the most cost-effective geographic areas for water conservation programs
• Provide information required to develop a pumping surcharge recommendation
• Position IRWD for the possibility of obtaining energy utility funding for water conservation programs
12
![Page 14: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/14.jpg)
Methodology
Source Water Supply
Potable Water
Treatment
Potable Water
Distribution
Non-Potable Water
Distribution
Recycled Water
Treatment
Sewage Collection
Sewage Treatment
Sewage Discharge
End Use Customers
Biosolids Treatment
Biosolids Disposal
IRWD Admin.
Facilities
13
![Page 15: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/15.jpg)
Methodology
• Generate Base Data– Collect, clean and
analyze historic energy and water
– Link energy data to water data
– Map flow of water through each facility to regions
• Use Base Data for: – Geospatial analysis of
energy use and energy intensity
– Embedded energy savings from conservation
– Energy cost analysis– Forecast future energy
use
14
![Page 16: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/16.jpg)
Common Challenges
• Data availability – Water and energy data for the same periods of time– Missing/incomplete data
• Linking energy data sets to water flow data– Often managed/tracked separately – Not always a clear link based on addresses or facility
names• Reconciling flow data
– metered at the facility vs…– total billed to customers vs…– system demand forecast models
15
![Page 17: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/17.jpg)
Results – Historic System Energy Use
16
![Page 18: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/18.jpg)
Top 12 Energy Consuming Facilities (kWh/AF)
17
![Page 19: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/19.jpg)
Results – Historic Water Conservation Activity
18
![Page 20: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/20.jpg)
Results – Embedded Energy Savings from Conservation
Results in $260,000 annual energy bill savings
19
![Page 21: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/21.jpg)
Results –Geospatial EI
• Map energy intensity, pumping cost, water use by customer type
• Allows for geographic targeting of programs
• Dynamic, GIS-based tool
20
![Page 22: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/22.jpg)
Results – GIS Tool
21
![Page 23: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/23.jpg)
GIS Tool
• Map Water Use
• Identify areas of high use
• Isolate by type of customer (i.e. landscape)
22
![Page 24: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/24.jpg)
GIS Tool
• Map Energy Intensity
• Identify areas of high EI
• Select systems (treatment, distribution, etc.)
23
![Page 25: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/25.jpg)
GIS Tool
• Conservation Analysis
• Select high use regions
• Estimate water and energy savings from targeted conservation in selected region
24
![Page 26: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/26.jpg)
Next Steps
![Page 27: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/27.jpg)
Where IRWD Goes From Here
• Incorporate Avoided Cost for Embedded Energy in Water Conservation Program Planning
• Identify and Track Energy Efficiency Improvements • Potential Pilot Program with Local Energy Providers
![Page 28: This presentation premiered at WaterSmart …...Energy Intensity (EI) – kWh/AF – Average amount of energy needed to transport or treat water or wastewater on a per unit basis (kWh/AF)](https://reader030.vdocuments.us/reader030/viewer/2022040819/5e66cb71eb79fa4dd21b4d83/html5/thumbnails/28.jpg)
Contact Information
Amy McNultyWater Efficiency Manager, IRWD949-453-5634 [email protected]
Amul SatheAssociate Director, Navigant [email protected]
27