This electronic collection of documents is provided
for the convenience of the user
and is Not a Certified Document –
The documents contained herein were originally issued
and sealed by the individuals whose names and license
numbers appear on each page, on the dates appearing
with their signature on that page.
This file or an individual page
shall not be considered a certified document.
![Page 2: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/2.jpg)
RIP RAP DETAIL
NOT TO SCALE
GROUND LINE
NORMAL TO CAP
MI
N.1'-0'' MIN. EARTH BERM
NORMAL TO CAP
1'-7'' MIN. BERM
3'-
6''
2'-
0''
1'-
0''
SLOPE 1 • : 1
NOT TO SCALE
RIP RAP DETAIL
DRAINAGE
GEOTEXTILE FOR
SECTION TAKEN AT RIGHT ANGLE TO -L-
UNCLASSIFIED STRUCTURE EXCAVATION
SECTION ALONG -L-
PLAN
R
NO
033730
SEAL
RTH CA OLIN
A
LA
NOISSEFO
RP
ENGINEE
R
C.A
N
NA
TEAGU
E
{ -L-
PT STA. 13+74.38 -L-
STA. 12+71.37 -L-
BEGIN APPROACH SLAB
STA. 13+79.67 -L-
BEGIN FRONT SLOPE
STA. 13+80.66 -L-
END APPROACH SLAB
STA. 12+82.20 -L-
W.P. #1
ST
A. 12
+90.4
5 -
L-
ST
A. 12
+53.8
5 -
L-
ST
A. 13
+97.1
3 -
L-
ST
A. 13
+63.0
6 -
L-
END BENT 1
FILL FACE @
10/14
10/14
ARE THE AS-BUILT PLANS
I HEREBY CERTIFY THESE PLANS
STA. 13+69.80 -L-
W.P. #2
STA. 13+26.00 -L-
{ BRIDGE
EL. 518.89 (NORMAL TO CAP)
1'-0" MIN. EARTH BERM
EL. 518.37 (NORMAL TO CAP)
1'-0" MIN. EARTH BERM
EL. 517.28 (NORMAL TO CAP)
1'-0" MIN. EARTH BERM
EL. 516.74 (NORMAL TO CAP)
1'-0" MIN. EARTH BERM
STA. 12+72.58 -L-
BEGIN FRONT SLOPE
13+00 14+00
500
510
520
530
540
SPAN A
PROPOSED GRADE
END BENT 1 END BENT 2
G.P. EL. 525.63
STA. 12+72.58 -L-
BEGIN FRONT SLOPE
G.P. EL. 525.69
STA. 12+82.20 -L-
FILL FACE @ END BENT 1
(NORMAL TO CAP)
1'-7" MIN. BERM (TYP.)
(TYP.)
1'-0"
PILES (TYP.)
HP 12X53 STEEL
(NORMAL TO CAP) (TYP.)
1'-0" MIN. EARTH BERM
MI
N.
3'-
6"
(TY
P.)
GROUND LINE
EXISTING
APPROXIMATE
G.P. EL. 526.21
STA. 13+69.80 -L-
FILL FACE @ END BENT 2
G.P. EL 526.27
STA. 13+79.67 -L-
BEGIN FRONT SLOPE
2'-0" (TYP)
CAP) (TYP.)
(NORMAL TO
1•:1 SLOPE
GRADE DATA -L-
(FIX.)(FIX.)
(+)0.5934%(-)7.8854%
EL. 520.8
WATER SURFACE
DESIGN HIGH
EL. 521.52
WATER SURFACE
BASE DISCHARGE (Q100)
(03/13/14)
EL. 512.4 |
SURFACE
NORMAL WATER
GRADE DATA -L-
(+)3.7969%(+)0.5934%
D
PI STA. 11+87.76
L = 374.39'
T = 187.76'
R = 1,960.00'
550
VC = 228.00'
EL. = 524.81
PI STA. = 11+34.00
RIP RAP (TYP.)
CLASS II
13+50
VC = 126.00'
EL. = 527.32
PI STA. = 15+57.00
S-1
16
12+50
43'-9Œ"
43'-9Œ"
87'-7„" (FILL FACE @ END BENT 1 TO FILL FACE @ END BENT 2 ALONG WORKLINE)
RIP RAP (TYP.)
CLASS II
(TYP.)
SUBSTRUCTURE
EXISTING
N 37°06'06" E
13+0014+00
WI
CK
ER
BR
AN
CH
TO SR 1939
TO SR 1941
HORIZONTAL CURVE DATA -L-
LONG CHORD
END BENT 2
FILL FACE @
EL. 518 |
EL. 520 |
SUBSTRUCTURE (TYP.)
EXISTING
EL. 512 |EL. 512 |
EL. 512 |
EL. 520 |
EL. 518 |
EL. 515 |
(TYP.)
GEOTEXTILE FOR DRAINAGE
M. SELLS
A. TEAGUE
10/14
10/14
A. TEAGUE
E. NOLTING
NO. NO.BY: BY:DATE: DATE:
REVISIONS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
4
SHEET
NO.
TOTAL
SHEETS
TI
ME:
DA
TE:
FI
LE:
Div
12
LI
BR.t
bl
2/9/2016
MS
EL
LS
7:4
3:2
2
AM
PE
NT
AB
LE:
US
ER:
North_
Carolina_
De
pt_of
_Transportatio
n\
NC
DO
T_2012_2014_
OC_
Div
_LS
C_
M\
NC
DO
T_17
BP_10_
TO_3c\06.0
0_
TI
P_Fold
er_Structure\17
BP.1
0.R.7
1 Unio
n #122
Belk
Mill Rd\
Structures\
CA
D\
Unio
n122_S
D_
GD_01.d
gn
PL
OT
DRI
VE
R:
NC
DO
T_pdf
_m
ono
_e
ng_50.plt
GENERAL DRAWING
SHEET 1 OF 2
UNION
13+26.00 -L-
REPLACES BRIDGE NO. 122
OVER WICKER BRANCH
BRIDGE ON SR 1940
17BP.10.R.71
DES CHK:
DES BY:
DATE :
DATE : DWG BY:
CHK BY: DATE :
DATE :
UNLESS ALL SIGNATURES COMPLETED
DOCUMENT NOT CONSIDERED FINAL
HDR Engineering, Inc. of the Carolinas
555 Fayettville St., Suite 900 Raleigh, N.C. 27601
N.C.B.E.L.S. License Number: F-0116
DocuSign Envelope ID: 2B987909-5B01-4C7E-BD93-C518EB559907
2/9/2016
![Page 3: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/3.jpg)
NOTES:
HYDRAULIC DATA
BASE HIGH WATER ELEVATION
BASE DISCHARGE (Q100)
DRAINAGE AREA
DESIGN HIGH WATER ELEVATION
FREQUENCY OF DESIGN FLOOD
DESIGN DISCHARGE
OVERTOPPING FLOOD DATA
OVERTOPPING FLOOD ELEVATION
FREQUENCY OF OVERTOPPING FLOOD
OVERTOPPING DISCHARGE
S-2
LUMP SUM
SUPERSTRUCTURE
END BENT NO. 1
TOTAL LUMP SUM LUMP SUM
LUMP SUM CU. YDS.
LUMP SUM
LUMP SUM LBS.
TOTAL BILL OF MATERIAL
END BENT NO. 2
NO. LIN. FT. LIN. FT. LUMP SUM
LUMP SUM
TONS
SHEET 2 OF 2
LIN. FT.NO.SQ. YDS.
CONCRETE
CLASS A
STEEL
REINFORCING
RAIL
BARRIER
CONCRETE
VERTICAL
FOR DRAINAGE
GEOTEXTILE
BEARINGS
ELASTOMERIC
R
NO
033730
SEAL
RTH CA OLIN
A
LA
NOISSEFO
RP
ENGINEE
R
C.A
N
NA
TEAGU
E
BOX BEAMS
CONCRETE
PRESTRESSED
3'-0" X 2'-9"
LUMP SUM LUMP SUM
5
5
10
170.00
170.00
10
10
850.0
850.0
STEEL PILES
HP 12 x 53
10/14
10/14
26.7
26.4
53.1
75
75
150
104
203
110
115
225
W.P. #1 W.P. #2
LONG CHORD LAYOUT
FOR HORIZONTAL CURVE DATA)
(SEE GENERAL DRAWING SHEET 1
(END BENTS ARE PARALLEL)
LONG CHORD
{ -L-
ST
A. 12+82.2
0 -L-
FI
LL F
AC
E
@
EN
D
BE
NT #1
ST
A. 13+69.8
0 -L-
FI
LL F
AC
E
@
EN
D
BE
NT #2
R
= 1960.0
0'
= 521.52
= 2259 CFS
= 5.8 SQ. MI.
= 520.8
= 25 YR
= 1600 CFS
= 525.4
= > 500 YR
= 4950 CFS
BENCHMARK: BL-4, 17.34' LT. OF STA. 16+58.67 -L-, EL. = 531.11'
87'-7„" (ALONG LONG CHORD)
120°00'00"120°00'00"
31°16'49"75'-10Š
"
16
-L-
STA. 13+26.00
STRUCTURE AT
EXISTING
REMOVAL OF
-L-
STA. 13+26.00
EXCAVATION AT
STRUCTURE
UNCLASSIFIED
-L-
STA. 13+26.00
SLABS
APPROACH
BRIDGE
10/14
10/14
M. SELLS
A. TEAGUE
A. TEAGUE
E. NOLTING
FOR UTILITY INFORMATION, SEE ROADWAY PLANS.
"REMOVAL OF EXISTING STRUCTURE AT STATION 13+26.00 -L-".
LEAD BASED PAINT SHALL BE INCLUDED IN THE BID PRICE FOR
REGULATIONS PERTAINING TO HANDLING OF MATERIALS CONTAINING
RESULTING FROM COMPLIANCE WITH APPLICABLE STATE OR FEDERAL
TO ARTICLE 107-1 OF THE STANDARD SPECIFICATIONS. ANY COSTS
STEEL CONTAINS LEAD, THE CONTRACTOR'S ATTENTION IS DIRECTED
INASMUCH AS THE PAINT SYSTEM ON THE EXISTING STRUCTURAL
EVALUATING SCOUR AT BRIDGES".
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH "HEC 18,
ROADWAY PLANS.
ASPHALT WEARING SURFACE IS INCLUDED IN ROADWAY QUANTITY ON
FOR EROSION CONTROL MEASURES, SEE EROSION CONTROL PLANS.
AT END BENT NO. 2.
CONCRETE OR GROUT IS REQUIRED TO FILL HOLES FOR PILE EXCAVATION
EXCAVATION, SEE SECTION 450 OF THE STANDARD SPECIFICATIONS.
EXCAVATE HOLES AT PILE LOCATIONS TO ELEVATION 509.5 FT. FOR PILE
PILE EXCAVATION IS REQUIRED TO INSTALL PILES AT END BENT NO. 2.
OF 208 TONS PER PILE.
DRIVE PILES AT END BENT NO. 2 TO A REQUIRED DRIVING RESISTANCE
OF 125 TONS PER PILE.
PILES AT END BENT NO. 2 ARE DESIGNED FOR A FACTORED RESISTANCE
IN SOIL
EXCAVATION
PILE
LIN. FT.
70 20
LIN. FT.
NOT IN SOIL
EXCAVATION
PILE
6
1431
39 99
(2'-0" THICK)
CLASS II
RIP RAP
3,724
3,692
7,416
ASSESSMENT
ASBESTOS
LUMP SUM
LUMP SUM
UNLESS ALL SIGNATURES COMPLETED
DOCUMENT NOT CONSIDERED FINAL
HDR Engineering, Inc. of the Carolinas
555 Fayettville St., Suite 900 Raleigh, N.C. 27601
N.C.B.E.L.S. License Number: F-0116
AT END BENT NO. 1.
CONCRETE OR GROUT IS REQUIRED TO FILL HOLES FOR PILE EXCAVATION
EXCAVATION, SEE SECTION 450 OF THE STANDARD SPECIFICATIONS.
EXCAVATE HOLES AT PILE LOCATIONS TO ELEVATION 509.0 FT. FOR PILE
PILE EXCAVATION IS REQUIRED TO INSTALL PILES AT END BENT NO. 1.
OF 208 TONS PER PILE.
DRIVE PILES AT END BENT NO. 1 TO A REQUIRED DRIVING RESISTANCE
OF 125 TONS PER PILE.
PILES AT END BENT NO. 1 ARE DESIGNED FOR A FACTORED RESISTANCE
FOR PILES, SEE SECTION 450 OF THE STANDARD SPECIFICATIONS.
BE REDUCED AS FOUND NECESSARY DURING THE LIFE OF THE PROJECT.
OF THE PROPOSED BRIDGE, A LOAD LIMIT MAY BE POSTED AND MAY
INTEGRITY OF THE BRIDGE DETERIORATE DURING CONSTRUCTION
BRIDGE IS PRESENTLY POSTED FOR LOAD LIMIT. SHOULD THE STRUCTURAL
LOCATED AT THE PROPOSED SITE SHALL BE REMOVED. THE EXISTING
CAPS, POSTS, AND SILLS, WITH TIMBER CAP AND PILE CRUTCHES, AND
TIMBER DECK ON I-BEAMS AND A CLEAR ROADWAY OF 19'-2" ON TIMBER
THE EXISTING STRUCTURE CONSISTING OF 1 SPAN (1 @ 40'-8") WITH A
ON THE PLANS AND THE ACTUAL CONDITIONS AT THE PROJECT SITE.
ON DIFFERENCES BETWEEN THE EXISTING BRIDGE SUBSTRUCTURE SHOWN
TRANSPORTATION FOR ANY DELAYS OR ADDITIONAL COST INCURRED BASED
SHALL HAVE NO CLAIM WHATSOEVER AGAINST THE DEPARTMENT OF
IS SHOWN FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR
IS FROM THE BEST INFORMATION AVAILABLE. THIS INFORMATION
THE SUBSTRUCTURE OF THE EXISTING BRIDGE INDICATED ON THE PLANS
SEE SECTION 412 OF THE STANDARD SPECIFICATIONS.
CONTRACT LUMP SUM PRICE FOR UNCLASSIFIED STRUCTURE EXCAVATION.
DIRECTED BY THE ENGINEER. THIS WORK WILL BE PAID FOR AT THE
FOR A DISTANCE OF 20 FT. EACH SIDE OF CENTERLINE ROADWAY AS
THE MATERIAL SHOWN IN THE CROSS-HATCHED AREA SHALL BE EXCAVATED
ACCORDANCE WITH ARTICLE 402-2 OF THE STANDARD SPECIFICATIONS.
REMOVE THE BRIDGE AND SUBMIT PLANS FOR DEMOLITION IN
TO ALLOW DEBRIS TO FALL INTO THE WATER. THE CONTRACTOR SHALL
REMOVAL OF THE EXISTING BRIDGE SHALL BE PERFORMED SO AS NOT
ACTIVITIES, SEE SPECIAL PROVISIONS.
FOR ASBESTOS ASSESSMENT FOR BRIDGE DEMOLITION AND RENOVATION
FOR GROUT FOR STRUCTURES, SEE SPECIAL PROVISIONS.
FOR CRANE SAFETY, SEE SPECIAL PROVISIONS.
FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS.
FOR SUBMITTAL OF WORKING DRAWINGS, SEE SPECIAL PROVISIONS.
THIS BRIDGE IS LOCATED IN SEISMIC ZONE 1.
AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS.
THIS BRIDGE HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FOR OTHER DESIGN DATA AND GENERAL NOTES, SEE SHEET SN.
ASSUMED LIVE LOAD = HL-93 OR ALTERNATE LOADING.
NO. NO.BY: BY:DATE: DATE:
REVISIONS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
4
SHEET
NO.
TOTAL
SHEETS
TI
ME:
DA
TE:
FI
LE:
Div
12
LI
BR.t
bl
2/9/2016
MS
EL
LS
8:3
6:5
9
AM
PE
NT
AB
LE:
US
ER:
North_
Carolina_
De
pt_of
_Transportatio
n\
NC
DO
T_2012_2014_
OC_
Div
_LS
C_
M\
NC
DO
T_17
BP_10_
TO_3c\06.0
0_
TI
P_Fold
er_Structure\17
BP.1
0.R.7
1 Unio
n #122
Belk
Mill Rd\
Structures\
CA
D\
Unio
n122_S
D_
GD_02.d
gn
PL
OT
DRI
VE
R:
NC
DO
T_pdf
_m
ono
_e
ng_50.plt
GENERAL DRAWING
UNION
13+26.00 -L-
OVER WICKER BRANCH
BRIDGE ON SR 1940
17BP.10.R.71
DES CHK:
DES BY:
DATE :
DATE : DWG BY:
CHK BY: DATE :
DATE :
UNLESS ALL SIGNATURES COMPLETED
DOCUMENT NOT CONSIDERED FINAL
HDR Engineering, Inc. of the Carolinas
555 Fayettville St., Suite 900 Raleigh, N.C. 27601
N.C.B.E.L.S. License Number: F-0116
DocuSign Envelope ID: 2B987909-5B01-4C7E-BD93-C518EB559907
2/9/2016
![Page 4: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/4.jpg)
1.117 0.247 1.93 A EL 41.634 0.625 1.12 A EL 8.327 0.247 1.56 A EL 41.634
1.448 0.247 2.50 A EL 41.634 0.625 1.45 A EL 8.327 -- -- -- -- --
1.448 52.140 0.247 2.59 A EL 41.634 0.625 1.45 A EL 8.327 0.247 2.09 A EL 41.634
1.877 67.589 0.247 3.35 A EL 41.634 0.625 1.88 A EL 8.327 -- -- -- -- --
4.378 59.102 0.247 7.48 A EL 41.634 0.625 4.38 A EL 8.327 0.247 4.84 A EL 41.634
3.091 61.822 0.247 5.50 A EL 41.634 0.625 3.09 A EL 8.327 0.247 3.56 A EL 41.634
2.861 62.937 0.247 5.17 A EL 41.634 0.625 2.86 A EL 8.327 0.247 3.35 A EL 41.634
2.183 59.498 0.247 3.72 A EL 41.634 0.625 2.18 A EL 8.327 0.247 2.41 A EL 41.634
1.797 62.749 0.247 3.08 A EL 41.634 0.625 1.80 A EL 8.327 0.247 1.99 A EL 41.634
1.812 64.409 0.247 3.01 A EL 41.634 0.625 1.81 A EL 8.327 0.247 1.95 A EL 41.634
1.647 65.797 0.247 2.75 A EL 41.634 0.625 1.65 A EL 8.327 0.247 1.78 A EL 41.634
67.634 0.247 2.62 A EL 41.634 0.625 1.61 A EL 8.327 0.247 1.70 A EL 41.634
1.965 64.845 0.247 3.35 A EL 41.634 0.625 1.97 A EL 8.327 0.247 2.17 A EL 41.634
1.922 63.556 0.247 3.36 A EL 41.634 0.625 1.92 A EL 8.327 0.247 2.18 A EL 41.634
1.701 70.755 0.247 2.74 A EL 41.634 0.625 1.70 A EL 8.327 0.247 1.77 A EL 41.634
70.125 0.247 2.75 A EL 41.634 0.625 1.67 A EL 8.327 0.247 1.78 A EL 41.634
1.578 66.274 0.247 2.83 A EL 41.634 0.625 1.58 A EL 8.327 0.247 1.83 A EL 41.634
65.773 0.247 2.70 A EL 41.634 0.625 1.53 A EL 8.327 0.247 1.75 A EL 41.634
1.511 68.008 0.247 2.55 A EL 41.634 0.625 1.51 A EL 8.327 0.247 1.65 A EL 41.634
1.456 65.508 0.247 2.52 A EL 41.634 0.625 1.46 A EL 8.327 0.247 1.63 A EL 41.634
60° SKEW & 120° SKEW
85’ BOX BEAM UNIT
LRFR SUMMARY FOR
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
427-JAN-2015 08:51
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_LR_01.dgn
STANDARD
ASSEMBLED BY :
CHECKED BY :
DATE :
DATE :
(NON-INTERSTATE TRAFFIC)
LIMIT STATE
STRENGTH I
DC
1.25
1.00
1.50
1.00
DWg g
SERVICE III
NOTES:
#
1
2
3
* * SEE CHART FOR VEHICLE TYPE
LEGAL LOAD RATING * *
CONTROLLING LOAD RATING
LOAD FACTORS:
I
EL
ER
- INTERIOR GIRDER
- EXTERIOR LEFT GIRDER
- EXTERIOR RIGHT GIRDER
GIRDER LOCATION
DESIGN LOAD RATING (HL-93)
DESIGN LOAD RATING (HS-20)
DESIGN
LOAD
RATING
FACTORS
REQUIRED FOR DESIGN.
ALLOWABLE STRESSES FOR SERVICE III LIMIT STATE ARE AS
SERVICE III LIMIT STATES.
MINIMUM RATING FACTORS ARE BASED ON THE STRENGTH I AND
DRAWN BY : TMG 11/11
CHECKED BY : AAC 11/11
1
2
3
STD. NO. 33LRFR1_60&120S_85L
17BP.10.R.71
UNION
13+26.00 -L-
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
N.D’AIUTO 10/16/14
LE
VE
L
VE
HIC
LE
(TO
NS
)
WE
IGH
T (
W)
LO
AD
RA
TIN
G
CO
NT
RO
LL
ING
(R
F)
RA
TIN
G F
AC
TO
RS
MIN
IMU
M
TO
NS
= W
x R
F
FA
CT
OR
S (
DF
)
DIS
TR
IBU
TIO
N
STRENGTH I LIMIT STATE
SHEARMOMENT
RA
TIN
G F
AC
TO
R
SP
AN
(ft)
LE
FT
EN
D O
F
DIS
TA
NC
E F
RO
M
FA
CT
OR
S (
DF
)
DIS
TR
IBU
TIO
N
RA
TIN
G F
AC
TO
R
SP
AN
(ft)
LE
FT
EN
D O
F
DIS
TA
NC
E F
RO
M
FA
CT
OR
S
LIV
E-L
OA
D
FA
CT
OR
S (
DF
)
DIS
TR
IBU
TIO
N
MOMENT
RA
TIN
G F
AC
TO
R
SP
AN
(ft)
LE
FT
EN
D O
F
DIS
TA
NC
E F
RO
M
CO
MM
EN
T N
UM
BE
R
HL-93 (INVENTORY)
HL-93 (OPERATING)
HS-20 (INVENTORY)
HS-20 (OPERATING)
RATING
LOAD
DESIGN
SNSH
N/A
N/A
36.000
36.000
13.500
1.75
1.35
1.75
1.35
LL
( )
FA
CT
OR
S
LIV
E-L
OA
D
LL
( )
20.000
22.000
34.925
35.550
39.950
42.000
42.000
42.000
41.600
45.000
43.000
33.000
45.000
#
g g
0.80
N/A
0.80
N/A
0.80
LRFR SUMMARY
SERVICE III LIMIT STATE
--
-- -- -- -- --
--------
1
2
--
--
27.250
33.075
GIR
DE
R L
OC
AT
ION
GIR
DE
R L
OC
AT
ION
GIR
DE
R L
OC
AT
ION
SP
AN
SP
AN
SP
AN
SNGARBS2
SNAGRIS2
SNCOTTS3
SNAGGRS4
TNAGRIT3
TNAGRIT4
(S
V)
SIN
GL
E V
EH
ICL
E
(TT
ST
)
TR
UC
K T
RA
CT
OR
SE
MI-
TR
AIL
ERRATING
LOAD
LEGAL
SNS5A
SNS6A
SNS7B
TNT4A
TNT6A
TNT7A
TNT7B
TNAGT5A
TNAGT5B
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
S-3
16
12/5/14M.E.GILES
3
1.610
1.670
1.530
LOAD AND RESISTANCE FACTOR RATING (LRFR) SUMMARY FOR BOX BEAMS
1/27/2015
![Page 5: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/5.jpg)
TYPICAL SECTION
‘‘VERTICAL CONCRETE BARRIER RAIL SECTION’’ DETAIL.
THE PROFILE OF THE GUTTERLINE. FOR RAIL HEIGHT DETAILS AND ASPHALT THICKNESS, SEE THE
BARRIER RAIL AND ASPHALT THICKNESS VARIES WHILE THE TOP OF THE BARRIER RAIL FOLLOWS
THE MAXIMUM BARRIER RAIL HEIGHT AND ASPHALT THICKNESS IS SHOWN. THE HEIGHT OF THE *
(TYP.)
CONST. JT.
GRADE PT.
1"1"
@ {
BR
G.*
3’-0"
1’-0"1’-0"
2’-9"
10 PRESTRESSED CONCRETE BOX BEAM UNITS = 30’-0"
0.040.04
FINAL TENSIONING OF TRANSVERSE STRANDS
ALL ERECTION HAS BEEN COMPLETED AND AFTER
SHEAR KEYS TO BE FILLED WITH GROUT AFTER
15’-0"15’-0"
30’-0"
27’-10" (CLEAR ROADWAY)
13’-11"13’-11"
(T
YP
.)
(SEE ROADWAY PLANS)
ASPHALT WEARING SURFACE
(TYP.)
3� " @ { BRG.
3� " @ { BRG.
3� " @ { BRG.
3’-9
�"
HALF SECTION
THROUGH VOIDS
HALF SECTION
AT INTERMEDIATE DIAPHRAGMS
CONCRETE BARRIER RAIL SECTION’’
FOR DETAILS SEE ‘‘VERTICAL
VERTICAL CONCRETE BARRIER RAIL (TYP.)
POST-TENSIONING STRANDS
L.R. TRANSVERSE
2� " ~ HOLES FOR 0.6" ~
STD. NO. STD.33PCBB1_30
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
4
STANDARD
BOX BEAM UNIT
PRESTRESSED CONCRETE
3’-0" X 2’-9"
SHEET 1 OF 5
16
30-JAN-2015 13:28
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_BX_01.dgn
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
DRAWN BY : DGE 8/11
NOTES
CHECKED BY : TMG 11/11
FIXED END
SECTION AT END BENT
SHEET FOR DETAILS
APPROACH SLAB’’
SEE ‘‘BRIDGE
& #8 DOWELS
À BEARING
SHEETS FOR DETAILS
SEE ‘‘END BENT’’
PREVENT BOND.
ROOFING FELT TO
2 LAYERS OF 30 LB.
BEARING PAD
ELASTOMERIC
VOID
BOX BEAM
SURFACE
WEARING
ASPHALT
1� "
2" ~ BACKER ROD
OPENING
4"
THREADED INSERT DETAIL
REV. 8/14 MAA/TMG
BY CONTRACTOR.
DETERMINED
RECESSED � ". SIZE TO BE
EXTERIOR UNIT AND
CAST IN OUTSIDE FACE OF
PERMITTED THREADED INSERT
2’-3"1
’-3
"1
’-0
"
(SEE NOTES)
2� " � DOWEL HOLES 17BP.10.R.71
13+26.00 -L-
UNION
N.D’AIUTO 10/16/14
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
-L-
INCLUDED IN THE PRICE BID FOR THE PRECAST UNITS.
THE COST OF THE PERMITTED THREADED INSERTS SHALL BE
CONTRACTOR IMMEDIATELY FOLLOWING REMOVAL OF THE FALSEWORK.
THE PERMITTED THREADED INSERTS SHALL BE GROUTED BY THE
MAY BE USED AS AN ALTERNATE.
STANDARD SPECIFICATIONS. STAINLESS STEEL THREADED INSERTS
AND GALVANIZED IN ACCORDANCE WITH SECTION 1076 OF THE
SHALL BE SIZED BY THE CONTRACTOR, SPACED AT 4’-0" CENTERS
THE PERMITTED THREADED INSERTS IN THE EXTERIOR UNITS
DURING CONSTRUCTION.
FOR THE CONTRACTOR TO ATTACH FALSEWORK AND FORMWORK
THE PERMITTED THREADED INSERTS ARE DETAILED AS AN OPTION
FOR GROUT FOR STRUCTURES, SEE SPECIAL PROVISIONS.
TRANSVERSE REINFORCING STEEL.
WHERE NECESSARY TO CLEAR PRESTRESSING STRANDS OR
THE LOCATION OF THE VOID DRAINS MAY BE SHIFTED SLIGHTLY
THOSE SEGMENTS LESS THAN 10 FEET IN LENGTH.
IN LENGTH AND NO CONTRACTION JOINTS ARE REQUIRED FOR
AT MIDPOINT OF BARRIER RAILSEGMENTS LESS THAN 20 FEET
EXPANSION JOINTS. ONLY ONE CONTRACTION JOINT IS REQUIRED
LOCATED AT EACH THIRD POINT BETWEEN BARRIER RAIL
SPECIFICATIONS. A VERTICAL CONTRACTION JOINT SHALL BE
IN ACCORDANCE WITH ARTICLE 825-10(B) OF THE STANDARD
BE TOOLED IN ALL EXPOSED FACES OF THE BARRIER RAIL AND
VERTICAL GROOVED CONTRACTION JOINTS, � " IN DEPTH, SHALL
APPLY EPOXY PROTECTIVE COATING TO BOX BEAM UNIT ENDS.
BEAM UNIT ENDS.
PRESTRESSING STRANDS SHALL BE CUT FLUSH WITH THE BOX
SHALL BE EPOXY COATED.
ALL REINFORCING STEEL IN VERTICAL CONCRETE BARRIER RAILS
A COMPRESSIVE STRENGTH OF NOT LESS THAN 6,000 PSI.
BEAM UNIT SHALL BE DONE WHEN THE CONCRETE HAS REACHED
THE TRANSFER OF LOAD FROM THE ANCHORAGES TO THE BOX
SPECIFICATIONS.
TYPE M BOND BREAKER. SEE SECTION 1028 OF THE STANDARD
THE BACKER RODS SHALL CONFORM TO THE REQUIREMENTS OF
SHALL BE FILLED WITH NON-SHRINK GROUT.
THE 2� " ~ DOWEL HOLES AT FIXED ENDS OF BOX BEAM SECTIONS
THE TENSIONING OF THE STRANDS.
RECESSES FOR TRANSVERSE STRANDS SHALL BE GROUTED AFTER
IS NOT ALLOWED.
FLAME CUTTING OF THE TRANSVERSE POST-TENSIONING STRAND
PRICE BID FOR PRESTRESSED CONCRETE BOX BEAMS.
SHALL BE GRADE 60 AND SHALL BE INCLUDED IN THE UNIT
ALL REINFORCING STEEL CAST WITH THE BOX BEAM SECTIONS
ACCORDANCE WITH THE STANDARD SPECIFICATIONS.
EXCEPT FOR SAMPLING REQUIREMENTS WHICH SHALL BE IN
GRADE 270 STRANDS AND SHALL CONFORM TO AASHTO M203
ALL PRESTRESSING STRANDS SHALL BE 7-WIRE LOW RELAXATION
S-4
9"
M.E.GILES 12/5/14
0" @ W.P.
LONG CHORD
5� " @ MID-SPAN
1/30/2015
![Page 6: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/6.jpg)
1’-4"
6"
2’-5"
85’-0" BOX BEAM UNIT LENGTH
GUTTERLINE
10 P
RE
ST
RE
SS
ED
CO
NC
RE
TE
BO
X B
EA
M U
NIT
S =
30’-0"
1’-0"
BA
RR
IE
R R
AIL
(T
YP
.)
VE
RT
ICA
L C
ON
CR
ET
E
1"
(T
YP
.)
27
’-1
0" (
CL
EA
R R
OA
DW
AY
)
FIX. FIX.
(TYP.)
120° -00’-00"
9" TO {BRG. (TYP.)
STRANDS (TYP.)
L. R. TRANSVERSE POST-TENSIONING
{ 2� " ~ HOLES FOR 0.6" ~
5�"
5�"
6"
BOX BEAM UNIT)
VOID (TYP. EA.
2’-2" X 1’-9� "11"
#5 S6
&
#5 S5
#5 S6
&
#5 S5
NO. BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
3
4 16
PLAN OF 85’ UNIT
27’-10" CLEAR ROADWAY
NO. BY:
12
120° SKEW
27-JAN-2015 08:51
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_BX_01.dgn
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
DRAWN BY : DGE 8/11
85’-0"
21’-11� "
23’-0"23’-0"23’-0"8’-0"
5’-2� "
8’-0"
BOX BEAM UNIT)
VOID (TYP. EA.
2’-2" X 1’-9� "
(TYP.)
TRANSVERSE POST-TENSIONING STRANDS
{ 2� " ~ HOLES FOR 0.6" ~ L. R.
(TYP.)
VOIDS
2’-5� " 2’-0"5’-2� "21’-11� " 21’-11� "
5�"(TYP.)
5�"(TYP.)
9� "
3� "
(TYP.)
(TYP.)11"(TYP.)
(TYP.)(TYP.)
(TYP.)
PLAN OF UNIT
DIAPHRAGM AND VOID LAYOUT
3’-5"
(TYP.)
SPLICE
BARRIER RAIL (2 BAR RUN) (TYP.)
12-#5 B9 IN VERTICAL CONCRETE
GUTTERLINE
VIEW FOR LOCATION) (TYP.)
(2’-2" SPLICE) (SEE BOX BEAM SECTION
6-#5 B3 IN BOX BEAM (2 BAR RUN)
BARRIER RAIL (2 BAR RUN) (TYP.)
12-#5 B9 IN VERTICAL CONCRETE
CONCRETE BARRIER RAIL)
7-#5 S6 @ 6" CTS. (TYP. EA. VERTICAL
CONCRETE BARRIER RAIL)
7-#5 S6 @ 6" CTS. (TYP. EA. VERTICAL
EA. EXTERIOR BOX BEAM UNIT)
CONCRETE BARRIER RAIL AND
7-#5 S5 @ 6" CTS. (TYP. EA. VERTICAL
100-#5 S5 @ 9" CTS. (TYP. EA. VERTICAL CONCRETE BARRIER RAIL AND EA. EXTERIOR BOX BEAM UNIT)
EA. EXTERIOR BOX BEAM UNIT)
CONCRETE BARRIER RAIL AND
7-#5 S5 @ 6" CTS. (TYP. EA. VERTICAL
100-#5 S6 @ 9" CTS. (TYP. EA. VERTICAL CONCRETE BARRIER RAIL)
8’-0" 23’-0" 23’-0" 23’-0" 8’-0"
CHECKED BY : TMG 11/11
STD.NO.33PCBB_30_120S_85L
2’-0"
REV. 8/14 MAA/TMG
28’-0" 28’-6" 28’-6"
(TYP.)
MAT’L. IN RAIL
{ � " EXP. JT.
17BP.10.R.71
13+26.00 -L-
UNION
SHEET 2 OF 5
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
10/16/14N.D’AIUTO
S-5M.E.GILES 12/5/14
(TYP.)
MAT’L. IN RAIL
{ � " EXP. JT.
LONG CHORD
1’-4" 2’-5"
@ END BENT 1
FILL FACE
@ END BENT 2
FILL FACE
1/27/2015
![Page 7: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/7.jpg)
3
"
4"
5-#4 A
2
7" 7"
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
427-JAN-2015 08:51
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_BX_01.dgn
END ELEVATION
STRAND LAYOUT NOT SHOWN.)
SECTION SIMILAR EXCEPT SHEAR KEY LOCATION.
(INTERIOR BOX BEAM SECTION SHOWN-EXTERIOR
AND LOCATION OF DOWEL HOLES.
SHOWING PLACEMENT OF #5 & #4 ‘‘A’’ BARS
INTERIOR BOX BEAM SECTION
(STRAND LAYOUT NOT SHOWN)
STRAND LAYOUT0.6" ~ LOW RELAXATION
STANDARD
2� " CL.
CHAMFER (TYP.)
3" X 3" 1’-9�"
2’-2"
3"
3"
5"
6
"
2’-9"
5�"
1
" C
L.
#4 S2
#4 S4
#4 S1
3’-0"
#4 S3
3�"
1’-0"1’-0"
1�"
CL
.C
L.
1�"
5"
2" CL.
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
5" 5"
SHEAR KEY DETAIL
NOTE: OMIT SHEAR KEY ON OUTSIDE FACEOF EXTERIOR BOX BEAMS.
8" 6" 6" 8"
4" 5-#5 A1 4"
@ E
QU
AL
SP
AC
ES
BAR TYPES
BAR NUMBER SIZE TYPE WEIGHT WEIGHTLENGTH
INTERIOR UNITEXTERIOR UNIT
LENGTH
S1
S2
S5*
REINFORCING STEEL LBS.
LBS.
CU. YDS.
No.
STR
3
3
#4
#4
#4
BILL OF MATERIAL FOR ONE BOX BEAM SECTION
A1
A2
S3
S4
#5 5
0.6" � L.R. STRANDS
#4
#4 4
3
#4
#4
#4
S11
S12
S13
2
10
#5
* EPOXY COATED REINF. STEEL
LBS.
CU. YDS.
No.
1 6’-8" 6’-8"
4’-10" 4’-10"
7’-6" 7’-6"
5’-8" 5’-8"
5’-10" 5’-10"
-- --
1’-6
"
2’-8"
1’-2"
TYP.
4TY
P.
3’-6"
10"
1 TOP OF UNIT
THIS LEG AT
2’-4
"
TY
P.
2’-8"
3
1’-6"
3"
3"
4"
1’-1
"
6"6"
#5
2’-5
"
70 70
7
7
7
S1
S2
S3
2’-5"
7
1’-6"
1’-1
"
2’-5
"S
11
S1
2
S1
3
4’-10" 4’-10"
3’-11" 3’-11"
3’-6" 3’-6"
K1
K2
6#4
#4
6’-2" 6’-2"
STR
6
4� " 4� "
2’-4"
9"
VOID
VOID
7"
#5 A1
6"
7"
#5 A1
6"
2’-0"
4’-3"
4’-3"
2’-0"
(SEE DETAIL ‘‘B’’)
(SEE DETAIL ‘‘B’’)
5-#4 A2
5-#4 A2
DOWEL HOLES
À 2� " �
DOWEL HOLES
À 2� " �
3’-0"
DOWEL HOLE
{ 2� " ~
9"9"
4"
4"
5-#5 A
1
(TY
P.
EA
. E
ND
)
49-#4 S4 @ 1’-6" CTS.
99-#4 S3 @ 9" CTS.
PLAN OF BOX BEAM
(T
YP
.)(T
YP
.)
11 SPACES @ 6" MAX. CTS.
@ 3" MIN. CTS.
@ 3" MIN. CTS.
11 SPACES @ 6" MAX. CTS.
#4 ‘‘S’’ BARS
#4 ‘‘S’’ BARS
2’-6"
1’-0"
1’-9
"
5
7"
3"
3"
6"
DETAIL ‘‘B’’
@ 6" MAX. CTS.
CHAMFER DETAIL
6"
CHAMFER
SHOWING 6" VOID CHAMFER
VOID
@ 3" MIN. CTS.
#4 ‘‘S’’ BARS
32
75
8432
32 75
84
EXTERIOR BOX BEAM SECTION
(STRAND LAYOUT NOT SHOWN)
1’-9�"
2’-2"
5"
6
"
2’-9"
5�"
1" C
L.
#4 S2
#4 S4
#4 S1
#4 S3
5"
2" CL.
CHAMFER (TYP.)
3" X 3"
3’-0"
3� "
CL.
#5 S5
1�"
CL
.
#4 S12
2" CL.
#4 S13
(TYP.)
#4 S11
END VIEW
4�"
1�"
CL
.
BOX BEAM UNIT
PRESTRESSED CONCRETE
3’-0" X 2’-9"
DRAWN BY : DGE 11/11
CHECKED BY : TMG 11/11 16
1’-4�"
85’-0"
11 SPACES
4’-3"
114-#5 S5 SEE ‘‘PLAN OF 1’-4"
UNIT’’ FOR SPACING
(SHOWING #4 ‘‘S’’ BARS IN END OF BEAM)
7� "7� "
1’-4"2’-5" 114-#5 S5 IN VERTICAL CONCRETE BARRIER RAIL AND EXTERIOR BOX BEAM UNIT
(SEE PLAN OF UNIT FOR DETAILS)
34 5’-11" 134 5’-11" 134
B3 12 543 543
12 49 49
8 2’-10" 15 2’-10" 15
62 311 311
62 235 235
111 358 358
49 191 191
114 5’-10" 694
694
15.2 15.1
30 30
#5 B3
#5 B3
#5 B3#5 B3
#5 B3
#5 B3
#5 B3#5 B3
#5 B3#5 B3
#5 B3#5 B3
5’-11� "
5’-11� "
43’-5"
TYPICAL STRAND LOCATION
DEBONDING LEGEND
30( STRANDS REQUIRED)
FULLY BONDED STRANDS
STRANDS DEBONDED FOR 4’-0" FROM END OF GIRDER
STRANDS DEBONDED FOR 12’-0" FROM END OF GIRDER
ARTICLE 1078-7.
BOX BEAM. SEE STANDARD SPECIFICATIONS
THE SPECIFIED LENGTH FROM EACH END OF THE
BOND SHALL BE BROKEN ON STRANDS AS SHOWN FOR
2’-2"
3"
2"
3"
9 SPA. @
1’-9
�"
2 SPA @
2" CTS.
2’-0
"
3"3"
2" CTS.
3"
0.217
58,600
0.6" � L.R.
GRADE 270 STRANDS
43,950
43’-5"
1’-6"
1’-6"
2
1’-5� "
2’-11"
1�" CL.
1�" CL.
3"
3"9"
3"
3"
9"
(TYP.)
120° -00’-00"
{ BOX BEAM
‘‘B’’ BARS AND ‘‘A’’ BARS NOT SHOWN.
SIMILAR EXCEPT OMIT #5 S5 BARS.
EXTERIOR UNIT SHOWN, INTERIOR UNIT
STD. NO. 33PCBB4_120S_85L
FOR REINFORCING STEEL IN DIAPHRAGMS, SEE ‘‘DOUBLE DIAPHRAGM DETAILS’’.
FOR THREADED INSERTS, SEE ‘‘THREADED INSERT DETAIL’’.
FOR LOCATION OF DIAPHRAGMS, SEE ‘‘PLAN OF UNIT’’.
EXTERIOR UNIT SHOWN, INTERIOR UNIT SIMILAR EXCEPT OMIT #5 S5 BARS.
REV. 8/14 MAA/TMG
(SQUARE INCHES)
AREA
(LBS. PER STRAND)
ULTIMATE STRENGTH
(LBS. PER STRAND)
APPLIED PRESTRESS
� "
�"
6"
6"
�"
� "
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
17BP.10.R.71
13+26.00 -L-
UNION
SHEET 3 OF 5
N.D’AIUTO 10/16/14
S-6
2" 4" 4" 2"
#4 S13 (IN PAIRS)
#4 S11, #4 S12 &
& #4 S3
#4 S1, #4 S2
DOWEL HOLES
{ OF 2� " ~
50-#4 S1 & #4 S2 @ 1’-6" CTS.
#4 S11, #4 S12 & #4 S13 (IN PAIRS) #4 S11, #4 S12 & #4 S13 (IN PAIRS)
#4 S4
#4 S3 &
#4 S4
#4 S3 &
#4 S1, #4 S2 & #4 S3 #4 S1, #4 S2 & #4 S3
12/5/14M.E.GILES
ALL BAR DIMENSIONS ARE OUT TO OUT.
103103
2,1682,168
8,000 P.S.I. CONCRETE
1/27/2015
![Page 8: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/8.jpg)
FINAL CAMBER
SUPERIMPOSED DEAD LOAD
DEFLECTION DUE TO
** INCLUDES FUTURE WEARING SURFACE
**
STRAND
0.6" � L.R.
PART SECTION AT RECESS
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
427-JAN-2015 08:51
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_BX_01.dgn
STANDARD
BOX BEAM UNIT
PRESTRESSED CONCRETE
3’-0" X 2’-9"
5� "
DETAIL ‘‘C’’
SEE DETAIL ‘‘C’’
8
"1’-0"
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
NON-SHRINK GROUT
FILL RECESS WITH
SECTION A-A
1’-0"
9"
10
"7
"
8"
#4 A2
2� "
CL.
1’-1"
1’-1"
7"
8"
2�"
CL
.
#4 K2
{ DIAPHRAGM
2�"
CL
.
1’-0
"
SIDE)
(EACH
#4 A2
9"
7
"
7"
10
"
1’-1"
#4 K1
SECTION D-D
(TYP.)
1" CL.
5� "5� "
11"
VOIDS NOT SHOWN
2-#4 K2
5"
5"
1’-1
�" X
5
�"
(TYP.)
STRAND VISE
1’-2
" X
6"
(TYP.)
5" X 5" X � " }
1" MIN. CL.
(TYP.)
5� "
SHOWING PLAN VIEW OF GROUTED RECESS
8
"
1’-0"
1’-1"
VIEW Y-Y
SHOWING ELEVATION VIEW OF GROUTED RECESS
5� "
6"
1’-1�"
1’-2"
STRAND (TYP.)
POST-TENSIONING
FOR 0.6" ~
2� " ~ HOLE
(DIMENSIONS SHOWN ARE TYPICAL FOR EACH VOID)
SECTION B-B
VOID DRAIN DETAILS
10" 10"
DRAIN
{ VOID
X X
OF EXTERIOR BOX BEAM
END OF POST-TENSIONED STRANDS
GROUTED RECESS DETAIL AT
DOUBLE DIAPHRAGM DETAILS
2� " ~ HOLE)
#4 K1 (CENTER ABOUT STRAND
POST-TENSIONING
2� " ~ HOLE FOR 0.6" ~
PART PLAN
10
"1
0"
(T
YP
.)(T
YP
.)
DIAPHRAGM
VOID
B
B
DRAIN
{ 1" ~ VOID DRAIN
{ 1" ~ VOID
VOID
VOID DRAIN
{ 1" ~
6"6"6"6"
(TYP.)
DRAIN
VOID
PLAN
A
A
3-#4 A2
#4 K2
#4 K2
3-#4 A2
D
D
11"5�"5�
"
8"
3-#
4 K
18
"
10
"1
0"
NON-SHRINK GROUT
FILL RECESS WITH
5�"
�"
�"
EXTERIOR BOX BEAM
OUTSIDE FACE OF
Y
Y
VISE
STRAND
5" X 5" X � " }
SECTION X-X
STRAND
POST-TENSIONING
{ 0.6" ~ L.R. TRANSVERSE
1"
6"
5�"
DRAWN BY : DGE 11/11
CHECKED BY : TMG 11/11 16
(TYP.) (TYP.)
3� " 9� "
STRAND (TYP.)
POST-TENSIONING
0.6" ~ L.R. TRANSVERSE
STD.NO.33PCBB5_120S
STRANDS
POST-TENSIONING
{ 2� " ~ HOLES FOR
3’-0" x 2’-9"
#4 ‘‘S’’ BARS NOT SHOWN. #4 ‘‘S’’ BARS MAY BE SHIFTED SLIGHTLY TO CLEAR 2� " ~ HOLE.
STRAND
POST-TENSIONING
0.6" ~ L.R. TRANSVERSE
{ 2� " ~ HOLE FOR
2� "
� "
2"
REV. 8/14 MAA/TMG
CAMBER (SLAB ALONE IN PLACE)
17BP.10.R.71
UNION
13+26.00 -L-
SHEET 4 OF 5
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
N.D’AIUTO 10/16/14
DEAD LOAD DEFLECTION AND CAMBER
S-712/5/14M.E.GILES
85’ BOX BEAM UNIT
1/27/2015
![Page 9: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/9.jpg)
À BEARING PAD
4� "
3�"
4� "2’-9"
9"
3�"
1"
EXTERIOR B.B.
TOTAL
LENGTH LENGTH
TOTAL
2 85’-0" 170’-0"
8 85’-0" 680’-0"
10 850’-0"
BAR SIZE TYPE LENGTH WEIGHT
CLASS AA CONCRETE
LBS.
CU.YDS.
* EPOXY COATED REINFORCING STEEL
* #5
* #5 STR
LN. FT.
BARS PER PAIR OF EXTERIOR UNITS
BOX BEAM UNITS REQUIRED
85’ UNITS
@ MID-SPAN
ASPHALT OVERLAY THICKNESS
@ MID-SPAN
RAIL HEIGHT
1� "
GUTTERLINE ASPHALT THICKNESS & RAIL HEIGHT
2’-1�"
INTERIOR B.B.
NUMBER
STD. NO. 33PCBB8_60&120S
TOTAL VERTICAL CONCRETE BARRIER RAIL
85’ UNIT
228 7’-2"S6
B9
1
144
- TYPE II -
BEARING PAD
22.0
3’-7� "
17BP.10.R.71
UNION
13+26.00 -L-
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTAL
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
4
SHEET 5 OF 5
27-JAN-2015 08:51
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_BX_01.dgn
FIXED END
ELASTOMERIC BEARING DETAILSELASTOMER IN ALL BEARINGS SHALL BE 60 DUROMETER HARDNESS.
BAR TYPE
BAR DIMENSIONS ARE OUT TO OUT
3’-4"
6"
7� "
SECTION THRU RAIL
DRAWN BY : DGE 10/11
CHECKED BY : TMG 11/11
BOX BEAM UNIT
PRESTRESSED CONCRETE
3’-0" X 2’-9"
16
VERTICAL CONCRETE BARRIER RAIL DETAILS
1
10"
1’-0"
1" 1"
CONST. JT.
2’-0"
7"
7"
6"
SIDE VIEWEND VIEW
‘‘B’’ BARS
FIELD BEND
#5 S5
(TYP.)
#5 S5
#5 S6
FIELD CUT
#5 S6
#5 S6
CUT
FIELD
END OF RAIL DETAILS
CHAMFER
CHAMFER
� "
� "
CONST. JT.
S
S
WHEN SLIP FORM IS USED)
(NOTE: OMIT EXP. JT. MAT’L.
PLACE WITH GALVANIZED NAILS.
À � " EXP. JT. MAT’L HELD IN
ELEVATION AT EXPANSION JOINTS SECTION S-S6"
2� "
2"
2� "
2� "
WHEN SLIP FORM IS USED)
(THIS IS TO BE USED ONLY
AT DAM IN OPEN JOINT
#5 ‘
‘B’’
BA
RS
MAA/TMGREV. 8/14
(TYPE II - 20 REQ’D)
À 1� " � HOLES
@ 6" CTS.
& #5 S6
#5 S5 & #5 S6
4,107
S-8
DATE :
DATE :
N.D’AIUTO 10/16/14
12/5/14M.E.GILESASSEMBLED BY :
CHECKED BY :
SHEETS
BILL OF MATERIAL FOR VERTICAL CONCRETE BARRIER RAIL
STANDARD
16’-0" 2,403
1,704
170.00
2" CL.
3� "
3’-9
�"
@ {
BR
G.
@ M
ID-S
PA
N
RA
IL H
EIG
HT
’’ T
AB
LE
)
AS
PH
AL
T T
HIC
KN
ES
S &
VA
RIE
S (
SE
E ‘
‘GU
TT
ER
LIN
E
1’-4�"
3’-6
"
SL
OP
ED
FA
CE
2"
(TYP.)
VA
RIE
S
FA
CE
VE
RT
ICA
L
1’-0"
10" 1"1"
#5 S5
#5 S610
"7
�"
9"
6"
6"
3"
12
-#
5 B
9 B
AR
S
1"
@ 9" CTS.
7-#5 S5
1/27/2015
![Page 10: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/10.jpg)
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
427-JAN-2015 08:51
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_GR_01.dgn
STANDARD
STD. NO. GRA3
E
E
FOR LOCATION OF GUARDRAIL ANCHOR
ANCHOR ASSEMBLY
À GUARDRAIL
* DENOTES GUARDRAIL ANCHOR ASSEMBLY
END BENT
{ JT. @
GUARDRAIL ANCHOR ASSEMBLY DETAILS
PLAN
SECTION E-E
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
CHECKED BY : GM 5/10
FINISH GRADE
ASSEMBLY, SEE ‘‘PLAN’’ BELOW
À GUARDRAIL
ANCHOR ASSEMBLY
1’-6
"
À 1� " ~ HOLES (TYP.)
� " HOLD-DOWN }
3�"
3�"
3�"
3�"
11"
4" 4"
BARRIER RAIL
FOR VERTICAL CONCRETE
GUARDRAIL ANCHORAGE
DRAWN BY : MAA 5/10
ELEVATION
PLAN
ANCHOR ASSEMBLY
À GUARDRAIL
REV. 10/1/11 MAA/GM
POINTS OF ATTACHMENT
SKETCH SHOWING
ANCHORS FOR GUARDRAIL
LOCATION OF
REV. 12/5/11 MAA/GM
ASSEMBLY
ANCHOR
À GUARDRAIL
� " HOLD-DOWN }
WASHERS (TYP.)
WITH ROUND
{ � " ~ X 1’-2" BOLT
3�"
3�"
3�"
3�"
1’-
11"
(TYP.)
1� " ~ HOLE
REV. 6/13 MAA/GM
END BENT
À JT. @
4"
4"
4"
4"
1’-10"
ANCHOR ASSEMBLY
{ GUARDRAIL
1’-10"
ANCHOR ASSEMBLY
{ GUARDRAIL
NOTES
END BENT 1 SHOWN, END BENT 2 SIMILAR.
*
* *
*
END BENT 1
{ JT. @
END BENT 2
{ JT. @
17BP.10.R.71
13+26.00 -L-
UNION
N.D’AIUTO 10/16/14
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
12/5/14M.E.GILES
TO THE SATISFACTION OF THE ENGINEER.
WILL NOT BE PERMITTED. ANY CONCRETE DAMAGED BY THIS WORK SHALL BE REPAIRED
THE 1� " ~ HOLES SHALL BE FORMED OR DRILLED WITH A CORE BIT. IMPACT TOOLS
CONCRETE BARRIER RAIL TO CLEAR ASSEMBLY BOLTS.
THE VERTICAL REINFORCING BARS MAY BE SHIFTED SLIGHTLY IN THE VERTICAL
CONTRACT PRICE BID FOR VERTICAL CONCRETE BARRIER RAIL.
THE COST OF THE GUARDRAIL ANCHOR ASSEMBLY SHALL BE INCLUDED IN THE UNIT
SHARP POINTED TOOL.
AFTER INSTALLATION, THE EXPOSED THREAD OF THE BOLT SHALL BE BURRED WITH A
ATTACHMENT, SEE SKETCH.
GUARDRAIL IS TO BE ATTACHED TO THE END OF BARRIER RAIL. FOR POINTS OF
THE GUARDRAIL ANCHOR ASSEMBLY IS REQUIRED AT ALL POINTS WHERE APPROACH
THE ENGINEER.)
REQUIREMENTS OF ASTM A307. THE USE OF THIS ALTERNATE SHALL BE APPROVED BY
NUTS AND WASHERS. THEY SHALL CONFORM TO OR EXCEED THE MECHANICAL
AND WASHERS MAY BE USED AS AN ALTERNATE FOR THE � ’’ ~ GALVANIZED BOLTS,
BE GALVANIZED. (AT THE CONTRACTOR’S OPTION, STAINLESS STEEL BOLTS, NUTS
CONFORM TO THE REQUIREMENTS OF AASHTO M291. BOLTS, NUTS AND WASHERS SHALL
BOLTS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A307 AND NUTS SHALL
WITH AASHTO M111.
FABRICATION, THE HOLD-DOWN PLATE SHALL BE HOT-DIP GALVANIZED IN ACCORDANCE
THE HOLD-DOWN PLATE SHALL CONFORM TO AASHTO M270 GRADE 36. AFTER
7-� " ~ BOLTS WITH NUTS AND WASHERS.
THE GUARDRAIL ANCHOR ASSEMBLY SHALL CONSIST OF A � " HOLD DOWN PLATE AND
S-9
16
1’-
11
"
4"
4"
1/27/2015
![Page 11: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/11.jpg)
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
419-JAN-2016 10:31
ndaiuto
S:\DPG2\oldDPG3\DivisionLets\Div10\Submitted\17BP.10.R.71\Plans\17BP10R71_SD_E1_01.dgn
SUBSTRUCTURE
16
ELEVATION
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
W1
1’-9"
5�"
5�"
CH
AM
FE
R
CH
AM
FE
R
W2
42’-2"
17’-1� " 17’-2� "
9’-6"
1 2 4
8’-9"9’-6"
3 5
9’-6"
(TYP.)
9"
(TYP.)
9"
SHEET 1 OF 3@ 8" CTS. (TYP. EACH BAY)
22’-8" 19’-6"
2’-9� "
SEE ‘‘CORROSION PROTECTION FOR STEEL PILES DETAIL’’, SHEET 4 OF 4.
CONCRETE COLLARS FOR STEEL PILES NOT SHOWN IN PLAN AND ELEVATION VIEWS FOR CLARITY.
FOR SECTION A-A, SEE SHEET 4 OF 4.
WINGS NOT SHOWN FOR CLARITY.
1
2
3
4
5
ELEVATIONS
TOP OF PILE
2’-0�"
1’-3
"
(TYP.
)FILL FACE
9’-6
�"
11’-0"
13’-0�"
6’-6� "
1’-9"
2’-9"
11’-0"
(TYP.
)1’-0
"
4’-0
"
(M
IN
.)
BOTTOM OF CAP
& WING
POUR #1
CAP, LOWER
PART OF WINGS &
CONCRETE COLLARS
(TYP. EA. END)
(TYP.)
9"
(T
YP
.)
1’-0"
2’-0" MIN.
4-#4 S3
(TYP. EA. PILE)
A
A
NOTES
FOR WING DETAILS, SEE SHEET 2 OF 3.
FOR PILE SPLICE DETAILS, SEE SHEET 3 OF 3.
CAST IF SLIP FORMING IS USED.
VERTICAL CONCRETE BARRIER RAIL IS
THE WING SHALL BE POURED AFTER THE
THE CONCRETE IN THE SHADED AREA OF
NECESSARY TO CLEAR DOWELS.
STIRRUPS IN CAP MAY BE SHIFTED AS
11’-3�"
SEE DETAIL ‘‘A’’
(SHEET 3 OF 3)
MAT’L. (TYP.)
1" EXP. JT.
1’-0
"
1’-4
�"
TO
{ P
IL
ES
BA
CK
WA
LL
(TYP.)
2’-1� " 1’-4� "
(TYP.)
1’-8� "
#4 K1 (TYP.)
(LEVEL)
TOP OF WING
(11 REQ’D)
OVER PILES @ 4’-0" CTS.
#4 B3 UNDER #4 B2
(2’-5" MIN. SPLICE)
(2 BAR RUN)
(OVER PILES)
4-#4 B2
4-#9 B1
3" HIGH BEAM BOLSTER
@ 5’-0" CTS.
CONST. JT.
(TYP.)
TOP OF WING
(LEVEL)
PLAN
WORKLINE
35-#4 V2 @ 1’-0" CTS. (EA. FACE)
35-#4 U1 @ 1’-0" CTS.
1’-1
0�"
TO
(TYP.)
EMBEDMENT
& BACKWALL
OF WINGS
UPPER PART
POUR #2
EL. 519.37
EL. 526.87
EL. 523.37
EL. 524.16EL. 524.79
& WING
BOTTOM OF CAP
EL. 517.74
EL. 521.74
EL. 525.24
EL. 523.52
521.29
520.94
520.58
520.23
519.87
END BENT 1
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
17.BP.10.R.71
UNION
13+26.00 -L-
N.D’AIUTO 10/21/14
DATE :DESIGN ENGINEER OF RECORD: N.D’AIUTO 1/21/15
(2’-5" MIN. SPLICE)
(2 BAR RUN)
#4 K2 (EA. FACE)
S-10
W.P. #1
#4 S1 & #4 S213-#4 S1 & #4 S2
(2’-5" MIN. SPLICE)
(2 BAR RUN)
#4 B2 (EA. FACE)
M.E.GILES 12/8/14
{ HP 12X53 STEEL PILES
EL. 522.53
EL. 518.53
LONG CHORD
6’-11� "
4� "
(TO LONG CHORD)
120° -00’-00"
& D
OW
EL
S
TO
{ B
RG
.
9"
-3.727%
2� "
-3.727%
2’-10� "
SIGNATURES COMPLETED
FINAL UNLESS ALL
DOCUMENT NOT CONSIDERED
13’-0�"
2’-0�"
9’-3
�"
11’-0�"
1/20/2016
![Page 12: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/12.jpg)
SECTION X-X
#4 V1
CONST. JT.
3"
3" HIGH B.B.
FILL FACE
1’-0"
2" CL.2" CL.
12
-#
5 H
3 (
EA
CH
FA
CE
)
2 S
PA
. @
8" C
TS
.
5 S
PA
. @
8" C
TS
.
2 S
PA
. @
8" C
TS
.
#4 V1
CONST. JT.
3"
3" HIGH B.B.
1’-0"
2" CL.2" CL.
12-#5 H
1 (
FIL
L F
AC
E)
2 S
PA
. @
8" C
TS
.
5 S
PA
. @
8" C
TS
.
2 S
PA
. @
8" C
TS
.
SECTION Y-Y
FACE
FILL
3"
PO
UR
#1
PO
UR
#2
TOP OF WING
CONST. JT.
#4 V1 BARS (EA. FACE)
(SPACED AS SHOWN ABOVE)
(LEVEL)
12
-#
5 H
1 (
FIL
L F
AC
E)
3"
3" HIGH B.B.
@ 5’-0" CTS.
BOTTOM OF WING
(LEVEL)
2 S
PA
. @
8" C
TS
.
5 S
PA
. @
8" C
TS
.
#4 K1 (EA. FACE)
2 S
PA
. @
8" C
TS
.
PO
UR
#1
PO
UR
#2
12
-#
5 H
3 (
EA
CH
FA
CE
)
3"
BOTTOM OF WING
(LEVEL)
3"
TOP OF WING
(LEVEL)
#4 V1 BARS (EA. FACE)
(SPACED AS SHOWN ABOVE)
#4 K1 (EA. FACE)
5 S
PA
. @
8" C
TS
.
WING DETAILS
X
X
2 S
PA
. @
8" C
TS
.
2 S
PA
. @
8" C
TS
.
3" HIGH B.B.
@ 5’-0" CTS.
CONST. JT.
Y
Y
SUBSTRUCTURE
16
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
4
SHEET 2 OF 3
19-JAN-2016 10:31
ndaiuto
S:\DPG2\oldDPG3\DivisionLets\Div10\Submitted\17BP.10.R.71\Plans\17BP10R71_SD_E1_01.dgn
PLAN OF WING W1
#5 H3
2’-0� " 11’-0"
13’-0� "
10-#4 V1 @ 1’-0" CTS. (EA. FACE)
1’-0"
2" C
L.
2" C
L.
3"
11’-0" 2’-0� "
3"
#5 H1
13’-0� "
1’-0"
2" C
L.
2" C
L.
12-#5 H
2 (
BA
CK
FA
CE
)
12-#5 H
2 (
BA
CK
FA
CE
)
10-#4 V1 @ 1’-0" CTS. (EA. FACE)
JT. MAT’L.
1" EXP.
#4 K1
FILL FACE
2" CL.(TYP.)
(T
YP
.)
1’-0"
1’-9"
2’-9"
2 SPA.
@
2 SPA.
@
10-#4 V1
10-#4 V1
8"
#4 V1
(SPA. AS SHO
WN)
(EA. FACE)
1’-0" CTS.
2" CL.
#5 H2
2’-9�
"
2" CL.
5�"
CHAMFER
CHAMFER
5�"
(SPA. AS SHO
WN)
(EA. FACE)
1’-0" CTS.
2" CL.
1’-0"
1’-9"
2’-9"
(TYP.)
(T
YP
.)
2"
2"
#4 K1
FACE
FILL
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY : N.D’AIUTO 10/21/14
ELEVATION OF WING W2
17.BP.10.R.71
UNION
13+26.00 -L-
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
ELEVATION OF WING W1
PLAN OF WING W2
S-11
M.E.GILES 12/8/14
WING DETAILS
END BENT 1
DESIGN ENGINEER OF RECORD: N.D’AIUTO DATE : 1/21/15
3’-11�"
SIGNATURES COMPLETED
FINAL UNLESS ALL
DOCUMENT NOT CONSIDERED
MAT’L
1" EXP. JT.
3’-11�
"
2’-10�"
1/20/2016
![Page 13: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/13.jpg)
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
427-JAN-2015 08:51
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_E1_01.dgn
SUBSTRUCTURE
(TYP. EACH PILE)
PLAN
COLLAR
CONCRETE
BOTTOM OF CAP
ELEVATION
CONCRETE COLLARS
{ PILES &
1’-4
�" 1’-6
"
2’-0"
FILL FACE
2’-0" ~ CONCRETE COLLAR
BAGGED STONE SHALL REMAIN IN PLACE UNTIL THE ENGINEER DIRECTS THAT
ACCUMULATIONS AT BAGGED STONE WHEN SO DIRECTED BY THE ENGINEER.
BAGS SHALL BE REMOVED AND REPLACED WHENEVER THE ENGINEER DETER-
MINES THAT THEY HAVE DETERIORATED AND LOST THEIR EFFECTIVENESS.
NO SEPARATE PAYMENT WILL BE MADE FOR THIS WORK AND THE ENTIRE
COST OF THIS WORK SHALL BE INCLUDED IN THE UNIT CONTRACT PRICE
BID FOR THE SEVERAL PAY ITEMS.
BAGGED STONE AND PIPE SHALL BE PLACED IMMEDIATELY AFTER COMPLETION
PIPE WILL NOT BE ALLOWED.
STEEL, CORRUGATED ALUMINUM ALLOY, OR CORRUGATED PLASTIC. PERFORATED
OF END BENT EXCAVATION. PIPE MAY BE EITHER CONCRETE, CORRUGATED
IT BE REMOVED. THE CONTRACTOR SHALL REMOVE AND DISPOSE OF SILT
CORROSION PROTECTION FOR STEEL PILES DETAIL
ALL BAR DIMENSIONS ARE OUT TO OUT.
16
SHEET 3 OF 3
SEE ‘‘CORROSION PROTECTION FOR STEEL PILES DETAIL.’’)
(CONCRETE COLLAR NOT SHOWN FOR CLARITY.
DETAILS
45
60
45
60
POSITION OF PILE DURING WELDING.
DETAIL B
+10°
-0°
10°0°
BACK GOUGE
BACK GOUGEDETAIL A
DETAIL B
DETAIL A
PILE VERTICAL
OR VERTICAL
PILE HORIZONTAL
2’-9"
4’-0"
2’-3
"
2’-0
"
#4 S2
#4 S1
1’-2"
11"
#4 B3
3" HIGH B.B.
8"2" CL. (TYP.) 8"
8"
#4 S3
OVER PILES
4-#4 B2 @ 4" CTS.
1’-4� " 1’-4� "
{ #8 D1 DOWEL
4 S
PA
. @
7"
1’-10� "
1’-3"
CONST. JT.
#4 U1
#4 V2
2" CL.
11"
FILL FACE
1’-0"
1HK. HK.
HK
.
HK. HK.
1’-3" 1’-3"
4� " 4� "
4�"
1’-8" ~
2’-5"
2’-5"
2
11’-1"
41’-8"
10’-8"
H1
H2
10’-2"
3
5
4
6
5"
3’-7
�"
8"
7
{ BEARING
FILL FACE2’-1� "
(TYP.)
1’-3" ABOVE CAP
TO PROJECT
#8 D1 DOWELS1’-4� " 1’-4� "
2’-9"
4�"
4�"
9"
1’-10�"
PAD (TYPE II) (TYP.)
ELASTOMERIC BRG.
2’-9" X 9" X 1"1’-0� "1’-0� "
{ BOX BEAM
MINIMUM OF 3- ONE CUBIC
FOOT BAGS OF #78M STONE.
BAGS SHALL BE OF POROUS
FOR DRAINAGE
GRADE TO DRAIN
TOE OF SLOPE
6" ( MIN.) PIPEFABRIC,SECURELY TIED.
5"
6"
6"
6"
7�"
7�"
1’-7�"
1’-5
�"
17.BP.10.R.71
UNION
13+26.00 -L-
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
BAR TYPES
1’-3" LAP
TEMPORARY DRAINAGE AT END BENT PILE SPLICE DETAILS
DETAIL ‘‘A’’
SECTION A-A
0"
TO
�"
0" TO � "
0"
TO
�"
0" TO � "
S-12
STEEL PILE
{ HP 12X53
STEEL PILE
{ HP 12X53
POUR #1
POUR #2
TOTAL CLASS A CONCRETE
BAR
B1
NO.
8
SIZE
#9
TYPE
1
LENGTH
44’-2"
WEIGHT
1201
B2 28 #4 STR 415
B3 11 #4 STR 2’-5" 18
D1 20 #8 STR 2’-3"
H1 12 #5 2
K1 12 #4 STR 3’-3" 26
S1 54 #4 5
10’-5" 376S2 54 #4 4
3’-2"
S3 20 #4 6 6’-6" 87
V1 61 #4 STR 7’-2" 292
149
V2 70 #4 STR 5’-3"
35 84U1 #4 3’-7"7
120
K2 12 #4 STR 178
PART OF WINGS
BACKWALL & UPPER
H2 12 #5 2 11’-6" 144
H3 24 #5 3 275
114
21.0
5.7
26.7
LBS.
C.Y.
C.Y.
C.Y.
BILL OF MATERIAL
3,724
HP 12X53 STEEL PILES
LIN. FT.= 75NO: 5
PILE EXCAVATION IN SOIL
PILE EXCAVATION NOT IN SOIL
CLASS A CONCRETE BREAKDOWN
22’-2"
22’-2"
4-#9 B1
2-#9 B1
2-#9 B1
END BENT 1
5� "
CHECKED BY :
DATE :
DATE :
DATE :
ASSEMBLED BY : N.D’AIUTO 10/21/14
M.E.GILES 12/8/14
DESIGN ENGINEER OF RECORD: N.D’AIUTO 1/21/15
10"
10"
END BENT 1
11’-11"
11’-0"
245
REINFORCING STEEL
LIN. FT.= 39.00
LIN. FT.= 6.00
WINGS & COLLARS
CAP, LOWER PART OF
(EA. FACE)
#4 K2
(EA. FACE)
#4 B2
1/27/2015
![Page 14: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/14.jpg)
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
419-JAN-2016 10:31
ndaiuto
S:\DPG2\oldDPG3\DivisionLets\Div10\Submitted\17BP.10.R.71\Plans\17BP10R71_SD_E2_01.dgn
SUBSTRUCTURE
16
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
DRAWN BY : WJH 12/11
CHECKED BY : AAC 12/11
W1
1’-9"
5�"
5�"
CH
AM
FE
R
CH
AM
FE
R
W2
41’-8"
(TYP.
)1’-3
"
9’-6" 9’-6" 9’-6"
ELEVATION
1 3 5
SHEET 1 OF 3
8’-8� "
9� "
22’-5"19’-3"
(TYP.)
9"
@ 8" CTS. (TYP. EACH BAY)(TYP.)
9"
2 4
SEE ‘‘CORROSION PROTECTION FOR STEEL PILES DETAIL’’, SHEET 4 OF 4.
CONCRETE COLLARS FOR STEEL PILES NOT SHOWN IN PLAN AND ELEVATION VIEWS FOR CLARITY.
FOR SECTION A-A, SEE SHEET 4 OF 4.
WINGS NOT SHOWN FOR CLARITY.
2’-0�"
1’-9"
11’-0"
2’-9"
13’-0�"
9’-6
�"
2’-0�"
6’-6� "
(TYP.
)1’-0
"
-L-
FILL FACE
NOTES
FOR WING DETAILS, SEE SHEET 2 OF 3.
FOR PILE SPLICE DETAILS, SEE SHEET 3 OF 3.
CAST IF SLIP FORMING IS USED.
VERTICAL CONCRETE BARRIER RAIL IS
THE WING SHALL BE POURED AFTER THE
THE CONCRETE IN THE SHADED AREA OF
NECESSARY TO CLEAR DOWELS.
STIRRUPS IN CAP MAY BE SHIFTED AS
6’-6� "
9’-6
�"
11’-3�"
11’-0"
13’-0�"
(TYP. EA. END)
#4 S1 & #4 S2
(TYP.)
9"
(M
IN
.)
4’-0"
A
A
(TYP. EA. PILE)
4-#4 S3
(TYP.)
EMBEDMENT
2’-0" MIN.
(T
YP
.)
1’-0"
CONCRETE COLLARS
PART OF WINGS &
CAP, LOWER
POUR #1
4� "1’-8� "
1’-1
0�"
& D
OW
EL
S
TO
{ B
RG
.
{ P
IL
ES
1’-4
�"
TO
BA
CK
WA
LL
1’-0
"
2’-1� "
(TYP.)
1’-4� "
(TYP.)
11’-3�"
(LEVEL)
TOP OF WING
CONST. JT.
(TYP.)
3" HIGH BEAM BOLSTER
@ 5’-0" CTS.
4-#9 B1
(2’-5" MIN. SPLICE)
(2 BAR RUN)
(OVER PILES)
4-#4 B2
WORKLINE
(11 REQ’D)
OVER PILES @ 4’-0" CTS.
#4 B3 UNDER #4 B2
#4 K1 (TYP.)
MAT’L. (TYP.)
1" EXP. JT.
SEE DETAIL ‘‘A’’
(SHEET 3 OF 3)
STD. NO. EB_30_120S4_33BB
34-#4 V2 @ 1’-0" CTS. (EA. FACE)
34-#4 U1 @ 1’-0" CTS.
& BACKWALL
OF WINGS
UPPER PART
POUR #2
17.BP.10.R.71
UNION
13+26.00 -L-
END BENT 2
521.81
521.45
521.10
520.75
520.39
N.D’AIUTO 10/21/14
& WING
BOTTOM OF CAP
EL. 518.28
(LEVEL)
TOP OF WING
EL. 525.78
EL. 522.28
& WING
BOTTOM OF CAP
EL. 519.89
EL. 523.89
EL. 527.39
EL. 524.74
EL. 525.36
EL. 524.11
W.P. #2
PLAN
ELEVATION
S-13M.E.GILES 12/8/14
(2’-5" MIN. SPLICE)
(2 BAR RUN)
#4 B2 (EA. FACE)
(2’-5" MIN. SPLICE)
(2 BAR RUN)
#4 K2 (EA. FACE)
13-#4 S1 & #4 S2
ELEVATIONS
TOP OF PILE
1
2
3
4
5
{ HP 12X53 STEEL PILES
EL. 523.11
EL. 519.11
(TO LONG CHORD)
120° -00’-00"
CHORD
LONG
3"
-3.727%
-3.727%
16’-8� "16’-8� "
REV. 4/15 MAA/TMG
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
SIGNATURES COMPLETED
FINAL UNLESS ALL
DOCUMENT NOT CONSIDERED
2’-11� "2’-11� "
1/20/2016
![Page 15: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/15.jpg)
#5 H3
2’-0� " 11’-0"
13’-0� "
10-#4 V1 @ 1’-0" CTS. (EA. FACE)
1’-0
"
2" C
L.
2" C
L.
3"
11’-0" 2’-0� "
3"
#5 H1
13’-0� "
1’-0"
2" C
L.
2" C
L.
10-#4 V1 @ 1’-0" CTS. (EA. FACE)
JT. MAT’L.
1" EXP.
#4 K1
FILL FACE
2" CL.(TYP.)
(T
YP
.)
1’-0"
1’-9"
2’-9"
2 SPA.
@
2 SPA.
@
10-#4 V1
10-#4 V1
8"
#4 V1
(SPA. AS SHO
WN)
(EA. FACE)
1’-0" CTS.
2" CL.
#5 H2
2" CL.
5�"
CHAMFER
CHAMFER
5�"
(SPA. AS SHO
WN)
(EA. FACE)
1’-0" CTS.
2" CL.
1’-0"
1’-9"
2’-9"
(TYP.)
(T
YP
.)
2"
2"
#4 K1
FACE
FILL
MAT’L
1" EXP. JT.
SECTION X-X
#4 V1
CONST. JT.
3"
3" HIGH B.B.
FILL FACE
1’-0"
2" CL.2" CL.
12
-#
5 H
3 (
EA
CH
FA
CE
)
2 S
PA
. @
8" C
TS
.
5 S
PA
. @
8" C
TS
.
2 S
PA
. @
8" C
TS
.
#4 V1
CONST. JT.
3"
3" HIGH B.B.
1’-0"
2" CL.2" CL.
12-#5 H
1 (
FIL
L F
AC
E)
2 S
PA
. @
8" C
TS
.
5 S
PA
. @
8" C
TS
.
2 S
PA
. @
8" C
TS
.
SECTION Y-Y
FACE
FILL
3"
PO
UR
#1
PO
UR
#2
TOP OF WING
CONST. JT.
#4 V1 BARS (EA. FACE)
(SPACED AS SHOWN ABOVE)
(LEVEL)
12
-#
5 H
1 (
FIL
L F
AC
E)
3"
3" HIGH B.B.
@ 5’-0" CTS.
BOTTOM OF WING
(LEVEL)
2 S
PA
. @
8" C
TS
.
5 S
PA
. @
8" C
TS
.
#4 K1 (EA. FACE)
2 S
PA
. @
8" C
TS
.
PO
UR
#1
PO
UR
#2
12
-#
5 H
3 (
EA
CH
FA
CE
)
3"
BOTTOM OF WING
(LEVEL)
3"
TOP OF WING
(LEVEL)
#4 V1 BARS (EA. FACE)
(SPACED AS SHOWN ABOVE)
#4 K1 (EA. FACE)
5 S
PA
. @
8" C
TS
.
WING DETAILS
X
X
2 S
PA
. @
8" C
TS
.
2 S
PA
. @
8" C
TS
.
3" HIGH B.B.
@ 5’-0" CTS.
CONST. JT.
Y
Y
SUBSTRUCTURE
16
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
4
SHEET 2 OF 3
19-JAN-2016 10:31
ndaiuto
S:\DPG2\oldDPG3\DivisionLets\Div10\Submitted\17BP.10.R.71\Plans\17BP10R71_SD_E2_01.dgn
PLAN OF WING W1
12-#5 H
2 (
BA
CK
FA
CE
)
12-#5 H
2 (
BA
CK
FA
CE
)
STD. NO. EB_30_120S4_33BB
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
CHECKED BY : AAC 12/11
DRAWN BY : WJH 12/11
N.D’AIUTO 10/21/14
ELEVATION OF WING W2
17.BP.10.R.71
UNION
13+26.00 -L-
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
VELEVATION OF WING W1
PLAN OF WING W2
S-14M.E.GILES 12/8/14
WING DETAILS
END BENT 2
SIGNATURES COMPLETED
FINAL UNLESS ALL
DOCUMENT NOT CONSIDEREDREV. 4/15 MAA/TMG
2’-11�"
4’-1"
4’-1�"
2’-11�"
1/20/2016
![Page 16: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/16.jpg)
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
PROJECT NO.
DEPARTMENT OF TRANSPORTATION
12
3
427-JAN-2015 08:51
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_E2_01.dgn
SUBSTRUCTURE
(TYP. EACH PILE)
PLAN
COLLAR
CONCRETE
BOTTOM OF CAP
ELEVATION
CONCRETE COLLARS
{ PILES &
1’-4
�"
1’-6
"
2’-0"
FILL FACE
2’-0" ~ CONCRETE COLLAR
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
DRAWN BY : WJH 12/11
BAGGED STONE SHALL REMAIN IN PLACE UNTIL THE ENGINEER DIRECTS THAT
ACCUMULATIONS AT BAGGED STONE WHEN SO DIRECTED BY THE ENGINEER.
BAGS SHALL BE REMOVED AND REPLACED WHENEVER THE ENGINEER DETER-
MINES THAT THEY HAVE DETERIORATED AND LOST THEIR EFFECTIVENESS.
NO SEPARATE PAYMENT WILL BE MADE FOR THIS WORK AND THE ENTIRE
COST OF THIS WORK SHALL BE INCLUDED IN THE UNIT CONTRACT PRICE
BID FOR THE SEVERAL PAY ITEMS.
BAGGED STONE AND PIPE SHALL BE PLACED IMMEDIATELY AFTER COMPLETION
PIPE WILL NOT BE ALLOWED.
STEEL, CORRUGATED ALUMINUM ALLOY, OR CORRUGATED PLASTIC. PERFORATED
OF END BENT EXCAVATION. PIPE MAY BE EITHER CONCRETE, CORRUGATED
IT BE REMOVED. THE CONTRACTOR SHALL REMOVE AND DISPOSE OF SILT
CORROSION PROTECTION FOR STEEL PILES DETAIL
16
SHEET 3 OF 3
SEE ‘‘CORROSION PROTECTION FOR STEEL PILES DETAIL.’’)
(CONCRETE COLLAR NOT SHOWN FOR CLARITY.
DETAILS
CHECKED BY : AAC 12/11
45
60
45
60
POSITION OF PILE DURING WELDING.
DETAIL B
+10°
-0°
10°0°
BACK GOUGE
BACK GOUGEDETAIL A
DETAIL B
DETAIL A
PILE VERTICAL
OR VERTICAL
PILE HORIZONTAL
2’-9"
4’-0"
2’-3
"
2’-0
"
#4 S2
#4 S1
1’-2"
11"
#4 B3
3" HIGH B.B.
8"2" CL. (TYP.) 8"
8"
#4 S3
OVER PILES
4-#4 B2 @ 4" CTS.
1’-4� " 1’-4� "
{ #8 D1 DOWEL
4 S
PA
. @
7"
1’-10� "
1’-3"
CONST. JT.
#4 U1
#4 V2
2" CL.
11"
FILL FACE
1’-0"
2’-1� "
(TYP.)
1’-3" ABOVE CAP
TO PROJECT
#8 D1 DOWELS
1’-4� "1’-4� "
2’-9"
4�"
4�"
9"
1’-10�"
PAD (TYPE II) (TYP.)
ELASTOMERIC BRG.
2’-9" X 9" X 1"1’-0� "1’-0� "
{ BOX BEAM
STD. NO. EB_30_120S4_33BB
MINIMUM OF 3- ONE CUBIC
FOOT BAGS OF #78M STONE.
BAGS SHALL BE OF POROUS
FOR DRAINAGE
GRADE TO DRAIN
TOE OF SLOPE
6" ( MIN.) PIPEFABRIC,SECURELY TIED.
5"
6"
6"
6"
7�"
7�"
1’-7�"
REV. 8/14 MAA/TMG
17.BP.10.R.71
UNION
13+26.00 -L-
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
10/21/14
TEMPORARY DRAINAGE AT END BENT PILE SPLICE DETAILS
DETAIL ‘‘A’’
SECTION A-A
0"
TO
�"
0" TO � "
0"
TO
�"
0" TO � "
S-15CHECKED BY :
DATE :
DATE :
ASSEMBLED BY : N.D’AIUTO 10/21/14M.E.GILES 12/8/14
STEEL PILE
{ HP 12X53
STEEL PILE
{ HP 12X53
4-#9 B1
2-#9 B1
2-#9 B1
END BENT 2
ALL BAR DIMENSIONS ARE OUT TO OUT.
POUR #1
POUR #2
TOTAL CLASS A CONCRETE
BAR
B1
NO.
8
SIZE
#9
TYPE
1
LENGTH
43’-8"
WEIGHT
B2 28 #4 STR 410
B3 11 #4 STR 2’-5" 18
D1 20 #8 STR 2’-3"
H1 12 #5 2
K1 12 #4 STR 3’-5" 24
S1 54 #4 5 3’-2" 114
S2 54 #4 4 10’-5"
S3 20 #4 6 6’-6" 87
V1 61 #4 STR 7’-2" 292
149
V2 68 #4 STR 5’-3" 238
U1 34 #4 3’-7"7
120
K2 12 #4 STR 176
81
PART OF WINGS
BACKWALL & UPPER
1HK. HK.
HK
.
HK. HK.
1’-3" 1’-3"
4� " 4� "
4�"
1’-8" ~
2’-5"
2’-5"
2
11’-1"
41’-2"
10’-8"
H1
H2
10’-2"
3
5
4
6
5"
5"
3’-7
�"
8"
H2 12 #5 2 11’-6" 144
H3 24 #5 3 275
376
7
21’-11"
21’-11"
1’-5
�"
20.8
5.6
26.4
LBS.
C.Y.
C.Y.
C.Y.
BAR TYPES
1’-3" LAP
BILL OF MATERIAL
3,692
HP 12X53 STEEL PILES
LIN. FT.= 75NO: 5
PILE EXCAVATION IN SOIL
PILE EXCAVATION NOT IN SOIL
CLASS A CONCRETE BREAKDOWN
{ BEARING
FILL FACE
(EA. FACE)
#4 K2
(EA. FACE)
#4 B2
10"
10"
END BENT 2
11’-11"
11’-0"
REINFORCING STEEL
WINGS & COLLARS
CAP, LOWER PART OF
LIN. FT.= 31.00
LIN. FT.= 14.00
1,188
1/27/2015
![Page 17: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/17.jpg)
BAR NO. SIZE TYPE LENGTH WEIGHT
A2
A1
B1
B2
STR
STR
STR
STR
*
*
*
LBS.
LBS.
C. Y.
REINFORCING STEEL
REINFORCING STEEL
EPOXY COATED
CLASS AA CONCRETE
BAR NO. SIZE TYPE LENGTH WEIGHT
B1
B2
STR
STR
STR
STR
*
*
*
LBS.
LBS.
C. Y.
REINFORCING STEEL
REINFORCING STEEL
EPOXY COATED
CLASS AA CONCRETE
#4
#5
#6
#4
#5
#6
#4
#4
26
26
26
26
58
58
58
58
670
11’-1" 670
120° SKEW
15.6
15.6
APPROACH SLAB
BEGIN
APPROACH SLAB
END
N
N
9"
9"
-L-
CU
RB
CU
RB
(TOP OF SLAB) (2 BAR RUN)
11-#4A2 @ 1’-0" CTS.
11-#4A1 @ 1’-0" CTS.
(TOP OF SLAB) (2 BAR RUN)
(BOTTOM OF SLAB) (2 BAR RUN) (BOTTOM OF SLAB) (2 BAR RUN)
1’-3"
1’-3"
3"
1’-3"
1’-3"
3"
4"
4"
4"
4"
6" BEVEL
6" BEVEL
12’-1� " 12’-1� "
10� "
10� "
4� "
10� "
10� "
4� "
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTALSHEETS
STATE OF NORTH CAROLINA
RALEIGH
STATION:
COUNTY
DEPARTMENT OF TRANSPORTATION
12
3
427-JAN-2015 10:58
vpatel
S:\DPG3\DivisionLets\Div10\17BP10R71\Plans\17BP10R71_SD_AS_01.dgn
CURB DETAILS
CURB
SLAB
APPROACH
3’-1� "
FOR PRESTRESSED CONCRETE
BRIDGE APPROACH SLAB
(SUB-REGIONAL TIER)
A
NI
A
RD
OT
ED
RG
FLOW LI
NE
EP
OL
SF
OMOTTOB
OT
NOTE: IF THE APPROACH SLAB IS NOT CONSTRUCTED IMMEDIATELY
AFTER THE BACKFILLING OF THE END BENT EXCAVATION,
GRADE TO DRAIN TO THE BOTTOM OF THE SLOPE AND PROVIDE
EROSION RESISTANT MATERIAL, SUCH AS FIBERGLASS ROVING
OR AS DIRECTED BY THE ENGINEER TO PREVENT SOIL EROSION
AND TO PROTECT THE AREA ADJACENT TO THE STRUCTURE.
THE CONTRACTOR WILL BE REQUIRED TO REMOVE THESE
MATERIALS PRIOR TO CONSTRUCTION OF THE APPROACH SLAB.
TEMPORARY DRAINAGE DETAIL
CAP FLOW LINE ONLY WITHEROSION RESISTANT MATERIAL
BACKFILL EXCAVATION HOLEAND GRADE TO DRAIN
BRIDGE DECK
SLAB
APPROACH
12
"
FILL SLOPE
ELBOW
ELBOW
DRAIN
SLOPE
TEMPORARY
TOE OF FILL
SECTION S-S
SECTION R-R
EROSION RESISTANT MATERIAL
TO PI
PE INLET
GRADE TO
DRAIN
1’-6" MIN.
FLOW LINE
PLAN VIEW
TEMPORARY BERM AND SLOPE DRAIN DETAILS
R
TEMP. SLOPE DRAIN
1’-0"
MIN.
R
2’-0"
MIN
.
2’-6
" M
IN
.
S
S
4’-0"
EARTH DITCH BLOCK
À
2’-0"MIN.
NOTE:
TEMPORARY DRAINAGE PIPE, 12 INCHES IN DIAMETER.
THE SLOPE DRAIN SHALL CONSIST OF A NON-PERFORATED
MAT, OR 3) CONCRETE, AS DIRECTED BY THE ENGINEER.
PLANT MIX, TYPE 1 OR TYPE 2, MIN. 2" DEPTH, 2) EROSION CONTROL
EROSION RESISTANT MATERIAL SHALL BE EITHER 1) ASPHALT
AND PROVIDE EROSION RESISTANT MATERIAL AS SHOWN. THE
DRAIN. CONTRACTOR SHALL GRADE TO PIPE INLET
THE CONTRACTOR SHALL PROVIDE TEMPORARY BERM AND SLOPE
IMMEDIATELY AFTER THE CONSTRUCTION OF THE APPROACH SLAB,
MIN
.
2’-6
"
FOR EROSION CONTROL
CLASS ‘‘B" STONE
4’-0" MIN.
MATERIAL OVER PIPE
3" EROSION RESISTANT
(TO BE USED WHEN SHOULDER BERM GUTTER IS REQUIRED)
12" MIN.
SHOULDER
FUTURE
BLOCK
DITCH
EARTH
SLAB
APPROACH
END OF
BARSIZE
#4
#5
#6
EPOXY COATED UNCOATED
2’-0"
2’-6"
3’-10"
1’-9"
2’-2"
2’-7"
SPLICE LENGTHS
PROJECT NO.
BOX BEAM UNIT
8"
4"
NOTES
SECTION THRU SLAB
2’’ C
L.
2 : 1 SLOPEBARS
#4 ‘‘A’’
PROPOSED
PAVEMENT
ASPHALT
MIN
.
2"
@ 3’-0’’ CTS. ACROSS SLAB
5� ’’ CONTINUOUS HIGH CHAIR UPPER ( CHCU)
BARS
#4 ‘‘A’’BARS
#5 ‘‘B’’
BARS
#6 ‘‘B’’
3’-0"
BY THE CONTRACTOR)
(TO BE DETERMINED
OR STEEPER
1� : 1 SLOPE
NORMAL TO END BENT
ROADWAY
6"
1’-8"
STONE#78M
BACKFILL
APPROVED WIRE BAR
SUPPORTS @ 3’-0" CTS.
6"
8"
4" C
L.
1’-2
’’
GEOTEXTILE
BO
X B
EA
M
1’-1� "
PREVENT BOND
ROOFING FELT TO
2 LAYERS OF 30 LB.
ROD
2" BACKER
OPENING
1� "
2’-9"
1’-4"
APPROACH SLAB GROOVING IS NOT REQUIRED.
AND SHALL BE PAVED. SEE ROADWAY PLANS.
TO DRAIN THE WATER AWAY FROM THE FILL FACE OF THE BRIDGE
AREA BETWEEN THE WINGWALL AND APPROACH SLAB SHALL BE GRADED
DRAWINGS.
FOR THE 4" ~ DRAINAGE PIPE OUTLET(S), SEE ROADWAY STANDARD
BACKWALL FROM OUTSIDE EDGE TO OUTSIDE EDGE OF APPROACH SLAB.
#78M STONE BACKFILL IS TO BE CONTINUOUS ALONG FILL FACE OF
ACCORDANCE WITH STANDARD SPECIFICATIONS SECTION 1016.
#78M STONE BACKFILL (CLASS V SELECT MATERIAL) SHALL BE IN
SPECIFICATIONS SECTION 1056.
GEOTEXTILE SHALL BE TYPE 1 IN ACCORDANCE WITH THE STANDARD
PIPE, AND #78M STONE BACKFILL, SEE ROADWAY PLANS.
FOR BRIDGE APPROACH FILL INCLUDING GEOTEXTILE, 4" � DRAINAGE
PVC PIPE
SCHEDULE 40
4" ~ PERFORATED
STA. 13+80.66 -L-
(2 BAR RUN)
(BOTT. OF SLAB)
#4 A4
(2 BAR RUN)
(TOP OF SLAB)
#4 A3
END BENT 2
FILL FACE @
(TO CHORD)
118° -33’-39"
16’-7�
"
16’-6�"
* 2
9’-2
"
* 2
7’-
10" (
CL
EA
R R
OA
DW
AY
)
* 1
3’-1
1"
* 1
3’-11"
58-#5 B
1 @
6" C
TS
. (T
OP
OF
SL
AB
)
58
-#
6 B
2 @
6" C
TS
. (B
OT
TO
M O
F S
LA
B)
CU
RB
* 8
"* 8
"
CU
RB
* RADIAL DIMENSIONS
(TO CHORD)
118° -33’-39"
17’-3�"
16’-0"
7�"
3’-0"
16’-4�"
17’-8�"
8�"STA. 12+71.37 -L-
17’-1�"
17’-1�
"
N
N
* 1
3’-11"
* 1
3’-1
1"
58-#5 B
1 @
6" C
TS
. (T
OP
OF
SL
AB
)
58
-#
6 B
2 @
6" C
TS
. (B
OT
TO
M O
F S
LA
B)
* 2
7’-
10" (
CL
EA
R R
OA
DW
AY
)
* 2
9’-2"
* 8
"*
8"
(2 BAR RUN)
#4 A2
#4 A1 OR(2 BAR RUN)
#4 A4
#4 A3 OR
END BENT 1
FILL FACE @
(2 BAR RUN)
(TOP OF SLAB)
#4 A1
(TO CHORD)
121° -26’-19"
(TO CHORD)
121° -26’-19"
ARC OFFSETS ARE NEGLIGIBLE.
SEAL
23371
N
ORTH CAROLINA
PR
OFESSIONAL
ENGINEER
LETAP .A LU
PI
V
17’-10"
17’-9"
11’-1"
11’-8"
310
308
1016
1,324
980
302
300
1016
1,316
972
17’-5"
17’-3"
11’-8"
BILL OF MATERIAL
APRROACH SLAB AT EB 1
APRROACH SLAB AT EB 2
A3
A4
DESIGN ENGINEER OF RECORD: DATE :
DATE :
DATE :
CHECKED BY:
ASSEMBLED BY: N.D’AIUTO
M.E.GILES
N.D’AIUTO 12/8/14
12/8/14
10/22/14 S-16
16
SECTION N-NSHOULDER BERM GUTTER
END OF CURB WITHOUT
FOR EROSION CONTROL
CLASS ‘‘B’’ STONE
(2 BAR RUN)
(BOTT. OF SLAB)
#4 A2
PLAN @ END BENT 1 PLAN @ END BENT 2
2"
17BP.10.R.71
UNION
13+26.00 -L-
11-#4A3 @ 1’-0" CTS.
11-#4A4 @ 1’-0" CTS.
W.P. #2
W.P. #1
STA. 12+82.20 -L-
STA. 13+69.80 -L-
1/27/2015
![Page 18: This electronic collection of documents is provided for ... 10... · 4/6/2016 · 520 530 540 SPAN A PROPOSED GRADE END BENT 1 END BENT 2 G.P. EL. 525.63 STA. 12+72.58 -L-BEGIN FRONT](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb93323db793f5ba10a1b1f/html5/thumbnails/18.jpg)