think outside the box w ith g2 drip guard - rooftop solutions … · think outside the box w ith...

2
Advanced Filter Composite ® absorbs and traps grease and oil keeping them off your roofing system (See back for diagram of filter) Grease deflective flashing mounting assembly is constructed from 20 gauge galvanized steel Pre-assembled unit allows for quick and easy installation You Have A Problem… We Have A Solution. We Help You Comply We Help You Comply Think Outside the Box with G2 ® Drip Guard ® Standard grease collection boxes do not effectively contain grease Kitchen exhaust fans commonly located over low to moderate grease-producing kitchen equipment, such as ovens, ranges, roasters, rotisseries, smokers, kettles, steam cookers and low volume fryers accumulate grease which can drain onto your rooftop. Because the steel catch boxes typically used to collect this grease are not closed to the elements or rainproof, roofing systems are routinely damaged from the overflow of grease. This results in unnecessary liabilities, costly roof repairs, unsafe work areas, fire hazards and possible code violations. The N EW G2 ® Drip Guard ® Side Mount Rooftop Defense Systems ® are designed to fit all types of kitchen exhaust fans with low to moderate grease output from one side of the fan. The G2 ® Drip Guard ® repels rainwater and absorbs grease in its patented Advanced Filter Composite ® . The clean water passes freely onto the rooftop while grease stays trapped in the filter. The G2 ® Drip Guard ® is so effective at containing grease and oil from rooftop exhaust systems that Underwriters Laboratories Inc. has Listed it for effectiveness and safety. This is the most absorbent, noncombustible, rainproof, structurally sound, closed and Listed grease containment system on the market today. We guarantee it! DRIP GUARD ®

Upload: others

Post on 17-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Think Outside the Box w ith G2 Drip Guard - Rooftop Solutions … · Think Outside the Box w ith G2® Drip Guard® Standard grease collection box es do not effectively contain grease

Adva nced Filter Compos ite ®

absorbs and traps grease and oilkeeping them off your roofing system(See back for diagram of filter)

G rea se def lectiv e f la shingmounting assembly is constructedfrom 20 gauge galvanized steel

P re-a ssembled unitallows for quick and easyinstallation

Y o u H a v e A P r o b le m …W e H a v e A S o lu t io n .

W e HelpYou ComplyW e Help

You Comply

Think O uts ide the Box w ithG 2 ® Dr ip G ua rd ®

Sta nda rd grea se co llectionbox es do not effectiv e lyconta in grea se

Kitchen exhaust fans commonly located over low to moderate grease-producingkitchen equipment, such as ovens , ra nges , roa ster s , rotisser ies , smok ers ,k ettles , s tea m cook ers and low volume fr y er s accumulate grease whichcan drain onto your rooftop. Because the steel catch boxes typically used to collect thisgrease are not closed to the elements or rainproof, roofing systems are routinelydamaged from the overflow of grease. This results in unnecessary liabilities, costly roofrepairs, unsafe work areas, fire hazards and possible code violations.

The N EW G 2 ® Dr ip G ua rd ® S ide M ount Rooftop Defense Sy s tems ® aredesigned to fit all types of kitchen exhaust fans with low to moderate grease outputfrom one side of the fan. The G2® Drip Guard® repels rainwater and absorbs greasein its patented Advanced Filter Composite® . The clean water passes freely onto therooftop while grease stays trapped in the filter. The G2® Drip Guard® is so effectiveat containing grease and oil from rooftop exhaust systems that UnderwritersLaboratories Inc. has Lis ted it for effectiveness and safety. This is the mostabsorbent, noncombustible, rainproof, structurally sound, closed and Listed greasecontainment system on the market today. W e gua ra ntee it!

DRIPGUARD ®

Page 2: Think Outside the Box w ith G2 Drip Guard - Rooftop Solutions … · Think Outside the Box w ith G2® Drip Guard® Standard grease collection box es do not effectively contain grease

Top Pre-Filter— a pass-thru,noncombustible, self-extinguishing filterconstructed from an open cross sectionpolymer.

Advanced Filter Composite®

Transfer Layer— constructed frompolyolefin fiber. Designed for quick transferof oil based fluids to the absorption layers,while repelling rainwater. UV stabilityprotects the absorption layers fromdamaging sunrays.

Absorption Layer— constructed from anengineered open cell polyolefin fabric. Over72 layers of absorbent microfibers wick andcontain oil based fluids, while repellingrainwater. Absorption capacity is up to59 fluid ounces per square foot.

Barrier Layer— constructed from aclosed cell polymeric blend that providesa leak proof barrier.

Fire Shield— a galvanized steel, fire-proofbottom that protects the roof and buildingfrom any potential exhaust system firehazards.

Filter Components

1

2

3

Total Protection

For Information Call Toll Free:800.913.7034

Made in the U.S.A.U.S. Patent No’s 5,196,040 and 5,318,607. Other Patents Pending.

The easiest way to ensure that your property and roofing investmentsare protected is to incorporate the G2® Drip Guard® Side MountRooftop Defense Systems® into your rooftop equipment package.By using the G2® Drip Guard®, your property is guaranteed protectionfrom the damaging effects and hazards of rooftop grease and will alsomeet the new NFPA 96 code requirements.

For higher volume, grease-producing exhaust fan applications, such asbroilers, grills, griddles, woks and fryers, use the G2® GreaseGuard® XD for complete, UL Listed, four-sided grease containment.

2

1

3

Easy Installation and Maintenance

1. Place G2®Drip Guard® under fan drain spout.Align with top of curb and position G2®DripGuard® flashing under the curb cap.

2. Level the G2®Drip Guard®and screw flashingto the curb nailer with self-tappingscrews provided.

This high capacity filter systemtraps and absorbs up to onegallon of grease. Pre-cut filterreplacements are installed inseconds. Discard saturated filterin disposable bag provided.

Note: Unit dimensions are 21” length x 14” width. Model #G2-SM20

We Help You ComplyWe Help You ComplyNational Fire Protection Association

*NFPA 96 Standard for Ventilation Control and Fire Protection of CommercialCooking Operations 1998 Edition4-8.2.1 Rooftop terminations shall be arranged with or provided with the following:(c) The ability to drain grease out of any traps or low points formed in the fan orduct near the termination of the system into a collection container that is noncom-bustible, closed, rainproof, structurally sound for the service to which itis applied, and will not sustain combustion. A grease collection device that isapplied to exhaust systems shall not inhibit the performance of any fan.

Exception: Grease containers that are evaluated for equivalency with thepreceding requirements and listed as such.

*Reprinted with permission from NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial CookingOperations ©1998, National Fire Protection Association, Quincy, MA 02269. The reprinted material is not the completeand official position of the National Fire Protection Association on the referenced subject which is represented only bythe standard in its entirety.