thefusionof strength,design and performancesynthes.vo.llnwd.net/o16/llnwmb8/us mobile/synthes... ·...

7
The Fusion of Strength, Design and Performance Interbody Fusion Platform

Upload: others

Post on 10-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

The Fusion of

Strength, Designand Performance

Interbody Fusion Platform

• Contoured caudal and rostral surfaces conform to the anatomy

• Open architecture designed for load-sharing in implant

• Mid-line I-Beam increases construct strength

Anatomical fit for balanced anterior column support

• Bulleted nose facilitates easier insertion*

• Designed to address collapsed disc spaces

• Pyramidal teeth designed for higher resistance to migration*

• Patented lordotic design for sagittal balance in the oblique position

• 33% more bone graft area*

• Appropriate for both open and MIS TLIF approaches

* vs. competition. Data on file.

TLIF (TRANSFORAMINAL LUMBAR INTERBODY FUSION)

The DePuy Spine Interbody Fusion platform is designed to provide an

open architecture implant in a load-sharing environment. The strength,

design and performance of these implants and the variety within

the portfolio gives you a choice of powerful options for

your cervical and lumbar degenerative pathologies.

Interbody Fusion Platform

®

Lumbar Interbody System

Lumbar Interbody System

LEOPARD®

Self-distracting implants and instrumentsfor simplified cage insertion

• Contoured caudal and rostral surfaces conform to the anatomy

• Open architecture designed for load-sharing in implant

• Mid-line I-Beam increases construct strength

Anatomical fit for balanced anterior column support

• Bulleted nose facilitates easier insertion*

• Designed to address collapsed disc spaces

• Pyramidal teeth designed for higher resistance to migration*

• Patented lordotic design for sagittal balance in the oblique position

• 33% more bone graft area*

• Appropriate for both open and MIS TLIF approaches

* vs. competition. Data on file.

TLIF (TRANSFORAMINAL LUMBAR INTERBODY FUSION)

The DePuy Spine Interbody Fusion platform is designed to provide an

open architecture implant in a load-sharing environment. The strength,

design and performance of these implants and the variety within

the portfolio gives you a choice of powerful options for

your cervical and lumbar degenerative pathologies.

Interbody Fusion Platform

®

Lumbar Interbody System

Lumbar Interbody System

LEOPARD®

Self-distracting implants and instrumentsfor simplified cage insertion

• Inserter combines disc space distraction and insertion into a single step

• Large openings provide surface area for bone graft-to-endplate contact

• Multiple threaded insertion holes for surgical approach flexibility

• Chamfered edges designed for easy insertion

• Surface teeth designed to resist implant migration and/or retropulsion

• Large footprint offers optimal endplate coverage for maximum stability

• Contoured profile to fit the natural shape of disc space,allowing implant to correspond with cortical rim of endplate

• Multiple insertion holes allow for anterior or posterior approach

Innovative self-distracting inserter forsmooth and controlled cage insertion

Contoured profile for anatomical fit

PLIF (POSTERIOR LUMBAR INTERBODY FUSION)

ALIF (ANTERIOR LUMBAR INTERBODY FUSION)

Lumbar Interbody System

SABER®

Lumbar Interbody System

COUGAR®

• Open design allows for bonegraft-to-endplate contact

• Anatomical shape designed to fitnaturally in the cervical spine

• Simple and effective instrumentationfor preparation and insertion

Open architecture tomaximize graft volume

ACDF (ANTERIOR CERVICAL DISCECTOMY AND FUSION)

Cervical Interbody System

BENGAL®

The DePuy Spine family of interbody spinal

fusion implants are made of carbon fiber

reinforced polymer (CRFP) - a premier material.

Composed of 30% carbon fiber and 70% PEEK,

CFRP has a strength that allows for optimal

cage design resulting in an implant that

meets the structural requirements of anterior

column support, while optimizing the

fusion environment through an open,

load-sharing construct.

Strength• Strong enough to withstand in vivo loads with anoptimized stiffness for load-sharing

Open design• Maximized area for bone graft, lateralvascularization, and load-sharing

Proven Clinical Success• CFRP implants have over a decade of usein the spine

OPEN ARCHITECTURE DESIGNIN A LOAD-SHARING ENVIRONMENT

INDICATIONSCONCORDE®, COUGAR® and LEOPARD® SystemsThe CONCORDE, COUGAR and LEOPARD Systems are indicated for use as intervertebral body fusion devices in skeletally mature patients withdegenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by patient history and radiographic studies) at oneor two contiguous levels of the lumbar spine (L2-S1). Patients should have six months of non-operative treatment prior to surgery. These implants areused to facilitate fusion in the lumbar spine and are placed via either a PLIF (CONCORDE), TLIF (CONCORDE, LEOPARD) or anterior (COUGAR) approachusing autogenous bone. When used as interbody fusion devices these implants are intended for use with DePuy Spine supplemental internal fixation.The CONCORDE, COUGAR and LEOPARD Systems are indicated for use in the thoracolumbar spine (i.e., T1-L5) to replace a diseased vertebral bodyresected or excised for the treatment of tumors, to achieve anterior decompression of the spinal cord and neural tissues, and to restore the height of acollapsed vertebral body. These systems are also indicated for treating fractures of the thoracic and lumbar spine. These systems are designed to restorethe biomechanical integrity of the anterior, middle and posterior spinal column even in the absence of fusion for a prolonged period. When used as avertebral body replacement device these systems are intended for use with DePuy Spine supplemental internal fixation.BENGAL® SystemThe BENGAL System is indicated for use as an intervertebral body fusion device in skeletally mature patients with degenerative disc disease (defined asdiscogenic back pain with degeneration of the disc confirmed by patient history and radiographic studies) at one level of the cervical spine withaccompanying radicular symptoms. Patients should have six weeks of non-operative treatment prior to surgery. BENGAL implants are used tofacilitate fusion in the cervical spine (C2-T1) and are placed via an anterior approach using autogenous bone. When used as an interbody fusiondevice, DePuy Spine supplemental fixation may be used.The BENGAL System is indicated for use in the thoracolumbar spine (i.e., T1-L5) to replace a diseased vertebral body resected or excised forthe treatment of tumors, to achieve anterior decompression of the spinal cord and neural tissues, and to restore the height of a collapsedvertebral body. This system is also indicated for treating fractures of the thoracic and lumbar spine. This system is designed to restore thebiomechanical integrity of the anterior, middle and posterior spinal column even in the absence of fusion for a prolonged period. Whenused as a vertebral body replacement device this system is intended for use with DePuy Spine supplemental internal fixation.SABER® SystemThe SABER Lumbar I/F CAGE® System is indicated for an open posterior approach, using autogenous bone graft in patients withDegenerative Disc Disease (DDD) at one or two spinal levels from L2-S1 whose condition requires the use of interbody fusion,combined with posterolateral fusion (360° fusion) and posterior pedicle screw fixation. The Wedged SABER Lumbar I/F CAGE isindicated for an open posterior approach, using autogenous bone graft in patients with Degenerative Disc Disease (DDD) at one ortwo levels from L4-S1 whose condition requires the use of interbody fusion, combined with posterolateral fusion (360° fusion) andposterior pedicle fixation. These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s).DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies.Notice: There are labeling limitations for the use of the SABER Lumbar I/F CAGE System. See the package insert supplied withthis device for important information.Limited Warranty and Disclaimer: DePuy Spine products are sold with a limited warranty to the original purchaseragainst defects in workmanship and materials. Any other express or implied warranties, including warranties ofmerchantability or fitness, are hereby disclaimed.WARNING: In the USA, this product has labeling limitations. See package insert for complete information.CAUTION: USA Law restricts these devices to sale by or on the order of a physician.DEPUY SPINE™ and the DePuy Spine logo are trademarks of DePuy Spine, Inc.BENGAL®, CONCORDE®, COUGAR®, LEOPARD®, SABER®, VG1® and VG2® are registered trademarks of DePuy Spine, Inc.Not all products are currently available in all markets.© 2009 DePuy Spine, Inc. All rights reserved.To order, call DePuy Spine Customer Service (1-800-227-6633).

DePuy Spine, Inc.325 Paramount DriveRaynham, MA 02767USATel: +1 (800) 227-6633

www.depuy.com

IF28-00-000 11/09 JC/RPI

Self-distracting implantsand instruments

for simplified cage insertion

Also available from DePuy Spine throughdistribution agreement with LifeNet Health,

the Vertigraft® Allograft Bio-Implant products.

VG2® Cervical Allograft

VG1® ALIF Allograft

VG2® PLIF Allograft

VG2® TLIF Allograft

Anatomical fit for balancedanterior column support

Innovative self-distracting inserterfor smooth and controlled cage insertion

Contoured profile foranatomical fit

Open architecture formaximum graft volume

Lumbar Interbody System

Cervical Interbody System

BENGAL®

Lumbar Interbody System

SABER®

Lumbar Interbody System

COUGAR®

Lumbar Interbody System

LEOPARD®

Interbody Fusion Platform

®