the world of lapp - wire & cable · pdf filefor your individual project if you place...

28
THE WORLD OF LAPP Photovoltaic Solutions for the North American Market

Upload: vuongnguyet

Post on 12-Mar-2018

219 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

THE WORLD OF LAPPPhotovoltaic Solutions for the North American Market

Page 2: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com2

WELCOME

Please come in and look around. Irrespectiveof which cable, line, plug and accessory yourequire for your particular application, you willfind exactly what you need here. We havemore than 40,000 different standard articlesin stock. We also deliver within 24 or 48hours. Special tasks demand special solutions. In this case too, you need look nofurther than our company. In addition to thecomprehensive range of standard Lapp products, we can also offer you individualcable assemblies and the engineeringinvolved.

You should also be aware of the following:Lapp is one of the leading internationalsystem providers. Our brands are used inthe most varied of applications, branchesand global markets. One of our principlesstates: when striving for perfection weshould rely on no-one but ourselves. This iswhy we manufacture everything in our ownproduction sites. We also have numeroussales companies and logistics centersaround the world, which enable us to beclose to our customers. We’re somewherenear you too!

To contact your local Lapp GroupRepresentative send an email to:[email protected] or [email protected]

Page 3: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 3

Ideas that make the world go round 4

In use worldwide 5

Quality counts 5

Solar products from Lapp 6

Brand products for your solar units 7

EPIC® SOLAR 4 THIN 8

ÖLFLEX® SOLAR SOLUTIONS 10

ÖLFLEX® SOLAR XL multi 11

ÖLFLEX® SOLAR XLR 4703 12

EPIC® SOLAR 4 THIN 13

EPIC® SOLAR Module Box 14

Cable Accessories: Tools 15

SKINTOP® CLICK/SKINTOP® CLICK-R 16

SKINTOP® SLM/SKINTOP® SLRM 17

SKINTOP® SLN/SKINTOP® SL 18

SKINTOP® DIX-SELECTION CHARTS 19

SILVYN® RILL PA 6 21

SILVYN® Conduit & Tools 22

ÖLFLEX® FORTIS 23

ÖLFLEX® TRAY II 24

ÖLFLEX® TC 600 26

CONTENT

Page 4: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com4

Ideas that make the world go round

Since 1957 we have registered more than 100 patents, and we carry a delivery program of more than 40,000products, which are used wherever electrical energy is used to power, drive, light or control things. Most of thisalso happens out of sight. For example inside the Cheops pyramid in El Gîza. ÖLFLEX® cables are used there tosafeguard smooth operation of the air-conditioning units. We also equipped the K2 base camp at an altitude of5,000 meters. At -46° Celsius, we also clearly demonstrated that our products work even at the lowest of temperatures.

You will discover Lapp in up to 200 m long paper-making machines and in the 178 m high Singapore Flyer, theworld’s most spectacular big wheel. We are also on-board the Transrapid train in Shanghai and in navy sub-marines diving deep below the sea. At the opera house in Beijing we made everyone very happy, and we touredthe world recently with the Rolling Stones. We equipped international airports in London, Sofia and Munich with hundreds of kilometers of lines and we are out there listening inside one of the world’s largest radio telescopes,well beyond the frontiers of our own solar system.

And we play our part in using sun, wind and other green energy sources more efficiently – in the meantime Lappis one of the leading partners to companies in the application fields of photovoltaics, wind power, biomass andfuel-cell technology.

Page 5: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 5

In use worldwide

Wherever you wish to realize your photovoltaicproject – you can count on the performance ofour products. For example, in Bovera, Spain over5,000 solar modules have been installed over anarea of 24,700 m2. Here ÖLFLEX® SOLAR cableswith a total length of 20 km ensure perfect operation. But we are not only glad to be yourpartner for big projects, you can also count on usfor smaller systems.

Quality Counts

A wealth of characteristics make the componentsso popular among users: They are not only UVresistant, but also extremely weatherproof andtemperature resistant. In a nutshell – the brandproducts demonstrate their top performance indiverse applications around the world.

Page 6: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com6

Solar products from Lapp –System competence for photovoltaics:

Put your trust in a partner who offers you perfect system competence from a single source for cables, plugs and connectorsfor photovoltaics. With Lapp brand products you are fully equippedfor your individual project if you place importance on excellentquality and services.

Page 7: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 7

Brand products for your solar units:

The following products are used in the solar energy sector:

ÖLFLEX® SOLAR XL Multi

EPIC® SOLAR Module Box

EPIC® SOLAR THIN pre-assembled

Tools

SKINTOP® SLM/SLRM

SILVYN® RILL PA 6/ PA 6 SINUS

ÖLFLEX® FORTIS

SKINTOP® DIX

LAPP GROUP STUTTGART ÖLFLEX® FORTIS

SKINTOP® CLICK/ SKINTOP® CLICK-R

ÖLFLEX® TRAY II

LAPP GROUP STUTTGART ÖLFLEX® TRAY II

ÖLFLEX® TC 600LAPP GROUP STUTTGART ÖLFLEX® TC 600

ÖLFLEX® SOLAR XLR 4703

Page 8: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com8

EPIC® SOLAR 4 THINFunctional reliability and durability are two essential quality criteria for wiring systems in photovoltaics. TheSOLAR brand components from Lapp Group are UV resistant, waterproof and temperature resistant. Theyare used worldwide and ensure durable connections with effective energy transmission in major projects, aswell for small solar plants. Super-slim, super-effective, super-durable Backed up by in-depth expertise anddecades of experience in the use of cable systems under extreme environmental conditions – heat and cold,as well as mechanical and chemical stresses.

Zero-resistance cable connectionfor super-effective energy transmission.

High packing densitywith a super-flat 12 mm

Conductor cross-sectionsfrom 1.5 mm2 to 6 mm2

Zero-resistance cable connection byvirtue of an innovative welded joint

Page 9: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 9

EPIC® SOLAR 4 THIN puts the focuson panel producers’ quality requirements:

• No warming of the connector and therefore little aging and durable functional reliability• Plug and cable preassembled. Every part is tested!• Development according to international TÜV and UL standards

Cable tie optionintegrated

Module box made to measure!

4 mm connector systemwith double hook

Cable tie optionintegrated

When it comes to customer-orientation and flexibility, the sunalways shines at Lapp Group. For instance, we offer EPIC® SOLAR! connection boxes for weatherproof wiring, also as acustomized solution for your solar panels. Just ask us!

Page 10: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com10

ÖLFLEX® SOLAR SOLUTIONS - THE ONLY CHOICE FOR YOUR INSTALLATION

There are many reasons to use enhanced PV or Solar cable constructions rather than the minimum acceptable standards.

For the most part, PV wiring is exposed wiring when use on roof tops and/or solar farms. PV/Solar cableproducts utilizing an insulation layer and a separate jacket layer provide enhanced mechanical protection. (Improved protection against accidental damage, abrasion resistance, rodents, etc.)

PV wiring terminations are typically performed at the installation site with crimp style PV connectors.Typical minium approved wiring products are not fine stranded, and usually utilize bare copper susceptibleto corrosion/oxidation, resulting in higher resistance crimps.

PV/Solar cable products utilizing tinned coated copper and fine stranding provide enhanced longterm reliability from corrosion/oxidation and improved crimp connections due to the fine stranding.This results in consistent lower resistance connections and enhanced long term efficiency of thesystem.

Other considerations include the long term UV or Sunlight resistance of the wiring/cable. Many local testing standards currently do not provide any specific reference to real life service expectations from a ULor Sunlight exposure aspect. Based on our UV/Sunlight Resistance testing, and our global experiencein this market segment, Lapp products are designed for a sunlight service life expectancy of atleast 25 years.

Is your company socially responsible? If not you can help ensure you meet these requirements through theuse of Lapp ÖLFLEX® Solar Cables. ÖLFLEX® Solar cabling products are halogen-free ensuring a 100%environmentally green and safe solution for the entire life cycle of the installation, including decommissioning.

Page 11: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com

ÖLFLEX® SOLAR XL multiMultiple Rated and Cross-Linked Solar Cable for Weather-Proof Wiring of Photovoltaic Systems

ÖLFLEX® SOLAR XL multi is a single conductor, double insulated,cross-linked, halogen-free and flame retardant solar cable for photovoltaic installations, suitable for use in all seasons.

RECOMMENDED APPLICATIONS:Designed for outdoor connection of individual solar panels and connection of the panels with the inverter

ÖLFLEX® SOLAR XL multi Construction:Finely stranded tinned copper conductors, polyolefin insulation; black halogen-free cross linked polyolefin outer jacket.

Minimum Bending Radiusfor installation: 4 x cable diameter

Temperature RangeFixed Installation: -40oC to +120oC

Nominal Voltage: 600V (USE-2)1000V (RWU90)

Test Voltage: 4000V

Conductor Stranding: Fine Wire per VDE 0295, Class 5IEC 60228 Cl.5

Color Code: Black

Approvals: UL: USE-2c(UL): RWU90

TECHNICAL DATA:

Black14 AWG (2.5 mm2)

002658512 AWG (4 mm2)

002658610 AWG (6 mm2)

00265878 AWG (10 mm2)

00265886 AWG (16 mm2)

0026589

PartNumber

ConductorStranding

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

50 x 0.26

56 x 0.31

84 x 0.31

80 x .041

128 x .041

16

26

39

65

103

Nominal OuterDiameter

inches mm

PartNumber

ConductorStranding

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

Nominal OuterDiameter

inches mm

5.6

6.0

7.1

8.5

9.9

30

48

69

107

166

45

72

102

159

247

.220

.236

.280

.335

.390

Black-Coded14 AWG (2.5 mm2)

002659012 AWG (4 mm2)

002659110 AWG (6 mm2)

00265928 AWG (10 mm2)

00265936 AWG (16 mm2)

0026594

50 x 0.26

56 x 0.31

84 x 0.31

80 x .041

128 x .041

16

26

39

65

103

5.6

6.0

7.1

8.5

9.9

30

48

69

107

166

45

72

102

159

247

.220

.236

.280

.335

.390

APPLICATION ADVANTAGE:• Halogen-free and flame retardant• UV and Ozone resistant• Weather and abrasion resistant• Wide temperature range• Coded version to differentiate between positive & negative• Suitable for direct burial• Fine stranding-more flexible- easier routing and installation

Availability:

Standard put-ups are 500m. Other put upsare available upon request.

EPIC® SOLAR Strip Tool

21920120

Part Number

21920122

Blade Part Number

11

Page 12: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com12

ÖLFLEX® SOLAR XLR 4703UL Listed PV Wire for Photovoltaic Systems

ÖLFLEX® SOLAR XLR 4703 is a single conductor, double insulated,cross-linked, halogen-free and flame retardant solar cable for photovoltaic installations, suitable for use in all seasons.

RECOMMENDED APPLICATIONS:Designed for outdoor connection of individual solar panels and connection of the panels with the inverter

ÖLFLEX® SOLAR XLR 4703 Construction: (Black)Finely stranded tinned copper conductors, cross linked copolymer red insulation, black halogen-free cross linked polyolefin outer jacket.

Minimum Bending Radiusfor installation: 4 x cable diameter

Temperature RangeFixed Installation: -40oC to +90oC

Rated Voltage: 600V UL

Test Voltage: 6500V AC

Conductor Stranding: Fine Wire per VDE 0295, Class 5IEC 60228 Class 5

Color Code: Other colors on available upon request

Approvals: UL 4703 (PV wire)VW-1 UL 1581NFPA 70 Article 690.31

TECHNICAL DATA:

Black Jacket14 AWG (2.5 mm2)

002713012 AWG (4 mm2)

002713310 AWG (6 mm2)

00271368 AWG (10 mm2)

00271396 AWG (16 mm2)

0027142

PartNumber

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

16

26

39

65

103

Nominal OuterDiameter

inches mm

PartNumber

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

Nominal OuterDiameter

inches mm

5.9

6.3

6.9

8.9

10.2

37

47

62

106

153

55

69

92

158

228

.232

.248

.272

.350

.402

Red Jacket14 AWG (2.5 mm2)

002713112 AWG (4 mm2)

002713410 AWG (6 mm2)

00271378 AWG (10 mm2)

00271406 AWG (16 mm2)

0027143

16

26

39

65

103

5.9

6.3

6.9

8.9

10.2

37

47

62

106

153

55

69

92

158

228

.232

.248

.272

.350

.402

APPLICATION ADVANTAGE:• Halogen-free and flame retardant• UV and Ozone resistant• Weather resistant• Wide temperature range• Abrasion resistant• Fine stranding, more flexible, easier routing and installation

ÖLFLEX® SOLAR XLR 4703 Construction: (Red) Finely stranded tinned copper conductors, cross linked copolymer red insulation, red halogen-free cross linked polyolefin outer jacket.

Availability:

Standard put-ups are 500m. Other put upsare available upon request.

ÖLFLEX® SOLAR XLR 4703 (UL) PV WIRE 600V VW-1 SUNLIGHT RESISTANT RoHSLAPP KABEL

ÖLFLEX® SOLAR XLR 4703 (UL) PV WIRE 600V VW-1 SUNLIGHT RESISTANT RoHSLAPP KABEL

EPIC® SOLAR Strip Tool

21920120

Part Number

21920122

Blade Part Number

RPV & RPVUApproval inProgress

2kV v ersion will be

available soon

Page 13: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 13

EPIC® SOLAR 4 THIN male with cable ÖLFLEX® SOLAR XLR 44428100 44428101 44428102 44428103EPIC® SOLAR 4 THIN male with cable ÖLFLEX® SOLAR XL multi 44428108 44428109 44428110EPIC® SOLAR 4 THIN female with cable ÖLFLEX® SOLAR XLR 44428104 44428105 44428106 44428107EPIC® SOLAR 4 THIN female with cable ÖLFLEX® SOLAR XL multi 44428111 44428112 44428113

Part Number AWG (mm2)

16 AWG (1.5 mm²)14 AWG (2.5 mm²)12 AWG (4 mm²)10 AWG (6 mm²)

16 AWG (1.5 mm²)14 AWG (2.5 mm²)12 AWG (4 mm²)

16 AWG (1.5 mm²)14 AWG (2.5 mm²)12 AWG (4 mm²)10 AWG (6 mm²)

14 AWG (2.5 mm²)12 AWG (4 mm²)10 AWG (6 mm²)

Rated Current in A

Copper kg/1000

pcs.

StandardPackSize

Length in m

16212429

212429

16212429

212429

14.424.038.457.6

24.038.457.6

14.424.038.457.6

24.038.457.6

100100100100

100100100

100100100100

100100100

1111

111

1111

111

Temperature Range: -40oC to +105oC

Rated Voltage: 1000V AC/DCRated Impulse Voltage: 8kV

Pollution Degree: 3

Contact Resistance: <0.2m OHM

IP Protection: IP68 (10H/1M)Protection Class IICycle of Mechanical Operation 100

TECHNICAL DATA:

EPIC® SOLAR 4 Thin4mm connector system with double hook

EPIC® SOLAR THIN M pre-assembled

EPIC® SOLAR THIN F pre-assembled

BENEFITS:• Unresistant cable connection for efficient power transmission• Innovative, patented pending contact system, current leaves the connection cool

• High reliability and longevity by welded bonding• Extra Thin 12mm for high density packing

APPLICATION RANGE:• Pre-assembled connector cables for weather proof cabling of Photovoltaic systems

PRODUCT FEATURES:• 4mm connector system with double hook• Pre-assembled with 100% automatic control• Wide range of wire sizes from 1.5mm² up to 6mm²• TÜV Rheinland and UL/CSA in preparation

Page 14: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com14

EPIC® SOLAR Module BoxJunction Boxes for Weather Proofing Cabling for Photovoltaic Systems

APPLICATION RANGE:• The Module Box is used to glue on the backside of the solar

modules. The ribbon bands are terminated in the Module Box• For further cabling the pre-assembled solar cables, like EPIC® SOLAR 4 THIN or EPIC® SOLAR are terminated at the Module Box

PRODUCT FEATURES• EPIC® SOLAR Module Box: Rugged junction boxes for cabling of the solar modules with ÖLFLEX® SOLAR cable

• Dimensions (WxHxD): 118 x 28,5 x 109 mm• Housing material: PPO/PPS• CSA/UL: in preparation

EPIC® SOLAR Module Box 44428043 44428044EPIC® SOLAR Module Box with cable and EPIC® plug connector 44428045 44428046EPIC® SOLAR Module Box with cable and EPIC® Solar 4 Thin 44428062 44428063

Part Number Description

EPIC® SOLAR ST 200 3DEPIC® SOLAR ST 200 6D

EPIC® SOLAR ST200 XL multiEPIC® SOLAR ST200 XL multi

EPIC® SOLAR ST200 4 THIN XLR TFEPIC® SOLAR ST200 4 THIN XLR TF

ConnectionType

Lengthin mm

StandardPackSize

Cable Clampingrange, mm

Assembled with 3 bypass diodesAssembled with 6 bypass diodes

Pre-assembled with solar cablesPre-assembled with solar cables

Pre-assembled with solar cablesPre-assembled with solar cables

1.01.0

1.01.0

100100

100100

100100

3.7 - 7.13.7 - 7.1

--

--

Cross section in mm2

max. 6 mm2

max. 6 mm2

12 AWG (4 mm2)10 AWG (6 mm2)

12 AWG (4 mm2)10 AWG (6 mm2)

Temperature Range: -40oC to +105oC

Rated Voltage: 1000V AC/DCRated Impulse Voltage: 8kV

Pollution Degree: 3

Contact Resistance: <0.2m OHM

IP Protection: IP68 (10H/1M)Protection Class IICycle of Mechanical Operation 100

TECHNICAL DATA:

Page 15: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 15

BENEFITS:• Cuts copper and aluminum cables up to 20 mm outer diameter• Low force due to favorableness transmission ratio and new blade geometry• Easy, clean cut when operating with one hand

PRODUCT SPECIFICATIONS:• For single and multi-wire copper and aluminum cables• Pre and after cut (1st and 2nd blade) allows cables with an external outer diameter up to 20 mm to be cut

• Not suitable for steel wire and hard extruded copper wire

BENEFITS:Special stripping tool for high quality dismantling of single cores

PRODUCT SPECIFICATIONS:Applicable with a great variety of insulations differing in hardness and dimension

TOOL DESIGN:• Compact construction, easy to handle• Chrome-plated with plastic handle cover

CABLE ACCESSORIES: TOOLS

Universal Stripping Tool

Part Number

Cutting Rangeø

AWG (mm)

StandardPack Size

121920120

BladePart

Number

21920122 16 AWG to 10 AWG (1.5 - 6 mm)

KS-20

Part Number

Weightkg

Lengthin mm

200

StandardPack Size

162120045

For Outerø mm

20 .300

Page 16: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com16

SKINTOP® CLICK/ CLICK-RLiquid Tight, Non-Metallic Strain Relief with Quick “Click” Insertion System

SKINTOP® CLICK is an innovative cable insertion system that provides fast, highly flexible assembly. Easy snap in place installation results in fixed, centered, strain relief with maximumprotection in seconds.

RECOMMENDED APPLICATIONS:Applications where locknut installation is difficult to reach orsecure, such as dual wall enclosures and temperature controlledassemblies where insulation is used.

APPLICATION ADVANTAGE:• Up to 70% installation time savings due to innovative CLICK system

• Ideal for hard to reach dual wall enclosures and limited access spaces

• Reduced inventory as no locknuts are required• The heavy duty SKINTOP® design provides great pullout strength and very reliable strain relief

• Superior integrated locking mechanism includes aninternal ratchet for vibration proof protection

Color: Black (RAL 9005), UV Resistant Gray (RAL 7001)

Protection: IP 68, 5 bar

Materials:Body: Special PolyamideSeal: Special Elastomer

Temperature range: -20O C to +100O C

TECHNICAL DATA:

SKINTOP® CLICK: Liquid Tight, Non-Metallic Strain Relief with Metric Threads

5311292353112882531128835311288453112924

Part NumberBlack Gray

Clamping RangeøF

inches

SW1/ SW2Wrenching Flats

inches

0.591/ 0.7090.748/ 0.8660.984/ 1.0631.181/ 1.3391.417/ 1.575

Thread Type &Size

COverall Length

inches

StandardPackSize

DThread Length

inches

M-12M-16M-20M-25M-32

UL Status

RRLLL

.138 - .276

.197 - .354

.276 - .512.354 - .669.433 - .827

5311292153112876531128775311287853112922

1.5751.6541.7911.9092.165

5050252525

0.3150.3150.3150.3150.315

MHoleinches

0.484 (-.008)0.642 (-.008)0.799 (-.008)0.996 (-.008)1.272 (-.008)

SWall Thickness

inches

Part NumberBlack Gray

Clamping RangeøF

inches

SW1/ SW2Wrenching Flats

inchesThread Type &

Size

COverall Length

inches

StandardPackSize

DThread Length

inchesUL

Status

MHoleinches

SWall Thickness

inches

.039 - .157

.039 - .157

.039 - .157

.039 - .157

.039 - .157

* Includes 1 disassembly tool per pack

SKINTOP® CLICK-R: Liquid Tight, Non-Metallic Strain Relief with Reducer Bushing & Metric Threads

5311292953112885531128865311288753112931

0.591/ 0.7090.748/ 0.8660.984/ 1.0631.181/ 1.3391.417/ 1.575

M-12M-16M-20M-25M-32

RLLLR

.039 - .197

.157 - .276

.197 - .394

.236 - .512

.276 - .591

5311292753112879531128805311288153112928

1.5751.6541.7911.9092.165

5050252525

0.3150.3150.3150.3150.315

0.484 (-.008)0.642 (-.008)0.799 (-.008)0.996 (-.008)1.272 (-.008)

.039 - .157

.039 - .157

.039 - .157

.039 - .157

.039 - .157

UL Status: R = Recognized; L = Listed

Page 17: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 17

Protection: 70 PSISeal: IP 68, 5 Bar (Exceeds NEMA 6/ 6P Pressure rating) IP 69K

Temperature range: Static: -40O C to +100O CDynamic: -20O C to +100O C

Materials:Body: PolyamideBushing: CRLocknuts: Included

Color: - Black (RAL 9005) UV Resistant

- Gray (RAL 7001)

TECHNICAL DATA:

SKINTOP® SLM: Liquid Tight, Non-Metallic Strain Relief Cable Gland with Metric Threads

SKINTOP® SLRM: Liquid Tight, Non-Metallic Strain Relief Cable Gland with Reducer Bushing

SKINTOP® SLM/ SLRMLiquid Tight, Non-Metallic Strain Relief Cable Gland with Metric Threads

SKINTOP® SLM/ SLRM is a durable, liquid tight, easy toassemble strain relief cable gland with Metric threadsthat is universally suited for all types of machinery &equipment, including automation, motion control,process control and robotics.

APPLICATION ADVANTAGE:• The heavy duty SKINTOP® design provides great pullout strength and very reliable strain relief

• Superior integrated locking mechanism includes an internal ratchet for vibration proof protection

• Multi-trapezoidal thread requires just one twist to tighten• Generous high quality neoprene bushing provides a liquid tight and dust proof, hermetic seal

• Economical solution that covers a large clamping range with only 8 sizes

S2507S2509S2513S2516S2521S2529S2536S2542

Part NumberBlack Gray

ULStatus

Clamping RangeøF

inches

RRLLLLLL

SWWrenching Flats

inches

0.5910.7480.9841.1811.4171.8112.1652.598

Thread Type & SizeC

Overall Lengthinches

StandardPackSize

Weight 100 pcs.

lbs.

DThread Length

inches

M-12X1.5M-16X1.5M-20X1.5M-25X1.5M-32X1.5M-40X1.5M-50X1.5M-63X1.5

0.138 - 0.2760.177 - 0.3940.276 - 0.5120.354 - 0.6690.433 - 0.8270.748 - 1.1021.063 - 1.3781.339 - 1.772

S1507S1509S1513S1516S1521S1529S1536S1542

1.1811.3391.4571.5751.8502.0472.4412.795

10010010050251055

1.001.502.503.506.00

10.5017.5025.50

.315

.315

.354

.394

.394

.394

.472

.472

S2607S2609S2613S2616S2621S2629S2636S2642

Part NumberBlack Gray

ULStatus

Clamping RangeøF

inches

RRLLLLLL

SWWrenching Flats

inches

0.5910.7480.9841.1811.4171.8112.1652.598

Thread Type & SizeC

Overall Lengthinches

StandardPackSize

Weight 100 pcs.

lbs.

DThread Length

inches

M-12X1.5M-16X1.5M-20X1.5M-25X1.5M-32X1.5M-40X1.5M-50X1.5M-63X1.5

0.039 - 0.1970.079 - 0.2760.197 - 0.3940.236 - 0.5120.276 - 0.5910.591 - 0.9060.866 - 1.1421.102 - 1.535

S1607S1609S1613S1616S1621S1629S1636S1642

1.1811.3391.4571.5751.8502.0472.4412.795

10010010050251055

1.001.502.503.506.00

10.5017.5025.50

.315

.315

.354

.394

.394

.394

.472

.472

UL Status: R = Recognized; L = Listed

Page 18: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com18

S2138S2112S2134S2101

RLLL

0.7480.9451.2991.654

.138 - 0.315 .197 - 0.472 .512 - 0.709 .748 - 1.000

S1138S1112S1134S1101

1.6931.7722.0872.362

1001005025

2.002.505.509.00

.591

.591

.591

.591

S2107S2109S2111S2113S2116S2121S2129S2136S2142S2148

RRRLLLRLRL

0.5910.7480.8660.9451.0631.2991.6542.0872.3622.559

PG-7PG-9PG-11PG-13PG-16PG-21PG-29PG-36PG-42PG-48

0.098 - 0.2560.138 - 0.3150.157 - 0.3940.236 - 0.4720.354 - 0.5510.512 - 0.7090.551 - 0.9840.945 - 1.2601.378 - 1.4961.535 - 1.732

S1107S1109S1111S1113S1116S1121S1129S1136S1142S1148

1.2601.4171.4961.6141.7321.9292.2052.5982.6772.717

1001001001005050251055

1.001.502.002.503.005.008.5017.5024.0029.00

.315

.315

.315

.354

.394

.433

.433.512.512.551

PG Only

NPT-3/8"NPT-1/2"NPT-3/4"NPT-1"

SKINTOP® SLN: NPT Threads

SKINTOP® SL: PG ThreadsPart Number

Black Gray

ULStatus

Clamping RangeøF

inches

SWWrenching Flats

inches

Thread Type & Size COverall Length

inches

StandardPackSize

Weight 100 pcs.

lbs.

DThread Length

inches

Part Number

Black Gray

ULStatus

Clamping RangeøF

inches

SWWrenching Flats

inches

Thread Type & Size COverall Length

inches

StandardPackSize

Weight 100 pcs.

lbs.

DThread Length

inches

SKINTOP® SLN & SLLiquid Tight, Vibration Proof, Strain Relief Cable Gland with NPT or PG Threads

Protection: 70 PSISeal: IP 68, 5 Bar (Exceeds NEMA 6/ 6P Pressure rating) IP 69K

Temperature range: Static: -40O C to +100O CDynamic: -20O C to +100O C

Materials:Body: PolyamideBushing: CRLocknuts: Included

Color: - Black (RAL 9005) UV Resistant

- Gray (RAL 7001)

TECHNICAL DATA:

Page 19: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 19

SKINTOP® DIX INSERTS FOR ÖLFLEX® SOLAR XL multiSKINTOP® DIX Bushing Selection Table for Combiner Box Entrance

#

of Cables

Bushing Size

Metric DIXPN

Metric

CLICK

Metric Thread with Locknut

22334568

-M32M25M32M32-

M40M50

-53332270533253705333237053332470

-5334067053350870

-53112924531128845311292453112924

---

-S2521S2516S2521S2521

-S2529S2536

Bushing Size

DIXPN

PG Thread withLocknut

NPTThread

NPTLocknut

PG 21/ NPT 1/2”PG 21 / NPT 3/4”PG 21 / NPT 3/4”

-PG 29 / NPT 1” PG 29 / NPT 1”

--

536212705362127053621370

-5362947053629570

--

-S2121S2121

-S2129S2129

--

53800609S2134S2134

-S2101S2101

--

911371911372911372

-911373911373

--

Metric DIX NBR Options PG & NPT Silicone DIX Bushing Options

ÖLFLEX® SOLAR XL Multi 1- AWG Part # 0026586 (6 mm diameter)

#

of Cables

Bushing Size

Metric DIXPN

Metric

CLICK

Metric Thread with Locknut

223445816

M20M25M25-

M32M32M40M50

533202605332526053325360

-53332460533325605334086053350166

531128835311288453112884

-5311292453112924

--

S2513S2516S2516

-S2521S2521S2529S2536

Bushing Size

DIXPN

PG Thread withLocknut

NPTThread

NPTLocknut

PG 16-

PG 16PG21/NPT 1/2PG 21/NPT 3/4

---

53616260-

536163605362146053621460

---

S2116-

S2116-

S2121---

---

53800609S2134

---

---

911371911372

---

Metric DIX NBR Options PG & NPT Silicone DIX Bushing Options

TECHNICAL DATA:

Materials: NBR (Rubber)

Temperature: -40°C to +100°C

Seal: IP 54 IP 68 when all holes are optimally filled.

Special shapes available on request. Consult factory for details

TECHNICAL DATA:

Color: Natural

Materials: Silicone

Temperature: -30°C to +100°C

Seal: IP 54 IP 68 when all holes are optimally filled.

Metric DIX PG/NPT DIX

NOTES:

1) PG and Metric SKINTOP® cable glands are provided with a locknut.

2) If not all of the bushing holes are filled with cables, SKINTOP® DIX DV inserts must be added to achieve IP68.

10 AWG - Lapp PN 53100007

12 AWG - Lapp PN 53100006

3) The black DIX NBR bushings are preferred for solar applications as they contain UV stabilizers.

ÖLFLEX® SOLAR XL Multi 10 AWG Part # 0026587 (7.1 mm diameter)

Page 20: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com20

SKINTOP® DIX INSERTS FOR ÖLFLEX® SOLAR XLR 4703SKINTOP® DIX Bushing Selection Table for Combiner Box Entrance

ÖLFLEX® SOLAR XLR 4703 (UL) PV WIRE 600V VW-1 SUNLIGHT RESISTANT RoHSLAPP KABEL

ÖLFLEX® SOLAR XLR 4703 (UL) PV WIRE 600V VW-1 SUNLIGHT RESISTANT RoHSLAPP KABEL

#

of Cables

Bushing Size

Metric DIXPN

Metric

CLICK

Metric Thread with Locknut

223445816

M20M25M25-

M32M32M40M50

533202605332526053325360

-5333246053325605334086053350166

531128835311288453112884

-5311292453112924

--

S2513S2516S2516

-S2521S2521S2529S2536

Bushing Size

DIXPN

PG Thread withLocknut

NPTThread

NPTLocknut

PG 16-

PG 16PG 21/ NPT 1/2”PG 21/ NPT 3/4”

---

53616260-

536163605362146053621460

---

S2116-

S2116-

S2121---

---

53800609S2134

---

---

911371911372

---

Metric DIX NBR Options PG & NPT Silicone DIX Bushing Options

14 AWG (5.9mm) Part # 0027130/0027131 & 12 AWG (6.3mm) Part # 0027133/0027134

#

of Cables

Bushing Size

Metric DIXPN

Metric

CLICK

Metric Thread with Locknut

22334568

-M32M25M32M32-

M40M50

-53332270533253705333237053332470

-5334067053350870

-53112924531128845311292453112924

---

-S2521S2516S2521S2521

-S2529S2536

Bushing Size

DIXPN

PG Thread withLocknut

NPTThread

NPTLocknut

PG 21/ NPT 1/2”PG 21/ NPT 3/4”PG 21/ NPT 3/4”

-PG 29/ NPT 1”PG 29/ NPT 1”

--

536212705362127053621370

-5362947053629570

--

-S2121S2121

-S2129S2129

--

53800609S2134S2134

-S2101S2101

--

911371911372911372

-911373911373

--

Metric DIX NBR Options PG & NPT Silicone DIX Bushing Options

10 AWG (6.9mm) Part # 0027136/0027137

#

of Cables

Bushing Size

Metric DIXPN

Metric

CLICK

Metric Thread with Locknut

22345

M32M40-

M40M40

5333229053340290

-5334049053340590

53112924----

S2521S2529

-S2529S2529

Bushing Size

DIXPN

PG Thread withLocknut

NPTThread

NPTLocknut

PG 29/ NPT 1”-

PG 29/ NPT 1”PG 29/ NPT 1”

-

53629290-

5362939053629490

-

S2129-

S2129S2129

-

S2101-

S2101S2101

-

911373-

911373911373

-

Metric DIX NBR Options PG & NPT Silicone DIX Bushing Options

8 AWG (8.9mm) Part # 0027139/0027140

#

of Cables

Bushing Size

Metric DIXPN

Metric

CLICK

Metric Thread with Locknut

3 M40 53340310 - S2529

Bushing Size

DIXPN

PG Thread withLocknut

NPTThread

NPTLocknut

- - - - -

Metric DIX NBR Options PG & NPT Silicone DIX Bushing Options

6 AWG (10.2mm) Part # 0027142/0027143

NOTES:

1) PG and Metric SKINTOP® cable glands are provided with a locknut.

2) If not all of the bushing holes are filled with cables, SKINTOP® DIX DV inserts must be added to achieve IP68.

14 and 12 AWG - Lapp PN 53100006

10 AWG - Lapp PN 53100007

8 AWG - Lapp PN 53100008

3) The black DIX NBR bushings are preferred for solar applications as they contain UV stabilizers.

Page 21: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 21

Color: Black or Gray

Protection: IP 68

Materials: Polyamide Halogen & Silicone Free UL 94 V0 Temperature range: -40O C to +115O C

TECHNICAL DATA:

SILVYN® RILL PA 6: Non-Metallic Flexible Conduit

SILVYN® KLICK-G

SILVYN® KLICK-W

The SILVYN® RILL PA 6 is a flexible, non-metallic corrugated conduit suitable for use in various industrial applications. It isresistant to liquids, oils and gases, and highly resistant to acidsand solvents.

APPLICATION ADVANTAGES:• Halogen-free , flame retardant and self-extinguishing• Durable, long lasting conduit that is rugged yet flexible• For use in controls, moving machine parts, motor and internal connections, as well as industrial, medical and electrical applications

SILVYN® RILL PA 6Non-Metallic Flexible Quick Connect Conduit Systems

617469356174694561746955617470156174696561746975617469856174699561747005

Part NumberBlack Gray

Outer Diameterinches mm

617469396174694061746950617470106174696061746970617469806174699061747000

.394.512.622.728.8351.1221.3581.6732.146

10.013.015.818.521.228.534.542.554.5

Inner Diameterinches mm

.256

.394

.472.563.650.9061.1421.4171.890

6.510.012.014.316.523.029.036.048.0

Bend Radiusinches mm

.512.787

1.3781.5751.7722.1652.5593.5433.937

Conduit CoilPut-UpsFeet

Thread Type & Size for Fittings

NPT PG Metric

164164164164164164828282

NPT-1/4”NPT-1/4”NPT-3/8”

--NPT-1/2”NPT-3/4”NPT-1”NPT-1-1/4”NPT-1-1/2”

PG-7PG-9PG-11PG-13PG-16PG-21PG-29PG-36PG-48

M-10X1.0M-12X1.5M-16X1.5

--M-20X1.5M-25 X1.5M-32X1.5M-40X1.5M-50X1.5

1320354045556590

100

Page 22: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com22

SILVYN® RILL PA 6 SINUS Polyamide Conduit

61806550618065556180656061806565618065706180657561806580

Part NumberFitting for Holder

SILVYN®

FCL 10/ 55506905-

FCL 13/ 55506915FCL 16 / 55506925FCL 21/ 55506935SPLIT COS 20/ 61806710FCL 28/ 5506945

Inside Diametermm

StandardPack Rings

mm

6.78.49.912.216.621.323.2

Outside Diametermm

10.011.413.015.721.225.428.3

50505050505050

SILVYN® CONDUIT & TOOLS

Material: PA6 heat modified Cadmium free Halogen-free

Color: Black, UV Resistant & Weather proof

Temperature range: -40O C up to +140O C

TECHNICAL DATA:

SILVYN® COV

Cable Guide Tool- Cable pulling tool for SILVYN® RILL PA 6 SINUS

61830340618303506183036061830370

Part Number TypeStandardPack Rings

mm

STKP 8STKP 15STKP 20STKP 25

Cable Bundlingmm

6 - 910 - 1617 - 2121 - 28

1111

APPLICATION RANGE: Cable pull-in tool for SILVYN� RILL PA6 SINUS

BENEFITS:Proper and safe cutting to length of plastic conduits

APPLICATION RANGE:Conduit shears for non-metallic conduit, e.g. parallel corrugated protective conduit.

SILVYN® CC01

Part Number

Cutting Rangeø mm Standard

Pack Size

161722285 0 - 45

Page 23: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 23

ÖLFLEX® FORTISFlexible & Oil Resistant Tray Cable with UL/CSA -40oC Flexible/ -55oC Stationary

18 AWG (19/30) 1.00 mm2

331803 331804 331805 331807 331809 331812 331818 33182516 AWG (28/30) 1.50 mm2

331603 331604 331605 331607 331609 331612 331616 331618 33162514 AWG (46/30) 2.50 mm2

331403 331404 331405 331407

PartNumber

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

34579121825

3457912161825

3457

192531445675113156

2736456482

109145163227

456075

105

Nominal OuterDiameter

inches mm

PartNumber

Number of Conductors

includes ground

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

Nominal OuterDiameter

inches mm

7.58.18.89.5

10.912.114.917.2

8.38.99.7

10.512.114.415.816.618.8

9.210.010.811.81

576677

100112171245322

698398127171220271289397

87107128169

8598115149167255365479

103124146189255328403431592

130159191252

.297

.320

.346.373.429.477.587.677

.325.351.381.412.476.565.621.652.741

.362

.392

.427

.463

331409 331412 331418 33142512 AWG (56/.0117) 4 mm2 331204 331205 33120710 AWG (82/.0117) 6 mm2 331003 331004 331005 3310078 AWG (74/.0159) 10 mm2

330804 3308056 AWG (119/.0159) 16 mm2

330604 3306054 AWG (413/30) 21 mm2

3304042 AWG (66/30) 33.7 mm2

330204 330205

9121825

457

3457

45

45

4

45

135179269374

100125176

110147184257

245306

393491

541

9031068

4.516.218.722.5

11.712.814.8

12.714.716.017.4

17.9 19.6

22.824.9

27.8

32.335.8

225308439587

152187258

222265317443

412518

580725

952

13941749

335459654874

226279384

330394472661

615771

8641080

1418

20772606

.571.636.737.886

.460

.503.581

.500.578.631.686

.703

.772

.899

.982

1.094

1.2721.408

Number of Conductors

includes ground

ÖLFLEX® FORTIS is named after the Latin word meaning “strength”. It offers outstanding mechanical performance, particularly at low temperatures. The specially formulated elastomeric jacket passes UL’s -40°C cold impact and -55°C cold bend test. ÖLFLEX® FORTISalso offers outstanding oil resistance (UL OIL RES I & II) and meets all Tray Cable (UL-1277) and Wind Turbine Tray Cable (UL-2277)requirements.

RECOMMENDED APPLICATIONS:Wind energy, Machine tool, Forestry equipment, Oil & petrochem equipment,Cold temperature storage & packaging facilities

APPLICATION ADVANTAGES:• Arctic grade jacket passes UL’s -40°C cold impact test• Passes UL OIL RES I & II requirements• Meets all Tray Cable (UL-1277) requirements• Outstanding mechanical toughness: TC-ER Rated• Meets all Wind Turbine Tray Cable (UL-2277) requirements• Meets Torsion Requirements for Wind Turbine Applications• Copper core is dual rated for North American and European standards 18 AWG (1.0mm2) to 6 AWG (16mm2)

ÖLFLEX® FORTIS CONSTRUCTION:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; formulated oil resistant and elastomeric polymer alloy black jacket.

Minimum Bend Radiusfor installation: 5 x cable diameter

Temperature Range: for stationary use: -55oC to +105oC (UL 90oC)for flexible use: -40oC to +105oC (UL 90oC)

Nominal Voltage: 600V - TC 1000V- Wind Turbine Tray Cable (WTTC)

TECHNICAL DATA:Conductor Stranding: Fine wire per Class 5 (18-16 AWG) Fine Wire per Class K (4 - 2 AWG)

Color Code: Black with white numbers plus grn/yel ground

Approvals: UL: - Type TC-ER (Exposed Run), UL WTTC - Type MTW or UL AWM, NFPA 79 2007 - Oil Res I/II - Class 1, Div. 2 per NEC Art. 336, 392, 501 CSA: - c(UL) Type TC and CIC FT4 -40oC - CSA-AWM I/II A/B FT4 -40oC

LAPP KABEL ÖLFLEX® FORTIS P/N 331404- 14 AWG (2.50MM2)/4C (UL)TYPE TC-ER

Page 24: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com24

ÖLFLEX® TRAY II/ II CYFlexible & Oil Resistant Tray Cable with both UL & CSA TC Approval for Industrial Applications

Color Code: Black with white numbers plus green/yellow ground

Approvals: UL: - Type TC-ER (Exposed Run) or DP-1- UL AWM, Oil Res I & II, Wet Rating 75oC UL

83- UL MTW, NFPA 79 2007- UL -40oC Cold Bend- UL -25oC Cold Impact- UL WTTC (Wind Turbine Tray Cable)1000V Per UL 2277

- Class 1, Div. 2 per NEC Art. 336, 392, 501- Submersible Pump Cable(14 AWG & Larger: 2 to 7 conductors)

- c(UL) Type TC and CIC FT4 CSA: - CSA-AWM I/II A/B FT4Additional: - MSHA-P-07-KA050016-MSHA

(Shielded Only)- Torsion Tested for Wind Market (+/- 90°/m) & (+/- 150°/m)

TECHNICAL DATA:

ÖLFLEX® TRAY II is an industrial grade tray cable with superior oil performance forlong cable life. It has been improved to meet UL Oil Res. I & II and have better coldtemperature flexibility, meeting UL -25ºC cold impact. It has a pressure extrudedjacket and fine copper stranding for excellent flexibility making it much easier topull through tray. With UL TC-ER approval, no conduit is needed so you can reducematerial costs along with saving on labor.

RECOMMENDED APPLICATIONS:Industrial plant expansions, automotive plants, cold temperature processes, traywiring, anywhere that VNTC® cables are used

APPLICATION ADVANTAGE:• Oil resistant pressure extruded PVC jacket for

improved flexibility• Easier to pull than standard tray cables minimizing labor costs

• UL TC-ER approval to reduce material costs. No conduit is needed.

• Black numbered conductors for easy identification

• UV resistant and direct burial• Improved cold temperature flexibility and abrasion resistance

ÖLFLEX® TRAY II CY Construction:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; 100% shielding with foil tape and tinned copperbraid (70% coverage); specially formulated oil resistant black PVC jacket

ÖLFLEX® TRAY II Construction:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; specially formulated oil resistant black PVCjacket.

Please note that VNTC® is a trademark for General Cable Technologies Corporation.

Minimum Bending Radiusfor installation:< 1 AWG: 5 x cable diameter> 1 AWG: 7.5 x cable diameter

Temperature Range: -40oC to +90oC UL/CSA TC-40oC to +90oC UL/CSA/AWM

Nominal Voltage: 600V - TC1000V - AWM1000V - Wind Turbine

Tray Cable (WTTC)

Conductor Stranding: Class 5 Fine Wire 18 - 6 AWGClass K Fine Wire 4, 2 AWG

LAPP KABEL ÖLFLEX® TRAY II CY - (UL) TC-ER/CSA TC/CIC/CE/RoHS

LAPP KABEL ÖLFLEX® TRAY II CY - (UL) TC-ER/CSA TC/CIC/CE/RoHS

Page 25: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 25

ÖLFLEX® TRAY II/ II CYFlexible & Oil Resistant Tray Cable with both UL & CSA TC Approval for Industrial Applications

18 AWG (19/30) 1.00 mm2

221803 221804 221805 221807 221809 221812 221818 221825 22185016 AWG (28/30) 1.50 mm2

221603 221604 221605 221607 221608 221609 221612 221616 221618 221625 221641 221650 221661 14 AWG (46/30) 2.50 mm2

221403 221404 221405 221407 221409 221412 221418 22142512 AWG (56/.0117) 4 mm2 221203 221204 221205

PartNumber

Number ofConductors

includes ground

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

3457912182550

34578912161825415061

34579121825

345

192531445675113156313

273645647382

109145163227372454553

456075

105135179269374

75100125

Nominal OuterDiameter

inches mm

PartNumber

Number ofConductors

includes ground

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

Nominal OuterDiameter

inches mm

7.58.18.89.5

10.912.114.916.923.9

8.38.99.7

10.511.312.114.415.816.618.825.026.627.6

9.210.010.811.814.516.218.722.5

10.711.712.8

576677

100112171245322646

698398127136171220271289397625760769

87107128169225308439587

111152187

8598115149167255365479961

10312414618920325532840343159293111321148

130159191252335459654874

165226279

ÖLFLEX® TRAY II: Flexible and Oil Resistant Tray Cable

.297

.320

.346.373.429.477.587.664.939

.325.351.381.412.444.476.565.621.652.741.986

1.0481.085

.362

.392

.427

.463.571.636.737.886

.423

.460

.503

22120710 AWG (82/.0117) 6 mm2 221004 221005 2210078 AWG (74/.0159) 10 mm2

220804 2208056 AWG (119/.0159) 16 mm2

220603 220604 2206054 AWG (413/30) 25 mm2

220403 2204042 AWG (665/30) 35 mm2

220203 2202041 AWG (836/30) 42.3 mm2

2201041/0 AWG (1045/30) 52.9 mm2

2211042/0 AWG (1330/30) 67.3 mm2

2222043/0 AWG (1672/30) 84.8 mm2

2233044/0 AWG (2107/30) 106.7 mm2

224404250 KCMIL (33 x 19/24) 128.4 mm2

222504350 KCMIL (24 x 37/24) 181.9 mm2

223504500 KCMIL (34 x 37/24) 257.6 mm2

225004

7

457

45

345

34

34

4

4

4

4

4

4

4

4

176

147184257

245306

295393491

406541

640853

1096

1344

1777

2255

2839

3314

4687

6615

14.8

14.716.017.4

17.919.6

19.722.824.9

25.327.8

29.332.3

35.6

37.2

42.5

43.1

52.3

55.0

63.5

73.7

258

265317443

412518

462580725

918952

11691394

1978

2195

2750

3717

4694

5102

5578

7090

384

394472661

615771

688864

1080

13671418

17412077

2947

3271

4098

5538

6994

7602

8311

10564

.581

.578

.631.686

.703

.772

.776.899.982

.9991.094

1.1551.272

1.400

1.466

1.674

1.695

2.059

2.167

2.501

2.902

18 AWG (19/30) 1.00 mm2

2218030 2218040 2218050 2218070 2218120 2218180 2218250 16 AWG (28/30) 1.5 mm2

2216030 2216040 2216050 2216070 2216120 2216180 2216250 14 AWG (46/30) 2.5 mm2

2214030 2214040 2214050

PartNumber

Number ofConductors

includes ground

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

3457121825

3457121825

345

2135425696

138190

38485982

134196261

577893

Nominal OuterDiameter

inches mm

PartNumber

Number ofConductors

includes ground

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

Nominal OuterDiameter

inches mm

8.28.89.410.112.915.717.7

8.99.6

10.311.315.117.319.6

9.810.711.6

8092

100130222294386

97116127165286346476

121150180

119137149193330438574

144173189246426515708

180223268

ÖLFLEX® TRAY II CY: Shielded Flexible and Oil Resistant Tray Cable

.322

.346.371.398.508.618.695

.350.376.406.443.596.683.772

.387

.423

.458

2214070 2214120 2214180 2214250 12 AWG (56/.0117) 4 mm2

2212040 2212050 2212070 10 AWG (82/.0117) 6 mm2 2210040 2210050 2210070 8 AWG (74/.0159) 10 mm2

2208040 6 AWG (119/.0159) 16 mm2

2206040 4 AWG (413/30) 25 mm2

2204040 2 AWG (665/30) 35 mm2

2202040

7121825

457

457

4

4

4

4

125208303426

121151201

173211291

279

435

613

945

12.516.919.523.3

12.514.415.5

15.516.818.2

18.7

23.3

28.6

33.2

220400527704

212261335

371412575

576

812

1332

1951

327595784

1048

315388499

552613856

857

1208

1982

2903

.494

.667

.768

.917

.491.568.612

.609

.662.717

.737

.918

1.127

1.309

The zero at the end of the part number denotes foil and braid shielding.

Page 26: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com26

ÖLFLEX® TC 600-(UL)TYPE TC-ER 90°C 600V---CSA CIC/TC AWM FT4 RoHS

ÖLFLEX® TC 600 S-(UL)TYPE TC-ER 90°C 600V---CSA CIC/TC AWM FT4 RoHS

ÖLFLEX® TC 600/ 600 S For Exposed Run, no conduit is needed

Additional color code for the conductors and jacket available upon request. Minimums may apply.

Minimum Bending Radiusfor installation: 6 x cable diameterfor shielded: 8 x cable diameter

Temperature Range: -40oC to +90oC UL AWM

Nominal Voltage: 600V - TC1000V - TC Wind Turbine (WTTC)

Test Voltage: 2000V

Color Code: Conductors are black printed with white numbers and color name per color chart ICEA-NEMA (K-2) plus green/yellow ground

Approvals: UL: - Type TC-ER (Exposed Run)- UL AWM, UL Wet Rating 75°C- UL Type MTW, NFPA 79 2007(14 AWG and larger)

- Class 1, Div. 2 per NEC Art. 336, 392, 501

- Bus Drop- 14 AWG & Larger; 3c & 4c only

CSA: - c(UL) CIC/TC FT4- CSA-AWM I/II A/B FT4

TECHNICAL DATA:

ÖLFLEX® TC 600 is a multi-conductor cable approved for use in cable trays. It is ULTC-ER & CSA CIC/TC approved making it perfect for new plant installations and factory expansion. ÖLFLEX® TC 600 S has an overall foil tape and drain wire for EMI& RFI protection.

RECOMMENDED APPLICATIONS:Plant expansion, Contractor market, A & E firm plant designs, Tray wiring, Anywherethat VNTC® cables are used

APPLICATION ADVANTAGE:• Easier to pull than standard tray cables, minimizing labor costs

• UL TC-ER approval to reduce material costs. No conduit is needed.

• Black numbered conductors with printed color code for easy identification

• UV resistant and direct burial• UL wet rating 75oC

ÖLFLEX® TC 600 S Construction:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; 100% shielding with foil tape and drain wire; specially formulated PVC jacket.

ÖLFLEX® TC 600 Construction:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; specially formulated PVC jacket.

Page 27: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com 27

ÖLFLEX® TC 600/ 600 SFor Exposed Run, no conduit is needed.

18 AWG (7 strand) 1.00 mm2

211802 211803 211804 211805 211807 211809 211810 211812 211815 211819 21182516 AWG (7 strand) 1.32 mm2

211602 211603 211604 211605 211606 211607 211609 211610 211612 211615 211616 211618 211619 211620 211625 21163714 AWG (19 strand) 2.08 mm2

211402 211403** 211404** 211405

PartNumber

Number ofConductors

includes ground

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

2345791012151925

2345679101215161819202537

2345

131621273748536480101133

1825344251597685101127135153161169211300

30405467

Nominal OuterDiameter

inches mm

PartNumber

Number ofConductors

includes ground

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

Nominal OuterDiameter

inches mm

6.97.37.98.59.2

10.611.411.713.014.516.6

7.57.98.69.3

10.010.011.612.512.915.115.115.915.916.618.220.9

8.38.79.5

10.3

4255647597

109115166207263312

52678095

123123166184213235246272286301312514

6584

104124

638295112144162171247308391464

77100119141183183247273317350366405426448464765

96125155185

ÖLFLEX® TC 600: Flexible Tray Cable

.273

.287.310.335.361.416.449.462.511.569.648

.295.311.337.364.394.394.455.493.508.594.594.624.624.655.718.822

.325

.343.373.405

8194121135162215256337

506486107128150192257342406428535

74102136170238306408646

245

393

11.211.213.014.915.316.917.820.5

9.29.8

10.611.612.612.615.517.319.220.221.224.4

11.211.913.015.016.319.021.326.0

16.5

18.9

164164218242298373450569

85111148181250324360432540684720900

1481932573074305497371178

597

838

244244324360443555670847

127165220269372482536643804101810711339

220287382457640817

10971753

888

1297

.439

.439.510.585.602.665.699.807

.363

.384.419.456.496.496.610.681.754.794.835.960

.439

.466.511.591.642.748.8391.024

.650

.746

ÖLFLEX® TC 600 S: Shielded Flexible Tray Cable

6791012161925

23456791216192025

2345791219

4

4

18 AWG (7 strand) 1.00 mm2

211802S 211803S 211804S 211805S 211807S 211809S 211810S 211812S 211815S 211819S 211825S16 AWG (7 strand) 1.32 mm2

211602S 211603S 211604S 211605S 211606S 211607S 211609S 211610S 211612S 211616S 211619S 211620S 211625S14 AWG (19 strand) 2.08 mm2

211402S 211403S** 211404S** 211405S

PartNumber

Number ofConductors

includes ground

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

2345791012151925

2345679101216192025

2345

131621273748536480101133

1825344251597685101135161169211

30405467

Nominal OuterDiameter

inches mm

PartNumber

Number ofConductors

includes ground

CopperWeightlbs/mft

Approx.Weight

lbs/mft kg/km

Nominal OuterDiameter

inches mm

7.07.37.98.59.2

10.611.411.713.014.516.6

7.67.98.69.3

10.010.011.612.612.915.115.916.618.2

8.38.79.5

10.3

44576677

100112118171213271321

54698298127127171190219253295310321

6787

107128

658498115148167176254317403478

80103123145188188254281327377439461478

100129160191

.276.290.313.338.364.419.452.465.514.572.651

.298.314.340.367.397.397.458.496.511.597.627.658.721

.328

.346.376.408

211406S 211407S 211409S 211410S 211412S 211416S 211419S 211425S12 AWG (19 strand) 3.30 mm2 211202S 211203S** 211204S** 211205S 211206S 211207S 211209S 211212S 211216S 211219S 211220S 211225S10 AWG (19 strand) 5.32 mm2 211002S 211003S** 211004S** 211005S 211007S 211009S 211012S 211019S

6791012161925

23456791216192025

2345791219

8194121135162215256337

506486107128150192257342406428535

74102136170238306408646

11.211.213.014.915.316.917.820.5

9.39.8

10.611.612.612.615.517.319.220.221.424.4

11.211.913.015.016.319.021.326.0

169169225249307384464586

89114152186258334371445556705742927

1541992653164435657591213

251251334371456572690872

132170227277383496552662828

104911031379

22929639347165984211301806

.442

.442.513.588.605.668.702.810

.366

.387

.422

.459

.499

.499.613.684.757.797.883.963

.422

.469.514.594.645.751.842

1.027

211406 211407 211409 211410 211412 211416 211419 21142512 AWG (19 strand) 3.30 mm2 211202 211203** 211204** 211205 211206 211207 211209 211212 211216 211219 211220 21122510 AWG (19 strand) 5.32 mm2 211002 211003** 211004** 211005 211007 211009 211012 2110198 AWG (19 strand) 8.38 mm2

2108046 AWG (19 strand) 13.2 mm2

210604

Page 28: THE WORLD OF LAPP - Wire & Cable · PDF filefor your individual project if you place importance on ... tinned coated copper and fine stranding provide ... tinned copper conductors,

ÖLFLEX®

P ower & Control Cables

SKINTOP®

Cable Glands

SILVYN®

Conduit

ETHERLINE®

Industrial Ethernet

EPIC®

Connectors

UNITRONIC®

Data Cables

FLEXIMARK®

Marking Systems

HITRONIC®

Fiber Optic Cables

Lapp Canada3505 Laird Road, Unit 10Mississauga, Ontario L5L 5Y7

877-799-5277www.lappcanada.com

Lapp MexicoMetalurgia 2730Alamo Industrial, C.P. 44490Tlaquepaque, Jalisco

800-024-5277www.lappmexico.com

Lapp USA29 Hanover RoadFlorham Park, NJ 07932

800-774-3539www.lappusa.com

The products and specifications set forth in this brochure are subject to change with out notice and Lapp Group disclaims any and all liability for such variations. Lapp Group further disclaims any and all liability for typographical, printing or production errors or changes affecting the products and/or the specifications. Nov 2011 NASolCat Rev. 2