The UTE Speed-O-Calibration Unit (SOC) is used to calibrate the locomotive speedometer. This presentation is an operations outline for Ultra-Tech model 16470-00.

Upload: olinda

Post on 19-Jan-2016

43 views

Category:

Documents


0 download

DESCRIPTION

The UTE Speed-O-Calibration Unit (SOC) is used to calibrate the locomotive speedometer. This presentation is an operations outline for Ultra-Tech model 16470-00. Caution:. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

The UTE Speed-O-Calibration Unit (SOC) is used to calibrate the locomotive speedometer. This presentation is an operations outline for Ultra-Tech model 16470-00.

Page 2: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Caution:

The Operator of this equipment must know and follow general safety procedures concerning electrical and mechanical equipment or be supervised by a qualified trainer.

Page 3: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Setup: Measure and make note of locomotive wheel diameter. The locomotive’s axle alternator is then removed and connected to the Speedometer Calibration Unit (SCU).

Page 4: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Insert and finger-tighten two bolts (as shown).

Page 5: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Open Control Box and confirm that switch is OFF and control is fully counter clockwise.

Page 6: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Attach cable connectors: The connector with the yellow power cable connects to the control box.

Page 7: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

The main case uses the connector without the yellow power cable.

Page 8: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Power is normally supplied by connecting the SCU clips to the locomotive DC supply; a workbench supply can also be used (as shown). Observe proper polarity.

If polarity is reversed, unit will appear to be dead (no power).

Page 9: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Confirm the setup procedure before power up.

- Locomotive axle alternator connected to the SCU.

- Cable connectors correctly attached.

- Power supply properly connected (approx. 72V DC).

- Speed control set to minimum (counter clockwise).

Power Up:

Page 10: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Turn power switch ON and allow the SCU control software to get to the main menu.

Page 11: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Push buttons will light to help show available options.

Page 12: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Follow the displayed instructions.

Select for “WhDia” wheel diameter.

Page 13: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

INCR (increase) or DECR (decrease) the displayed wheel diameter.

Page 14: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Select ENTER when displayed wheel diameter equals measured diameter.

Page 15: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

The top line display should now show the selected wheel diameter and the default target speed.

Page 16: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Operation:

Auto Mode – If auto mode is selected, the speed control must stay at

the home position (completely counter clock-wise).

The target speed can be changed by pushing the INCR or DECR buttons.The SCU will automatically adjust the axle alternator to the targeted test speed.

Manual Mode – If manual mode is selected, the speed control is manually adjusted until the top line speed is nearly equal to the bottom line speed (target speed).

Speedometer calibration is usually done in AUTO mode.

Page 17: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

In either mode:

- The axle alternator speed is adjusted to match the target speed (manually or automatically).

- The target speed can be changed by pushing the INCR or DECR buttons.

- Speed is measured in MPH.- The axle alternator speed will flash when it is

more than 1 mph different than the target speed.

Note: The axle alternator speed must be adjustable to be within FRA tolerances!

+/- 3 MPH for 20 & 22 MPH +/- 5 MPH for 40, 60, 72 & 75 MPH.

Page 18: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Auto Mode Operation:

After following the setup and power up procedures, select auto mode.

The back button can be used to get back to previous menus.

Page 19: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Confirm speed control is at minimum (counter clock-wise). Push “Done” button to continue.

Page 20: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Increase or decrease target speed.

Encoder speed adjustments are to be within tolerance at each target speed.

Target speed is on the bottom line of the display.

Page 21: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Power Down:

Minimize speed control and turn OFF power switch.

Page 22: The UTE Speed-O-Calibration Unit (SOC) is used to      calibrate the locomotive speedometer

Conclusion:

This is the end of this presentation.

If you want more information, please see the Instruction and Operations manual 16470-99.