Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA UNCLASSIFIED Fuel Quality Assurance R&D and Impurity Testing in Support of Codes & Standards June 6, 2017 Team: E. Brosha, R. Lujan, T. Rockward (Presenter) , C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise restricted information” Project ID # SCS007 The U.S. Department of Energy 2017 Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting

Upload: others

Post on 12-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Fuel Quality Assurance R&D and Impurity Testing in Support of Codes & Standards

June 6, 2017

Team:E. Brosha, R. Lujan, T. Rockward (Presenter) ,

C. Romero, S. Williams, M. Wilson , R. Mukundan

“This presentation does not contain any proprietary, confidential, or otherwise restricted information”

Project ID # SCS007

The U.S. Department of Energy 2017 Hydrogen and Fuel Cells Program and Vehicle Technologies Office

Annual Merit Review and Peer Evaluation Meeting

Page 2: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Project start date: 10/1/06 Project end date: 9/30/17** Project continuation and direction

determined annually by DOE

Barriers addressed– G. Insufficient Technical Data to

Revise Standards– K. No Consistent Codification Plan

and Process for Synchronization of R&D and Code Development

• Total project funding: $4775K• Funding received in

FY16: $700K• Total funding planned for

FY17 $750K

Timeline

Budget

Barriers

• Japanese Automotive Research Institute

• SAE• CEA-Liten France• VTT- Helsinki, Finland• ISO TC197/WG 27 & 28

Partners/Collaborators

Overview

Page 3: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Outline• Fuel Quality Analyzer

• Relevance/Impact• Progress in FY17

• Hydrogen Fuel Quality• Background• Motivation• Experimental Set-Up• Results with CO and H2S

• Fuel: Single-pass mode vs. Re-circulation mode

• Pre-Dosing

• Summary• Future Plans

Page 4: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

The development of a device to measure impurities in the fuel stream would be useful to the fuel cell community, hydrogen fueling stations and suppliers. Some of the more important qualities of the device:

Inexpensive

sensitive to the same impurities that would poison a fuel cell stack (e.g. CO, H2S, and NH3)

quick response time to fuel contaminants

Fuel Quality Analyzer: Relevance/Impact

Such a device could be used as an early alert monitor and prevent damage to fuel cell stacks!!!

Page 5: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

This device operates as an electrochemical pump using a MEA-type Configuration. (no air or water available). Measure pumping current before, during and after contaminant exposure.

Use similar components to a fuel cell stack (e.g. Ionomer, PGM, and GDLs)

Reduce overall Pt loading and utilize low surface area catalyst

Identify best materials and their configuration

Approach

5

Page 6: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Membrane Hydration Challenging: Identifying conditions needed for constant membrane humidification Characterize and confirm by

measuring HFR and CV Vary flow conditions Vary Membrane thickness

Determine a fuel flow-rate that will not compromise sensitivity or response time

Inlet

Outlet

Electrode A Electrode B

Teflon holder

Teflon body

Developing the Prototype FY16Approach

Page 7: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Increase in membrane conductivity during flow of dry gas evident and more pronounced in N212 (FY16)

Thicker membrane (N117) maintains hydration longer.

N117

Re-designed hydration scheme with GDLs: 100 cycles are shown overlapping (constant HFR)

Membrane Hydration Tests: Achieved Stability (FY 16)

Accomplishments

Page 8: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Prototype Developed in FY 16 Incorporate design elements from experiments

into analyzer prototype- standard PEMFC hardware– Better current collection, uniform

compression, etc.– Use as much common hardware as

possible.– Allow for pressurization.

Use LANL membrane humidification approach. Test complete analyzer prototype before applying for Patent.

Test HFR stability and determine maximum dry gas flow rate.

Test analyzer with SAE J2719 contaminant levels

Plan for field testing! Requires precise control of sensor T regardless of changes in ambient T.

-0.00125

-0.0012

-0.00115

-0.0011

-0.00105

-0.001

-0.00095

-0.0009

40 60 80 100 120 140

Analyzer response to 50 ppm CO

Cur

rent

(A)

Time (min)

CO on

Page 9: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

SAE Level Studies: Baseline Measurement

0.039 mg Pt/cm2; Low Pt GDE working electrode (25BC) & Counter: 0.2 mg PtRu/cm2

Baseline conducted at 30oC and ambient pressure for comparison Gases were externally humidified and membrane wicking humidification system employed 0.3V hold , 200 ppb CO and 500 ppb CO exposure shows clear response (current decay) No natural recovery observed

Accomplishments

Page 10: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Membrane/GDL Wicking : Clear Response at SAE Level

Dry gases along with the membrane and GDL wicking humidification system Gas Diffusion Media changed to a less hydrophobic material Initial baseline before CO exposure more stable than previous ‘Baseline’ Response to 200 and 500 ppb CO similar to ‘Baseline; No natural recovery observed

Accomplishments

Improved Baseline

Page 11: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Patent Application Filed for Analyzer Prototype in FY17

An application for US patent was filed November 2016 for a prototype fuel quality analyzer that uses a novel membrane humidification scheme the permits the use of Nafion® membrane in dry environment. Incorporates latest design improvements to double sample gas flow rate while maintaining membrane and electrode HFR.

Docket No. 127686/LANS(S133399), “Hydrogen Fuel Quality Analyzer with Self-Humidifying Electrochemical Cell and Methods of Testing Fuel Quality”

Experimental data provided showing detection of 200ppb CO in dry H2 with equivalent performance to conditions of external humidification of test gases.

Accomplishments

Page 12: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Impact of Ionomer

0

0.002

0.004

0.006

0.008

0.01

0 500 1000 1500 2000 2500

Current Respose to Varying CO Concentrations: 10 min at 0.1 V, Ionomer Impact

Temp: 30oC, Flowrate: 100 sccm, Ambient Pressure

H2 pumping current, 200 ppb COH2 pumping current, 500 ppb COH2 pumping current,1 ppm CO

Cur

rent

(A)

Time (s)

CO off

A6_vh_dryCO_100sccm_overlay

CO on

Accomplishments

Electrode resistance high without ionomer; any water alters electrode resistance significantlyIonomer was added to the working electrode to help stabilize electrode water contentCurrent decay rate and extent increases with CO concentration

Improved humidification!!!

Page 13: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Investigating Clean-Up Strategy

0

5

10

15

0 5 10 15 20 25 30 35

Imp Spectras for Varying CO Concentrations: 10 min at 0.1 V, Ionomer Impact

Temp: 30oC, Flowrate: 100 sccm, Ambient Pressure

dry H2 - Neat200ppb dry CO (10min)0.75V clean (10min) after 200ppb dry CO500ppb dry CO (10min)0.75V clean (10min) after 500ppb dry CO1ppm dry CO (10min)0.75V clean (10min) after 1ppm dry CO

-Zim

ag (o

hm)

Zreal

(ohm)A6_EIS_dryH2_CO_100sccm_pp1

Applied 0.75V as a ‘Clean-Up’ Method Analyzer reset after 200 ppb CO Recovery not complete at higher concentrations

Accomplishments

Page 14: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

0

2

4

6

8

10

12

14

0 5 10 15 20 25 30

Imp Spectras for Varying CO Concentrations: 10 min at 0.1 V with Clean-up Strategy

Temp: 30oC, Flowrate: 100 sccm, Ambient Pressure

dry H2 - Neat50ppm dry CO (10min)0.75V clean (10min) after 50ppm dry CO500ppb dry CO (10min)0.75V clean (10min) after 500ppb dry CO200ppb dry Co (10min)0.75V clean (10min) after 200ppb dry CO

-Zim

ag (o

hm)

Zreal

(ohm)A7_EIS_dryH2_CO_100sccm_pp1

Changed the Ionomer to Catalyst Ratio/Investigating Clean-Up Strategy

0

1

2

3

4

5

0 1 2 3 4 5

-Zim

ag (o

hm)

Zreal

(ohm)A7_EIS_dryH2_CO_100sccm_pp1

200 ppb CO

Responses still observed to 200 ppb CO 0.75 V applied after CO exposures Clean-up shown at 5 times SAE level!!! Reduce Ionomer by a factor of 10

Similar responses to CO observed

Accomplishments

Page 15: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Current fuel specifications: ISO 14687-2 and SAE J2719 allow 200ppb CO, 4ppb H2S, others

Previous FC studies were instrumental in their development; higher loaded Pt electrodes (≥ 0.4 mgPt/cm2) were used, tests were conducted in single-pass at constant current densities

U.S. DOE 2020 target loading calls for 0.125 mgPt/cm2 which results in an anode loading approaching 0.025 mgPt/cm2

Focus: Low loaded electrodes tested in both single pass mode and fuel re-circulation mode at impurity levels in the fuel specification

Hydrogen Fuel Quality: Background

Provide useful data to OEMs/ Modelers and FC Community; particularly modelers for predicting the impact under broader operating conditions

Understand the impact of impurities with more realistic test conditions

The question remains: Do the standards need revision? If so, Relaxed or Tightened

Motivation

Page 16: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Fuel Re-Circulation System: Single-Pass Mode

Humidity Bottle Anode

Hyd

roge

n

CO

/H2

CathodeMKS FC

Vent

T, RH, P

Pressure Regulator

H2S

/H2

P

P

P

P

Typical fuel cell operation:

Testing conditions are controlled: T, RH, P, and gas flows Contaminants introduced at the anode inlet

(by-pass humidifier) Automated data acquisition (LabVIEW)

MEA: 25 cm2, A/C: 0.05/0.10 mg Pt/cm2

NR211

Fuel stream exhaust gets released to atmosphere.

Page 17: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Fuel Re-Circulation System for Fuel Quality Testing

Humidity Bottle

Condenser/

Water Trap

AnodeH

ydro

gen

CO

/H2

CathodeMKS FC

Automatic H20Drain

Reservoir

SVHeater

T, R

H

CheckValve

Vent

Hea

ter

[H2]

Pressure Regulator

Pump

H2S

/H2

P

[H2]

T, RH

P

P

Hydrogen fuel enters the anode feed dry and gets humidified via in-situ cross-over cathode water It is critical to remove liquid water from the system! H20 is condensed and released automatically The return fuel is monitored: H2 concentration, relative humidity, and temperature Purging can be activated via: [H2] %, cell voltage limits, or timed duty cycles The pump speed is controlled along with the return gas relative humidity via the local temperature

Prevents liquid H20 from beingre-circulated.

solenoid valve allows purging

Page 18: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

T: 80 oC Tolerance of [CO] in PEM Fuel Cells

Pressure (kPa) 80 150 275 80 150 275 80 150 275

[CO] (ppm) 1 1 1 0.5 0.5 0.5 0.2 0.2 0.2

RH (%)

32 0 0 0 0 0 050 51 mV 42 mV 25 mV 9 mV 2 mV 0100 51 mV 51 mV 29 mV 10 mV 13 mV 0

completed

Is there a need to revise standards?– Evaluate tolerance on MEAs with low anode loadings

(0.05mgpt/cm2)– Compare re-circulation vs single pass– Effect of RH and pressure and concentration

Presented two talks at ECS (10/2016) Create database to provide to modelers

Approach: Parametric Study of CO Tolerance

Page 19: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Anode: 0.2 mg cm-2 Pt/C, 209 sccm H2,Cathode: 0.2 mg cm-2 Pt/C, 833 sccm Air, Membrane: Nafion® 211; Cell: 80ºC @ 1A/cm2

The anode was exposed to 1.0 ppm, 0.5ppm and 0.2 ppm CO for 7, 14, and 35h

CO Effects: Constant Dosage (Higher loading)

Cell voltage was recorded while cell operated at 1 A/cm2 under ambient and 74.5 kPa (10.8 Psig) back pressure.

XRF Loading showed higher Pt loadings than DOE target

Accomplishments

Page 20: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Voltage loss versus CO concentration was plotted for both pressures 74.5 kPa tolerated 0.2 ppm CO (35hrs) and Ambient pressure showed a 13mV decay @ 100% RH (Left graph)

Constant dosage expt’s were repeated at 50% RH both pressures were able to tolerate 0.2 ppm CO within the accuracy of the load box (Right)

CO Effects: Constant Dosage/RH ImpactsAccomplishments

Page 21: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 20 40 60 80 100 120 140 160

4ppb H2S Testing

100% RH 80oC 10.8psigCO added at 50.232hrs | Voltage Loss: ~18.884mV

MEA Total Loading: .143mg/cm 2

Cel

l Vol

tage

(V)

Time (Hrs)0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 20 40 60 80 100 120 140 160

0.2ppm CO Testing

100% RH 80oC 10.8psigCO added at 88.668hrs | Voltage Loss: ~30mV

MEA Total Loading: .143mg/cm 2

Time (Hrs)

Cel

l Vol

tage

(V)

CO, H2S Effects (Lower loading)

Voltage drops 13mV after 35 hrs of exposure to CO, whereas the higher Pt loading MEA was tolerant. 30mV losses observed after 100 hrs of exposure. (left graph)

Natural voltage decay observed during H2S poisoning: Losses computed by the difference in decay rates before and during exposure (right graph)

H2H2 + CO H2 H2 + H2S

Accomplishments

Page 22: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Pre-Dosing Experiments

What happens if there is an unlikely event that releases S?

Our international collaborator, CEA (France), is also engaged

in these studies. (HyCoRA)

25cm2, Low Loading MEAs

Data collected at CEA facility with LANL hardware and

components

Subsequent exposures to CO and H2S shows both regions are impacted

H2S regions are decreasing with successive exposures

CO impacts become more severe as S coverage increases

LANL/CEA Single-Pass Results

Page 23: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Pre-Dosing Experiments:200ppb CO in Hydrogen

H2S for 5 minutes In re-circ mode, we introduce 4ppb H2S

for 5 minutes

No voltage loss during S exposure

200ppb CO is introduced for 7h

Voltage losses with CO ~10mV

Similar scenario except with 10 ppbH2S pre-dose

Losses are enhanced as concentration of pre-dose gas increases. 2X the losses

A system upset containing sulfur can be detrimental to cell performance. At theSAE/ISO levels the CO impacts become more severe.

1.2 ppm H2S for 1 second should have the same effect (dosage controlled)

Accomplishments

Page 24: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

• Fuel Quality Analyzer: FY17 Improvements One order of magnitude improvement in baseline Dramatic improvement in CO sensitivity (sensitive to

< 50 ppb) Operation under dry H2 for > 1 month

Successful prototype developed (Patent applied for)• Hydrogen Fuel Quality: Determined that low loaded MEAs are not tolerant to

SAE J2719 level of impurities Parametric study of impurities underway to quantify CO

and H2S tolerance levels of low loaded MEAs Testing under dynamic conditions including impurity

mitigation strategies will ultimately determine the future of fuel quality standards (relax or tighten?).

Summary

Page 25: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Modify the Re-Circulation System to include Gas Chromatography for mass balance experiments

Incorporate Start-Stop capabilities to mimic vehicle behavior and investigate it as a recovery strategy

Test with the entire fuel cell specification (minus particulates) and apply start-stop protocol

Test using an accepted Drive Cycle

Future Plans Repeat results CO dosage experiments: Can we quantify contaminants? Add inline gas filters to clean H2 Employ Research Grade H2 (99.9999%) Investigating Field Deployable Electronics Test other impurities: H2S, NH3 Test new flow-field configuration for improved sensitivity and

response time Demonstrate analyzer in the field after independent evaluation

Anal

yzer

Fuel

Qua

lity

******************************************************************************

Page 26: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Acknowledgements

DOE- Will James, SCS Manager Jari Ihonen, VTT Jay Keller CEA (Grenoble, France) SAE

And you the Audience!!!!!

Page 27: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Additional Slides

Page 28: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

0

0.005

0.01

0.015

0.02

0.025

0.03

0.035

0 500 1000 1500 2000 2500 3000

Current Respose to Varying CO Concentrations: 10 min at 0.1 V

Temp: 30oC, Flowrate: 100 sccm, Ambient Pressure

H2 pumping current , 50ppm COH2 pumping current, 500ppb COH2 pumping current, 200ppb CO

Cur

rent

(A)

Time (s)

CO on

CO off

Optimizing the Ionomer to Catalyst Ratio

Reduce Ionomer by a factor of 10 Response is almost instant!!! Activation step are being explored

Accomplishments

Page 29: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

Fuel Re-Circulation System: Future Work

Humidity Bottle

Condenser/

Water Trap

Anode

Hyd

roge

n

CO

/H2

CathodeMKS FC

Automatic H20Drain

Reservoir

SV

Dryer

HeaterT,

RH

CheckValve

Manual Valve

Vent

Hea

ter

[H2]

Pressure Regulator

Pump

H2S

/H2

P

[H2]

T, RH

GC

P

PAi

r

Start/ StopP

Incorporate Drive cycles and Start/Stop protocols.

Analysis

Page 30: The U.S. Department of Energy 2017 Hydrogen and Fuel ......C. Romero, S. Williams, M. Wilson , R. Mukundan “This presentation does not contain any proprietary, confidential, or otherwise

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA

UNCLASSIFIED

“Project strengths are the project’s strong knowledge, experimental base, and international partnership.“

Continuing and strengthening international collaborations and creating extensive data base that will guide future standards.

“Development of an in-line analyzer for hydrogen fuel quality will facilitate deployment of FCEVs and hydrogen refueling dispensers.”

Project specifically looking into that. Plans to do field testing after developing electronics

Reviewers Comments

“Project weaknesses are the lack of time scale for publication of ASTM standards”

“The weakness of the project is the under-appreciation of the noise factors that could change the gas analyzer signal”

Accelerated development of analyzer. Significant progress made in designing and building prototype analyzer. Developed IP.

Resources diverted from ASTM work to Analyzer work.