William H. Swain founded the company in 1965
• Bill Swain founded the William H. Swain Co. in Sarasota Florida back in 1965. Previous to this Bill was employed in various roles with the US military and NASA – working on guidance systems for rocket and advanced marine navigation tech for that time period.
Bill Pictured second from left
![Page 4: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/4.jpg)
Development of the SWAIN METER
In 1965 Bill Swain developed the first DC Clamp-on Ammeters. These durable and accurate instruments were created to help pipe line operators monitor cathodic protection (CP) current flow on their lines.Used in a wide variety of industries all over the world, Swain meters measure the magnitude and direction of current on conductors. From the beginning Swain meterswere used not only as portable DC and AC current measuring devices, but as permanently installed instruments on buried pipelines both on-shore and in sub-sea applications.The uniqueness of the Swain Meter is the same today as it was 43 years ago when Bill built his first meter. This DC Clamp –on ammeter is Still the only one of its kind in the world today.
Pictured below are some of Swain’s first analog ammeters.
![Page 5: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/5.jpg)
The next 40 years
• In the mid 1980’s Swain meters were fitted with digital LCDs. The technology remains basically the same while the meter face becomes more streamlined and user-friendly.
![Page 6: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/6.jpg)
Swain Meter evolves
Later models of Swain meters in the 90’s and 2000’s still use the bullet-proof and patented technology. These later models have digital LCD’s and further simplified controls.
Swain meters are manufactured in 2 models – The MER Meter (pictured left) has a “manual” Zeroing knob and Range select switch.
![Page 7: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/7.jpg)
Swain Meter evolvesThe second meter we call the “AUTO MER”. This features Auto- Zeroing and AutomaticRanging from 0 – 2.0 Amps, 0 – 20 Amps &0 – 200 Amp ranges.
Both MER and AUTO MERMeters have data output Jacks.
![Page 8: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/8.jpg)
The technology that drives the Swain Meter has changed little in over 40 years. Yet the switch from Analog to Digital technology has greatly increased
the efficiency of the manufacturing and calibration processes.
Old School New School
![Page 9: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/9.jpg)
Swain Clips & Clamps
• Swain Clips & Clamps are precise and sensitive instruments that form a 360` closed loop around a conductor.
• Swain Clips and Clamps are also referred to in literature as “Sensors” connect to the MER meter.
• Swain Sensors are rugged, hand crafted instruments that work in harsh environments
![Page 10: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/10.jpg)
Clips & Clamps come in many sizesClips are hand held, spring loaded sensors for quick readings on conductors.
Clips are built from 3/4” in diameter through 6” in diameter.
Clips shown to the right are sizes: Mini-Clip (no longer built), 3/4”, 1.5”, 2.5”, 4” &6”.
![Page 11: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/11.jpg)
Swain Clips & Clamps
Clamps are sensors made in 2-half circles that go around Conductors then held together with Nuts to form a circle.
Clamps are built in diameters beginning at 6” through 82”.
Clamp diameters from 60”on up are built in 4 sections.
![Page 12: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/12.jpg)
Larger Clamps
42” Clamp
Clamp Construction
![Page 13: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/13.jpg)
Larger diameter clamps must be manufactured in 4 pieces. This clamp is being assembled for a field test prior to shipping.
82” MER 2 Clamp Clamp is constructed in 4 Sections
![Page 14: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/14.jpg)
Our largest to date – 82”
This 82” Clamp was sold to Water Care Services in Auckland New Zealand in Summer 07’
Clamps of this size usually require their own AUTO MER meter
![Page 15: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/15.jpg)
80” Clamp sold to San Diego County Water Authority
Long time Swain enthusiast Brendan Sheehan
![Page 16: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/16.jpg)
80” clamp in use in San Diego to test flanges
![Page 17: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/17.jpg)
Brian Horanoff, President of The Swain Meter Co. & wife Deb showing off trophy Salmon taken in Lake Michigan.
![Page 18: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/18.jpg)
What IS a Swain Meter?
• Precision built and calibrated instrument, coupled with clips or clamps, used to measure magnitude and direction of current flow.
• Swain meters are used today in most all countries on the planet.
![Page 19: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/19.jpg)
MER Meter with 4” clipThe MER meter allows the operator to manually adjust the zero and range switch. The AUTO MER does this for the operator
![Page 20: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/20.jpg)
USESCorrosion Control
• CP system circuit diagnostics• Locate shorts• Find foreign line interference• Rectifier output• Anode cables• Telluric Current Studies
![Page 21: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/21.jpg)
USES
POWER GENERATION• Battery float charge and load current• Grounding system current drain• Tower leg interference• Guy wire current drain• Data-logger studies
![Page 22: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/22.jpg)
USES
MARINE• Dock/Platform anode current• Current leakage from propeller• Undersea pipelines/anode cables• ROV capable• Oil rig platform testing• Ship anchor current leakage
![Page 23: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/23.jpg)
USES
AUTOMOTIVE
• Current leakage in electrical systems• Alternator and battery diagnostics• Production plant assembly
![Page 24: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/24.jpg)
USES
Energy Transmission
• Flange leakage• Direct burial for long-term monitoring• Interference testing• Used during direct assessment of pipe
![Page 25: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/25.jpg)
Other Uses
• Copper Electro-winding• Nitric Acid drilling• INS troubleshooting• Dairy farm stray current• DC transit stray current• “Well Head” current measurements• Defense industry • Defense Contractors
![Page 26: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/26.jpg)
Refineries use Swain meters to precisely measure current distribution and to see if insulating flanges are working. Individual cables in rectifiers are measured with accuracy as are banks of pipes and cables in close proximity
![Page 27: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/27.jpg)
Standard Operation of the Swain Meter
![Page 28: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/28.jpg)
Using the MER MeterThe Swain meter is a precise instrument that measures DC current from 5-milliamps to 200 Amps with a + /- 1% accuracy.
The meter measures with a 1-milliAmp resolution in the 0 – 2 Amp Range10-milliAmp resolution in the 0-20Amp Range100-milliAmp resolution in the 0 – 200 Amp Range
The meter will cancel out up to a 10-Amp AC interference - this designed to maintain accuracy with DC measurements
![Page 29: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/29.jpg)
Using the MER Meter•Connect the Clip or Clamp to the Swain Meter•Turn the On/Off Switch to the “ON” position•Turn Range Select to 2A
•Hold the Clip or Clamp 6 inches away from the conductor, oriented so the plane of the clip/clamp intersects the conductor at a right angle
•Hold the Clip/Clamp still
•Adjust Zero knob until LCD reads Zero •*(You have successfully canceled the earth field reading)•Place clip/clamp on conductor and observe reading•If current exceeds 2-Amps and “Over Range” message appears on LCD – Turn Range knob to 20A or the 200A position
![Page 30: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/30.jpg)
Using the MER MeterCurrent direction is indicated by either the presence or the absence of a “Negative” Sign the left of the numbers on the LCD
The current direction Arrow is etched onto the sides of all clips and clamps.
Take a reading with the clip/clamp in one direction then flip-it 180` and notice the appearance of the Negative sign.
*Current direction is always flowing in the positive clip/clamp orientation
![Page 31: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/31.jpg)
Clip on conductor and take reading
![Page 32: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/32.jpg)
Using the AUTO MER
The Swain meter is a precise instrument that measures DC current from 5-milliamps to 200 Amps with a + /- 1% accuracy.
The meter measures with a 1-milliAmp resolution in the 0 – 2 Amp Range10-milliAmp resolution in the 0-20Amp Range100-milliAmp resolution in the 0 – 200 Amp Range
The meter will cancel out up to a 10-Amp AC interference - this designed to maintain accuracy with DC measurements
![Page 33: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/33.jpg)
Using the AutoMER
•Connect the Clip or Clamp to the Swain AutoMER meter•Hold the Clip or Clamp 6 inches away from the conductor, oriented so the plane of the clip/clamp intersects the conductor at a right angle•Hold the Clip/Clamp still •Turn the On/Off Switch to the “AUTO” position. Wait several seconds until the “Ready” light comes on*(You have successfully canceled the earth field reading)•Place clip/clamp on conductor and observe reading•If current exceeds 2-Amps the AutoMer meter automatically changes ranges to the 20A range or 200A range
![Page 34: The Swain Meter Co. A brief history of Swain and Operational Procedures By Scott Miret 10/7/08](https://reader036.vdocuments.us/reader036/viewer/2022062511/5516b116550346a25b8b5a93/html5/thumbnails/34.jpg)
Using the AutoMERin Manual Mode
Turn On/Off Switch to “Manual” Mode
Hold clip/clamp steady near conductor
Zero meter using the “Zero” knob
Place clip/clamp onto conductor and take reading
*To manually change ranges, turn On/OffSwitch from “Manual” to “Off” for a split second. Note the LCD decimal point shifts one position to the right . Repeat to change ranges again.
Example of LCD positions: .000 = 2A Range 0.00 = 20A Range 00.0 = 200A Range