the stealth reader meter interface unallows for 2-way it

2
The Stealth Reader Meter Interface Unit allows for 2-way communication, migration from Drive-by to Fixed Network mode and is meter agnostic. Hybrid 2-way Drive-by and Fixed Mesh Network A Deploy first as drive-by and later upgrade to fixed mesh network using the same meter interfaces/inserts. Two-way 902-928MHz FHSS drive-by delivers maximum range and penetration. True battery fixed mesh network eliminates the need for towers and AC-powered repeaters. Every meter is also a repeater! Fixed mesh network is self-forming and self-healing. Meters automatically discover and join the network. AMR Capabilities Log meter readings hourly or daily Stores up to 1 year of hourly readings Configurable reporting: hourly, 4 hours, daily, etc. Detect/report leak, tamper, low battery Water conservation monitoring and reporting Meter Agnostics Pulse registers Dual-pulse registers Encoded registers using most common protocols ABB, Actaris, AMCO, Badger, Neptune, Sensus Utilities can mix new meters with installed bases

Upload: others

Post on 16-Oct-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Stealth Reader Meter Interface Unallows for 2-way it

The Stealth Reader Meter Interface Unit allows for 2-way communication, migration from Drive-by to Fixed Network mode and is meter agnostic.

Hybrid 2-way Drive-by and Fixed Mesh Network A Deploy first as drive-by and later upgrade to fixed

mesh network using the same meter interfaces/inserts.

Two-way 902-928MHz FHSS drive-by delivers maximum range and penetration.

True battery fixed mesh network eliminates the need for towers and AC-powered repeaters.

Every meter is also a repeater!

Fixed mesh network is self-forming and self-healing.

Meters automatically discover and join the network.

AMR Capabilities Log meter readings hourly or daily

Stores up to 1 year of hourly readings

Configurable reporting: hourly, 4 hours, daily, etc.

Detect/report leak, tamper, low battery

Water conservation monitoring and reporting

Meter Agnostics Pulse registers

Dual-pulse registers

Encoded registers using most common protocols

ABB, Actaris, AMCO, Badger, Neptune, Sensus

Utilities can mix new meters with installed bases

Page 2: The Stealth Reader Meter Interface Unallows for 2-way it
BNance
Stamp
BNance
Text Box
DIMENSIONS - ENVIRONMENTAL Weight: 1 pound Dimensions: 4.85" H x 5.07" W x 1.76" Depth Batteries: 2 single Lithium-Thionyl Chloride Batteries Operating Temperature Range: + 85 degrees C to -40 degrees C All components are sealed against water intrusion 500Mw radio