the standardised carport - voestalpine
TRANSCRIPT
voestalpine Sadef nv
THE STANDARDISED CARPORT
Headquarters
BelgiumBruggesteenweg 2008830 Hooglede-Gits, BelgiumT. +32 51/26 12 11F. +32 51/26 13 [email protected]
Representative offices
The netherlandsW. Witsenplein 42596 BK Den Haag, The NetherlandsT. +31 70/324 28 02F. +32 51/26 16 [email protected]
France2, Bd Albert 1er94130 Nogent-s-Marne, FranceT. +33 1/43 24 60 11F. +33 1/43 24 60 [email protected]
GermanyFrans-Tilgner-Strasse 1050354 Hürth, GermanyT. +49 22/33 20 11 48F. +49 22/33 20 28 [email protected]
www.voestalpine.com/sadef
SADEF SOLAR STRUCTURES
SECTION VIEWS
All dimensions are in mm
A
A
A - A
WN
FlexPark
FlexPark
1:25
Project Start Date:
Subject:
Project Reference:
Drawn by:
Scale:
Client:
Object: Checked by:
G[12] FLEXPARK MULTIPLE EWSO20035500
G[12] A
General drawing
This print and the information contained here on is confidential disclosure. The subject matter of which is property of SADEF N.V. E-Mail: [email protected]
Phone: +32 (0)51 261 211
Internet: www.sadef.be
Telefax: +32 (0)51 261 301
This drawing must be printed on paper size not less than A3
Tekl
a S
truct
ures
~ 1650x1000mm2*15*n solar panels e.g.
3D VIEW - T-frame
12°
3400
min
. 600
ground level
trapezoidal steel sheetingsolar panels on top of
SECTION VIEW - Y-frame
foundationconcrete21
00
5070
1000 483 1000
5070
TOP VIEW
5000
10148
5000
3D VIEW - Y-frame
~ 1650x1000mm2*15*n solar panels e.g.
12°
1000
trapezoidal steel sheetingsolar panels on top of
SECTION VIEW - T-frame
foundationconcrete
5070
ground level
5070
2100
383 1000
3400
ground level
General drawingFLEXPARK MULTIPLE EW
SIDE VIEW - Y-frame
1000
5064
2300
12°
5064
5001000
3600
min
. 600
Ground levelfoundationconcrete
or supported by FastSlide profiletrapezoidal steel sheetingSolar panel on top of
SIDE VIEW - T-frame
2300
12°
min
. 600
5064
400
5064
12501250
Ground level
or supported by FastSlide profiletrapezoidal steel sheetingSolar panel on top of
foundationconcrete
A
A
A - A
WN
FlexPark
FlexPark
1:25
Project Start Date:
Subject:
Project Reference:
Drawn by:
Scale:
Client:
Object: Checked by:
G[12] FLEXPARK MULTIPLE EWSO20035500
G[12] A
General drawing
This print and the information contained here on is confidential disclosure. The subject matter of which is property of SADEF N.V. E-Mail: [email protected]
Phone: +32 (0)51 261 211
Internet: www.sadef.be
Telefax: +32 (0)51 261 301
This drawing must be printed on paper size not less than A3
Tekl
a S
truct
ures
~ 1650x1000mm2*15*n solar panels e.g.
3D VIEW - T-frame
12°
3400
min
. 600
ground level
trapezoidal steel sheetingsolar panels on top of
SECTION VIEW - Y-frame
foundationconcrete21
00
5070
1000 483 1000
5070
TOP VIEW
5000
10148
5000
3D VIEW - Y-frame
~ 1650x1000mm2*15*n solar panels e.g.
12°
1000
trapezoidal steel sheetingsolar panels on top of
SECTION VIEW - T-frame
foundationconcrete
5070
ground level
5070
2100
383 1000
3400
ground level
General drawingFLEXPARK MULTIPLE EW
SOUTH
ALSO POSSIBLE
NORTH
2300
3600
or supported by FastSlide profileSolar panel on top of trapezoidal steel sheeting
5064
12°
Ground level
NORTH
2300
5064
12°
3600
Ground level
or supported by FastSlide profileSolar panel on top of trapezoidal steel sheeting
SOUTH
DESIGN » Double or Multiple Carport » For 2 parking places per bay » Parking place:
» 2,5 x 5 (x2) metres – Double » … x 5 meters – Multiple
» Clearance: 2,3 metres » Tilt: 12°
ROOF SYSTEMS » Steel deck or solar roof » FastSlide (for panel frame heights above 32mm
and projectsize >250KW)
FEATURES » Modular in length (Multiple) » For all type of panels » Landscape or portrait panel arrangement
MATERIAL » Foundation base: hot-dipped galvanized » Profiles: Metallic coated steel (Zn Mg) or Stainless steel » Bolts: hot-dipped galvanized
OPTIONAL » Powder coating
SCOPE OF DELIVERY BY VOESTALPINE SADEF » Frame components and bolts » Assembly instruction
TO BE CARRIED OUT/PROVIDED BY CUSTOMER » Foundations and anchors » Steel deck + Module fixing » Gutter / down comer
BENEFITS » Easily accessible » Quick and easy mounting » Structural design according to Eurocode and its
corresponding national application document
To be used in following regions (terrain cat. II) and for a snow load up to Sk= 1.1 except for France Sk= 0.95 » Belgium: >200m AMSL » France: for wind zones 1, 2 and 3 ( for terrain category II ) and snow zones up to C2 (below 500m) » Netherlands: wind zone 1,2 and 3 » Germany: for wind zones 1 and 2 and snow zone 1,2 and 3 (≤200m AMSL) » UK: entire country (except for Scotland >200m)
OTHER REGIONS OR LOADS* » Contact voestalpine Sadef
TECHNICAL DETAILS APPLICABILITY BY COUNTRY
Disclaimer: All dimensions are in mmDesign to be approved by voestalpine Sadef
All dimensions are in mm
Below information is intended to provide an estimation for preliminary design purposes. A specialized engineer should make final design after further soil investigation. For very weak soil or very fine-grained sands, ask specialized advice.
FOR MIDDLE LOADSFoundation predesign based on: » Moderately good soil » Ø’ - 30° » q = 15 kN/m2 » Concrete C25/30
CORPORATE BRANDING
FOUNDATION LENGTH L(m)
Flexpark type Middle loads
DOUBLE 3,50
MULTIPLE 5,00
DONNEES TECHNIQUES
www.sadef.com
Le contenu de ce document est confidentiel et est la propriété de voeslpine Sadef nv.
Toutes dimensions en mm page 5/6 Version: 6-WN
Pré-dimensionnement des fondations : Les informations ci-dessous donnent un pré-dimensionnement préliminaire. Un ingénieur spécialisé doit dimensionner correctement les fondations après une étude du sol. Pour les sols faibles ou sablonneux, faire appel à un spécialiste. Pour charge moyenne :
Etude des pré-fondations basée sur : Sol relativement correct ϕ' - 30° q = 15 kN/m2 Béton C25/30
Pour charges élevées :
Un ingénieur spécialisé doit dimensionner les fondations en prenant en compte
les descentes de charges fournies par voestalpine Sadef
et une étude du sol.
voestalpine Sadef ,n’est pas responsable pour le développement et l’exécution des fondations. Les données définies dans ce document sont à titre informatif. Une définition des fondations est à faire par un bureau d’études spécialisé.
Longueur de fondation L(m)
FLEXPARK TYPE Charge moyenne
MONO 2,80
DOUBLE 3,50
MULTIPLE 5,00
DONNEES TECHNIQUES
www.sadef.com
Le contenu de ce document est confidentiel et est la propriété de voeslpine Sadef nv.
Toutes dimensions en mm page 5/6 Version: 6-WN
Pré-dimensionnement des fondations : Les informations ci-dessous donnent un pré-dimensionnement préliminaire. Un ingénieur spécialisé doit dimensionner correctement les fondations après une étude du sol. Pour les sols faibles ou sablonneux, faire appel à un spécialiste. Pour charge moyenne :
Etude des pré-fondations basée sur : Sol relativement correct ϕ' - 30° q = 15 kN/m2 Béton C25/30
Pour charges élevées :
Un ingénieur spécialisé doit dimensionner les fondations en prenant en compte
les descentes de charges fournies par voestalpine Sadef
et une étude du sol.
voestalpine Sadef ,n’est pas responsable pour le développement et l’exécution des fondations. Les données définies dans ce document sont à titre informatif. Une définition des fondations est à faire par un bureau d’études spécialisé.
Longueur de fondation L(m)
FLEXPARK TYPE Charge moyenne
MONO 2,80
DOUBLE 3,50
MULTIPLE 5,00
DOUBLE MULPTIPLE