the school district of philadelphia board of …€¦ · markerboards and tackboards shall be...

7
PAGE 1 OF 2 THE SCHOOL DISTRICT OF PHILADELPHIA BOARD OF EDUCATION Office of Capital Programs 440 North Broad Street, Third Floor - Suite 371 Philadelphia, PA 19130-4015 TELEPHONE: (215) 400-4730 Addendum No. 01 Subject: WC Bryant Classroom Modernization Project B-041C, B-042C of 2018/19 Location: WC Bryant School 6001 Cedar Avenue Philadelphia, PA 19143 This Addendum, dated February 28, 2019, shall modify and become part of the Contract Documents for the work of this project. Any items not mentioned herein, or affected by, shall be performed strictly in accordance with the original documents. 1. Revisions to Drawings and Specifications a. Demolition note #11 on D1.1 was revised. Refer to attached drawing. b. Detail 2/D1.1 was added. Refer to attached drawing. c. Plan 2/I4.2 was revised. Refer to attached drawing. d. Detail 3/I4.2 was revised. Refer to attached drawing. e. Toilet Accessory Schedule on I4.2 was modified. Refer to attached drawing. f. Details L/I4.5 and M/I4.5 were modified. Refer to attached drawing. g. Note regarding “Allowances and Unit Prices” has been removed from E2.1 and E2.2. Refer to attached drawings. 2. Questions and Clarifications 1. Question: Will another manufacturer besides Campbell Rhea be accepted? Response: Campbell Rhea is the Basis of Design manufacturer. Manufacturers providing equal products may be submitted for review. 2. Question: Can MBE/WBE requirements be reduced to a combined goal? Response: 15/20% Combined MBE/WBE Goal already included in the Bidding Documents. 3. Question: Please provide a spec for Electrostatic painting. Response: Specification SECTION 105115: ELECTROSTATIC PAINTING already included in the Technical Specifications.

Upload: others

Post on 12-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THE SCHOOL DISTRICT OF PHILADELPHIA BOARD OF …€¦ · Markerboards and tackboards shall be supplied by the SDP and installed by the contractor. The contractor shall coordinate

PAGE 1 OF 2

THE SCHOOL DISTRICT OF PHILADELPHIA

BOARD OF EDUCATION Office of Capital Programs

440 North Broad Street, Third Floor - Suite 371 Philadelphia, PA 19130-4015

TELEPHONE: (215) 400-4730

Addendum No. 01

Subject: WC Bryant Classroom Modernization Project B-041C, B-042C of 2018/19 Location: WC Bryant School

6001 Cedar Avenue Philadelphia, PA 19143 This Addendum, dated February 28, 2019, shall modify and become part of the Contract Documents for the work of this project. Any items not mentioned herein, or affected by, shall be performed strictly in accordance with the original documents.

1. Revisions to Drawings and Specifications

a. Demolition note #11 on D1.1 was revised. Refer to attached drawing.

b. Detail 2/D1.1 was added. Refer to attached drawing.

c. Plan 2/I4.2 was revised. Refer to attached drawing.

d. Detail 3/I4.2 was revised. Refer to attached drawing.

e. Toilet Accessory Schedule on I4.2 was modified. Refer to attached drawing.

f. Details L/I4.5 and M/I4.5 were modified. Refer to attached drawing.

g. Note regarding “Allowances and Unit Prices” has been removed from E2.1 and E2.2. Refer to attached drawings.

2. Questions and Clarifications

1. Question: Will another manufacturer besides Campbell Rhea be accepted?

Response: Campbell Rhea is the Basis of Design manufacturer. Manufacturers providing equal products may be submitted for review.

2. Question: Can MBE/WBE requirements be reduced to a combined goal?

Response: 15/20% Combined MBE/WBE Goal already included in the Bidding Documents.

3. Question: Please provide a spec for Electrostatic painting.

Response: Specification SECTION 105115: ELECTROSTATIC PAINTING already included in the Technical Specifications.

Page 2: THE SCHOOL DISTRICT OF PHILADELPHIA BOARD OF …€¦ · Markerboards and tackboards shall be supplied by the SDP and installed by the contractor. The contractor shall coordinate

PAGE 2 OF 2

4. Question: Spec 101100 Visual Display, 1.2.A, Markerboard and Tackboard infills by GC, plans say

by SDP. Who is responsible for them?

Response: Interactive Panel Boards (IPBs) shall be supplied and installed by others under the direction of the SDP. Provide blocking for IPBs as necessary and as indicated in the drawings. Markerboards and tackboards shall be supplied by the SDP and installed by the contractor. The contractor shall coordinate with other prime contractors and field verify for the boards and advise SDP of any discrepancy or interferences affecting the design intent. Markerboard and tackboard inserts shall be supplied and installed by the contractor.

5. Question: Please confirm all visual display boards supplied by SDP will be delivered to each

location by the SDP. Response: Yes, Owner supplied visual display boards will be delivered to the school.

6. Question: Reference spec. 101100; Owner supplied visual display units, par. 1.3 B .3. Please provide manufacturers installation details. Response: Proceed on the basis that the Owner-supplied visual display units are similar in type to those listed in specification section 10 1100 VISUAL DISPLAY UNITS and install in accordance with the manufacturer’s instructions as described in the specifications.

7. Question: Reference Supplementary Conditions section 16, photographs. Please consider deleting

this section from scope of work as it does not seem appropriate or necessary for these type of projects.

Response: Already deleted by Section 01 1400 MODIFICATIONS TO THE GENERAL AND SUPPLEMENTARY CONDITIONS.

8. Question: Is there an environmental specification for Bryant school? Is there any asbestos removal

for these projects?

Response: See Environmental Coordination already included in the Bidding and Contract Documents for requirements. No Specification for Asbestos Abatement for which GC would be responsible included in the Bidding and Contract Documents.

END OF ADDENDUM NO. 1

Attachment(s) 5 Drawings – D1.1, I4.2, I4.5, E2.1, E2.2

Specification(s) - None

Page 3: THE SCHOOL DISTRICT OF PHILADELPHIA BOARD OF …€¦ · Markerboards and tackboards shall be supplied by the SDP and installed by the contractor. The contractor shall coordinate

PRE-KINDERGARTEN CLASSROOM

113

PRE-KINDERGARTEN CLASSROOM

114 KINDERGARTEN CLASSROOM

101

KINDERGARTEN CLASSROOM

102

KINDERGARTEN CLASSROOM

103

1ST GRADE CLASSROOM

104

1ST GRADE CLASSROOM

105

1ST GRADE CLASSROOM

106

PRE-KINDERGARTEN CLASSROOM

107

PRE-KINDERGARTEN CLASSROOM

108

1 1

1

11

1

1

1

2

2

3

3

1

4

4

4

4

4

4

4

4

66

5

5

5 5

5

5

5

55

5

5

7

7

77

7

7

7

7

8

9

109

9

999

9

9

13

11

11

1 4

5

11

11

1116

16

16

16

1616

1616

1616

16 16

16

16 16

16

16

16

13

16

99

16

17 17

11

11

14

1420

16

20

14

2018

20

1515

111111

15

STORAGE

102C

STORAGE

102D

TOILET

102E

TOILET

101D

STORAGE

101B

TOILET

103A

TOILET

104A

15

11

1 5

6

11

15

14

14

.12

15

15

15

19

10

7

10

9 7 9

1 5

6 7

10 10

1 4

5 7

10

1 4

5 7

10

1 4

5 7 7

1 4

5 7

1 4

5 7

197

9

1 4

5 7

2

3 4

5 197

9

10

1

4 5

7

4

9

2

3 4

5 197

11

1

TR

IM H

EIG

HT

MA

TC

H E

XIS

TIN

G

NEW WOOD TRIM TO MATCH EXISTING ADJACENT TRIM IN HEIGHT AND PROFILE

FINISH FLOOR AS SCHEDULED

WHERE NEW WOOD TRIM OCCURS - TERMINATE EXISTING AT CORNER AND PROVIDE WOOD CORNER BLOCK. FINISH TO MATCH TRIM. CORNER BLOCK TO EXTEND A 1/4" MIN ABOVE TOP OF TRIM.

TRIM PROFILE BEYOND

PATCH AND REPAIR EXISTING WALL

1

LOCATION NO. FILE NO.

DRAWN BY CHECKED BY

DRAWING NO.

1

NO. DATE REVISION

www.philasd.org

SCHOOL & LOCATION

PROJECT TITLE

DRAWING TITLE

87654321

A

B

C

D

E

F

P H I L A D E L P H I A

(215) 400 - 4730 (215) 400 - 4731 (fax)

440 NORTH BROAD STREETPHILADELPHIA, PA 19130 - 4015

OFFICE OF CAPITAL PROGRAMS

T H E S C H O O L D I S T R I C T O F

SEAL:

R. JEFFREY STRAUB

STATE AND LICENSE NO: RA403652

Attn: Jessie Harder

Email: [email protected]

Phone: 717-458-0272

Mechanicsburg, PA 17055

401 E. Winding Hill Road

CRABTREE, ROHRBAUGH & ASSOCIATES

ARCHITECT

Attn: Deepak Ajjimane

Email: [email protected]

Phone: 667-309-6036

Baltimore, MD 21202

One South Street, Suite 1130

SETTY

MEP ENGINEERS

2

3

4

5

6

7

8

9

10

ADDENDUM #12/27/2019

B-041C OF 2018 / 19

B-042C OF 2018 / 19

CRA NO.3223

FIRST FLOOR DEMOLITIONPLAN

01/18/2019

D1.1

W.C. BRYANT SCHOOL

6001 CEDAR AVENUE,

PHILADELPHIA, PA 19143

100% CONSTRUCTION

CLASSROOMMODERNIZATION

1/8" = 1'-0"D1.1

1 OVERALL FIRST FLOOR DEMOLITION PLAN

GENERAL ALTERATION NOTES:

R1. GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND RECORDING OF ALL EXISTING BUILDING DIMENSIONS AND CONDITIONS RELATED TO THE WORK, INCLUDING BUT NOT LIMITED TO FINISHES, MATERIALS AND SYSTEMS SHOWN AND DESIGNATED AS EXISTING IN CONTRACT DOCUMENTS. ANY DISCREPANCIES FROM INFORMATION INDICATED ON CONTRACT DOCUMENTS SHALL BE DIRECTED TO THE ATTENTION OF THE ARCHITECT. VERIFICATION OF CLEARANCES REQUIRED FOR ALL NEW EQUIPMENT, PIPING, DUCTWORK, AND RELATED COMPONENTS SHALL BE THE CONTRACTORS RESPONSIBILITY.

R2. GENERAL CONTRACTORS RESPONSIBILITY TO REVIEW WITH THE OWNERS REPRESENTATIVE, ALL ITEMS REQUIRING REMOVAL BEFORE THE START OF WORK. OWNER RESERVES THE RIGHT TO SALVAGE ANY ITEM. ALL REMAINING ITEMS SHALL BE DISPOSED OF OFF SITE.

R3. WHERE EXISTING WALL OPENINGS ARE INDICATED TO BE CLOSED, USE MATERIALS AND FINISHES TO MATCH ADJACENT EXISTING FINISHES. MASONRY SHALL BE TOOTHED INTO THE EXISTING COURSING TO ACHIEVE A UNIFORM JOINT PATTERN TO MATCH THE EXISTING.

R4. ALL NEW MASONRY WALLS AND INFILLS THAT ARE IN CONTINUANCE WITH EXISTING MASONRY WALLS SHALL BE TOOTHED INTO THE EXISTING COURSING TO ACHIEVE A UNIFORM JOINT PATTERN TO MATCH THE EXISTING, FIELD VERIFY WALL THICKNESS.

R5. IN ALL RENOVATED AREAS OF THE WORK, THE INTENT OF THESE CONTRACT DOCUMENTS IS TO PROVIDE A LEVEL OF QUALITY FOR ALL PATCHED SURFACES EQUAL TO THAT OF NEW SURFACES, INCLUDING BUT NOT LIMITED TO PLASTER, GYPSUM WALL BOARD AND MASONRY.

R6. ALL EXISTING MATERIALS AND FINISHES DISTURBED OR INTERRUPTED BY THE WORK SHALL BE REPLACED OR "FILLED IN" TO ACHIEVE UNIFORM COLOR, TEXTURE, PATTERN AND APPEARANCE TO MATCHING ADJACENT MATERIALS AND FINISHES. TRANSITIONS BETWEEN EXISTING TO EXISTING AND NEW TO EXISTING MATERIALS AND FINISHES SHALL BE ACHIEVED IN STRAIGHT HORIZONTAL AND OR VERTICAL LINES BETWEEN DIFFERENT AND OR NEW MATERIALS AND FINISHES.

R7. PATCH ALL HOLES IN FLOORS, WALLS AND CEILINGS, LEVEL WITH EXISTING ADJACENT SURFACES TO RECEIVE NEW FINISHES AND/OR CONSTRUCTION TO COMPLETE THE WORK. MATCH THE EXISTING ADJACENT MATERIALS, PATTERNS AND FINISHES.

R8. PATCH, REPAIR OR REPLACE ALL EXISTING FINISHES AND MATERIALS DISTURBED DURING CONSTRUCTION OR AS A RESULT OF DEMOLITION OR REMOVAL OF AN ITEM. ALL REPAIR OR REPLACEMENT SHALL MATCH ADJACENT EXISTING AND/OR NEW FINISHES, PATTERNS AND MATERIALS. SEE ROOM FINISH SCHEDULE FOR NEW FINISHES.

R9. PREPARE EXISTING REMAINING WORK SUBSTRATES TO RECEIVE NEW FINISHES AS INDICATED ON THE ROOM FINISH SCHEDULE. SUBSTRATE PREPARATION SHALL BE IN CONFORMANCE WITH THE INSTALLATION REQUIREMENTS OF EACH NEW FINISH.

R10. ALL WALLS SHOWN WITH MASONRY HATCHING WITHIN THE EXISTING BUILDING SHALL BE NEW AND TOOTHED INTO EXISTING MASONRY. MATCH EXISTING COURSING, JOINT PATTERN AND THICKNESS UNLESS NOTED OTHERWISE.

R11. MASONRY WALLS AND INFILLS THAT ARE IN CONTINUANCE WITH EXISTING MASONRY WALLS SHALL BE TOOTHED INTO THE EXISTING COURSING TO ACHIEVE A UNIFORM JOINT PATTERN TO MATCH THE EXISTING WORK. MATCH EXISTING WALL THICKNESS.

R12. AT THE DEMOLITION OF AN EXISTING ITEM, REMOVE ALL TRACES OF THE DEMOLISHED ITEMS COMPONENTS FROM THE SURFACE OF THE REMAINING FLOOR, WALLS AND CEILING. AT THE REMOVED FASTENERS IN ALL EXISTING MASONRY WALLS AND FLOORS, PATCH HOLE WITH GROUT LEVEL WITH EXISTING ADJACENT SURFACES IN ORDER TO RECEIVE NEW FINISHES.

R13. AT EXISTING FLOORS: CUT IN PLACE CONSTRUCTION TO RECEIVE NEW WORK. REPLACE WITH MATERIALS TO MATCH EXISTING REMAINING MATERIALS. PATCH FLUSH TO ADJACENT EXISTING ELEVATIONS. APPLY CEMENTITIOUS UNDERLAYMENT TO PRODUCE A UNIFORM SURFACE IN ALL AREAS RECEIVING NEW FINISHES AS INDICATED ON THE ROOM FINISH SCHEDULE. PATCHED JOINTS SHALL NOT TELEGRAPH THRU THE NEW FINISH. SEE DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS AND OTHER FINISHES.

R14. AT EXISTING FLOORS: WHERE WALLS ARE SCHEDULED FOR DEMOLITION AND EXTEND TO BELOW THE CONTINUOUS CONCRETE FLOOR SLAB, THE WALL SHALL BE DEMOLISHED TO BELOW THE FLOOR THICKNESS. THE FLOOR SHALL BE PATCHED WITH CONCRETE AND GRANULAR FILL TO MATCH THE EXISTING THICKNESS, PROVIDE NEW VAPOR BARRIER TO THE PATCHED AREA. PATCH FLUSH TO ADJACENT EXISTING ELEVATIONS. APPLY CEMENTITIOUS UNDERLAYMENT TO PRODUCE A UNIFORM SURFACE IN ALL AREAS RECEIVING NEW FINISH AS INDICATED ON ROOM FINISH SCHEDULE. PATCHED JOINTS SHALL NOT TELEGRAPH THRU THE NEW FINISH.

R15. PAINT EXISTING METALS: AT EXISTING DOOR FRAMES TO REMAIN AND OTHER PAINTED METAL COMPONENTS INDICATED. REMOVE ALL DIRT, LOOSE PAINT AND RUST, SAND ENTIRE FRAME, PRIME AND PAINT. COLOR SELECTION BY ARCHITECT. WHERE THE EXISTING PAINT IS INCOMPATIBLE WITH NEW PAINT COATINGS, THE EXISTING PAINT SHALL BE COMPLETELY REMOVED.

R16. PAINT SURFACES: WHERE PATCHING OCCURS IN THE WORK OF AN EXISTING PAINTED SURFACE, THE PATCHED AREA SHALL BE SPACKLED, PRIMED AND INTERMEDIATE PAINT COATS APPLIED OVER THE PATCH. APPLY FINAL PAINT COAT OVER ENTIRE UNBROKEN SURFACE CONTAINING THE PATCH. THE UNBROKEN SURFACE SHALL BE FROM THE INTERSECTION OF THE WALL TO FLOOR TO THE INTERSECTION OF THE WALL TO CEILING AND FROM THE RIGHT SIDE WALL TO WALL INTERSECTION TO THE LEFT SIDE WALL TO WALL INTERSECTION. PROVIDE ADDITIONAL SPACKLING AND/OR PAINT COATS UNTIL THE PATCH AREAS BLEND INVISIBLY INTO THE ADJACENT EXISTING SURFACE. UNBROKEN CEILING SURFACES SHALL BE FROM CEILING TO WALL INTERSECTION AND OR NEW BULKHEAD CEILING ELEVATION CHANGE FOR THE ENTIRE PERIMETER OF THE CEILING AREA. APPLY PAINT COATS AS DESCRIBED FOR THE WALLS.

R17. AT EXISTING CERAMIC TILE: AT DEMOLISHED ITEMS AND DAMAGED AREAS, FILL ALL HOLES IN EXISTING CERAMIC WALL AND FLOOR TILE THAT ARE UP TO 1" WITH A COLOR EPOXY GROUT TO MATCH THE EXISTING CERAMIC TILE COLOR. REMOVE AND REPLACE EXISTING TILES AT HOLES THAT ARE OVER 1" AND AT ALL BROKEN AND MISSING WALL AND FLOOR TILES WITH A NEW TILE TO MATCH EXISTING COLOR AND SIZE.

DEMOLITION LEGEND

TAG DEMOLITION NOTE9 EXISTING DOOR AND FRAME TO REMAIN. ALL SECURITY GRILL ASSEMBLIES AND COVERS, CLOSERS, CONDUIT AND WIRING, STAPLES

AND ASSOCIATED ACCESSORIES AND FASTENERS SHALL BE REMOVED IN THEIR ENTIRETY FROM BOTH SIDES OF DOOR AND FRAME.REPLACE ANY COMPONENTS OR PANELS OF DOOR THAT ARE MISSING, INCLUDING GLASS, OR METAL MESH WITH SOLID WOOD,UNLESS OTHERWISE INDICATED. INFILL OLD HARDWARE PENETRATIONS IN DOOR AND FRAME WITH WOOD INFILL AND PREPAREDOORS TO RECEIVE NEW HARDWARE AND FINISH AS SCHEDULED.

10 EXISTING DOOR AND HARDWARE TO BE REMOVED IN ITS ENTIRETY FROM BOTH SIDES OF FRAME, INCLUDING BUT NOT LIMITED TO,SECURITY GRILL ASSEMBLIES, CLOSERS, CONDUIT AND WIRING, AND ASSOCIATED ACCESSORIES AND FASTENERS. EXISTING FRAMETO REMAIN; REMOVE ANY AND ALL FASTENERS AND ADHESIVES, INFILL OLD HARDWARE PENETRATIONS IN FRAME WITH WOOD INFILLAND PREPARE OPENINGS ON BOTH SIDE FOR NEW FINISH AS SCHEDULED.

11 EXISTING BUILT-IN CASEWORK, BUILT-IN SHELVING AND/OR COAT HOOKS AND ASSOCIATED BLOCKING AND FASTENERS SHALL BEREMOVED IN THEIR ENTIRETY. PATCH AND PREPARE ALL ADJACENT FINISHES FOR NEW WORK AND FINISH AS SCHEDULED. WHEREFLOOR-MOUNTED CASEWORK IS REMOVED, PATCH EXISTING WOOD FLOORING, BASE AND ALL ADJACENT SURFACES. TOOTH WOODFLOORING INTO EXISTING; MATCH FLOORING WIDTH AND STYLE. PATCH EXISTING WOOD TRIM TO MATCH EXISTING, ADJACENT.REFER TO TYPICAL DETAIL 2/D1.1 FOR MORE INFORMATION.

12 REMOVE EXISTING WOOD PANELS, DOORS, SHELVING AND HARDWARE. EXISTING WOOD TRIM AND PLATFORM TO REMAIN AND SHALLBE STRIPPED, SANDED, PATCHED OF ANY PENETRATIONS AND PREPARED TO RECEIVE NEW FINISH AS SCHEDULED. PATCH ANDPREPARE ALL ADJACENT SURFACES FOR NEW WORK.

13 REMOVE EXISTING FOLDING PARTITION IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO, ANY ASSOCIATED HARDWARE, TRACKS,AND DISPLAY BOARDS. EXISTING WOOD TRIM AROUND PERIMETER OF EXISTING PARTITION OPENING TO REMAIN AND SHALL BESTRIPPED, SANDED, PATCHED OF ANY PENETRATIONS AND PREPARED TO RECEIVE NEW FINISH AS SCHEDULED. PREPARE ADJACENTFINISHES FOR NEW WORK.

14 REMOVE EXISTING UNIT VENTILATOR AND/OR RADIATOR COVER. CLEAN ASSEMBLY AND ALL ASSOCIATED COMPONENTS ANDPREPARE FOR NEW COVER AS SCHEDULED. PREPARE ADJACENT SURFACES FOR NEW WORK.

15 EXISTING UNIT VENTILATOR AND/OR RADIATOR COVER TO BE REMOVED, REFINISHED AND REINSTALLED AS SCHEDULED. CLEAN UNITVENTILATOR AND/OR RADIATOR AND ALL ASSOCIATED COMPONENTS PRIOR TO REINSTALLATION OF COVER.

16 PREPARE EXISTING DISPLAY BOARDS AND TRIM FOR NEW FINISH AS SCHEDULED. DISPLAY BOARDS SHALL BE FREE OF ANYFASTENERS, STAPLES AND ADHESIVES. REMOVE ANY/ALL ABANDONED OR UNUSED CONDUIT, WIRING, FASTENERS, BRACKETS,PROJECTORS AND MOUNTS, PROJECTOR SCREENS AND ASSOCIATED ACCESSORIES IN THEIR ENTIRETY. ALL ABANDONED ORUNUSED CONDUIT, WIRING AND PIPING SHALL BE REMOVED TO ABOVE CEILING, MINIMUM. ENTIRE ASSEMBLY TO BE THOROUGHLYCLEANED, SANDED, PATCHED OF ANY PENETRATIONS OR CRACKING AND PREPARED FOR NEW FINISH AND INFILL AS SCHEDULED.

17 EXISTING SHELVING WITHIN CLOSET SHALL BE REMOVED AND REPLACED IN KIND. PROVIDE A METAL BRACKET, ON CENTER, AT REAROF CLOSET TO FURTHER SUPPORT NEW SHELVES. 5 SHELVES, MINIMUM, PER CLOSET SHALL BE PROVIDED.

18 EXISTING BUILT-IN CASEWORK TO REMAIN. STRIP, SAND AND PREPARE EXISTING ASSEMBLY AND ASSOCIATED COMPONENTS FORNEW WORK AS SCHEDULED.

19 REMOVE ALL FLOOR MOUNTED FIXTURES, FLOOR DRAIN COVERS AND TOILET ROOM ACCESSORIES INCLUDING, BUT NOT LIMITED TO,SOAP DISPENSERS, PAPER TOWEL DISPENSERS, TOILET PAPER DISPENSERS, MIRRORS, SOAP DISHES, ETC FROM ROOM IN THEIRENTIRETY. RETURN ALL ACCESSORIES TO OWNER. WHERE RECESSED SOAP TRAYS OCCUR, REMOVE AND PATCH WALL TO RECEIVENEW FINISH AS SCHEDULED. REFER TO ENGINEERING DRAWINGS FOR FURTHER INFORMATION WHERE OCCURS.

20 REMOVE PLUMBING FIXTURES AND PREPARE FOR NEW WORK AS SCHEDULED. IF FIXTURE IS TO BE REMOVED AND CAPPED, PROVIDEMETAL PLATE OVER ANY PENETRATIONS AND PAINT TO MATCH ADJACENT FINISH, UNLESS OTHERWISE INDICATED. REFER TOENGINEERING DRAWINGS FOR FURTHER INFORMATION WHERE OCCURS.

DEMOLITION LEGEND

TAG DEMOLITION NOTE1 EXISTING WOOD FLOORING, BASE, STAIRS AND PLATFORMS (WHERE OCCUR) SHALL BE STRIPPED AND SANDED IN THEIR ENTIRETY.

REMOVE ALL TRANSITION STRIPS (WHERE OCCUR) AND PREPARE FOR NEW TRANSITION STRIPS AT ALL MATERIAL TRANSITIONS ASSCHEDULED. ASSUME 50 SF OF EXISTING WOOD FLOORING TO REMAIN THROUGHOUT ENTIRE PROJECT WILL REQUIRE PATCHING;FOR PATCHING PROVIDE SAME WIDTH AND THICKNESS OF FLOORING TO MATCH AND TOOTH INTO EXISTING. PREPARE FLOORS ANDINFILLS FOR NEW FINISH AS SCHEDULED.

2 REMOVING EXISTING FLOORING AND BASE IN ITS ENTIRETY INCLUDING EXISTING FINISH, TRANSITION STRIPS AND SUBFLOOR.PREPARE STRUCTURE TO RECEIVE NEW SUBFLOORING, FINISH AND TRANSITIONS AS SCHEDULED.

3 REMOVE EXISTING TOILET PARTITIONS AND ASSOCIATED ACCESSORIES AND HARDWARE. STORE FOR THE DURATION OFCONSTRUCTION AND REINSTALL IN SAME LOCATION. PATCH AND PREPARE ADJACENT SURFACES FOR FINISH AS SCHEDULED.

4 EXISTING HARD AND/OR TIN CEILING SHALL BE SCRAPPED; REMOVE ANY/ALL ABANDONED OR UNUSED CONDUIT, WIRING,FASTENERS, BRACKETS, PROJECTORS AND MOUNTS AND ASSOCIATED ACCESSORIES IN THEIR ENTIRETY. ALL ABANDONED ORUNUSED CONDUIT, WIRING AND PIPING SHALL BE REMOVED TO THE SOURCE OF SUPPLY. PATCH ANY AND ALL PENETRATIONS ANDCRACKING THROUGHOUT AND PREPARE CEILINGS, BEAMS, EXPOSED PIPING AND CONDUIT AND ASSOCIATED ACCESSORIES TORECEIVE NEW FINISH MATCHING ADJACENT SURFACE AS SCHEDULED. WHERE CAPPING OF OLD OR ABANDONED SYSTEMS OCCURS,PROVIDE COVER PLATE AND PAINT TO MATCH EXISTING SURFACES. REFER TO ENGINEERING DRAWINGS FOR FURTHERINFORMATION WHERE OCCURS.

5 EXISTING WALLS SHALL BE SCRAPPED; REMOVE ANY/ALL ABANDONED OR UNUSED CONDUIT, WIRING, FASTENERS, BRACKETS,PROJECTORS AND MOUNTS, PROJECTOR SCREENS AND ASSOCIATED ACCESSORIES IN THEIR ENTIRETY. ALL ABANDONED ORUNUSED CONDUIT, WIRING AND PIPING SHALL BE REMOVED TO THE SOURCE OF SUPPLY. PATCH ANY AND ALL PENETRATIONS ANDCRACKING THROUGHOUT AND PREPARE WALLS, COLUMNS, EXPOSED PIPING AND CONDUIT AND ASSOCIATED ACCESSORIES TORECEIVE NEW FINISH MATCHING ADJACENT FINISHED SURFACE AS SCHEDULED. WHERE CAPPING OF OLD OR ABANDONED SYSTEMSOCCURS, PROVIDE COVER PLATE AND PAINT TO MATCH EXISTING SURFACES. WHERE PIPE INSULATION IS ABATED IN ACCORDANCEWITH THE DISTRICT ASBESTOS INSPECTION REPORT AND THE ENVIRONMENTAL REMEDIATION SCOPE OF WORK PROVIDE NEWJACKETED FIBERGLASS PIPE INSULATION, JOHNS MANVILLE MICRO-LOK OR EQUAL, TO REPLACE THE REMOVED MATERIAL. NEWINSULATION SHALL EXTEND TO UNDERSIDE OF CEILING AND PAINTED TO MATCH ADJACENT FINISH SURFACE AS SCHEDULED. REFERTO ENGINEERING DRAWINGS FOR FURTHER INFORMATION WHERE OCCURS.

6 REMOVE SUSPENDED CEILING ASSEMBLY IN ITS ENTIRETY. PREPARE ADJACENT SURFACES FOR NEW CEILING ASSEMBLY ASSCHEDULED.

7 EXISTING TRIM THROUGHOUT ENTIRE ROOM INCLUDING, BUT NOT LIMITED TO, EXTERIOR AND INTERIOR WINDOW TRIM ANDINTERMITTENT WOOD MULLIONS, BASE AND CROWN MOLDING, SHALL BE STRIPPED, SANDED, PATCHED OF ANY PENETRATIONS ANDPREPARED TO RECEIVE NEW FINISH AS SCHEDULED. ALL EXISTING WINDOW SHADES AND ASSOCIATED COMPONENTS SHALL BEREMOVED IN THEIR ENTIRETY. EXISTING OPAQUE EXTERIOR WINDOW PANELS AND INTERIOR PANEL INFILLS SHALL BE PREPAREDAND PAINTED TO MATCH ADJACENT FINISH SURFACE AS SCHEDULED. EXTERIOR METAL WINDOW FRAMES, SOLID POLYMER SILLS,SECURITY GRILLES AND GUARDS, AND ALL TRANSPARENT GLAZING SHALL BE THOROUGHLY CLEANED OF ALL ADHESIVES, STAPLESAND UNUSED FASTENERS.

8 EXISTING DOOR AND HARDWARE TO BE REMOVED IN ITS ENTIRETY FROM BOTH SIDES OF FRAME, INCLUDING BUT NOT LIMITED TO,SECURITY GRILL ASSEMBLIES, CLOSERS, CONDUIT AND WIRING, AND ASSOCIATED ACCESSORIES AND FASTENERS. EXISTING FRAMETO REMAIN; REMOVE ANY AND ALL FASTENERS AND ADHESIVES AND PATCH AND PREPARE BOTH SIDES OF FRAME AND ADJACENTWALLS TO RECEIVE NEW DOOR AND HARDWARE AND FINISH AS SCHEDULED.

3" = 1'-0"D1.1

2 WOOD TRIM BASE DETAIL - TYPICAL

1

Page 4: THE SCHOOL DISTRICT OF PHILADELPHIA BOARD OF …€¦ · Markerboards and tackboards shall be supplied by the SDP and installed by the contractor. The contractor shall coordinate

KINDERGARTEN CLASSROOM

101

PLATFORM

101A

STORAGE

101B

KINDERGARTEN CLASSROOM

102

STORAGE

102D

STORAGE

102C

TOILET

102E

TOILET

101D

-TYP

ACCENT PAINT 'B'

-TYP

ACCENT PAINT 'B'

I4.5 P

I4.5

Q

U

I4.5

100

100

100

100

100

100

100

100

100

100

100

100

100 100 100

100100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

-TY

P

AC

CE

NT

PA

INT

'B'

100

100

100

100 100 100 100 100 100 100 100 100

100

100

100

PROVIDE TOPFILLER -TYP

KINDERGARTEN CLASSROOM

103

TOILET

103A

I4.5

H

I4.5

J

J

SIM

SIM

I4.5

F

G

SIM

SIM

I4.5

H

SIM

I4.5J

SIM

I4.5 FI4.5

G

SIM

SIM

I4.5

H

SIM

I4.5H

SIM

N

I4.5

SIM

PROVIDE TOPFILLER -TYP

PROVIDE TOPFILLER -TYP

PROVIDE TOPFILLER -TYP

PROVIDE TOPFILLER -TYP

65 7

4

4

4

4

67

5

4

75

4

6

PROVIDE TOPFILLER -TYP

ACCENT PAINT 'A'

ACCENT PAINT 'A'-TYP

TERMINATEACCENT PAINT 'A'

TERMINATEACCENT PAINT 'A' ACCENT

PAINT 'A'-TYP

ACCENT PAINT 'A'-TYP

ACCENT PAINT 'A'-TYPACCENT

PAINT 'A'-TYP

726

726

718

718

709

723

SIM

723 711

719 719723

709

719

719

723

709

725719 719

710

I4.5

M

727

706

I4.5

K

I4.5 L

1ST GRADE CLASSROOM

106

1ST GRADE CLASSROOM

105

1ST GRADE CLASSROOM

104

TOILET

104A

- T

YP

AC

CE

NT

PA

INT

'B'

- T

YP

AC

CE

NT

PA

INT

'B'

- T

YP

AC

CE

NT

PA

INT

'B'

(15) HOOKS - LAYOUT 'A'

(13) HOOKS - LAYOUT 'A'

(4) HOOKS -LAYOUT 'A'

(14) HOOKS - LAYOUT 'A'

(4) HOOKS -LAYOUT 'A'

(12) HOOKS - LAYOUT 'A'

(10) HOOKS - LAYOUT 'A'

(10) HOOKS - LAYOUT 'A'

(3) HOOKS - LAYOUT 'B'

(2) HOOKS - LAYOUT 'A'

I4.5

J

I4.5

J

SIM

I4.5

J

SIM

I4.5 H

SIM

I4.5H

SIM

I4.5

J

SIM

I4.5 H

SIM

I4.5H

SIM

I4.5 H

SIM

I4.5H

SIM

4

7

6

5

4

ACCENT PAINT 'A'-TYP

ACCENT PAINT 'A'-TYP

ACCENT PAINT 'A'-TYP

723

711

723

719

719

709

719

719

723

723

SIM

723

711

723

719

719

709

719

719

723

723

723

719

719

709

719

719

723

723

724

712

726

718

1’ − 2"

WOODINTERIOR SURFACES

WOODDOOR FRONT W/WOOD EDGING

STAINLESS STEELPULL

COAT HOOKSSTAINLESS STEEL-TYP

PROVIDE 5/8" PLYWOOD BACKER W/HIGH PRESSURE LAMINATE ON ALL

EXPOSED SURFACES (WHERE OCCURS)WITH HEAVY DUTY SUPPORT BRACKETS PER MANUFACTURER'S RECOMMENDATIONS. BACKER TO BE CONTINUOUS ALONG WALL. VERIFY IN FIELD ALL LENGTHS PRIOR TO FABRICATION.

BASE AS SCHEDULED

3/4" WOOD1-ADJ. SHELF

(WH

ER

E O

CC

UR

S)

WA

LL C

AB

INE

T A

S S

CH

ED

ULE

D

-TY

P

19"

O.C

.

34"

O.C

.

9"

EXISTING FRAME(WHERE OCCURS)

EXISTING WALLEXISTING CEILING

AF

F

48"

LOCATION NO. FILE NO.

DRAWN BY CHECKED BY

DRAWING NO.

1

NO. DATE REVISION

www.philasd.org

SCHOOL & LOCATION

PROJECT TITLE

DRAWING TITLE

87654321

A

B

C

D

E

F

P H I L A D E L P H I A

(215) 400 - 4730 (215) 400 - 4731 (fax)

440 NORTH BROAD STREETPHILADELPHIA, PA 19130 - 4015

OFFICE OF CAPITAL PROGRAMS

T H E S C H O O L D I S T R I C T O F

SEAL:

R. JEFFREY STRAUB

STATE AND LICENSE NO: RA403652

Attn: Jessie Harder

Email: [email protected]

Phone: 717-458-0272

Mechanicsburg, PA 17055

401 E. Winding Hill Road

CRABTREE, ROHRBAUGH & ASSOCIATES

ARCHITECT

Attn: Deepak Ajjimane

Email: [email protected]

Phone: 667-309-6036

Baltimore, MD 21202

One South Street, Suite 1130

SETTY

MEP ENGINEERS

2

3

4

5

6

7

8

9

10

ADDENDUM #12/27/2019

B-041C OF 2018 / 19

B-042C OF 2018 / 19

CRA NO.3223

LARGE SCALE PLANS -KINDERGARTEN & FIRSTGRADE CLASSROOMS

01/18/2019

I4.2

W.C. BRYANT SCHOOL

6001 CEDAR AVENUE,

PHILADELPHIA, PA 19143

100% CONSTRUCTION

CLASSROOMMODERNIZATION

1/4" = 1'-0"I4.2

1 KINDERGARTEN 101, 102, 103

PRE-K & KINDERGARTEN MOUNTING HEIGHT SCHEDULE

MARKER BOARD 2'-0" AFF TO BOTTOM EDGE

TACK BOARD 2'-0" AFF TO BOTTOM EDGE

NOTE: WHERE NEW MARKER BOARD OR TACK BOARD IS BEING MOUNTED NEXT TO OR ON THE SAME WALL AS AN EXISTING TACK BOARD OR MARKER BOARD MATCH EXISTING HEIGHT.

1/4" = 1'-0"I4.2

2 FIRST GRADE 106, 105, 104

TOILET ACCESSORY SCHEDULE

No. DESCRIPTION MOUNTING MANUFACTURER MODEL1 SURFACE MTD. S.S. COAT HOOK GC SUPPLIED AND INSTALLED

4 TOILET PAPER DISPENSER GC SUPPLIED AND INSTALLED RENOWN REN05151-IB

5 SURFACE MTD PAPER TOWEL DISPENSER GC SUPPLIED AND INSTALLED RENOWN REN05173-WB

6 SOAP DISPENSER GC SUPPLIED AND INSTALLED KIMBERLY-CLARK PROFESSIONAL 1000mL SKIN CARE

7 MIRROR 18" x 30" w/ SS FRAME GC SUPPLIED AND INSTALLED

1. HANDICAPPED FIXTURES ARE INDICATED WITH THE REQUIRED CLEAR FLOOR SPACECLEARANCES FOR ALL ACCESSIBLE ROUTES & MANEUVERING CLEARANCES.

2. PLUMBING FIXTURE ROUGH-IN DIMENSIONS & TOILET PARTITION LAYOUT DIMENSIONSARE FROM THE WALL FINISH MATERIAL.

3. PROVIDE WOOD BLOCKING IN STUD WALLS FOR ALL TOILET ACCESSORIES.

4. TOILET PARTITION DIMENSIONS ARE TO THE PANEL CENTERLINE UNLESS NOTEDOTHERWISE. MINIMUM CLEAR DIMENSIONS MUST BE PROVIDED WHERE NOTED.

5. COORDINATE ALL WALL FINISHES WITH THE ROOM FINISH SCHEDULE.

6. CONTRACTOR TO CONFIRM WITH THE OWNER'S REPRESENTATIVE THE LOCATION OF ALL SURFACE-MOUNTED TOILET ROOM ACCESSORIES PRIOR TO INSTALLATION.

7. URINAL PARTITIONS SHALL BEGIN AT A HEIGHT NO MORE THAN 12" FROM AND EXTENDNOT LESS THAN 60" ABOVE THE FINISHED FLOOR SURFACE. URINAL PARTITIONS SHALL EXTEND FROM THE WALL SURFACE AT EACH SIDE OF THE URINAL A MINIMUM OF 18".

GENERAL NOTES:

GRADE 1-3 MOUNTING HEIGHT SCHEDULE

MARKER BOARD 2'-6" AFF TO BOTTOM EDGE

TACK BOARD 2'-6" AFF TO BOTTOM EDGE

WALL CABINETS SEE TYPICAL SECTION DETAIL

SMART-BOARD CENTERED ON THE MARKER BOARD

NOTE: WHERE NEW MARKER BOARD OR TACK BOARD IS BEING MOUNTED NEXT TO OR ON THE SAME WALL AS AN EXISTING TACK BOARD OR MARKER BOARD MATCH EXISTING HEIGHT.

I4.2 - GENERAL CASEWORK AND EQUIPMENT SCHEDULE

NO DESCRIPTION MANUFACTURER MODEL DIMENSIONS100 OPEN STUDENT WARDROBE W/(1) DOUBLE HOOK & (2) SINGLE

HOOKS EACH. MODIFIED TO INCLUDE (2) FIXED SHELVES. SEECUBBIE DETAIL.

SEE SPECIFICATIONS -- 15"W x 12"D x 54"H

706 TACK STRIP OWNER SUPPLIED, GC INSTALLED SEE SPECIFICATIONS WIDTH TO FIT x 2"H

709 FRAMELESS MARKERBOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 14'-0"W (VIF) x 4'-0"H (VIF)

710 FRAMELESS MARKERBOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 10'-0"W (VIF) x 4'-0"H (VIF)

711 FRAMELESS TACK BOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 14'-0"W (VIF) x 4'-0"H (VIF)

712 FRAMELESS TACK BOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 12'-0"W (VIF) x 4'-0"H (VIF)

718 FRAMELESS TACK BOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 4'-0"W (VIF) x 4'-0"H (VIF)

719 FRAMELESS TACK BOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 3'-0"W (VIF) x 5'-0"H (VIF)

723 FRAMELESS TACK BOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 14'-0"W (VIF) x 1'-0"H (VIF)

724 FRAMELESS TACK BOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 12'-0"W (VIF) x 1'-0"H (VIF)

725 FRAMELESS TACK BOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 10'-0"W (VIF) x 1'-0"H (VIF)

726 FRAMELESS TACK BOARD INFILL SEE SPECIFICATIONS SEE SPECIFICATIONS 4'-0"W (VIF) x 1'-0"H (VIF)

727 MARKERBOARD W/WOOD FRAME OWNER SUPPLIED, GC INSTALLED SEE SPECIFICATIONS 12'-0"W x 4'-0"H

1

1

1

1

1" = 1'-0"I4.2

3 WOOD WALL CABINET & COAT HOOK DETAIL1

Page 5: THE SCHOOL DISTRICT OF PHILADELPHIA BOARD OF …€¦ · Markerboards and tackboards shall be supplied by the SDP and installed by the contractor. The contractor shall coordinate

O.C

.

34"

PROVIDE 5/8" PLYWOOD BACKER WITH HIGH PRESSURE LAMINATE ON ALL EXPOSED SURFACES WITH HEAVY DUTY SUPPORT BRACKETS PER MANUFACTURER'S RECOMMENDATIONS. BACKER TO BE CONTINUOUS ALONG WALL. VERIFY IN FIELD ALL LENGTHS PRIOR TO FABRICATION.

(30) HEAVY DUTY DOUBLE WARDROBE COAT HOOKS SHALL BE PROVIDED WITHIN EACH SPACE AS INDICATED ON THE FLOOR PLANS.

O.C.

14"

-TY

P

9 1/

2"

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

PROVIDE 5/8" PLYWOOD BACKER WITH HIGH PRESSURE LAMINATE ON ALL EXPOSED SURFACES WITH HEAVY DUTY SUPPORT BRACKETS PER MANUFACTURER'S RECOMMENDATIONS. BACKER TO BE CONTINUOUS ALONG WALL. VERIFY IN FIELD ALL LENGTHS PRIOR TO FABRICATION.

(30) HEAVY DUTY DOUBLE WARDROBE COAT HOOKS SHALL BE PROVIDED WITHIN EACH SPACE AS INDICATED ON THE FLOOR PLANS.

-TY

P

19"

7" 7"

O.C.

14"

O.C

.

8"

O.C

.

34"

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

AF

F

48"

3

I4.2

Sim

NOTE: ALL EXISTING WOOD FRAME DISPLAY BOARDS TO BE STRIPPED, SANDED AND PATCHED OF ANY PENETRATIONS. EXISTING AND NEW WOOD TRIM TO BE FINISHED TO MATCH AS SCHEDULED.

INLAY 1/2" QUARTER-ROUND WOOD TRIM, CONTINUOUS, AROUND PERIMETER OF ALL DISPLAY BOARD INFILLS, TYPICAL. FINISH TO MATCH EXISTING FRAME AS SCHEDULED.

TACKBOARD INFILL, TYPICAL

MARKERBOARD INFILL, TYPICAL

VA

RIE

S (

VIF

)

5' -

0"

(VIF)

VARIES

(VIF)

VARIES

(VIF)

VARIES

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

INTERACTIVE DISPLAY BOARD

(WHERE OCCURS)-NIC

PROVIDE SIMULATED STONE TOPSPANNING FROM INDICATED CUBBIE EDGE TO ALL EXISTING WALLS WITHIN ALCOVE, TYPICAL

CEILING AS SCHEDULED

EXISTING FRAMED OPENING -FINISH AS SCHEDULED

EXISTING CONSTRUCTION

WHERE OCCURS, REMOVE APPROX. 2" FROM BASE OF CUBBIE TO ACCOMMODATE EXISTING PLATFORM. MAINTAIN HEIGHT REQUIRED FROM CLASSROOM FINISH FLOOR. VERIFY HEIGHT IN FIELD PRIOR TO FABRICATION

BLOCKING

FINISH FLOOR

EXISTING PIPING (WHERE OCCURS)

VARIES

3/4" TYP

3/8"

N

I4.5

100 100 100 100 100 100 100 100 100 100

FULL HEIGHT FINISHED END PANEL

REMOVE EXISTING GLASS AND TRIM IN THEIR ENTIRETY. INFILL EXISTING DOOR PANEL WITH PLYWOOD BACKER AND TACKBOARD INFILL, TYPICAL

SAND EXISTING BASE, TRIM AND DOORS. REMOVE ANY AND ALL NAILS, STAPLES, ADHESIVES ETC. PREPARE ENTIRE ASSEMBLY TO BE REFINISHED AS SCHEDULED.

INLAY 1/2" QUARTER-ROUND WOOD TRIM, CONTINUOUS, AROUND PERIMETER OF ALL DISPLAY BOARD INFILLS, TYPICAL. FINISH TO MATCH EXISTING FRAME AS SCHEDULED.

PROVIDE NEW DOOR HARDWARE, TYPICAL

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

INTERACTIVE DISPLAY BOARD

(WHERE OCCURS)-NIC

-TY

P12

"

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

SEE FLOOR PLAN

VARIES

I4.5

N

-TY

P12

"

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

SEE FLOOR PLAN

VARIES

100 100 100

TOP FILLER PANEL (WHERE OCCURS)

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

100100100100100100100

TOP FILLER PANEL (WHERE OCCURS)

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

INTERATICE DISPLAY BOARD

(WHERE OCCURS)-NIC

-TY

P12

"

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

SEE FLOOR PLAN

VARIES

-TY

P12

"

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

SEE FLOOR PLAN

VARIES

NOTE: ALL EXISTING WOOD FRAME DISPLAY BOARDS TO BE STRIPPED, SANDED AND PATCHED OF ANY PENETRATIONS. EXISTING AND NEW WOOD TRIM TO BE FINISHED TO MATCH AS SCHEDULED.

INLAY 1/2" QUARTER-ROUND WOOD TRIM, CONTINUOUS, AROUND PERIMETER OF ALL DISPLAY BOARD INFILLS, TYPICAL. FINISH TO MATCH EXISTING FRAME AS SCHEDULED.

TACKBOARD INFILL, TYPICAL(VIF)

VARIES

VA

RIE

S (

VIF

)1'

- 4

"

(VIF

)

4' -

0"

NOTE: COORDINATE ALL CASEWORK LAYOUTS AND VISUAL DISPLAY LAYOUTS WITH FLOOR PLAN.

IN INSTANCE WHERE FLOOR PLAN/ELEVATIONS DO NOT COINCIDE, FLOOR PLAN LAYOUT

TAKES PRECEDENCE. VISUAL DISPLAY BOARD LAYOUT AND DIMENSIONS VARY

- VERIFY IN FIELD ALL DIMENSIONS AND LAYOUTS PRIOR TO FABRICATION OR INSTALLATION.

-TY

P

6' -

0"

4"H TILE BULLNOSE CAP TRIMTOP ROW-TYP

4"H TILE COVE BASEWALL/FLOOR-TYP

1-FIXEDSHELF

2-SINGLECOAT HOOKS

1-DOUBLECOATHOOK

ADA STICKERAS INDICATEDON PLANS BASE

10"

2' -

5 1

/4"

10

3/4

"4

"

4' -

6"

1-FIXEDSHELF

PLATFORM

PROVIDEFILLER

100 100 100 100 100 100 100 100 100 100 100 100

PROVIDEFILLER

PROVIDEFILLER

100 100 100

FLOOR SURFACE

12

6"

1/2"

MA

X

3/4"

TRANSITION SHALL OVERLAP EXISTING FINISH AS NOTED

FLOOR SURFACE

SAND EXISTING BUILT-IN BOOKSHELF AND TRIM. REMOVE ANY AND ALL NAILS, STAPLES, ADHESIVES, PAPER WRAPS, ETC. PREPARE ENTIRE ASSEMBLY TO BE REFINISHED AS SCHEDULED.

FINISH FLOOR

PROVIDE SIMULATED STONE TOP

3/4" TYP

727

-TY

P12

"

706

BEYOND

LOCATION NO. FILE NO.

DRAWN BY CHECKED BY

DRAWING NO.

1

NO. DATE REVISION

www.philasd.org

SCHOOL & LOCATION

PROJECT TITLE

DRAWING TITLE

87654321

A

B

C

D

E

F

P H I L A D E L P H I A

(215) 400 - 4730 (215) 400 - 4731 (fax)

440 NORTH BROAD STREETPHILADELPHIA, PA 19130 - 4015

OFFICE OF CAPITAL PROGRAMS

T H E S C H O O L D I S T R I C T O F

SEAL:

R. JEFFREY STRAUB

STATE AND LICENSE NO: RA403652

Attn: Jessie Harder

Email: [email protected]

Phone: 717-458-0272

Mechanicsburg, PA 17055

401 E. Winding Hill Road

CRABTREE, ROHRBAUGH & ASSOCIATES

ARCHITECT

Attn: Deepak Ajjimane

Email: [email protected]

Phone: 667-309-6036

Baltimore, MD 21202

One South Street, Suite 1130

SETTY

MEP ENGINEERS

2

3

4

5

6

7

8

9

10

ADDENDUM #12/27/2019

B-041C OF 2018 / 19

B-042C OF 2018 / 19

CRA NO.3223

INTERIOR ELEVATIONS &DETAILS

01/18/2019

I4.5

W.C. BRYANT SCHOOL

6001 CEDAR AVENUE,

PHILADELPHIA, PA 19143

100% CONSTRUCTION

CLASSROOMMODERNIZATION

1/4" = 1'-0"I4.5

K CLOSET COAT HOOK LAYOUT 'A' - TYPICAL

1/4" = 1'-0"I4.5

L CLOSET COAT HOOK LAYOUT 'B' - TYPICAL

1/4" = 1'-0"I4.5

H EXISTING PRIMARY TEACHING WALL - TYPICAL

1/2" = 1'-0"I4.5

N CUBBIE SECTION DETAIL - TYPICAL

1/4" = 1'-0"I4.5

A CUBBIE LAYOUT 'A' - TYPICAL 1/4" = 1'-0"I4.5

B NEW PRIMARY TEACHING WALL 'A' - TYPICAL 1/4" = 1'-0"I4.5

C NEW SECONDARY TEACHING WALL 'A' - TYPICAL

1/4" = 1'-0"I4.5

F CLOSET CUBBIE LAYOUT 'B' - TYPICAL 1/4" = 1'-0"I4.5

G CLOSET CUBBIE LAYOUT 'B' - TYPICAL

1/4" = 1'-0"I4.5

D NEW PRIMARY TEACHING WALL 'B' - TYPICAL 1/4" = 1'-0"I4.5

E NEW SECONDARY TEACHING WALL 'B' - TYPICAL

1/4" = 1'-0"I4.5

J EXISTING DISPLAY BOARD WALL - TYPICAL

WALL PATTERN LEGEND

FLOOR TRANSITION SCHEDULE

= ACCENT 2:

= ACCENT 1:

= FIELD:

PT TO WD MARBLE

SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

1/2" = 1'-0"I4.5

T TOILET ROOM WAINSCOT PATTERN ELEVATION - TYPICAL

1/2" = 1'-0"I4.5

R SINGLE STUDENT LOCKER ELEVATION - TYPICAL

GRADE 1-3 MOUNTING HEIGHT SCHEDULE

MARKER BOARD 2'-6" AFF TO BOTTOM EDGE

TACK BOARD 2'-6" AFF TO BOTTOM EDGE

WALL CABINETS SEE TYPICAL SECTION DETAIL

SMART-BOARD CENTERED ON THE MARKER BOARD

NOTE: WHERE NEW MARKER BOARD OR TACK BOARD IS BEING MOUNTED NEXT TO OR ON THE SAME WALL AS AN EXISTING TACK BOARD OR MARKER BOARD MATCH EXISTING HEIGHT.

PRE-K & KINDERGARTEN MOUNTING HEIGHT SCHEDULE

MARKER BOARD 2'-0" AFF TO BOTTOM EDGE

TACK BOARD 2'-0" AFF TO BOTTOM EDGE

NOTE: WHERE NEW MARKER BOARD OR TACK BOARD IS BEING MOUNTED NEXT TO OR ON THE SAME WALL AS AN EXISTING TACK BOARD OR MARKER BOARD MATCH EXISTING HEIGHT.

1/4" = 1'-0"I4.5

P CUBBIE LAYOUT - KINDERGARTEN 101A 1/4" = 1'-0"I4.5

Q CUBBIE LAYOUT - KINDERGARTEN 101B 6" = 1'-0"I4.5

S WOOD & MARBLE TRANSITION DETAILS -TYPICAL

EXISTING FLOOR TRANSITION SCHEDULE(WHERE OCCURS)

WD TO SCONC

SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

VCT TO SCONC

VCT TO WD

VCT TO VAT JOHNSONITE NO. SSR-XX-B (1/8")

CT TO WD MARBLE

WOOD

JOHNSONITE NO. SSR-XX-B (1/8")

JOHNSONITE NO. SSR-XX-B (1/8")

WD TO WD WOOD

CT TO VCT MARBLE

1/2" = 1'-0"I4.5

U WALL SECTION OF EXISTING SHELVING

1/4" = 1'-0"I4.5

M SECONDARY VISUAL DISPLAY - KINDERGARTEN 102

1

1

1

1

Page 6: THE SCHOOL DISTRICT OF PHILADELPHIA BOARD OF …€¦ · Markerboards and tackboards shall be supplied by the SDP and installed by the contractor. The contractor shall coordinate

GENERAL SHEET NOTES

C

C

C C C C C C

C

C

SPA S

PA

S S S S

S

S

S

S

KEYED SHEET NOTES#

1. REFER TO DRAWING E0.1 FOR ELECTRICAL GENERAL NOTES, LEGEND AND ABBREVIATIONS.

2. REFER TO ARCHITECTURAL DRAWINGS, ELEVATION & DETAILS FOR EXACT LOCATION OF ELECTRICAL DEVICES.

3. ALL RECEPTACLES, TELE/DATA OUTLETS WITH ASSOCIATED WIRING, CONDUIT, RACEWAYS, ETC SHALL BE SURFACE MOUNTED ON EXISTING WALLS AND FLUSH MOUNTED ON NEW WALLS. REFER TO ARCHTECTUAL DRAWINGS FOR WALL TYPES.

4. ALL THE RECEPTACLES AND DATA OUTLETS WITHIN THE SCOPE OF WORK AREAS THAT ARE EXISTING TO REMAIN SHALL BE PROVIDED WITH NEW DEVICES. NEW DEVICES TO MATCH EXISTING IN KIND MAKE, TYPE AND DEVICES COLOR SHALL BE WHITE.

GFI-T

GFI-T

GFI-T

GFI-T

GFI-T

GFI-T

N.I.C.

N.I.C. N.I.C.

+96"

+48"+48"

+96"GFI-T

GFI-T

GFI-T

+96"

GFI-T

GFI-T

GFI-T

GFI-T

GFI-T

GFI-TGFI-T

+96"

E

E E

E

E

GFI-T

E

E

E

PANEL A-1 (N)

PANEL C-1 (N)

PANEL B-1 (N)

KINDERGARTENCLASSROOM

102

KINDERGARTENCLASSROOM

101

KINDERGARTENCLASSROOM

103

1ST GRADECLASSROOM

104

1ST GRADECLASSROOM

105

1ST GRADECLASSROOM

106

PRE-KINDERGARTENCLASSROOM

107

PRE-KINDERGARTENCLASSROOM

108

PRE-KINDERGARTENCLASSROOM

114

PRE-KINDERGARTENCLASSROOM

113

E

E

E E

E

+48"

+96"

GFI-T

GFI-TGFI-T

GFI-T

E

GFI-T

E

GFI-T

GFI-T

GFI-T

GFI-T

GFI-T

GFI-T

EGFI-T

GFI-T

GFI-TGFI-T

GFI-T

GFI-T

E E

E

GFI-T

GFI-T

E EE+96"

GFI-T

GFI-TGFI-T

GFI-TE

+96"

GFI-T+48" GFI-T

GFI-T

GFI-T

+96"

E

R

W

R W

R

W

R

W R W R W R W R W

R

W

RW

2

1

11

1

1

GFI-T2

1

21

1

2

1

GFI-T1

11

1

21

2

1

11 1

GFI-TGFI-T

11GFI-T

1GFI-T

GFI-T1

2

1

2

2 2

4

3

5

6

6

66

6 6 6 6

6

6

7

7

77771111

7

7

A-1-17

A-1-18

A-1-18

A-1-21

A-1-21

A-1-20

A-1-19

B-1-13

B-1-14

B-1-14

B-1-15

B-1-16

B-1-17

B-1-19

B-1-20

B-1-18

B-1-22

B-1-23

B-1-24

C-1-14

C-1-15

C-1-16

C-1-19

C-1-20

C-1-22

1

C-1-23

1

C-1-24

GFI-T

WAPE

+96"

E

AV

AV

A/CA/CE

EA/CA/CE

EA/CA/CE

E

+96"AV

E

WAPE

WAPE

WAPE

WAPE

WAPE

WAPE

WAPE

WAPE

WAPE

GFI-T

GFI-T11

1

GFI-T

1

GFI-T

1

1

1

1

GFI-T

GFI-T

1

1

GFI-T

1

+48" +48"MDF ROOM

GFI-T

8 88

8

8 8

8

8

8

89

9

9

9

99999

4

2

4

4

4

444444

2

2

2

2 2 2

2

2

2

GFI-T

GFI-T

GFI-T

GFI-T

1

GFI-TC-1-21

10 10 10 10

10

10

10

10

1. PROVIDE NEW TAMPER RESISTANT RECEPTACLE WITH COVER PLATE AND RECONNECT TO EXISTING CIRCUIT.

2. PROVIDE NEW TAMPER RESISTANT DEDICATED QUAD RECEPTACLE FOR LAPTOP CART CHARGING STATION.

3. NEW RECESSED PANELBOARD "A-1". CONTRACTOR TO UTILIZE, INTERCEPT, AND EXTEND ALL EXISTING ACTIVE FEEDER AND BRANCH CIRCUIT WIRING/CONDUIT OF SAME SIZE VIA NEW JUNCTION BOX OR PULL BOX AND CONNECT IT TO THE NEW PANELBOARD. PATCH AND PAINT WALL TO MATCH ADJACENT WALL CONTRUCTION AS REQUIRED.

4. NEW SURFACE MOUNTED PANELBOARD "B-1". CONTRACTOR TO UTILIZE, INTERCEPT, AND EXTEND ALL EXISTING ACTIVE FEEDER AND BRANCH CIRCUIT WIRING/CONDUIT OF SAME SIZE VIA NEW JUNCTIOX BOX OR PULL BOX AND CONNECT IT TO THE NEW PANELBOARD. CONTRACTOR TO PROVIDE MOUNTING ACCESSORIES AS REQUIRED.

5. NEW RECESSED PANELBOARD "C-1". CONTRACTOR TO UTILIZE, INTERCEPT, AND EXTEND ALL EXISTING ACTIVE FEEDER AND BRANCH CIRCUIT WIRING/CONDUIT OF SAME SIZE VIA NEW JUNCTION BOX OR PULL BOX AND CONNECT IT TO THE NEW PANELBOARD. PATCH WALL AND PAINT TO MATCH SURROUNDING WALL AS REQUIRED.

6. NEW LOCATION OF RELOCATED PA SPEAKER. EXTEND WIRING/CONDUIT TO NEW PA SPEAKER LOCATION, PROVIDE NEW AS REQUIRED.

7. PROVIDE NEW BATTERY OPERATED WIRELESS CLOCK. COORDINATE WITH ARCHITECT FOR EXACT MOUNTING HEIGHT.

8. CONTRACTOR TO COORDINATE IN FIELD FOR EXACT LOCATION OF RECEPTACLE AND DATA OUTLET SERVING THE INTERACTIVE SMARTBOARD TO AVOID CONFLICT WITH BASE PLATE. REFER TO ARCHITECTURAL DRAWING I4.6 DETAIL #1 AND # 2 FOR EXACT LOCATION AND MOUNTING HEIGHT.

9. CONTRACTOR TO FIELD TEST FUNCTIONLITY OF EXISTING TELEPHONE OUTLETS AND REPLACE AS REQUIRED. NEW TO MATCH EXISTING IN KIND MAKE AND TYPE.

10. INSTALL NEW PUBLIC ADDRESS SPEAKER AND WIRELESS CLOCK ON COVERPLATE PROVIDED DURING NEW CONSTRUCTION AT LOCATION OF DEMOLISHED SYNCHRONOUS CLOCK AND PUBLIC ADDRESS SPEAKER ASSEMBLY.

11. PROVIDE NEW BATTERY OPERATED WIRELESS CLOCK. INSTALL NEW WIRELESS CLOCK ON COVERPLATE PROVIDED DURING NEW CONSTRUCTION AT LOCATION OF DEMOLISHED SYNCHRONOUS CLOCK AND PUBLIC ADDRESS SPEAKER ASSEMBLY.

#

LOCATION NO. FILE NO.

DRAWN BY CHECKED BY

DRAWING NO.

1NO. DATE REVISION

www.philasd.org

SCHOOL & LOCATION

PROJECT TITLE

DRAWING TITLE

87654321

A

B

C

D

E

F

P H I L A D E L P H I A

(215) 400 - 4730 (215) 400 - 4731 (fax)

440 NORTH BROAD STREETPHILADELPHIA, PA 19130 - 4015

OFFICE OF CAPITAL PROGRAMS

T H E S C H O O L D I S T R I C T O F

SEAL:

CONRAD DELA CRUZSTATE AND LICENSE NO: 089048

Attn: Jessie HarderEmail: [email protected]

Phone: 717-458-0272Mechanicsburg, PA 17055401 E. Winding Hill RoadCRABTREE, ROHRBAUGH & ASSOCIATES

ARCHITECT

Attn: Deepak AjjimaneEmail: [email protected]

Phone: 667-309-6036Baltimore, MD 21202One South Street, Suite 1130SETTY

MEP ENGINEERS

2

3

4

5

6

7

8

9

10

ADDENDUM #12/27/19

B-041C OF 2018 / 19B-042C OF 2018 / 19

ORIGINAL DRAWING SIZE IS 30"x 42"; SCALE ENTITIES ACCORDINGLY IF REDUCED/ENLARGED SHEET OF 10

CRA NO. 3223

NS DAT

C:\Users\Nicole.serafin\Documents\3223_Electrical Link - Bryant_Nicole.Serafin.rvt2/27/2019 5:35:02 PM

ELECTRICAL OVERALL FIRSTFLOOR PLAN - POWER NEWWORK

01/18/2019

E2.1

W.C. BRYANT SCHOOL

6001 CEDAR AVENUE,PHILADELPHIA, PA 19143

100% CONSTRUCTION

CLASSROOMMODERNIZATION

1/8" = 1'-0"E2.11 ELECTRICAL POWER OVERALL FIRST FLOOR PLAN - NEW WORK

6

1

Page 7: THE SCHOOL DISTRICT OF PHILADELPHIA BOARD OF …€¦ · Markerboards and tackboards shall be supplied by the SDP and installed by the contractor. The contractor shall coordinate

GENERAL SHEET NOTES

C C C S S S S

S

C C C C

C

SPA

SPA

SPA

KEYED SHEET NOTES#

1. REFER TO DRAWING E0.1 FOR ELECTRICAL GENERAL NOTES, LEGEND AND ABBREVIATIONS.

2. REFER TO ARCHITECTURAL DRAWINGS, ELEVATION & DETAILS FOR EXACT LOCATION OF ELECTRICAL DEVICES.

3. ALL RECEPTACLES, TELE/DATA OUTLETS WITH ASSOCIATED WIRING, CONDUIT, RACEWAYS, ETC SHALL BE SURFACE MOUNTED ON EXISTING WALLS AND FLUSH MOUNTED ON NEW WALLS. REFER TO ARCHTECTUAL DRAWINGS FOR WALL TYPES.

4. ALL THE RECEPTACLES AND DATA OUTLETS WITHIN THE SCOPE OF WORK AREAS THAT ARE EXISTING TO REMAIN SHALL BE PROVIDED WITH NEW DEVICES. NEW DEVICES TO MATCH EXISTING IN KIND MAKE, TYPE AND DEVICES COLOR SHALL BE WHITE.

N.I.C.

N.I.C.

N.I.C.

GFI-T

GFI-T

GFI-T

GFI-T GFI-T

GFI-T

+96"

+96"

+96"+96"

+96"

EE

E E E

E

E

E

3RD GRADECLASSROOM

209

3RD GRADECLASSROOM

208 3RD GRADECLASSROOM

207

3RD GRADECLASSROOM

206

2ND GRADECLASSROOM

205

2ND GRADECLASSROOM

204

2ND GRADECLASSROOM

203

2ND GRADECLASSROOM

202

PANEL B-2 (N)

PANEL A-2 (E)

PANEL C-2 (N)

E E

E

E

E

E

E

E

W

R

R WR WR WR WW

R

W

R

W

1

1111

111

2

3

5

10

5

10 10

5 4 5 4 5 4 5 4

4

5

B-2-13

B-2-15

B-2-15

B-2-16

B-2-17

B-2-19

B-2-20

B-2-18

B-2-22

B-2-21C-2-18

C-2-18C-2-20

C-2-19

C-2-21

C-2-22

C-2-23

C-2-26

C-2-25

C-2-24

EE

A/CA/C

EE

A/CA/C

EE

A/CA/C

GFI-TGFI-T

6

GFI-T

GFI-T

GFI-T

6 6

GFI-TGFI-T GFI-T GFI-T

GFI-T

6

6

GFI-T

GFI-T6

WAPE

WAPE

GFI-TGFI-T

R5

6

GFI-T

GFI-T6

6

GFI-T

GFI-T GFI-T

GFI-TWAPE

GFI-T

WAPE

6

6

+96"

GFI-T

6 6

WAPE

+60" +60"6

+96"GFI-T

6

GFI-T

WAPE

66

6

GFI-T

6

WAPE

6

GFI-T

GFI-T

GFI-T

6

6

GFI-T

GFI-T6

EE A/C

A/C

7

7

7

7

7

777

8

8

8

8

8

88

8

4

2

4444

444

2 2 2

22 2

2E

GFI-T

GFI-T

6

GFI-T

GFI-T

GFI-T

GFI-T

GFI-T GFI-TGFI-T GFI-T

GFI-T666

6

GFI-T

GFI-T

9 9 9 9

9

1. PROVIDE NEW TAMPER RESISTANT DEDICATED QUAD RECEPTACLE FOR LAPTOP CART CHARGING STATION.

2. NEW SURFACE MOUNTED PANELBOARD "B-2". CONTRACTOR TO UTILIZE, INTERCEPT, AND EXTEND ALL EXISTING ACTIVE FEEDER AND BRANCH CIRCUIT WIRING/CONDUIT OF SAME SIZE VIA NEW JUNCTION BOX OR PULL BOX AND CONNECT IT TO THE NEW PANELBOARD. CONTRACTOR TO PROVIDE MOUNTING ACCESSORIES AS REQUIRED.

3. NEW RECESSED PANELBOARD "C-2". CONTRACTOR TO UTILIZE, INTERCEPT, AND EXTEND ALL EXISTING ACTIVE FEEDER AND BRANCH CIRCUIT WIRING/CONDUIT OF SAME SIZE VIA NEW JUNCTION BOX OR PULL BOX AND CONNECT IT TO THE NEW PANELBOARD. PATCH WALL AND PAINT TO MATCH SURROUNDING WALL AS REQUIRED.

4. PROVIDE NEW BATTERY OPERATED WIRELESS CLOCK. COORDINATE WITH ARCHITECT FOR EXACT MOUNTING HEIGHT.

5. NEW LOCATION OF RELOCATED PA SPEAKER. EXTEND WIRING/CONDUIT TO NEW PA SPEAKER LOCATION, PROVIDE NEW AS REQUIRED.

6. PROVIDE NEW TAMPER RESISTANT RECEPTACLE WITH COVER PLATE AND RECONNECT TO EXISTING CIRCUIT.

7. CONTRACTOR TO COORDINATE IN FIELD FOR EXACT LOCATION OF RECEPTACLE AND DATA OUTLET SERVING THE INTERACTIVE SMARTBOARD TO AVOID CONFLICT WITH BASE PLATE. REFER TO ARCHITECTURAL DRAWING I4.6 DETAIL #1 AND # 2 FOR EXACT LOCATION AND MOUNTING HEIGHT.

8. CONTRACTOR TO FIELD TEST FUNCTIONLITY OF EXISTING TELEPHONE OUTLETS AND REPLACE AS REQUIRED. NEW TO MATCH EXISTING IN KIND MAKE AND TYPE.

9. INSTALL NEW PUBLIC ADDRESS SPEAKER AND WIRELESS CLOCK ON COVERPLATE PROVIDED DURING NEW CONSTRUCTION AT LOCATION OF DEMOLISHED SYNCHRONOUS CLOCK AND PUBLIC ADDRESS SPEAKER ASSEMBLY.

10. PROVIDE NEW BATTERY OPERATED WIRELESS CLOCK. INSTALL NEW WIRELESS CLOCK ON COVERPLATE PROVIDED DURING NEW CONSTRUCTION AT LOCATION OF DEMOLISHED SYNCHRONOUS CLOCK AND PUBLIC ADDRESS SPEAKER ASSEMBLY.

#

LOCATION NO. FILE NO.

DRAWN BY CHECKED BY

DRAWING NO.

1NO. DATE REVISION

www.philasd.org

SCHOOL & LOCATION

PROJECT TITLE

DRAWING TITLE

87654321

A

B

C

D

E

F

P H I L A D E L P H I A

(215) 400 - 4730 (215) 400 - 4731 (fax)

440 NORTH BROAD STREETPHILADELPHIA, PA 19130 - 4015

OFFICE OF CAPITAL PROGRAMS

T H E S C H O O L D I S T R I C T O F

SEAL:

CONRAD DELA CRUZSTATE AND LICENSE NO: 089048

Attn: Jessie HarderEmail: [email protected]

Phone: 717-458-0272Mechanicsburg, PA 17055401 E. Winding Hill RoadCRABTREE, ROHRBAUGH & ASSOCIATES

ARCHITECT

Attn: Deepak AjjimaneEmail: [email protected]

Phone: 667-309-6036Baltimore, MD 21202One South Street, Suite 1130SETTY

MEP ENGINEERS

2

3

4

5

6

7

8

9

10

ADDENDUM #12/27/19

B-041C OF 2018 / 19B-042C OF 2018 / 19

ORIGINAL DRAWING SIZE IS 30"x 42"; SCALE ENTITIES ACCORDINGLY IF REDUCED/ENLARGED SHEET OF 10

CRA NO. 3223

NS DAT

C:\Users\Nicole.serafin\Documents\3223_Electrical Link - Bryant_Nicole.Serafin.rvt2/27/2019 5:35:12 PM

ELECTRICAL OVERALLSECOND FLOOR PLAN -POWER NEW WORK

01/18/2019

E2.2

W.C. BRYANT SCHOOL

6001 CEDAR AVENUE,PHILADELPHIA, PA 19143

100% CONSTRUCTION

CLASSROOMMODERNIZATION

1/8" = 1'-0"E2.21 ELECTRICAL POWER OVERALL SECOND FLOOR PLAN - NEW WORK

7

1