the right choice for your application. level sensors from ifm. · 2017-04-24 · hydrostatic in...

28
The right choice for your application. Level sensors from ifm. Process sensors www.ifm.com/gb/level

Upload: others

Post on 27-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

The right choicefor your application.Level sensors from ifm.

Process sensors

www.ifm.com/gb/level

Page 2: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

2

Systems forlevel monitoring.The optimum solution forevery requirement.

Impedance spectros-copy in contact withthe medium

Alternative to vibratingforksSuppression of residuesand foam

Capacitive in contactwith the medium

For overflow preventionand leakage monitoring

Capacitivewithout contact

For the detectionthrough non-metallictank walls

Capacitive in contactwith the medium

For applicationson hydraulic andcoolant tanks

Guided wave radarin contact with themedium

For industrial andhygienic applications

Hydrostaticin contact withthe medium

For industrial andhygienic applicationson tanks and in free-flowing waterways

Ultrasonicwithout contact

For long distances anddifficult surfaces

Photoelectricwithout contact

For long distances

AccessoriesAdapters forlevel sensors inindustrial and hygienicapplications

Point level detection

Continuouslevel measurement

Even more choice?

More articles at

www.ifm.com

Page 3: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

3

4 - 5LMT, LMC –EHEDG, 3A, FDAEC1935, WHG*

ATEX–

6 - 7LI – WHG*–

8 - 9KG, KI, KQ – –

10 - 11LK, LT 73 WHG*

12 - 15LR 200 EHEDG, 3A, FDAEC1935, WHG*

16 - 21PG, PI,PA, PS, PN – EHEDG, 3A, FDA

EC1935, ATEX

22 - 23UGT 220

24 - 25O1D 980

26 - 27

Senso

r typ

e

Max

. mea

surin

g range [

cm]

Analogue o

utput

Switc

hing o

utput

Approva

ls

* German Federal Water Act

Page 4: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

4

Impedance spectroscopy.The alternative to tuningforks. Suppression ofresidues and foam.

Reliable detection:Suppression of residues,splashing water or foam.

Better than a tuning fork:No mechanical components, fullycompatible regarding installationand function.

Immediately ready for use:Factory settings for the mostcommon media.

Adaptable using IO-Link:Adaptation to and differentiationof media configurable.

More transparency:Read process values to optimisethe application.

Hygienic design:High-grade stainless steelhousing with PEEK sensor tip.Versions for industrial anhygienic applications.

Type LMClevel sensors

Flexible mountingthanks to orienta-tion-independentinstallation.

Shock and vibra-tion resistant ina robust stainlesssteel housing

Complementaryswitching outputs.

A thread at theback permitsvariable insertiondepths.

Application area Water Oil

G 1/2 10 LMC110LMC100

G 1/2 21 LMC410LMC400

1/2 NPT 34 LMC510LMC500

1/2 NPT 40 LMC502

Point level detection in contact with the medium

Processconnection

Insertiondepth[mm]

Order no. Order no.

For adapterssee pages26 - 27

Page 5: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

5

Type LMTlevel sensors

Flexible mountingthanks to orienta-tion-independentinstallation.

Shock and vibra-tion resistant ina robust stainlesssteel housing.

Hygienic approvalsEHEDG, 3A andFDA.

Versions availableas overflow pre-vention to WHG*.

Complementaryswitching outputs.

For hygienic areasand viscous media

For industrialapplications

Approvals

Preset to aqueous media

WHG* ATEX

G 1/2 11 LMT191

G 1/2 38 LMT192

G 1/2 153 LMT194

G 1/2 253 LMT195

Processconnection

Insertiondepth[mm]

Order no.

Hygienic

LMT100

LMT102

LMT104

Preset to oils, fats, powder

G 1/2 11 LMT01A

G 1/2 153 LMT03A

G 1/2 253 LMT04A

LMT110

Preset to sugary media

G 1/2 11 LMT121

LMT105

G 3/4 28 LMT292

G 1 38 LMT392

LMT202

LMT302

Order no. Order no.

Manholemonitoring

Fullmonitoring

Emptymonitoring

Run-dryprotection

Type LMCwith a threadat the back.

* German Federal Water Act

Page 6: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

6

Capacitive.For overflow preventionand leakage monitoring. Ready in no time:

Easy mounting adjustment.

Flexible:Normally closed / normally openprogrammable.

Clear:Clearly visible indication of theswitch points.

Variable use:Insertion depths of 132 to 737 mm.

Certified:Approval as overflow preventionor leakage sensor to WHG*.

Point level detection in contact with the medium

Type LIpoint level sensors

Optimised for usein hydraulic oilsand coolants.

Modular mountingconcept for flexibleuse.

It only takes onepush of a buttonto adjust andset the outputfunc tion.

Rod length

[mm]

Watertemperature

[°C]

Oiltemperature

[°C]

Order no.

1 switching output, normally closed / normally open programmable

1 switching output, normally closed

Overflow prevention to WHG*

Leakage sensor to WHG*

1) in connection with climatic tube see accessories page 27

132 0...35 (0...65)1) 0...65 LI5141

273 0...35 (0...65)1) 0...65 LI5142

481 0...35 (0...65)1) 0...65 LI5143

737 0...35 (0...65)1) 0...65 LI5144

132 0...35 0...65 LI2141

273 0...35 0...65 LI2142

481 0...35 0...65 LI2143

132 0...35 0...65 LI2241

273 0...35 0...65 LI2242

481 0...35 0...65 LI2243

* German Federal Water Act

Page 7: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

7

For industrialapplications

Order now?

www.ifm.com

For adapterssee pages26 - 27

Page 8: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

Capacitive.For the detectionthrough non-metallictank walls.

Convenient:Many functions such as binaryswitching output, timer functionsas output, damping function aswell as normally closed / normallyopen and window function.

Communicative:Process values, parameter settingdata and diagnostic informationcan be transferred and evaluatedvia IO-Link.

Simple:Parameter setting via IO-Linkbefore installation, as an alterna-tive also via pushbuttons on thesensor.

Repeatable:Simple parameter setting of manysensors via “copy & paste” inthe LR DEVICE software or viaa memory plug.

Perfect:Ingeniously simple switch pointsetting thanks to the LED display.

Point level detection without contact

8

Type KG / KIpoint level sensors

Capacitive sensorsin cylindrical M18or M30 housing.

Protection ratingIP 65 to IP 69K.

High mediumtemperature upto 110 °C.

EMC resistance upto 30,000 V.

12-digit display foroptimum switchpoint setting (KG /KI6000).

Sensing range

[mm]

Connection Setting Order no. Order no. Order no.

DC PNP normallyclosed

normallyopen

program-mable

M18 housing, plastic

0.5...40 nf M12 connector display KG6000

8 nf cable teach button KG50691)

12 nf M12 connector teach button KG5066

0.5...30 nf cable potentiometer KG5303KG5301

M30 housing, plastic

0.5...40 nf M12 connector display KI6000

20 nf M12 connector teach button KI5083

M30 housing, metal

8 f M12 connector teach button KI5085

15 nf M12 connector teach button KI5087

0.5...40 nf cable potentiometer KI5303KI5301

0.5...40 nf M12 connector potentiometer KI5309KI5307

0.5...30 nf M12 connector potentiometer KG5309KG5307

1) housing white PPf: flush installation nf: non-flush installation

Page 9: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

For industrialapplications

9

Sensing range

[mm]

Connection Order no.

DC PNP

Type KQ pointlevel sensors

Capacitive sensorsin small plastic rect -angular housing.

Easy installationwith mountingadapters andfixing straps.

12 nf cable 2 m KQ6002

12 nf cable plugM8 KQ6004

12 nf cable plugM12 KQ6005

12 nf cable 2 m KQ5100

12 nf cable plugM12 KQ5101

12 nf cable plugM8 KQ5102

12-digit display foroptimum switchpoint setting(KG / KI6000).

Page 10: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

Capacitive.For applicationson hydraulic andcoolant tanks.

Professional:For industrial applications inwater-based or oil-basedmedia.

Versatile:Versions with 2 or 4 switchingoutputs or analogue output4...20 mA / 0...10 V.

Safe:Type LK12 with approval as over-flow prevention to WHG*.

Combined:Type LT for level and temperaturemonitoring.

Flexible:Variable insertion depths thanksto clamp fitting.

Continuous level measurementin contact with the medium

10

Type LKlevel sensors

Display and hand-ling directly onthe unit or viaIO-Link1).

As an option withanalogue outputor up to fourswitching outputs.

Suitable for oiltemperatures upto 70 °C.

Versions to WHG*available.

Rod length

[mm]

Type Order no.

2 switching outputs

1) IO-Link availablefrom 3rd quarter2017

264 LK1022

472 LK1023

728 LK1024

1 switching output and 1 analogue output 4...20 mA / 0...10 V

264 LK3122

472 LK3123

728 LK3124

4 switching outputs

264 LK8122

472 LK8123

728 LK8124

264

Automatic medium detection

LK7022

472 LK7023

728 LK7024

264 LK1222

728 LK1224

472 WHG* LK1223

* German Federal Water Act

Page 11: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

For industrialapplications

11

Type LTlevel sensors

Display and hand-ling directly onthe unit or viaIO-Link1).

Suitable forwater-based andoil-based media.

Suitable for oiltemperatures upto 70 °C.

For level and tem-perature.

Rod length

[mm]

Type Order no.

4 switching outputs for level and temperature

For adapterssee pages26 - 27

264 2 switching outputs level

2 switching outputs temperature 2)

LT8022

472 LT8023

728 LT8024

1 analogue output, 1 switching output

264 1 analogue output level 2)

1 switching output temperature 2)

LT3022

472 LT3023

728 LT3024

2) level / temperature selectable

1) IO-Link availablefrom 3rd quarter2017

Page 12: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

Guided wave radar.For industrial and hygienicapplications. Versatile:

Modular sensor concept, flexiblein use.

Variable:Rods can be cut to size as required.

Reliable:Measuring principle independentof temperature influences.

Optional outputs:Versions with two or four switching outputs or analogueoutput 4...20 mA / 0...10 V.

Selectable:Designs with and without display.

12

Type LRlevel sensors

Display and hand-ling on the unit orvia IO-Link.

As an option withanalogue outputor up to fourswitching outputs.

Rod lengths of10...200 cm select -able.

Versions to WHG*available.

Process connection Order no.

2 switching outputs or 1 switching outputand 1 analogue output 4...20 mA

Process connection Order no.

2 switching outputs

Process connection Order no.

1 analogue output 4...20 mA or 0...10 V

1 switching outputand 1 analogue output 4...20 mA or 0...10 V

LR type leveltransmitter

For industrialapplications.

Analogue outputscalable4...20 mA / 0...10 V.

Protection ratingIP 69K.

Easily adjustablevia IO-Link.

4 switching outputs

4 switching outputs / WHG*

1) only in connection with rod and coaxial pipe,see page 14

G 3/4 male LR2050

3/4" NPT LR2350

G 3/4 male LR3000

3/4" NPT LR3300

G 3/4 male LR7000

3/4" NPT LR7300

G 3/4 male LR8000

G 3/4 male LR80101)

3/4" NPT LR8300

G 3/4 male LR9020

* German Federal Water Act

Continuous level measurementin contact with the medium

Page 13: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

13

For hygienic areasand viscous media

For industrialapplications

Process connection Order no.

2 switching outputs or 1 switching outputand 1 analogue output 4...20 mA

Type LR27hygienic levelsensor

Display and hand-ling on the unit orvia IO-Link.

Medium tempera-ture -40...150 °C.

Pressure-resistantup to 40 bar.

Rod lengths of15...200 cm select -able.

For rods andcoaxial pipes seepages 14 - 15

For adapterssee pages26 - 27

Aseptoflex Vario G1 LR2750

Page 14: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

G 3/4

G 3/4

Level sensors3/4" NPTType LR3300Type LR7300Type LR8300Type LR2350

150 E43225

Length[mm]

Order no.

210 E43351

240 E43203

265 E43352

300 E43226

450 E43204

500 E43227

Rods for LR levelsensors with 3/4"NPT or G 3/4 male,industrial applica-tions

Materialhigh-gradestainless steel(1.4404 / 316L)

1) only in connectionwith rod and coaxialpipe

Level sensorsG 3/4 maleType LR2050Type LR3000Type LR7000Type LR8000Type LR80101)

Type LR9020

150 E43230

Processconnection

Length[mm]

Order no.

210 E43354

240 E43211

265 E43355

300 E43228

450 E43212

500 E43229

700 E43213

800 E43336

1000 E43214

1200 E43215

1400 E43216

1600 E43217

450, without holes E43320

2000 E433562)

700, slotted E43333

1200, slotted E43334

2) only for sensor type LR2050

Coaxial pipes forLR level sensorswith G 3/4 male,industrial applica-tions

Materialstainless steel(1.4301 / 304)

Guided wave radar.Rods and coaxial pipes.

14

Continuous level measurementin contact with the medium

Page 15: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

700 E43205

Length[mm]

Order no.

800 E43337

1000 E43207

1200 E43208

1400 E43209

1600 E43210

2000 E433532)

2) only for sensor type LR2050

3/4" NPT

240 E43377

Processconnection

Length[mm]

Order no.

450 E43218

700 E43219

1000 E43220

1200 E43223

1400 E43224

1600 E43221

2000 E43378

150 E43345

Length[mm]

Order no.

300 E43346

500 E43340

700 E43347

1000 E43341

1500 E43348

2000 E43342

Hygieniclevel sensortype LR2750

Rods forlevel sensorLR2750, hygienic

Materialhigh-gradestainless steel(1.4404 / 316L)

For a wide selection of

more accessories visit

www.ifm.com

For adapterssee pages26 - 27

For hygienic areasand viscous media

For industrialapplications

15

Page 16: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

Hydrostatic.For industrial applicationson tanks and infree-flowing waterways.

Robust:Overload-protected measuringprinciples with a good long-termstability.

Compact:Pressure transmitters withoutdisplay and with analogueoutput.

Precise:Ceramic-capacitive and piezo-resistive measuring cells.

16

Type PApressure sensors

2-wire pressuretransmitters.

Ceramic-capacitivemeasuring cell. G 1/4 female 0...1000

Process connection Measuring rangeRelative pressure

[mbar]

Analogue output 4...20 mA

Order no.

PA3027

G 1/4 female 0...250 PA3028

G 1/4 female 0...1000

Analogue output 0...10 V

PA9027

G 1/4 female 0...250 PA9028

G 1/4 male 0...250 PA3528

G 1/4 male 0...100 PA3589

Order now?

www.ifm.com

Continuous level measurementin contact with the medium

Page 17: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

For industrialapplications

17

For adapterssee pages26 - 27

Type PSsubmersiblepressure trans-mitters

PUR or FEP cablefor high resistanceto media.

Version withATEX approvalfor group I cat. M1and group II cat.1G and 1D.

Pressure compen-sation via inter-nally vented cable.

0...1000 PUR, 30 PS3617

Measuring rangeRelative pressure

[mbar]

Cable

[m]

Order no.

For standard applications, CE approval

0...1000 PUR, 15 PS3417

0...1000 FEP, 30 PS4607

For high resistance to media, CE approval

0...1000 FEP, 15 PS4417

0...600 FEP, 20 PS4506

0...1000 FEP, 15 PS317A

For hazardous areas, CE, Ex, GL approvals

0...600 FEP, 10 PS307A

0...250 FEP, 5 PS308A

0...600 FEP, 10 PS4407

0...250 FEP, 10 PS4408

0...250 FEP, 5 PS4208

0...600 PUR, 30 PS3607

0...600 PUR, 15 PS3427

0...600 PUR, 10 PS3407

0...250 PUR, 5 PS3208

Page 18: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

Hydrostatic.For industrial applicationson tanks and infree-flowing waterways.

Robust:Overload-protected measuringprinciples with a good long-termstability.

Quick setting:Easy to use via 3 pushbuttons(type PN).

Clear:Large pointer display with LEDring (type PG).

Precise:Ceramic-capacitive and piezo-resistive measuring cells.

18

Processconnection

Factory settingMeasuring rangeRelative pressure

[mbar]

Factory settingMeasuring rangeRelative pressure

[mbar]

Order no.

2 switching outputs 1 switching output and 1 analogueoutput 4...20 mA / 0...10 V

Order no.

G 1/4 female 0...1000 0...1000 PN3097PN7097

G 1/4 male 0...1000 0...1000 PN3597PN7597

2 switching outputs or 1 switching output and 1 analogue output 4...20 mA / 0...10 V, scalable

G 1/4 female 0...1000 0...250 PN2098PN2097

G 1/4 male 0...1000 0...250 PN2598PN2597

G 1/4 female -500...500 PN2169

G 1/4 male -500...500 PN2569

PN typepressure sensors

Programmable2-colour display,clearly visibleswitch-point LEDs.

Rotatable processconnection.

Operation via3 raised push-buttons.

IO-Link.

Continuous level measurementin contact with the medium

Page 19: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

For industrialapplications

19

Type PGpressure sensors

Optimum legibilitydue to theelectronic pointerdisplay.

Rotatable display.

Display of thetrend or of theminimum andmaximum values.

Processconnection

Factory settingMeasuring rangeRelative pressure

[mbar]

1 switching output and 1 analogue output 4...20 mA / 20...4 mA, scalable

Order no.

G 1/2 male 0...1000 PG2457

G 1/2 male 0...250 PG2458

G 1/2 male 0...100 PG2489

For adapterssee pages26 - 27

Page 20: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

Hydrostatic.For hygienic applicationson large tanks. Hygienic:

Ingress resistance, materials andapprovals comply with hygienicrequirements.

Robust:Overload-resistant ceramic-capacitive measuring cells withlong-term stability.

Versatile:Variable process connections.

Precise:High overall accuracy (0.2 %).

Suitable for CIP/SIP:High temperature resistanceand electronic temperaturecompensation.

20

0...100 PG2789 PG2889

0...250 PG2798 PG2898

0...1000 PG2797 PG2897

-1000...1000 PG2799 PG2899

Type PGpressure sensors

Optimum legibilitydue to theelectronic pointerdisplay.

Rotatable display.

Display of thetrend or of theminimum andmaximum values.

Factory settingMeasuring rangeRelative pressure

[mbar]

Process connection

1 switching outputand 1 analogue output 4...20 mA / 20...4 mA, scalable

G1 male Aseptoflex VarioOrder no.

G1 male sealing coneOrder no.

0...1600 PM1717 PM1617

-1000...1000 PM1709 PM1609

0...1000 PM1707 PM1607

0...100 PM1789 PM1689

0...250 PM1708 PM1608

Type PM pressuretransmitters

Programmableanalogue output.

Free factorycertificate fordownload.

Accuracy 0.2 %.

IO-Link.

Factory settingMeasuring rangeRelative pressure

[mbar]

Process connection

Analogue output 4...20 mA, scalable

G1 male Aseptoflex VarioOrder no.

G1 male sealing coneOrder no.

available from September 2017

Continuous level measurementin contact with the medium

Page 21: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

21

For hygienic areasand viscous media

For adapterssee pages26 - 27

Type PIpressure sensors

Programmableanalogue outputin 2-wire opera-tion.

Additionalswitching outputin 3/4-wire opera-tion.

IO-Link.

0...100 PI2789 PI2889

0...250 PI2798 PI2898

0...1000 PI2797 PI2897

-1000...1000 PI2799 PI2899

0...1600 PI2717 PI2817

Factory settingMeasuring rangeRelative pressure

[mbar]

Process connection

1 switching outputand 1 analogue output 4...20 mA / 20...4 mA

G1 male Aseptoflex VarioOrder no.

G1 male sealing coneOrder no.

Page 22: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

Ultrasonic.For long distances anddifficult surfaces. Precise:

Precise and continuous levelmeasurement, e.g. of bulkmaterials.

Robust:High-grade stainless steel hous -ing for demanding applications.

Simple:Setting via teach button, wireteach or IO-Link.

Flexible:Normally closed / normally openprogrammable.

Versatile:Versions with two switching out-puts or switching and analogueoutputs 4...20 mA / 0...10 V.

Continuous level measurement without contact

22

Type UGTultrasonic sensors

Ultrasonic sensorsin cylindrical M18housing.

60 300

Housing length

[mm]

Max. range[mm]

Setting via

Switching output PNP NPN

Order no. Order no.

UGT500

60 800 UGT503

60 1200

wire

wire

wire UGT506

UGT521

UGT522

UGT523

60 300

Analogue output 4...20 mA 0...10 V

UGT501

60 800 UGT504

60 1200

wire

wire

wire UGT507

UGT502

UGT505

UGT508

98 1600

2 switching outputs PNP NPN

UGT509

98 2200 UGT512

button, IO-Link1)

button, IO-Link1)

UGT515

UGT518

98 1600

1 switching output PNP, 1 analogue output 4...20 mA 0...10 V

UGT510

98 2200 UGT513

button, IO-Link

button, IO-Link

UGT511

UGT514

98 1600

1 switching output NPN, 1 analogue output 4...20 mA 0...10 V

UGT516

98 2200 UGT519

button

button

UGT517

UGT520

1) IO-Link not for NPN version

Page 23: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

23

For industrialapplications

300

Max.range[mm]

Setting via

1 switching output PNP,1 analogue output

4...20 mA 0...10 V

Order no. Order no.

UGT580

800 UGT582

1200

button

button

button UGT584

UGT581

UGT583

UGT585

300

1 switching output NPN,1 analogue output

4...20 mA 0...10 V

UGT586

800 UGT588

1200

button

button

button UGT590

UGT587

UGT589

UGT591

Type UGTultrasonic sensors

Ultrasonic sensorsin M18 Cubehousing.

Versions in plastic at

www.ifm.com

Page 24: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

Photoelectric.For long distances.

Longest distance:Photoelectric level detectionof bulk materials and non-transparent liquids, for levelsup to 9.8 m.

Convenient:Scalable detection range withwindow function.

Reliable detection:Can be used in applicationsneeding background suppression.

Flexible mounting:Extensive range of fixingcomponents.

Continuous level measurement without contact

24

0.2...9.8 M12 connector < 15 x 15

Measuring range

[m]

Connection Light spot diameter

[mm]

2 switching outputs or 1 switching outputand 1 analogue output 4...20 mA / 0...10 V, scalable

Type O1Dphotoelectricdistance sensorwith time of flightmeasurement

Resistant to extra-neous light up to100,000 lux.

2 switching out-puts, one outputcan be configuredas analogue out-put.

4-digit alpha-numeric display.

Order no.

O1D300

Order now?

www.ifm.com

Page 25: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

For industrialapplications

25

Accessories No. Description Order no.

Mounting brackethigh-grade stainless steel (1.4404 / 316 L) E21120

Clamp mounting setfor rod mount Ø 12 mm E2D101

Mounting adapterwith process connection G1 male E21224

Mounting rod, 100 mm, Ø 12 mm,M10 thread, stainless steel E20938

Mounting rod, 200 mm, Ø 12 mm,M10 thread, stainless steel E20940

Cube for mounting on an aluminium profile,M10 thread, stainless steel E20951

Mounting accessories

Protective cover, glass window E21171

Device protection

Cooling box E21248

Protective cover, PMMA window E21133

1

8

7

654

3

2

1

2

3

4

5

6

7

8

Page 26: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

12

26

Accessories.Adapters for level sensorsin industrial and hygienicapplications.

Adapters G 1/2for type LMT

2

45

6

7

8

9

11

E43315

E43309

E43310

E43311

E43312

Clamp 1 - 1.5"

Process connectionNo. Order no. Order no.with leakage port

E33401

Mounting adapters for industrial and hygienic applications

Clamp 2" E33402

Hygienic pipe fitting, DN25 E43304

Hygienic pipe fitting DN40 E43305

Varivent type F DN25, D = 50 E43306

Varivent type N DN40...150, D = 68 E43307

Adapter G 1 E43303

Adapter G 3/4 E43302

Pipe fitting, DN25 SMS E33430

E33444Pipe fitting DN50 SMS –

Sealing plug G 1/2 E43308

Adapter 3/4" NPT E43313

Collar G 1/2 Ø 45 mm E30056

Welding adapters for industrial and hygienic applications

Ball G 1/2 Ø 35 mm E30055

Long version G 1/2 Ø 50 mm E43319

Welding mandrel G 1/2 E43314

For tanks G 1/2 Ø 30 mm E43300

For pipes G 1/2 Ø 29 mm E43301

T-piece DN25 E43316

T-pieces for industrial and hygienic applications

T-piece DN40 E43317

T-piece DN50 E43318

Clamp adapter for type LMT1041) E43349

Variable clamp adapters

Clamp adapter for type LMT1051) E43322

1) only in connection with G 1/2 female adapter

3

10

For a wide selection ofmore accessories visitwww.ifm.com

No. Description Order no.

G 1/2 E43375

Welding adapter

Adapter G 1/2for type LMC

25

1

2

3

4

4

5

6

7

9

10

8

8

25

12

11

Page 27: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

27

For hygienic areasand viscous media

For industrialapplications

AdaptersG1 male /Aseptoflex Variofor typesPG, PI, LR

13

14

15

16

17

Flange DRD, D = 65 E33242

E33228

E33229

Varivent type F DN25, D = 50 E33221

Varivent type N DN40...150, D = 68 E33222

E33208

E33209

E33304

Clamp 1 - 1.5"

Process connectionNo. Order no. Order no. with leakage port

E33201

Mounting adapters for industrial and hygienic applications

Clamp 2" E33202

Hygienic pipe fitting DN32 E33211

Hygienic pipe fitting DN50 E33213

Hygienic pipe fitting DN40 E33212

Universal process adapter Rd52 E33340

Pipe fitting DIN 11864-1 A-BS –

E30130

Welding adapter Ø 50 mm E30122

Welding adapters for industrial and hygienic applications

Sealing plug E30128

18

19

20

21

Adaptersfor types LI, LK, LT

No. Description Order no.

Mounting clamp Ø 16 mm E43000

Welding adapter Ø 50 mm E43002

Mounting adapters

Climatic tube, 264 mm long E43100

Device protection

Climatic tube, 728 mm long E43102

Climatic tube, 472 mm long E43101

Mounting adapter G 3 E43003

Mounting adapter G 1 E43004

Mounting adapter 3/4" NPT E43012

Climatic tube, 132 mm long E43103

Want to find the

suitable connector?

www.ifm.com

No. Type Order no.

Flange plate 73 - 90 / G 3/4 E43201

Launching plate G 3/4 for type LRfor installation in plastic tanks E43380

Launching plate 3/4" NPT for type LRfor installation in plastic tanks E43381

Flange plate 65 - 80 / G 3/4 E43202

Mounting adapters

Protective cover E43910

Device protection

Adaptersfor types LR, LK

22

24

23

16

15

13

14

17

18

21

20

22

23

24

19

Page 28: The right choice for your application. Level sensors from ifm. · 2017-04-24 · Hydrostatic in contact with the medium For industrial and hygienic applications ... For industrial

ifm a

rtic

le n

o. 7

8002

299

· We

rese

rve

the

right

to

mak

e te

chni

cal a

ltera

tions

with

out

prio

r no

tice.

· Pr

inte

d in

Ger

man

y on

non

-chl

orin

e bl

each

ed p

aper

. 03

/17

Visit our website:www.ifm.com

Position sensors

Sensors formotion control

Industrial imaging

Safety technology

Process sensors

Systems formobile machines

Industrialcommunication

Condition monitoringsystems

Connectiontechnology

Software

Power supplies

AccessoriesIO-Link

years

W

ARRANTY

on ifm products

Identification systems

ifm electronic gmbh

Friedrichstraße 145128 EssenTel. +49 / 201 / 24 22-0Fax +49 / 201 / 24 22-1200E-mail [email protected]