the right choice for your application. level sensors from ifm. · 2017-04-24 · hydrostatic in...
TRANSCRIPT
The right choicefor your application.Level sensors from ifm.
Process sensors
www.ifm.com/gb/level
2
Systems forlevel monitoring.The optimum solution forevery requirement.
Impedance spectros-copy in contact withthe medium
Alternative to vibratingforksSuppression of residuesand foam
Capacitive in contactwith the medium
For overflow preventionand leakage monitoring
Capacitivewithout contact
For the detectionthrough non-metallictank walls
Capacitive in contactwith the medium
For applicationson hydraulic andcoolant tanks
Guided wave radarin contact with themedium
For industrial andhygienic applications
Hydrostaticin contact withthe medium
For industrial andhygienic applicationson tanks and in free-flowing waterways
Ultrasonicwithout contact
For long distances anddifficult surfaces
Photoelectricwithout contact
For long distances
AccessoriesAdapters forlevel sensors inindustrial and hygienicapplications
Point level detection
Continuouslevel measurement
Even more choice?
More articles at
www.ifm.com
3
4 - 5LMT, LMC –EHEDG, 3A, FDAEC1935, WHG*
ATEX–
6 - 7LI – WHG*–
8 - 9KG, KI, KQ – –
10 - 11LK, LT 73 WHG*
12 - 15LR 200 EHEDG, 3A, FDAEC1935, WHG*
16 - 21PG, PI,PA, PS, PN – EHEDG, 3A, FDA
EC1935, ATEX
22 - 23UGT 220
24 - 25O1D 980
26 - 27
Senso
r typ
e
Max
. mea
surin
g range [
cm]
Analogue o
utput
Switc
hing o
utput
Approva
ls
* German Federal Water Act
4
Impedance spectroscopy.The alternative to tuningforks. Suppression ofresidues and foam.
Reliable detection:Suppression of residues,splashing water or foam.
Better than a tuning fork:No mechanical components, fullycompatible regarding installationand function.
Immediately ready for use:Factory settings for the mostcommon media.
Adaptable using IO-Link:Adaptation to and differentiationof media configurable.
More transparency:Read process values to optimisethe application.
Hygienic design:High-grade stainless steelhousing with PEEK sensor tip.Versions for industrial anhygienic applications.
Type LMClevel sensors
Flexible mountingthanks to orienta-tion-independentinstallation.
Shock and vibra-tion resistant ina robust stainlesssteel housing
Complementaryswitching outputs.
A thread at theback permitsvariable insertiondepths.
Application area Water Oil
G 1/2 10 LMC110LMC100
G 1/2 21 LMC410LMC400
1/2 NPT 34 LMC510LMC500
1/2 NPT 40 LMC502
Point level detection in contact with the medium
Processconnection
Insertiondepth[mm]
Order no. Order no.
For adapterssee pages26 - 27
5
Type LMTlevel sensors
Flexible mountingthanks to orienta-tion-independentinstallation.
Shock and vibra-tion resistant ina robust stainlesssteel housing.
Hygienic approvalsEHEDG, 3A andFDA.
Versions availableas overflow pre-vention to WHG*.
Complementaryswitching outputs.
For hygienic areasand viscous media
For industrialapplications
Approvals
Preset to aqueous media
WHG* ATEX
G 1/2 11 LMT191
G 1/2 38 LMT192
G 1/2 153 LMT194
G 1/2 253 LMT195
Processconnection
Insertiondepth[mm]
Order no.
Hygienic
LMT100
LMT102
LMT104
Preset to oils, fats, powder
G 1/2 11 LMT01A
G 1/2 153 LMT03A
G 1/2 253 LMT04A
LMT110
Preset to sugary media
G 1/2 11 LMT121
LMT105
G 3/4 28 LMT292
G 1 38 LMT392
LMT202
LMT302
Order no. Order no.
Manholemonitoring
Fullmonitoring
Emptymonitoring
Run-dryprotection
Type LMCwith a threadat the back.
* German Federal Water Act
6
Capacitive.For overflow preventionand leakage monitoring. Ready in no time:
Easy mounting adjustment.
Flexible:Normally closed / normally openprogrammable.
Clear:Clearly visible indication of theswitch points.
Variable use:Insertion depths of 132 to 737 mm.
Certified:Approval as overflow preventionor leakage sensor to WHG*.
Point level detection in contact with the medium
Type LIpoint level sensors
Optimised for usein hydraulic oilsand coolants.
Modular mountingconcept for flexibleuse.
It only takes onepush of a buttonto adjust andset the outputfunc tion.
Rod length
[mm]
Watertemperature
[°C]
Oiltemperature
[°C]
Order no.
1 switching output, normally closed / normally open programmable
1 switching output, normally closed
Overflow prevention to WHG*
Leakage sensor to WHG*
1) in connection with climatic tube see accessories page 27
132 0...35 (0...65)1) 0...65 LI5141
273 0...35 (0...65)1) 0...65 LI5142
481 0...35 (0...65)1) 0...65 LI5143
737 0...35 (0...65)1) 0...65 LI5144
132 0...35 0...65 LI2141
273 0...35 0...65 LI2142
481 0...35 0...65 LI2143
132 0...35 0...65 LI2241
273 0...35 0...65 LI2242
481 0...35 0...65 LI2243
* German Federal Water Act
7
For industrialapplications
Order now?
www.ifm.com
For adapterssee pages26 - 27
Capacitive.For the detectionthrough non-metallictank walls.
Convenient:Many functions such as binaryswitching output, timer functionsas output, damping function aswell as normally closed / normallyopen and window function.
Communicative:Process values, parameter settingdata and diagnostic informationcan be transferred and evaluatedvia IO-Link.
Simple:Parameter setting via IO-Linkbefore installation, as an alterna-tive also via pushbuttons on thesensor.
Repeatable:Simple parameter setting of manysensors via “copy & paste” inthe LR DEVICE software or viaa memory plug.
Perfect:Ingeniously simple switch pointsetting thanks to the LED display.
Point level detection without contact
8
Type KG / KIpoint level sensors
Capacitive sensorsin cylindrical M18or M30 housing.
Protection ratingIP 65 to IP 69K.
High mediumtemperature upto 110 °C.
EMC resistance upto 30,000 V.
12-digit display foroptimum switchpoint setting (KG /KI6000).
Sensing range
[mm]
Connection Setting Order no. Order no. Order no.
DC PNP normallyclosed
normallyopen
program-mable
M18 housing, plastic
0.5...40 nf M12 connector display KG6000
8 nf cable teach button KG50691)
12 nf M12 connector teach button KG5066
0.5...30 nf cable potentiometer KG5303KG5301
M30 housing, plastic
0.5...40 nf M12 connector display KI6000
20 nf M12 connector teach button KI5083
M30 housing, metal
8 f M12 connector teach button KI5085
15 nf M12 connector teach button KI5087
0.5...40 nf cable potentiometer KI5303KI5301
0.5...40 nf M12 connector potentiometer KI5309KI5307
0.5...30 nf M12 connector potentiometer KG5309KG5307
1) housing white PPf: flush installation nf: non-flush installation
For industrialapplications
9
Sensing range
[mm]
Connection Order no.
DC PNP
Type KQ pointlevel sensors
Capacitive sensorsin small plastic rect -angular housing.
Easy installationwith mountingadapters andfixing straps.
12 nf cable 2 m KQ6002
12 nf cable plugM8 KQ6004
12 nf cable plugM12 KQ6005
12 nf cable 2 m KQ5100
12 nf cable plugM12 KQ5101
12 nf cable plugM8 KQ5102
12-digit display foroptimum switchpoint setting(KG / KI6000).
Capacitive.For applicationson hydraulic andcoolant tanks.
Professional:For industrial applications inwater-based or oil-basedmedia.
Versatile:Versions with 2 or 4 switchingoutputs or analogue output4...20 mA / 0...10 V.
Safe:Type LK12 with approval as over-flow prevention to WHG*.
Combined:Type LT for level and temperaturemonitoring.
Flexible:Variable insertion depths thanksto clamp fitting.
Continuous level measurementin contact with the medium
10
Type LKlevel sensors
Display and hand-ling directly onthe unit or viaIO-Link1).
As an option withanalogue outputor up to fourswitching outputs.
Suitable for oiltemperatures upto 70 °C.
Versions to WHG*available.
Rod length
[mm]
Type Order no.
2 switching outputs
1) IO-Link availablefrom 3rd quarter2017
264 LK1022
472 LK1023
728 LK1024
1 switching output and 1 analogue output 4...20 mA / 0...10 V
264 LK3122
472 LK3123
728 LK3124
4 switching outputs
264 LK8122
472 LK8123
728 LK8124
264
Automatic medium detection
LK7022
472 LK7023
728 LK7024
264 LK1222
728 LK1224
472 WHG* LK1223
* German Federal Water Act
For industrialapplications
11
Type LTlevel sensors
Display and hand-ling directly onthe unit or viaIO-Link1).
Suitable forwater-based andoil-based media.
Suitable for oiltemperatures upto 70 °C.
For level and tem-perature.
Rod length
[mm]
Type Order no.
4 switching outputs for level and temperature
For adapterssee pages26 - 27
264 2 switching outputs level
2 switching outputs temperature 2)
LT8022
472 LT8023
728 LT8024
1 analogue output, 1 switching output
264 1 analogue output level 2)
1 switching output temperature 2)
LT3022
472 LT3023
728 LT3024
2) level / temperature selectable
1) IO-Link availablefrom 3rd quarter2017
Guided wave radar.For industrial and hygienicapplications. Versatile:
Modular sensor concept, flexiblein use.
Variable:Rods can be cut to size as required.
Reliable:Measuring principle independentof temperature influences.
Optional outputs:Versions with two or four switching outputs or analogueoutput 4...20 mA / 0...10 V.
Selectable:Designs with and without display.
12
Type LRlevel sensors
Display and hand-ling on the unit orvia IO-Link.
As an option withanalogue outputor up to fourswitching outputs.
Rod lengths of10...200 cm select -able.
Versions to WHG*available.
Process connection Order no.
2 switching outputs or 1 switching outputand 1 analogue output 4...20 mA
Process connection Order no.
2 switching outputs
Process connection Order no.
1 analogue output 4...20 mA or 0...10 V
1 switching outputand 1 analogue output 4...20 mA or 0...10 V
LR type leveltransmitter
For industrialapplications.
Analogue outputscalable4...20 mA / 0...10 V.
Protection ratingIP 69K.
Easily adjustablevia IO-Link.
4 switching outputs
4 switching outputs / WHG*
1) only in connection with rod and coaxial pipe,see page 14
G 3/4 male LR2050
3/4" NPT LR2350
G 3/4 male LR3000
3/4" NPT LR3300
G 3/4 male LR7000
3/4" NPT LR7300
G 3/4 male LR8000
G 3/4 male LR80101)
3/4" NPT LR8300
G 3/4 male LR9020
* German Federal Water Act
Continuous level measurementin contact with the medium
13
For hygienic areasand viscous media
For industrialapplications
Process connection Order no.
2 switching outputs or 1 switching outputand 1 analogue output 4...20 mA
Type LR27hygienic levelsensor
Display and hand-ling on the unit orvia IO-Link.
Medium tempera-ture -40...150 °C.
Pressure-resistantup to 40 bar.
Rod lengths of15...200 cm select -able.
For rods andcoaxial pipes seepages 14 - 15
For adapterssee pages26 - 27
Aseptoflex Vario G1 LR2750
G 3/4
G 3/4
Level sensors3/4" NPTType LR3300Type LR7300Type LR8300Type LR2350
150 E43225
Length[mm]
Order no.
210 E43351
240 E43203
265 E43352
300 E43226
450 E43204
500 E43227
Rods for LR levelsensors with 3/4"NPT or G 3/4 male,industrial applica-tions
Materialhigh-gradestainless steel(1.4404 / 316L)
1) only in connectionwith rod and coaxialpipe
Level sensorsG 3/4 maleType LR2050Type LR3000Type LR7000Type LR8000Type LR80101)
Type LR9020
150 E43230
Processconnection
Length[mm]
Order no.
210 E43354
240 E43211
265 E43355
300 E43228
450 E43212
500 E43229
700 E43213
800 E43336
1000 E43214
1200 E43215
1400 E43216
1600 E43217
450, without holes E43320
2000 E433562)
700, slotted E43333
1200, slotted E43334
2) only for sensor type LR2050
Coaxial pipes forLR level sensorswith G 3/4 male,industrial applica-tions
Materialstainless steel(1.4301 / 304)
Guided wave radar.Rods and coaxial pipes.
14
Continuous level measurementin contact with the medium
700 E43205
Length[mm]
Order no.
800 E43337
1000 E43207
1200 E43208
1400 E43209
1600 E43210
2000 E433532)
2) only for sensor type LR2050
3/4" NPT
240 E43377
Processconnection
Length[mm]
Order no.
450 E43218
700 E43219
1000 E43220
1200 E43223
1400 E43224
1600 E43221
2000 E43378
150 E43345
Length[mm]
Order no.
300 E43346
500 E43340
700 E43347
1000 E43341
1500 E43348
2000 E43342
Hygieniclevel sensortype LR2750
Rods forlevel sensorLR2750, hygienic
Materialhigh-gradestainless steel(1.4404 / 316L)
For a wide selection of
more accessories visit
www.ifm.com
For adapterssee pages26 - 27
For hygienic areasand viscous media
For industrialapplications
15
Hydrostatic.For industrial applicationson tanks and infree-flowing waterways.
Robust:Overload-protected measuringprinciples with a good long-termstability.
Compact:Pressure transmitters withoutdisplay and with analogueoutput.
Precise:Ceramic-capacitive and piezo-resistive measuring cells.
16
Type PApressure sensors
2-wire pressuretransmitters.
Ceramic-capacitivemeasuring cell. G 1/4 female 0...1000
Process connection Measuring rangeRelative pressure
[mbar]
Analogue output 4...20 mA
Order no.
PA3027
G 1/4 female 0...250 PA3028
G 1/4 female 0...1000
Analogue output 0...10 V
PA9027
G 1/4 female 0...250 PA9028
G 1/4 male 0...250 PA3528
G 1/4 male 0...100 PA3589
Order now?
www.ifm.com
Continuous level measurementin contact with the medium
For industrialapplications
17
For adapterssee pages26 - 27
Type PSsubmersiblepressure trans-mitters
PUR or FEP cablefor high resistanceto media.
Version withATEX approvalfor group I cat. M1and group II cat.1G and 1D.
Pressure compen-sation via inter-nally vented cable.
0...1000 PUR, 30 PS3617
Measuring rangeRelative pressure
[mbar]
Cable
[m]
Order no.
For standard applications, CE approval
0...1000 PUR, 15 PS3417
0...1000 FEP, 30 PS4607
For high resistance to media, CE approval
0...1000 FEP, 15 PS4417
0...600 FEP, 20 PS4506
0...1000 FEP, 15 PS317A
For hazardous areas, CE, Ex, GL approvals
0...600 FEP, 10 PS307A
0...250 FEP, 5 PS308A
0...600 FEP, 10 PS4407
0...250 FEP, 10 PS4408
0...250 FEP, 5 PS4208
0...600 PUR, 30 PS3607
0...600 PUR, 15 PS3427
0...600 PUR, 10 PS3407
0...250 PUR, 5 PS3208
Hydrostatic.For industrial applicationson tanks and infree-flowing waterways.
Robust:Overload-protected measuringprinciples with a good long-termstability.
Quick setting:Easy to use via 3 pushbuttons(type PN).
Clear:Large pointer display with LEDring (type PG).
Precise:Ceramic-capacitive and piezo-resistive measuring cells.
18
Processconnection
Factory settingMeasuring rangeRelative pressure
[mbar]
Factory settingMeasuring rangeRelative pressure
[mbar]
Order no.
2 switching outputs 1 switching output and 1 analogueoutput 4...20 mA / 0...10 V
Order no.
G 1/4 female 0...1000 0...1000 PN3097PN7097
G 1/4 male 0...1000 0...1000 PN3597PN7597
2 switching outputs or 1 switching output and 1 analogue output 4...20 mA / 0...10 V, scalable
G 1/4 female 0...1000 0...250 PN2098PN2097
G 1/4 male 0...1000 0...250 PN2598PN2597
G 1/4 female -500...500 PN2169
G 1/4 male -500...500 PN2569
PN typepressure sensors
Programmable2-colour display,clearly visibleswitch-point LEDs.
Rotatable processconnection.
Operation via3 raised push-buttons.
IO-Link.
Continuous level measurementin contact with the medium
For industrialapplications
19
Type PGpressure sensors
Optimum legibilitydue to theelectronic pointerdisplay.
Rotatable display.
Display of thetrend or of theminimum andmaximum values.
Processconnection
Factory settingMeasuring rangeRelative pressure
[mbar]
1 switching output and 1 analogue output 4...20 mA / 20...4 mA, scalable
Order no.
G 1/2 male 0...1000 PG2457
G 1/2 male 0...250 PG2458
G 1/2 male 0...100 PG2489
For adapterssee pages26 - 27
Hydrostatic.For hygienic applicationson large tanks. Hygienic:
Ingress resistance, materials andapprovals comply with hygienicrequirements.
Robust:Overload-resistant ceramic-capacitive measuring cells withlong-term stability.
Versatile:Variable process connections.
Precise:High overall accuracy (0.2 %).
Suitable for CIP/SIP:High temperature resistanceand electronic temperaturecompensation.
20
0...100 PG2789 PG2889
0...250 PG2798 PG2898
0...1000 PG2797 PG2897
-1000...1000 PG2799 PG2899
Type PGpressure sensors
Optimum legibilitydue to theelectronic pointerdisplay.
Rotatable display.
Display of thetrend or of theminimum andmaximum values.
Factory settingMeasuring rangeRelative pressure
[mbar]
Process connection
1 switching outputand 1 analogue output 4...20 mA / 20...4 mA, scalable
G1 male Aseptoflex VarioOrder no.
G1 male sealing coneOrder no.
0...1600 PM1717 PM1617
-1000...1000 PM1709 PM1609
0...1000 PM1707 PM1607
0...100 PM1789 PM1689
0...250 PM1708 PM1608
Type PM pressuretransmitters
Programmableanalogue output.
Free factorycertificate fordownload.
Accuracy 0.2 %.
IO-Link.
Factory settingMeasuring rangeRelative pressure
[mbar]
Process connection
Analogue output 4...20 mA, scalable
G1 male Aseptoflex VarioOrder no.
G1 male sealing coneOrder no.
available from September 2017
Continuous level measurementin contact with the medium
21
For hygienic areasand viscous media
For adapterssee pages26 - 27
Type PIpressure sensors
Programmableanalogue outputin 2-wire opera-tion.
Additionalswitching outputin 3/4-wire opera-tion.
IO-Link.
0...100 PI2789 PI2889
0...250 PI2798 PI2898
0...1000 PI2797 PI2897
-1000...1000 PI2799 PI2899
0...1600 PI2717 PI2817
Factory settingMeasuring rangeRelative pressure
[mbar]
Process connection
1 switching outputand 1 analogue output 4...20 mA / 20...4 mA
G1 male Aseptoflex VarioOrder no.
G1 male sealing coneOrder no.
Ultrasonic.For long distances anddifficult surfaces. Precise:
Precise and continuous levelmeasurement, e.g. of bulkmaterials.
Robust:High-grade stainless steel hous -ing for demanding applications.
Simple:Setting via teach button, wireteach or IO-Link.
Flexible:Normally closed / normally openprogrammable.
Versatile:Versions with two switching out-puts or switching and analogueoutputs 4...20 mA / 0...10 V.
Continuous level measurement without contact
22
Type UGTultrasonic sensors
Ultrasonic sensorsin cylindrical M18housing.
60 300
Housing length
[mm]
Max. range[mm]
Setting via
Switching output PNP NPN
Order no. Order no.
UGT500
60 800 UGT503
60 1200
wire
wire
wire UGT506
UGT521
UGT522
UGT523
60 300
Analogue output 4...20 mA 0...10 V
UGT501
60 800 UGT504
60 1200
wire
wire
wire UGT507
UGT502
UGT505
UGT508
98 1600
2 switching outputs PNP NPN
UGT509
98 2200 UGT512
button, IO-Link1)
button, IO-Link1)
UGT515
UGT518
98 1600
1 switching output PNP, 1 analogue output 4...20 mA 0...10 V
UGT510
98 2200 UGT513
button, IO-Link
button, IO-Link
UGT511
UGT514
98 1600
1 switching output NPN, 1 analogue output 4...20 mA 0...10 V
UGT516
98 2200 UGT519
button
button
UGT517
UGT520
1) IO-Link not for NPN version
23
For industrialapplications
300
Max.range[mm]
Setting via
1 switching output PNP,1 analogue output
4...20 mA 0...10 V
Order no. Order no.
UGT580
800 UGT582
1200
button
button
button UGT584
UGT581
UGT583
UGT585
300
1 switching output NPN,1 analogue output
4...20 mA 0...10 V
UGT586
800 UGT588
1200
button
button
button UGT590
UGT587
UGT589
UGT591
Type UGTultrasonic sensors
Ultrasonic sensorsin M18 Cubehousing.
Versions in plastic at
www.ifm.com
Photoelectric.For long distances.
Longest distance:Photoelectric level detectionof bulk materials and non-transparent liquids, for levelsup to 9.8 m.
Convenient:Scalable detection range withwindow function.
Reliable detection:Can be used in applicationsneeding background suppression.
Flexible mounting:Extensive range of fixingcomponents.
Continuous level measurement without contact
24
0.2...9.8 M12 connector < 15 x 15
Measuring range
[m]
Connection Light spot diameter
[mm]
2 switching outputs or 1 switching outputand 1 analogue output 4...20 mA / 0...10 V, scalable
Type O1Dphotoelectricdistance sensorwith time of flightmeasurement
Resistant to extra-neous light up to100,000 lux.
2 switching out-puts, one outputcan be configuredas analogue out-put.
4-digit alpha-numeric display.
Order no.
O1D300
Order now?
www.ifm.com
For industrialapplications
25
Accessories No. Description Order no.
Mounting brackethigh-grade stainless steel (1.4404 / 316 L) E21120
Clamp mounting setfor rod mount Ø 12 mm E2D101
Mounting adapterwith process connection G1 male E21224
Mounting rod, 100 mm, Ø 12 mm,M10 thread, stainless steel E20938
Mounting rod, 200 mm, Ø 12 mm,M10 thread, stainless steel E20940
Cube for mounting on an aluminium profile,M10 thread, stainless steel E20951
Mounting accessories
Protective cover, glass window E21171
Device protection
Cooling box E21248
Protective cover, PMMA window E21133
1
8
7
654
3
2
1
2
3
4
5
6
7
8
12
–
–
–
–
–
–
–
–
26
Accessories.Adapters for level sensorsin industrial and hygienicapplications.
Adapters G 1/2for type LMT
2
45
6
7
8
9
11
–
–
–
–
–
E43315
–
E43309
E43310
E43311
E43312
–
–
–
Clamp 1 - 1.5"
Process connectionNo. Order no. Order no.with leakage port
E33401
Mounting adapters for industrial and hygienic applications
Clamp 2" E33402
Hygienic pipe fitting, DN25 E43304
Hygienic pipe fitting DN40 E43305
Varivent type F DN25, D = 50 E43306
Varivent type N DN40...150, D = 68 E43307
Adapter G 1 E43303
Adapter G 3/4 E43302
Pipe fitting, DN25 SMS E33430
E33444Pipe fitting DN50 SMS –
Sealing plug G 1/2 E43308
Adapter 3/4" NPT E43313
Collar G 1/2 Ø 45 mm E30056
Welding adapters for industrial and hygienic applications
Ball G 1/2 Ø 35 mm E30055
Long version G 1/2 Ø 50 mm E43319
Welding mandrel G 1/2 E43314
For tanks G 1/2 Ø 30 mm E43300
For pipes G 1/2 Ø 29 mm E43301
T-piece DN25 E43316
T-pieces for industrial and hygienic applications
T-piece DN40 E43317
T-piece DN50 E43318
Clamp adapter for type LMT1041) E43349
Variable clamp adapters
Clamp adapter for type LMT1051) E43322
1) only in connection with G 1/2 female adapter
3
10
For a wide selection ofmore accessories visitwww.ifm.com
No. Description Order no.
G 1/2 E43375
Welding adapter
Adapter G 1/2for type LMC
25
1
2
3
4
4
5
6
7
9
10
8
8
25
12
11
–
–
27
For hygienic areasand viscous media
For industrialapplications
AdaptersG1 male /Aseptoflex Variofor typesPG, PI, LR
13
14
15
16
17
Flange DRD, D = 65 E33242
E33228
E33229
Varivent type F DN25, D = 50 E33221
Varivent type N DN40...150, D = 68 E33222
E33208
E33209
–
–
–
E33304
Clamp 1 - 1.5"
Process connectionNo. Order no. Order no. with leakage port
E33201
Mounting adapters for industrial and hygienic applications
Clamp 2" E33202
Hygienic pipe fitting DN32 E33211
Hygienic pipe fitting DN50 E33213
Hygienic pipe fitting DN40 E33212
Universal process adapter Rd52 E33340
Pipe fitting DIN 11864-1 A-BS –
E30130
–
Welding adapter Ø 50 mm E30122
Welding adapters for industrial and hygienic applications
Sealing plug E30128
18
19
20
21
Adaptersfor types LI, LK, LT
No. Description Order no.
Mounting clamp Ø 16 mm E43000
Welding adapter Ø 50 mm E43002
Mounting adapters
Climatic tube, 264 mm long E43100
Device protection
Climatic tube, 728 mm long E43102
Climatic tube, 472 mm long E43101
Mounting adapter G 3 E43003
Mounting adapter G 1 E43004
Mounting adapter 3/4" NPT E43012
Climatic tube, 132 mm long E43103
Want to find the
suitable connector?
www.ifm.com
No. Type Order no.
Flange plate 73 - 90 / G 3/4 E43201
Launching plate G 3/4 for type LRfor installation in plastic tanks E43380
Launching plate 3/4" NPT for type LRfor installation in plastic tanks E43381
Flange plate 65 - 80 / G 3/4 E43202
Mounting adapters
Protective cover E43910
Device protection
Adaptersfor types LR, LK
22
24
23
16
15
13
14
17
18
21
20
22
23
24
19
ifm a
rtic
le n
o. 7
8002
299
· We
rese
rve
the
right
to
mak
e te
chni
cal a
ltera
tions
with
out
prio
r no
tice.
· Pr
inte
d in
Ger
man
y on
non
-chl
orin
e bl
each
ed p
aper
. 03
/17
Visit our website:www.ifm.com
Position sensors
Sensors formotion control
Industrial imaging
Safety technology
Process sensors
Systems formobile machines
Industrialcommunication
Condition monitoringsystems
Connectiontechnology
Software
Power supplies
AccessoriesIO-Link
years
W
ARRANTY
on ifm products
Identification systems
ifm electronic gmbh
Friedrichstraße 145128 EssenTel. +49 / 201 / 24 22-0Fax +49 / 201 / 24 22-1200E-mail [email protected]