THE RHINO-5 LINE OF SOLAR CHARGE CONTROLLERS www.rogue-engr.com Multiple Versions Rogue offers multiple versions of the Rhino- 5 chargers including 6, 12 and 24 volt, LVD, SLA or Flooded Cell, and Non-temperature- compensated versions. See our catalog for information on our 10 and 20 amp models. Adaptable Output voltage automatically adjusts to compensate for the temperature of the battery. Rogue Engineering’s “3 stage” Rhino-5 Charge Controller is designed to operate with no maintenance in the most challenging industrial and recreational settings. This 5 amp controller consumes only 400 micro amps, the smallest self- consumption rate in the industry. The Rhino-5 Controller provides optimal battery performance. Simple and rugged, this charger can be powered by a solar panel or an AC adaptor for either on or off-grid systems. Why Rogue? We are a progressive company with an Electrical Engineering staff that thrives on solving problems. We believe that we are a leader in the industry of electronics and that separating ourselves from the competition will be accomplished through advanced technological hardware, quality workmanship and customer service. Why the Rhino-5 Charge Controller? Three Stage Automatic Charging The Rhino-5 is one of the only 5 amp chargers to feature Fast, Absorption and Float. The Rhino also switches from Fast charge to Float charge when batteries are full. Float charge continuously monitors battery to maintain a fully charged state. Linear Charging The Rhino-5’s Linear Charge method provides for steady charging while decreasing self- consumption. Urethane Encapsulation Rogue encapsulates all of its 5 and 10 amp chargers in Urethane to ensure reliability at low temperatures and a decreased failure rate. Testing and Reliability Each controller is fully tested and inspected, ensuring reliability. Convenient Pluggable Connectors for quick and easy installation. Compact simple design allows for use in hard to access locations. Rated For Hazardous Locations CSA Approved for Class 1, Division 2 Groups C, D T4 (Only on Model 136)

Upload: nguyennga

Post on 30-Sep-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

THE RHINO-5 LINE OF SOLAR CHARGE CONTROLLERS

www.rogue-engr.com

Mult iple Vers ions

Rogue of fer s mult ip le ver s ions of the Rhino -

5 charger s inc luding 6, 12 and 24 vo l t , LVD,

SL A or F looded Cel l , and Non -temperature -

compensated ver s ions . See our cata log for

information on our 10 and 20 amp models .

Adaptable

Output vo l tage automatica l ly adjust s to

compensate for the temperature of the

bat ter y.

Rogue Engineer ing ’s “3 s tage” Rhino -5 Charge

Contro l ler i s des igned to operate with no

maintenance in the most chal lenging industr ia l

and recreat ional set t ings . This 5 amp contro l ler

consumes only 4 0 0 micro amps, the smal les t se l f-

consumption rate in the industr y. The Rhino -5

Contro l ler prov ides opt imal bat ter y per formance.

S imple and rug ged, th is charger can be powered

by a so lar panel or an AC adaptor for e i ther on or

of f- gr id sys tems.

Why Rogue?

We are a progress ive company with an Elec tr ica l

Engineer ing s taf f that thr ives on so lv ing problems.

We bel ieve that we are a leader in the industr y

of e lec tronic s and that separat ing our selves f rom

the competi t ion wi l l be accompl ished through

advanced technologica l hardware, qual i t y

workmanship and customer ser v ice.

Why the Rhino -5 Charge Control ler?

Three Stage Automatic Charging

The Rhino -5 i s one of the only 5 amp charger s

to feature Fast , Absorpt ion and F loat . The Rhino

a lso switches f rom Fast charge to F loat charge

when bat ter ies are fu l l . F loat charge cont inuously

monitor s bat ter y to maintain a fu l ly charged

s tate.

L inear Charging

The Rhino -5’s L inear Charge method prov ides

for s teady charging whi le decreas ing se l f-

consumption.

Urethane Encapsulat ion

Rogue encapsulates a l l of i t s 5 and 10 amp

charger s in Urethane to ensure re l iab i l i t y at low

temperatures and a decreased fa i lure rate.

Test ing and Rel iabi l i t y

Each contro l ler i s fu l ly tes ted and inspec ted,

ensur ing re l iab i l i t y.

Convenient

Plug gable Connec tor s for quick and easy

ins ta l lat ion. Compac t s imple des ign a l lows for

use in hard to access locat ions .

Rated For Hazardous Locat ions

C SA Approved for C lass 1, D iv is ion 2 Groups C , D

T4 (Only on Model 136)

��������

���� �

����

���� ���

� �����

��� �������� ���

������������

� �� ����� �

���� �

���

���� ���

� �� ����� �

���� ��������

�� �������

����������

��������� ���� � ��� ���� �������� ���� ���� � ��� ���� ���� ������������

��������� ��� � ��� ���� ������ ���� ���� � ���� ���� ���� ��

�������� ��� � ��� ���� ������ ���� ���� � ���� ���� � � ���� ��

��������� ��� � ��� ���� �������� ���� ���� � ��� ���� ���� ��

��������� ��� � ��� ���� ������ ���� ���� � ���� ���� ���� ��

��������� ��� � ��� ���� �������� ���� ���� � ��� ���� � � ���� ��

�������� ��� � ��� ���� ������ ���� ���� � ���� ���� � � ���� ��

�������!� ���� � ��� ���� �������� ���� ���� � ��� ���� ��� ��

�������"� ��� � ��� ���� �������� ���� ���� � ��� ���� ��� ��

��������� ���� � ��� ���� �������� ���� ���� � ��� ���� � � ���� ��