1THE PRODUCT

1THE PRODUCT

REACTORS MADE ENTIRELY WITH SINTERIZED TITANIUM DIOXIDE

Quick and simple installation

THE REACTOR

ELECTRONICS WITH HIGH REALIABILIT AND SIMPLE INSTALLATION, MAINTENANCE AND USE

Electronic box made in IP 21 or IP 55

1THE PRODUCTTHE ELECTRONICS

1THE PRODUCTTHE AIM

Disinfect and remove pollutants without using chemical products

How?Using hydroxyl radicals

1THE PRODUCTTHE TECHNOLOGY

1THE PRODUCTTHE TECHNOLOGY

Oxydazyn molecule eVFlouride 2,87Hydroxyl radical 2,80Oxygen ion 2,42Ozone 2,07Oxygen peroxide 1,78Hypoclorous acid 1,48Chlorine 1,36Oxygen 1,23Bromine 1,07Chlorine dioxide 0,95

Speed reaction OH O3

Chorine alquenes 109-1011 10-1-103

Phenols 109-1010 103

Aromatic 108-1010 100-102

Cetones 109-1010 100

Alcohols 108-109 10-2-100

Alcanes 106-109 10-2

1THE PRODUCTTHE TECHNOLOGY

Optimal conditions of work

1. 4,5 < pH < 10,52. Solids: filtering system minimum 800u3. 5ºC<T(ºC)<55ºC4. Ions Fe/mg/mn/Ca: ↓effectiveness5. P<6 bar

1THE PRODUCTTHE WHOLE

Very versatileFlows to treat only with one equipment:

Installation Minimum flow Maximum flowIn line 0,2 m3/h 400 m3/hIn recirculation 0,2 m3/h 4000 m3/h

SCANDINAVIAN TECHNOLOGYSPANISH DEVELOPMENT

1THE PRODUCTCERTIFICATIONS

Equipment suitable for use in disinfection of drinking water.

1THE PRODUCTCERTIFICATIONS

1THE PRODUCTBENEFITS

SUSTAINABLEMinimum energy consumption

h2O.TITANIUM Model 0,5 1 5 10 20 50 100 200 300 400In line 15 26 95 200 380 700 1300 2700 2700 4600In recirculation 1 1 1 2 4 7 13 27 27 46

1THE PRODUCTBENEFITS

VERSATILEWide range of applicationMinimum pressure drop

h2O.TITANIUM Model 0,5 1 5 10 20 50 100 200 300 400Ratio in line (m3/h) 0,5 1 5 10 20 50 100 200 300 400Pressure drop (bar) <0,1 <0,1 <0,1 <0,1 <0,1 <0,1 <0,1 <0,2 <0,2 <0,2

1THE PRODUCTBENEFITS

DO NOT MODIFY THE PHYSICOCHEMICALProperties of the water

Long useful life: 25 years minimumDo not damage people, animals or plants

Ecologyc: Do not use chemical productsInstallation and maintenance: Low CostVery competitive price: Relation cost/AIM

2AREAS OF APPLICABILITY

2AREAS OF APPLICABILITY

DisinfectionReuseColour reductionTurbidity reductionPollutants removal

2DISINFECTIONAUTOMOTIVE

2DISINFECTIONNISSAN MOTORS BARCELONA (SPAIN)

AIM: Microorganisms reduction in the phosphatation process to prevent damages in the cataphoresis process.

2DISINFECTIONNISSAN MOTORS BARCELONA (SPAIN)

h2O.TITANIUM Model AOP 20

in recirculation position to treat

10m3 of water width 163 m3/h of flow

2DISINFECTIONNISSAN MOTORS BARCELONA (SPAIN)

RESULTS: 3 logarithmic units of reduction constanty in the time

2DISINFECTIONHOSPITALS

2DISINFECTIONLA FE UNIVERSITARY HOSPITAL OF VALENCIA (SPAIN)

AIM: Disinfect the water of a group of 6 cooling towers to prevent the legionella presence

2DISINFECTIONLA FE UNIVERSITARY HOSPITAL OF VALENCIA (SPAIN)

Reactor h2o.TITANIUM model AOP50 in recirculation position

2DISINFECTIONLA FE UNIVERSITARY HOSPITAL OF VALENCIA (SPAIN)

RESULTS: 3 logarithmic units of reduction constantly in the time

2DISINFECTIONCOMMUNITY HOSPITAL OF LONDON (U.K.)

AIM: Improve water quality by replacing the chlorine dioxide unit for h20.TITANIUM technology

2DISINFECTIONCOMMUNITY HOSPITAL OF LONDON (U.K.)

RESULTS: Clear and significant decrease of Legionella contamination and costs of maintenance

The reduction in colony count at 22 and 37ºC was 99.9% and 100% respectively.

2DISINFECTIONNUCLEAR POWER PLANTS

2DISINFECTIONTREATMENT NUCLEAR WASTE PLANT OF SELLAFIELD (U.K.)

AIM: Disinfect the water of a cooling circuit using h2o.TITANIUM as a complementary technology of Gamma Rays to prevent legionella presence.

2DISINFECTIONTREATMENT NUCLEAR WASTE PLANT OF SELLAFIELD (U.K.)

Results: Water perfectly disinfected without using any chemicals

2REUSEWATER WASTE PLANTS

2REUSEWATER WASTE PLANT IN VALENCIA (SPAIN)

AIM: Disinfection of water in the tertiary treatment for reuse for irrigation

2REUSEWATER WASTE PLANT IN VALENCIA (SPAIN)

2REUSEWATER WASTE PLANT IN VALENCIA (SPAIN)

RESULTS: 2 logarithmic units of reduction constantly in the time with only one pass through the reactor

% effectiveness C. Total C. Fecals E. Coli E. Fecals99 33 33 40 2097 67 83 60 4095 100 100 80 8090 100 100 80 100

2REUSEWATER WASTE PLANT IN VALENCIA (SPAIN)

2COLOUR REDUCTIONFISH ALARMS

2COLOUR REDUCTION EEL FISH FARM IN VALENCIA (SPAIN)

AIM: Reduce the orange color of the water caused by the presence of humic acids

2COLOUR REDUCTIONEEL FISH FARM IN VALENCIA (SPAIN)

RESULTS: Colour reduction by 92% without altering the physicochemical properties of water

2COLOUR REDUCTION EEL FISH FARM IN VALENCIA (SPAIN)

RESULTS: One (1) pH unit reduction

2COLOUR REDUCTIONEEL FISH FARM IN VALENCIA (SPAIN)

RESULTS: No variability of NO3 concentration

2COLOUR REDUCTION EEL FISH FARM IN VALENCIA (SPAIN)

RESULTS: No variabiity of NH4 concentration

2TURBIDITY REDUCTIONFISH FARMS

2TURBIDITY REDUCTION FARM OF SEA BASS IN VALENCIA (SPAIN)

AIM: Turbidity reduction and improvement of water quality comparing the effect of the h2o.TITANIUM vs UV Equipments.

2TURBIDITY REDUCTIONFARM OF SEA BASS IN VALENCIA (SPAIN)

Results: Turbidity reduction by 95% remaining constant in time

2TURBIDITY REDUCTION FARM OF SEA BASS IN VALENCIA (SPAIN)

RESULTS: Turbidity reduction by 95% irrespective of the amount of feed added.

3INSTALLATION AND MAINTENANCE

3INSTALLATION REACTOR

Standard equipment- Reactor- Control Cabinet Box PLS 201- Connecting cables: - Sensor cable: 5.0 m - UV Lamp cable: 4.5 m

WARNING!Non-mains qualituy watert may require pre-filtration prior to treatment with the Titanium AOP System.Never operate the Titanium AOP system without firs ensuring the reactor vessel and system contains water.

3INSTALLATION REACTOR

3INSTALLATION REACTOR

1. May be mounted on the wall or within a purpose built frame.2. Must not be installed in a place that is at risk from freezing.3. Must be installed on either stainless steel or plastic pipes.4. The h2o.TITANIUM is intended for indoor use only - do not installa where exposed to the weather. If so, please protect it.

3INSTALLATION REACTOR

Supply system cable to abinet: 1.5 mSensor cable: 5.0 mUV lamp cable: 4.5 mCover and protection of the equipmentIP Units

Model h2o.TITANIUM Minimum distance for UV lamps ex-traction

AOP 05* 50 cmAOP 1 75 cmAOP 5 150 cmAOP 10, 20, 50, 100, 400* 200 cm

3INSTALLATIONUV LAMPS AND SLEEVES

3MAINTENANCE CLEANING AND REPLACING

4ELECTRONIC PARTS

4

4ELECTRONIC PARTSMONITOR & SYSTEM CONTROLLER

UVM-200 is programmable UV monitoring unit cooperating with digital UV sensor from UVS-100T.

Complete measuring system consists of 2 basic parts digital UV sensor and UVM-200 monitor.

Measurements are taken by sensor part and after conversion to digital form are transmitted over digital bus to monitoring unit.

4ELECTRONIC PARTSMONITOR & SYSTEM CONTROLLER

Monitor displays actual UV level and classifies it into one of three zones: normal, warning and alarm.Actual UV zone is displayed in LED display.

UVM-200 is programmable instrument with LCD display - all basic parameters can be changed using built-in programming menu.

It can control external devices respectively to measured UV level with the help of built-in optically isolated relays.

4ELECTRONIC PARTSMONITOR & SYSTEM CONTROLLER

4ELECTRONIC PARTSUV SENSOR-UVS 100 T

Sensor M12x1 male connector and signal pin-out

4ELECTRONIC PARTSUVS 100 T & UVM 200

Complete UV monitoring system based on UVS-100T Radiometer (sensor part) and UVM-200 monitor.

Digital UV and temperature sensor

UVS-100T

4ELECTRONIC PARTSUV LAMP PROGRAMMABLE DRIVER

Programmable current source (425mA and 800mA) delivering lamp discharge current.One for all - same unit can work all lamps within given family of UV lamps (regardless of length and power).Programmable lamp pre-heating profile.Lamp parameters checked on-line in real time:discharge current, discharge voltage (lamp dynamic resistance) filament current, filamente voltage (filament dymanic resistance)On-line lamp diagnosticsVersion with lamp on-line diagnostic interface (OK, Warn, Fault)

4ELECTRONIC PARTSUV LAMP PROGRAMMABLE DRIVER

4

4ELECTRONIC PARTSCOMPLETE SYSTEM

4ELECTRONIC PARTSBASIC DIAGNOSTIC PROCEDURE

Components PLS 201L and UVM 200 sends signals wich inform user of quality of work UV lamps.

PLS 201L send one of three signals (by LED):

START/OK - Correct lamp state WARNING - Warning detected (one of filaments broken, lamp parameters indicating end-of-life condition, etc...) FAULT - Unit failed to maintain discharge in lamp (lamp broken, etc...)

4ELECTRONIC PARTSBASIC DIAGNOSTIC PROCEDURE

Discharge maintained.Lamp state OK.

Discharge maintained.Lamp can still workCheck lamp connections and filaments after power off.

Discharge NOT maintained.Switch off and check lamp connections, check filaments.