the powerpoint templates of arcadisd19336bb-7d06-4958-9e7e...no extra emission for remedial...

14
SANERGY A concept for a sustainable remediation G.H. Pelgrum, Manager Soil Group August 7, 2008 Imagine the result

Upload: phungthu

Post on 03-Apr-2018

218 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

SANERGY A concept for a sustainable remediation

G.H. Pelgrum, Manager Soil GroupAugust 7, 2008

Imagine the result

Page 2: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Project Profile

Combining groundwater energy and groundwater remediation during the redevelopment of an industrial complex in Eindhoven

Page 3: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Philips’ Strijp-S in Eindhoven

27 hectares in Eindhoven city centre

In use since 1915

Fully built in 1930

At peak 10,000 employed (“Forbidden City”)

Cradle of many Philips innovations

Page 4: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Philips’ Strijp-Sin Eindhoven

Redevelopment as of 2005

Mix housing, business & leisure

Maintain historical buildings

New housing areas and offices

Stringent criteria for sustainability

In 2003,Philips indicates it prefers to use groundwater energy

Page 5: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Major groundwater contamination

Chlorinated solvents cisDCE and VC In aquifer from 30 to 60 m-bgs

Page 6: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Can we do this

9

The client:

Park Strijp Beheer and Philips

The question : Is it possible to use groundwater energy at this site, and to combine this with the remediation of groundwater ?

Page 7: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

The first energy remediation

system worldwide

ARCADIS role

Design groundwater system and Installations

Impact Assessment

Groundwater and temperature modeling

Permitting

Page 8: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Energy and remediation

combined

Technical issues

Tradional Heat-cold storage will spread contaminants: containment is required

Seasonal variations in energy demand

On-going developments

Permit issues

Groundwater regulations

Soil Protection regulations

Environmental Impact Assessment

Page 9: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Our solution: recirculation system, no storage

Page 10: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Stimulating natural degradation

Page 11: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

What about sustainability?

Per year Gas (m3)

Electricity(kWh)

CO2(ktonnes)

Traditional heating 2.900.000 2.400.000 6,0

Sanergy 570.000 5.300.000 3,0

CO2 reduction of 3.0 ktonnes for heating/cooling!

No extra emission for remedial activities in groundwater!

Page 12: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Financial perspective

Construction of Sanergy 20-40 % more expensive. No additional remediation costs - which compensate for the higherconstruction costs.Sanergy in exploitation period equals normal energy systemBreak-even point in 7-10 years, lifetime of system 30 years.

Page 13: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Sanergy:Sustainable

and innovative solution

Out of the box thinking

Clear CO2 reduction

Less use of non renewables(gas)

Remediation creates noadditional environmentalburden

Cost-effectiveness

ARCADIS design fits client’sperspective:

Sense and Simplicity !

Page 14: The PowerPoint templates of ARCADISD19336BB-7D06-4958-9E7E...No extra emission for remedial activities in groundwater! Financial perspective Construction of Sanergy 20-40 % more expensive

Imagine the result