the park2 wake model - documentation and validation€¦ · however, where jensen’s eq.(7) and...

25
General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. Downloaded from orbit.dtu.dk on: Apr 19, 2021 The Park2 Wake Model - Documentation and Validation Rathmann, Ole Steen; Hansen, Brian Ohrbeck; Hansen, Kurt Schaldemose; Mortensen, Niels Gylling; Murcia Leon, Juan Pablo Publication date: 2018 Document Version Publisher's PDF, also known as Version of record Link back to DTU Orbit Citation (APA): Rathmann, O. S., Hansen, B. O., Hansen, K. S., Mortensen, N. G., & Murcia Leon, J. P. (2018). The Park2 Wake Model - Documentation and Validation. DTU Wind Energy E Vol. 160

Upload: others

Post on 03-Nov-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.

Users may download and print one copy of any publication from the public portal for the purpose of private study or research.

You may not further distribute the material or use it for any profit-making activity or commercial gain

You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from orbit.dtu.dk on: Apr 19, 2021

The Park2 Wake Model - Documentation and Validation

Rathmann, Ole Steen; Hansen, Brian Ohrbeck; Hansen, Kurt Schaldemose; Mortensen, Niels Gylling;Murcia Leon, Juan Pablo

Publication date:2018

Document VersionPublisher's PDF, also known as Version of record

Link back to DTU Orbit

Citation (APA):Rathmann, O. S., Hansen, B. O., Hansen, K. S., Mortensen, N. G., & Murcia Leon, J. P. (2018). The Park2Wake Model - Documentation and Validation. DTU Wind Energy E Vol. 160

Page 2: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

The Park2 Wake Model - Documentation and Validation

Ole Steen Rathmann, Brian Ohrbeck Hansen, Kurt S. Hansen, Niels Gylling Mortensen, Juan Pablo Murcia Leon1 1Vestas Power Solutions Report DTU Wind Energy E-0160 April 2018

Page 3: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),
Page 4: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

The Park2 Wake Model - Documentation and Validation Report DTU Wind Energy E-0160 April 2018 By Ole Steen Rathmann, Brian Ohrbeck Hansen, Kurt S. Hansen, Niels Gylling Mortensen, Juan Pablo Murcia Leon1 1Vestas Power Solutions Copyright: Reproduction of this publication in whole or in part must include the customary

bibliographic citation, including author attribution, report title, etc. Cover photo: Fog-stripes in the wakes of the Horns Rev 1 Wind Farm Published by: Department of Wind Energy, Frederiksborgvej 399 Request report from:

www.dtu.dk

ISSN: [0000-0000] (electronic version) ISBN:

[987-87-93549-28-9] (electronic version)

ISSN: [0000-0000] (printed version) ISBN: [987-87-93549-28-9] (printed version)

Page 5: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

Preface

This report describes the revised Park-model, Park2, and the validation and calibration of it. The Park2 model is implemented the WAsP 12 software package. Roskilde, April 2018 Ole Steen Rathmann Senior Researcher

Page 6: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

Content

Summary .......................................................................................................................... 6

1. Introduction and Background .................................................................................. 7

2. The consistency flaw of Park1 ................................................................................ 7 2.1 The NOJ formulation .............................................................................................................. 7 2.2 Park1 formulation ................................................................................................................... 8

3. Park2: The consistent formulation. ......................................................................... 9 3.1 Surface reflection ................................................................................................................. 10

4. Selected Off-shore Wind Farm Data for Comparison ............................................ 10

5. Qualitative comparison of the effect of Park2-features to offshore windfarm data. 12 5.1 Test results .......................................................................................................................... 13 5.2 Findings from the qualitative comparisons of the effect of the Park2-features ..................... 16

6. Quantitative validation and calibration of Park2 based on offshore wind farms. .... 17

7. Qualitative Validation of Park2 against offshore wind farm data. .......................... 17 7.1 Findings from the qualitative validations. ............................................................................. 21

8. Calibration of Park2 for on-shore conditions vs. Park1 ......................................... 22

9. Conclusion ............................................................................................................ 23

References ..................................................................................................................... 23

Acknowledgements ......................................................................................................... 24

Page 7: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

6

Summary

The WAsP Park wake model has been revised to ensure physical consistency. For off-shore conditions the revised Park2 wake model has been calibrated and validated against production data from a number of off-shore wind farms. For on-shore conditions, the Park2 wake model has been calibrated against predictions by the original Park model for a number of on-shore wind farms. The calibrations have resulted in recommended values for the wake decay constant of the revised Park2 wake model.

Page 8: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

7

1. Introduction and Background The DTU Wind Energy Wind Atlas and Analysis and Application Program (WAsP) has for a long time used the Park wake model – hereafter referred to as Park1 - to calculate wake effects within wind farms. Park1, originally a stand-alone program (Katic et al., 1986), (Sanderhoff, 1983), is based on the so-called NOJ wake model (Jensen N.O., 1983) that uses a simple top-hat speed profile in the wake downwind of a wind turbine, the wake expanding simply linearly like a cone. However, for the interaction of wakes inside a wind farm, Park1 does not follow the NOJ wake model strictly, but uses an empirical procedure. The empirical procedure consists of an unconventional formulation of the speed deficit contribution from a certain in-farm wind turbine (in-farm: a turbine itself in the wake of another turbine), and a wake superposition model based on a quadratic summation rule for adding speed deficit contributions. In addition, wake interaction with the ground or water surface is represented by simple reflection. Others have adapted the same formulation (Nygaard 2015). The empirical procedure, however, has a consistency flaw since it will predict a ghost-turbine1 to have an unphysical effect on turbines downwind of it. Thereby a ghost-turbine will also have an unphysical effect on the total production of the wind farm. Park2 is a revision of the Park1-model, still with the simple wake representation by a top-hat profile based on the NOJ-model, but with a changed speed deficit and wake interaction formulation that removes the consistency flaw.

2. The consistency flaw of Park1 The original Park1 model was based on the NOJ-wake model (Jensen 1983), and below we will give the most relevant details from this formulation.

2.1 The NOJ formulation In his original publication, N.O.Jensen (Jensen, 1983, eq.2) states the following approximate expression for the speed in the wake at a distance x downwind of a single turbine:

2

0( ) 1 2 = − +

RV x U aR kx

(2.1.1a),

corresponding to a speed deficit of

2

0 0( ) ( ) 2 ∆ = − = + RV x U V x U a

R kx (2.1.1b)

Here a is the factor of influence with 2 1 1 ta C= − − where Ct denotes the thrust-coefficient2.

(In his publication Jensen actually uses the optimum value a=1/3). R of course denotes rotor radius =½D, and k is a wake decay constant. A top-hat speed-deficit profile is assumed where inside the wake of diameter ( )+ −i iR k x x the speed deficit has a value as given by eq. (2.1.1b)

but is zero outside the wake.

1 Ghost-turbine: A turbine with zero or very small thrust and power production for all wind speeds. 2 Thrust on the rotor T = ½ρair ArotorV2*Ct

Page 9: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

8

Further, in the same publication (eq.7) N.O.Jensen states the following approximate expression for the incident wind speed at rotor #2 in a single row along the wind speed under the impact of the two upwind turbines #0 and #1:

2

2 1

0 0 1,2

1 1 (1 2 )

= − − − + ∆

inc incV V RaU U R k x

(2.1.2)

This corresponds to a speed deficit of

( )2

2 0 2 0 11,2

(1 2 )

∆ = − = − − + ∆

inc inc inc RV U V U V aR k x

(2.1.3)

Here it should be observed that Jensen’s eq.(7) is stated as an approximation to the resulting reduced wind speed – i.e. eq.(2.1.3) above should be seen as an approximation to the total speed deficit originating from the wakes of turbine #0 and #1.

2.2 Park1 formulation In the original Park model (Katic et al. 1986; Sanderhoff 1993 ) as well as in the present WAsP/Park model (WAsP8-WAsP11) the wake speed deficit originating from a certain in-Park turbine #i, based on the NOJ-wake model (Jensen 1983), is taken to be

( )2

0( ) 1 ( )2 ( )

∆ = − − + −

inc inc ii i t i

i i

DV x U V C VD k x x

(2.2.1)

Here x is the downwind coordinate (xi being the x-coordinate of turbine #i) and Viinc is the incident wind speed on rotor #i, and as in the NOJ-model a top-hat speed-deficit profile is assumed. It should be noticed that the turbine thrust coefficient Ct is evaluated on basis of the incident wind speed at a turbine (NOT on basis of the free wind speed). For the incident wind speed at some turbine #j, downwind of turbine #i, a factor is included to account for partial overlap between the wake and the rotor area of turbine #j:

,( ) ( )overlapi jeff

i j i j rotorj

AV x V x

A∆ = ∆ (2.2.2)

The resulting incident wind speed at a rotor #j is found using an empiric quadratic summation rule for all the speed deficits of all relevant wakes (originating from upwind turbines):

20 ( )

upwind turbinesincj i j

iV U V x= − ∆∑ (2.2.3)

As wake interaction with the surface is represented as simple reflection, the sum in the above eq.(2.2.3) includes wakes originating from real turbines as well as from “reflected turbines”, i.e. turbines with the same horizontal positions as the real turbines but with a formal hub-height of –hi (hi being the hub height of real turbine #i). Others have adopted that same formulation ( e.g. Nygaard, 2015). The above empirical formulation has the obvious unphysical consequence – inconsistency – that a “ghost-turbine” will have a speed-deficit impact just from the fact that it has a non-zero incident speed deficit, i.e. if 0 0inc

iU V− > . It is obvious that a physical formulation should fulfil

the requirement that the speed deficit impact from some turbine should tend to zero when the Ct of that turbine tends to zero.

Page 10: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

9

Now, simple inspection reveals that eq.(2.2.1) is in fact identical to Jensen’s eq.(2.1.3), and it is tempting to think that the inspiration to use eq.(2.2.1) is in fact Jensen’s eq.(7) – or eqs.(2.1.2) and (2.1.3) above. However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1), eq.(2.2.1) is used as the contribution from just a single upwind turbine: the total resulting speed deficit is obtained by combining the contributions from the individual wakes from upwind turbines using quadratic summation, eq.(2.2.3). Thus, by using eqs.(2.2.1)-(2.2.3) the impact of upwind turbines is in fact included twice. Consequently, we do not consider it correct to use formulation (2.2.1). The relative success of the inconsistent formulation (2.2.1)-(2.2.3) could be due the use of quadratic summation, which mainly considers the large contributions and thus counteracts the double inclusion of upwind wake effects as described above.

3. Park2: The consistent formulation. As stated previously, in the Park2 model we stick to the simple NOJ single-wake model with its top-hat profile and its linear wake expansion. Now, contrary to Park1, the Park2 model takes the partial effect of a certain turbine to be equal to the wake effect downwind of that turbine in the following virtual situation: (1) had there been no other turbines, and (2) had the virtual free wind speed been the actual incident wind speed at that turbine. Thus, based on eq.(2.1.1b), the partial speed deficit originating from a certain turbine #i is

( )2

( ) 1 1 ( )2 ( )

∆ = − − + −

inc inc ii i t i

i i

DV x V C VD k x x

(3.1 a)

For easy notation we introduce the wake diameter ( ) 2 ( )= + −wakei i iD x D k x x , thus

( )2

( ) 1 1 ( )( )

inc inc ii i t i wake

i i

DV x V C VD x x

∆ = − − −

(3.1 b)

This formulation (3.1) ensures consistency since a Ct tending to zero will imply that ΔVi tends to zero as well. When estimating the combined effect of overlapping wakes Park2 uses classical perturbation theory, thus assuming that, at some point, the speed-deficit effects from the individual turbines are sufficiently small that they may be simply added. In other words, we apply a linear wake superposition. So, taking into account the effect of partial overlap between a wake and a rotor we find the resulting incident wind speed at a turbine #j

,0 ( )= − ∆∑

overlapupwind turbinesi jinc

j i j rotori j

AV U V x

A (3.2)

Here Arotor and Aoverlap denote the rotor area and the area of the part of the partial wake overlapping the rotor, respectively.

Page 11: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

10

3.1 Surface reflection The Park1 model (Katic et al., 1986), (Sanderhoff, 1983) used surface reflection of the individual wakes to represent the interaction with ground- or water-surface. The reflected wakes were then treated as “additional wakes” added up together with “true” wakes in the wake superposition procedure. However, use of surface reflection together with the consistent formulation and using linear wake superposition (eqs. (3.1), (3.2)) seems problematic. Initial investigations (section 4.2) showed that very large values of the wake decay constant would have to be assumed to get results similar to what has been observed in large off-shore wind farms. In addition, CFD-studies (Ott, 2011, Ott, 2014) have indicated that the wake-interaction with the surface is not described correctly by simple reflection since the wake expansion is a diffusion-like process occurring in a flow with a log-like vertical profile. Consequently, the speed deficit must tend to zero at the surface, which is not fulfilled by a reflection model. Hence, in Park2 wake surface reflections are simply omitted.

4. Selected Off-shore Wind Farm Data for Comparison

Operational data from three “primary” Danish and Swedish off-shore wind farms, including production details for individual turbines, have been used for qualitative validation and calibration of the Park2 model:

a) The Horns Rev wind farm, 1.Jan. 2005 – 31.Dec. 2009; b) the Nysted wind farm, 24.May 2004 – 16.Nov.2006; and c) the Lillgrund wind farm. 1.Jan. 2008 – 31.Dec. 2012.

Data from a “secondary“ wind farm was included, but only as a reference regarding total wind farm production: Anholt wind farm, Jan.2013-June 2015.

Wind farm Country Number of turbines

Turbine Wind farm rated power (MW)

Comparison use Rated

power (MW)

Hub height (m)

Rotor diameter (m)

Primary Wind Farms Horns Rev 1 DK 80 2 69 80 160

Turbine power production

Nysted DK 72 2.33 69 82 167.8 Lillgrund S 48 2.3 65 92.6 110.4 Secondary wind farm Anholt DK 111 3.6 81.6 120 399.6

W.F.power production, for reference only

The locations and the layouts of the wind farms are shown below.

Page 12: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

11

Figure 1. Locations of the wind farms used in this study. Figure 1. The locations of the wind farms are indicated (produced by Google Earth).

Figure 2. The Horns Rev wind farm layout with selected wind directions.

Figure 3. The Nysted wind farm layout with the selected wind directions.

Figure 4. The Lillgrund wind farm layout with the selected wind directions.

Figure 5. The Anholt wind farm layout.

WT01

WT02

WT03

WT04

WT05

WT06

WT07

WT08

WT11

WT12

WT13

WT14

WT15

WT16

WT17

WT18

WT21

WT22

WT23

WT24

WT25

WT26

WT27

WT28

WT31

WT32

WT33

WT34

WT35

WT36

WT37

WT38

WT41

WT42

WT43

WT44

WT45

WT46

WT47

WT48

WT51

WT52

WT53

WT54

WT55

WT56

WT57

WT58

WT61

WT62

WT63

WT64

WT65

WT66

WT67

WT68

WT71

WT72

WT73

WT74

WT75

WT76

WT77

WT78

WT81

WT82

WT83

WT84

WT85

WT86

WT87

WT88

WT91

WT92

WT93

WT94

WT95

WT96

WT97

WT98

423 424 425 426 427 428 429 430

Easting (km) UTM Zone32

6147

6148

6149

6150

6151

6152

Nor

thin

g (k

m)

222

270

242

WT11WT21

WT31WT41

WT51WT61

WT71WT81

WT12WT22

WT32WT42

WT52WT62

WT72WT82

WT13WT23

WT33WT43

WT53WT63

WT73WT83

WT14WT24

WT34WT44

WT54WT64

WT74WT84

WT15WT25

WT35WT45

WT55WT65

WT75WT85

WT16WT26

WT36WT46

WT56WT66

WT76WT86

WT17WT27

WT37WT47

WT57WT67

WT77WT87

WT18WT28

WT38WT48

WT58WT68

WT78WT88

WT19WT29

WT39WT49

WT59WT69

WT79WT89

673 674 675 676 677 678Easting (km) UTM Zone 32

6046

6047

6048

6049

6050

Nor

thin

g (k

m)

Nysted

263

278

320

A-01

A-02

A-03

A-04

A-05

A-06

A-07

B-01

B-02

B-03

B-04

B-05

B-06

B-07

B-08

C-01

C-02

C-03

C-04

C-05

C-06

C-07

C-08

D-01

D-02

D-03

D-04

D-06

D-07

D-08

E-01

E-02

E-03

E-04

E-06

E-07

F-02

F-03

F-04

F-05

F-06

G-02

G-03

G-04

G-05

H-02

H-03

H-04

358.5 359 359.5 360 360.5 361 361.5Easting (km) UTM Zone 33

6152.5

6153

6153.5

6154

6154.5

6155

6155.5

Nor

thin

g (k

m)

Lillgrund180

120

222255

Row BRow C

Row A

Row B

A01A02A03A04A05A06A07A08A09A10A11A12A13A14A15A16

A17A18

A19A20

A22A23

A24A25

A26A27

A28A29

A30A31

B01C01

C02

C03

C04

C05

C06

C07

C09

C10

C12

C31

D01E01

F01

F02

F03

F04

F05

F06

F07

F08

F09

F10

F11

F12

F13

F14

F23F24

F25

F26F27

F28F29

G01H01

I01

I02

I03

I04

I05

I07

I08

I10

I28

J01K01

L01L02L03

L04L05

L06

M01P01P02

P03P04

P05P06

P07P08

P09P10

P11P12

P13

P15P16

P17

P19P20

P21P22

P23P24

P25P26

P27P28

630 632 634 636 638 640 642 6446264

6266

6268

6270

6272

6274

6276

6278

6280

6282

6284

6286

6288

Easting (km) UTM Zone 32

Nor

thin

g (k

m)

Page 13: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

12

For each of the three primary wind farms, a number of flow cases have been selected and used for validation and calibration. For all three wind farms the following three speed-cases were used:

Hub-height Wind Speed 8.0 +/- 0.5 m/s 10.0 +/- 0.5 m/s 12.0 +/- 0.5 m/s

Each wind speed case was used in combination with 3 or 4 wind direction-cases: Hub-height Wind Direction Horns Rev 1 222.0 +/- 7.5 ° 242.0 +/- 7.5 ° 270.0 +/- 7.5 ° Nysted 263.0 +/- 7.5 ° 278.0 +/- 7.5 ° 320.0 +/- 7.5 ° Lillgrund 120.0 +/- 7.5 ° 180.0 +/- 7.5 ° 222.0 +/- 7.5 ° 255.0 +/- 7.5 °

5. Qualitative comparison of the effect of Park2-features to offshore windfarm data

As an initial test the above primary off-shore wind farm flow cases were used in a comparative study to see the separate effects of the 3 features introduced relative to Park1: a) Consistent formulation; b) Linear wake-superposition; c) Omission of surface reflection. Predictions were made for these flow cases in four steps: by the Park1-model, by hybrid models, where first feature a) and then feature b) are introduced; and by the Park2 model (all features a) b) and c) introduced):

Step Speed-deficit Formulation

Wake superposition Wake Surface- reflection

0 Park1 standard

Inconsistent Quadratic YES

I Park hybrid B Consistent Quadratic YES II Park hybrid C Consistent Linear YES III Park2 Consistent Linear NO

The following wake decay constants were used: Park1 and Park hybrid B: Park1 recommended value (k =0.05); Park hybrid C: the value giving closest agreement (k =0.14); Park2: the value, later found to be recommended (k =0.06). The model predictions were averaged over the same speed- and direction intervals as those used for sampling observations within each flow case. The results are shown below.

Page 14: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

13

5.1 Test results

Figure 6. Horns Rev 1 – Effect of Park2-features a), b) and c), introduced one by one, compared to Park1 and to observations.

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 222 d

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 222 d

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 222 de

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 242 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 242 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 242 deg.

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 50

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 270 deg., Row

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 270 deg., Row

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 270 deg., Row

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 50

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 270 deg., Row

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 270 deg., Row

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 270 deg., Ro

Observations

Park1, k=0.05

Park1-B, k=0.05

Park1-C, k=0.14

Park2, k=0.06

Park1/Park2 Test 8m/s, 222 deg.

Park1/Park2 Test 8m/s, 242 deg.

Park1/Park2 Test 10m/s, 242 deg.

Park1/Park2 Test 12m/s, 222 deg.

Park1/Park2 Test 10m/s, 222 deg.

Park1/Park2 Test 12m/s, 242 deg.

Park1/Park2 Test 8m/s, 270 deg., Row4

Park1/Park2 Test 10m/s, 270 deg., Row4,

Park1/Park2 Test 12m/s, 270 deg., Row4

Park1/Park2 Test 8m/s, 270 deg., Row8

Park1/Park2 Test 10m/s, 270 deg., Row8

Park1/Park2 Test 12m/s, 270 deg., Row8

Page 15: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

14

Figure 7. Nysted – Effect of all Park2-features, a)+b)+c), compared to Park1 and to observations. Only the results of step 0 and step III are shown.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 263 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 263 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 263 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 278 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 278 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 278 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 60

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 320 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 320 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 320 deg.

Observations

Park1, k=0.05

Park2, k=0.06

Page 16: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

15

Figure 8. Lillgrund – Effect of Park2-features. (To continue on the following page.)

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 120 deg.

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 120 deg.

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 120 deg.

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 250

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 180 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 250

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 180 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 180 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 180 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 180 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 180 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 250

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 222 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 222 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 222 deg., Row

Observations

Park1, k=0.05

Park1-B, k=0.05

Park2, k=0.06

180 deg., Row C

180 deg., Row B

180 deg., Row B

180 deg., Row B

180 deg., Row C

180 deg., Row C

222 deg., Row A

222 deg., Row A

222 deg., Row A

Page 17: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

16

Figure 8. Lillgrund – Effect of Park2-feature a) (Park1-B) and features a)+b)+c) (Park2) compared to Park1 and to observations. Only the results of steps 0, I and III are shown.

5.2 Findings from the qualitative comparisons of the effect of the Park2-features

• The consistent speed-deficit formulation in combination with quadratic wake superposition (Park hybrid B) does not represent properly the way the turbine power production decreases downwind into the wind farm. Park hybrid B predicts the power production to drop from the first to the second turbine – but thereafter nearly without any further decrease; this is in contradiction to the observations which show a gradual decrease in turbine power production downwind along a turbine row. When introducing linear speed deficit summation the predicted downwind decrease of turbine power production resembles the observations to a much higher degree.

• The consistent speed-deficit formulation in combination with linear speed-deficit summation rule, but still with wake surface reflection (Park hybrid C), requires a very high wake decay constant value (k=0.14) in order to match the observed power production deficits. However, from eddy-diffusivity arguments (Rathmann, 2017) the k -value should have a clearly lower value like the ones found to match observations when surface reflection is omitted. This – together with the aerodynamic arguments already presented in section 3.1 – supports the decision to omit surface reflection in the Park2 model.

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 222 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 250

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 222 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 222 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 8m/s, 255 deg., Row

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 20

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 10m/s, 255 deg., Ro

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park1/Park2 Test 12m/s, 255 deg., Row

Observations

Park1, k=0.05

Park1-B, k=0.05

Park2, k=0.06

222 deg., Row B

255 deg., Row 5

222 deg., Row B

222 deg., Row B

255 deg., Row 5

255 deg., Row 5

Page 18: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

17

6. Quantitative validation and calibration of Park2 based on offshore wind farms.

This validation and calibration study (Murcia, 2017b) was based on production time series from the offshore wind farms Horns Rev, Nysted, Lillgrund and Anholt. The time series were preprocessed to avoid impact from the situations where one or more turbines were out of operation. The Park2-model was represented by a number of farm-specific look-up tables of total wind farm production as a function of hub-height wind speed and wind direction. The look-up tables covered a k-value range of 0.05 ... 0.16. A so-called Bayesian calibration procedure (Kennedy, 2001; Murcia, 2017a) was applied to deduce the k-value to be recommended. In short, for each single observation of wind farm production a probability density function, PDF, for k was calculated on basis of the look-up tables. By then combining the PDFs for all production observations, taking into account the uncertainty of these observations, a “total” Gaussian-like PDF for k was constructed, resulting in a mean value and a spread of the k-value, see table 7.1 and fig. 9.

Table 8.1. Results for the Bayesian calibration of k. The wind field over the Horns Rev 1, Nysted and Lillgrund wind farms may be assumed rather homogeneous, whereas the wind field over the Anholt wind farm is known to have large gradients due to variations in the distance to nearest coast – gradients not taken into account when producing the look-up tables for the Anholt wind farm. The k-value to recommend for offshore wind farms is therefore based on the results for Horns Rev, Nysted and Lillgrund only, as given in table 8.1. It should be noted that the deduced k-value for Anholt – although differing somewhat from the recommended value – within error bars in fact overlaps with the recommended value.

7. Qualitative Validation of Park2 against offshore wind farm data.

A validation for off-shore with a series of candidate k-values (0.05, 0.06, .., 0.10), including the recommended value, was performed using the observations for the off-shore wind farm flow

Wind farm µ σ Horns Rev 1 0.061 0.005 Nysted 0.057 0.007 Lillgrund 0.064 0.004 Recom-mended value

All 0.06 0.006

Anholt 0.051 0.006

Wake decay constant k

PDF(

k)

Figure 9. PDF of the k-value (Bayesian calibration)

Page 19: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

18

cases listed in section 4. In the model predictions speed- and direction-averaging were applied over the same speed- and direction intervals as those used for sampling observations within each flow-case. The results of this validation are shown in the following plots.

Figure 10. Horns Rev 1. Qualitative validation of Park2 with various k-values.

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 222 deg.

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 222 deg.

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 222 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 242 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 242 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0Re

lativ

e Tu

rbin

e po

wer

Downwind distance [m]

Park2 Test 12 m/s, 242 deg.

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 270 deg., Row4

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 270 deg., Row4

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 270 deg., Row4

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 270 deg., Row8

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 270 deg., Row8

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

-1000 0 1000 2000 3000 4000 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 270 deg., Row8

Observations

Park2, k=0.05

Park2, k=0.06

Park2, k=0.07

Park2, k=0.08

Park2 , k=0.09

Park2, k=0.10

Page 20: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

19

Figure 11. Nysted. Qualitative validation of Park2 with various k-values.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 600

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 263 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 263 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 600

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 263 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 600

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 278 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 278 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 600

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 278 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 320 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 320 deg.

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 320 deg.

Observations

Park2, k=0.05

Park2, k=0.06

Park2, k=0.07

Park2, k=0.08

Park2 , k=0.09

Park2, k=0.10

Page 21: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

20

Figure 12. Lillgrund. Qualitative validation of Park2 with various k-values. (To continue on the following page.)

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 120 deg.

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 120 deg.

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 120 deg.

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 180 deg., Row B

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 180 deg., Row B

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 180 deg., Row B

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 180 deg., Row C

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 180 deg., Row C

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 180 deg., Row C

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 222 deg., Row A

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 222 deg., Row A

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 222 deg., Row A

Observations

Park2, k=0.05

Park2, k=0.06

Park2, k=0.07

Park2, k=0.08

Park2 , k=0.09

Park2, k=0.10

Page 22: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

21

Figure 12. Lillgrund. Qualitative validation of Park2 with various k-values.

7.1 Findings from the qualitative validations. The comparisons of the results from the Park1 model (section 5) and from the Park2 model (this section) to the observations indicate: • The Park2-model with k=0.06 gives an over-all agreement with observations which is at

least as good as for the Park1-model with the recommended k-value of 0.05 for offshore wind farms (figures. 10-12).

• The qualitative validation also reveals that the optimal k-value clearly depends on the wind speed and wind direction. Thus, for a number of the lowest-speed cases – e.g. Horns Rev 222° and 270°, k=0.08 or even 0.09, would give the best fit. For some of the highest speed cases (12 m/s) – e.g. Lillgrund 180° and 255° - k=0.05 would give the best fit. This indicates, that for high wind speeds the model exaggerates the effect of the lower turbine thrust-coefficient on the wake speed deficit, thus leading to an under-prediction of the wake effects. Presumably, the inability of Park2 to model all speed and directional effects is due to the simplifications in the model.

• However, it should be recalled that the qualitative validation only concerns a limited number of wind directions, typically along wind farm “rows”. Therefore the calibration of the over-all k-value cannot be based on these comparisons alone; in addition it is needed to take all available production data into account – as is done in the section 6, “Quantitative validation and calibration based on offshore wind farms”.

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 222 deg., Row B

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 222 deg., Row B

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000 2500

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 222 deg., Row B

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 8m/s, 255 deg., Row 5

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 10m/s, 255 deg., Row 5

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

-500 0 500 1000 1500 2000

Rela

tive

Turb

ine

pow

er

Downwind distance [m]

Park2 Test 12m/s, 255 deg., Row 5

Observations

Park2, k=0.05

Park2, k=0.06

Park2, k=0.07

Park2, k=0.08

Park2 , k=0.09

Park2, k=0.10

Page 23: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

22

8. Calibration of Park2 for on-shore conditions vs. Park1

No proper on-shore wind farm operational data have been readily available for validation and calibration of Park2 for on-shore conditions. Instead, a ‘calibration’ has been undertaken, using AEP-calculations by Park1 for a number of existing or projected on-shore wind farms. Thus a recommended Park2 wake decay constant k for on-shore conditions is found, that gives essentially the same AEP results as those obtained by using the original Park model, Park1, with its on-shore standard k-value (0.075).

14 different on-shore wind farms were used (Mortensen, 2015; Mortensen, 2017):

Wind farm name

Country Rated power Index Wind farm

name Country Rated power

Index

CREYAP 1 GB 14 × 2MW 1 Capel Cynon (6 wind farms)

GB 18 × 2MW 7

CREYAP 2 GB 22 × 1.3MW 2 6 × 3MW 8

Napier ZA 27 × 3.45MW 3 7 × 2MW 9

Jasseines (2 wind farms)

FR 6 × 2MW 4 9 × 2MW 10

4 × 1.8MW 5 4 × 3MW 11

La Ventosa MX 51 × 2MW 6 6 × 0.81MW 12 Vredensburg ZA 34 × 3.6MW 13 Ras Ghareb EG 100 × 3.02MW 14

Table 8.1. Onshore wind farms used for the calibration.

The result of the fitting-procedure to find the matching Park2 k-value is shown in figure 8.1 below. The error bars indicate the k-values where the Park2 production calculation differs ±0.15% from Park1.

The resulting recommended k-value (average value) with associated uncertainty is given in table 8.2.

Figure 8.1. Best-fit wake decay constants for Park2 vs. Park1.

k µ 0.088

σ 0.009

Table 8.2. Resulting recommended k-value with uncertainty.

0.05

0.06

0.07

0.08

0.09

0.1

0.11

0.12

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Wak

e ex

pans

ion

coef

ficie

nt k

Wind Farm index

Page 24: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

23

9. Conclusion The Park wake-model for wind farms has been modified. In the modified Park-model, Park2, we introduce a consistent formulation for the speed-deficit in the wakes. In addition, a more physically based superposition rule is introduced: linear superposition; and for aerodynamic reasons, wake reflection in the surface is omitted. For offshore conditions, the Park2 model was calibrated and evaluated by means of a number of observed production data sets from offshore wind farm flow cases. The calibration resulted in a recommended value for the wake decay constant k. With this recommended k-value Park2 was found to produce predictions at least as close as Park1 to observed offshore wind farm productions. Observed production data from on-shore wind farms for calibration and evaluation were not readily available. Consequently, for on-shore conditions Park2 has been calibrated against Park1-predictions of annual energy production (AEP) for a number of on-shore wind farms, resulting in a recommended value for the wake decay constant k for onshore conditions. The recommended wake decay constant values are given in table 9.1 below:

Windfarm type Offshore Onshore

k µ 0.06 0.09

σ 0.006 0.009

Table 9.1. Recommended wake decay constant values with associated uncertainty.

References [1] Jensen, N.O. (1983): A Note on Wind Generator Interaction. Risø-M-2411 .Risø National

Laboratory, Roskilde, Denmark.

[2] Katic, I., Højstrup, J., Jensen, N.O.(1986): A Simple Model for Cluster Efficiency. EWEA Conference and Exhibition 7-9-October 1986, Rome, Italy, paper C6.

[3] Sanderhoff, P. (1983): Park – Users’ Guide, A PC-program for calculation of wind turbine park performance. Risø-I-668(EN), Risø National Laboratory, Roskilde, Denmark.

[4] Højstrup, J. et al. (1993): Full Scale Measurements in Wind-Turbine Arrays. Nørrekær Enge II. CEC/JOULE. Risø-I-684(EN). Risø National Laboratory, Roskilde, Denmark.

[5] Ott, S., Berg, J. and Nielsen, M. (2011): Linearized CFD Models for Wakes. DTU, Risø National laboratory, Report Risø-R 1772(EN)

[6] Ott, S. and Nielsen, M. (2014): Developments of the offshore wind turbine wake model Fuga. DTU Wind Energy, Report E-0046.

[7] Nygaard, N. (2015): Derivation of the Jensen wake model. DONG Energy. Note. Private communication.

[8] Rathmann O. (2017): Estimation of the Wake Decay Constant from Eddy Diffusivity Theory. Research note, DTU Wind Energy.

Page 25: The Park2 Wake Model - Documentation and Validation€¦ · However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1),

24

[9] Kennedy, M.C., O’Hagan, A. (2001): Bayesian calibration of computer models. Journal of the Royal Statistical Society: Series B (Statistical Methodology), 63(3), 425-464.

[10] Murcia, J.P. et al. (2017a): Uncertainty quantification in wind farm flow models. PhD thesis, DTU Wind Energy.

[11] Murcia, J.P. et al. (2017b): Wake Model Calibration Based On SCADA Data Considering Uncertainty In The Inflow Conditions. Private communication.

[12] Mortensen,N.G. Nielsen, M., and Ejsing Jørgensen, H. (2015). Comparison of Resource and Energy Yield Assessment Procedures 2011-2015: What have we learned and what needs to be done? EWEA 2015, Paris, France, 17-20 November.

[13] Mortensen, N.G. (2017). Personal communication. DTU Wind Energy.

Acknowledgements Wind farm operational data were kindly made available by DONG Energy (now Ørsted) and Vattenfall.