the optimal solution - mozo grau · 0.27 ± 0.43 mm and 0.38 ± 0.51 mm as determined 6 and 12...
TRANSCRIPT
Valladolid, June 2014
Dear Doctors,
We are pleased to introduce our new MTA Catalogue 2014.
Established in Valladolid (Spain) in 1996, Mozo-Grau was created to offer a service by developing, researching, designing and launching new reliable products and solutions for the field of implantological oral surgery, based on the experience of respected professionals.
Quality, innovation, and science are among the fundamental bases on which Mozo Grau sets its activities. Mozo Grau has been audited and certified to be in conformance with local, European and international standards. Its high quality standards demand parts to be produced with specifications accurate to within 10 microns (0.01 mm) and 100% verification of the parts manufactured to pass through a series of rigorous tests before shipping.
As evicence of what science means to Mozo-Grau is our Scientific Summary which gathers over 50 scientific articles on experimental and clinical studies, and a collection of selected clinical cases performed with Mozo Grau dental implants. The best guarantee of Mozo-Grau quality and constant improvement is the research team´s trust and confidence. As for innovation, Mozo Grau is focused in increasing the added value of its production and quality. In this regard, Mozo Grau has launched MG Código Explorer®, a unique numeric code which identifies every single MG dental implant. This code allows doctor and patient to have full traceability and knowledge of the implant. Patients receive their Código Explorer® on a MG Implant Card®, a very comfortable form to carry information everywhere.
Moreover, Mozo Grau has shown its commitment with innovation by designing and developing a new product, the MTA® abutment. This new breakthrough embodies a precise, versatile and functional optimal solution. Detailed information about MTA® will be given in this catalogue.
MG-InHex®
Implantology. Implants. MG INHEX®
INTERNAL CONNECTION11º Morse taper double internal hexagon.
PLATFORM SWITCHINGRespect for the biological principles.
MICROTHREADSReducing marginal bone remodelation.
45º IMPLANT SHOULDERAesthetic soft tissues.
RBM SURFACE TREATMENTPredictable osseointegration. (Success rate 98,2%*)
SURFACE TREATMENT UP TO THEIMPLANT COLLAREvolution of science.
LOADING RESISTANCEStrength of material.
IMPLANT MORPHOLOGYSelf taping, conical apex and, V-shape threads.
IMMEDIATE LOADINGSuitable for the treatment.
* According to the multicentric prospective study published in Official Journal of the Spanish Oral and Maxillofacial Surgery Association (published Sept-Oct 2009). 1,475 implants placed, 654 prostheses over 480 patients, 2.5 years follow up.
p.4
A SOLID BASE: OVER 50 SCIENTIFIC STUDIES AND ARTICLES
MG-InHex®
MICROLEAKAGE OF THE PROSTHETIC ABUTMENT/IMPLANT INTERFACE WITH INTERNAL AND EXTERNAL CONNECTION: IN VITRO STUDY
Carlos Larrucea Verdugo et al. University of Talca, Chile.
Publication: Clinical Oral Implant Research. Article first published online 4 July 2013
Conclusion: “…..the lower levels of microleakage occur in 30N tightened abutments, where, as shown in the photomicrographs, the gap is virtually nonexistent for Morse taper connections and external connections get an almost perfect seal. This may be due to the strict manufacturing criteria found in the analysed elements.”
INFLUENCE OF IMPLANT NECK DESIGN AND IMPLANT-ABUTMENT CONNECTION TYPE ON PERI-IMPLANT HEALTH. RADIOLOGICAL STUDY
Miguel Peñarrocha Diago et al. University of Valencia, Spain.
Publication: Clinical Oral Implant Research. Vol. 24, Issue 11, pages 1192-1200, November 2013
Conclusion: “…..Global mean marginal bone loss with Osseous® was 0.27 ± 0.43 mm and 0.38 ± 0.51 mm as determined 6 and 12 months after prosthetic loading, respectively, whereas in the case of Inhex® was 0.07 ± 0.13 and 0.12 ± 0.17 mm….. Anyway, in both groups, the value obtained were within normal ranges described in the literature”
Implantology. Implants. MG INHEX®
Fig. 1 MG-InHex internal connection photomicrograph. Courtesy of Dr. Carlos Larrucea
Fig. 2 Measurement of peri-implant marginal bone loss. Courtesy of Dr. Miguel Peñarrocha
For more information about the scientific principles that support the MG-InHex implant design, please refer to, among others, the following scientific articles:
p.5
Your Implant, your Code
Every Mozo Grau dental implant is identified with a Código Explorer®, a unique numeric code that will allow you to have full traceability and knowledge of your implant.
John Doe
Código Explorer® ensures 100% traceability of every Mozo Grau implant leading to doctor’s and patient’s peace of mind. Enter your Código Explorer® in Mozo Grau website (www.mozo-grau.com) to download a Certificate of Quality showing full information about your implant.
Patients receive their Código Explorer® on a Mozo Grau Implant Card®, a very comfortable form to carry information everywhere.
IMPLANT CARDTraceability as never seen before
p.6
MG-INHEX
MG-INHEX WITH MTA® ABUTMENT
INSTRUCTIONS FOR USE
IMPRESSION TAKING
Implantology. Implants. MG vial manipulation
Pick up the implant from the vial using the MTA® driver
Remove the MTA® and place the cover screw/healing abutment
Remove the security ringSTEP 1
Remove the security ringSTEP 2
Remove the security ringSTEP 3
Carry safely the implant from the vial to the patient’s mouth
Insert the implant in the alveolus Unscrew the MTA®
Screw the analogue to the MTA® Pour plaster in the impression tray
Cast the model View of the MTA® with the analogue
in the lab model
Place the MTA® and the analogue into the impression coping
Screw the MTA® Place the MTA® impression coping Pour silicone into the impression tray Seat the impression tray in the mouth
Remove the impression tray with the MTA® copings inserted in it. Unscrew the MTA®
p.8
Implants
Implantology. Implants. MTA
MG-INHEX
REF.
23303708
23303710
23303711
23303713
23303715
23305001
DESCRIPTION
3.75 x 8 mm STD MG-INHEX Implant
3.75 x 10 mm STD MG-INHEX Implant
3.75 x 11.5 mm STD MG-INHEX Implant
3.75 x 13 mm STD MG-INHEX Implant
3.75 x 15 mm STD MG-INHEX Implant
MG-INHEX STD Cover screw*Do not tighten at torque values higher than 10 Ncm
3.75 mm STANDARD MG-INHEX WITH MTA®
- Double Internal Hexagon- Implant Platform: 2.80 mm- Implant Diameter: 3.75 mm- Ø Internal thread: 1.6 mm- Internal Morse Cone 11º- Material: Grade IV Commercially Pure Titanium- “No touch” sterile package
- MTA® cuff height: 2.0 mm
DRILLING SEQUENCE
Bone
Tap
(for v
ery
corti
cal
bone
s)
Loca
tor d
rill
2.0
mm
3.0
mm
3.3
mm
Profi
le D
rill
3.5
mm
har
d bo
ne d
rill
23202526 Prosthetic screw
Platform identification
Std Max
MG-INHEX with MTA Package includes:- MG-INHEX® implant- MTA® abutment- MTA® impression coping- Cover screw- Prosthetic screw
A standard drilling sequence will be needed and the 3.3 mm drill will be the final one to be used
(recommended drilling speed: 800-1000 rpm). It is suggested to use the profile drill at 800 rpm. Being the
implant self-tapping, on very cortical bones (symphysis area) it is recommended to use the drills for hard
bones, and, if considered necessary, use the 3.75 mm bone tap to avoid overheating the bone and to
facilitate the implant insertion.
The use of copious internal irrigation is suggested, too.
It is recommended to place the implants at torque values between 35-45 Ncm.
800-1000 rpm 800 rpm 800-1000 rpm 15 rpm
p.9
Implants
Implantology. Implants. MTA
MG-INHEX4.25 mm STANDARD MG-INHEX WITH MTA®
REF.
23304208
23304210
23304211
23304213
23304215
23305001
DESCRIPTION
4.25 x 8 mm STD MG-INHEX Implant
4.25 x 10 mm STD MG-INHEX Implant
4.25 x 11.5 mm STD MG-INHEX Implant
4.25 x 13 mm STD MG-INHEX Implant
4.25 x 15 mm STD MG-INHEX Implant
MG-INHEX STD Cover screw*Do not tighten at torque values higher than 10 Ncm
- Double internal hexagon- Implant Platform: 2.80 mm- Implant Diameter: 4.25 mm- Ø Internal Thread: 1.6 mm- Internal Morse Cone 11º- Material: Grade IV Commercially Pure Titanium- “No touch” sterile package- MTA® height: 2.0 mm
DRILLING SEQUENCE
Bone
Tap
(for v
ery
corti
cal
bone
s)
Loca
tor d
rill
2.0
mm
3.0
mm
3.3
mm
3.8
mm
Profi
le D
rill
4.0
mm
har
d bo
ne d
rill
MG-INHEX
23202526 Prosthetic screw
Platform identification
Std Max
MG-INHEX with MTA Package includes:- MG-INHEX® implant- MTA® abutment- MTA® impression coping- Cover screw- Prosthetic screw
A standard drilling sequence will be needed and the 3.8 mm drill will be the final one to be used
(recommended drilling speed: 800-1000 rpm). It is suggested to use the profile drill at 800 rpm. Being
the implant self-tapping, on very cortical bones (symphysis area) it is recommended to use the drills for
hard bones, and, if considered necessary, use the 4.25 mm bone tap to avoid overheating the bone and
to facilitate the implant insertion.
The use of copious internal irrigation is suggested, too.
It is recommended to place the implants at torque values between 35-45 Ncm.
800-1000 rpm 800 rpm 800-1000 rpm 15 rpm
p.1
0
MG-INHEX
REF.
23305009
23305010
23305011
23305013
23305015
23305000
DESCRIPTION
5.0 x 9 mm MAXI MG-INHEX Implant
5.0 x 10 mm MAXI MG-INHEX Implant
5.0 x 11.5 mm MAXI MG-INHEX Implant
5.0 x 13 mm MAXI MG-INHEX Implant
5.0 x 15 mm MAXI MG-INHEX Implant
MG-INHEX MAXI Cover screw*Do not tighten at torque values higher than 10 Ncm
- Double Internal Hexagon- Implant Platform: 3.80 mm- Implant Diameter: 5.0 mm- Ø Internal Thread: 2.0 mm- Internal Morse Cone 11º- Material: Grade IV Commercially Pure Titanium- “No touch” sterile package- MTA® height: 2.0 mm
5.0 mm MAXI MG-INHEX WITH MTA®
DRILLING SEQUENCE
Bone
Tap
(for v
ery
corti
cal
bone
s)
Loca
tor d
rill
2.0
mm
3.0
mm
3.3
mm
3.8
mm
4.3
mm
4.7
mm
Profi
le D
rill
4.9
mm
har
d bo
ne d
rill
Implants
Implantology. Implants. MTA
23205025 Prosthetic screw
Platform identification
Std Max
MG-INHEX with MTA Package includes:- MG-INHEX® implant- MTA® abutment- MTA® impression coping- Cover screw- Prosthetic screw
A standard drilling sequence will be needed and the 4.7 mm drill will be the final one to be used
(recommended drilling speed: 800-1000 rpm). Drills wider than 4.3 mm are recommended to be used
at 400 rpm. It is suggested to use the profile drill at 800 rpm. Being the implant self-tapping, on very
cortical bones (symphysis area) it is recommended to use the drills for hard bones, and, if considered
necessary, use the 5.0 mm bone tap to avoid overheating the bone and to facilitate the implant insertion.
The use of copious internal irrigation is suggested, too.
It is recommended to place the implants at torque values between 35-45 Ncm.
800-1000 rpm 400 rpm 800 rpm 400 rpm 15 rpm
p.1
1
Implantology. Implants. MTA and MG INHEX®
MTA® ABUTMENT
REF.
23307010
23307051
DESCRIPTION
MTA® for MG-INHEX STD
MTA® for MG-INHEX MAXI
MTA® IMPRESSION COPING
23305600 Impression coping for MTA® STD-MAXI
MTA® SURGICAL INSTRUMENTS
23309021
23309121
23308000
23308001
MTA® driver
MTA® adapter
Open-end wrench adapter
Handle for adapters
23309131
23309141
MTA® hex adapter
MTA® square adapter
Prosthetic System MG-InHex®
PRODUCT STD MAXI AESTHETIC HEX NON HEX REMARKS
Healing abutment
Impression coping
2-7 mm (3-7 mm Aesthetic)
Also available long imp. cop.
Analogue
Titanium UCLA
Gold base
Abutment for zirconium
Prepable 0-4 mm (Hex) 1-4 mm(Non-Hex) 3-4 mm (Aesthetic)
Compatible with CEREC 3DSIRONA®
Angled 1-5 mm
MTA® AND IMPRESSION COPING
MTA® cuff height: 2 mm
Impression coping for closed tray only
SURGICAL INSTRUMENT
- MTA® driver to place MTA® implant with C/A.
- MTA® adapters to place implant with squared
and hex wrenches
- Use handle and adapters to hold either
implant mount or MTA® while they are
unscrewed. Suitable for cases with little
primary stability.
p.1
2
Implantology. Implants. MG INHEX® .
PRODUCT STD MAXI AESTHETIC HEX NON HEX REMARKS
Ball
Ball analogue
Locator 1-5 mm
1-5.5 mm
Castable Post
Titanium Post
Analogue
Impression coping
17º Angled tapered abut. 2-4 mm
Rotational castable post
Rotational titanium post
17º Analogue
Impression coping
Prepable 2 mm height only
Castable UCLA
Titanium UCLA
Castable post for tapered abut. 10º and 30º
Titanium post for tapered abut. 10º and 30º
Castable post for angled tapered abutment 17º
17º
TAPERED ABUTMENT
17º ANGLED TAPERED ABUTMENT
TEMPORARY ABUTMENT
10º/30º Tapered abut. 10º (0-5 mm) 30º (1-5 mm)
Titanium post for angled tapered abutment
p.1
3
Surgical Material. MTA
MTA® Surgical Kit
MTA® SURGICAL KIT
REF.
15400005
DESCRIPTION
MTA® Surgical Kit
Locator drill
2.0 mm twist drill.
3.0 mm conical drill.
3.3 mm conical drill
3.8 mm conical drill
4.3 mm conical drill
4.7 mm conical drill
3.3 mm profile drill
3.75 mm profile drill
4.25 mm profile drill
4.0 mm conical drill. Hard bone
4.9 mm conical drill. Hard bone
Paralleling pins (3 units)
MG-INHEX Medium Mini Implant mount
MG-INHEX Short Std Implant mount
MG-INHEX Long Maxi Implant mount
1.25 mm long hex screwdriver
Drill extender
STD MG-INHEX depth gauge
16 mm ratchet wrench extender
Hex Hand wrench
C/A implant mount driver
Square adapter
SPECIFIC MATERIAL FOR MTA:
Hexagonal adapter
Driver
Open-end wrench adapter
Handle for adapters
Adapter
5.0 mm profile drill
3.2 mm conical drill. Hard bone
3.5 mm conical drill. Hard bone
p.1
4
International Quality Certificates
CE Marking
COLOMBIA
TAIWAN
VENEZUELA MEXICO
CHINARUSSIA
ISO 13485: 2012 ISO 9001: 2008
www.mozo-grau.com
C/ Santiago López González, 7 · 47197 Valladolid · Spain Tel. +34 983 211 312 · Fax +34 983 304 021 · [email protected]
HEADQUARTERS
ul. Grójecka 22/24 lok. 52, 02-301 Warsaw · Poland tel./fax: +48 22 658 41 21 · [email protected]
DISTRIBUTOR
MG
201
4 -
MTA
jun
01
Follow us:
CHILE CHINA COLOMBIA IRAN ITALY MEXICO POLANDPORTUGAL RUSSIA SPAIN TAIWAN VENEZUELA