the opportunities and limitations of electromagnetic field ... · summary emf requires no or low...
TRANSCRIPT
![Page 1: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/1.jpg)
The Opportunities and Limitations of
Electromagnetic Field (EMF) for Scaling
Control
Pei Xu, Wenbin Jiang, Xuesong Xu, Juliano Aleida, Lu
Lin, Huiyao Wang, Randy Shaw
MSSC Summit, February 27, 2020
![Page 2: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/2.jpg)
Scaling in Water Systems
![Page 3: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/3.jpg)
Scaling in Water Systems
➢ Loss in performance and economics
➢ Chemical treatment
➢ Addition of scale inhibitors
➢ Chemical softening
➢ Ion-exchange
➢ Chemical cleaning
➢ Handling, storage, and management of chemicals
➢ Environmental and health impacts
![Page 4: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/4.jpg)
Non-chemical Scaling Control –
Electromagnetic Field (EMF)
(a) Permanent magnets (b) Solenoid coil
(c) Schematic representations of wavesforms
![Page 5: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/5.jpg)
Pilot Testing of EMF on RO Scaling Control during
Brackish Groundwater Desalination at BGNDRF
◼ Two types of EMF devices tested
HydroFLOW: induce an electric signal of ±150 kHz in the liquid
inside of a pipe on which they are installed. A specialized
transducer connected to a ring of ferrites performs the electric
induction
![Page 6: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/6.jpg)
Pilot Testing of EMF on RO Scaling Control during
Brackish Groundwater Desalination at BGNDRF
◼ Two types of EMF devices
tested
HydroFLOW: HS48 was
installed in the metal pipeline
before the cartridge filter and
S38 was installed in the inlet
of the RO vessel.
![Page 7: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/7.jpg)
Pilot Testing of EMF on RO Scaling Control during
Brackish Groundwater Desalination at BGNDRF
◼ Two types of EMF devices tested
Eco1st Separation Enhancer: an inline fluid ionization system
using electrochemical ionization principles. It induces EMF into the
flowing fluid and discharges electrons from the molecules exist in
the water. The free electrons will then be routed and drawn to a
dedicated earth ground.
![Page 8: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/8.jpg)
Pilot Testing of EMF on RO Scaling Control during
Brackish Groundwater Desalination at BGNDRF
◼ Two types of EMF devices tested
Eco1st Separation Enhancer: installed before the cartridge filter of
a 2-stage RO system.
![Page 9: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/9.jpg)
Feed Water Quality
◼ Two types of groundwater used
Water quality parameter Unit Well 1 Well 2
Temperature ℃ 21.3 27.0
pH pH unit 7.74 7.17
Electrical conductivity µmhos/cm 1840 6440
Total dissolved solids mg/L 1260 5850
Langelier Saturation Index SI 0.44 0.55
Total alkalinity (as CaCO3) mg/L 147 244
Chloride mg/L 36 521
Sulfate mg/L 723 3200
Total hardness (as CaCO3) mg/L 233 2550
Calcium mg/L 66 501
Magnesium mg/L 16 316
Potassium mg/L 4.7 2.1
Silicon dioxide mg/L 21.5 20.8
Sodium mg/L 305 650
Strontium mg/L 1.9 8.1
![Page 10: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/10.jpg)
RO Scaling Simulation
◼ Scaling indices for the RO system based on the ROSA
modeling: Well 2 water at 50% water recovery
Parameter Feed Water Concentrate
Langelier Saturation Index 1.07 1.80
Stiff & Davis Stability Index 0.69 1.16
Ionic Strength (Molar) 0.14 0.29
CaSO4 (%Saturation) 105 238
BaSO4 (%Saturation) 174 352
SrSO4 (%Saturation) 71 150
![Page 11: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/11.jpg)
Pilot Testing Results - HydroFLOW
◼ Membrane flux decline during 150 hr desalination of Well
2 water at 50% water recovery without antiscalant
0
10
20
30
40
70 90 110 130 150
Wate
r perm
eabili
ty d
eclin
e r
ate
(%
)
Operating time (h)
Phase 1 without EMF
Phase 2 with EMF 35%
![Page 12: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/12.jpg)
Pilot Testing Results - HydroFLOW
◼ EMF + Hydraulic flushing partially restore membrane
performance
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0
10
20
30
40
50
60
70
80
90
100
0 100 200 300 400 500 600 700 800 900
Sp
ecific
w
ate
r flu
x a
t 2
5 o
C (
gfd
/psi)
Wa
ter
reco
ve
ry (%
)
Operating time (hours)
Phase 2 Water recovery
Phase 2 Specific water flux
Hydraulic flush
![Page 13: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/13.jpg)
Pilot Testing Results - HydroFLOW
◼ Product Water Quality
60%
80%
100%
Na+ K+ Mg2+ Ca2+ Cl- SO42- Conductivity
Ions r
em
ove
al
No EMF With EMF
![Page 14: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/14.jpg)
Pilot Testing Results - HydroFLOW
0
2000
4000
6000
0 1 2 3 4 5 6 7
Co
un
ts
Kev
P1E1-DI
C
N
O
Si
Al
FMg
S
NaK Ca Fe
(a)
0
4000
8000
12000
16000
0 1 2 3 4 5 6 7
Cou
nts
Kev
C
N
O SiAl
P1E3-DI
S Ca
(b)
0
4000
8000
12000
0 1 2 3 4 5 6 7
Cou
nts
Kev
P2E3-DIC
N
OSi
AlF
SMgNa Ca
(d)
0
4000
8000
12000
0 1 2 3 4 5 6 7
Cou
nts
Kev
P2E1-DIC
N
O Si
AlF
S
MgNa FeCaK
(c)
No EMF Lead
No EMF End
With EMF End
With EMF Lead
No EMF
With EMF
![Page 15: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/15.jpg)
Pilot Testing Results
◼ Clean up the scales in the water pipelines
![Page 16: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/16.jpg)
Bench-Scale Testing
➢ Impact of EMF on RO membrane fouling and
scaling during treatment of secondary effluent and
brackish water
Schematic Diagram
![Page 17: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/17.jpg)
Bench Testing – Secondary Effluent
➢ EMF + hydraulic flushing can control membrane fouling
0
5
10
15
20
0 10 20
Flu
x d
eclin
e, %
Time, h
EMF + HD
![Page 18: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/18.jpg)
Bench Testing – Secondary Effluent
➢ EMF + hydraulic flushing can control membrane fouling
0
5
10
15
20
0 10 20
Flu
x d
eclin
e, %
Time, h
Hydraulic clean EMF + HD
![Page 19: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/19.jpg)
Factors Affecting EMF Effectiveness
![Page 20: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/20.jpg)
Summary
➢ EMF requires no or low energy.
➢ EMF pretreatment can significantly reduce chemical costs,
energy, and negative environmental impacts of chemical
treatment.
➢ Reduce initial membrane scaling and fouling by 30-40%.
➢ Periodic hydraulic flushing + EMF can recover RO
membrane performance by removing the foulants loosely
accumulated on membrane surface and flow channels.
➢ Work at moderate water recovery.
➢ Promote bulk precipitation, spacer design is critical.
![Page 21: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/21.jpg)
Future work
➢ Evaluate the combination of EMF with 3D printed
open flow channel RO membranes to achieve
high recovery
![Page 22: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/22.jpg)
Future work
➢ Molecular dynamics simulations to gain insights
into how the applied electromagnetic fields effect
the motions of ions in the fluid. Develop methods
to compute polarizabilities, net atomic charges,
and force-field simulations on molecular
interactions between ions and membranes.
➢ Sensors to monitor the induction time and particle
motions.
![Page 23: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/23.jpg)
Acknowledgements
➢ Bureau of Reclamation
➢BGNDRF
➢DWPR funding
➢ El Paso Water
➢ AquaMembranes
➢ HydroFLOW
➢ Eco1st
![Page 24: The Opportunities and Limitations of Electromagnetic Field ... · Summary EMF requires no or low energy. EMF pretreatment can significantly reduce chemical costs, energy, and negative](https://reader034.vdocuments.us/reader034/viewer/2022042202/5ea2a317919cd4143f39bf38/html5/thumbnails/24.jpg)
Pei Xu: [email protected]