The ODS Alloy High Temperature Heat Exchanger and Associated Work
Fred Starr : Project Leader and Senior Principal ScientistBritish Gas 1966-96
![Page 2: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/2.jpg)
Presentation
The ODS Heat Exchanger Programme and how it came about
Some of the results of the long term testing
Future possibilities for ODS alloys and what developments are needed
![Page 3: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/3.jpg)
The Closed Cycle Gas Turbine DemonstratorColeshill Works: English Midlands 1996
ODS Heateris in
Furnace Box
![Page 4: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/4.jpg)
In 1986 GH Gibson: Assistant Director, London Research Station said
“LRS on behalf of British Gas needs to develop more advanced power and energy conversion
concepts”
F.Starr : Senor High Temperature Materials Scientist said
“Let us use ODS alloys to improve the Closed Cycle Gas Turbine and the Stirling Engine”
Yes We Can!
Build Equipment, not paper concepts !
Obtain ReliableLong Term Engineering
Data
Get Help From
Outside Experts
![Page 5: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/5.jpg)
Steam TurbineBoiler
Water Pump Condenser
Steam Plant and Gas Turbine Closed Cycles
Steam PlantWorking Fluid
= Water
Moderate Temperatures
High Pressures
Heater High TemperatureTurbine
CoolerCompressor
Closed CycleWorking Fluid= Air, Helium
High TemperaturesModeratePressures
![Page 6: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/6.jpg)
Grev Gibson: Assistant DirectorFred Starr : Project LeaderClosed Cycle Gas Turbine Programme
![Page 7: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/7.jpg)
F Starr: Shift Engineer Hitchin Steam Reforming Plant 1967
High Temperature Furnaces
![Page 8: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/8.jpg)
Investigating a Fired Heater Failure in 1972
![Page 9: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/9.jpg)
Micro Stirling Engines For
In-House Cogeneration1987-96
High Temperature Heat Exchangers were Vital !
![Page 10: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/10.jpg)
The Closed Cycle Gas Turbine Demonstrator1987-1996
Main Aims • To lead to a 100 MW generating plant with an efficiency of 60%• To identify the key technical challenges
Uncooled 1100°C Helium TurbineHigh Effectiveness Pressurised Recuperator
High Temperature ODS Heater
Heater Requirements : 1100ºC Outlet, 30-50 bar pressure, 1MW heat input
Alloy Requirements: 25-40 MPa at 1150ºC for 100000 hrsNo oxidation or corrosion
![Page 11: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/11.jpg)
Basic Closed Cycle Gas Turbine Loop
High Temperature Heat Exchanger
Recuperator
Intercooled Compressors Turbines
Efficiency : c.30% at TINLET of 700ºC but 60% at TINLET of 1100ºC
![Page 12: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/12.jpg)
System Layout for Demonstrator
![Page 13: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/13.jpg)
The Closed Cycle Part of the Demonstrator
![Page 14: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/14.jpg)
Original Idea for Heater : Cage Type
Tubes symmetricallyarranged
round burner
![Page 15: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/15.jpg)
Late Design Change to Harp Type
Location of the Two Floor BurnersA very bad design feature
Top header OfftakeBad
Bad design feature
![Page 16: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/16.jpg)
Dr Quentin Mabbut : Responsible for getting the Demonstrator built
And for making the tubes in Belgium!
![Page 17: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/17.jpg)
Heater Box Before Piping Up Heater When Operating
Convector section not in place
![Page 18: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/18.jpg)
800ºC Flowfrom Convector
to ODS Heater
Piping system was extremely complex because of ;
Bypass systems to reduce inlet temperature to turbocharger
Cocurrent flow design of heater
![Page 19: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/19.jpg)
Pipe to Turbocharger
![Page 20: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/20.jpg)
START OF CONSTRUCTION OF HARP TYPE HEATER
ODS Tubes
Transition Joint
![Page 21: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/21.jpg)
ODS Heater Being Shipped to Site
ODS Tubes
Cast Stainless Headers
![Page 22: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/22.jpg)
Insulated Bottom Header
Transition Joints
Direction of
Flow
Inside of Furnace Box
Burners on
Heater Bottom
![Page 23: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/23.jpg)
Failure occurred very rapidlyin end ODS tubes:
• Poor temperature and heat distribution
• Tubes did not have bends to compensate for thermal expansion
• Very limited short term tensile and creep ductility
End Tube had to be Capped off Because of Tube Failure
![Page 24: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/24.jpg)
Close Up of Tube Failures
Another Low DuctilityFailure?
![Page 25: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/25.jpg)
Alloy Strength Issues
Tube strength was well below target(Failure in less than one hour at 30 MPa
at 1150ºC)
Concept re-designed to run to run at 9 bar
![Page 26: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/26.jpg)
Limited creep ductility
![Page 27: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/27.jpg)
Long term exposure leads to growth of porosity
In this case porosity maybe nucleated by
Kirkendall Vacancies from Oxidation
However any disruption of the microstructure which leads to
increases in sites for nucleationresults in porosity formation
![Page 28: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/28.jpg)
![Page 29: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/29.jpg)
Initial Concern about Oxidation was Spalling
Begins here
![Page 30: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/30.jpg)
Generally good oxide adherence after 6000 Hoursat 1150-1200ºC
Bright spots are where local spalling has occurred
![Page 31: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/31.jpg)
Sudden Onslaught of Breakaway Oxidation
50-100 micron alumina scale cracks in patches
Subscale is of a chromiatype
Massive Breakaway Oxidation
![Page 32: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/32.jpg)
Another View of Breakaway
![Page 33: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/33.jpg)
Breakaway on MA956 after
2500 hours at 1200ºC
Time to Breakaway is determined by:• Temperature • Free aluminium content• Tube thickness• Spallation• Local Geometry
![Page 34: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/34.jpg)
Exploded Welded Joints
ODM 751
Cast Stainless Steel
![Page 35: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/35.jpg)
Type of Joint Bonding
ODM 751
Low Carbon T57 Cast Stainless: (Fe -33.7Ni -23.4 Cr – 0.8Nb -0.11C)
![Page 36: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/36.jpg)
Formation of Diffusion Zone after 100 hrs at 1150ºC
Paralloy Cast T 57 Stainless Steel
ODM 751
Cracking is probably caused by oxide jackingand thermal expansion mismatch
Extensive nitridationin diffusion zone
{
![Page 37: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/37.jpg)
Extensive porosity formationassociated with Ni diffusion into ODM 751
![Page 38: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/38.jpg)
Nickel Aluminide Formation in Diffusion Zone
![Page 39: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/39.jpg)
Three Manufacturing Routes: What Did We Learn?
H. Wiggins MA956
Fine grain size is completely uselessThe transition weld problem
Dourmetal : ODM 331 and 751
Coarse onion skin grains needed for tubingStress sensitivity is highBreakaway corrosion
Plansee 2000
Uniform working process to ensure uniform recrystallisatonOxidation and nitridation and porosity formation
![Page 40: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/40.jpg)
ODS Alumina Formers Development Targets and Commercial Prospects
• Reduce Directionality• Reduce Spalling• Lengthen Time to Breakaway
Plus 1100ºC Below 1050º
“Clean” Environments Only
• Reduce Directionality• Improve Strength
Tubing a Priority Pipe, Tubing, Sheet
Welding, Joining and Safety Factors
“Topping” and “CCS”Power Generation
Cycles
Gas Heated ReformerRecuperative Gas Turbines
Radial MicroturbinesExhaust Valves
COSTS AND COST EFFECTIVENESS
![Page 41: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/41.jpg)
Gas Heated Reformer for Hydrogen Productionand Natural Gas CCS
![Page 42: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/42.jpg)
Type 347 Stainless Steel Recuperator
Gas Turbine
Solar Mercury 50 Recuperative Gas Turbine
Alternator Shaft
![Page 43: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/43.jpg)
• Lowest Possible Density .
• Tensile Strength of 250 MPa at 750-800ºC
• Wear Resistance
Lightweight Exhaust Valves for Auto Engine Efficiency
![Page 44: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/44.jpg)
Closed Cycle Developments?
Improvements in CCGTs undermine prospects for simple closed cycle
But CO2 capture is a problem for CCGTs
High excess air 200-300% results in dilution of CO2
Excess air in closed cycle heater is 20%
But probably best to use closed cycle as part of an advancedsteam cycle
![Page 45: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/45.jpg)
1050-1100ºCClosed Cycle
without air
preheater
Flue Gas at 700ºCto
HRSG Boilerand
Superheater
Power from Steam Turbines
Power from Closed Cycle Gas Turbines
Carbon Capture on Ambient Temperature Flue Gas
CCS Closed Cycle Concept
![Page 46: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/46.jpg)
Range for ODM 751 ?
![Page 47: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/47.jpg)
Estimated Life v . Temperature at 30 M Pa Stress( based on 1150°C/1 hour data !!!!!!!!)
-2
-1
0
1
2
3
4
5
6
7
8
900 950 1000 1050 1100 1150 1200
Temperature °C
Log
Life
Hou
rs
Best Cast Stainless
LM Parameter = 40
LM Parameter = 20
![Page 48: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/48.jpg)
Conclusions
By building a heat exchanger we took ODS alloys right to the borderline
In so doing, we put “numbers” to the academic issues of:
• The effect of directionality on strength• Oxidation rates and breakaway• Porosity
Highlighted the need for long term testing of joining techniques
What Now? (As Barack Obama is saying)
Better and less costly materials, more data, better joining methods• Better ductility, at room temperature, and in creep • Effect of bending and cold working on properties• Safety factors of directional materials with a high
stress sensitivity
![Page 49: The ODS Alloy High Temperature Heat Exchanger and](https://reader030.vdocuments.us/reader030/viewer/2022012502/617b5068d5326828dd1c4a0b/html5/thumbnails/49.jpg)
Thank You
Especially to :
Bimal Kad
Peter Torterelli