The Heat Stop. 25 August 2003 ATST CoDR. Dr. Nathan Dalrymple Air Force Research Laboratory Space Vehicles Directorate. Heat Stop. Function: first field stop, blocks most light from proceeding to M2 and subsequent optics Location: prime focus. Mode 1: On-disc. Mode 2: Corona. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: The Heat Stop

The Heat Stop

25 August 2003 ATST CoDR Dr. Nathan Dalrymple

Air Force Research LaboratorySpace Vehicles Directorate

Page 2: The Heat Stop

Heat Stop

• Function: first field stop, blocks most light from proceeding to M2 and subsequent optics

• Location: prime focus

Page 3: The Heat Stop

Mode 1: On-discMode 2: Corona

Mode 3: Near-limb corona

Requirements

1. Block occulted field (OF) over approximately 82 arcmin circular to allow 2.5 Rs off-pointing

2. Pass field of view (FOV)

Page 4: The Heat Stop

Requirements (cont.)

3. Fast limb tracking Mode 3: occulter must block limb light while compensating for telescope shake and seeing

4. Remove irradiance load (up to 2.5 MW/m2)

Page 5: The Heat Stop

Requirements (cont.)

5. Minimize self-induced seeinga. Experiments and scaling laws for small hot objects

near M2 indicate insensitivity for seeing-limited observations (Beckers, Zago)

b. Bottom line: surface temperature must be within some 10 ˚C of ambient air temperature

Error Budget:DL: 10 nm @ 500 nmSL: 0.03 arcsec @ 1600 nmC: 0.03 arcsec @ 1000 nm

Plumes not good for AO system

Refs: Beckers, J. M. and Melnick, J. "Effects of heat sources in the telescope beam on astronomical image quality". Proc. SPIE 2199, 478-480 (1994) Zago, L. "Engineering handbook for local and dome seeing". Proc. SPIE 2871, 726-736 (1997)

Page 6: The Heat Stop

Concept: Tilted Flat Plate

Flat plate heat stop(reflective)

Most light reflectsonto dome interior

Tilt angle fromgut ray: 19.5˚

Plume suction

Page 7: The Heat Stop

Concept Detail 1

Heat stop face

Air crossflow directors (blower and getter)

Ceramic periphery shield

Air and liquid coolant lines

Normal startup: 1. Point to Sun (put Sun somewhere in OF)2. Open mirror covers

Page 8: The Heat Stop

Heat Stop Detail

Tilted flat plate

Parts are furnace-brazed together

Reflector (GlidCop)

Jet plate/intakemanifold (SS)

Exit manifold (SS)Mount plate (SS)

Fast occulter insert

Mount (steel)

Page 9: The Heat Stop

Heat Stop, Exploded

Tilted flat plate

Reflector (GlidCop)

Jet plate/intakemanifold (SS)

Exit manifold (SS)

Mount plate (SS)

Parts are furnace-brazed together

Mount (steel)

Fast occulter insert

Page 10: The Heat Stop

Internal Flow Concept

Coolant jets

Jet exhaust tubes

Reflectivesurface

Coolant inlet

Coolant outlet

Fast occultermount

Page 11: The Heat Stop

External Flow Concept

Main coolant inletCoolant exit

Inlet manifold

Sector coolant inlets•Flowmeters•Thermometers•Pressure gauges

Page 12: The Heat Stop

Mounting Arrangement

Ceramic shield

Flow meters

Page 13: The Heat Stop

Crossflow Directors

Page 14: The Heat Stop

Plumbing and Ductwork

Page 15: The Heat Stop

Interface With OSS

Page 16: The Heat Stop

Flow Loop

Q is approximately 1700 W (peak)Not shown: accumulator, safety valves, etc.

.

Page 17: The Heat Stop

Safety Systems

• Passive-closing mirror covers• Accumulators hold emergency coolant reserve• Pressure-relief valves• Instrumentation

Surface temperatureFlowrateCoolant temperatureCoolant pressure

Page 18: The Heat Stop

Reflector Plate Thermal Performance

14.1˚ (sides of cone)

5.4˚ (bottom of cone)

33.6˚ (top of cone)

NASTRAN axisymmetric model results:h = 15 kW/m2-KTc = Te – 10 Kq˝abs = 265 kW/m2.

Page 19: The Heat Stop

Detail of Heat Stop Aperture

NASTRAN axisymmetric model results:h = 15 kW/m2-KTc = Te – 10 Kq´´abs = 265 kW/m2.

Hot spot is 17˚ hotter than coolant, 7˚ hotter than ambient

Occulting edge is not the hottest spot!

Page 20: The Heat Stop

Thermal Performance of Flow System

VFR for h = 15 kW/m^2 K

0.00

20.00

40.00

60.00

80.00

100.00

120.00

245 265 285 305 325

Temperature (K)

Volume Flow Rate (gpm)

VFR (gpm) 50%

VFR (gpm) 40%

Ethylene glycol/water solutions

Page 21: The Heat Stop

Low Temperature Thermal Performance

Heat Transfer Coefficient, 253 K

0.00

2000.00

4000.00

6000.00

8000.00

10000.00

12000.00

14000.00

16000.00

0 50 100 150

Volume Flow Rate (gpm)

h (W/m^2 K)

Syltherm HF

Syltherm XLT

Dowtherm 4000 40%

Dowtherm 4000 50%

Dowtherm J

Page 22: The Heat Stop

Low Temperature Pump Power

Power Curve (2,3 in), Dynalene 20 HC, 253 K

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

0 50 100 150

Volume Flow Rate (gpm)

Power (hp)

P 2 in tot (hp)

P 3 in tot (hp)

P 1.5 in tot (hp)

Page 23: The Heat Stop

Survival

Next Steps:• Reflector lifetime with partial cooling (boiling)• Normal operating stresses

• NASTRAN structural modeling• Full-scale test at NREL

Reflector will last about 30 sec with no cooling