the fusion of imaging technologies introducing. spectralis is more than resolution … time domain...
TRANSCRIPT
![Page 1: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/1.jpg)
The Fusion of Imaging TechnologiesThe Fusion of Imaging Technologies
INTRODUCINGINTRODUCING
![Page 2: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/2.jpg)
Spectralis is more than resolution …
Time Domain OCT SPECTRALIS
![Page 3: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/3.jpg)
Spectralis is more than fast …
0 10000 20000 30000 40000
Time Domain
"3D OCT"
"FD OCT"
"HD OCT"
Spectralis 40 kHz = 100x Faster than time domain OCT
![Page 4: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/4.jpg)
Spectralis is more then SD-OCT… Dual laser scanning system for
simultaneous imaging: Confocal Scanning Laser Ophthalmoscope (cSLO)
with up to 5 imaging modes: IR, FA, ICGA, AF, Red-free
Spectral Domain Optical Coherence Tomograph (SD-OCT)
Eye tracking: cSLO recognizes eye movements and guides
SD-OCT scanner to follow Allows repeat scans at exact same location
![Page 5: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/5.jpg)
Spectralis is more than one view …ICGA Polypoidal Lesion
![Page 6: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/6.jpg)
Spectralis is more than 3D …
![Page 7: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/7.jpg)
Spectralis is knowing locationCross section scanReference scan
Eye MovementThe reference image tracks eye movement, and the cross section is moved to match
EYE TRACKING
![Page 8: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/8.jpg)
Spectralis Tracks Change Over Time
Exam 1 Exam 2
Real-time alignmentCross section
scanned at same location
• Real-time alignmentCross section scanReference scan
EYE TRACKING• Accurate change measurement
![Page 9: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/9.jpg)
Heidelberg Noise Reduction Technology
Multiple images are captured at the same location
“Noise” is identified as points not common to the set of images
The noise is filtered from the final image
Image 1 Image 2
Heidelberg Noise Reduction Technology produces high resolution, high contrast images with less “speckle”.
![Page 10: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/10.jpg)
Simultaneous Imaging with Eye Tracking
![Page 11: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/11.jpg)
What’s wrong with the old OCT?
Hidden artifact – structure may be different than presented
Not simultaneous – B-Scan may be in different location than reference image
No eye tracking – Not good for LASIK, not good for diagnostics
(S)low resolution – Layers hard to identify for computer algorithms
![Page 12: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/12.jpg)
Old OCT Does Not Stop Eye Movement
While Time Domain OCT scans, the eye keeps moving
The black line is the camera’s perspective
The white line is the actual scan path
“Tracking the Optic Nervehead in OCT Video…” Koozekanani, et al, 2003
© 2003 IEEE
![Page 13: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/13.jpg)
Old OCT Does Not Register Images
As the eye moves, so does the scan location
Software algorithms reconstruct the data
Software assumes the lines are straight and intersecting
![Page 14: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/14.jpg)
Increasing Reports of OCT Artifact
Study % Artifact/Error
UCSD: Bartsch (2004) 42%
Duke: Ray (2005) 43%
USC: Sadda (2006) 92%
Bartsch et al. Optical Coherence Tomography: Interpretation Artifacts and New Algorithm. Proc. of SPIE. 2004 5370; 2140-2150.
Ray et al. Evaluation of image artifact produced by optical coherence tomography of retinal pathology. Am J Ophthalmol. 2005 Jan;139(1):18-29.
Sadda et al. Errors in retinal thickness measurements obtained by optical coherence tomography. Ophthalmology. 2006 Feb;113(2):285-93.
![Page 15: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/15.jpg)
Eye Tracking Stops 3D Motion Artifact
Artificial ripples due to eye movements
Without Eye Tracker
True anatomic structure
With Eye Tracker
![Page 16: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/16.jpg)
Spectralis Advantages
Eye Tracking – Every B-scan is simultaneously locked to a reference image
Up to 6 modes – Multiple perspectives of the anatomy from multiple wavelengths
40 kHz scanning – High speed helps overcome eye movement artifact and increases patient comfort
TruTrack™ – Image alignment compares reference location at baseline to follow-up
Heidelberg Noise Reduction Technology – Overcomes the limits of “resolution”
![Page 17: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/17.jpg)
AF – Occult CNV
![Page 18: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/18.jpg)
IR – Central Serous Chorioretinopathy
![Page 19: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/19.jpg)
ICGA – RAP
![Page 20: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/20.jpg)
ICGA – CNV with Choroidal Hemangioma
![Page 21: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/21.jpg)
AF – Occult CNV
![Page 22: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/22.jpg)
AF – Diabetic Retinopathy
![Page 23: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/23.jpg)
6 Billing Codes (example for United States)
92135 Scanning Diagnostic Imaging 92235 Fluorescein Angiography 92240 ICG Angiography 92250 Red Free Fundus Photography 92285 External Ocular Photography 92287 Internal Eye Photography (Iris
Angiography)
![Page 24: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/24.jpg)
Select From Three Versions
6 modes
SD-OCT
Infrared
Autofluorescence
Fluorescein Angiography
ICG Angiography
Red Free Photography
2 modes
SD-OCT
Infrared
-
-
-
-
5 modes
-
Infrared
Autofluorescence
Fluorescein Angiography
ICG Angiography
Red Free Photography
HEYEX Database
![Page 25: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/25.jpg)
HEYEX Network Solution
IR FA IR OCT
HEYEX
Registration Link
![Page 26: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/26.jpg)
Heidelberg Engineering Imaging Suite
IR IR OCT
HEYEX
FA Fundus
Registation Link
OCT
![Page 27: The Fusion of Imaging Technologies INTRODUCING. Spectralis is more than resolution … Time Domain OCT SPECTRALIS](https://reader035.vdocuments.us/reader035/viewer/2022062320/56649cca5503460f94993560/html5/thumbnails/27.jpg)
Red Free Autofluorescence
Infrared
ICG Angiography
Fluorescein Angiography
The Fusion of Imaging TechnologiesThe Fusion of Imaging Technologies