the fluid does not come into contact with the moving parts

2
Panel mounting Direct mounting Pinch Valve 2 patterns of mounting Electrical faults due to scattering of liquid prevented by panels between the flow and coil sides Less damage to the tube due to an arc shape of the tube clamp Can be mounted from the front Valve closed Valve width Insertion through the hole is necessary. U shaped tube slot O shaped tube slot Improved tubing life *1 Built-in power saving circuit Easy tubing replacement New New Existing model Circular arc shape 20 mm Compact Valve width On/Off Flow control through direct pinching of tubing Coil side Panel Mounting screw Fluid side Mounting screw O shape U shape The fluid does not come into contact with the moving parts of the valve, so there is no inflow of contaminants. By discarding a tube after use, the need for a washing process is eliminated, thus ensuring good hygiene. Power consumption : 1.5 W *1 INFORMATION LPV22-X1 19-E741

Upload: others

Post on 16-Oct-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The fluid does not come into contact with the moving parts

Panel mounting Direct mounting

Pinch Valve

2 patterns of mounting

Electrical faults due to scattering of liquid prevented by panels between the flow and coil sides

Less damage to the tube due to an arc shape of the tube clamp

Can be mounted from the front

Valve closed

Valve width

Insertion through the hole is necessary.

U shaped tube slot O shaped tube slot

Improved tubing life

*1 Built-in power saving circuit

Easy tubing replacementNewNew Existing model

Circular arc shape

20 mmCompactValve width

On/Off Flow control through direct

pinching of tubing

Coil side

Panel

Mountingscrew

Fluid side

Mounting screw

O shape

U shape

The fluid does not come into contact with the moving parts of the valve, so there is no inflow of contaminants. By discarding a tube after use, the need for a washing process is eliminated, thus ensuring good hygiene.

Power consumption : 1.5 W*1

INFORMATION

LPV22-X119-E741

Page 2: The fluid does not come into contact with the moving parts

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPANPhone: 03-5207-8249 Fax: 03-5298-5362https://www.smcworld.com© 2020 SMC Corporation All Rights Reserved

Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

D-G

Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.

Tube clamp

20

Lead

wire

leng

th

24

73

26.8

20.3

17

ø19.5

14

2 x ø2.7Mounting hole thread size:M2.5Proper tightening torque:0.25 to 0.35 N·m

2 x M3 x 0.5Thread length 4Proper tightening torquefor mounting: 0.4 to 0.6 N·m

Recommended panel holedimensions for valve mounting

17 ±0.1

14 ±

0.1

ø20

ø4.5

7.45

2.8

6.6

Pan

el th

ickn

ess:

3 m

m o

r le

ss

UL1007AWG22

19.5

2 x ø2.7

Specifications

Dimensions

Applicable tubing*1 Silicone O.D.: ø4 I.D.: ø2 O.D.: ø5/32" I.D.: ø1/32"

Type of actuation Direct operated solenoid

Valve type N.O.

Rated voltage 24/12 VDC

Allowable voltage fluctuation ±10% of the rated voltage

Power consumption Starting: 8 W Holding: 1.5 W [Built-in power saving circuit]

Ambient temperature 0 to 50°COperating pressure 0 to 0.2 MPa

Impact/Vibration resistance m/s2*2 150/30

Enclosure IP40 equivalent

*1 Silicone tubing should be provided by the customer.*2 Impact resistance: No malfunction occurred when it is tested in the axial direction and at the

right angles to the armature in both energized and de-energized states every once for each condition. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states for each condition. (Value in the initial state)

LPV22-X1