the fluid does not come into contact with the moving parts
TRANSCRIPT
![Page 1: The fluid does not come into contact with the moving parts](https://reader030.vdocuments.us/reader030/viewer/2022012410/616a548211a7b741a351519b/html5/thumbnails/1.jpg)
Panel mounting Direct mounting
Pinch Valve
2 patterns of mounting
Electrical faults due to scattering of liquid prevented by panels between the flow and coil sides
Less damage to the tube due to an arc shape of the tube clamp
Can be mounted from the front
Valve closed
Valve width
Insertion through the hole is necessary.
U shaped tube slot O shaped tube slot
Improved tubing life
*1 Built-in power saving circuit
Easy tubing replacementNewNew Existing model
Circular arc shape
20 mmCompactValve width
On/Off Flow control through direct
pinching of tubing
Coil side
Panel
Mountingscrew
Fluid side
Mounting screw
O shape
U shape
The fluid does not come into contact with the moving parts of the valve, so there is no inflow of contaminants. By discarding a tube after use, the need for a washing process is eliminated, thus ensuring good hygiene.
Power consumption : 1.5 W*1
INFORMATION
LPV22-X119-E741
![Page 2: The fluid does not come into contact with the moving parts](https://reader030.vdocuments.us/reader030/viewer/2022012410/616a548211a7b741a351519b/html5/thumbnails/2.jpg)
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPANPhone: 03-5207-8249 Fax: 03-5298-5362https://www.smcworld.com© 2020 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
D-G
Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.
Tube clamp
20
Lead
wire
leng
th
24
73
26.8
20.3
17
ø19.5
14
2 x ø2.7Mounting hole thread size:M2.5Proper tightening torque:0.25 to 0.35 N·m
2 x M3 x 0.5Thread length 4Proper tightening torquefor mounting: 0.4 to 0.6 N·m
Recommended panel holedimensions for valve mounting
17 ±0.1
14 ±
0.1
ø20
ø4.5
7.45
2.8
6.6
Pan
el th
ickn
ess:
3 m
m o
r le
ss
UL1007AWG22
19.5
2 x ø2.7
Specifications
Dimensions
Applicable tubing*1 Silicone O.D.: ø4 I.D.: ø2 O.D.: ø5/32" I.D.: ø1/32"
Type of actuation Direct operated solenoid
Valve type N.O.
Rated voltage 24/12 VDC
Allowable voltage fluctuation ±10% of the rated voltage
Power consumption Starting: 8 W Holding: 1.5 W [Built-in power saving circuit]
Ambient temperature 0 to 50°COperating pressure 0 to 0.2 MPa
Impact/Vibration resistance m/s2*2 150/30
Enclosure IP40 equivalent
*1 Silicone tubing should be provided by the customer.*2 Impact resistance: No malfunction occurred when it is tested in the axial direction and at the
right angles to the armature in both energized and de-energized states every once for each condition. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states for each condition. (Value in the initial state)
LPV22-X1