the ericsson commands

28
The ERICSSON commands listed below are for these functions RLCRP:CELL=ALL; ----------- for viewing all the cells of BSC sites ( BSC ) DTSTP:DIP=ALL; ------------- for viewing state of digital path and links ( MSC & BSC ) MGSVP: ------------------------ for checking subscribe base ( MSC ) STRSP:R=ALL; ----------------- for checking all route ( MSC & BSC ) dtbli:dip=rblt**; --------- ----blocking of dip dtble:dip=rblt**; --------- ------deblocking of dip rxmsp:mo=rxotg-**,subord; ------- management object status rxmfp:mo=rxotg-**,subord; ---------- fault print comand for management object Ericsson Tips Here are three sections of Ericsson MML and printout explanations that may be useful. These are commands which are used on a daily basis, however, explained in greater detail then the face value they are typically taken for. If you have any questions feel free to email me, [email protected] Understanding the DIP Quality stats dtqup:dip=53rblt;

Upload: vineet-singh

Post on 22-Nov-2014

1.563 views

Category:

Business


65 download

DESCRIPTION

 

TRANSCRIPT

Page 1: The ericsson commands

The ERICSSON commands listed below are for these functions

RLCRP:CELL=ALL; ----------- for viewing all the cells of BSC sites ( BSC )

DTSTP:DIP=ALL; ------------- for viewing state of digital path and links ( MSC & BSC )

MGSVP: ------------------------ for checking subscribe base ( MSC )

STRSP:R=ALL; ----------------- for checking all route ( MSC & BSC )

dtbli:dip=rblt**; --------- ----blocking of dip

dtble:dip=rblt**; --------- ------deblocking of dip

rxmsp:mo=rxotg-**,subord; ------- management object status

rxmfp:mo=rxotg-**,subord; ---------- fault print comand for management object

Ericsson Tips

Here are three sections of Ericsson MML and printout explanations that may be useful. These are

commands which are used on a daily basis, however, explained in greater detail then the face

value they are typically taken for.

If you have any questions feel free to email me, [email protected]

Understanding the DIP Quality stats

dtqup:dip=53rblt;

Page 2: The ericsson commands

DIGITAL PATH QUALITY

INCOMING AND OUTGOING DIRECTION

DIP T1 T2 SLIP SLIP2 UAS UASR UAV1 UASB1 UAV2 UASB2

53RBLT 13 7 0 0 0 0 0

SECTION ESV SESV DMV ESVR SESVR DMVR SFV SFTI

0 0 0 0 0 0

SECTION ES2V SES2V DM2V ES2VR SES2VR DM2VR SMI

6 2 0 17 17 0

T1 is the number of minutes stats were recorded.

T2 is the number of hours.

In the above example, in the last 13 minutes the DIP took 0 hits.

In the last 7 hours there were 6 errored seconds (ES2V), 2 severely errored seconds (SES2V)

INCOMING, and 17 errored seconds (ES2VR), 17 severely errored seconds OUTGOING.

ESV Errored Seconds Incoming

ESVR Errored Seconds Outgoing

SESV Severely Errored Second Incoming

SESVR Severely Errored Seconds Outgoing

You can reset these stats, which is usually good to do after a telco repair, by using

Page 3: The ericsson commands

dtqsr:dip=53rblt,degr;

dtqsr:dip=53rblt,es,ses,sf;

dtqsr:dip=53rblt,es2,ses2,sf2;

Page 4: The ericsson commands

Determining what T1 a specific radio is using

Rxmdp:mo=rxotrx-293-0;

RADIO X-CEIVER ADMINISTRATION

MANAGED OBJECT DEVICE INFORMATION

MO DEVS DEVT SDEV

RXOTRX-293-0 RHDEV-837 RBLT24-2249 1111

The DEVT is the transmission device. Take the device number and divide this by

24. In this case 2249/24 = 93.70833, therefore the DIP would be 93RBLT.

If the transmission device is an RBLT24 the dip will be an RBLT. If the DEVT is an RBLT3 device, the DIP will be an RB3. (Example: DEVT RBLT3-300 = 12RB3, RBLT24-300 = 12RBLT)

Page 5: The ericsson commands

Checking traffic on a specific radio

You should be familiar with checking if a sector is taking traffic: rlcrp:cell=

To check if a specific radio is taking traffic you would combine this command with

the rxcdp:mo=

[BH2BSC4, BH0580, TG-22]

Rxcdp:mo=rxotg-22;

rxcdp:mo=rxotg-22;

RADIO X-CEIVER ADMINISTRATION

MANAGED OBJECT CONFIGURATION DATA

MO RESULT ARFCN MISMATCH

RXORX-22-0 CONFIG HOP NONE

RXORX-22-1 CONFIG HOP NONE

RXORX-22-2 CONFIG HOP NONE

RXORX-22-4 CONFIG HOP NONE

RXORX-22-5 CONFIG HOP NONE

MO RESULT ARFCN TXAD TN BPC CHCOMB OFFS XRA ICM

RXOTS-22-0-0 CONFIG 638 1 0 6106 BCCH 0 NO ON

RXOTS-22-0-1 CONFIG 638 1 1 6078 SDCCH8 0 NO ON

RXOTS-22-0-2 CONFIG 638 1 7 5993 TCH 0 NO ON

RXOTS-22-0-3 CONFIG 638 1 6 5988 TCH 0 NO ON

RXOTS-22-0-4 CONFIG 638 1 5 5985 TCH 0 NO ON

RXOTS-22-0-5 CONFIG 638 1 4 5980 TCH 0 NO ON

RXOTS-22-0-6 CONFIG 638 1 3 5977 TCH 0 NO ON

Page 6: The ericsson commands

RXOTS-22-0-7 CONFIG HOP 4 2 5095 TCH 0 NO ON

RXOTS-22-1-0 CONFIG HOP 4 7 5943 TCH 0 NO ON

RXOTS-22-1-1 CONFIG HOP 4 6 5940 TCH 0 NO ON

RXOTS-22-1-2 CONFIG HOP 4 5 5937 TCH 0 NO ON

RXOTS-22-1-3 CONFIG HOP 4 4 5934 TCH 0 NO ON

RXOTS-22-1-4 CONFIG HOP 4 3 5931 TCH 0 NO ON

RXOTS-22-1-5 CONFIG 638 1 2 5135 TCH 0 NO ON

RXOTS-22-1-6 CONFIG HOP 4 1 5925 TCH 0 NO ON

RXOTS-22-1-7 CONFIG HOP 4 0 5922 TCH 0 NO ON

RXOTS-22-2-0 CONFIG 630 2 0 6096 SDCCH4 3 NO ON

RXOTS-22-2-1 CONFIG 630 2 7 6031 TCH 3 NO ON

RXOTS-22-2-2 CONFIG 630 2 6 6025 TCH 3 NO ON

RXOTS-22-2-3 CONFIG 630 2 5 6019 TCH 3 NO ON

RXOTS-22-2-4 CONFIG 630 2 4 6015 TCH 3 NO ON

RXOTS-22-2-5 CONFIG 630 2 3 6009 TCH 3 NO ON

RXOTS-22-2-6 CONFIG 630 2 2 6004 TCH 3 NO ON

RXOTS-22-2-7 CONFIG 630 2 1 2064 TCH 3 NO ON

rlcrp:cell=bh0580a;

CELL RESOURCES

CELL BCCH CBCH SDCCH NOOFTCH QUEUED

BH0580A 1 0 8 14- 28 0

CHGR BPC CHANNEL CHRATE SPV STATE ICMBAND CHBAND 64K

0 5135 TCH-3871 FR 1,2,3 IDLE 1 1900 NONE

TCH-3870 HR 1,3 IDLE 1 1900

TCH-3845 HR 1,3 IDLE 1 1900

5993 TCH-33030 FR 1,2,3 IDLE 1 1900 NONE

Page 7: The ericsson commands

TCH-33029 HR 1,3 IDLE 1 1900

TCH-33028 HR 1,3 IDLE 1 1900

5988 TCH-33150 FR 1,2,3 IDLE 1 1900 NONE

TCH-33149 HR 1,3 IDLE 1 1900

TCH-33148 HR 1,3 IDLE 1 1900

5985 TCH-33273 FR 1,2,3 IDLE 1 1900 NONE

TCH-33272 HR 1,3 IDLE 1 1900

TCH-33271 HR 1,3 IDLE 1 1900

5980 TCH-33513 FR 1,2,3 IDLE 1 1900 NONE

TCH-33512 HR 1,3 IDLE 1 1900

TCH-33511 HR 1,3 IDLE 1 1900

5977 TCH-33759 FR 1,2,3 IDLE 1 1900 NONE

TCH-33758 HR 1,3 IDLE 1 1900

TCH-33757 HR 1,3 IDLE 1 1900

6078 SDCCH-37286 IDLE 1 1900

SDCCH-37285 IDLE 1 1900

SDCCH-37284 IDLE 1 1900

SDCCH-37283 IDLE 1 1900

SDCCH-37282 IDLE 1 1900

SDCCH-37281 IDLE 1 1900

SDCCH-37280 IDLE 1 1900

SDCCH-37279 IDLE 1 1900

6106 BCCH-37315 BUSY 1900

CHGR BPC CHANNEL CHRATESPV STATE ICMBAND CHBAND 64K

1 5095 TCH-31142 FR 1,2,3 IDLE 1 1900 NONE

TCH-31141 HR 1,3 IDLE 1 1900

TCH-31140 HR 1,3 IDLE 1 1900

5922 TCH-35219 FR 1,2,3 LOCK 1 1900 NONE

Page 8: The ericsson commands

TCH-35218 HR 1,3 BUSY 1 1900

TCH-35217 HR 1,3 BUSY 1 1900

5943 TCH-34349 FR 1,2,3 BUSY 1 1900 NONE

TCH-34348 HR 1,3 LOCK 1 1900

TCH-34347 HR 1,3 LOCK 1 1900

5940 TCH-34466 FR 1,2,3 BUSY 1 1900 NONE

TCH-34465 HR 1,3 LOCK 1 1900

TCH-34464 HR 1,3 LOCK 1 1900

5937 TCH-34565 FR 1,2,3 BUSY 1 1900 NONE

TCH-34564 HR 1,3 LOCK 1 1900

TCH-34563 HR 1,3 LOCK 1 1900

5934 TCH-34679 FR 1,2,3 BUSY 1 1900 NONE

TCH-34678 HR 1,3 LOCK 1 1900

TCH-34677 HR 1,3 LOCK 1 1900

5931 TCH-34784 FR 1,2,3 IDLE 1 1900 NONE

TCH-34783 HR 1,3 IDLE 1 1900

TCH-34782 HR 1,3 IDLE 1 1900

5925 TCH-35066 FR 1,2,3 IDLE 1 1900 NONE

TCH-35065 HR 1,3 IDLE 1 1900

TCH-35064 HR 1,3 IDLE 1 1900

END

Now to determine if a specific radio is taking traffic, match the Base Physical

Channel (BPC) from the RXCDP to the RLCRP printout. If the state of the

corresponding traffic channel is LOCK or BUSY then there is a call, whether data

or voice, on that channel or timeslot.

Page 9: The ericsson commands

Example:

TRU 1: BPCs

RXOTS-22-1-0 CONFIG HOP 4 7 5943 TCH 0 NO ON

RXOTS-22-1-1 CONFIG HOP 4 6 5940 TCH 0 NO ON

RXOTS-22-1-2 CONFIG HOP 4 5 5937 TCH 0 NO ON

RXOTS-22-1-3 CONFIG HOP 4 4 5934 TCH 0 NO ON

RXOTS-22-1-4 CONFIG HOP 4 3 5931 TCH 0 NO ON

RXOTS-22-1-5 CONFIG 638 1 2 5135 TCH 0 NO ON

RXOTS-22-1-6 CONFIG HOP 4 1 5925 TCH 0 NO ON

RXOTS-22-1-7 CONFIG HOP 4 0 5922 TCH 0 NO ON

From the above printout lets look at Timeslot 0/BPC 5943:

In the printout of resources from rlcrp:cell=bh0580a;

5943 TCH-34349 FR 1,2,3 BUSY 1 1900 NONE

TCH-34348 HR 1,3 LOCK 1 1900

TCH-34347 HR 1,3 LOCK 1 1900

This tells us there is traffic on TS 22-1-0, so TRU 22-1 is taking traffic.

allip:acl=a1; ! Alarm list print : Alarm class critical !< xml="true" prefix="o" namespace="">allip:acl=a2;allip:acl=o1;allip:alcat=apz;

Page 10: The ericsson commands

rxcdp:mo=rxotg-0;rxble:mo=rxocf-0,subord!,force;rxmfp:mo=rxocf-0,subord,faulty;rxmsp:mo=rxotg-0,subord;rxtcp:moty=rxotg,cell=was253b;rxmop:mo=rxotg-0; ! Find SW & Sitename !rxmop:mo=rxocf-0; ! Displays the TEI value !rxmop:mo=rxotrx-0-0!;rlcrp:cell=wac168b;rxapp:mo=rxotg-0; ! Print devices, divide any by 24 to get the DIP !rxasp:mo=rxotg-0; ! Prints the site name !

// Activate & Halt Sectorsrlstp:cell=wdc081c;rlstc:cell=wan156a,state=halted;rlstc:cell=wan156a,state=active;

// Check if site is LIVERlsbp:cell=abc001a; ! If CB=YES site is NOT live (Cell Barred) !

// AP File Processing Faultaploc;hostnamecdhdslsafpls -ls NYMSC019 OSSMETRICA | findstr FAILEDafpfti -f NYMSC019 OSSMETRICAafpls -ls NYMSC019 OSSMETRICA | findstr FAILEDalistexit

// File Transfer Failures – IOGAllip:alcat=apz,acl=a1;Infti:dest=bgw01,file=ttfile00-xxxx,equip=ftam;--If the INFTI fails with a fault code 10 then do the following:Imlct:spg=0;Ilbli:port=1-1-1-1;! Block internet port, Wait 1 minute !Ilble:port=1-1-1-1;End;Infti:dest=bgw01,file=ttfile00-xxxx,equip=ftam;

Page 11: The ericsson commands

// RoutesStrsp:r=route; ! Prints route state !Strdp:r=route; ! Prints devices, may use param “, state=bloc” !Exdep:dev=downdevice; ! Prints the SNT !Ntcop:snt=snt; ! Prints the DIPs with Devices !-If LIBL Maint check for WO’s, also verify circuit is In Service in granite-Continuity CheckBlodi:dev=device; ! Blocks device !Blode:dev=device; ! Deblocks device !-Try toggling T1 line coding & framing structureStdep:dev=updna51-112&&-136;Blodi:dev=updna51-112&&-136;Dtbli:dip=25up5;Dtidc:dip=25up5,lc=0,frs=0; ! Sets LineCoding & Framing Structure to 0 !Dtble:dip=25up5;Dtbli:dip=25up5;Dtidc:dip=25up5,lc=1,frs=1; ! Sets LineCoding & Framing Structure to 1 !Dtble:dip=25up5;Dtstp:dip=25up5;Blode:dev=updna51-112&&-136;Stdep:dev=updna51-112&&-136;

seqar:r=route !reset route supervision

// DIPsDtstp:dip=dip; ! Print state of DIP !Dtqup:dip=dip; ! Print quality stats !Dtqsr:dip=dip,degr; ! Reset quality stats !Dtqsr:dip=dip,ses,es; ! Reset quality stats !Dtbli:dip=dip; ! Block DIP !Dtdip:dip=dip; ! Extract SNT !

// RF Loop Test FaultRxbli:mo=rxotrx-0-0; ! Block affected radio !Rxese:mo=rxotrx-0-0; ! Take out of service !Rxesi:mo=rxotrx-0-0 ! Bring into service !Rxlti:mo=rxots-0-0-0 ! Runs loop test, any FAIL fops needs to replace radio !Rxble:mo=rxotrx-0-0; ! Deblock radio, should be fine !

// Size Alteration Fault IOG (sybue; will stop autobackup)aploc; ! Command will fail if IOG !dbtsp:tab=saactions; ! Print database table !sybue; ! Passivate the backup !saali; ! Increase size limit !plldp; ! Check processor load !sybup:file; ! Force backup !;sytuc; ! Sets # of backup files !sybui:disc; ! Activates backup !dpwsp; ! Verifies CP states !

// Size Alteration Fault APG (sybue; will stop autobackup)aploc; ! c:\ Prompt !mml ! Start MML session from DOS dbtsp:tab=saactions; ! Print database table !sybue; ! Passivate the backup !saali; ! Increase size limit !plldp; ! Check processor load !saosp; ! Check operating system ! ! If CP seperates after saali run backup immediately.sybup:file; ! Force backup !;sytuc; ! Sets # of backup files !

Page 12: The ericsson commands

sybui; ! Activates backup !dpwsp; ! Verifies CP states !

// AP Proccess Reinitiated, RestartedAploc;Cluster Res! Verify all resources are ONLINE, otherwise contact Tier 2 !Alist! Pay attention to the Alarm Identifier !! Replace after acease command !Acease 6023:0Exit* IF alarm repeatedly comes back open a ticket w/Tier 2 and call out.

Page 13: The ericsson commands

// RP Faultsrepri:rp=74; ! Repair Procedure !remri:rp=74,pcb=RPG3; ! Manual Intervention !recri:rp=74; ! Repair Check !

// EM Faultsrepri:rp=xx,em=xx;remri:rp=xx,em=xx,pcb=embinterface;;recri:rp=xx,em=xx;dpwsp;

// CP Faults, CALL SWITCH/TIER 2repci: ! CP Repair !remci:mag=CPU,PCB=CPU-B; ! Manual Intervention !recci; ! Repair Check !dpwsp;

// Group Switch FaultsGsstp; ! Prints GS’s & States !Gsbli:tsm=tsm-b-30; ! Blocks GS !Gstei:tsm=tsm-b-30; ! Tests GS !Gsble:tsm=tsm-b-30; ! Deblocks GS !Gsstp:tsm=tsm-b-30; ! < xml="true" prefix="st1" namespace="">Prints State !

// Group Distributed FaultsGdstp;gdstp:unit=XM-A-1-2,detail;gdbli:unit=XM-A-1-2;gdtei:unit=XM-A-1-2;gdble:unit=XM-A-1-2;

// SDIPsTpcop:sdip=sdip !Print the VT1’s and DIPs associated;Dtdip:dip=dip !Print the SNT!;Ntcop:snt=snt !Print DIPs and T1s!;Stdep:dev=rblt3-4728&&-4772 !Print state of devices, often you will find them MBL, if not test T1!;

// Continuity Check Failuretccfp:dety=UPDNAM; !We are looking to print the DEVstdep:dev=UPDNAM-19365; !Print the state of the DEVblodi:dev=UPDNAM-19365; !Block the DEVblode:dev=UPDNAM-19365; !Deblock the DEVIf the alarm comes back a TT will need to be sent to the switch

// SNT TRA Channel FaultsRadrp:dev=RTTAH1D-514&&-543; ! Prints RP/EM for devices !Exemp:rp=261,em=7; ! Prints EM data !Dpecs:rp=261,cm=7; ! Sets/Resets EM Control !

// SNT FaultsNtcop:snt=snt;Ntbli:snt=snt; ! Blocks SNT !Nttei:snt=snt; ! Tests SNT !Ntble:snt=snt; ! Deblocks SNT !

// Network Synchronization Faultnsdap;nsbli:ext=ext-1;nstei:ext=ext-1;nsble:ext=ex-1;

// EDGErlbdc:cell=nj8041a,numreqegprsbpc=0,chgr=0; ! Deactivate EDGE !

Page 14: The ericsson commands

rlbdc:cell=nj8041a,numreqegprsbpc=4,chgr=0; !Activate EDGE !rlbdp:cell=nj8041a; ! Status EDGE !

// SNT MUX faultsRrtbi:dev=x; ! Blocks devices !Rrtbe:dev=x; ! Deblocks devices !

// DPECS RP FaultsDtdip:dip=24rblt;Ntcop:snt=ETRBLT4-6,dipinf;Stdep:dev=RBLT24-576;Radrp:dev=RBLT24-576;Exemp:rp=66,em=8;Dpecs:rp=292,cm=0;

// System TestTest system; ! Should populate in NETX !End test;

// Semi perm connection faultsExscp:name=rk05067-smlc; ! Prints data !

// Software ErrorsSyrip:survey;

// SNT Faultsntcop:snt=UPETNAM-18exdrp:dev=UPETNAM-18exrpp:rp=290; !RP's run in parallel - we need to switch it to the other processor. This will list the other processordpecs:rp=291,cm=4; !switch rp dpecs:rp=290,cm=4; !switch backIf alarm doesn't clear sent to switch

Find the event that lists YESCopy the Code, INF1, INF2 and remove all spacesChoose correct link BSC or MSChttp://10.16.2.251/ericsson/errors/msc/totals/http://10.16.2.251/ericsson/errors/bsc/totals/Open newest documentSearch (Control+F) for the code/inf1/inf2 stringIf not found, create ticket to Tier 2 Ericsson..Include entire line where event=yesRun below command and include from start of printout to end of Faulty Block

Syrip:event=x,noprint=all; ! Prints out faulty block, clears alarm !

/ \ | BLOCK=block / \|LASLP: + |,PXPRINT|+ ; | BN=bn \ /| \ /laslp:bn=h'025C;

If h'025C doesn't work invert the INF1 block to h'5C02

This will give you the block. Open Tier II's website and goto Ericsson -> East SR's -> GSM CSR LIST

Do a Ctrl + F on the block on the website. If it is found then Tier II & Ericsson are aware of the software problem and will release a patch in the future.

saaep:sae=451; Do the saactions and find the block. Use Alex to search what this block represents.

Page 15: The ericsson commands

// Backup CommandsSybup:file;Sytuc;Sybui:disc;

// SS7 Status/BouncingS7lsp:ls=211-172-204; ! Use if linkset unavailable !S7lai:ls=211-173-199,slc=8; ! Blocks SLC !S7lae:ls=211-173-199,slc=8; ! Deblocks SLC !S7dep:dest=211-173-0; ! Use if destination alarm !S7pcp:dest=all;S7dep:dest=211-173-199;S7slp:ls=211-196-209;S7glp:ls=211-196-209;S7opp; ! Print SS7 link & cilli !S7rsp:dest=all; ! Print all signalling routing data !

// Ports Block DeblockImlct:spg=0; ! Allows for IO commands !Ilbli:np=1-1-4-1; ! Blocks port !Ilble:np=1-1-4-1; ! Deblocks port !Ilnpp:np=1-1-4-1; ! Prints state !End; ! Exits from IO !

// Seizure Supervision of Devices (BSC)Rasap; ! Prints state of devices, if continually busy assign to switch !Rasar:dety=ralt3; ! Resets supervision alarm, ralt3/ralt24 !

// NSVCIRrgbp; ! Prints Sites on BSC data state !Rrvbi:nsvci=13562; ! Blocks down NSVCi !Rrnse:nsvci=13562; ! Takes the NSVCi OOS !Rrnsi:nsvci=13562; ! Restores NSCVi to service !Rrvbe:nsvci=13562; ! Deblocks NSVCi !Radrp:dev=RTGPHDV-64; ! Prints RP !Blrpi:rp=483; ! Block & Deblock RP if West Coast recommends !Rlgrp:cell=abc123a; ! Print # of active pdch on cell !Rlgsp:cell=abc123a; ! Print gprs data for cell !

// Cell Logical Chan Seiz Sprvsn SDCCH/TCHRlvlp; ! Prints supervision of cells, all should be Included !Rlvap; ! Prints any busy channel sites (Test T1) !Rlvar:chtype=sdcch; ! Resets supervision !

// Cell Seizuer Sprvsn of Log Chan Cell SitesRlvle:cell=wac168,chtype=sdcch; ! Ends supervision !Rlvli:cell=wac168,chtype=sdcch; ! Starts supervision !

// Rad Transcoder Pool Self Config TimeoutRrpar; ! Resets alarm, if continually comes in assign to Tier 2 !

// Rad Transcoder Pool Mean Hold TimeRrmsp:trapool=all;Rrmse:trapool=all; !or trapool=x!Rrmsi:trapool=all,acl=a2;

// Rad Transcoder Pool blockingRrtpp:trapool=all,printdev;Rrtpi:trapool=x; ! Blocks trapool !Rrtpe:trapool=x; ! Deblocks trapool !Rrtpp:trapool=x,printdev; ! Prints all devices belonging to transcoder pool !

Page 16: The ericsson commands

// User Exceeded Access Attempts (IOG)Iouae:user=username; ! Cancels user !Iouai:user=username; ! Reinstates user !! IF user requests password reset !Iougp; ! Prints user groups !Iouar:user=username; ! Removes account from element !Ioual:user=username,psw=password,usergr=usergroup; ! Add user back !

// Security alarms in APGaploc; ! Inits AP Local mode !alistnet user! Lists all users on system, email, call user to verify it was them logging in !acease xxxx:x! Ceases alarm !exit ! Exits local mode !

// Disturbance Supervision RoutesDudap:r=route; ! Prints supervision data !Dudar:r=route; ! Resets alarm !

// Ali Faults! These are the whiteboards the switch sees alarms on !Alalp; ! Prints ALI status !Albli:ali=x; ! Block ALI !Alble:ali=x; ! Deblock ALI !

// Seizure Supervision MSCSetip; ! Prints supervision data !Setar; ! Resets alarm !

// APG check node status! Logs in local mode, checks AP state, verifies node your in, checks all resources are ONLINE, and prints alarm list !Aploc;PrcstateHostnameCluster ResAlist

// Test SystemsTest System; ! Inits a test system alarm to NETX !End Test; ! Ends the test !! Below will clear a stuck Test System alarm in the element, however this really shouldn’t be run !Iocmi:IO2=NVT-779;End test;Iocme;Iocmi:io2=at-xx;End test;Iocme;

// Print all BSCs on MSCMgbsp:bsc=all;

// Find Neighboring CellsRlncp:cell=bas055a;

// Semi perm connected devicesExscp:dev=x;Exsce:dev=x;

// Set allip times

Page 17: The ericsson commands

alltc:time=1930&1932;alltp;calcp;

// Accounting Class Data Output AlarmAcolp; ! Data Print !Acoar; ! Alarm Reset !

// Power Boost on 2106Rxbli:mo=rxotrx-27-0,subord,force;Rxese:mo=rxotrx-27-0,subord;Rxmoc:mo=rxotx-27-0,mpwr=47;Rxmop:mo=rxotx-27-0;

// Metrica StatusImlct:spg=0;Sddop:objtype=cp,area=oper; ! Print status of metrica counters !Sddci; ! Inits stat counter !Sddti; ! Inits translation tables !Sddop:objtype=cp,area=oper; ! Verify metrica counters are active !End;Sdfop:rptid=all; ! List reports and attached files !Sdtpp:mp=all; ! Print measurement program info !Sdtpi:mp=0; ! End measurement program !Sdtpe:mp=0,date=yyyymmdd,time=hhmm,int-15; ! Start measurement program !

// Network SynchronizationNsdap; ! Print network sync supervision data !Nsbli:dip=1ralt; ! Block dip for network sync !Nstei:dip=1ralt; ! Test the network sync device !Nsble:dip=1ralt; ! Deblock the dip for network sync !

// Volume Table InfoInmct:spg=0;Invop; ! Lists volume tables !Invop:vol=callvolume; ! Check call volume !Ilrop:rot=all; ! DCS route data !

// ABIS Path UnavailableRxapp:mo=rxotg-10; ! Abis Path status !Rxapi:mo=rxotg-10,dcp=10,dev=rblt24-10; ! Adds dev to tg as dcp x !Exdai:dev=rblt24-1010; ! In service for added dev !Blode:dev=rblt24-1010; ! Deblock added dev !Stdep:dev=rblt24-1010; ! Dev status !Rxapp:mo=rxotg-10; ! Verify added dev are on abis path !! Then reload radio with fault !

// Forlopp PrintoutsSyfap:all; ! Prints all active forlopps !Syfup; ! Prints forlopp duration supervision !Syfip:fid=xxxx; ! Prints users connected to forlopp !Syfsp; ! Prints forlopp execution status !

// Forlopp ReleaseRxmop:mo=rxotg-10; ! Prints sw version and tg forlopp id !Syfip:fid=h’022c-0000; ! Prints user connected to forlopp !Syfri:fid=h’022c-0000,filenum=h’1,ind=h’27cb,block=rxcmoo; ! Init forlopp release on block/fid !

Page 18: The ericsson commands

// CPT FaultImlct:spg=0;Illbi:np=1-1-1-3-1; ! Block cpt link 1 !Illbi:np=1-1-1-3-2; ! Block cpt link 2 !Illbi:np=1-1-1-3-3; ! Block cpt link 3 !Illbi:np=1-1-1-3-4; ! Block cpt link 4 !Illbe:np=1-1-1-3-1; ! Block cpt link 1 !Illbe:np=1-1-1-3-2; ! Block cpt link 2 !Illbe:np=1-1-1-3-3; ! Block cpt link 3 !Illbe:np=1-1-1-3-4; ! Block cpt link 4 !End;

// Sytuc fault code 53Infit:file1=file_a,file2=file_b; ! Copy file a to file b, a is unchanged, can take 20min to clear !

// Continuity Check FailureTccfp:dety=upd53p; ! Print cont check fault data !Stdep:dev=upd53p-1000; ! Print device state details !Blodi:dev=upd53p-1000; ! Block device !Exdae:dev=upd53p-1000; ! Place device OOS !Exdai:dev=upd53p-1000; ! Place device in service !Tccci:dev=upd53p-1000; ! Perform cont check test !Strdp:r=jklvm1o; ! Print route device state !

// Signalling Fault SupervisionFaiap:r=all; ! Print signalling fault supervision devices !Faiar:r=routeo&routei; ! Reset fault supervision alarm !

// Transaction Logs ! Prints log of users running specific cmds at specific times !Mcstp:command=allip,user=mnatale,stime=0030,sdate=20060319,etime=0030,edate=20060320;

// SP Trace SystemImlct:spg=0;Imtsp;! Prints test system info !Imtsi:mode=nosig,node=all;! Activate test system !Imtse:node=all;! Deactivate test system !

// Miscellaneous Cell Admin CommandsRlbdc:cell=abc123a,numreqbpc=8; ! Reset bpcfail on timeslots !Rlstp:cell=all,state=active; ! Print all active cells !Rlstp:cell=all,state=halted; ! Print all halted cells !Rldep:cell=abc123a; ! Print cell description data !Rlnrp:cell=abc123a,cellr=all; ! List external neighbor cells !Rlncp:cell=abc123a; ! To internal neighbor cells !Rlcpp:cell=abc123a; ! Cell power data print !Rlcfp:cell=abc123a; ! Radio Frequencies !Rldgp:cell=all; ! Prints cell chgr data !Rllap:lai=310-27-40540; ! Prints cells in LAI !Mgsar:log=unknown; ! Reset logs !Mgsgp:log=grey,nlog=all; ! Print imei log !Mgaar; ! Reset authentication !Mgarp:nlog=all; ! Print failed authentication log !Cofar; ! reset file congestion !Rrmar:trapool=all; ! Reset trapool !Rxpli:mo=rxocf-10,uc; ! Load software to CF !Rlsli:cell=abc123a,sctype=(ul/ol); ! Logical chan supervision init !

Page 19: The ericsson commands

// MISCELLANEOUS Exrpp:rp=all; ! RP Data Print !Plldp; ! Check Processor Data Load !Mgcep:cell=all; ! Print all cells connected to MSC respective BSC !Rablp:dety=all; ! Check supervision on for devices !Rrmsp:trapool=all; ! Check transcoder supervision !Sybtp; ! Check backup time !Saosp; ! Print O/S info !Rxelp:mo=rxotg-13; ! Error Log !Apamp; ! Prints AP Maintenance Tables !Rxhdp:mo=rxots-13-0-0&&-7; ! Maps MAIO to TS !Rlbdp:cell=wan010a; ! Defined Logical Channels !Rlslp:cell=wan036a; ! Number of Logical Channels available !Rldep:cell=wan010a; ! Description Data !Rlcfp:cell=wan010a; ! Frequencies on site !Rlchp:cell=wan010a; ! Channel Groups and MAIOs !Rlnrp:cell=wan010a,cellr=wan010b; ! Neighbor relation parameters !Rlnrp:cell=wan010a,cellr=all; ! All Neighbor relations !Rlsbp:cell=wdc018c; ! Cell Barred !

Imlct:spg=0; ! To access counters in non-APG 40 BSCs !Sdtdp:rptid=101,objtype=celtchf,obj=wan010a,int=15;! Drops and Traffic for 15 minutes !Sdtdp:rptid=165,objtype=cltchdrf,obj=wan010a,int=15;! Detailed Drops for last 30 minutes !Sdtdp:rptid=151,objtype=ncellrel,obj=wan010a-wan010b,int=1;! Handover stats within BSC for last hour !Sdtdp:rptid=150,objtype=necellrel,obj=wan010b-wdc039a,int=2;! Handover stats to site outside BSC for last 2 hours !

Sdtdp:rptid=210,int=15;! Drops per Timeslot report for all day yesterday !Sdtdp:rptid=234,objtype=celtchh,obj=wdc018c,int=24;! HR Drops for all day yesterday !Sdtdp:rptid=241,objtype=cltchdrah,obj=wdc018c,int=24,per=cur;! Detailed HR Drops for all day today !End; ! To get out of counters !

! To access counters in APG 40 BSCs !Aploc;! Drops and Traffic from midnight to 9 am !Stmfo -i -z LF -b 200408010000 -s 200408010900 -d drops_til_9am_aug01 CELTCHF! Detailed Drops !Stmfo -i -z LF -b 200408010000 -s 200408010900 -d detaileddrops_9am_aug01 CLTCHDRF

// Daily NSSdpwsp;caclp;allip;test system;end test;infdp;chodp:fn=tt;infsp:file=ttfile01,dest=bgw02,order=last;strsp:r=all;blorp;s7lsp:ls=all;s7ncp:sp=all,ssn=all;mgcop:giwu=all,giwsu=all;c7ltp:ls=all;strdp:r=miwud;

// Call Routing & Tracing

Page 20: The ericsson commands

! Tracing a call from an Ericsson MSC, run from an MSC !Extpe:bnb=19736443927; ! Clears your test # from switch !Extpi:bnb=19736443927; ! Initiates the test # !Tctdi:bnb=dialed,anb=dialedfrom ! Test phone will ring, answer it !Con; ! Connects the two !End; ! Ends the call !

TCTDI:BNB=(DIALED DIGITS),BO=30; replicates a mobile originated call, without an “A” number presentation

TCTDI:BNB=(DIALED DIGITS),BO=10; replicates an incoming from PSTN call through tree 10.(replicates a call from Outside our network after it hits our switch)

So….. you’ve replicated the error by making a test call.. and now you want to see how its routing from the switch

All mobile originated calls route from tree 30. 30 is the starting origin…

So you will start like this:

Anbsp:b=30-1(NPANXX);

Example:

<anbsp:b=30-1610863;

NE: NYMSC08 ID: 3956060 TIME: 01/31/2006 09:24:01

B-NUMBER ANALYSIS DATA

OPERATING AREA

B-NUMBER MISCELL F/N ROUTE CHARGE L A

30-1 CC=1 L=1-11

30-16 L=4-11

30-161

30-1610 F=90

The above shows you how its going out of tree 30 and is telling you that you will take the Full digits to tree 90 (F=90) so your next command will be:

Anbsp:b=90-1610863;

<anbsp:b=90-1610863;

NE: NYMSC08 ID: 3956060 TIME: 01/31/2006 09:26:40

B-NUMBER ANALYSIS DATA

OPERATING AREA

Page 21: The ericsson commands

B-NUMBER MISCELL F/N ROUTE CHARGE L A

90-1 N=190 L=11

BNT=4

END

The above is showing you how the switch is going to break out the code..it is saying from tree 90 you will take the next past the “1” to tree 190. So your next command will be like this:

Anbsp:b=190-610863; <notice NO 1

<anbsp:b=190-610863;

NE: NYMSC08 ID: 3956060 TIME: 01/31/2006 09:29:31

B-NUMBER ANALYSIS DATA

OPERATING AREA

B-NUMBER MISCELL F/N ROUTE CHARGE L A

190-6

190-61

190-610 F=189 RC=86

D=3-1

TRD=610

END

The above is showing you again how it is breaking out the code further. Even though you see a routing case here, that’s not necessarily where it stops in the rougting.. but the code might default back here…

So you will follow the map that its outlining further.. it is telling you above to take the FULL to tree 189 (F=189)…so your adding the one back….(FYI..tree 189 is where we would break out mobile codes…if Tmobile had a block of code in this npa-nxx)

Anbsp:b=189-1610863;

<anbsp:b=189-1610863;

NE: NYMSC08 ID: 3956060 TIME: 01/31/2006 09:33:25

B-NUMBER ANALYSIS DATA

OPERATING AREA

B-NUMBER MISCELL F/N ROUTE CHARGE L A

Page 22: The ericsson commands

189-1 N=189

END

The above is telling you to take the NEXT to tree 189 (N=189)so you will run the following:

Anbsp:b=189-610863;

<anbsp:b=189-610863;

NE: NYMSC08 ID: 3956060 TIME: 01/31/2006 09:34:23

B-NUMBER ANALYSIS DATA

OPERATING AREA

B-NUMBER MISCELL F/N ROUTE CHARGE L A

189-6

189-61

189-610

189-6108

189-61086

189-610863 F=200

END

This is again telling you to take the FULL to tree 200…so you will run this:

Anbsp:b=200-1610863; < notice the 1 back in there

<anbsp:b=200-1610863;

NE: NYMSC08 ID: 3956060 TIME: 01/31/2006 09:36:02

B-NUMBER ANALYSIS DATA

OPERATING AREA

B-NUMBER MISCELL F/N ROUTE CHARGE L A

200-1 N=200 L=11

END

The next past the 1 again to tree 200:

Page 23: The ericsson commands

Anbsp:b=200-610863;

<anbsp:b=200-610863;

NE: NYMSC08 ID: 3956060 TIME: 01/31/2006 09:37:01

B-NUMBER ANALYSIS DATA

OPERATING AREA

B-NUMBER MISCELL F/N ROUTE CHARGE L A

200-6

200-61

200-610

200-6108

200-61086

200-610863 RC=481

END

OH WOW>.. look your at the end.. you have the ending routing case!! YAY.. it didn’t default back to RC 86…so now lets see what we do with RC=481

ANRSP:RC=481;<ANRSP:RC=481; NE: NYMSC08 ID: 3956060 TIME: 01/31/2006 09:39:02

ROUTING CASE DATAOPERATING AREARC CCH BR ROUTING SP DATA481 YES P01=1 R=IMG008O BB1 COT EST SI ESS ESR 0 0 0 0

BNT RN SPR OLI OLI2

00 0

ISC FCP D

0

P01=2 R=IMG108O BB1 COT EST SI ESS ESR

0 0 0 0

BNT RN SPR OLI OLI2

00 0

Page 24: The ericsson commands

ISC FCP D

0

P01=3 NRC=498

END

<The frist thing you look at one your looking at the routing case is the PO1 (or the first position of the routing). In the case above.. all calls from NYMSC 8 to pennsylania code 610863, takes an IMT to Gateway 00 (IMG008o). <kinda translated like inter-machine Gateway 00 from msc 8 originate)

SO…YOUR NOT DONE!

Your call was failing from MSC 8..but it looks like MSC 8 is doing its job and sending the call appropriately to gateway 00…..hmm… maybe the problem is there…so.. guess what your going to do now???

You got it….!! You now will go into Ericsson GMSC 00 and do the same thing as above !!!!

Until you find the error.. or you find the outside (maybe) source that is not properly routing the call out of our switches.

// Radio Transmission Transcoder and Rate Adaptor Fault

rrtbi:dev=RTTGD-25,force; !If there is a call on this device it will drop it !

rrtbe:dev=RTTGD-25; ! Unblock the transcoder device !

Dealing with cell supervision alarms< xml="true" prefix="o" namespace="" ns="urn:schemas-microsoft-com:office:office">

A2/APT "NEBSC001HB00001" 340 070206 1849 CELL LOGICAL CHANNEL AVAILABILITY SUPERVISIONCELL SCTYPE CHTYPE CHRATE SPVBS608B TCH FR 1

First, we can check the whole sector for supervision data. The above A2 alarm printout tells us the fault is on a full rate TCH (traffic channel) with an SPV value of 1.

<rlslp:cell=bs608b;CELL SUPERVISION OF LOGICAL CHANNEL AVAILABILITY DATA

CELL SCTYPEBS608B

ACTIVE CHTYPE CHRATE SPV LVA ACL NCHYES BCCH 1 A1 1 SDCCH 8 A2 8 TCH FR 1 12 A2 6 TCH FR 2 0 A3 6 TCH FR 3 0 A3 6 TCH HR 1 0 A3 12 TCH HR 3 0 A3 12

Page 25: The ericsson commands

CBCH 0 A2 0END

Anytime the LVA or (Limit Value for Availability) is greater than the NCH (Number of Available channels) this alarm will be generated. Otherwise we can reset the supervision.

Rlsle:cell=bs608b;

This will turn off supervision on a sector. No new alarms will be generated.

Rlsli:cell=bs608b;

Supervision will be turned back on. Again, this is only a temporary fix if the LVA value is set too high. The switch will be able to change the LVA to prevent it from alarming in the future.

B-Number Analysis is used trace the journey though the switches and BSC's. I traced mine out of boredom today and come up with some interesting results.

First, B-Number analysis uses your NPA-NXX to find the routing sequence. My phone number is 484-832-1502. I then use just 484-832 in my analysis.

<anbsp:b=30-1484832;B-NUMBER ANALYSIS DATAOPERATING AREAB-NUMBER MISCELL F/N ROUTE CHARGE L A30-1 CC=1 L=1-1130-14 L=4-11

30-148 F=90END

The default tree in our network always starts with trunk 30. The anbsp command is analysis b spec print. The number we are mainly looking at is the route. Next, we basically run the same command but replace the tree with 90.

<anbsp:b=90-1484832;B-NUMBER ANALYSIS DATAOPERATING AREAB-NUMBER MISCELL F/N ROUTE CHARGE L A

90-1 N=190 BNT=4

END

So, we did two routing analysis and we are making progress. Let's keep going.

<anbsp:b=190-484832;B-NUMBER ANALYSIS DATAOPERATING AREAB-NUMBER MISCELL F/N ROUTE CHARGE L A190-4190-48

190-484 F=189 RC=1421 D=3-1 TRD=484

END

Keep moving...

Page 26: The ericsson commands

<anbsp:b=189-484832;B-NUMBER ANALYSIS DATAOPERATING AREAB-NUMBER MISCELL F/N ROUTE CHARGE L A189-4189-48 189-484 189-4848

189-48483 F=200END <anbsp:b=200-484832;B-NUMBER ANALYSIS DATAOPERATING AREAB-NUMBER MISCELL F/N ROUTE CHARGE L A200-4200-48 200-484 200-4848 200-48483

200-484832 RC=480END

Now, as you can see above we have finished our B number analysis and now we have a routing case.

My first route is actually LNPQRY. This sounds about right because I ported my number into T-Mobile. LNPQRY is a Local Number Portability Query. After that the trunks are listed in order.But we are not done. The last IMT route goes to NYGMSC00 though our use of granite. After we populate the BSC / MSC in remedy, we can query by trunk group. We just need to drop the I or O from the trunking name. But, even after all this we are not finished. We have to do the same steps on GMSC0.

<anrsp:rc=480;ROUTING CASE DATAOPERATING AREARC CCH BR ROUTING SP DATA480 YES TN -0 P01=1 R=LNPQRY BB2 COT EST SI ESS ESR 0 0 1 0 BNT RN SPR OLI OLI2 4 00 0 ISC FCP D 0 P01=2 R=90TG0UO BB2 COT EST SI ESS ESR 0 0 0 0 BNT RN SPR OLI OLI2 00 0 ISC FCP D 0 P01=3 R=IMG1G0O BB1 COT EST SI ESS ESR 0 0 0 0 BNT RN SPR OLI OLI2 00 0 ISC FCP D 0 P01=4 R=IMG2G0O BB1 COT EST SI ESS ESR 0 0 0 0 BNT RN SPR OLI OLI2 00 0 ISC FCP D 0 P01=5 R=IM22G0O BB1 COT EST SI ESS ESR 0 0 0 0 BNT RN SPR OLI OLI2 00 0 ISC FCP D 0 P01=6 NRC=498 TN -1 P02=1 R=90TG0UO BB2 COT EST SI ESS ESR

Page 27: The ericsson commands

0 0 0 0 BNT RN SPR OLI OLI2 00 0 ISC FCP D 0 P02=2 R=IMG1G0O BB1 COT EST SI ESS ESR 0 0 0 0 BNT RN SPR OLI OLI2 00 0 ISC FCP D 0 P02=3 R=IMG2G0O BB1 COT EST SI ESS ESR 0 0 0 0 BNT RN SPR OLI OLI2 00 0 ISC FCP D 0 P02=4 R=IM22G0O BB1 COT EST SI ESS ESR 0 0 0 0 BNT RN SPR OLI OLI2 00 0 ISC FCP D 0 P02=5 NRC=498

END

MO StatusBLL Blocked due to loadingBLT Blocked due to testingMBL Manually blockedBLO Automatically blockedBLA Blocked due to Activity Needed