the dip meter log by majid marooq uajk
TRANSCRIPT
![Page 1: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/1.jpg)
WELL LOGGING
Majid FarooqRoll NO.14Semester 8th
![Page 2: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/2.jpg)
TOPIC:-
The Dipmeter Log
![Page 3: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/3.jpg)
OVERVIEW Introduction Principle &Processing Tools information Uses Interpretation Conclusion References
![Page 4: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/4.jpg)
INTRODUCTION It gives a continuous record of
formation dip or azimuth. It comes from two stage processes….. Modern tool become very sophisticated
because it consist of logging sonde &also positioning sonde.
Interpretation of this log in past require long processing while in recent days processing become easy even in laptop.
![Page 5: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/5.jpg)
PRINCIPLE AND PROCESSING The dipmeter tool measures dip by
comparing the displacements of microresistivity curves from opposing side of borehole wall.
Typically 4 pads are used with a single electrode on each paid,SHDT of SLB has two on each pad.
To derive a dip direction & azimoth from raw,tool produced resistivity curves needs computer processing.
The requirement is to correlate the curves around the borehole as to identify the various displacements.
![Page 6: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/6.jpg)
PROCESSING:-
![Page 7: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/7.jpg)
TOOLS INFORMATION
![Page 8: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/8.jpg)
USES
![Page 9: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/9.jpg)
INTERPRETATION The correctly processed dipmeter log is not
immediately intelligible, it requires a great deal of interpretation.
Dipmeter results show no selectivity, everything is mechanically measured.
Sedimentary and structural interpretation will be processed separately.
Sedimentary interpretation requires a detailed & small scale processing .
Structural interpretation needs same raw data & on broader scale.
![Page 10: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/10.jpg)
INTERPRETATION
![Page 11: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/11.jpg)
STRUCTURAL SEDIMENTARY
![Page 12: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/12.jpg)
Figure 5.2 New micro-resistivity logs combine resistivity with dipmeter data to produce ‘virtual cores’ in three dimensions. Such detailed borehole imaging, with a vertical resolution of less than 8 mm, allows the observation of sedimentary structures in the absence of mechanical core.
![Page 13: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/13.jpg)
CONCLUSIONS Dipmeter is an expensive tool to run, is still
not being used to its full extent, interpretation is to blamed.
During processing each step envolves geologically biased choices,so it must be a geologist who uses the computer.
The great lack in dipmeter work is that there are so few outcrop analogues & models of orientation data.
Recently arrived image logs are considered to replace the dipmeter.
![Page 14: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/14.jpg)
REFERENCES Serra,O., Stowe,I. and Motet
1993.Fundamentals of well log Interpretation, P269-290.
Rider M., 2002. The Geological Interpretation of Well logs, second edition, P169-198.
![Page 15: The Dip Meter Log By Majid Marooq UAJK](https://reader035.vdocuments.us/reader035/viewer/2022081722/58898f681a28ab330e8b4e21/html5/thumbnails/15.jpg)
??
????
THANK YOU.