the control unit’s appearance - vizit · figure 7 control unit within the 20-apartment...
TRANSCRIPT
BUD K-20
BUD K-20VIZIT
-302
OPERATING INSTRUCTION
-302Control Unit the Control Unit hereinafter is part of multi-apartment doorphones and video doorphonesof Series 300, and provides duplex intercom and remote entrance door unlocking.
The Control Unit contains an integrated commutator for 20 subscribers (apartments).
1. Openings for screws2. Mains cord3. Mains switch4. Holder5. Terminals to connect to the doorstation and lock6. Terminals to connect to the intercom line
( )
for fixing the Control Unit on a DIN-rail
PARTS LIST
The Control Unit’s Appearance
BUD 302K-20-
Screw 4x40
x 4 x 4
Operating Instruction
x 1
FastenersFuse
x 1
T200mAL
х 1
1 1
2 3 4 5
6
Anchor 4 40х
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 1 212015- ) /
SAFETY INSTRUCTIONS
WARNING! V
DOORPHONE / VIDEO DOORPHONE COMPONENTS
VIZITVIZIT UKP
RVS-4M, RVE-4240-40
M 5
VIZIT
DOORPHONE / VIDEO DOORPHONE FEATURES
VIZIT-
1 20
2
BVD-342x BVD-343x
Notes.1. PROXIMITY, k and 13.56 MHz from
2.
3.BUD-302K-20
The Cg the ,
,
The mains plug shall remain readily operable.
,
The Control Unit is compatible with
Doorstations / video doorstations of Series 300Apartment handsetsVideo monitors of SeriesDistribution amplifiersElectromagnetic locks ,Electromechanical locks / strikes 12 VDC / 0.6Amax.Buttons for exit ,
are Parts lists and specifications for every product are given in itsoperating instruction.
Calls to subscribers by dialing their apartment number
Duplex intercom up to seconds
Entrance door unlockingby pressing the button on the apartment handset / monitor during intercom
indoorkeys hereinafter)
Programmable unlocked state duration ( to seconds)
by apartment list up to keys for each of apartments
Key erasing e.g., in case of lost keys
Individual access code memorizing
Programming new individual access codes by subscribers
Enabling / disabling calls to a particular apartment (individual access code remains activated)
Beeps to indicate operating modes of doorphone / video doorphone
Ring sound in the apartment handset / monitor and beeps in the doorstation when calling
Beep in the apartment handset / monitor, when its key or individual access code is used
Displaying information on operating modes on a 4-digit LED of ,
General and individual access codes and keys are memorized in the memory chip, which is set in the socket on theControl Unit’s PCB. The Control Unit supports memory chips from other control units of Series 300. Wheninserting a compatible memory chip into the chip socket, all stored keys and access codes are recognized and supported.
ontrol Unit contains dangerous for life high voltage - .Unplu the unit before replacing fuse and connecting wires.To avoid damage or electric shock do not make any
repair when the power is on.
No metallic objects shall penetrate into ventilation openings of the unit. The unit shall not be exposed to dripping orsplashing and no objects filled with liquids shall be placed on the unit.
:
-- ( )--- ,-- .
All listed devices available upon request.
( )
:-- by dialling a four - digit general access code- by dialling a three - digit individual access code- by pressing the button- by applying keys (
Key memorizing ( )
( )
.
This function can be enabled or disabled during programming.
230
VIZIT-M 400
VIZIT-ML VIZIT-ML400x VIZIT-ML300х
EXIT 300 EXIT 00
80
EXITRF
6 0
Only VIZIT-RF keys ( 125 Hz ) VIZIT are supported.
�
�
�
�
�
�
�
�
�
�
�
�
�
(2)
(2)
(1)
(2)
®
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 2 212015- ) /
INSTALLATION
VIZIT
G!
CONNECTIONS
EXAMPLES OF WIRINGDIAGRAMS.
Terminals names and destinations
The Control Unit shall be installed in heated premises with sufficient ventilation, and securely fixed to a wall or inside theMounting Box Terminals shall be oriented .
/ video doorphone
Doorphone / video doorphone cables are connected to the Control Unit’s terminals on its PCB To access the PCB, takeoff the Control Unit’s cover. Make connections following wiring diagrams given in the section
,. Such conditions provide proper ventilation of the unit.
The unit can be fixed by means of a DIN-rail or screws.
Installation of other doorphone components is performed following their operating instructions.
.
horizontally
WARNIN Do not mount the unit near heating equipment!
For qualified installation, wiring and servicing refer to technical and commercial partners of VIZIT TM.The list of companies is given on VIZIT.EU ( .http://vizit.eu/eurounion/)
1
2
3
( ) Control U( )( )
1 -2 -3 -
Bosses on the nit's baseDIN-rail, 35mm (W) x 1-2mm (D)Holder for fixing
Mounting on a DIN-rail
( ) ,( )( )( ) Control Unit
1 –2 –3 –4 –
Hole (x4) 6 mm (diameter) 40 mm (depth)(x4)
Screw (x4)Anchor
Mounting on a wall
1
2
3
4
BUD-302K-20БУД-302K-20
To video monitorsand apartmenthandsets
Terminal Destination Address
D0, D1Terminals to connect subscriber devices
E0...E9
+DLDoor lock control
To door lock andbuttonEXIT-DL
ОР OPEN To buttonEXIT
SP+Speaker
To doorstation
SP-
MIC Microphone
+Е Supply voltage for doorstation
RXDoorstation data
TX Control Unit data
GND GroundTo doorstation and
buttonEXIT
TM Key reader
DSD
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 3 212015- ) /
The Control Unit is connected to the mains by means of its mains cord.
properthe section ) with respect to the rest of
wires in cable Use a twisted pair to increase immunity to electromagnetic disturbance.
( )
, ( ) ., ( ) .
( ).
:
Use copper wires for connections with regard to the acceptable cross-section and length shown in the below table:
o ensure operation of the doorstation built-in key reader,total capacitance of the circuit (see Fig. 1 in
the shall not exceed 1500 pF.
Apartment handset’s terminal or monitor’s from every apartment is connected to the terminals eitheror in the Control Unit, depending on the apartment number’s .
If the decade is then UKP’s or monitor’s shall be connected toIf the decade is then UKP’s or monitor’s shall be connected to
Apartment handset’s terminal or monitor’s from every apartment is connected to one of the terminalsin the Control Unit, depending on the apartment number’s unit (0 to 9)
Examples of connection
TM
Connection of apartment handsets UKP / video monitors
decadeevenodd
EXAMPLES OF WIRING DIAGRAMS
"+" LN+D0 D1
"+" LN+ D0"+" LN+ D1
"-" LN-Е0…Е9
Notes.
s
s.
1. For Doorstations BVD-313R and BVD-313RCP only: t
2.
3.
DO NOT use electromagnetic locks with impedance less than 20 Ohm and not provided with a built-indegaussing module.DO NOT use electromechanical locks with impedance less than 10 Ohm
Circuit
Wire
Maximum length, m
0.3Diameter, mm
0.07Cross-section, mm2 0.2 0.5
0.5 0.8
Con Doorstationtrol Unit(1)
-
Control Unit - Apartmenthandset (UKP) or monitor
Control Unit(2)
-(
Electromagneticlock )VIZIT-ML240-40
Control Unit(3)
- Electromechanicallock / strike
75 200
10 30
10 20
-
-
30 50
50
300
Flat No >
“+” UKP
“ ”- UKP
38 39 40 ...41 48 49 50 ...51 56 57
D1 ... ...D1 D0 D0 D0 D1D0 D1 D1 D1
E8 E9 E0 ...E1 E8 E9 E0 ...E1 E6 E7
Even decade
Flat No >
“+” UKP
“ ”- UKP
01 02 03 ... 08 09 10 11 ... 18 19 20
D0 ... ...D0 D0 D0 D0 D0D1 D1 D1 D1
E1 E2 E3 ... E8 E9 E0 E1 ... E8 E9 E0
Or
Odd decade
(See Fig. 7)
in the section EXAMPLESOF WIRING DIAGRAMS
(See Fig. 8)
in the section EXAMPLESOF WIRING DIAGRAMS
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 4 212015- ) /
Figure Doorstation, and button
1 - -3М
BVD 13R(RCP) BUD-302K-20EXIT 300
with Control Unit ,Electromagnetic Lock VIZIT-ML240-40
Red
Green White
Black
Blue
Electromagneticlock VIZIT-ML240-40
ButtonМEXIT 300
DBVD-313
OORSTATIONR(RCP)
TM 2SP 3
MIC 5DSD 6
GND 1
+E 4
123
654
Colour
VG 7VO 8
87
to commutatordistribution amplifier
/
4 51 3 62
RX
SP
-
TX
CONTROL UNITBUD-302K-20
+D
L-D
LO
P
TM
SP
+
GN
D
MIC
+E
DS
D
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
to apartment handsetsor monitors
7
EXAMPLES OF WIRING DIAGRAMS
Figure 2 Doorstation with Control Unit ,Electromagnetic Lock , and button
-3BVD 14F(FCP) BUD-302K-20VIZIT-ML240-40 EXIT 500
-
Electromagneticlock VIZIT-ML240-40
Green
White
Red
Black
DL+ ML
OP GND
Button5EXIT 00
123
654
DoorstationBVD 14R(RCP)-3
SP+SP-
MICRX
GND
+E
VOVG
7TX
89
black
brown
green
red
white
grey
blue
yellow
purple
to commutatordistribution amplifier
/
123
654
DOORSTATION-3BVD 14F(FCP)
SP+SP-
MICRX
GND
+E
PRGVG
7TX
8
VO9
pink( orange)or
black
brown
green
red
white
grey
blue
yellow
purple
to commutatordistribution amplifier
/
4 51 3 62 79
RX
SP
-
TX
CONTROL UNITBUD-302K-20
+D
L-D
LO
P
TM
SP
+
GN
D
MIC
+E
DS
D
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
to apartment handsetsor monitors
8
Note. .Connect PRG wire to GND terminal of Control Unit when memorizing MASTER-key No1Remember to disconnect PRG wire after MASTER-key No1 has been memorized.
Figure 3 - Doorstation with Control Unit , and electromechanical lock / strike-3BVD 14R(RCP) BUD-302K-20
4 51 3 62 7
V 0.6 MAX.ELECTROMECHANICAL
LOCK STRIKE/ (12 , А )
1N4007
If an electromechanical lock / strike has no built-in damper diode, the diode shall be setadditionally between terminals of the lock /strike as shown in the diagram.
+DL
-DL
8
RX
SP
-
TX
CONTROL UNITBUD-302K-20
+D
L-D
LO
P
TM
SP
+
GN
D
MIC
+E
DS
D
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
to apartment handsetsor monitors
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 5 212015- ) /
123
654
98
DOORSTATIONBVD 43R(RCPL)-3
SP+ 2SP- 3
MIC 5RX 6
GND 1
+E 4
VG 8VO 9
7TX 7
to commutatordistribution amplifier
/
Figure 4 Doorstation, and button
- -343М
BVD R(RCPL) BUD-302K-20EXIT 300
with Control Unit ,Electromagnetic Lock VIZIT-ML240-40
Red
Green White
Black
Blue
Electromagneticlock VIZIT-ML240-40
ButtonМEXIT 300
Figure 6 - Doorstation with Control Unit , and electromechanical lock / strike-34BVD 2R BUD-302K-20
4 51 3 62 7
1N4007
If an electromechanical lock / strike has no built-in damper diode, the diode shall be setadditionally between terminals of the lock /strike as shown in the diagram.
+DL
-DL
RX
SP
-
TX
CONTROL UNITBUD-302K-20
4 5
+D
L-D
LO
P
TM
SP
+
GN
D
MIC
+E
DS
D
1 3 62 78
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
to apartment handsets
Figure 5 Doorstation with Control Unit ,Electromagnetic Lock , and button
-343BVD F(FCPL) BUD-302K-20VIZIT-ML240-40 EXIT 500
-
Electromagneticlock VIZIT-ML240-40
Green
White
Red
Black
DL+ ML
OP GND
Button5EXIT 00
123
654
109
DOORSTATIONBVD 43F(FCPL)-3
SP+ 2SP- 3
MIC 5RX 6
GND 1
+E 4
VG 9VO 10
7TX 7
8PRG 8
to commutatordistribution amplifier
/
Note. .Connect PRG wire to GND terminal of Control Unit when memorizing MASTER-key No1Remember to disconnect PRG wire after MASTER-key No1 has been memorized.
4 51 3 62 7 89
RX
SP
-
TX
CONTROL UNITBUD-302K-20
+D
L-D
LO
P
TM
SP
+
GN
D
MIC
+E
DS
D
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
to apartment handsetsor monitors
RX
SP
-
TX
CONTROL UNITBUD-302K-20
+D
L-D
LO
P
TM
SP
+
GN
D
MIC
+E
DS
D
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
to apartment handsetsor monitors
DOORSTATIONBVD-342R
SP+ 2SP- 3
MIC 5
GND 1
+E 4
123
654
Colour
RX 6
7TX 7
V 0.6 MAX.ELECTROMECHANICAL
LOCK STRIKE/ (12 , А )
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 6 212015- ) /
Figure 7 Control Unit within the 20-apartment doorphone- BUD K-20-302
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 7 212015- ) /
Apart. 14
UKP-12(M)
Apart. 13
UKP-12(M)
Apart. 12
UKP-12(M)
Apart. 11
UKP-12(M)
Apart. 10
UKP-12(M)
Apart. 09
UKP-12(M)
Apart 8. 0
UKP-12(M)
E8-
+ D0
E9-
+ D0
E0-
+ D1
E1-
+ D1
E2-
+ D1
E3-
+ D1
E4-
+ D1
Apart. 07
UKP-12(M)
Apart.06
UKP-12(M)
Apart. 05
UKP-12(M)
Apart. 04
UKP-12(M)
Apart. 03
UKP-12(M)
Apart. 02
UKP-12(M)
Apart. 01
UKP-12(M)
E1-
+ D0
E2-
+ D0
E3-
+ D0
E4-
+ D0
E5-
+ D0
E6-
+ D0
E7-
+ D0
Apart. 20
UKP-12(M)
Apart. 19
UKP-12(M)
Apart. 18
UKP-12(M)
Apart. 17
UKP-12(M)
Apart. 16
UKP-12(M)
Apart. 15
UKP-12(M)
E5-
+ D1
E6-
+ D1
E7-
+ D1
E8-
+ D1
E9-
+ D1
E0-
+ D0
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
CONTROL UNITBUD K-20-302
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
See Fig 6.1-
Note. .F , refer toIf the number of monitors exceeds 15 pieces, then 2 power supply units needed to power the monitors
or more details RVE-4 Operating Instruction.
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 8 212015- ) /
Po
we
r lin
e
Co
axia
l C
ab
leV
ide
o lin
e
VO
VG
2
2
2
1
1
1
Power Supply Unit
(group)/12- -1BPD24 1
GND
+24V
+12V
GND2
1
Doorstation
+E
A
VG
A
GA
VO
A
VO
VG
VG
VI
+E
+E
G
GDistribution AmplifierRVE-4
+E
B
VG
B
GB
VO
B
+E
C
VG
C
GC
VO
C
+E
D
VG
D
GD
VO
D
FA FB FC FD
Z
+E
A
VG
A
GA
VO
A
VO
Z
VG
VG
VI
+E
+E
G
GDistribution AmplifierRVE-4
+E
B
VG
B
GB
VO
B
+E
C
VG
C
GC
VO
C
+E
D
VG
D
GD
VO
D
FA FB FC FD
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
CONTROL UNITBUD K-20-302
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
D0
D1
See Fig 6.1-
1 432 1 432
Apt. No 48
1 4321 432
Apt. No 49
14 32L
N-
GN
D
LN
+
VI1
+E
GN
D
Apt. No 50 Apt. No51
14 32
LN
-
GN
D
LN
+
VI1
+E
GN
D
D1
E1
D0
E9
D0
E8 234 1
MonitorVIZIT M456CVIZIT M456CMVIZIT M457M
---
D1
E0 234 1
MonitorVIZIT M440CVIZIT M440CMVIZIT M441VIZIT M441M
----
MonitorVIZIT M427C-
LN
-
GN
D
LN
+ VI
+E
MonitorVIZIT M427C-
LN
-
GN
D
LN
+ VI
+E
1 432 1 432
Apt. No 38
1 4321 432
Apt. No 39
14 32
LN
-
GN
D
LN
+
VI1
+E
GN
D
Apt. No 40 Apt. No 41
14 32
LN
-
GN
D
LN
+
VI1
+E
GN
D
D0
E1
D1
E9
D1
E8 234 1
MonitorVIZIT M456CVIZIT M456CMVIZIT M457M
---
D0
E0 234 1
MonitorVIZIT M440CVIZIT M440CMVIZIT M441VIZIT M441M
----
MonitorVIZIT M427C-
LN
-
GN
D
LN
+ VI
+E
MonitorVIZIT M427C-
LN
-
GN
D
LN
+ VI
+E
E5
D1
E7
D1
E6
D1
UKP UKP UKP
E4
D1
UKP
E2
D1
E3
D1
UKPUKP
Apt. No 52 Apt. No 53 Apt. No 54 Apt. No 55 Apt. No 56 Apt. No 57
E5
D0
E7
D0
E6
D0
UKP UKP UKP
E4
D0
UKP
E2
D0
E3
D0
UKPUKP
Apt. No 42 Apt. No 43 Apt. No 44 Apt. No 45 Apt. No 46 Apt. No 47
Figure 8 Control Unit within the 20-apartment video doorphoneBUD- K-20- 302
Co
axia
l C
ab
le
Intercom line
Po
we
r lin
e
GND conductor
PROGRAMMING
Setting Default
System Setup
Enable / disable general access code
Enable / disable individual access codes
Key / individual access code usage signaling
Unlocked state duration (1 to 20 seconds)
Lock typeH
New password for System Setup
New password for Service Settings
Entering into System Setup
MASTER-key
MASTER-key
MASTER-key
Note 1.Note 2. PRG
save all changes
The Control Unit has default settings given in the table below:
General access code
General access code and individual access codes Enabled
Type of lock Electromagnetic
Unlocked state duration seconds
Key usage signalling Enabled
Password for service settings and system setup
Doorstation volume level
P ing is performed , after all units of your doorphone / video doorphone have beenconnected Programming is accompanied with beeps and messages in the doorstation display (if any).
Symbols the
“0...9”, “#”, “ “ Dial a 4-digit password
Dial a 4-digit general access code Dial an apartment number
Dial a 3-digit individual access code Dial the digits in the picture
Unlocked state in seconds - enter a desired value Display
Beep
See the System Setup Flowchart inAppendix 1.See the Service Settings Flowchart inAppendix 2.
all apartments
This setting enables /disables beep in the handset / monitor in an apartment,when its key / individual access code is used.
the shall the e isd is d
Entering into the System Setup mode is possible with a password or the , which shall be memorized in theControl Unit beforehand (see Service Settings).
Press on the doorstation’s keypad The LED is showing:
Dial Two beeps are sounding the LED is showing:
Press system setup mode
Enter a 4-digit password or approach the close to the doorstation’s key reader.
If the dialed password is invalid, or the approached does not exist in the memory, an error beep is
sounding, and the LED is showing the message:
The default setting for password is* If the jumper in the Control Unit’s PCB is set to the position, skip action 4.
The Control Unit does not quit System Setup after change of any setting, and it is ready to continue programming. Toyou have done press Otherwise, when the power is turned off, or the button is pressed (return
to Stand-By), all changes will be lost and the system will return to its previous settings.
4230
7
1234
7
There are two programming modes: and .rogramm via the doorstation keypad
.
used in description of and :
, , - -
- -
- -
- -
-
( )
This setting determines lock and comply with lock type used: lectromagnetic lock ( )release , when voltage across its terminals is . Electromechanical lock ( ) release , when voltage is .
1. .
2. ( ),
3. ( )
4. *,
* “ ”.
.
system setup service settings
System Setup Service Settings
LЕL
1234WORK/PRG
�
�
�
�
�
�
�
�
control logicoff on
Press the buttons0 9... # �
General code
Ind.code
Password
Apart.No
9 9 9
1...20
# 9 9 9 2 Password
#
9 9 9
2
Password
�#
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 9 212015- ) /
�
�
�
�
Enable / Disable GeneralAccess Code
Enable / Disable IndividualAccess Codes
Key / IndividualAccess Code Usage Signaling
Unlocked State Duration (1 to 20 seconds)
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
the current setting is blinking)
Press
Press to return to Stand-by, or continue programming
Enter System Setup
Press
Press
Press , or continue programming
Enter System Setup
Press
Press
Press , or continue programming
Enter System Setup
Press
Press
Press , or continue programming
Enter System Setup
Press The number of
To enable the general access code, press
To disable the general access code, press
To enable individual access codes, press
To disable individual access codes, press
To enable signaling, press
To disable signaling, press
Enter a desired value from to seconds to set the unlocked state duration
for the entrance door
(
1 20
0
1
#
1
�
2
#
1
0
�
3
1
0
#
�
4
#
�
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 10212015- )
�
�
�
�
�
�
�
�
�
�
�
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
Lock Type
New Password For System Setup
New Password For Service Settings
Service Settings
Entering Into Service Settings Mode
MASTER-key
Enter System Setup
Press
To select an electromagnetic lock, press
To select an electromechanical lock, press
Press
Press , or continue programming
Enter System Setup
Press
Press
Press , or continue programming
Enter System Setup
Press
Press
Press , or continue programming
Entering into the Service Settings mode is possible with a password or the ,which shall be memorized inthe Control Unit beforehand (see Service Settings).
Dial a new 4-digit password to enter the System Setup mode
Dial a new 4-digit password to enter the Service Settings mode
(for each apartment)
MASTER-keys enable the Service Settings mode without using the password.The maximal number of MASTER-keys is 5 keys.
New general access code programming
New individual access code programming
Key memorizing
Key erasing
MASTER-key memorizing
MASTER-key erasing
Doorstation volume level adjustment
Enable / disable calls to apartment
7
1
0
#
�
8
#
�
9
#
�
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 11 212015- ) /
1.
2.
3.
4. *,
* “ ”.
1.
2.
3.
4.
1.
2.
3.
4.
5.
6.
7.
1.
2.
3.
4.
Press
Dial
Press (the service settings mode)
Enter a 4-digit password or approach the close to the doorstation’s key reader.
If the dialed password is invalid, or the approached does not exist in the memory, an error beep is
sounding, and the LED is showing the message:
The default setting for password is* If the jumper in the Control Unit’s PCB is set to the position, skip action 4.
Enter Service Settings
Press
Enter a new 4-digit general access code
Press to return to Stand-By
Enter Service Settings
Press
Dial an apartment number (1-3 digits)
Press to return to Stand-By
allows to memorize per apartment at most.
Enter Service Settings
Press
MASTER-key
MASTER-key
Note 1.Note 2. PRG
Key Memorizing
BUD-302K-20 6 keys
1234WORK/PRG
�
�
�
New GeneralAccess Code Programming
New Individual Access Code Programming
Note
Note
After a 1-2 digit number, press
. If the number is 3 digits, do not press
Dial digits of a new individual access code
Repeat actions 3 to 5 to program individual access codes for more apartments
Dial the number of apartment to which the key will be allotted
After a 1-2 digit number, press
. If the number is 3 digits, do not press
If there are available memory cells for key memorizing:
If there are no available memory cells:
three
# 19 9 9 Password
#
9 9 9
1
Password
1
General code
�
2
Apart.No
#
Ind.code
#
�
3
Apart.No
#
#
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 12 212015- ) /
5.
-
-
-
6.
7.
1.
2.
3.1
-
3.2
- -
4.
1.
2.
3.
4.
-
5.
the key has been memorized
Approach the next key to the doorstation’s key reader.
At memorizing the 6th key
If the key already exists in the memory
Press
Enter Service Settings
Press
Erase
this key has been erased from the memory
Approach the next key to be erased, if needed, etc.
Press all keys for this apartment have been erased
if needed, etc.
Press
Enter Service Settings
Press
the MASTER-key has been memorized
�
�
Key Erasing
single keys
MASTER-key Memorizing
Approach a key close to the doorstation key reader
Repeat actions 3 to 5 to record keys for more apartments
If you want to memorize less than 6 keys per one apartment, then after you have recorded the desired number ofkeys, dial the next apartment number and go through actions 4, 5.
You can delete a from the memory, or for a particular apartment at once.
Approach the key you want to erase close to the doorstation key reader
If the key does not exist in the memory:
Erase for a particular apartment
Dial the number of apartment
Dial the number of next apartment to erase all its keys,
Dial a number from 0 to 4 of the MASTER-key-to-be, e.g. 3
Approach a blank key close to the doorstation’s key-reader
Repeat actions 3 to 4 to memorize more
Press
Note.
single key all keys
all keys
MASTER-keys
�
4
Apart.No
#
�
5
�
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 13 212015- ) /
�
�
�
1.
2.
3.
4. -
5.
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5. :
- .
- .
6.
7.
Enter Service Settings
Press
Press the MASTER-key has been erased
Press to return to Stand-By
Enter Service Settings
Press
button
For example, press
Enter Service Settings
Press
Dial the apartment number to enable / disable calls
After a 1-2 digit number press
If the number is 3 digits, do not press
Press one of the following buttons
to disable calls to this apartment
to enable calls to this apartment
Press
Important!
MASTER-key Erasing
MASTER-keys
Doorstation VolumeAdjustment
7
Enable / Disable Calls ToApartment
System Setup Service SettingsWORK
Dial the number from 0 to 4 of the MASTER-key to be erased, e.g. 3
Repeat actions 3 to 4 to erase more
To adjust the doorstation’s volume, two persons are required. One person shall be at the doorstation, another one (thesubscriber) - at any apartment handset / monitor.
Dial the apartment number e.g. No. 3
The apartment handset / monitor is ringing in this apartment
The subscriber picks up the handset. The doorstation’s LED is showing:
the default setting -
To set the desired volume, press any from to on the keypad during intercom
The button sets the minimal volume, the button sets the maximal volume
To return to Stand-By, press on the doorstation’s keypad, or the subscriber shall hang up the handset.
on the Control Unit’s PCB.doorstation’s
Repeat actions 3 to 5 to enable / disable calls to more apartments
Setting a new individual access code automatically enables calls to the apartment.
When finished with the and , make sure that the jumper is moved back to theposition.
( )
If acoustic feedback results in whistling, adjust trimmer resistorIf whistling still persists, decrease the volume.
BALANCE
WORK/PRG
6
#
�
7
Apart.No
90
�
5
0 9
8
Apart.No
#
0
1
�
#
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 14 212015- ) /
FUNCTIONAL CHECK AND ADJUSTMENT
After installation and electric wiring complete, disconnect temporarily any of apartment handsets from. Connect a test handset instead of disconnected one observing polarity. Note that the test handset be
hung up.
Turn the power on. Dialthe apartment number where the test handset is
Pick up the handset. Check intercom between the doorstation and handset.
The lock releases for set in System Setup
.
have been theControl Unit the shall
Press the button on the handset / monitor. the period of time the ( to
seconds), the doorstation is showing:
While the button remains pressed, the doorstation is beeping, signaling that the door is unlocked. The beeps stop afterthe button is released.
signaling that the door is now unlocked. Open S B
Open
Open
1 20
OPERATION
Press the button on the doorstation. Doorstation produces a beep at pressing any button.set is ringing in n.
Hang up the handset (or press the button on the doorstation keypad). The doorphone goes to the Stand-By mode.
Adjust the doorstation volume, if needed (see the section)
estore the
Program the general access code and individual access codes, if needed.
Check the general access code and individual access codes for door unlocking function see the section)
Memorize keys and check their door unlocking function.
If the access code is invalid, the dialed apartment number does not exist, or the key approached to the reader is not foundin the memory, the doorstation produces an error beep. The doorphone goes to the Stand-By mode in To forcethe Stand-By mode immediately, press
subscriber dial the apartment number is ringing in. The subscriber picks up the handset to start intercom. Talk to the subscriber.
the the doorstationis beeping,
To unlock the entrance door with the general access code, press , then , then dial the code. If the code is valid, thedoor unlocks, the doorstation is beeping, and the LED is showing .
In case of an error, press and redial.
To unlock the entrance door with the individual access code, dial the sequence of your apartment number, and yourindividual access code . The apartment handset / monitor in your apartment gives a short beep (if this optionis enabled, see the section). If the code is valid, the door unlocks, the doorstation is beeping, andthe LED is showing .
In case of an error, press and redial.
your , approach closeThe apartment handset / monitor in your apartment gives a short beep (if this
option is enabled, see the section). the key an error beep is sounding.
.
D for .
.Acall sound both the test handset and doorstatio
Disconnect the test handset and r apartment handset / monitor.
One by one, check all connected handsets / monitors for intercom, video (for monitors) and remote door unlockingfunction.
( .
..
To make a call to a , . Acall sound both the apartment handset / monitorand doorstation
To release the door lock, the subscriber presses the button on handset / monitor. The door unlocks,the door and enter. To return the doorphone to the tand- y mode,
the subscriber hangs up the handset.
the door and enter.
the door and enter.
To unlock the door by means of key it to the reader - one short beep means that the key is read. If itscode is , the door unlocks.
If code is ,
To unlock the door from inside of the building, press the button
oor unlocking signals and key usage signals do not sound during intercom the line is busy
Service Settings
OPERATION
5 seconds
SYSTEM SETUP
SYSTEM SETUP
.
without pauses
found in the memorynot found
EXIT
Note
�
�
�
�
�
�
#
#
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 15 212015- ) /
Programming New IndividualAccess Codes By Subscribers
6without pauses
until a beep
SPECIFICATIONS
pcs.
pcs.
s
MOSFET
VDC
Ohms
230 VAC
W
mmmm
mm
kg
OPERATING CONDITIONS
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
:
" " " " :--
(1 .)
Max. allowable impedance of intercom line
---
Ambient temperature range:
Relative humidity of air:
The person in the apartment picks up the handset and presses the button times*. The doorstation beeps.* For apartment handsets - press .For monitors - press & hold .
Dial 3 digits of your new code. The doorstation beeps. Inform the person in the apartment that the new code has beendialed (intercom is still available).
Max. number of subscribers
Max. number of keys per apartment
Max. number of keys total)
Unlocked state duration to
Lock control
Lock control parameters across terminalsnonregulated voltageload current
Max. switchable current sec in lock’s circuitry
Operating voltage at Hz
Power consumption
Dimensionswidthheightdepth
Weight
to
to at
20
6
600
1 20
+DL -DL12 ± 1.20.6А
1.5А
DC 30
50
30
18811462
1.1
1°C 45°C
93% 25°C
(
Subscribers can easily program new individual access codes without entering the Service Settings mode. To do this,make sure that the following options - calls to your apartment ( ) and use of individual access code( ) - are enabled for your apartment.
The procedure is carried out by two persons. One person shall be at the doorstation, another one - at the apartmenthandset / monitor in the apartment.
Dial your apartment number.
The presses on the apartment handset / monitor.
To finish, press , or the other person hangs up the handset.
Service SettingsSystem Setup
person in the apartment
�
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 16 212015- ) /
Enable / Disable General Access Code
Appendix 1
Flowchart To Perform System Setup
Enable / Disable Individual Access Codes
1
�� ����
0
Enable
Disable
2
Key / Individual Access Code Usage Signaling
1
�� ����
0
Enable
Disable
3
1
1 �� ����
0
Enable
Disable
Unlocked State Durationto seconds(1 20 )
�� ����4 1...20
9 9 9 ���� ����
Password
# 2MASTER-key
Enter System Setup
��
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 17 212015- ) /
����#
ConfirmChanges
Appendix 1 continued
Lock Type
1
����
0
Electromagnetic lock
Electromechanical lock
��7
New Password For System Setup
New Password For Service Settings
�� ����Password9
�� ����8 Password
�To cancel System Setup at any moment and return to Stand-By, press
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 18 212015- ) /
9 9 9 ���� ����
Password
#MASTER-key
Enter Service Settings
New General Access Code Programming
Appendix 2
Flowchart To Perform Service Settings
3
1 ��
1 �� General code ����
New Individual Access Codes Programming
�� ����2 Apart.No Ind.code# ��
Key Memorizing
�� Apart.No #
��������
��
Approachkey
Has been memorized
Already exists
����
������
��������
All 6 keys have been memorized
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 19 212015- ) /
Appendix 2 continued
Key Erasing
��
Apart.No #
Approachkey
Has been erased
Does not exist
����
������
All keys for this apartment have been erased
4
����
MASTER-key Memorizing
��5
6
( )E.g. 3
0...4 ��
Approach key����
MASTER-key Erasing
��
( )E.g. 3
0...4 �� ����#
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 20 212015- ) /
Appendix 2 continued
Doorstation Volume Adjustment
��
( )E.g. 3
7 Apart.NoPick uphandset
( )E.g. 5
0...9
Enable / Disable Calls To Apartment
��8 Apart.No ��#
1
����
0
Enable
Disable
�To cancel Service Settings at any moment and return to Stand-By, press
www.vizit-group.com BUD-302K-20 Operating Instruction (revision 12 21 212015- ) /