thank you for purchasing your shed from forest garden. no ... · thank you for purchasing your shed...
TRANSCRIPT
FIXING PACK CODE: MSFP2
4 x
50m
m S
crew
sQ
TY: 4
1
4 x
40m
m S
crew
sQ
TY: 2
2
4 x
45m
m S
crew
sQ
TY: 1
9
3.5
x 30
mm
Scr
ews
QTY
: 123
3.5
x 25
mm
Scr
ews
QTY
: 43
Felt TacksQTY: 154
Flush HingesQTY: 2
Hasp & StapleQTY: 1
Z-Brackets (45mm)QTY: 4
Making British gardens great
SHED INSTRUCTIONS PENT SHEDS (6x4, 7x5, 8x6, 10x6)
Missing Something?Call our aftersales team on0333 777 7089
Need more information?Call our technical team on0333 321 3142
Visit our website for spare instructions and more informationwww.forestgarden.co.uk
FIXING PACK CONTAINS:
B
Forest Garden, Oak Drive, Hartlebury Trading Estate, Hartlebury, Worcestershire, DY10 4JB
Thank you for purchasing your shed from Forest Garden. No matter what size garden, a shed is the most practical of garden structures. Simply follow these step by step instructions and our top tips and you’ll be enjoying your shed for many years to come. If you have any questions or need advice, our friendly team is here to help.
ISSUE: 0319
BEFORE YOU START
Please read through these instructions to familiarise yourself with your shed. We recommend that you check all the components using the lists found on the front and back pages before you start to build.
All of our sheds are constructed in the same way. They simply come with different components depending on the type of shed you have. Don’t worry if your fixing pack contains some spare items at the end of the build (you haven’t missed a bit!) we have sent you a generic fixing pack to suit the shed range.
It’s vital that you build your new shed on a solid, level base. Timber or Plastic Shed Bases are ideal, as is solid concrete or concrete slabs.
We recommend using the following tools (not supplied):
If you have an existing base and think it’s suitable for your new shed to be sited on, it is important you check that it is level and doesn’t deviate by any more than 15mm from edge to edge. If this isn’t the case the building will twist, causing gaps to appear in the sections and the roof, doors and windows to misalign.
There’s more information on base preparation on our website www.forestgarden.co.uk
Assembly is relatively straightforward if your follow these step by step instructions. We recommend getting everything aligned properly before screwing together and that screw holes should be pre-drilled to avoid splitting the timber.
BASE PREPARATION
TOOLS NEEDED
Timber Base Self-constructed/
Buy pre-made
Tape Measure
Sharp Knife Pozidrive Screwdriver
Drill & 2mm Drill Bit
Hammer
ConcreteConcrete surface/
Concrete slabs
Pro Shed BaseInterlocking
eco-friendly base
SoilA base of soil
only
Broken Slabs/GapsUneven slab sizes with no cement
REMINDERAlways pre-drill before screwing.
IMPORTANTAssembly requires 2+ adults.
Ladder
2
Spirit Level
PLEASE KEEP PLASTIC BAGS AND SMALL PARTS AWAY FROM CHILDREN
MOVEMENT, TWISTING & WARPING
Wood contains a natural level of moisture so decreasing humidity levels in the surrounding air may cause panels to change their shape as the porous fibres shrink. This can be exaggerated during prolonged periods of dry weather. Movement and gaps in timber products are normal, in most cases the wood will revert to its original form once the high temperatures subside and there is more moisture content in the air. Similarly, in the winter months, the opposite may occur with wood swelling.
CARE & ATTENTION
To help you get the most out of our products it’s useful to know a little more about the properties of timber, what’s normal and how your shed may behave as the seasons change. Wood is an extremely durable material for construction but as a natural product when used outdoors it is susceptible to changes in the environment.
3
EXPANSION, CONTRACTION, SPLITS & CRACKS
All timber will expand and contract according to its environment. As a result of this expansion and contraction, it is very common to see splits and cracks developing in the wood. Splits are common during the spring and summer months as the wood begins to dry out. The outer surface dries first and contracts, contracting over a still expanded core of the wood. The result of this is that splits and cracks appear along the grain of wood. These splits are not a fault and do not affect the structural integrity of a product.
MOULD & BLUE STAIN
Mould is a surface-dwelling fungus that feeds on the nutrients and debris contained in the surface cells of timber. The most common problems associated with mould are discoloured timber and an increase in permeability of the timber. Blue stain is part of the same family but penetrates deeper into the surface layers of the timber. It stains the timber a dark blue, whereas mould is usually black. These do not cause the timber to rot. Keep the building well ventilated to avoid mould.
MAKE SURE YOU POSITION YOUR SHED IN THE BEST LOCATION IN YOUR GARDENAvoid areas where water pools and is constantly wet. Position away from trees and cut back any overhanging foliage which can cause moisture to be trapped against shed walls and debris to collect on the roof.
1
RAISE YOUR SHED OFF THE GROUNDIdeally any concrete base should be the same footprint as the shed to allow surface water to run off without pooling, a timber shed base can also be used. Raise 50mm above ground level.
2
SEAL THE BASEWe recommend a treatment containing wax or oil, paint the bearers that come into contact with the ground to prevent moisture coming up.
3
USE AN END-GRAIN PROTECTORTo protect the corners and panel joins, an end grain treatment can be applied.
4
SEAL THE PANELS & WINDOWSUse a flexible silicone sealant around windows to prevent water ingress. This can also be used where 2 sections of the shed joint together. Apply internally.
5
Treat your building annually, we advise the application of a high quality preservative that contains a mildewcide. For more information on the conditions of our guarantee see forestgarden.co.uk.
CONSIDER ADDING GUTTERSAdding guttering around the fascia of the shed will redirect rain water away from the shed’s foundation.
6
KEEP VENTILATEDGood airflow around the perimeter of the shed and regular ventilation inside the shed will help prevent mould and mildew.
7
CONSIDER A WEATHERPROOFING STAIN OR CLEAR TREATMENTWe recommend you paint your garden shed with a weatherproofing treatment at least once a year. This will help maintain the wood, stabilise timber movement and help prolong the life of your shed.
8
TREATED TIMBER CONTAINING A BIOCIDAL PRODUCTCONTROL OF WOOD DESTROYING ORGANISMS
Active Ingredients - Propiconazole, Tebuconazole, IPBC, Permethrine, Benzyl-C12-16-Alkyldimethyl Chlorides. (Dip Treated Sheds)Basic Copper Carbonate, DDA Carbonate, DDA Chloride. (Pressure Treated Sheds)
Wear gloves when handling. Avoid inhalation of sawdust. Do not use in contact with drinking water or food. Do not use for animal bedding or in fish ponds. Dispose of treated wood responsibly.
THINGS THAT YOU MIGHT SEE IN YOUR PRODUCT
8 TOP TIPS TO ENSURE YOUR SHED IS FULLY WATERPROOF
THE ROOF OF THIS BUILDING IS NOT A LOAD BEARING STRUCTURE
ADVICE ON FELT HANDLING & USAGE
Roofing felt is flexible at temperatures above 5°C. In cold temperatures extra care must be taken when handling and installing to prevent cracking and damage to the felt. The felt should not be rolled, folded or used in temperatures lower than 5° C. In cold temperatures the felt should be stored above 10°C (indoors) for 24 hours prior to use. Felt must be lifted, not dragged and should be stored on its end on a dry surface.
C
C
C
C
DD G
H B
PENT
10’
6’
DD
E
FF PENT
6’
4’
H
G D
CC
AA
PENT
7’
5’
GG
H
C
C
C
C
PENT
8’
6’
PENT SHED
F 4ft Panel (1180 x 1603mm)
A 2ft Panel (590 x 1603mm)
B 2ft Panel (590 x 1945mm)
C 3ft Panel (885 x 1603mm)
D 3ft Panel (885 x 1717mm)
E 3ft Panel (885 x 1945mm)(With windows)
KEY
G 4ft Panel (1180 x 1717mm)
H 4ft Panel (1180 x 1945mm)(With windows)
IDENTIFY YOUR SHED
From the section layout below, identify your shed based on the width and depth dimensions of your shed – eg 6x4. You’ll need this to identify the side panel positions.
Assembly of your chosen shed will slightly differ throughout the steps based on the size of your shed. This will be mentioned throughout the instructions for guidance.
PLEASE NOTEThe sheds are made up of multiple sections where same size panels are interchangeable.
4
The door is flexible for all shed types and can be hinged onto either side.
Indicates the panel orientation during construction. This will apply to all of the corners for your chosen shed.
EG. DOOR FRAME
EG. INSIDE CORNER
1a
1b
1c
CONSTRUCTION1
Start at a back corner. See the section layout on page 4 to confirm position. Secure the corner as shown below.
Repeat the process for remaining panels and secure panels together. Make sure that the
bottom frame of the wall panel rests on the outer edge of the floor.
Secure the panels into place by screwing into the floor. Screw into the door frame in the door
panel into the floor to keep secure.
Attach the Triangular Pent Section by screwing to the wall panel. Also screw from the front panel into the Triangular Pent Section to keep it more secure as shown below. Repeat for the other Triangular Pent Section.
5
EG. INTO FLOOREG. SIDES
Layout the panels around your shed base. We recommend to start in a back corner then work from the back panels
to the front panels for assembly.
FLOORS & SIDESPRE-DRILL
WITH 2MM BIT FOR ALL STEPS
BELOW.
Position the floor in your desired location. The 6x4 and 7x5 sheds will only have one floor. For the 8x6 and 10x6 sheds, turn the floors upside down to secure the sections together by screwing
through the adjoining bearers. 8x6 and 10x6 will have two floors.
8X6 & 10X6 SHEDS
6X4 & 7X5 SHEDS
SIDE PANEL
BACK PANEL
3
4
WINDOWS2Secure windows by screwing through the window cover strips and window into the panel frame. Screw into the bottom of the window
and into the interior sill to keep secure. Make sure the window is centralised for all window frames as shown below.
WINDOW POSITIONING
6
WINDOW
SITS ONTO INTERIOR SILL
OUTSIDE INSIDE
PRE-DRILL WITH 2MM BIT FOR ALL STEPS
BELOW.
OUTSIDE
COVER AND DOOR STRIPSSecure the door weather strip
onto the side you want the hinges, and ensure it’s flush to the floor and against the face of the wall
panel framing.
SLAMMING STRIP(28 x 12 x 1637)COVER STRIPS(See pages 8-9 for measurement for chosen shed)
Attach the cover strips onto the corners. Ensuring they are
flush to the bottom edge of the panels as shown below.
Attach the cover strips onto the adjoining panels. Ensuring it is
flush to the bottom edge of the panels as shown below.
Attach the slamming strip onto the opposite side you want the hinges, onto the wall panel shown below.
DOOR WEATHER STRIP(38 x 12 x 1710)
OUTSIDE INSIDE INSIDE
PLEASE NOTE
Screwing the door weather strip onto the
wall panel determines the side of
your hinges.
PRE-DRILL WITH 2MM BIT FOR ALL STEPS
BELOW.
202mm
175mm
DOOR FIXINGS
TOP TIP: Line up the hasp & staple. Mark the edges with a
pencil for guidance.
Fix the Hasp and Staple as shown. Ensure the screws go into the framework behind.
FRAMEWORK
DOOR FACE
NOTCH IN LINE WITH DOOR FACE
DO
OR
Make sure the outer face of the notch on the hinge is in line with the door face.
HASP & STAPLE POSITIONING
PRE-DRILL WITH 2MM BIT FOR ALL STEPS
BELOW.
Attach 2 hinges onto the door frame with the measurements provided. Please take note
of the hinge position shown below.
Place the door into the opening, ensuring it’s level. Make sure the hinges
are up against the door weather strip face.
5mm
Allow a 5mm gap at the top when placing door.
HINGE POSITION
DOOR
OUTSIDE
WALL PANEL FRAME
DOOR WEATHER
STRIP
5a
5b
5c
ROOF
1032.5mm885mm
6x4 MEASUREMENTS
7x5 MEASUREMENTS )(
715.8mm
783mm
715.8mm
942mm
931mm
931mm
8x6 MEASUREMENTS
10x6 MEASUREMENTS )(
50m
m
TOP TIP: Use measuring tape to measure out equal lengths & cut with a sharp knife. Hammer the
tacks into the felt. Add the tacks at 150mm intervals.
5
1375mm
(6x4 Measurement)
1688mm
(7x5 Measurement)
Z-BRACKET
Attach the Z-brackets with screws onto the top face at each end of the
beam(s).
For the 6x4 and 7x5 sheds, you will have only one beam. Screw the Z-brackets to the centre of the front and back panels (measurements shown below). Ensure the Z-brackets are facing the right
way as shown below.
For the 8x6 and 10x6 sheds, you will have two beams. Use the measurements below to space them across the front and back panels and screw as shown below. Ensure the Z-brackets are facing the right way
as shown below.
2032mm
(8x6 & 10x6 Measurement)
Before screwing the OSB roof sheets onto the roof, screw the roof support strips to the OSB roof
sheets. Ensure they are flush to the edges. Repeat this for both sides. The measurements shown below are to show the orientation of the sheets. The strip(s) will be the same length as the 2 edges when joined
together as shown below.
8X6 & 10X6 SHEDS
6X4 & 7X5 SHEDS
6X4 & 7X5 SHEDS 8X6 & 10X6 SHEDS
For the 6x4 and 7x5 sheds, screw the shorter roof support strips central onto the sheets. For the 8x6 and 10x6 sheds,
screw the shorter roof support strips into the space provided as shown below.
Repeat this for both sides and ensure they are flush to the sheet edges.
6X4 & 7X5 SHEDS
8X6 & 10X6 SHEDS
PRE-DRILL WITH 2MM BIT FOR ALL STEPS
BELOW.
Measure out equal lengths based on your chosen shed and overlap it on the top, around the edges and fold the corners; tack to keep secure as shown below. Ensure 50mm at the
bottom and work from the bottom to the top.
8X6 & 10X6 SHEDS
6X4 & 7X5 SHEDS
Secure the fascias with screws as shown below The fascia options differ based on your chosen
shed. The parts that are left over are an indiciation on which steps to follow. Use pages 8-9 for
measurement guidance.
Once the roof support strips are screwed onto the front and back of the OSB roof sheets, push the sheets forward from the back, ensuring the roof support strip is in contact with the shed as shown below. Then screw the OSB roof sheets
into the beam(s) and shed frame.
6X4 & 7X5 SHEDS
7
Place the OSB roof sheets, one at a time onto the shed frame and
beams. Ensure where the OSB roof sheets join, are central for each
beams.
8X6 & 10X6 SHEDS
TOP TIP: Mark onto the OSB sheet and draw a line to ensure you drill and screw into the beam(s).
SELE
CT
YO
UR
CH
OSE
N S
HE
D &
CH
EC
K Y
OU
HA
VE
ALL
YO
UR
PA
RTS
.
8D
IP T
RE
ATE
D P
EN
T SH
ED
S
(The
par
ts d
o n
ot
have
co
des
on
them
. The
y ar
e lis
ted
ab
ove
sho
uld
yo
u ne
ed t
o o
rder
one
.)
Part
Cod
eD
escr
iptio
nN
o.
Part
Cod
eD
escr
iptio
nN
o.
Part
Cod
eD
escr
iptio
nN
o.
Part
Cod
eD
escr
iptio
nN
o.
OD
PMR
HA
44f
t Tria
ngul
ar P
ent S
ectio
n - R
ight
Han
d1
OD
PMR
HA
55f
t Tria
ngul
ar P
ent S
ectio
n - R
ight
Han
d1
OD
PMR
HA
66f
t Tria
ngul
ar P
ent S
ectio
n - R
ight
Han
d1
OD
PMR
HA
66f
t Tria
ngul
ar P
ent S
ectio
n - R
ight
Han
d1
OD
PMLH
A4
4ft T
riang
ular
Pen
t Sec
tion
- Lef
t Han
d1
OD
PMLH
A5
5ft T
riang
ular
Pen
t Sec
tion
- Lef
t Han
d1
OD
PMLH
A6
6ft T
riang
ular
Pen
t Sec
tion
- Lef
t Han
d1
OD
PMLH
A6
6ft T
riang
ular
Pen
t Sec
tion
- Lef
t Han
d1
OD
PM88
5BP
Sect
ion
D -
3ft P
ent B
ack
Pane
l (8
85 x
171
7mm
)2
OD
PM88
5BP
Sect
ion
D -
3ft P
ent B
ack
Pane
l (8
85 x
171
7mm
)1
OD
PM11
80B
PSe
ctio
n G
- 4f
t Pen
t Bac
k Pa
nel
(118
0 x
1717
mm
)2
OD
PM88
5BP
Sect
ion
D -
3ft P
ent B
ack
Pane
l (8
85 x
171
7mm
)2
OD
M88
5TW
PSe
ctio
n E
- 3ft
Pent
Fro
nt W
indo
w P
anel
(885
x 1
945m
m)
1O
DPM
1180
BP
Sect
ion
G -
4ft P
ent B
ack
Pane
l (1
180
x 17
17m
m)
1O
DM
885P
PSe
ctio
n C
- 3f
t Pan
el (8
85 x
160
3mm
)4
OD
PM11
80B
PSe
ctio
n G
- 4f
t Pen
t Bac
k Pa
nel
(118
0 x
1717
mm
)1
OD
M88
5TD
P3f
t Pen
t Fro
nt D
oor P
anel
(8
85 x
194
5mm
)1
OD
M88
5TD
P3f
t Pen
t Fro
nt D
oor P
anel
(8
85 x
194
5mm
)1
OD
M11
80TW
PSe
ctio
n H
- 4f
t Pen
t Fro
nt W
indo
w P
anel
(118
0 x
1945
mm
)1
OD
M88
5PP
Sect
ion
C -
3ft P
anel
(885
x 1
603m
m)
4
OD
M11
80PP
Sect
ion
F - 4
ft Pa
nel (
1180
x 1
603m
m)
2O
DM
885P
PSe
ctio
n C
- 3f
t Pan
el (8
85 x
160
3mm
)2
OD
M11
80TD
P4f
t Pen
t Fro
nt D
oor P
anel
(8
85 x
194
5mm
)1
OD
M59
0TPP
Sect
ion
B -
2ft P
ent F
ront
Pan
el (5
90 x
194
5mm
)1
MSD
DR
Doo
r1
OD
M59
0PP
Sect
ion
A - 2
ft Pa
nel (
590
x 16
03m
m)
2M
SDD
RD
oor
1O
DM
1180
TWP
Sect
ion
H -
4ft P
ent F
ront
Win
dow
Pan
el (1
180
x 19
45m
m)
1
MSB
FL46
Floo
r1
OD
M11
80TW
PSe
ctio
n H
- 4f
t Pen
t Fro
nt W
indo
w P
anel
(118
0 x
1945
mm
)1
MSB
FL46
Floo
r2
OD
M11
80TD
P4f
t Pen
t Fro
nt D
oor P
anel
(8
85 x
194
5mm
)1
2812
1637
PDT
Slam
min
g St
rip (2
8x12
x163
7mm
)1
MSD
DR
Doo
r1
2812
1637
PDT
Slam
min
g St
rip (2
8x12
x163
7mm
)1
MSD
DR
Doo
r1
2816
0550
DT
Win
dow
Cov
er S
trip
(28x
16x5
50m
m)
3M
SBFL
57Fl
oor
128
1605
50D
TW
indo
w C
over
Stri
p (2
8x16
x550
mm
)3
MSB
FL56
Floo
r2
2828
0973
Roo
f Sup
port
Strip
(28x
28x9
73m
m)
228
1216
37PD
TSl
amm
ing
Strip
(28x
12x1
637m
m)
128
2809
88R
oof S
uppo
rt St
rip (2
8x28
x988
mm
)4
2812
1637
PDT
Slam
min
g St
rip (2
8x12
x163
7mm
)1
2828
1934
Roo
f Sup
port
Strip
(28x
28x1
934m
m)
228
1605
50D
TW
indo
w C
over
Stri
p (2
8x16
x550
mm
)3
2828
1242
Roo
f Sup
port
Strip
(28x
28x1
242m
m)
428
1605
50D
TW
indo
w C
over
Stri
p (2
8x16
x550
mm
)3
3812
1710
PDT
Wea
ther
Stri
p (3
8x12
x171
0mm
)1
2828
1115
Roo
f Sup
port
Strip
(28x
28x1
115m
m)
638
1217
10PD
TW
eath
er S
trip
(38x
12x1
710m
m)
128
2809
88R
oof S
uppo
rt St
rip (2
8x28
x988
mm
)4
4416
1695
DT
Cov
er S
trip
(44x
16x1
695m
m)
338
1217
10PD
TW
eath
er S
trip
(38x
12x1
710m
m)
144
1616
95D
TC
over
Stri
p (4
4x16
x169
5mm
)3
2828
1537
Roo
f Sup
port
Strip
(28x
28x1
537m
m)
444
1619
25D
TC
over
Stri
p (4
4x16
x192
5mm
)3
4416
1695
DT
Cov
er S
trip
(44x
16x1
695m
m)
344
1618
10D
TC
over
Stri
p (4
4x16
x181
0mm
)2
3812
1710
PDT
Wea
ther
Stri
p (3
8x12
x171
0mm
)1
4545
1153
PAII7
9R
oof B
eam
144
1618
10D
TC
over
Stri
p (4
4x16
x181
0mm
)2
4416
1925
DT
Cov
er S
trip
(44x
16x1
925m
m)
344
1616
95D
TC
over
Stri
p (4
4x16
x169
5mm
)4
5912
1390
PDT
Fasc
ia (5
9x12
x139
0mm
)2
4416
1925
DT
Cov
er S
trip
(44x
16x1
925m
m)
345
4517
83PA
II83
Roo
f Bea
m2
4416
1810
DT
Cov
er S
trip
(44x
16x1
810m
m)
259
1219
78PD
TFa
scia
(59x
12x1
978m
m)
145
4514
41PA
II81
Roo
f Bea
m1
5912
1020
PDT
Fasc
ia (5
9x12
x102
0mm
)4
4416
1925
DT
Cov
er S
trip
(44x
16x1
925m
m)
4R
PET8
85W
indo
w2
5912
1132
PDT
Fasc
ia (5
9x12
x113
2mm
)2
5912
1259
PDT
Fasc
ia (5
9x12
x125
9mm
)2
4545
1783
PAII8
3B
eam
2O
SB13
7596
78O
SB S
heet
- R
oof
259
1216
88PD
TFa
scia
(59x
12x1
688m
m)
2R
PET5
90W
indo
w2
5912
1020
PDT
Fasc
ia (5
9x12
x102
0mm
)4
FELT
44B
LFe
lt1
RPE
T590
Win
dow
2O
SB20
3282
88O
SB S
heet
- R
oof
359
1215
55PD
TFa
scia
(59x
12x1
555m
m)
2O
SB16
8811
158
OSB
She
et -
Roo
f2
FELT
81B
LFe
lt1
RPE
T590
Win
dow
2FE
LT78
BL
Felt
1O
SB10
2510
168
OSB
She
et -
Roo
f3
8505
2Fe
lt1
Part
Cod
eD
escr
iptio
nN
o.
Part
Cod
eD
escr
iptio
nN
o.
SDPM
RH
A4
4ft T
riang
ular
Pen
t Sec
tion
- Rig
ht H
and
1SD
PMR
HA
55f
t Tria
ngul
ar P
ent S
ectio
n - R
ight
Han
d1
SDPM
LHA
44f
t Tria
ngul
ar P
ent S
ectio
n - L
eft H
and
1SD
PMLH
A5
5ft T
riang
ular
Pen
t Sec
tion
- Lef
t Han
d1
SDPM
885B
PSe
ctio
n D
- 3f
t Pen
t Bac
k Pa
nel
(885
x 1
717m
m)
2SD
PM88
5BP
Sect
ion
D -
3ft P
ent B
ack
Pane
l (8
85 x
171
7mm
)1
SDM
885T
WP
Sect
ion
E - 3
ft Pe
nt F
ront
Win
dow
Pan
el (8
85 x
194
5mm
)1
SDPM
1180
BP
Sect
ion
G -
3ft P
ent B
ack
Pane
l (1
180
x 17
17m
m)
1
SDM
885T
DP
3ft P
ent F
ront
Doo
r Pan
el
(885
x 1
945m
m)
1SD
M88
5TD
P3f
t Pen
t Fro
nt D
oor P
anel
(8
85 x
194
5mm
)1
SDM
1180
PPSe
ctio
n F
- 4ft
Pane
l (11
80 x
160
3mm
)2
SDM
885P
PSe
ctio
n C
- 3f
t Pan
el (8
85 x
160
3mm
)2
MSD
DR
Doo
r1
SDM
590P
PSe
ctio
n A
- 2ft
Pane
l (59
0 x
1603
mm
)2
MSB
FL46
Floo
r1
SDM
1180
TWP
Sect
ion
H -
4ft P
ent F
ront
Win
dow
Pan
el (1
180
x 19
45m
m)
128
1205
50PD
TW
indo
w C
over
Stri
p (2
8x12
x550
mm
)3
MSD
DR
Doo
r1
2812
1637
PDT
Slam
min
g St
rip (2
8x12
x163
7mm
)1
MSB
FL57
Floo
r1
2828
0973
Roo
f Sup
port
Strip
(28x
28x9
73m
m)
228
1205
50PD
TW
indo
w C
over
Stri
p (2
8x12
x550
mm
)3
2828
1934
Roo
f Sup
port
Strip
(28x
28x1
934m
m)
228
1216
37PD
TSl
amm
ing
Strip
(28x
12x1
637m
m)
138
1217
10PD
TW
eath
er S
trip
(38x
12x1
710m
m)
128
2811
15R
oof S
uppo
rt St
rip (2
8x28
x111
5mm
)6
4012
1695
PDT
Cov
er S
trip
(40x
12x1
695m
m)
338
1217
10PD
TW
eath
er S
trip
(38x
12x1
710m
m)
140
1219
25PD
TC
over
Stri
p (4
0x12
x192
5mm
)3
4012
1695
PDT
Cov
er S
trip
(44x
12x1
695m
m)
345
4511
53PA
II79
Roo
f Bea
m1
4012
1810
PDT
Cov
er S
trip
(44x
12x1
810m
m)
259
1213
90PD
TFa
scia
(59x
12x1
390m
m)
240
1219
25PD
TC
over
Stri
p (4
4x12
x192
5mm
)3
5912
1978
PDT
Fasc
ia (5
9x12
x197
8mm
)1
4545
1441
PAII8
1R
oof B
eam
1R
PET8
85W
indo
w2
5912
1132
PDT
Fasc
ia (5
9x12
x113
2mm
)2
OSB
1375
9678
OSB
She
et -
Roo
f2
5912
1688
PDT
Fasc
ia (5
9x12
x168
8mm
)2
8502
5Fe
lt1
RPE
T590
Win
dow
2O
SB16
8811
158
OSB
She
et -
Roo
f2
8501
4Fe
lt1
Ship
lap
Pent
6' x
4' -
2 W
indo
ws
(SD
P64M
)
Ove
rlap
Pent
6' x
4' -
2 W
indo
ws
(OD
P64M
)O
verla
p Pe
nt 8
' x 6
' - 2
Win
dow
s (O
DP8
6M)
Ove
rlap
Pent
10'
x 6
' - 2
Win
dow
s (O
DP1
06M
)O
verla
p Pe
nt 7
' x 5
' - 2
Win
dow
s (O
DP7
5M)
Ship
lap
Pent
7' x
5' -
2 W
indo
ws
(SD
P75M
)
9P
RE
SSU
RE
TR
EA
TED
PE
NT
SHE
DS
(The
par
ts d
o n
ot
have
co
des
on
them
. The
y ar
e lis
ted
ab
ove
sho
uld
yo
u ne
ed t
o o
rder
one
.)
SELE
CT
YO
UR
CH
OSE
N S
HE
D &
CH
EC
K Y
OU
HA
VE
ALL
YO
UR
PA
RTS
.
Part
Cod
eD
escr
iptio
nN
o.
Part
Cod
eD
escr
iptio
nN
o.
Part
Cod
eD
escr
iptio
nN
o.
Part
Cod
eD
escr
iptio
nN
o.
OPP
MR
HA
44f
t Tria
ngul
ar P
ent S
ectio
n - R
ight
Han
d1
OPP
MR
HA
55f
t Tria
ngul
ar P
ent S
ectio
n - R
ight
Han
d1
OPP
MR
HA
66f
t Tria
ngul
ar P
ent S
ectio
n - R
ight
Han
d1
OPP
MR
HA
66f
t Tria
ngul
ar P
ent S
ectio
n - R
ight
Han
d1
OPP
MLH
A4
4ft T
riang
ular
Pen
t Sec
tion
- Lef
t Han
d1
OPP
MLH
A5
5ft T
riang
ular
Pen
t Sec
tion
- Lef
t Han
d1
OPP
MLH
A6
6ft T
riang
ular
Pen
t Sec
tion
- Lef
t Han
d1
OPP
MLH
A6
6ft T
riang
ular
Pen
t Sec
tion
- Lef
t Han
d1
OPP
M88
5BP
Sect
ion
D -
3ft P
ent B
ack
Pane
l (8
85 x
171
7mm
)2
OPP
M88
5BP
Sect
ion
D -
3ft P
ent B
ack
Pane
l (8
85 x
171
7mm
)1
OPP
M11
80B
PSe
ctio
n G
- 4f
t Pen
t Bac
k Pa
nel
(118
0 x
1717
mm
)2
OPP
M88
5BP
Sect
ion
D -
3ft P
ent B
ack
Pane
l (8
85 x
171
7mm
)2
OPM
885T
WP
Sect
ion
E - 3
ft Pe
nt F
ront
Win
dow
Pan
el (8
85 x
194
5mm
)1
OPP
M11
80B
PSe
ctio
n G
- 3f
t Pen
t Bac
k Pa
nel
(118
0 x
1717
mm
)1
OPM
885P
PSe
ctio
n C
- 3f
t Pan
el (8
85 x
160
3mm
)4
OPP
M11
80B
PSe
ctio
n G
- 4f
t Pen
t Bac
k Pa
nel
(118
0 x
1717
mm
)1
OPM
885T
DP
3ft P
ent F
ront
Doo
r Pan
el
(885
x 1
945m
m)
1O
PM88
5TD
P3f
t Pen
t Fro
nt D
oor P
anel
(8
85 x
194
5mm
)1
OPM
1180
TWP
Sect
ion
H -
4ft P
ent F
ront
Win
dow
Pan
el (1
180
x 19
45m
m)
1O
PM88
5PP
Sect
ion
C -
3ft P
anel
(885
x 1
603m
m)
4
OPM
1180
PPSe
ctio
n F
- 4ft
Pane
l (11
80 x
160
3mm
)2
OPM
885P
PSe
ctio
n C
- 3f
t Pan
el (8
85 x
160
3mm
)2
OPM
1180
TDP
4ft P
ent F
ront
Doo
r Pan
el
(885
x 1
945m
m)
1O
PM59
0TPP
Sect
ion
B -
2ft P
ent F
ront
Pan
el (5
90 x
194
5mm
)1
MSP
DR
Doo
r1
OPM
590P
PSe
ctio
n A
- 2ft
Pane
l (59
0 x
1603
mm
)2
MSP
DR
Doo
r1
OPM
1180
TWP
Sect
ion
H -
4ft P
ent F
ront
Win
dow
Pan
el (1
180
x 19
45m
m)
1
MSB
FL46
Floo
r1
OPM
1180
TWP
Sect
ion
H -
4ft P
ent F
ront
Win
dow
Pan
el (1
180
x 19
45m
m)
1M
SBFL
46Fl
oor
2O
PM11
80TD
P4f
t Pen
t Fro
nt D
oor P
anel
(8
85 x
194
5mm
)1
2812
1637
PPT
Slam
min
g St
rip (2
8x12
x163
7mm
)1
MSP
DR
Doo
r1
2812
1637
PPT
Slam
min
g St
rip (2
8x12
x163
7mm
)1
MSP
DR
Doo
r1
2816
0550
PTW
indo
w C
over
Stri
p (2
8x16
x550
mm
)3
MSB
FL57
Floo
r1
2816
0550
PTW
indo
w C
over
Stri
p (2
8x16
x550
mm
)3
MSB
FL56
Floo
r2
2828
0973
Roo
f Sup
port
Strip
(28x
28x9
73m
m)
228
1216
37PP
TSl
amm
ing
Strip
(28x
12x1
637m
m)
128
2809
88R
oof S
uppo
rt St
rip (2
8x28
x988
mm
)4
2812
1637
PPT
Slam
min
g St
rip (2
8x12
x163
7mm
)1
2828
1934
Roo
f Sup
port
Strip
(28x
28x1
934m
m)
228
1605
50PT
Win
dow
Cov
er S
trip
(28x
16x5
50m
m)
328
2812
42R
oof S
uppo
rt St
rip (2
8x28
x124
2mm
)4
2816
0550
PTW
indo
w C
over
Stri
p (2
8x16
x550
mm
)3
3812
1710
PPT
Wea
ther
Stri
p (3
8x12
x171
0mm
)1
2828
1115
Roo
f Sup
port
Strip
(28x
28x1
115m
m)
638
1217
10PP
TW
eath
er S
trip
(38x
12x1
710m
m)
128
2809
88R
oof S
uppo
rt St
rip (2
8x28
x988
mm
)4
4416
1695
PTC
over
Stri
p (4
4x16
x169
5mm
)3
3812
1710
PPT
Wea
ther
Stri
p (3
8x12
x171
0mm
)1
4416
1695
PTC
over
Stri
p (4
4x16
x169
5mm
)3
2828
1537
Roo
f Sup
port
Strip
(28x
28x1
537m
m)
444
1619
25PT
Cov
er S
trip
(44x
16x1
925m
m)
344
1616
95PT
Cov
er S
trip
(44x
16x1
695m
m)
344
1618
10PT
Cov
er S
trip
(44x
16x1
810m
m)
238
1217
10PP
TW
eath
er S
trip
(38x
12x1
710m
m)
145
4511
53PA
II79
Roo
f Bea
m1
4416
1810
PTC
over
Stri
p (4
4x16
x181
0mm
)2
4416
1925
PTC
over
Stri
p (4
4x16
x192
5mm
)3
4416
1695
PTC
over
Stri
p (4
4x16
x169
5mm
)4
5912
1390
PPT
Fasc
ia (5
9x12
x139
0mm
)2
4416
1925
PTC
over
Stri
p (4
4x16
x192
5mm
)3
4545
1783
PAII8
3R
oof B
eam
244
1618
10PT
Cov
er S
trip
(44x
16x1
810m
m)
259
1219
78PP
TFa
scia
(59x
12x1
978m
m)
145
4514
41PA
II81
Roo
f Bea
m1
5912
1020
PPT
Fasc
ia (5
9x12
x102
0mm
)4
4416
1925
PTC
over
Stri
p (4
4x16
x192
5mm
)4
RPE
T885
Win
dow
259
1211
32PP
TFa
scia
(59x
12x1
132m
m)
259
1212
59PP
TFa
scia
(59x
12x1
259m
m)
245
4517
83PA
II83
Bea
m2
OSB
1375
9678
OSB
She
et -
Roo
f2
5912
1688
PPT
Fasc
ia (5
9x12
x168
8mm
)2
RPE
T590
Win
dow
259
1210
20PP
TFa
scia
(59x
12x1
020m
m)
4FE
LT44
BL
Felt
1R
PET5
90W
indo
w2
OSB
2032
8288
OSB
She
et -
Roo
f3
5912
1555
PPT
Fasc
ia (5
9x12
x155
5mm
)2
OSB
1688
1115
8O
SB S
heet
- R
oof
2FE
LT81
BL
Felt
1R
PET5
90W
indo
w2
FELT
78B
LFe
lt1
OSB
2032
1025
8O
SB S
heet
- R
oof
385
052
Felt
1
Ove
rlap
Pent
6' x
4' -
2 W
indo
ws
(OPP
64M
)O
verla
p Pe
nt 7
' x 5
' - 2
Win
dow
s (O
PP75
M)
Ove
rlap
Pent
8' x
6' -
2 W
indo
ws
(OPP
86M
)O
verla
p Pe
nt 1
0' x
6' -
2 W
indo
ws
(OPP
106M
)