Test Report Number: ETRA80348
Reference Standard: CFR Title 47, FCC Part 15, Class B; EN 55022: 2006, Class B; EN 55011: 2007, Class B Group 1; ICES-003, Class B
Date of Test: 28 March 2008
Date of Report: 10 April 2008
Product Name: IonCleanse Solo
Model Number: Solo
Serial Number: S01001
Manufacturer: Stargate International, Inc.
Representative: Bob Walker
Report Type: Radiated and Conducted Emissions
Test Result: Compliant
Approved By:
VCCIC-2697 R-2462
BSMISL2-IN-E-1134R
FCC319793 & 610588
MICUS0168
The results contained within this report relate only to the product tested.This report shall not be reproduced, except in full, without written approval from EMC Integrity, Inc.
This report must not be used by the client to claim product certification, approval, or endorsement by EMC Integrity,NEMKO, NVLAP, NIST, or any agency of the federal government.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 2
Prepared for:
Stargate International, Inc. 10235 S Progress Way, # 7
Parker, Colorado 80134 Phone: 303-840-8206 Fax: 303-840-8320
Customer Representative:
Bob Walker CEO
Tested at:
EMC Integrity, Inc. 1736 Vista View Drive
Longmont, Colorado 80504
Tested by:
Don Lighthart EMC Test Technician
Report Prepared by:
Mary Burback
Office Manager
Report Approved by:
Chris Poore Laboratory Manager
Revision Description of Revision Date: Rev. - Initial Release 10 April 2008
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 3
TABLE OF CONTENTS
Section # Test Summary .......................................................................................................1.0 Test Environment..................................................................................................2.0 Radiated Emissions ...............................................................................................3.0 Conducted Emissions............................................................................................4.0 AC Power Line Flicker .........................................................................................5.0
LIST OF APPENDICES Radiated Emissions Test Data ......................................................... APPENDIX A Conducted Emissions Test Data, 120 Vac/60 Hz ........................... APPENDIX B Conducted Emissions Test Data, 230 Vac/50 Hz ........................... APPENDIX C AC Power Line Flicker ..................................................................... APPENDIX D Product Data Sheet ........................................................................... APPENDIX E EMI Test Log......................................................................................APPENDIX F Laboratory Accreditations...............................................................APPENDIX G
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 4
1.0 TEST SUMMARY 1.1 Product Description The unit under test (UUT) was the IonCleanse Solo. The serial number tested was S01001. This product is manufactured by Stargate International, Inc located in Parker, Colorado. It is a detoxifying footbath used to maintain high energy levels, detoxify the body and ensure long-term wellness.. Additional product information may be found in the Product Data Sheet, located in Appendix E of this report. 1.2 Purpose This report documents the test efforts performed on the IonCleanse Solo to verify compliance to the Class B limits of FCC Part 15, EN 55022: 2006, EN 55011 and ICES-003. This was a formal qualification test and was conducted on 28 March 2008. 1.3 Test Standards Used The emission limits applied to the product tested are defined in EN 55022: 2006, which is the product family standard for Information Technology Equipment (ITE). The UUT was set up as specified in ANSI C63.4: 2003. The normative references of this standard define the test methods used for the emissions testing. These standards are contained in Table 1-1.
Table 1-1
CISPR 11: 2004 + A2: 2006 EN 55011: 2007 CISPR 22: 2006 EN 55022: 2006 CFR 47, FCC Part 15 EN 61326: 2002 EN 60601-1-2: 2001 EN 55103-1: 1997 EN 61000-6-3: 2001 EN 61000-6-4: 2001 ANSI C63.4: 2003 CISPR 16-1: 2002 EN 61000-3-2: 2006 EN 61000-3-3: 1995 + A1 (2001) + A2 (2006)
1.4 Test Results The UUT complied with the emission requirements defined by FCC Part 15, EN 55022: 2006, EN 55011: 2007 and ICES-003. The UUT also complied with the AC power line flicker requirements of EN 61000-3-3. Test data is contained in the appropriate appendices of this report. 1.5 Modifications Required for Compliance None.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 5
2.0 TEST ENVIRONMENT 2.1 Radiated Emissions Test Site Radiated emissions testing was performed at a distance of 10-meters in a semi-anechoic 10-meter chamber. This chamber is calibrated annually and meets the volumetric site attenuation requirements of ANSI C63.4: 2003. For measurements from 30 MHz to 2 GHz, a biconilog antenna is used in conjunction with a high-gain, low-noise preamplifier. This is connected to an HP 8566B spectrum analyzer with an HP 85650A Quasi-Peak (QP) Adapter, via an HP 85685 RF Preselector. Radiated emissions testing is broken into two parts: pre-scan and QP/maximization. Pre-scanning a product from 30 MHz to 2 GHz consists of measuring peak emissions from eight radials (every 45 degrees), at four antenna heights (1 m, 2 m, 3 m and 4 m) for both antenna polarities. Data is recorded in a graph showing amplitude vs. frequency of the emissions, and frequencies for QP/maximization are chosen based on this graph. The procedure for maximizing emissions is as follows:
1. The analyzer is tuned to the frequency associated with the emissions having the least margin.
2. The turntable and antenna mast are moved to the location where the maximum emission was measured during the pre-scan.
3. Both are then oriented such that the maximum emission is obtained. 4. Cables on the UUT are manually manipulated to achieve the maximum emission. 5. The turntable and antenna mast are then re-adjusted to ensure a maximum reading. 6. If the signal in question is less than 1 GHz, quasi-peak detection is performed on the
signal for a minimum of 10 seconds. For signals greater than 1 GHz, video averaging is performed.
7. Turntable/antenna mast maximization and QP detection are performed on all other signals within 6 dB of the limit. In the event that there are not six signals within 6 dB of the limit, the highest six signals are maximized. This ensures that a minimum of six signals are maximized and appear in the final data table.
2.2 Conducted Emissions Test Site Conducted emissions testing was performed on a 10’ by 10’ ground plane, which is bonded to the wall of the 10-meter chamber, using its wall as the vertical coupling plane. Line impedance stabilization networks (LISNs) was inserted in series with both the UUT and the support equipment. The LISNs used were standard 50 Ω/50 uH LISNs which complied with the requirements of ANSI C63.4. These LISNs are calibrated annually for both complex impedance and insertion loss. Measurement equipment used was an HP 8566B spectrum analyzer with an HP 85650A QP adapter. In addition, a transient limiter and a high-pass filter are used to protect the front-end of the receiver from transients and low-frequency noise, respectively.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 6
2.3 Measurement Uncertainty The measurement uncertainty for EMC Integrity’s emissions test facility complies with the requirements defined in CISPR 16. The complete calculations of EMC Integrity’s measurement uncertainty is contained in an EMCI memo, which is available upon request. However, a summary of EMCI’s measurement uncertainty is given in Table 2-1.
Table 2-1
Test Requirement Actual Conducted Emissions 3.60 dB 3.04 dB Radiated Emissions – Horizontal Polarity 5.20 dB 4.67 dB Radiated Emissions – Vertical Polarity 5.20 dB 5.01 dB
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 7
3.0 Radiated Emissions 3.1 Summary of Test Results Radiated electric field emissions were measured on the UUT over the frequency range from 30 MHz to 1 GHz. A pre-scan was performed on the UUT at both 120 Vac/60 Hz and 230 Vac/50 Hz to determine worst-case. The formal radiated emissions test was performed using 120 Vac/60 Hz, as that was the worst-case mode. The UUT was configured in its normal operating mode, and exercised continually during testing. Cables were oriented such that the maximum emission was achieved and quasi-peak detection was performed all signals (minimum of six) used in the final data table. Test result: Compliant Margin: 1.82 dB @ 95.566 MHz 3.2 Test Setup The UUT was set up in accordance with ANSI C63.4: 2003 and tested to the Class B limits specified by the applicable standards. 3.3 Special Configurations Not applicable. 3.4 Deviations from Test Procedures Not applicable. 3.5 Test Data See APPENDIX A for all test data sheets, test setup pictures and test equipment used.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 8
4.0 Conducted Emissions 4.1 Summary of Test Results Conducted emissions were measured on the AC power input of the UUT over the frequency range from 150 kHz to 30 MHz. With the UUT configured in its normal operating mode, testing was performed with UUT powered from 120 Vac/60 Hz and 230 Vac/50 Hz. The input power to both the UUT and the support equipment was run through standard 50 Ω/50 uH line impedance stabilization networks (LISNs) which complied with the requirements of ANSI C63.4. Emissions were compared to both quasi-peak (QP) and average limits, with QP detection and averaging performed on the six highest signals. 120 Vac/60 Hz Test result: Compliant Margin: 11.51dB @ 13.158 MHz 230 Vac/50 Hz Test result: Compliant Margin: 14.15 dB @ 6.593 MHz 4.2 Test Setup The UUT was set up in accordance with ANSI C63.4: 2003 and tested to the Class B limits specified by the applicable standards. 4.3 Special Configurations Not applicable. 4.4 Deviations from Test Procedures Not applicable. 4.5 Test Data See APPENDICES B and C for all test data sheets, test setup pictures and test equipment used.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 9
5.0 EN 61000-3-3: 1995 + A1 (2001) + A2 (2006), Power Line Flicker 5.1 Summary of Test Results Power line flicker from the UUT was measured on the system's AC power input with the UUT in normal operating mode. The power source was a 230 Vac/50 Hz source. Integral to the power source was the measurement hardware/firmware and flicker was recorded to the computer. Results are then imported via soft copy to the test data sheet. The UUT complied with the flicker requirements of EN 61000-3-3. 5.2 Test Setup The UUT was set up per EN 61000-3-3. 5.3 Special Configurations N/A 5.4 Performance Criteria Defined in EN 61000-3-3. 5.5 Deviations from Test Procedures N/A 5.6 Test Data See APPENDIX D for data sheets and test setup pictures. 5.7 Temperature and Humidity Temperature, relative humidity and barometric pressure are located in the header table for the EN 61000-3-3 test data sheet.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 10
APPENDIX A
Radiated Emissions Test Data
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 11
Radiated Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003 Date: March 28, 2008 Temperature: 20˚C Humidity: 20% Pressure: 838mb
Input Voltage: 120VAC@60Hz
Configuration of Unit: Normal use
Test Engineer: Donald Lighthart A80348-11-RE.doc FR0100 Type Frequency
(MHz) Level
(dBuV) Transducer
(dB/m) Gain / Loss
(dB) Final
(dBuV/m) Azm(deg)/Pol/Hgt(m) Margin: EN55011 Class B Group
1 QP (dB) QP 95.566 49.5 9.1 -30.4 28.2 119/V-Pole/4.00 1.82 QP 31.201 35.2 20.1 -30.5 24.9 330/V-Pole/1.00 5.13 QP 40.663 34.5 13.3 -30.4 17.4 210/V-Pole/1.00 12.58 QP 81.506 37.8 7.6 -30.7 14.8 144/V-Pole/3.43 15.25 QP 160.553 40.6 12.1 -30.3 22.4 277/V-Pole/2.00 7.58 QP 865.540 29.7 21.6 -28.4 22.8 244/V-Pole/3.96 14.19 The highest emission measured was at 95.566 MHz, which was 1.82 dB below the limit.
“Type” refers to the type of measurement performed. The type of measurement made is based on the requirements of the particular standard:
• PK = Peak Measurement
• QP = Quasi-Peak Measurement
• AV = Video Average Measurement
The “Final” emissions level is attained by taking the “Level” and adding the “Transducer” factor and the “Gain/Loss” factor. Final measurements are made with the Azimuth, Polarity, Height, and EUT Cables positioned for maximum radiation. If applicable, cables positions are noted in the test log.
The “Azm/Pol/Hgt” indicates the turn-table azimuth, the antenna polarity, and the antenna height where the maximum emissions level was measured.
The “Margin” is with reference to the emissions limit. A positive number indicates that the emission measurement is below the limit. A negative number indicates that the emission measurement exceeds the limit.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 12
Radiated Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-RE.doc FR0100
Figure A1: Radiated Emissions Prescan – 30MHz – 1GHz
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 13
Radiated Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-RE.doc FR0100
Figure A2: Radiated Emissions Test Setup - Front
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 14
Radiated Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-RE.doc FR0100
Figure A3: Radiated Emissions Test Setup - Right
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 15
Radiated Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-RE.doc FR0100
Figure A4: Radiated Emissions Test Setup - Back
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 16
Radiated Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-RE.doc FR0100
Figure A5: Radiated Emissions Test Setup - Left
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 17
Radiated Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-RE.doc FR0100
Test Equipment List ID
Number Manufacturer Model # Serial # Description Cal Date Cal Due
1092 Hewlett Packard
8495B 2522A10285 0 - 70 dB Step Attenuator 07/23/2007 07/23/2008
1220 Mini-Circuits ZKL-2 062906 Preamp, 10 - 2000 MHz, 30 dB 02/02/2008 02/02/2009 1229 Hewlett
Packard 85685A 3010A01077 RF Preselector 06/12/2007 06/12/2008
1232 Sunol Sciences JB1 A071605-2 Bilog Antenna, 30 MHz to 2.0 GHz
07/23/2007 07/23/2008
1233 Sunol Sciences SC104V 110305-1 Positioning Controller NA NA 1234 CIR
Enterprises 10m Chamber 001 10m Radiated Emissions Semi-
Anechoic Chamber 05/05/2007 05/05/2008
1238 Sunol Sciences TWR95-4 110305-3 Antenna Mast NA NA 1239 Sunol Sciences FM2522VS 110305-2 Turn Table, 2.5m Diameter NA NA 1263 Hewlett
Packard 8566B 3014A06873 Spectrum Analyzer, 100 Hz to 22
GHz 08/21/2007 08/21/2008
1264 Hewlett Packard
85662A 2848A18247 Spectrum Analyzer Display 08/21/2007 08/21/2008
1265 Hewlett Packard
85650A 2521A00641 Quasi-Peak Adapter 08/21/2007 08/21/2008
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 18
APPENDIX B
Conducted Emissions Test Data 120 Vac/60 Hz
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 19
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003 Date: March 28, 2008 Temperature: 20˚C Humidity: 19% Pressure: 838mb
Input Voltage: 120VAC@60Hz
Configuration of Unit: Normal use
Test Engineer: Donald Lighthart A80348-11-CE.doc FR0100 Type Frequency
(MHz) Level
(dBuV) Transducer
(dB) Gain / Loss
(dB) Final
(dBuV) Test Point Margin: FCC Class
B AV (dB) Margin: FCC
Class B QP (dB) AV 0.208 13.7 3.2 10.1 26.9 Line 1 27.40 - QP 0.207 17.5 3.2 10.1 30.8 Line 1 - 33.52 AV 1.060 16.5 1.3 10.2 28.0 Line 1 17.98 - QP 1.060 20.2 1.3 10.2 31.8 Line 1 - 24.23 AV 4.705 18.2 1.5 10.2 29.9 Line 1 16.10 - QP 4.705 22.1 1.5 10.2 33.8 Line 1 - 22.17 AV 6.715 22.7 1.6 10.2 34.5 Line 1 15.50 - QP 6.715 27.2 1.6 10.2 39.0 Line 1 - 20.96 AV 9.482 24.2 1.5 10.0 35.8 Line 1 14.24 - QP 9.482 27.5 1.5 10.0 39.0 Line 1 - 21.03 AV 13.158 27.4 1.2 9.8 38.5 Line 1 11.51 - QP 13.158 29.7 1.2 9.8 40.8 Line 1 - 19.23 AV 0.950 11.9 1.3 10.2 23.4 Neutral 22.55 - QP 0.950 17.2 1.3 10.2 28.7 Neutral - 27.32 AV 1.060 16.6 1.3 10.2 28.1 Neutral 17.88 - QP 1.060 20.6 1.3 10.2 32.1 Neutral - 23.89 AV 6.445 23.8 1.6 10.2 35.5 Neutral 14.45 - QP 6.445 26.9 1.6 10.2 38.8 Neutral - 21.25 AV 9.567 23.3 1.5 10.0 34.8 Neutral 15.23 - QP 9.567 27.3 1.5 10.0 38.8 Neutral - 21.23 AV 14.488 25.3 1.2 9.8 36.3 Neutral 13.70 - QP 14.488 27.7 1.2 9.8 38.7 Neutral - 21.27 AV 19.275 20.6 1.3 9.9 31.8 Neutral 18.22 - QP 19.275 23.9 1.3 9.9 35.1 Neutral - 24.91 The highest emission measured was at 13.158 MHz, which was 11.51 dB below the limit.
“Type” refers to the type of measurement performed. The type of measurement made is based on the requirements of the particular standard:
• PK = Peak Measurement
• QP = Quasi-Peak Measurement
• AV = Video Average Measurement
The “Final” emissions level is attained by taking the “Level” and adding the “Transducer” factor and the “Gain/Loss” factor.
The “TestPoint” indicates which AC or DC input power line or which I/O cable the measurement was made on.
The “Margin” is with reference to the emissions limit. A positive number indicates that the emission measurement is below the limit. A negative number indicates that the emission measurement exceeds the limit.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 20
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure B1: Conducted Emissions Prescan - Line 1.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 21
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure B2: Conducted Emissions Prescan - Neutral.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 22
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure B3: Conducted Emissions Test Setup - Front
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 23
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure B4: Conducted Emissions Test Setup - Left
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 24
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure B5: Conducted Emissions Test Setup - Right
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 25
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure B6: Conducted Emissions Test Setup - Back
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 26
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Test Equipment List ID
Number Manufacturer Model # Serial # Description Cal Date Cal Due
1195 Solar 9252-50-R-24-BNC
042013 LISN 04/20/2007 04/20/2008
1201 Agilent Technology
11947A 3107A03807 Transient Limiter, 9 kHz to 200 MHz
01/03/2008 01/03/2009
1213 Solar 7930-100 885210 High Pass Filter, fc: 100kHz, -100dB @ 33kHz
04/20/2007 06/20/2008
1229 Hewlett Packard
85685A 3010A01077 RF Preselector 06/12/2007 06/12/2008
1263 Hewlett Packard
8566B 3014A06873 Spectrum Analyzer, 100 Hz to 22 GHz
08/21/2007 08/21/2008
1264 Hewlett Packard
85662A 2848A18247 Spectrum Analyzer Display 08/21/2007 08/21/2008
1265 Hewlett Packard
85650A 2521A00641 Quasi-Peak Adapter 08/21/2007 08/21/2008
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 27
APPENDIX C
Conducted Emissions Test Data 230 Vac/50 Hz
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 28
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003 Date: March 28, 2008 Temperature: 20˚C Humidity: 19% Pressure: 838mb
Input Voltage: 230VAC@50Hz
Configuration of Unit: Normal use
Test Engineer: Donald Lighthart A80348-11-CE.doc FR0100 Type Frequency
(MHz) Level
(dBuV) Transducer
(dB) Gain / Loss
(dB) Final
(dBuV) Test Point Margin: EN55011
Class B Group 1 & 2 AV (dB)
Margin: EN55011 Class B Group 1 &
2 QP (dB) AV 0.206 23.0 3.2 10.1 36.3 Line 1 18.06 - QP 0.206 24.3 3.2 10.1 37.6 Line 1 - 26.78 AV 0.756 16.8 1.5 10.2 28.5 Line 1 17.51 - QP 0.756 18.9 1.5 10.2 30.5 Line 1 - 25.45 AV 1.060 18.9 1.3 10.2 30.4 Line 1 15.63 - QP 1.060 23.1 1.3 10.2 34.6 Line 1 - 21.39 AV 6.695 23.9 1.6 10.2 35.7 Line 1 14.35 - QP 6.695 25.0 1.6 10.2 36.8 Line 1 - 23.18 AV 8.913 23.1 1.6 10.1 34.9 Line 1 15.15 - QP 8.913 25.8 1.6 10.1 37.5 Line 1 - 22.54 AV 12.518 24.6 1.3 9.8 35.7 Line 1 14.33 - QP 12.518 27.5 1.3 9.8 38.6 Line 1 - 21.39 AV 0.208 17.9 3.2 10.1 31.2 Neutral 23.10 - QP 0.208 20.4 3.2 10.1 33.7 Neutral - 30.65 AV 1.060 18.4 1.3 10.2 30.0 Neutral 16.03 - QP 1.060 21.9 1.3 10.2 33.4 Neutral - 22.57 AV 4.512 13.9 1.5 10.2 25.6 Neutral 20.40 - QP 4.512 18.4 1.5 10.2 30.1 Neutral - 25.85 AV 6.593 24.1 1.6 10.2 35.9 Neutral 14.15 - QP 6.593 26.9 1.6 10.2 38.7 Neutral - 21.31 AV 9.652 22.7 1.5 10.0 34.1 Neutral 15.86 - QP 9.652 26.1 1.5 10.0 37.5 Neutral - 22.48 AV 19.318 17.3 1.3 9.9 28.5 Neutral 21.47 - QP 19.318 19.6 1.3 9.9 30.8 Neutral - 29.16 The highest emission measured was at 6.593 MHz, which was 14.15 dB below the limit.
“Type” refers to the type of measurement performed. The type of measurement made is based on the requirements of the particular standard:
• PK = Peak Measurement
• QP = Quasi-Peak Measurement
• AV = Video Average Measurement
The “Final” emissions level is attained by taking the “Level” and adding the “Transducer” factor and the “Gain/Loss” factor.
The “TestPoint” indicates which AC or DC input power line or which I/O cable the measurement was made on.
The “Margin” is with reference to the emissions limit. A positive number indicates that the emission measurement is below the limit. A negative number indicates that the emission measurement exceeds the limit.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 29
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure C1: Conducted Emissions Prescan - Line 1.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 30
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure C2: Conducted Emissions Prescan - Neutral.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 31
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure C3: Conducted Emissions Test Setup - Front
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 32
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure C4: Conducted Emissions Test Setup - Left
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 33
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure C5: Conducted Emissions Test Setup - Right
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 34
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Figure C6: Conducted Emissions Test Setup - Back
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 35
Conducted Emissions, CISPR / EN 55011 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: 10m Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / ICES-003
Date: March 28, 2008 A80348-11-CE.doc FR0100
Test Equipment List ID
Number Manufacturer Model # Serial # Description Cal Date Cal Due
1195 Solar 9252-50-R-24-BNC
042013 LISN 04/20/2007 04/20/2008
1201 Agilent Technology
11947A 3107A03807 Transient Limiter, 9 kHz to 200 MHz
01/03/2008 01/03/2009
1213 Solar 7930-100 885210 High Pass Filter, fc: 100kHz, -100dB @ 33kHz
04/20/2007 06/20/2008
1229 Hewlett Packard
85685A 3010A01077 RF Preselector 06/12/2007 06/12/2008
1263 Hewlett Packard
8566B 3014A06873 Spectrum Analyzer, 100 Hz to 22 GHz
08/21/2007 08/21/2008
1264 Hewlett Packard
85662A 2848A18247 Spectrum Analyzer Display 08/21/2007 08/21/2008
1265 Hewlett Packard
85650A 2521A00641 Quasi-Peak Adapter 08/21/2007 08/21/2008
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 36
APPENDIX D
AC Power Line Flicker Test Data
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 37
AC Power-Line Flicker per IEC / EN 61000-3-3 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: GP #2 Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN 61000-6-2 Date: April 2, 2008 Temperature: 21˚C Humidity: 32% Pressure: 836mb
Input Voltage: 230Vac/50Hz
Configuration of Unit: Running positive mode at 70% and Negative mode at 30%
Test Engineer: Tom Wittig A80348-3-3.doc FR0100
Flicker Test Summary per EN/IEC61000-3-3 (Run time)
EUT: IonCleanse Solo Tested by: Tom Wittig Test category: All parameters (European limits) Test Margin: 100 Test date: 4/2/2008 Start time: 2:02:52 PM End time: 4:02:55 PM Test duration (min): 120 Data file name: F-000080.cts_data Comment: A80348 Customer: Stargate International Test Result: Pass Status: Test Completed Psti and limit line European Limits
0.25
0.50
0.75
1.00
Pst
14:13:1014:23:0914:33:0714:43:0614:53:0415:03:0315:13:0115:23:0015:32:5815:42:5715:52:5516:02:54
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 38
Plt and limit line
0.20.30.40.50.6
P
lt
16:02:54
Parameter values recorded during the test: Vrms at the end of test (Volt): 230.14 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.160 Test limit: 0.650 Pass
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 39
AC Power-Line Flicker per IEC / EN 61000-3-3 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: GP #2 Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN 61000-6-2
Date: April 2, 2008 A80348-3-3.doc FR0100
Figure D1. AC Power Line Flicker Test Setup.
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 40
AC Power-Line Flicker per IEC / EN 61000-3-3 Manufacturer: Stargate International Project Number: A80348
Customer Representative: Bob Walker Test Area: GP #2 Model: IonCleanse Solo S/N: S01001
Standard Referenced: EN 61000-6-2
Date: April 2, 2008 A80348-3-3.doc FR0100
Test Equipment List ID
Number Manufacturer Model # Serial # Description Cal Date Cal Due
1026 California Instruments
5001iX 55638 AC Power Source, 5kVA NA NA
1153 California Instruments
PACS-1 72229 Harmonics and Flicker Measuring Network
01/04/2008 01/04/2009
1185 California Instruments
CTS 3.0 NA CTS V3.0.15, Application program for Harmonics and
NA NA
1207 Extech 445715 252867 Hygro-Thermometer 03/24/2008 03/24/2009
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 41
APPENDIX E
Product Data Sheet
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 42
1.0 Client Information Client Information Manufacturer Name Stargate International, Inc. Address 10235 S Progress Way, # 7 City Parker State Colorado Zip Code 80134 Client Representative Bob Walker-Administration /Brian Bell-Engineering Title CEO/Engineer Phone 303-840-8206 Fax 303-840-8320 Email [email protected] [email protected]
2.0 Product Information - General
Product Information Product Name (as it should appear on test report) IonCleanse Solo Model Number Solo Functional description of product
The IonCleanse Solo is a detoxifying footbath used to maintain high energy levels, detoxify the body and ensure long-term wellness.
Product type (IT, Medical, Scientific, Industrial, etc.) Household/Scientific Is the product an intentional radiator No Product Dimensions 6”W x 2 7/8” H x 7 7/8” L Product Weight 1.5 Lbs. Will fork lift be required No Applicable Standards, if known EN 55011 / EN 55022 / FCC Part 15 / ICES-003, EN
61000-6-1: 2007 Describe all environment(s) where product will be used
Office Environment (alternative medicine practitioners, practitioners, etc.), Household
Does product consist of multiple components? (If yes, please describe each system component)
Yes – 1. Power Supply, 2. Control box, 3. Array
Cycle time > 3 seconds? (If yes, How long?) Product constantly updates. Max run time of 45 minutes
Highest internally generated frequency 4 MHz Xtal to 1 Microprocessor Product Set-up Time <5minutes Boot up time in the event of an unintentional power down
<1 minute
Identify all I/O Connections as well as maximum associated cable lengths below Model No. Description Shielded? Length Quantity
Array Foot bath Array Assembly NO 6ft 1 MPU50-107 Power supply Switching NO 6ft 1
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 43
3.0 Power Power Requirements Input Voltage Rating as it appears on unit, power supply, or power brick
PS 100-240 VAC 47-63hz Output is 20 VDC @ 2.5 amps
Input Current (specify @ 230 Vac/50 Hz) 1.35 A Single or Multi-Phase (If multi-phase, specify delta or wye)
Single phase
Is input power connector two-prong (Hot & Neutral) or 3-prong (H, N, Ground)
3 prong
Does UUT have more than 1 power cord? (If yes, explain.)
no
4.0 Unit Under Test (UUT) – Detailed Information UUT Hardware Condition Production Configuration During Test Normal Operation (70% pos / 30% neg)
Input Power 100 – 240 Vac UUT Components
Name Model No. Serial No. Description
P/S MPU50-107 N/A
AC to DC external Power Supply Manufacturer: SinPro Input Rating: 100 – 240 Vac, 47-63 Hz, 1.35 A Output Rating: 16-21 Vdc, 50 W
Control Box
IonCleanse Solo 01001 Footbath controller
Input ratings: 20 Vdc, 2.5 A Array N/A N/A Footbath array for insertion into footbath
I/O Cabling See Section 2.0 for details UUT Software/Firmware
Name Version/Revision Functionality
IonCleanse Solo 7A05
IonCleanse Solo firmware for normal operation. Maximum run time of 45 minutes
70% pos / 30% neg
UUT Operating Conditions List all frequencies the product generates/uses 4 MHz
How will product be exercised during test? Normal Use (70% pos / 30% neg) How will product be monitored during test? Visually
What are the product’s critical parameters? No unexpected change in display readings Specify tolerance of all critical parameters. No unexpected change in display readings
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 44
5.0 Support Equipment (SE) – Detailed Information Support Equipment (SE)
Name Model No. Serial No. Description N/A N/A N/A N/A
SE I/O Cabling Model No. Description Shielded? Length Quantity
N/A N/A N/A N/A N/A
SE Software/Firmware Name Version/Revision Functionality N/A N/A N/A
6.0 Block Diagram
(Must be completed prior to testing).
AC to DC Converter AC
IonCleanse Solo
Array
DC
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 45
APPENDIX F
EMI Test Log
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 46
EMI Test Log Manufacturer: Stargate International Project Number: A80348
Model: IonCleanse Solo S/N: S01001 Customer Representative: Bob Walker
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / IECS-003
FR0105
Test Test Code
Date Event Time (hrs)
Result Initials
RE 1151 March 28, 2008 1700
Test# 1, 30MHz – 1GHz, 8 radials, 4 heights, 3 sec. Dwell, 80dB Ref. Level 230VAC@50Hz
1.0 --- DL
1151 1800 Test# 2, 30MHz – 1GHz, 8 radials, 4 heights, 3 sec. Dwell, 80dB Ref. Level 120VAC@60Hz – Determined to be worst case voltage
1.0 Pass DL
CE 2151 1900 Test# 3, 150kHz – 30MHz, 3 sec. Dwell, 80dB Ref. Level 230VAC@50Hz
0.5 Pass DL
CE 2341 1930 Test# 4, 150kHz – 30MHz, 3 sec. Dwell, 80dB Ref. Level 120VAC@60Hz
0.5 Pass DL
4-3 4344 0800 Radiated RF Immunity 3V/m, 80 - 1000 MHz, 1% Step, 80% AM, 1kHz sine, 3s dwell 230 VAC / 50 Hz
3.5 Pass TW
4-3 4390 1130 Radiated RF Immunity (Medical Requirement) Perform testing from 1.0 GHz - 2.0 GHz 3V/m. If product passes, it fulfills generic requirements 230 VAC / 50 Hz
1.0 Pass TW
4-3 4391 1230 Radiated RF Immunity Radiated RF Immunity 1V/m, 2.0 - 2.7 GHz, 1% Step, 80% AM, 1kHz sine, 3s dwell 230 VAC / 50 Hz
1.0 Pass TW
4-3 4391 --- Radiated RF Immunity Radiated RF Immunity 3V/m,1.4 - 2.0 GHz, 1% Step, 80% AM, 1kHz sine, 3s dwell 230 VAC / 50 Hz
0.0 Pass TW
1400 Completed RF Immunity 6.0 --- TW 4-4 4401 1400 Electrical Fast Transient / Burst
Mains: +/- 1kV, I/O: +/- 500V 230 VAC / 50 Hz
1.0 Pass TW
4-4 4410 1500 Electrical Fast Transient / Burst (medical requirement) Mains: +/- 2kV, I/O: +/- 500V 120 VAC / 60 Hz
1.0 Pass TW
4-4 4411 Electrical Fast Transient / Burst (medical requirement) Mains: +/- 2kV, I/O: +/- 500V 230 VAC / 50 Hz
0.5 Pass TW
4-5 4515 April 2, 2008 Surge Immunity Mains: +/- 2kV CM, +/- 1kV DM, (0, 90, 180, 270) 230 VAC / 50 Hz
5.0 Pass TW
3-3 3302 AC Short and Long Term Flicker -- 230 VAC / 50 Hz
2.0 Pass TW
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 47
EMI Test Log Manufacturer: Stargate International Project Number: A80348
Model: IonCleanse Solo S/N: S01001 Customer Representative: Bob Walker
Standard Referenced: EN55011 / EN55022 / FCC Part 15 / IECS-003
FR0105
Test Test Code
Date Event Time (hrs)
Result Initials
4-11 4141 April 3, 2008 0800
Voltage Dips and Interruptions (Medical Requirement) 0% nom, 0.5 cycles / 40% nom, 5 cycles / 70% nom, 25 cycles / 0% nom, 250 cycles 230 VAC / 50 Hz
1.0 Pass TW
4-11 4140 0900 Voltage Dips and Interruptions (Medical Requirement) 0% nom, 0.5 cycles / 40% nom, 5 cycles / 70% nom, 25 cycles / 0% nom, 250 cycles 120 VAC / 60 Hz
0.5 Pass TW
4-11 4191 0930 Voltage Dips and Interruptions Voltage Dips and Interrupts 0% nom,1.5 cycles/70% nom, 25 cycles @ 50 Hz/70% nom, 30 cycles @ 60 Hz 230 VAC / 50 Hz
1.0 Pass TW
4-11 4190 1030 Voltage Dips and Interruptions Voltage Dips and Interruptions 0% nom, 250 cycles @ 50 Hz / 0% nom, 300 cycles @ 60 Hz 230 VAC / 50 Hz
0.5 Pass TW
4-5 4535 1100 Setup and ran Surge Immunity (Medical Requirement) Mains: +/- 2kV CM, +/- 1kV DM, (0, 90, 270) 120 VAC / 60 Hz
4.0 Pass TW
4-6 4612 1500 Setup and ran Conducted RF Immunity 3Vrms, 0.15 - 80 MHz, 1% Step, 80% AM, 1kHz sine, 3s dwell 230 VAC / 50 Hz AC Power tested
1.0 Pass TW
4-6 4611 April 4, 2008 0800-0900
Conducted RF Immunity (Medical Requirement) 3Vrms, 0.15 - 80 MHz, 1% Step, 80% AM, 1kHz sine, 3s dwell (test array cable) 230 VAC / 50 Hz
1.0 Pass TW
4-2 4223 0900-1100 Electrostatic Discharge +/- 2, 4kV Contact, +/-2, 4, 8kV Air 230 VAC / 50 Hz
2.0 Pass TW
4-2 4290 1100-1130 Electrostatic Discharge (Medical Requirement) +/-6 kV Contact-This is the required level for Medical. Perform after official test and note results 230 VAC / 50 Hz At +6kV, contact discharge to the left side screen causes unit to reboot At -6kV, contact discharges causes the display to be scrambled Could not repeat consistently.
0.5 --- TW
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 48
APPENDIX G
Laboratory Accreditations
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 49
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 50
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 51
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 52
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 53
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 54
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 55
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 56
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 57
EMC INTEGRITY, INC. Test Report # ETRA80348
Rev. - Total Pages: 58 58
END OF REPORT