Test Instrumentation & Automated Test Systems

Power Conversion Hipot / Safety Component Automated Systems

www.conres.com/test-equipment

Page 2: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

PV Inverter ATS

Telecom ATS

HEV Controller / DC-DC ATS

Chroma’s engineering team delivers cost-effective architecture and software platforms designed to fit our customer’s diverse power conversion and electrical safety test technical requirements by maximizing their time, improving validation processes, and increasing output.

Our engineering capabilities provide for the design, development and delivery of turnkey automated test systems and fixtures for many power conversion and electrical safety test applications. We also provide modification and updating of existing test systems.

Our area of expertise is power conversion test and characterization delivering automated solutions to many industries.

Power Conversion• Switching Power Supply

• PC Power Supply

• Telecom Power Supply

Battery• Programmable Charge/Discharge

• Regenerative Battery Pack

• Secondary Battery Module and Pack

EV / EVSE• EV Charging

• DC–DC Converter

• HEV Controller / DC-DC

• Motor Driver

LED / Lighting• LED Power Driver

• High Speed LED Bulb or Tube In-line

• LCD Inverter / Ballast

Military / Aerospace• Repair Depot

• Government Contract / Tier-1 Support

• Design Verification Test

Solar• On-Grid PV Inverter

• Off-Grid PV Inverter

• Solar Panel

Regenerative Burn-in• AC - AC Power Supply

• DC - DC Converter

• LED Driver

Medical / Safety• Medical Device – IEC60601-1, IEC

60601-2-49 (Multifunctional Patient Monitoring Equipment)

• Electrical Equipment Safety and Functional Test

Automated Test Systems

Automated Systems

2

Page 3: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

Regenerative Battery Pack ATS 17030

Programmable Charge/Discharge ATS 17020

DC - DC Converter ATS

EV Charger ATS

Switching Power Supply ATS

Test Fixtures• Engineering Characterization & Design

Validation

• Custom Test Fixtures & Test Programs

• High Volume Production

• A/B & Parallel Testing for High Volume Applications

• Vendor Qualication & Incoming Inspection

• Depot Repair & Failure Analysis

Global Support• Global Operations & Worldwide Support

• Depot Repair & Failure Analysis

• Local & International Program Management

Hardware• Widest Selection of High Precision Test

Instrumentation

• Highly Customizable Congurations & UUT Interfaces

• Extensive Communication Support: CAN, LAN/ Ethernet, I2C, PMbus, USB, GPIB, Serial, etc.

• Individual Instrumentation Display Panels & Controls Simplies Debugging

• Supports Complex Inter-Instrument Triggering

• Optimized for High Throughput Testing

• Dynamically Congurable for R&D Engineering & Design Validation

Software• Enterprise Wide Open Architecture

Platform

• Custom Reporting with Waveforms & Graphs for R&D & Design Validation

• Fast & Easy, Excel Like Test Sequence Development

• Customer Editable Test Library Without Coding

• Statistical Reporting

• Command Optimizer Maximizes Test Speed

• A/B & Parallel Testing for High Volume Applications

8000 Automated Test Platform

3

Page 4: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

LineSimulation

Current (+)

1

V

4

Voltage (-)

Sink 2 Source 1

Voltage (+)

3 2

1

I

2

Source 3 Sink 4

3 4

Output Curr. Reverse Curr. Current (-)

AC Power Sources

Power Rating: up to 90kVA, single or three phase output

Output Voltage: 0-150V / 0-300V

Key Features• Programmable transients for Mil-Std-704, DO-160 and IEC standards

• Built-in Harmonics, inter-harmonics and waveform generator

• Wide range of models starting at 500VA

• Labview graphical user interface including Aerospace standards

• GPIB, RS232, USB and Ethernet

All Programmable AC Power Sources

Standard Low Power Standard High Power Advanced Low Power Advanced High Power Grid Simulator

Model 61600 61611, 61612 61500 61511, 61512 61800

Power Rating 500VA - 4000VA 12kVA / 18kVA 500VA - 4000VA 12kVA / 18kVA 30kVA / 45kVA / 60kVA

Voltage Range 0-150V/0-300V/Auto 0-150V/0-300V/Auto 0-150V/0-300V/Auto 0-150V/0-300V/Auto 0-330VLN / 0-571VLL

Frequency DC, 15Hz-1kHz DC, 15Hz-1.5kHz DC, 15Hz-1kHz DC, 15Hz-1.5kHz DC, 30Hz-100Hz

Remote Interface GPIB, RS-232C GPIB, RS-232, USB, Ethernet GPIB, RS-232C (opt) GPIB, RS-232, USB, Ethernet GPIB, RS-232, USB, Ethernet

LIST, PULSE, STEP modes

Programmable voltage and current limit

Programmable slew rate setting

Harmonic synthesizer (up to 50)

Turn on/o phase angle control

Comprehensive measurements, including current harmonics

Analog programmable interfaces Optional

Optional Graphic User Interface

LineSimulation

The 61500 series denes a new standard in high performance AC power sources. It's equipped with powerful features such as power line disturbance simulation, programmable output impedance, comprehensive measurement functions and optional regulation test software.

List Mode:voltage transientprogramming

Power rating: up to 300kVA, single or three phase output

Output voltage: 0-330V L-N / 0-571V L-L (0-400V L-N / 0-692V L-L opt.)

Key Features• Improved front panel display with real time waveform viewer

• Maximum power delivered down to 200VAC L-N

• Achieves 400V L-N / 692V L-L without using a transformer

• Parallel modular design allows for eld expansion up to 300kVA

• Harmonics, inter-harmonics waveform synthesizer

Regenerative Grid Simulator

Programmable AC Source

Distorted Waveform Editor

Grid Simulator 61860

Max Power Delivered Down to 200VAC L-N

Full Four-quadrant, Fully Regenerative Design

AC Power Source 61512

Designed for PV inverter, Smart Grid and EV test applications, the 61800 Regenerative Grid Simulator is a full 4 quadrant, fully regenerative, programmable AC power source with advanced features for compliance, safety and product verication testing. Power can both sink and source from the UUT seamlessly to support a multitude of applications. In cases where the UUT sources current, a detection circuit will sense the excess power and recycle it back to the grid. Using state-of-the-art digital control technology the 61800 can deliver up to 330VAC at output frequencies ranging from 30Hz to 100Hz. The AC+DC feature allows for applications that require a DC oset bias.

4

Voltage (V)

CHROMA

Competitor

12000

8000

14000

16000

200 300100

Pow

er (W

)

Page 5: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

DC Power Supplies

Power ranges: 2kW / 5kW / 10kW / 15kW - up to 150kW

Operating range: 1000V / 375A

Key Features• Master/Slave, parallel and series operation to 150kW with current

sharing

• High speed transient generator for solar, automotive and aerospace applications

• Voltage & Current Slew Rate Control

• Labview graphical user interface

• GPIB, RS232, USB and Ethernet

Programmable DC Power Supply 62150H-40

Static and Dynamic MPPT eciency test

Programmable DC Power

Solar Array Simulation

All Programmable DC Power Supplies

62000H-S models have a built in SAS mode that program Voc, Isc, Vmp and Imp parameters to simulate dierent solar cell materials I-V characteristic outputs with fast response time required for PV Inverter design as well as verication testing.

Constant Power DC Supply Modular - Hot Swappable Programmable High Power Solar Array Simulation (SAS)

Model 62000P 62000B 62000H 62000H-S

Power Rating 600W, 1200W, 2400W, 5000W up to 1.5kW per module - up to 120KW per system 5kW / 10kW / 15kW 2kW / 5kW / 10kW / 15kW

Voltage Range 0 - 600V 1 - 150V 0 - 1000V 0 - 150V/600V & 1000V

Current Range up to 2000A (System) 0 - 375A

High-speed Programming

Precision V&I Measurements

Current sharing for parallel operation with Master/Slave Control

Ideal for Burn-in & Electrolysis

Voltage & Current Slew Rate Control

Standard Analog Programming interface

Fast transient response solar array simulation

Static & dynamic MPPT eciency test

Optional Graphic User Interface

Chroma’s 62000H programmable DC Power Supplies oer many unique advantages for telecom, automated test system and integration, industrial, battery charge & simulation for hybrid cars and solar panel simulation. These advantages include a high power density of 15KW in 3U, precision read back of output current and voltage and output trigger signals as well as the ability to create complex DC transient waveforms to test device behavior to spikes, drops and other voltage deviations.

5

Page 6: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

Modular Electronic DC Load

Programmable AC/DC Load

All Electronic Loads

The new generation 63600 DC Electronic Loads provide an innovative Dynamic Sweep mode with Vpk measurements that can be run independently on each module or in parallel for high power loading. Also allows for three measurement ranges for precise voltage and current measurements making it ideal for ENERGY STAR® testing requirements. The 63600 also provides an enhanced feature, User Defined Waveform (UDW), to simulate the actual current profiles and waveforms.

Chroma’s 63800 AC/DC load simulates load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing resulting in reliable and unbiased test results. The 63800 uses DSP technology to simulate non-linear rectified loads with its unique RLC operation mode. This mode improves stability by detecting the impedance of the UUT and dynamically adjusting the load’s control bandwidth to ensure system stability. Designed for testing UPS’s, off-grid inverters, AC sources and other power devices.

Programmable AC/DC Load NEW High Power DC Load Standard DC Load Advanced DC Load

Model 63800 63200A 6310A Modular 63600 Modular

Power Rating 1800W / 3600W / 4500W 4kW, 5kW, 6kW, 20kW, 24kW 100W, 200W, 250W, 300W, 600W 100W, 300W, 400W

Voltage Range 50V – 350Vrms 0-150V / 0-600V / 0-1200V 0 - 500V 0 - 600V

Current Range up to 45Arms up to 2000A up to 240A up to 80A per module

Dynamic Loading 45-440Hz 50kHz 20kHz 50kHz

Remote Interface RS-232, GPIB USB, GPIB, Ethernet USB, GPIB, RS-232 USB, GPIB, Ethernet

Max Channels per Mainframe 1 1 8 10

Master/Slave Parallel Control

Synchronize with Multiple Loads

Load Modes CC, CR, CP CC, CR, CV, CP, CZ CC, CR, CV, CP CC, CR, CV, CP, CZ

Programmable Slew Rate

LED Array Simulation

Constant Impedance Mode

V & I Digitizer

Analog Input

Optional Graphic User Interface

Loaded 5 bay mainframe 63600 (2 bay and single bay mainframes available)

AC electronic load 63802

Electronic Loads

Power Range: up to 2KW, 10 channels (High Power loads: Up to 75KW)

Operating Range: up to 1000VDC

Key Features• Voltage and current waveform digitizer on each channel

• Unique constant CZ allows for non-linear load simulations

• Current down to zero voltage, full current to 0.4VDC

• High speed transient generator and user defined waveforms

• Labview graphical user interface

• GPIB, RS232, USB and Ethernet

Power Rating: up to 67.5KVA - 3Ph

Peak Current: up to 135A

Key Features• High Crest Factor Range: 1.414 to 5.0

• CC, CR, CV, CP for DC loading

• Parallel units for higher power and three phase operation

• GPIB and RS-232 interfaces

6

Page 7: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

Single and Multi-Channel Power Meters

All Power Meters Multimeters

Chroma’s multi-channel Power Meters make accurate power measurements for various wiring modes including three phase WYE and DELTA and split phase. These power meters feature state-of-the-art DSP digitizing technology which replaces less accurate and slower traditional analog circuits. The internal 16 bit analog/digital converters with sampling rates of up to 250 kHz provide both high speed and high accuracy measurements. The meters are designed to comply with power measurement requirements in accordance to many international standards such as ENERGY STAR®, EN 50564, IEC 62301 and ErP.

Single Channel Multi-Channel

Model 66201 / 66202 66203 / 66204

Voltage Range 150 / 300 / 500 Vrms 15 / 30 / 60 / 150 / 300 / 600 1200 (optional) Vrms

Current Range 0.01 / 0.1 / 0.2 / 0.4 / 2 / 8 / 20 Arms

0.005 / 0.02 / 0.05 / 0.2 / 0.5 / 2 / 5 / 20 Arms

Frequency Range DC, 15Hz-10kHz DC, 15Hz-10kHz

Minimum Current Range / Power Resolution 10mA / 0.1mW 5mA / 0.1mW

Measurement Channels 1 3 / 4

Meets ENERGY STAR® / IEC 62301 / EN 50564 / ErP

Embedded high speed DSP, 16 bits Analog / Digital converters

Dual current shunt design provides high accuracy over a wide current range

66202 only

THD and user-specify order distortion measurement 66202 only

Inrush current and energy measurements 66202 only

Voltage / Current harmonics measurements up to 50 orders

Supports various single and 3 phase wiring congurations

Optional Graphic User Interface

Digital Multimeter

Model 12061

Resolution 6 ½ Digits

Measurement Characteristics

DC voltage/current (1000V/3A max)

AC voltage/current (750V/3A max)

Resistance, 2 or 4 wire ohms measurement, Period & frequency, Diode & continuity, Temperature

(Thermocouple & RTD)

Math FunctionsNULL Max / Min / Avg High / Low limit Percentage / Ratio / MX+B

dB / dBm

DC Voltage Accuracy 0.0015%

AC Voltage Accuracy 0.04%

Remote Interface USB (standard), GPIB (option)

Memory Storage 2000 readings

Optional Multi-point TC Scanner Card (10ch), multi-point scanner card (10/20ch)

Measurement and data transmission up to 2000 readings/sec (4½)

Standard SCPI control

Optional Graphic User Interface

4 channel power meter 66204

Main screen

Current harmonic measurement table

Power Meters& Multi Meters

Power Range: up to 600Vrms (1200Vrms opt.)

Operating Range: up to 20Arms p/ch (100Arms w/ opt. external shunt)

Key Features• Embedded high speed DSP, 16 bits Analog/Digital converters

• Supports dierent wiring congurations for power measurement (1P2W/1P3W/3P3W/3P4W)

• Dual current shunt design provides high accuracy over a wide current range

• 5 mA minimum current range and 0.1mW power resolution

• Accumulated energy methods for unstable power measurements

• THD and user-specied order distortion measurements

• Inrush current and energy measurements

• Voltage and Current harmonics measurement up to 50 orders

• Labview graphical user interface

• GPIB, RS232, USB and Ethernet

7

Page 8: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

Common Applications

• Power Supplies, Adapter and Chargers

• Home Appliance (IEC 60335)

• Information Technology Products (IEC 60950)

• Medical Devices (IEC 60601)

• Video Products (IEC 60065)

• Lab/Testing Equipment

• Electric Vehicle Safety

• LED/Lighting (IEC61347-1)

The 19032 performs six dielectric tests in one unit including AC/DC Hipot, Insulation Resistance, Ground Bond, Leakage Current and Dynamic Function tests for compliance testing of IEC, UL, TUV, CSA, EN and other standards. The time-saving TwinPort™ feature performs Hipot and Ground Bond simultaneously cutting time for these tests in half. The 19032 also has an open / short check function (OSC) that checks for an open connection or a DUT short during testing. The analyzer’s leakage current scanners can provide up to 20A input current capability for functional run testing as well as earth, patient and line leakage current tests. The analyzer is equipped with programmable limits for pass/fail testing as well as storage and recall of 50 dierent test setups with 100 steps per setup.

Electrical Safety Analyzer

Electrical Safety Analyzer Hipot Analyzer 500VA High Voltage Hipot Analyzer

Model Guardian19032 / 19032-P 500VA Guardian 19055, 19055-C Guardian 19056, 19057

Mode (Model Specic) AC / DC / IR / GB / LC / Dynamic Function AC / DC / IR AC or DC / IR

Channels 1 (up to 64 opt) 1, 8 (opt) 1

Hipot Test: Output Voltage AC: 0.05 - 5kVDC: 0.05 - 6kV

AC: 0.05 - 5kVDC: 0.05 - 6kV

19056: AC 0.1 - 10kV19057: DC 0.1 - 20kV

Hipot Test: Cuto CurrentAC: 100mADC: 25mA

19056: AC 20mA19057: DC 10mA

Insulation Resistance Test 0.1MΩ ~ 50GΩ / 1kV max 1MΩ ~ 50GΩ / 5kV max 0.1MΩ ~ 50GΩ / 5kV max

Ground Bond Test 10mΩ ~ 510mΩ / up to 40A

Leakage / Patient Leakage Test with A190308 Leakage Scanner

Programmable Outputs and Limits

Remote Interface RS-232 (std) GPIB (opt) RS-232 , Handler (std), GPIB (opt) RS-232, Handler, USB, Scan (std), GPIB (opt)

OSC (Open / Short Check)

Flashover Detection

GFI (Ground Fault Interrupt)

Contact Check Function OSC HFCC HVCC, HFCC

Corona Discharge Detection 19055-C

Cerication UL/TUV/CE CE CE

All Safety and Hipot Analyzers

Hipot safety analyzer 19032

Safety and HipotAnalyzers

Automate testing by using our CaptivATE software with a Guardian 19032 Safety Analyzer. Test functions include: AC/DC Hipot, insulation resistance, ground bond, earth leakage, patient leakage, patient auxiliary leakage, or enclosure current leakage, as well as a functional check. Provides tests for IEC 60601/60950/61010/60335 requirements. Testing is made simple and fast by automatically downloading the test setup, conducting the required measurements and outputting the test results.

Hipot Output Voltage: AC 0.05 - 5kV, DC 0.05 - 6kV

Insulation Resistance Test: 0.1MΩ ~ 50GΩ / 1kV Max

Key Features• Six tests in one unit: AC / DC / IR / GB / LC / Dynamic Function

• Optional patient leakage test

• UL / TUV / CE

8

Page 9: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

• 10 channels per unit - up to 100 channels total

• Master/Slave link

All Hipot Testers

chromausa.com/instruments/hipotsafety

The Guardian 19020 comes equipped with the world’s rst sync hipot test function. A single unit can perform 10 channels sync output and measurements simultaneously. Ten units in master & slave conguration can be controlled simultaneously for 100 channels in total. They also can be grouped for output to avoid creating voltage dierences due to adjacent tests as well as to improve productivity.

The 19572 is an instrument dedicated to measuring grounding resistance within a range of 0.1~510mΩ. Its compact size and easy operation makes it perfect for testing in a production line. Since it supplies highly reliable and stable test results with a built-in resistance compensation function, the 19572 is an economical and useful ground bond tester.

Multi-Channel Hipot Tester

Standard Hipot Tester Advanced Hipot Tester Multichannel Hipot Tester

Model Sentry 19070 Guardian 19050 Guardian 19020

Mode (Model Specic) AC or AC / DC / IRAC / DC / IR or

AC / DC / IR / SCANAC or AC / DC / IR

Channels 1 1, 8 (opt) 10 (up to 100)

Hipot Test: Output VoltageAC: 0.05 - 5kVDC: 0.05 - 6kV

AC: 0.05 - 5kVDC: 0.05 - 6kV

AC: 0.05kV - 6kVDC: 0.05kV - 8kV

(models vary)

Hipot Test: Cuto CurrentAC: 20mADC: 5mA

AC: 30mADC: 10mA

AC: 10mADC: 5mA

Insulation Resistance Test 1MΩ - 50GΩ / 1kV max (19073 only) 1MΩ - 50GΩ / 1kV max 1MΩ - 50GΩ / 1kV max

Remote Interface RS-485 (opt) RS-232 (std), GPIB (opt) RS-232, Handler (std), GPIB (opt) *CANBUS & DCI used for Max. 10 units master/slave connections

Master/Slave link

Programmable output and limits

OSC (Open/Short Check)

Flashover Detection

GFI (Ground Fault Interrupt)

Ground Continuity Check

Fast charge/discharge function

Certication CE, UL, TUV CE, UL, TUV (most models) CE

Ground Bond Tester

Model 19572

High Current Ground Continuity up to 45Amps

Resistance Measurements 0.1 - 510mΩ

Digital Readout Current, Resistance, Test Time

Communication Interface RS-232 (std) GPIB (opt)

Certication CE, TUV

Programmable high and low resistance limits

Adjustable test time

Built-in calibration via software

Automatic oset of lead resistance

Built-in resistance compensation

Ground Bond Tester - 45Amp

Multi-channel hipot tester 19020

Hipot Testers& Ground Bond

9

Page 10: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

chromausa.com/instruments/meters

• Test Parameters: L/C/R/Z/Y/DCR/Q/D/ θ

• Set test frequencies in 1Hz increments

• Test Level: 10mV ~ 5V

• Basic Accuracy: 0.1%

5 or 10MHz LCR Meter with Detached Design

In addition to the excellent measurement features shared with other Chroma LCR Meters, the 11050 has 3 output impedance modes to meet the demands of measuring and working with other instruments. The exible digital display allows adjustment to best t the test resolution, while the test signal monitoring function is able to display the voltage and current actually being applied to the DUT. The timing settings for trigger delay, measure delay, and average number of times allow the measurements to work closely with automated machines to get the most accurate results with limited testing time. The detached design of the Chroma 11050 uses a dual CPU system for processing the testing and display individually. This not only increases testing speed but also shortens test lead lengths when used with automated machines to improve the accuracy of high frequency measurements.

5 / 10MHz LCR Meter 10 / 50 kHz LCR Meter 100kHz LCR Meter Capacitor Leakage Current/IR Meter

Model 11050 / 11050-5M 11021 / 11021-L 11022 / 11025 11200

Test Parameters L, C, R, Z, Y, DCR, Q, D, øPrimary: L, C, R, | Z |

Secondary: Q, D, ESR, Xs, ø

L, C, R, | Z |, Q, D, ESR, X, ø DCR4, M, Turns Ratio, L2, DCR2

(11025 only)LC / IR

Test Frequency 1kHz ~ 10MHz (11050)60Hz ~ 5MHz (11050-5M)

100Hz, 120Hz, 1kHz, 10kHz (9.6kHz)(11021)

1kHz, 10kHz, 40kHz, 50kHz(11021-L)

50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz,

100kHz

Test Levels 10mV - 5V0.25V / 1V (11021)

50mV / 1V (11021-L)10 mV - 1V , step 10 mV 1.0 - 100V, step 0.1V: 101 - 650V or

800V, step 1V

Basic Accuracy 0.1%0.1% (11021)

0.2% (11021-L)0.1% 0.3%

Measurement Time 15mS - 295mS 75mS 21mS 77mS - 420mS

Output Impedance Modes 100Ω, 25Ω, OFF Varies as range resistors 25Ω, 100Ω, 1kΩ, 10kΩ, 100kΩ 2Ω, 10Ω, 25Ω, 100Ω Varies as range resistors

Adjustable DC Bias Current 11025 only

Test Signal Monitoring Function

Output Signal Compare, Bin-sorting Bin-sorting & HI/GO/LOW judge Bin-sorting & HI/GO/LOW judge HI/GO/LOW judge

Open/short zeroing & load correction function Open Correction

Detached measurement & display unit design

Lower Harmonic-distortion aection

Remote InterfaceRS-232C, Handler, USB storage,

Ext bias current control (std)GPIB, LAN (opt)

RS-232 (std)Handler & GPIB (opt)

Handler (50pin), GPIB, RS-232RS-232 (std)

Handler & GPIB (opt)

Digital Milliohm Meter

Model 16502

Test Modes DC Mode, Pulse Mode, Dry Circuit

Measurement Range0.001mΩ - 1.9999MΩ

with 4 1/2 digits resolution

Basic Accuracy 0.05%

Measurement Time 65ms - 650ms

Communication Interface RS-232 (std), Handler & GPIB (opt)

Milliohm Meter

• Basic accuracy : 0.05%

• Pulsed test current output mode to reduce the eect of thermal EMF on milliohm measurement

• DC test current output mode to increase measurement speed for inductive DUT

• Dry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mV

• Temperature correction (TC function) regardless of material or temperature

10MHz LCR meter 11050

All LCR Meters

LCR, IR, and Milliohm Meters

10

Page 11: Test Instrumentation & Automated Test Systemsinfo.conres.com/acton/attachment/2004/f-07c7/1/-/-/-/-/Brochure_CS… · PV Inverter ATS Telecom ATS. HEV Controller / DC-DC ATS. Chroma’s

Wound Component Testers

Dataloggers and TEC Controllerschromausa.com/instruments/thermoelectric

TEC Controller

Model 54100

TEC Output Voltage 24, 27, or 40VDC

TEC Output Current 8, 12, or 20A

TEC Driving Output Power 150, 300, or 800W

Controller Temperature Setting Range -49 to 149° or -70 to 20°

Controller Setting Resolution 0.01°

Temperature Control Stability Short Term: ≤0.01°, Long Term: ≤0.05°

Monitoring Temperature Range -49 to 149° or -70 to 20°

Temperature Sensor Type T-type (Std), K-type (Opt 54180)

Monitoring Temp Resolution 0.01°

Monitoring Temp Relative Accuracy ≤0.03°

Monitoring Temp Absolute Accuracy < ±(0.3+0.002×|T-25|)°

Data Logger

Model 51101

Thermocouple/Temperature Accuracy ±(0.01% of reading +0.3) ˚C

Thermocouple Jacks/Connectors B, E, J, K, N, R, S, or T mini-type

Number of Inputs (Model Dependent) 1, 8, 16, 24, 32, 40, 48, 56, 64 channel

Temperature Sensor Type Thermocouple: B, E, J, K, N, R, S, T

Temperature Scale ITS-90

Temperature Resolution ±0.01˚C

CJC Error ±0.3˚C

Maximum Sample Rate 5 sample/sec.

Channel to Channel Isolation 1000VDC / 750 Vrms

Input Resistance 5MΩ

Thermocouple break detection current 100 nA

64 channel

8 channel

1 channel

NEWMotor Stator Test System

Wound Component Testers

ThermoelectricTesters

11

Wound Component Scanner Wound Component Analyzer

Model Hybrid 19035 19036

Mode (Model Specific) AC / DC / IR / DCR -8CH AC / DC / IR / Impulse (surge) / DCR

Channels 8 10 (up to 40 opt.)

Hipot Test: Output Voltage AC: 0.05 - 5kVDC: 0.05 - 6kV

AC: 0.05 - 5kVDC: 0.05 - 6kV

Insulation Resistance Test 1MΩ ~ 50GΩ / 5kV Max 0.1MΩ ~ 50GΩ / 5kV Max

DCR Measurement 4-wire DCR measurement 4-wire DCR measurement, Δ / Y motor winding calculation

Remote Interface RS-232 (std) GPIB (opt), Handler (opt) RS-232, Handler, USB, LAN

OSC (Open / Short Check)

Flashover Detection

GFI (Ground Fault Interrupt)

Flashover Detection

CE mark

Impulse Winding Test

7 Tests in One System:

ACW / DCW / IR / IWT / DCR / L / Q / Phase

The 1920 Motor Stator Test System integrates our 19036 Wound Component Analyzer equipped with AC&DC Hipot testing, insulation resistance measurement, 4-terminal DC resistance measurement, and impulse winding test capabilities with 10 ports scanner; 3252 LCR Meter for Ls/Q and winding phase measurement; vacuum system and test fixture. It also provides standard software for system control and tested data collection.