terratek integrity monitoring of structures

Upload: oniel888

Post on 03-Apr-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 Terratek Integrity Monitoring of Structures

    1/5

    Terratek carries out dynamic loading tests on structures usingadvanced vibration analysis techniques and state-of-the art

    elec tronics. The tests are totally non-destructive and non-

    intrusive.

    The equipment used to take measurements is a very sensitive 24-bit vibration recorder. It is so accurate that is able to measuredisplacements o the order of magnitude of the wavelength oflight. Therefore there os no need to induce artificial vibrations, aswe measure the response due to ambient loading like wind,traffic, waves or temperature.

    This technology has been successfully applied to many structures,

    including bridges, steel tower, tall buildings, dams, harbour and

    offshore structures.

    Dynamic monitoring of structures

    Dynamic load testing of structures

    Terratek

    Av rico Verssimo 901 / 30222621-180 Rio de J aneiro, RJ,

    Braziltel 21 2486 3386Contact Dr Beto [email protected]

    In Brasil:

    Rio de janeiro

    Belo Horizonte,

    Overseas:

    Caracas, Venezuela

    Lima, Peru

    Kuala Lum ur, Malsia

    Small sized vibration recorder

    Standard

    Measurements and analyses follow the following Standard:

    ABNT NBR 15307 Non-destructive testing Dynamic loading

    testing on large structures Procedure

    The scope of the Pias system is to analyse structural integrity, by

    chec king stresses and strains in the whole structural system,

    detecting:

    o Global structural integrity

    o Location and extend of damage;

    o Structural behaviour under additional loading;

    o Degradation, aging and structural life span.

    24-bit Vibration recorder

    Scope of measurements

    Visit our website: www.terratek.com.br

  • 7/29/2019 Terratek Integrity Monitoring of Structures

    2/5

    2

    PAG 2

    Projects

    Terratek has successfully tested the following range of structures:

    Mosquito RailwayBridge

    Harbour structures, TubaroHarbour

    Conveyor beltand ship loader

    Dynamicloading testof jetty anddolphinstructure

    Bridge integrityassessment

    Safety check of the

    roof of football stadium

    200 m high TVtower, Braslia

    Offshorestructures

    Bridge integrity assessment, BR101 motorway, Brazil

    Damage detection on aconcrete dam

  • 7/29/2019 Terratek Integrity Monitoring of Structures

    3/5

    3

    PAG 3

    Damage detection on Arealdam

    Pias

    Amplitude %

    0 5 10 15 20 25

    Damping

    (x10-3)

    0

    1

    2

    3

    4

    5

    6

    MR

    0 1 2 3 4

    -9

    -8

    -7

    -6

    -5

    -4

    Frequenc y (Hz)

    PSD Amplitude (g2/Hz x 10-6)

    Spectrum Damping

    Vibration spectrum and damping

    Vibration measurements with time on a structure enable to obtain spectra and damping,by proper mathematical analyses. These data are the bac kbone for understandingstructural behaviour and the effect of damage and aging.

    Miningstructures:crushers, Millsand scrubberbuilding

  • 7/29/2019 Terratek Integrity Monitoring of Structures

    4/5

    4

    PAG 4

    Mathematical modelling

    The next step is to build a dynamic mathematical model of the structure through astructural dynamics software. Initially the model outputs the undamaged behaviour.Then, structural damage is simulated on a trial and error process until the structure outputsresonance frequencies that match with the measurements. At this stage the model iscalibrated and its behaviour matches the actual structure. Then, the mathematicalmodel can be used to check the behaviour under an type of loading.

    Curitiba

    So Paulo

    P1

    P2

    P3

    P4P5

    P6

    P7

    P8

    Y

    Conveyor belt showingdynamic instability on a slender

    column

    Damage detection on highwaybridge

    Transverse instability duringtrain passage, MosquitoBridge

  • 7/29/2019 Terratek Integrity Monitoring of Structures

    5/5

    5

    PAG 5

    Damage level

    Dynamic loading tests give the overall damage level of a structure. This information will beused by decision makers and the structural designer to decide on the extend of

    rehabilitation works.

    Votorantim MiningRPM Kinross Mining

    Highway Dept BrazilCVRD Vale do Rio Doce Mining CompanySeebla Consulting Engineering, So PauloRPeotta Harbour Engineering, Rio de J aneiroTecnosonda SA, Rio de J aneiroSonda Engineering Ltd, BrasliaNovacap Braslia

    On-line real time vibration measurements

    Terratek carries out continous on-line structural monitoring. This enables a continuouscheck on damage level and structural aging. In this case, vibration monitors are fixedon selected structural members on the structure and linked to the internet. Acomputer program analyses vibration data, yielding spectra, velocities, displacementsand damping.

    Clients