Page 1: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

TENANT DESIGN MANUAL

UPDATED JUNE 2016

Page 2: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

PROJECT OVERVIEW

2

The Shops at Chestnut Hills is located is located along State Route 9 (Boylston Street) and Hammond Pond Parkway in the

heart of Chestnut Hills. It is two miles south of the Massachusetts Turnpike and three miles east of I-95.

Page 3: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

PROJECT OVERVIEW

3

The Shops at Chestnut Hill is home to the only Bloomingdale’s location in New England. It offers exclusive luxury boutiques as

well as stores such as Armani Collezioni, Maximillian Furs, Giorgio Armani and Jimmy Choo.

Page 4: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

TENANT INFORMATION PACKAGE

COMPONENT DESCRIPTION

TIP Index Will provide a comprehensive list of topics to help

locate information

Tenant Design

Manual

Provide mall specific architectural, sign and

engineering design criteria

Kiosk Design Manual

Architectural Criteria Outline submission requirements and will provide

necessary guidelines to design your store.

MEP/FP Criteria (same as Architectural Criteria)

Bulletins

4

• The Tenant Information Package (TIP) is intended to provide you with the

project’s design and construction criteria and consists of several parts:

Page 5: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

5

TENANT INFORMATION PACKAGE

• The Tenant Information Package can be accessed from Simon’s website – simon.com.

» Select the business header, search for the property name, click on the Tenant Info Package link on

the right side of the page.

» If you have any difficulties working with the website, please contact your Tenant Coordinator.

*For questions regarding the Landlord’s design and construction requirements, please

contact your Tenant Coordinator or call 317-636-1600 and ask for Tenant Coordination.

Page 6: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

Occupancy/ Use: Mercantile

Construction Classification: Type IIA

Building Levels: Two (2) Level

Sprinkler System: Fully Sprinkled

*Site Plan and Leasing Plan available for Tenant’s to use on Simon.com. Select the

business header, search for the property name, click on links on right side of page.

MALL BUILDING DATA

6

Page 7: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

STOREFRONT ZONE PLAN-LEVEL 1

7

All 1st floor Tenant’s to build to 12’0” to

underside of bulkhead. Tenant’s storefront sign

to project up a minimum of 3’ and maximum of

4’ above the 12’ height. Do not impede existing

diffusers on the underside of bulkhead.

Page 8: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

STOREFRONT ZONE PLAN-LEVEL 2

8

All 2nd floor Tenants to increase storefront

above bulkhead area by 4’ bringing storefront

height to 16’. Diffusers to be incorporated to the

new storefront height.

Tenant storefront is 12’-0” to

underside of mall soffit.

Page 9: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

STOREFRONT ELEVATION-LEVEL 1

9

Neutral Pier

Maximum storefront

height throughout mall

is 12’ – 0” A.F.F.

Mall Bulkhead

Sign projection above

12’-0” high storefront

Page 10: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

STOREFRONT ELEVATION-LEVEL 2

10

Neutral Pier

Mall Bulkhead

4’-0” additional

storefront to total

height to 16’-0”

Page 11: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

NEUTRAL PIER DETAIL

11

Wall Base Detail

6” 6”

12”

Page 12: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

EXTERIOR FACADES

12

Tenant sign type and

location is subject to

approval of Landlord’s

Tenant Coordinator

Façade is not to be

altered by Tenant

Page 13: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

STOREFRONT SIGNS, AWNINGS & CANOPIES

13

Page 14: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

HVAC – RETAIL TENANTS

14

This is an enclosed rooftop unit mall. Engineer is required to accommodate conditions that may

affect the performance of the HVAC system for their store.

• Equipment Air conditioning and heating equipment must be adequate to maintain within the premises at Landlord set conditions. All Tenant’s equipment must be a minimum of 15’ 0” away from any intake duct. Tenants may not cut through existing roof.

• Condensate Drain Condensate to be piped from rooftop unit through curb to approved sanitary connection within space.

• Outside/Relief Air Economizer and barometric or fan powered relief through Tenant installed components.

• Return Plenum (Ducted return is for odor producing Tenants only and subject to Landlord approval).

• Exhaust/Relief. Operators must provide adequate exhaust system to comply with Mall and local heath regulations

• Toilet Exhaust Tenant to install ceiling exhaust fan with back draft damper, and connect to outlet in Landlord’s central toilet exhaust system.

• Odor, Thermal & Process Equipment Exhaust Operators must provide adequate exhaust system to comply with Mall and local heath regulations. The location and installation of the system shall be coordinated with the Tenant Coordinator and Mall Operations Manager.

• Temperature Controls Stand-alone digital electric/electronic control system by Tenant.

• Test & Balance Tenant shall employ a TAB, NEBB or AABC Certified Air Balance Contractor to perform final testing and balancing.

• See Criteria Sheet MEP-1 for further information.

Page 15: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

• Water Redistributed by Landlord via overhead mains. Minimum 1” valved connection. Tenant supplied meter w/remote reader

for large water users only. In portions of the mall, Tenants are a direct customer of the Utility. Refer to the Utility Redistribution

Plan within this criteria for applicable location.

• Waste 4” wye connection off Landlord main. Designated connection point within or adjacent to space.

• Vent Utilize existing connection or Tenant to install new.

• Grease Waste No Landlord provisions.

• Natural Gas Available to food service Tenants ONLY. All work by Tenant including meter if not existing.

• Toilet Rooms As required by code.

• Drinking Fountain Per code and ADA requirements.

• Service Sink As required by code.

• See Criteria Sheet MEP-1 for further information.

PLUMBING – RETAIL TENANTS

15

Page 16: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

• Implementation Tenant shall directly employ the Landlord designated contractor to install and/or modify existing grid or utilize

connection provided.

• Tenant Flow Switch Not permitted.

• Valve for Tenant Space Not permitted.

• See Criteria Sheet MEP-1 for further information.

FIRE PROTECTION- RETAIL TENANTS

16

Page 17: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

• Voltage 277/480, 3ph, 4-wire

• Landlord Equipment Exterior cable busway with meters and fusible switches or interior metering boards. Minimum 2” empty conduit.

• Power Provided by Landlord redistribution system. Tenant to provide disconnect, fusing, meter and conductors and connect to Landlord distribution board (if not existing).

• Metering Reuse existing or provide new per Landlord specification.

• Capacity TENANT MAXIMUM ALLOTMENT IS 20 WATTS PER SQUARE FOOT. Submit connected and demand electrical load data to support electric service size requested.

• Telephone The Tenant must consult directly with the telephone company and arrange for individual service from the project service locations to the tenant demised space.

• Fire Alarm Interface with Landlord system is only permitted when the Tenant occupancy requires a system to meet Code. If required by Code, Tenant to provide required panel and devices compatible with Simplex 4100 system. Duct detectors to shut down RTU equipment to be annunciated within Tenant space only.

• See Criteria Sheet MEP-1 for further information.

ELECTRICAL – RETAIL TENANTS

17

Page 18: TENANT DESIGN MANUAL - Simon Property Group - Tenant Manual.pdfTENANT DESIGN MANUAL UPDATED JUNE 2016 . PROJECT OVERVIEW 2 The Shops at Chestnut Hills is located is located along State

MEP CALCULATION FORMS

18

Tenant’s Engineer shall use their own form

for HVAC Load Calculations:

•Appliance Heat Gain

•Electrical Load Summary

•Kitchen Exhaust Fan Specifications

•Kitchen Make-up Air Unit Specification

•RTU/Split System Specification

•Maintenance