U Length mm Maximum Velocity (meters per second)
U length mm Maximum Velocity (meters per second)
100 45 100 45 150 24 150 24 200 14 200 14 300 6 300 6 400 36 400 3
SAI Global 9001:2008 LIC 14412
TEMPERATURE ºCONTROLS PTY LTD ACN: 650 190 183 ABN: 966 501 901 83
7 YAMMA STREET SEFTON, NSW 2162 AUSTRALIA
PH: (02) 9721 8644 FAX: (02) 9738 9339 EMAIL: [email protected] www.temperature.com.au
Qual
ity S
yste
m
QualityEndorsedCompany
REF: #1519/ #1373
MAXIMUM OPERATING PRESSURES (Process Connection)
Barstock – Screwed Thermowells as per drawing SD 036
316 Stainless steel BSPT/ NPT Male Process
connection
Note: the smaller the process connection the higher the pressure.
BSPT/ NPT Male Process connection KPa bar
1/16" 75,000 760
1/8" 68,000 690
1/4" 55,000 550
3/8" 53,000 540
1/2" 53,000 530 3/4" 50,000 500 1" 36,000 370
1.1/4" 41,000 410 1.1/2" 34,000 340
Calculations based on ASME B31.3 code for Process Piping.
1.00
.90
.70
.80
.60
.40
.50
.30
.20
.10
037 93 148 204 260 315 371 426 482 537 593 648 704 760 815 871
TEMPERATURE DERATING FACTOR
TEM
PE
RA
TUR
E D
ER
ATI
NG
FA
CTO
R
OPERATING TEMPERATURE ºC
Pressure rating procedure 1. For applications at elevated temperatures, the pressure rating must be multiplied by an appropriate temperature derating factor obtained from the temperature derating chart above. 2.. These working pressures are not necessarily valid for system components. Prudent system design requires that all other system components be evaluated for their specific proper pressure capabilities.
Report Information
Customer: Temperature Controls Date / Time:
Tag Numbers: SAMPLE - LIQUID Reference #:
Process Fluids: Liquid Phase
Pipe Size / Schedule: 16" STD
Max Temperature (T) / Pressure (P): 184.1 °C / 1000 KPa
Fluid Flow Rate: 100676.051 in^3/s
Fluid Velocity (v): 14 m/s
Fluid Density: 7.12 Kg/m^3
Fluid Viscosity: 0.0171 centipoise
Density (Pm): 0.29 lb/in^3
Elastic Modulus, E(T): 26400000 psi
Allowable Stress (S) / Fatigue Limit (Sf): 11700 psi/5400 psi
In-Line Reson. Velocity(VIR): 17.97 m/s Von Mises Stress (Root): 59.73 psi
Bending Stress at VIR (So.max) 14787.93 psi
Dynamic Stress at V (So.max) 108.04 psi
Thermowell Configuration Frequency Limit: 0.40 Reynolds # (Re): 110881
Threaded Frequency must be below: 143.78 [Hz] Strouhal # (Ns): 0.1889
Tapered Installed Natural Freq (fnc): 359.45 [Hz] Scruton # (Nsc): 4.91
316/316L Strouhal Frequency (fs): 139.22 [Hz] Freq Ratio (fs/fnc): 0.39
1" NPT
1/2" NPT
316/316L Allowable Stem Pressure(Pc): 4859.96psi
6.5mm Allowable Tip Pressure(Pt): 76666.47psi
250mm
200mm
0mm Status
0mm PASS
22mm PASS
19mm PASS
6mm PASS
0mm
LIC 14412
15/11/2012 1:07:15 PM
WATER AT 93°C
Process Operating Conditions
Stem Style:
Thermowell Material Properties
Stresses
Vibration
Process Connection:
Thermowell Material:
Process Thread:
PressureInternal Thread:
Flange Material:
Bore Size:
Overall Length (L):
Thermowell RatingUnsupported Length (U):
Shielded Length (Lo):
Oscillating Stress (psi) 108.04Lag Extension:
Value
145.03Tip Diameter (B):
Fillet (Root):
Frequency (Hz) 139.21Tip Thickness (t):
Steady-State Stress (psi) 213.538Root Diameter (Q):
Pressure (psi)
SAI Global
ISO 9001
The thermowell design has PASSED the wake frequency calculation“These well design calculations are based on the ASME power test code PTC 19.3- formulas. The results of these calculations
should only be used as a guide for thermowell design. Temperature Controls does not guarantee the performance of a specific
well design obtained from the use of these calculations”.
Printed using the V-MAC Wake Calc System
Report Information
Customer: Temperature Controls Date / Time:
Tag Numbers: SAMPLE - GAS Reference #:
Process Fluids: Gas
Pipe Size / Schedule: 16" STD
Max Temperature (T) / Pressure (P): 184.1 °C / 1000 KPa
Fluid Flow Rate: 100676.051 in^3/s
Fluid Velocity (v): 14 m/s
Fluid Density: 7.12 Kg/m^3
Fluid Viscosity: 0.0171 centipoise
Density (Pm): 0.29 lb/in^3
Elastic Modulus, E(T): 26400000 psi
Allowable Stress (S) / Fatigue Limit (Sf): 11700 psi/5400 psi
In-Line Reson. Velocity(VIR): 17.97 m/s Von Mises Stress (Root): 59.73 psi
Bending Stress at VIR (So.max) 14787.93 psi
Dynamic Stress at V (So.max) 108.04 psi
Thermowell Configuration Frequency Limit: 0.40 Reynolds # (Re): 110881
Threaded Frequency must be below: 143.78 [Hz] Strouhal # (Ns): 0.1889
Tapered Installed Natural Freq (fnc): 359.45 [Hz] Scruton # (Nsc): 4.91
316/316L Strouhal Frequency (fs): 139.22 [Hz] Freq Ratio (fs/fnc): 0.39
1" NPT
1/2" NPT
316/316L Allowable Stem Pressure(Pc): 4859.96psi
6.5mm Allowable Tip Pressure(Pt): 76666.47psi
250mm
200mm
0mm Status
0mm PASS
22mm PASS
19mm PASS
6mm PASS
0mm
LIC 14412
15/11/2012 12:58:54 PM
STEAMED AT 184.1 °C
Process Operating Conditions
Stem Style:
Thermowell Material Properties
Stresses
Vibration
Process Connection:
Thermowell Material:
Process Thread:
PressureInternal Thread:
Flange Material:
Bore Size:
Overall Length (L):
Thermowell RatingUnsupported Length (U):
Shielded Length (Lo):
Oscillating Stress (psi) 108.04Lag Extension:
Value
145.03Tip Diameter (B):
Fillet (Root):
Frequency (Hz) 139.21Tip Thickness (t):
Steady-State Stress (psi) 213.538Root Diameter (Q):
Pressure (psi)
SAI Global
ISO 9001
The thermowell design has PASSED the wake frequency calculation“These well design calculations are based on the ASME power test code PTC 19.3- formulas. The results of these calculations
should only be used as a guide for thermowell design. Temperature Controls does not guarantee the performance of a specific
well design obtained from the use of these calculations”.
Printed using the V-MAC Wake Calc System