telephone entry system - doorking

58
UL Listed Copyright 2009 DoorKing, Inc. All rights reserved. Copyright 2019 DoorKing ® , Inc. All rights reserved. Installation/Owner’s Manual 1803 / 1808 / 1810 1803 / 1808 / 1810 1803 / 1808 / 1810 Use this manual for circuit board 1862-010 Revision O or higher. Control a main entry point plus an additional entry point. Telephone Entry System Date Installed: Installer/Company Name: Phone Number: Leave Manual with Owner Circuit Board Serial Number and Revision Letter: Model Number 1810 1810 1810 1803 1803 1803 1808 1808 1808 1803-084 1803-080 1810-084 1810-080 1808-084 1808-082 Flush Mount Surface Mount Flush Mount Surface Mount Surface Mount Surface Mount with Directory 7 7 8 8 9 9 4 4 5 5 6 6 1 1 2 2 3 3 0 0 Push Button Push Button To Call To Call 7 7 8 8 9 9 4 4 5 5 6 6 1 1 2 2 3 3 0 0 NAME Adams J Bernard E Brown L Davis T Hodges S Miller J Smith K Thomas W Zimmer R 1 9 5 2 4 6 8 3 7 CODE NAME Adams J Bernard E Brown L Davis T Hodges S Miller J Smith K Thomas W Zimmer R 1 9 5 2 4 6 8 3 7 CODE 7 7 8 8 9 9 4 4 5 5 6 6 1 1 2 2 3 3 0 0 7 7 8 8 9 9 4 4 5 5 6 6 1 1 2 2 3 3 0 0 TELEPHONE ENTRY SYSTEM OPERATING INSTRUCTIONS Locate Code Number on Directory. Press Code Number. If Line is Busy, Press “#” to Hang UP. Try Again. Enter on Tone. 1. 2. 3. 7 7 8 8 9 9 4 4 5 5 6 6 1 1 2 2 3 3 0 0 TELEPHONE ENTRY SYSTEM MODEL 1803 OPERATING INSTRUCTIONS Locate Code Number on Directory. Press Code Number. If Line is Busy, Press “#” to Hang UP. Try Again. Enter on Tone. 1. 2. 3. 7 7 8 8 9 9 4 4 5 5 6 6 1 1 2 2 3 3 0 0 Conforms To UL STD 294 Certified To CAN/ULC-S319-05 1800-060 Issued 7-19 Version B

Upload: others

Post on 27-Oct-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Telephone Entry System - Doorking

UL Listed

Copyright 2009 DoorKing, Inc. All rights reserved.

Copyright 2019 DoorKing®, Inc. All rights reserved.

Installation/Owner’s Manual 1803 / 1808 / 18101803 / 1808 / 18101803 / 1808 / 1810

Use this manual for circuit board 1862-010 Revision O or higher.

Control a main entry point plus an additional entry point.

Telephone Entry System

Date Installed:

Installer/Company Name:

Phone Number:

Leave Manual with Owner

Circuit BoardSerial Numberand Revision Letter:

Model Number

181018101810

180318031803

180818081808

1803-0841803-080

1810-0841810-080

1808-084

1808-082

Flush Mount

Surface Mount

Flush Mount

Surface Mount

Surface Mount

Surface Mount

with Directory

7788

99

4455

66

1122

33

00

Push Button

Push ButtonTo CallTo Call

7788

99

4455

66

1122

33

00

NAMEAdams JBernard EBrown LDavis THodges SMiller JSmith KThomas WZimmer R

195246837

CODE

NAMEAdams JBernard EBrown LDavis THodges SMiller JSmith KThomas WZimmer R

195246837

CODE

7788

99

4455

66

1122

33

0012

3

NAME

Bejar IBerlin JBernard EBillings LBroker TBrose SBrown JBrown KBryant WByron RByan G

656078221321249476003112292822491324231332117

Carney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill PDillon MDixon DDominick PDonick PDonner KDonter F

211670441

ar Irlin Jrnard Ellings Lroker TBrose SBrown JBrown KBryant WByron RByan G

656078221321249476003112292822491324231332117

Carney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill PDillon MDixon DDominick PDonick PDonner KDonter F

211670441

7788

99

4455

66

1122

33

0012. Press Code Number. If Line Is Busy, Press Any Button

3. Enter On “OPEN” Display or Tone.

Annese JAnderson HApplegate BAustin DBalsbaugh BBass JBejar IBerlin JBernard EBillings LBroker TBrose SBrown JBrown KBryant WByron RByan G

009115352551656078221321249476003112292822491324231332117

CODENAMEByers MCardillo PCarney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill P

Dillon MDixon DDominick PDonick PDonner KDonter F

807503501404461249772633481104322068888518358467

CODE

NAMEDorland TDownward L

211543987352

Washington GWashington KWent LWhiting MWinston FWyatt J

213229007134609389679211670441

ess Code Number. If Line Is Busy, Press Any Button

nter On “OPEN” Display or Tone.e Json Hgate Bn Dbaugh Bs Jar Irlin Jrnard Ellings Lroker TBrose SBrown JBrown KBryant WByron RByan G

009115352551656078221321249476003112292822491324231332117

CODENAMEByers MCardillo PCarney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill P

Dillon MDixon DDominick PDonick PDonner KDonter F

807503501404461249772633481104322068888518358467

CODE

NAMEDorland TDownward L

211543987352

Washington GWashington KWent LWhiting MWinston FWyatt J

213229007134609389679211670441

TELEPHONE ENTRY SYSTEM

OPERATING INSTRUCTIONS

Locate Code Number on Directory.

Press Code Number. If Line is Busy,

Press “#” to Hang UP. Try Again.

Enter on Tone.

1.2.

3.

7788

99

4455

66

1122

33

00

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONS

Locate Code Number on Directory.

Press Code Number. If Line is Busy,

Press “#” to Hang UP. Try Again.

Enter on Tone.

1.2.

3.

7788

99

4455

66

1122

33

00

Conforms To UL STD 294

Certified To CAN/ULC-S319-05

1800-060 Issued 7-19

Version B

Page 2: Telephone Entry System - Doorking

2 1800-060 Issued 7-19Version B

RING

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

KEYPAD

3 2 1

3 2 1

3 2 1

NOHSTONE

OFF

TONEON

HF

NC C

Phone Line Connection Ring

16AC16ACBAT NC NOCSPKR COMMICGPSWCGNDPHONE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Main Terminal

16 VAC Input Power

20 VA Minim

um16 VAC Input Pow

er

Standby Battery POSITIVE (12 VDC, .7 Ah, SLA) (connect negative to terminal 8)

Relay 1 Normally Open – 30 Volt, 3 Am

p max.

Relay 1 Normally Closed – 30 Volt, 3 Am

p max.

Speaker Output (Purple Wire).

Relay 1 Comm

on

Comm

on for Switch Input 1 term

inal #4, speaker, Standby Battery NEGATIVE

Microphone ground Input (W

hite Wire).

MICM

icrophone Input (Green Wire).

Switch Input 1. A closure betw

een terminals 4 and 8 w

ill cause Relay 1 to activate for theprogram

med strike tim

e or dial a preprogramm

ed phone number – see section 3.1.7.

Postal Switch connection.

Earth Ground Only (See Section 2.1.3). NOT a low voltage com

mon.

Phone Line Connection Tip

Switch Input 2Terminal Non-Removable

Relay 2 TerminalNon-Removable

100 ft. max. w

ith 18 AWG w

ire.200 ft. m

ax. with 16 AW

G wire.

Install ferrite filter on these wires - see section 2.1.5.

Located in the upper left corner of circuit board.

NO NC C

Norm

ally

Ope

n –

30 V

olt,

3 Am

p m

ax.

No

rmal

ly C

lose

d –

30 V

olt,

3 Am

p m

ax.

C

omm

on –

30

Volt,

3 A

mp

max

.

A closure between these terminals will cause Relay 2 to activate for the programmed strike time or dial a preprogrammed phone number (see section 3.1.7).

21

800 ft. max. w

ith 24 AWG w

ire.1600 ft. m

ax. with 22 AW

G wire.

(Wiring M

UST be twisted and isolated from

the ground)

FerriteFilter

QUICK GUIDE: Terminal Descriptions

See page 21 for terminal wiring.

Do Not Connect Power To A Receptacle

Controlled By A Switch.

UL 294TamperSwitchLocated undermicrophone board(See Section 1.7).

Quick Guide - 1

Page 3: Telephone Entry System - Doorking

31800-060 Issued 7-19Version B

Quick Guide - 2

Section 3.3 Entry Code Programming

3.3.13.3.23.3.33.3.43.3.53.3.63.3.73.3.83.3.9

383838383939393939

* 02

* 14

* 00

* 12

* 19

* 09

* 10

* 11

* 13

9999

9999

Programming Four-Digit Entry CodeDelete Individual Four-Digit Entry CodeDelete ALL Four-Digit Entry Codes CAUTIONFour-Digit Entry Code Divide Number to Activate RelaysFour-Digit Entry Code (Reverse Relay Activation ONLY)Programming Five-Digit Entry CodeDelete Individual Five-Digit Entry CodeDelete ALL Five-Digit Entry Codes CAUTIONFive-Digit Entry Code Divide Number to Activate Relays

Page # Factory Setting

Overview for System Programming

Section Command

NO Factory setting0 (single)

Relay 1= 01 (1 sec)Relay 2= 01 (1 sec)

1 (tone ON)060 (60 sec)

Relay 1= 9 8 7 6Relay 2= 5 4 3 20 (relays activate)

02 (two rings)

0 (hang-up)0 (all numbers)

1-relays hang-up1 (hang-up after

5 sec of dial-tone)

Master CodeSingle or Multiple SystemsRelay Strike Time

“Tone Open” Sound ON or OFFTalk TimeTone Open Numbers

Programming Switch Input 1 and Switch Input 2Number of Rings Before Telephone Entry System will AnswerPBX Line Access Code ProgrammingStar Key (*) FunctionKeypad Function (DTMF Programming)System to Stay On-Line or Hang-Up after Touch-Tone Number PressedAutomatic Hang-Up Function

Section 3.1 General Programming

3.1.13.1.23.1.3

3.1.43.1.53.1.6

3.1.73.1.83.1.93.1.103.1.113.1.123.1.13

262828

282829

29293030303031

* 04

* 03

* 17

* 08

* 05

* 23

* 18

* 21

* 27

* 26

* 28

* 40

MasterSwitch ON

Programming Time ClockAutomatic Relay Activation Time ZonesFour-Digit Entry Codes Time ZoneFive-Digit Entry Codes Time Zone“Flash Entry Codes” Active for ONE-DAY ONLY

Section 3.4 Time Functions Programming

3.4.13.4.23.4.33.4.43.4.5

4040414242

* 33

* 35

* 36

* 37

* 15

Section 3.2 Directory Code and Phone Number Programming

3 (3 digits)0 (0 sec)

0 (No)1 (Yes)

32323333343434353536363737

3.2.13.2.23.2.33.2.43.2.53.2.63.2.73.2.83.2.93.2.103.2.113.2.123.2.13

* 20

* 42

* 01

* 01

* 22

* 25

* 06

* 44

* 45

* 01

* 24

* 41

* 01

Programming the Directory Code Length# Key - Insert an Amount of “Pause Time” Between Phone Number DigitsProgramming Phone Numbers - Up to 16-DigitsDeleting Individual Phone NumberDeleting ALL Phone Numbers CAUTIONDisplay / DELETE Phone Numbers with UNKNOWN Directory CodesDisplay Phone Numbers with KNOWN Directory Codes 7-Digit Phone Number Capability CAUTION 16-Digit Phone Number Capability CAUTION Programming 7-Digit Phone Numbers Programming Area Codes (Area Code Reference Numbers) Programming Phone Numbers WITH Area Code Reference Numbers Deleting Individual 7-Digit Phone Number

7-Di

git P

hone

#- L

imite

d Us

e - These

sections are NOT used for Factory Set

16-DigitPhone Number Programming

Page 4: Telephone Entry System - Doorking

4 1800-060 Issued 7-19Version B

SPECIFICATIONS

Features

1803 / 1808 / 1810 Telephone Entry Systems, Circuit Board 1862-010 REV O or Higher.

DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.

1803Flush Mount

1808Surface Mount

1810Surface Mount

7788

99

4455

66

1122

33

00

Push Button

Push ButtonTo CallTo Call

7788

99

4455

66

1122

33

00Operating Instructions

1. Locate Code Number On Directory

2. Press Code Number. If Line Is Busy, Press Any Button

to Hang-Up. Try Again.

3. Enter On “OPEN” Display or Tone.

NAMEAdams JAkins MAnnese JAnderson HApplegate BAustin DBalsbaugh BBass J

Bejar IBerlin JBernard EBillings LBroker TBrose SBrown JBrown KBryant WByron RByan G

009115352551656078221321249476003112292822491324231332117

CODENAMEByers MCardillo PCarney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill P

Dillon MDixon DDominick PDonick PDonner KDonter F

807503501404461249772633481104322068888518358467765954992

CODE

NAMEDorland TDownward LDubreuil MDukes DEnghard LEllis W

Farago FFarrow MFernandez SGarfield S

Hitch JHitch FHodges AHoover HJensen DJohnson MJohnson TJones AJones G

186232333835302064005490341879557032419

Mancini GMastin DMaston FMozina JMucera JMulin BNabor KNabur JNeumann JNixon RPatterson FPerez FPetrolli ARay J

338476101069247122040640447006745546501330211543987352

Seeley JSelleck HShaer RShank DSimons LSmith JSomach HSteele FStollach HSynfol ATomlinson LTompson ATompson STyler QWashington GWashington KWent LWhiting MWinston FWyatt J

081148887063883551731435055082650791021076100334213229007134609389679211670441

CODE

Operating Instructions

cate Code Number On Directory

ess Code Number. If Line Is Busy, Press Any Button

Hang-Up. Try Again.

nter On “OPEN” Display or Tone.

JM

e Json Hgate Bn Dbaugh Bs Jar Irlin Jrnard Ellings Lroker TBrose SBrown JBrown KBryant WByron RByan G

009115352551656078221321249476003112292822491324231332117

CODENAMEByers MCardillo PCarney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill P

Dillon MDixon DDominick PDonick PDonner KDonter F

807503501404461249772633481104322068888518358467765954992

CODE

NAMEDorland TDownward LDubreuil MDukes DEnghard LEllis W

Farago FFarrow MFernandez SGarfield S

Hitch JHitch FHodges AHoover HJensen DJohnson MJohnson TJones AJones G

186232333835302064005490341879557032419

Mancini GMastin DMaston FMozina JMucera JMulin BNabor KNabur JNeumann JNixon RPatterson FPerez FPetrolli ARay J

338476101069247122040640447006745546501330211543987352

Seeley JSelleck HShaer RShank DSimons LSmith JSomach HSteele FStollach HSynfol ATomlinson LTompson ATompson STyler QWashington GWashington KWent LWhiting MWinston FWyatt J

081148887063883551731435055082650791021076100334213229007134609389679211670441

CODE

TELEPHONE ENTRY SYSTEM

OPERATING INSTRUCTIONS

Locate Code Number on Directory.

Press Code Number. If Line is Busy,

Press “#” to Hang UP. Try Again.

Enter on Tone.

1.2.

3.

7788

99

4455

66

1122

33

00

• THREE different types of connection options, DKS Cellular, VoIP over the Internet or POTS telephone line.

• Provides service for up to 600 residents but can be reprogrammed to provide service for up to 1000 residents.

• System can be programmed from the front keypad.

• System can be programmed remotely using a touch-tone telephone.

• System keypad will emit DTMF tones after a call is answered allowing the system to be used with auto-attendants, answering machines, etc.

• Directory codes can be set from 1 to 4 digits in length and can be randomly assigned.

• Up to 16-digit phone number dialing with optional pauses between digits when necessary.

• Two internal relays allow the system to control a main entry point plus an additional entry point.

• Built in time clock provides hold open time zones, entry code time zones and “Flash” entry codes.

• 5-digit entry codes available for special needs.

• 2 programmable switch inputs can be set to activate a relay or dial a preprogrammed phone number.

Included with the system is an extra random keyed cabinet lock. If desired, for added security against unauthorized entry into the system, the standard lock may be replaced with the random lock.Note: DoorKing cannot replace this specific lock or keys if lost.

Page 5: Telephone Entry System - Doorking

11800-060 Issued 7-19Version B

TABLE OF CONTENTS

Important Notices FCC - United States, DOC - Canada Glossary General Information Installation Guidelines and Safety Information

SECTION 1 - INSTALLATION 1.1 General Installation 1.1.1 Remove Components from Enclosure 1.2.1 Install Enclosure for 1803 & 1810

1.2 1803 & 1810 Surface Mount Dimensions 1.2.1 Surface Mount Recess Kit Installation for 1803 & 1810

1.3 1803 & 1810 Flush Mount Dimensions 1.3.1 Flush Mount Kit Installation for 1803 & 1810 1.3.2 Self-Standing Lighted Kiosk for 1803 & 1810 1.3.3 Flush Mount Surface Mounting Kit Installation for 1803 & 1810

1.4 1808 Dimensions and Installation 1.5 Memory Chip Replacement 1.6 Postal Lock Installation 1.7 UL 294 Compliant Tamper Switch

SECTION 2 - WIRING 2.1 Wiring Guidelines 2.1.1 Power 2.1.2 Wire Runs 2.1.3 Grounding 2.1.4 Surge Suppression 2.1.5 Ferrite Filter

2.2 Terminal Descriptions 2.3 Telephone Entry System Wiring and Adjustments 2.3.1 Speaker Volume, Microphone and Feedback 2.3.2 Click Sensitivity - Use for Rotary-Dial Phones ONLY 2.3.3 LCD Display Contrast for 1803 & 1810 2.3.4 Master Code Switch 2.3.5 Ring Pin Jumper 2.3.6 Hands Free - Hand Set Jumper

2.4 Phone (Voice) Connection Options

SECTION 3 - PROGRAMMING 3.1 General Programming 3.1.1 Master Code Overview for System Programming 3.1.2 Single or Multiple Systems 3.1.3 Relay Strike Time 3.1.4 “Tone Open” Sound ON or OFF 3.1.5 Talk Time 3.1.6 Tone Open Numbers 3.1.7 Programming Switch Input 1 and Switch Input 2 3.1.8 Number of Rings Before Telephone Entry System will Answer 3.1.9 PBX Line Access Code Programming 3.1.10 Star Key Function 3.1.11 Keypad Function (DTMF Tone Programming) 3.1.12 System to Stay On-Line or Hang-Up after Touch Tone Number Pressed 3.1.13 Automatic Hang-Up Function

33

4

5 5

67

89

1011

1213

14 15

1617

181818

19 19 19 19

20 21 22 22 22 23 23 23

24-25

26 26

26 27

28 28 28 28 29 29 29 30 30 30 30 31

Table of Contents continued on next page

Page 6: Telephone Entry System - Doorking

2 1800-060 Issued 7-19Version B

TABLE OF CONTENTS

SECTION 3 - PROGRAMMING Continued 3.2 Phone Number Programming 3.2.1 Programming the Directory Code Length 3.2.2 # Key - Insert an Amount of “Pause Time” Between Phone Number Digits 3.2.3 Programming Phone Numbers - Up to 16-Digits 3.2.4 Deleting Individual Phone Number 3.2.5 Deleting ALL Phone Numbers 3.2.6 Display / Delete Phone Numbers with UNKNOWN Directory Codes 3.2.7 Display Phone Numbers with KNOWN Directory Codes 3.2.8 7-Digit Phone Number Capability 3.2.9 16-Digit Phone Number Capability 3.2.10 Programming 7-Digit Phone Numbers 3.2.11 Programming Area Codes (Area Code Reference Numbers) 3.2.12 Programming Area Codes WITH Area Code Reference Numbers 3.2.13 Deleting Individual 7-Digit Phone Number

3.3 Entry Code Programming 3.3.1 Programming Four-Digit Entry Code 3.3.2 Delete Individual Four-Digit Entry Code 3.3.3 Delete ALL Four-Digit Entry Codes 3.3.4 Four-Digit Entry Code Divide Number to Activate Relays 3.3.5 Four-Digit Entry Code (Reverse Relay Activation ONLY) 3.3.6 Programming Five-Digit Entry Code 3.3.7 Delete Individual Five-Digit Entry Code 3.3.8 Delete ALL Five-Digit Entry Codes 3.3.9 Five-Digit Entry Code Divide Number to Activate Relays

3.4 Time Functions Programming 3.4.1 Programming Time Clock 3.4.2 Automatic Relay Activation Time Zones 3.4.3 Four-Digit Entry Codes Time Zone 3.4.4 Five-Digit Entry Codes Time Zone 3.4.5 “Flash Entry Codes” Active for ONE-DAY ONLY

SECTION 4 - SYSTEM OPERATING INSTRUCTIONS 4.1 General Instructions 4.1.1 Guest Instructions 4.1.2 Responding to a Guest Call 4.1.3 Using an Entry Code

4.2 System Administrator 4.2.1 Remote Programming (Touch-Tone Phone) 4.2.2 Remote Relay Activation 4.2.3 Remote Relay Check 4.2.4 Remote Entry Code Time Zone Enable / Disable 4.2.5 Remote Automatic Relay Time Zone Enable / Disable

4.3 Miscellaneous Operating Instructions 4.3.1 Switch Input 1 & 2 Switch Operation 4.3.2 Talk Time 4.3.3 Phone Line Sharing for Multiple Telephone Entry Systems 4.3.4 Connection to a PBX 4.3.5 Areas with 10-Digit Dialing

SECTION 5 - MAINTENANCE 5.1 Replacement Parts 5.2 Troubleshooting 5.3 Accessories Wiring Schematic

SECTION 6 - LOG TABLES

RESIDENT INSTRUCTIONS

32 32 32 33 33 34 34 34

353536363737

38383838383939393937

404040414242

4343434343

444444444545

464646464646

4747

47-484949

50-52

53

7-Di

git P

hone

#- L

imite

d Us

e -

NOT used for Factory Set 16-DigitPhone Number Programming

Page 7: Telephone Entry System - Doorking

31800-060 Issued 7-19Version B

FCC – United StatesThis equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules and Regulations. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.FCC Registration Number: DUF6VT-12874-OT-T

DOC - CanadaThe Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the users satisfaction.Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable means of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.Users should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.DOC Registration Number: 1736 4528 A

Notice:The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the require-ment that the sum of the load numbers of all the devices does not exceed 100.

Notice:DoorKing does not provide a power transformer on units sold outside of the United States. Use only transformers that are listed by a recognized testing laboratory to power the telephone entry system. An Inherently Protected Transformer must be used to power this device. The Telephone Entry systems require a 16.5-volt, 20 VA transformer.

Listing:This product has been tested to and found to be in compliance with the UL 294 Safety Standard and Certified to CAN/ULC-S319-05 by Intertek Testing Services NA Inc. (a Nationally Recognized Testing Laboratory) and is ETL listed.

Important Notices

Performance LevelsDestructive Attack: Level I Line Security: Level I Endurance: Level IV Standby Power: Level I (Level II with 12 VDC, .7 Ah, SLA battery, required Single Point Locking Device with Key Locks: Level I

ACCESS CONTROL SYSTEM: A collection of means, measures and specific practices that when combined, form or compose a systematic approach, which enables an authority to control access to areas and resources in a given physical facility. An access control system, within the field of physical security, is generally seen as the second layer in the security of a physical structure.

ALARM: A condition indicating a state of alert or tamper detection.

ALARM SIGNAL: A transmission of an alarm condition or alarm report.

CONTROLLED AREA: A room, office, building, facility, premises, or grounds to which access is monitored, limited, or controlled.

EQUIPMENT: Any part of an electronic access control system, such as access control units, reader interface modules, access point actuators, access point sensors, keypads, and the like.

PROTECTED AREA: A room, office, building, facility, premise or grounds to which access is monitored, and limited and/or controlled, whereby the authorized person of the Access Control System may grant access to non-authorized persons.

RESTRICTED AREA: A room, office, building, facility, premise or grounds to which access is monitored, and limited and strictly controlled, whereby only the administrator of the Access Control System shall issue credentials that will lead to access.

Glossaryfor Canadian certification)

Page 8: Telephone Entry System - Doorking

4 1800-060 Issued 7-19Version B

General Information• Prior to beginning the installation of the telephone entry system, we suggest that you become familiar with the instructions, illustrations, and wiring guidelines in this manual. This will help insure that you installation is performed in an efficient and professional manner.

• The proper installation of the telephone entry panel is an extremely important and integral part of the overall access control system. Check all local building ordinances and building codes prior to installing this system. Be sure your installation is in compliance with local codes.

• When used to control a door or pedestrian gate, try to locate the telephone entry system as near as possible to the entry point. The unit should be mounted on a rigid wall to prevent excessive shock and vibration from closing doors or gates. Continuous vibration and shock from slamming doors or spring-loaded pedestrian gates will damage the circuit board. Under no circumstances should the unit be mounted directly to a moving door or gate.

• ADA mounting requirements for door control (Ref: ICC/ANSI A117.1-2009). The requirements below apply ONLY when the telephone entry system is being used to control entry through A PUBLIC DOOR ONLY. If this system is used to control entry through a vehicular gate or private entrance, the dimensions noted below do not apply.

• When used to control a vehicular gate with an automatic gate operator, the telephone entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and/or touch the gate or gate operator at the same time.

• Be sure that the system is installed so that it is not directly in the traffic lane. Goose neck mounting post and kiosks work well for these type systems. When planning where to locate the system, take into consideration traffic lane layouts, turn around lanes for rejected access, conduit runs, power availability, etc.

• Environmental factors must also be taken into account. Surface mount units are designed for direct outdoor installations, however it is preferable to protect them from direct exposure to driven rain or snow whenever possible. Flush mount units must be protected from direct exposure to the elements.

• This telephone entry system contains a number of static sensitive components that can be damaged or destroyed by static discharges during installation or use. Discharge any static prior to removing the circuit board from the lobby panel by touching a proper ground device.

• Instruct the end user to read and follow these instructions. Instruct the end user to never let children play with or operate any access control device. This Owner’s Manual is the property of the end user and must be left with them when installation is complete.

1. Unobstructed Forward Reach. Where a clear floor or ground space allows only a forward approach to an object and is unobstructed, mounting height shall be a minimum of 15 inches (381 mm), and a maximum of 48 inches (1.22 m), above the floor or ground to the operable controls.

48”

15”MinimumHeight

MaximumHeight

3. Unobstructed Side Reach. Where a clear floor or ground space allows a parallel approach to an object and the side reach is unobstructed, and the edge of the clear floor space is 10 inches (255 mm) maximum from the object, mounting height shall be a minimum of 15 inches (380 mm), and a maximum of 48 inches (1.22 m), above the floor or ground to the operable controls.

10”

48”MaximumHeight

Maximum Length ofClear Floor Space

15”Minimum

Height

10” Maximum Length ofClear Floor Space

4. OBSTRUCTED HIGH Side Reach. If the side reach is over an obstruction 10 inches or less, mounting height shall be a maximum of 48 inches (1.21 m) above the floor or ground to the operable controls. If the side reach is over an obstruction greater than 10 inches, but less than 24 inches, mounting height shall be a maximum of 46 inches (1.17 m) above the floor or ground to the operable controls.

MaximumHeight

10” or Less

48”

34”

MaximumHeight 46”

34”

Greater than 10”Less than 24”

2. OBSTRUCTED HIGH Forward Reach. If the high forward reach is over an obstruction, reach and clearances shall be as shown. NOTE: If the height of a control is 48" maximum, then the length of the obstruction must be 20" or less. If the height of a control is 44" maximum, then the length of the obstruction may be increased to 25" or less.

48”Maximum

Height MaximumHeight

25” or Less

44”

20” or Less

Page 9: Telephone Entry System - Doorking

51800-060 Issued 7-19Version B

SECTION 1 - INSTALLATION

There are 2 different styles of the telephone entry systems (Surface mounts and Flush mounts-1803/1810 only), and different ways to mount them (On a wall, in a wall, attached to a architectural style post, kiosk, etc). Models will ALL need power and communication wires run to them in conduit or inside a architectural style post. Feed all of the wires through the back or bottom of the entry system using the existing knock-outs provided in the enclosures. DO NOT make any new holes in the enclosure to feed wires through. Keep ALL the entry system’s wires away from any existing high voltage power wires a minimum of 6” to help prevent any noise and hum pickup in the system’s phone line. The system MUST also be properly grounded to function correctly.

WARNING If this telephone entry system is used to control a vehicular gate with an automatic gate operator, the telephone entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that the user cannot come into contact with the gate or gate operator when using this entry system.

The telephone entry system contains static sensitive components that can be damaged or destroyed by static discharges during installation. Discharge any static prior to removing the circuit board by touching a proper ground device. GREAT care must be taken after removing the components from the enclosure to protect them throughout the installation. Carelessness on your part is NOT covered under warranty.

Make sure ALL dirt, metal or wood debris is removed from inside the enclosure after mounting it. A through cleaning of the enclosure is needed before re-installing the components back into the system and wiring it. Any debris left inside could damage the control board and cause the telephone entry system to malfunction during operation.

1.1 General Installation

DoorKingMounting Post

Surface Mount Only

Outside Wall Inside WallLighted-CoveredKiosk

DoorKing Self-StandingLighted Kiosk, 1803 and1810 Flush Mounts Only

Included with the system is an extra random keyed cabinet lock. If desired, for added security against unauthorized entry into the system, the standard lock may be replaced with the random lock. Note: DoorKing cannot replace this specific lock or keys if lost.

Prior to installing the telephone entry system, we suggest that you become familiar with the instructions, illustrations, and wiring guidelines in this manual. This will help insure that you installation is performed in an efficient and professional manner.

DO NOT install the telephone entry system next to landscape sprinklers or in any area that may expose the system to direct driven water.

First you must determine how you would like to connect your telephone entry system for voice communication. The method you choose is dependent on the type of connection available at the entry system location. There are THREE types of connections:(See Section 2.4 Phone (Voice) Connection Options for more information)

Note: After choosing your connection type, you may need to purchase additional equipment or devices before your installation can be completed.

Wireless connection – uses DKS cellular (Voice ONLY) service.1Network cable connection – uses DKS VoIP over the Internet or third party providers of your own choosing.2Telephone line connection – uses a POTS telephone line.3

7788

994455

661122

33

00

TELEPHONE ENTRY SYSTEM

1.

2.

3.

OPERATING IN

STRUCTIONS

Locate Code Number on Dire

ctory.

Press Code Number. If L

ine is Busy,

Press “#” to Hang UP. T

ry Again.

Enter on Tone.

Page 10: Telephone Entry System - Doorking

6 1800-060 Issued 7-19Version B

FaceplateHingeLocknuts

Enclosure

1803

Surface

Mount

Circuit BoardScrew

Main Terminal Screw

GroundWire

Main Terminal16AC

16AC

NONC

CBAT

COM

SPKR

MIC

MICG

PSW

CGND

PHONE

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

MASTERCODE

NO

HS

TONEOFF

TONEON

HF

NCC

CONTRASTDOORKING 1862-010

1810

-075

sn X

XTH

IS S

IDE

UP

0000

0101

0001

0

1.1.1 Remove Components from Enclosure

1. Disconnect the keypad ribbon cable from the circuit board.

2. Remove the screw from the top of the circuit board.

3. GENTLY remove the circuit board by pulling it out of the main terminal.

4. Remove the two screws from the main terminal and remove the ground wire locknut.

5. Remove the locknuts from the faceplate hinge.

6. Remove the faceplate, main terminal (still wired), store them in a Safe Place until they need to be re-installed.

7. Proceed to section 1.2.1 for 1803 & 1810 models. Go to section 1.4 for 1808 model.

There are 2 different styles of telephone entry systems - Surface mounts and Flush mount. The basic component removal is the same for all models, 1803 surface mount is shown as an example.

RibbonCable

Faceplate

Discharge any static BEFORE removing the circuit board by touching a proper

ground device.

DOORKINGInglewood, Ca 90301

Model # 1800 Series

Serial #Complies F.C.C. Part 68

F.C.C. Registration #

DUF6VT-12874-OT-T

Ringer Equiv. 0.0A

Jack USOC RJ11C or W

ACCESS CONTROL

SYSTEM UNITS

CONFORMS TO UL STD 294

OUTDOOR USE / WET

D O O R K I N G ® , I N C .MADEINUSA

PART NUMBER

REV

SERIAL NO.

D O O R K I N G ® , I N C .

Mfg. in U.S.A.Access Control Solutions

Since 1948

This product is manufactured under one

or more of the following U. S. Patents.

OTHER PATENTS PENDING

DOORKING INC., INGLEWOOD CA

Patent No.Date

Patent No.Date

Page 11: Telephone Entry System - Doorking

71800-060 Issued 7-19Version B

1.1.2 Install Enclosure for 1803 & 1810

1. Mount the enclosure using the mounting holes provided in the corners (see sections 1.2 and 1.3 for your chosen model dimensions including kit installations). Be sure that mounting screws (Not supplied) do not protrude into the enclosure where they could cause a short on the back of the circuit board. Make any necessary conduit connections through the back or bottom of the enclosure using the existing conduit knock-outs. DO NOT make any new conduit holes in the enclosure.2. Route all wiring through conduit or architectural post (not supplied) into enclosure.3. Clean out the enclosure. Make sure that all dirt, metal and/or wood debris is removed.4. Re-install components back into the enclosure (Reverse section 1.1.1 steps on previous page). Use the wiring schematics in the back of this manual to help re-install the components if necessary. DO NOT apply any power at this time.

There are 2 different styles for the 1803 & 1810 - surface and flush mount. The illustrations below show typical installations but specific installations can vary from this.

Use hardware supplied with architectural post to secure enclosure to post.

Surface MountEnclosure

Mounting Hole

Knock-out

Use appropriate hardware to secure enclosure to the wall (not supplied).

Mount ON a Surface(See sections 1.2).

Mount IN a Surface(See sections 1.2.1 and 1.3.1 and 1.3.2).

Mount to anArchitecturalMountingPost

Examples of conduit runs that may be used, depending on how you choose to run the wiring. Some installations will allow the conduit to be run outside the wall and connect to the bottom of the enclosure but this is generally NOT recommended.

Run all wires inside post.

Conduit runto junction box Conduit

sweep run

Wall

Flush MountEnclosure

Plastic Spacer

Locknut

Knock-outs

Rough-InBox

TrimRingMounting Screws

(Not supplied)

Wall

Surface MountEnclosure

Mounting Hole

Knock-out

Note: An architectural mounting post anchored in concrete does not make a good ground.

Page 12: Telephone Entry System - Doorking

8 1800-060 Issued 7-19Version B

7788

99

4455

66

1122

33

0012

to Hang-Up. Try Again.

3

NAME

Balsbaugh BBass JBejar IBerlin JBernard EBillings LBroker TBrose SBrown JBrown KBryant WByron RByan G

551656078221321249476003112292822491324231332117

Cardillo PCarney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill PDillon MDixon DDominick PDonick PDonner KDonter F

807503501404461249772633481104322068888518358467765954992

CODE

Dorland TDownward LDubreuil MDukes DEnghard LEllis WFarago FFarrow MFernandez SGarfield SGarreau JGentry MGonzalez HHaberfeld AHammer VHendrix KHird A

Hitch J

Johnson MJohnson TJones AJones G

005490341879557032419

CODE

Mulin BNabor KNabur JNeumann JNixon RPatterson FPerez FPetrolli ARay J

122040640447006745546501330211543987352

Smith JSomach HSteele FStollach HSynfol ATomlinson LTompson ATompson STyler QWashington GWashington KWent LWhiting MWinston FWyatt J

081148887063883551731435055082650791021076100334213229007134609389679211670441

CODE

1.2 1803 & 1810 Surface Mount DimensionsSurface mount units can be mounted directly to a wall, pilaster, post mounted using a DoorKing architectural style mounting post (P/N 1200-037 and 1200-038) or recessed in a wall (see next page) with the surface mount recess kit (P/N 1803-150). Be sure the unit is mounted securely and is not subject to vibration from closing doors or gates.

13”

13”

11.25”

11.25”

4.5”

3”

Bottom View

Bottom View

Side ViewBack View Front View

Side ViewBack View Front View

7788

99

4455

66

1122

33

00

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONS

Locate Code Number on Directory.

Press Code Number. If Line is Busy,

Press “#” to Hang UP. Try Again.

Enter on Tone.

1.2.

3.

1810

1803

Hang-Up. Try Again.

baugh Bs Jar Irlin Jrnard Ellings Lroker TBrose SBrown JBrown KBryant WByron RByan G

551656078221321249476003112292822491324231332117

Cardillo PCarney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill PDillon MDixon DDominick PDonick PDonner KDonter F

807503501404461249772633481104322068888518358467765954992

CODE

Dorland TDownward LDubreuil MDukes DEnghard LEllis WFarago FFarrow MFernandez SGarfield SGarreau JGentry MGonzalez HHaberfeld AHammer VHendrix KHird A

Hitch J

Johnson MJohnson TJones AJones G

005490341879557032419

CODE

Mulin BNabor KNabur JNeumann JNixon RPatterson FPerez FPetrolli ARay J

122040640447006745546501330211543987352

Smith JSomach HSteele FStollach HSynfol ATomlinson LTompson ATompson STyler QWashington GWashington KWent LWhiting MWinston FWyatt J

081148887063883551731435055082650791021076100334213229007134609389679211670441

CODE

77 88 99

44 55 66

11 22 33

00

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONSLocate Code Number on Directory.Press Code Number. If Line is Busy,Press “#” to Hang UP. Try Again.Enter on Tone.

1.2.

3.

TELEPHONE ENTRY SYSTEM

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

.875” Dia

6” 1.625”2.625”

.875” Dia

6” 1.625”2.625”

10.125”

.5”

2.625”

8.625”

1”10

.875

1.12

5”

9”

.25” Dia. Mounting Hole

.875” Dia

4.75”

3.25”

10.125”

.5”

2.625”

8.625”

1”1.125”

10.8

75”

1.12

5”

9”

5.625”

.25” Dia. Mounting Hole

.875” Dia

WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time.

Page 13: Telephone Entry System - Doorking

91800-060 Issued 7-19Version B

Bottom View

Side ViewFront View

Recess Box

Threaded Stud

1.2.1 Surface Mount Recess Kit Installation for 1803 & 18101803 & 1810 surface mount units can be recessed into a wall or pilaster by using the optional surface mount recess kit if desired (P/N 1803-150). This allows a recessed 1810 telephone entry system to have a lighted keypad which the flush mount unit DOES NOT have. The recess box gets installed in the wall. Use appropriate hardware (not included) to secure the box in the wall. Run all necessary conduit (not included) to the recess box. Slide the enclosure in the recess box and secure it with the hardware included in the kit. Be sure the unit is mounted securely and is not subject to vibration from closing doors or gates.

9”

11.25”

6”

6”

2.625”

2.625”

.4”

.4”

3.2”

1”

8.5”

13.2

5”

2.625”

1.125”

2.5”

25” Dia. Mounting Hole

1.375” Dia.

15.25”13.25”

13.375” 3.625”

MountingHoles

.25” Dia.

Knock-outs

Surface MountEnclosure

Plastic Spacer

Locknut

RecessBox

Mounting Screws (Not supplied)

Mount In a SurfaceWall

7788

99

4455

66

1122

33

00NAMEAdams JAkins MAnnese JAnderson HApplegate BAustin DBalsbaugh BBass J

Bejar IBerlin JBernard EBillings LBroker TBrose SBrown JBrown KBryant WByron RByan G

009115352551656078221321249476003112292822491324231332117

CODENAMEByers MCardillo PCarney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill P

Dillon MDixon DDominick PDonick PDonner KDonter F

807503501404461249772633481104322068888518358467765954992

CODE

NAMEDorland TDownward LDubreuil MDukes DEnghard LEllis W

Farago FFarrow MFernandez SGarfield SGarreau JGentry MGonzalez HHaberfeld AHammer VHendrix KHird AHitch JHitch FHodges AHoover HJensen DJohnson MJohnson TJones AJones G

290152028072828342733441612914542120732186232333835302064005490341879557032419

CODENAMEJordan MJorden LJorgensen BKlein D

Knoblich BLamb BLand DLanders SLangstrom BLevine DLewis BLucidi BMancini GMastin DMaston FMozina JMucera JMulin BNabor KNabur JNeumann JNixon RPatterson FPerez FPetrolli ARay J

023562647736408803026996338476101069247122040640447006745546501330211543987352

CODE

NAMEReese DReiger BRemington S

Ressegieu RRollins ASchuster SSeeley JSelleck HShaer RShank DSimons LSmith JSomach HSteele FStollach HSynfol ATomlinson LTompson ATompson STyler QWashington GWashington KWent LWhiting MWinston FWyatt J

081148887063883551731435055082650791021076100334213229007134609389679211670441

CODE

WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time.

Page 14: Telephone Entry System - Doorking

10 1800-060 Issued 7-19Version B

7788

99

4455

66

1122

33

00Operating Instructions

1. Locate Code Number On Directory

2. Press Code Number. If Line Is Busy, Press Any Button

to Hang-Up. Try Again.

3. Enter On “OPEN” Display or Tone.

NAMEAdams JAkins MAnnese JAnderson HApplegate BAustin DBalsbaugh BBass J

Bejar IBerlin JBernard EBillings LBroker TBrose SBrown JBrown KBryant WByron RByan G

009115352551656078221321249476003112292822491324231332117

CODENAMEByers MCardillo PCarney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill P

Dillon MDixon DDominick PDonick PDonner KDonter F

807503501404461249772633481104322068888518358467765954992

CODE

NAMEDorland TDownward LDubreuil MDukes DEnghard LEllis W

Farago FFarrow MFernandez SGarfield SGarreau JGentry MGonzalez HHaberfeld AHammer VHendrix KHird AHitch JHitch FHodges AHoover HJensen DJohnson MJohnson TJones AJones G

290152028072828342733441612914542120732186232333835302064005490341879557032419

CODENAMEJordan MJorden LJorgensen BKlein D

Knoblich BLamb BLand DLanders SLangstrom BLevine DLewis BLucidi BMancini GMastin DMaston FMozina JMucera JMulin BNabor KNabur JNeumann JNixon RPatterson FPerez FPetrolli ARay J

803026996338476101069247122040640447006745546501330211543987352

Remington SRessegieu RRollins ASchuster SSeeley JSelleck HShaer RShank DSimons LSmith JSomach HSteele FStollach HSynfol ATomlinson LTompson ATompson STyler Q

Washington GWashington KWent LWhiting MWinston FWyatt J

081148887063883551731435055082650791021076100334213229007134609389679211670441

CODE

Operating Instructions

cate Code Number On Directory

ess Code Number. If Line Is Busy, Press Any Button

Hang-Up. Try Again.

nter On “OPEN” Display or Tone.

JM

e Json Hegate Bn Dbaugh Bs Jar Irlin Jrnard Ellings Lroker TBrose SBrown JBrown KBryant WByron RByan G

009115352551656078221321249476003112292822491324231332117

CODENAMEByers MCardillo PCarney PCollins GColyer RCordula DCourt ECrains GDalton BDaniels RDawls JDeLahae MDill P

Dillon MDixon DDominick PDonick PDonner KDonter F

807503501404461249772633481104322068888518358467765954992

CODE

NAMEDorland TDownward LDubreuil MDukes DEnghard LEllis W

Farago FFarrow MFernandez SGarfield SGarreau JGentry MGonzalez HHaberfeld AHammer VHendrix KHird AHitch JHitch FHodges AHoover HJensen DJohnson MJohnson TJones AJones G

290152028072828342733441612914542120732186232333835302064005490341879557032419

CODENAMEJordan MJorden LJorgensen BKlein D

Knoblich BLamb BLand DLanders SLangstrom BLevine DLewis BLucidi BMancini GMastin DMaston FMozina JMucera JMulin BNabor KNabur JNeumann JNixon RPatterson FPerez FPetrolli ARay J

803026996338476101069247122040640447006745546501330211543987352

Remington SRessegieu RRollins ASchuster SSeeley JSelleck HShaer RShank DSimons LSmith JSomach HSteele FStollach HSynfol ATomlinson LTompson ATompson STyler Q

Washington GWashington KWent LWhiting MWinston FWyatt J

081148887063883551731435055082650791021076100334213229007134609389679211670441

CODE

TELEPHONE ENTRY SYSTEM

OPERATING INSTRUCTIONS

Locate Code Number on Directory.

Press Code Number. If Line is Busy,

Press “#” to Hang UP. Try Again.

Enter on Tone.

1.2.

3.

7788

99

4455

66

1122

33

00

1.3 1803 & 1810 Flush Mount Dimensions

13.5”13”

12”11.25” 3”

3”

Bottom View

Side ViewBack View Front View

1803

6” 1.5”2.625”

.25”

2.75”

10.125”.5”

2.625”3”

1” .875”

.5”

.875”

10.875”

1.12

5”

9”

3”

25” Dia. Mounting Hole

.875” Dia

.875” Dia

1810

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

Flush mount 1803 & 1810 are installed with a flush mount kit P/N 1814-165 (stainless) or 1814-166 (gold). Flush mount kits are NOT INCLUDED with the flush mount entry system (See next page for flush mount kit installation).DoorKing offers a self-standing lighted kiosk for the flush mount unit ideal for walk-up pedestrian applications P/N 1200-170 (See page 12 for self-standing kiosk installation).The flush mount units may also be installed ON the surface of a wall with a flush mount surface mounting kit if desired P/N 1814-152 (silver only). Flush mount surface mounting kits are NOT INCLUDED with the flush mount entry system (See page 13 for flush mount surface mounting kit installation).

Flush mount 1803 & 1810 are installed into a wall/kiosk and can be mounted outside, exposed to the weather. It is preferred that they have limited direct exposure to the weather. We suggest that when they are mounted outdoors, it is in a covered protected area. Be sure the unit is mounted securely and is not subject to vibration from closing doors or gates.

WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time.

Page 15: Telephone Entry System - Doorking

111800-060 Issued 7-19Version B

7788

99

4455

66

1122

33

00

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONS

Locate Code Number on Directory.

Press Code Number. If Line is Busy,

Press “#” to Hang UP. Try Again.

Enter on Tone.

1.2.

3.

14.6” 16”

12.8”3.45”14.7” 3.45”

Bottom ViewBottom View

Side ViewSide View

Front ViewFront View

1.3.1 Flush Mount Kit Installation for 1803 & 1810The flush mount kit has two parts; the rough-in box and the trim ring. The rough-in box is installed in the wall first. Use appropriate hardware (not included) to secure the box in the wall. Run all necessary conduit (not included) to rough-in box. Slide the trim ring into the rough-in box. Slide the enclosure in the trim ring and secure them all together with the hardware included in the kit. Be sure the unit is mounted securely and is not subject to vibration from closing doors or gates. See previous page for flush mount enclosure dimensions.

3.4”3”

1.685”

1.74”

1.8”

3”3.4”

6”3.4” 3.4”

1.5”

1.74” 1.71”

Hole for Threaded Stud

MountingHole

Threaded Stud

1.125” Dia

1.125” Dia

Rough-In Box Trim Ring

Flush MountEnclosure

Plastic Spacer

Locknut

Knock-outs

Rough-InBox

TrimRing

MountingHoles

.25” Dia.

Mounting Screws

(Not supplied)

Mount In a Surface

Wall

WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time.

Page 16: Telephone Entry System - Doorking

12 1800-060 Issued 7-19Version B

1.3.2 Self-Standing Lighted Kiosk Installation for 1803 & 1810

10”

18.5”

60”

The flush mount kit (Sold separately) is installed into the self-standing kiosk (P/N 1200-170) to secure the flush mount 1803 or 1810 in place.Secure the rough-in box in the kiosk. Run all necessary wires to rough-in box. Slide the trim ring into the rough-in box. Slide the enclosure in the trim ring and secure them all together with hardware included in the kit. Flush Mount

Enclosure

Plastic Spacer

Locknut

Knock-outs

Rough-InBox

TrimRing

WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time.

Page 17: Telephone Entry System - Doorking

131800-060 Issued 7-19Version B

13.5”

12” 2.625”

Bottom View

Side ViewFront View

1.3.3 Flush Mount Surface Mounting Kit Installation for 1803 & 1810Flush mount unit (See page 10 for flush mount enclosure dimensions) can be mounted ON a wall or pilaster and NOT IN the wall by using the optional flush mount surface mounting kit (P/N 1814-152). This is useful when cutting a large hole into a wall or pilaster would be very difficult (marble or granite for example) .The flush mount surface mounting kit is a trim ring that fits around the flush mount enclo-sure. The enclosure and trim ring get installed directly on the wall using appropriate hardware (not included) after running all necessary conduit to the enclosure. Be sure the unit is mounted securely and is not subject to vibration from closing doors or gates.

Examples of some small holes in the wall that may be needed, depending on how you choose to run the wiring.

1”

.375”

Trim Ring

Flush MountEnclosure

Knock-outs

Mounting Screws

(Not supplied)

Wall

Trim Ring

1.125” Dia

1.5”3” 3” 3”

1.125” Sq

1.5”

.875”

1.125”

.875” 1”

Conduit runto junction box

Conduitsweeprun

Mount On a Surface

7788

99

4455

66

1122

33

00

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONS

Locate Code Number on Directory.

Press Code Number. If Line is Busy,

Press “#” to Hang UP. Try Again.

Enter on Tone.

1.2.

3.

WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time.

Page 18: Telephone Entry System - Doorking

14 1800-060 Issued 7-19Version B

1.4 1808 Dimensions and Installation1808 units can be mounted directly to a wall, pilaster, post mounted using a DoorKing mounting post (P/N 1200-045 or 1200-046). Be sure the unit is mounted securely and is not subject to vibration from closing doors or gates.

7.5”

11”

Side ViewBack View Front View

1808

1808 with Directory

7788

99

4455

66

1122

33

00

Push Button

Push ButtonTo CallTo Call

7788

99

4455

66

1122

33

00

NAMEAdams JBernard EBrown LDavis THodges SMiller JSmith KThomas WZimmer R

195246837

CODE

NAMEAdams JBernard EBrown LDavis THodges SMiller JSmith KThomas WZimmer R

195246837

CODE

77 88 99

44 55 66

11 22 33

00

NAMEAdams JBernard EBrown LDavis THodges SMiller JSmith KThomas WZimmer R

195246837

CODE

Bottom View

.875” Dia

.875” Dia

5”2.625”

3”

6.5”

4.75”

4.25”

6.75”

2.5”

2.5”

2.5”

2.5” 4.25”

Use existing 4 holes in cabinet box to bolt the surface or wall mount models on a DoorKing mounting post. Use the hardware that is suppliedwith the mounting post.

Note: A gooseneck mounting post anchored in concrete does not make a good ground.

Mount to a Mounting Post

Use the 4 existing holes in the cabinet box. Run conduit inside or outside of wall or

pilaster if desired. Use appropriate hardware to mount the cabinet (Not

supplied). Be sure that the mounting hardware does not protrude into the cabinet where it could cause a short.

Mount Directly toa Wall or Pilaster

Plastic screw anchors for masonry if

required.(Not supplied)

Conduit shown inside wall

Enclosure

Enclosure Installation1. Route all wiring through conduit or mounting post (not supplied).

2. Clean out the enclosure. Make sure that all dirt, metal and/or wood debris is removed.

4. Re-install components back into the enclosure (Reverse section 1.1.1). Use the wiring schematics in the back of this manual to help re-install the components if needed. DO NOT apply any power at this time.

WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time.

Page 19: Telephone Entry System - Doorking

151800-060 Issued 7-19Version B

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

3 2 1

3 2 1

3 2 1

MASTERCODE

NOHSTONE

OFF

TONEON

HF

NC C

CONTRAST DOORKING 1862-010

16AC16ACBAT NONCCCOMSPKRMICMICGPSWCGNDPHONE

1.5 Memory Chip ReplacementThe Telephone Entry System is shipped with the memory chip already installed in the unit. However, if you need to replace the chip, follow the instructions below.

CAUTION

1862-010 Circuit Board Memory Chip Location

Locked

Release

Power MUST be OFF to the Circuit Board!!

Discharge any static electricity from your hands by touching a proper ground device before installing chip!

Dimple MUST be atthe top of the chip!

1810

-075

sn X

XTH

IS S

IDE

UP

0000

0101

0001

0

1810

-075

sn X

XTH

IS S

IDE

UP

0000

0101

0001

0

LCD Display (Models 1803and 1810 only)

DO NOT install the memory chip with power to the telephone entry system turned ON. Attempting to install the memory chip with power on will irrevocably damage the chip. Memory chip is a static sensitive component. Discharge any static electricity from your hands by touching a proper ground device before touching the control board. Handle the memory chip with care, the pins bend easily.

DO NOT install the memory chip UPSIDE DOWN. this will cause permanent damage to the chip. Be sure that the memory chip is seated correctly in the socket.

Page 20: Telephone Entry System - Doorking

16 1800-060 Issued 7-19Version B

1.6 Postal Lock InstallationAt some locations, such as gated communities, it will be necessary to provide access to the mail carrier so that they can deliver the mail. Mail carrier access will be provided by the installation of an Arrow Postal Lock. This is the same lock that the Post Office uses for gang mailboxes. These locks are not available to the public. The installer or the building owner/manager will have to call the Post Office and arrange for the installation of this lock into the telephone entry system. DoorKing 1803 & 1810 telephone entry systems are designed to accept installation of the postal lock. If you are using the 1808 and need postal service access, use the DoorKing Postal Lock Box sold separately (P/N 1402-080).

Prior to installation of the postal lock, be sure power to the telephone entry system is turned OFF.

1. Remove the hole plug on the faceplate of the telephone entry system.2. Cut the wire tie wrapped around the switch ONLY when installing postal lock.3. Remove the two hex nuts from the postal lock-mounting studs. Mount postal lock on the studs and secure with the hex nuts.

When the lock is installed, the pawl of the lock, in the extended position is depressing the switch. When the mail carrier inserts his key and turns the postal lock, the pawl is withdrawn into the lock and the switch will activate the relay for the programmed strike time, that has been programmed for this feature.Factory default settings for the Postal Lock Switch: After the key has been turned, Relay 1 will activate (section 3.1.7) for One (1) second of strike time (section 3.1.3).Note: The switch input feature (section 3.1.7) is factory set to “activate a relay” and not “dial a phone number”.

Existing postal lock-mounting studs

located inside the faceplate of

the 1803 & 1810.

Existing postal

lock-mounting nuts.

Factory wired

1803 & 1810

Postal Lock

Switch or inside

Postal Lock Box sold

separately.

ComNC

ComNC

Extended Pawl

Withdrawn Pawl

Relay Activates

Blue Wire

N.C.

White Wire

Com

Pawl

POSTAL

LOCK BOX

7788

99

4455

66

1122

33

0012

3

NAME

Jones G341879557032419

Nabur JNeumann JNixon RPatterson FPerez FPetrolli ARay J

640447006745546501330211543987352

Stollach HSynfol ATomlinson LTompson ATompson STyler QWashington GWashington KWent LWhiting MWinston FWyatt J

650791021076100334213229007134609389679211670441

Jones G341879557032419

Nabur JNeumann JNixon RPatterson FPerez FPetrolli ARay J

640447006745546501330211543987352

Stollach HSynfol ATomlinson LTompson ATompson STyler QWashington GWashington KWent LWhiting MWinston FWyatt J

650791021076100334213229007134609389679211670441

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONS

Locate Code Number on Directory.

Press Code Number. If Line is Busy,

Press “#” to Hang UP. Try Again.

Enter on Tone.

1.2.

3.

7788

99

4455

66

1122

33

00

1803Hole Plug1810Hole Plug

1808POSTALLOCK BOX

7788

99

4455

66

1122

33

00

Push Button

Push ButtonTo CallTo Call

Page 21: Telephone Entry System - Doorking

171800-060 Issued 7-19Version B

The tamper switch needs to be connected to a security device or existing security system to comply with the UL 294 standard. Connect the 2 white wires of the Normally Closed gravity activated dry contact tamper switch to whatever security setup you desire. The gravity switch gets activated when the faceplate is opened. Repair and maintenance technicians may need to notify the proper authorities BEFORE opening the entry system faceplate, depending on how your security of this system has been setup.

1.7 UL 294 Compliant Tamper Switch

Possible Security Connections

SecurityCamera

LocalAlarm

System

SeparateAlarmPower

Siren

WarningLight

SeparateSiren

Power

SeparateLight

Power

SeparateCameraPower

ExistingBuilding Alarm

System

TamperSwitch

Gravity Activated(Dry Contact)

WhiteWhite

Note: To comply with UL 294 Standard for Safety, the tamper switch provided in this access control equipment must be set to activate an alarm or alarm signal when tripped. If the tamper switch is NOT connected to activate an alarm or alarm signal, this will void UL 294 certification.

1803

Surface

Mount

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

MASTERCODE

NO

HS

TONEOFF

TONEON

HF

NCC

CONTRASTDOORKING 1862-010

1810

-075

sn X

XTH

IS S

IDE

UP

0000

0101

0001

0

16AC

16AC

NONC

CBAT

COM

SPKR

MIC

MICG

PSW

CGND

PHONE

DOORKINGInglewood, Ca 90301

Model # 1800 Series

Serial #Complies F.C.C. Part 68

F.C.C. Registration #

DUF6VT-12874-OT-T

Ringer Equiv. 0.0A

Jack USOC RJ11C or W

ACCESS CONTROL

SYSTEM UNITS

CONFORMS TO UL STD 294

OUTDOOR USE / WET

D O O R K I N G ® , I N C .MADEINUSA

PART NUMBER

REV

SERIAL NO.

D O O R K I N G ® , I N C .

Mfg. in U.S.A.Access Control Solutions

Since 1948

This product is manufactured under one

or more of the following U. S. Patents.

OTHER PATENTS PENDING

DOORKING INC., INGLEWOOD CA

Patent No.Date

Patent No.Date

Page 22: Telephone Entry System - Doorking

18 1800-060 Issued 7-19Version B

Low Voltage/Communication

Wire Conduit

High VoltagePower Wire(115 V) Conduit

Electrical field from high voltage wires.

6” minimum

Underground Cutaway

SECTION 2 - WIRING

Be sure that you use proper wire that has an insulation rated for an underground environment. All wires should be placed in conduits. Proper pre-planning can greatly ease the installation and wiring of this system. Always check with the local building code to determine the type of wire required in your municipality.DO NOT run high voltage (115 V) power lines and low voltage/communication lines in the same conduit. These should be in separate conduits at least six (6) inches apart. Be sure that all phone line wiring is twisted and completely isolated from ground.

Prior to installing wiring to the telephone entry system, we suggest that you become familiar with the instructions, illustrations, and wiring guidelines in this manual. This will help insure that you installation is performed in an efficient and professional manner.The wiring of the telephone entry panel is an extremely important and integral part of the overall access control system. Use proper wire for the communication line, power wires, and be sure that the system is properly grounded. Check all local building ordinances and building codes prior to installing this system. Be sure your installation is in compliance with local codes.Telcom Access Standards. It is not permissible for customers to use the telcom network lead-in cable to provide the intercom function between the gate and the house. New Zealand Customers: All door and gate entry systems wiring must comply with PTC106: March 2008, Section 9.

WARNING If this telephone entry system is used to control a vehicular gate with an automatic gate operator, the telephone entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that the user cannot come into contact with the gate or gate operator when using this entry system. If this unit has been installed closer to the automated vehicular gate, do not proceed with any wiring until the unit has been moved and re-installed so that it is in compliance with these instructions.

This telephone entry system contains a number of static sensitive components that can be damaged or destroyed by static discharges during installation or use. Discharge any static prior to removing the circuit board from the enclosure by touching a proper ground device.

Use only the supplied transformer (or UL listed equivalent) to power the telephone entry system. DO NOT power any other devices (electric strikes, magnetic locks, lights etc.) from this power transformer.Note: Transformer is not supplied on units sold outside the United States. An Inherently Protected Transformer must be used to power this device. Only use transformer that is listed by a recognized testing laboratory to power the telephone entry system.

“Optional” 12 volt .8 amp hour gel-cell battery (DoorKing P/N 1801-008) can be installed to provide stand-by power in the event of a power outage.

2.1 Wiring Guidelines2.1.1 Power

2.1.2 Wire Runs

Up to 100 feet, use 18 AWG, 600 volt insulated wire.Up to 200 feet, use 16 AWG, 600 volt insulated wire.The importance of proper AWG power wiring cannot be over stressed!

Wire polarity does not matter

Power wires are susceptible to noise and hum pickup; therefore it is preferable that you keep power wire runs as short as possible.

16.5 VAC, 20 VA

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

PERMANENT WIRING MUST BE EMPLOYED AS REQUIRED BY LOCAL ELECTRICAL CODES. ALWAYS ADHERE TO THE LOCAL AND NATIONAL ELECTRICAL CODE SPECIFICATIONS WHEN WIRING THE TELEPHONE ENTRY SYSTEM/ACCESS CONTROLLER AND OTHER ACCESS CONTROL DEVICES.

Do Not Connect To AReceptacle Controlled

By A Switch.

Page 23: Telephone Entry System - Doorking

191800-060 Issued 7-19Version B

The use of surge suppressors can significantly reduce the chance of component failure because of static charges or surges. DoorKing recommends Installing a Phone Line surge suppressor (DoorKing P/N 1877-010 or equivalent) and a Low Voltage surge suppressor (DoorKing P/N 1878-010 or equivalent) to help protect the entry system from power surges.

Proper grounding of this system is a requirement. To be effective, ground connections should be made with a minimum 12 AWG, 600 volt insulated wire to a ground point within 10 feet of the telephone entry system. The ground point must be at an electrical panel, a metallic cold water pipe that runs in the earth, or a stainless steel grounding rod driven at least ten (10) feet into the soil. A mounting post anchored to concrete does NOT make a good ground.

16.5 VAC Transformer

Surge suppressor within 3 ft of ground source.

POWER LINE1878-010

Low voltage surge suppressorwithin 10 ft of entry system.

Some Acceptable Ground Sources

Ground to a metallic cold water pipe.

GroundWire

GroundWire

Ground to an existing electrical system.

ElectricalPanel

Grounding rod 10 feet in soil.

Phone line surge suppressorwithin 10 ft of entry system.

Surge suppressor within 3 ft of ground source.

Phone CompanyPHONE LINE1877-010

2.1.3 Grounding

2.1.4 Surge Suppression

2.1.5 Ferrite FilterThe Telephone Entry System comes with a Ferrite Filter. This will help prevent noise and hum pickup in the phone lines. Install around the 16 VAC power wires on the main terminal #13 and #14.

To install the ferrite filter, release the clip on the side to open the filter, place the wires in the circular core and snap the filter closed.

Power Wires

16AC

1413

1211

109

8

16AC

Main Terminal

NONC

CBAT

COM

Clip Release

Phone Line Surge Suppressor

Low Voltage Surge Suppressor

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

IMPORTANT: Ground wire shown without safety protection for clarity. Make sure ground wire is protected from being touched or electrical shock could occur!

Page 24: Telephone Entry System - Doorking

20 1800-060 Issued 7-19Version B

RING

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

KEYPAD

3 2 1

3 2 1

3 2 1

NOHSTONE

OFF

TONEON

HF

NC C

16AC16ACBAT NC NOCSPKR COMMICGPSWCGNDPHONE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Main Terminal

16 VAC Input Power

20 VA Minim

um16 VAC Input Pow

er

Standby Battery POSITIVE (12 VDC, .7 Ah, SLA) (connect negative to terminal 8)

Relay 1 Normally Open – 30 Volt, 3 Am

p max.

Relay 1 Normally Closed – 30 Volt, 3 Am

p max.

Speaker Output (Purple Wire).

Relay 1 Comm

on

Comm

on for Switch Input 1 term

inal #4, speaker, Standby Battery NEGATIVE

Microphone ground Input (W

hite Wire).

MICM

icrophone Input (Green Wire).

Switch Input 1. A closure betw

een terminals 4 and 8 w

ill cause Relay 1 to activate for theprogram

med strike tim

e or dial a preprogramm

ed phone number – see section 3.1.7.

Postal Switch connection.

Earth Ground Only (See Section 2.1.3). NOT a low voltage com

mon.

Switch Input 2Terminal Non-Removable

Relay 2 TerminalNon-Removable

100 ft. max. w

ith 18 AWG w

ire.200 ft. m

ax. with 16 AW

G wire.

Install ferrite filter on these wires - see section 2.1.5.

Located in the upper left corner of circuit board.

NO NC C

Norm

ally

Ope

n –

30 V

olt,

3 Am

p m

ax.

No

rmal

ly C

lose

d –

30 V

olt,

3 Am

p m

ax.

C

omm

on –

30

Volt,

3 A

mp

max

.

A closure between these terminals will cause Relay 2 to activate for the programmed strike time or dial a preprogrammed phone number (see section 3.1.7).

21

2.2 Terminal Descriptions

800 ft. max. w

ith 24 AWG w

ire.1600 ft. m

ax. with 22 AW

G wire.

(Wiring M

UST be twisted and isolated from

the ground)

FerriteFilter

Phone Line Connection Ring

Phone Line Connection Tip

UL 294TamperSwitchLocated undermicrophone board(See Section 1.7).

Do Not Connect Power To A Receptacle

Controlled By A Switch.

Page 25: Telephone Entry System - Doorking

211800-060 Issued 7-19Version B

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

3 2 1

3 2 1

3 2 1

MASTERCODE

NOHSTONE

OFF

TONEON

HF

NC C

CONTRAST DOORKING 1862-010

16AC16ACBAT NONCCCOMSPKRMICMICGPSWCGNDPHONE

1810

-075

sn X

XTH

IS S

IDE

UP

0000

0101

0001

0

2.3 Telephone Entry System Wiring and Adjustments

Door ControlGate Control

Main Terminal

Door Locks

Gate Operator

Power for electric strike or magnetic lock is NOT provided by the system. Use separate UL listed power supply.

Magnetic lock is wired to the Normally Closed (NC) relay input.

Electric strike is wired to Normally Open (NO) relay input.

Gate Operator is wired to

Normally Open (NO) relay

input.

Lock PowerUL listed

To a Relay InputTo aRelay Input

DoorLock

Wiring MUST be twisted and completely isolated from ground. See section 2.1.4.

“PSW” Switch Input 1 -See section 1.6 for Postal lock connection.

A switch closure across these terminals activates Relay 1 for its programmed strike time or dials a

preprogrammed phone number.See section 3.1.7 Switch Input Feature.

Switch Input 2 -A switch closure across these terminals activates Relay 2 for its

programmed strike time or dials a preprogrammed phone number.See section 3.1.7 Switch Input Feature.

“PHONE”

“PHONE”

Central OfficePhone Line Input

See Section 2.4

“CGND”Earth GroundSee section 2.1.3.

Black (Neg)White

Blue Red (Pos)

“NO” - Normally Open (NO)

“NC” - Normally Closed (NC)“C” - Common (C)

Relay Input 2“C” - Common (C) “NC” - Normally Closed (NC)“NO” - Normally Open (NO)

Relay Input 1

Wire Size Distance24 AWG22 AWG

Up to 800 ftUp to 1600 ft

LCD Display Contrast AdjustSee 2.3.3

Master Code SwitchSee 2.3.4

Speaker AdjustSee 2.3.1

Ring Pin JumperSee 2.3.5

Tone On/Off JumperSee 2.3.1

Handset/ Hands Free JumperSee 2.3.6

Microphone AdjustSee 2.3.1

Click Sensitivity AdjustSee 2.3.2

Feedback AdjustSee 2.3.1

Factory wired on1803 & 1810 ONLY.

Ring

Tip

LCD Display(1803 & 1810 only)

Com

NC

POSTAL

LOCK BOX

External Postal lock connection

(Optional).

Type of wiring to be used on ALLexternal devices:

A) Type CL2, CL2P, CL2R, or CL2X.

B) Other cable with equivalent orbetter electrical, mechanical, andflammability ratings.

UL 294 TamperSwitch

Note: Located undermicrophone board(See Section 1.7).

“BAT” & “COM” - 12 VDC, .7 Ah, SLA Standby Battery InputBattery must power system at least 30 minutes to comply with Canadian certification (Battery not supplied).

16.5 VAC, 20 VA power.See section 2.1.1

16.5 VAC20 VA

Wire Size Distance18 AWG16 AWG

Up to 100 ftUp to 200 ft

Do Not Connect Power To A Receptacle Controlled

By A ON/OFF Switch.

Ferrite FilterSee 2.1.5 Power

Input

Page 26: Telephone Entry System - Doorking

22 1800-060 Issued 7-19Version B

Speaker volume, microphone volume and feedback ALL interact with each other to affect the audio performance of the system.

1. Locate the speaker volume, microphone volume and feedback adjustments on circuit board (see previous page).2. Set the speaker volume: Place a phone call from the telephone entry system to a resident. While they are talking, adjust the speaker volume potentiometer for adequate sound. To increase the volume rotate the potentiometer clockwise, to decrease the volume rotate the potentiometer counter clockwise. See Feedback adjustment below.3. Set the microphone volume: Place a phone call from the telephone entry system to a resident. Talk to the resident in a normal voice while adjusting the microphone volume potentiometer. Ask the resident to let you know when the sound in their telephone is adequate. To increase the volume rotate the potentiometer clockwise, to decrease the volume rotate the potentiometer counter clockwise. See Feedback adjustment below.4. Set the feedback: Place a phone call from the telephone entry system to a resident. After they answer, ask the resident to remain silent.5. While the resident is still on the line, remove the jumper from the TONE OFF terminals on the circuit board and place it on the TONE ON terminals. A tone will be heard in the speaker.6. Rotate the feedback potentiometer clockwise, and then counter clockwise. When the tone from the speaker is minimum, this is the correct adjustment.7. Jumper MUST be moved back to the TONE OFF terminals when complete.8. High microphone and speaker volume levels may cause feedback. It may be necessary to reduce the speaker volume if the microphone volume is set too high. Likewise, it may be necessary to reduce the microphone volume if the speaker volume is set too high.

3 2 1

MIC VOL

3 2 1 SPKVOL

FEEDBACK

3 2 1

2.3.2 Click Sensitivity - Use for Rotary-Dial Phones ONLY1. Locate the click sensitivity adjustment on circuit board (see previous page).2. If rotary dial phones are NOT used, set the click sensitivity to FULL counter-clockwise to disable this feature. If rotary dial phones are in use, proceed to step 3.3. Place a phone call from the telephone entry system to a resident with a rotary dial type phone. After they answer, ask the resident to dial 9 while you adjust the click sensitivity potentiometer (the resident may have to dial 9 several times for you to obtain the correct adjustment). When the door or gate opens, this is the correct adjustment for the click sensitivity.4. Note: Adjusting the click sensitivity too high (potentiometer fully clockwise) could cause the system to respond to loud noises while it is in use. If this happens, rotate the click sensitivity potentiometer counter clockwise 1/8 turn and re-test the system. You may have to perform this step several times to find the correct adjustment.

CLCKSENSE

LCD display is adjusted at the factory and should NOT need to be re-adjusted. If it does, Let the system run for at least 10-minutes before making any display contrast adjustments.

2.3.3 LCD Display Contrast for 1803 & 1810

1. Locate the contrast adjustment (see previous page).2. Turn the MASTER CODE switch ON. The display will read MST CODE. While the display is lighted, turn the contrast potentiometer clockwise and then counter clockwise until the display is satisfactory.3. MASTER CODE switch MUST be turned OFF when finished.Note: Approximately 30 seconds after the master code switch is turned ON, the system will signal a long tone. This is normal and can be ignored. After the master code switch is turned OFF, the display will read MST CODE for approximately 30 seconds.

CONTRAST

3 1

2.3.1 Speaker Volume, Microphone and Feedback

ON

OFF

MASTER

CODE

TONEON TONE

OFF

Page 27: Telephone Entry System - Doorking

231800-060 Issued 7-19Version B

2.3.4 Master Code SwitchThe master code switch MUST be kept in the OFF position for normal operation. Turn the master code switch ON when programming the system’s master code. See section 3.1.1 to program the system’s master code. If the master code switch is turned ON and a new master code is NOT entered, the system will sound a long tone after approximately 30 seconds. This tone will continue every 30 seconds until a new master code is entered, or until the switch is turned off. After the switch is turned off, the LCD display on 1803 & 1810 models will remain lit for approximately 30 seconds, and then will turn off.

Note: Master code switch is turned ON when adjusting the LCD display on 1803 & 1810 models, see section 2.3.3 for more information.

ON

OFF

MASTER

CODE

2.3.6 Hands Free – Hand Set Jumper

For Hands Free (HF) operation, the jumper is set in the right position from the factory. For a system with a Hand Set (HS),the jumper is set in the left position from the factory. An optional handset kit (P/N 1807-012) is available for the 1803 and 1810 models ONLY.

DO NOT place jumpers on both the HS and HF pins at the same time.

HFHS

HFHS

2.3.5 Ring Pin Jumper

The ring pin jumper is labeled RING on the control board. This jumper MUST be installed to allow the system to ALWAYS answer the calls placed to it. If remote programming or remote relay operation is to be used, the jumper MUST be installed on the pins. Removing the jumper will cause the system to NEVER answer calls placed to it.

RING

RING

Always Answer Calls

Never Answer Calls

Optional handsetjumper position.

SURFACE MountSURFACE MountFLUSH MountFLUSH Mount

1810 with Hand Set1803 with Hand Set

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

TELEPHONE ENTRY SYSTEM

OPERATING INSTRUCTIONSLocate Code Number on Directory.Press Code Number. If Line is Busy,Press “#” to Hang UP. Try Again.Enter on Tone.

1.2.

3.

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONSLocate Code Number on Directory.Press Code Number. If Line is Busy,Press “#” to Hang UP. Try Again.Enter on Tone.

1.2.

3.

TELEPHONE ENTRY SYSTEM

77 88 99

44 55 66

11 22 33

00

77 88 99

44 55 66

11 22 33

00

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

3 2 1

3 2 1

3 2 1

MASTERCODE

NOHSTONE

OFF

TONEON

HF

NC C

CONTRAST DOORKING 1862-010

16AC16ACBAT NONCCCOMSPKRMICMICGPSWCGNDPHONE

Page 28: Telephone Entry System - Doorking

24 1800-060 Issued 7-19Version B

DoorKing VoIP Internet Connection

2.4 Phone (Voice) Connection OptionsThere are THREE different ways (Cellular, VoIP or Telephone Line) to connect the telephone entry system for voice communication. The method that you choose is dependent on the type of connection available at the entry system.

See instruction sheet that comes with VOICE ONLY

cellular system kit for further information on wiring and

online registration.

Requires DKS VOICE ONLY Cellular System kit (P/N 1801-080). Manage 2 (two) entry systems through DoorKing’s cellular network server where cellular service is available.

Wireless DoorKing Cellular Network Connection - Voice ONLY

DKS Cellular Serverhosted by AT&T cellular network

with DKS OnlineRegistration Completed

DoorKing Cellular service is available for one low monthly fee without any long term contracts.

Cellular service is provided by AT&T 4G LTE where available.

DKS VOICE ONLYCellular System Kit

P/N 1801-080

1

Their are TWO different ways to connect a VoIP box (Voice over Internet Protocol) to your existing internet connection:VoIP Internet Connection - Voice ONLY2

A

System A

“Optional”System B

Requires a DKS VoIP Adapter Kit P/N 1815-568. Works through the internet.

Cat-5

325 ft Max.

DoorKingVoIP AdapterP/N 1815-568

Phone LineVoice ONLY

PhoneLine

VoiceONLY

VoIP Analog Telephone Adapter

PWR

LNK/ACTPhone

DoorKing VoIP service is available for one low monthly fee without any long term contracts.

See instruction sheet that comes with VoIP Adapter for further information on wiring and online registration.

Third Party VoIP Internet ConnectionBRequires a Third Party VoIP Adapter (most VoIP adapters will work). Works through the internet.

Cat-5Phone LineVoice ONLY

See instruction sheet that comes with third party VoIP Adapter for further information on wiring and online registration.

Your ChosenVoIP Adapter

Select you own VoIP service.

Internet

Your Router

Your Router

Note: Cellular communication may not allow off-site programming from a phone depending on the clarity of the DTMF tones(Dual-Tone Multi-Frequency) the entry system is receiving fromthe phone.

Note: VoIP communication may not allow off-site programming from a phone depending on the clarity of the DTMF tones(Dual-Tone Multi-Frequency) the entry system is receiving from the phone.

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

77 88 99

44 55 66

11 22 33

00

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONSLocate Code Number on Directory.Press Code Number. If Line is Busy,Press “#” to Hang UP. Try Again.Enter on Tone.

1.2.

3.

TELEPHONE ENTRY SYSTEM

77 88 99

44 55 66

11 22 33

00

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONSLocate Code Number on Directory.Press Code Number. If Line is Busy,Press “#” to Hang UP. Try Again.Enter on Tone.

1.2.

3.

TELEPHONE ENTRY SYSTEM

Page 29: Telephone Entry System - Doorking

251800-060 Issued 7-19Version B

HARDwired Telephone Line Connection - Voice ONLY

User supplied telephone line for Voice Connection.

3

You are responsible for the telephone line charges connected to the entry system.

Phone LineVoice ONLY

Telephone Line PreparationOrder your telephone line to be installed at least two weeks prior to the planned telephone entry system installation date. This will assure that a phone line is available when the unit is installed. The telephone company will require the following information from you:

Type: Touch Tone, Loop StartRinger Equivalence: 0.0 AJack Type: RJ11CFCC Registration (US): DUF6VT-12874-OT-TDOC (Canada): 1736 4528 A

• Utilizes the POTS (Plain Old Telephone Service) copper line connected to the telephone entry system.• Voice communication is provided over the POTS line. Programming the entry system using a phone can be preformed over this phone line if desired.• User is responsible for all phone company charges including local and long distance charges, taxes and other fees for this line.Note: Not applicable if Cable or Fiber is a cloud based telephone service.

Caller ID: You may want to order caller ID blocking from the telephone company for the entry system phone line. Without caller ID blocking, residents with the proper phone equipment WILL BE ABLE to identify the telephone number that the telephone entry system is installed on. This may or MAY NOT be desirable.

Call Waiting: Residents may order call waiting from their local telephone company AFTER the system has been installed. They can avoid missing calls coming from the telephone entry system while they are using their phone (No busy signal).

77 88 99

44 55 66

11 22 33

00

NAMEAdams JBernard EBrown LDavis THodges SMiller JSmith KThomas WZimmer R

195246837

CODE

Page 30: Telephone Entry System - Doorking

26 1800-060 Issued 7-19Version B

Operating Instructions1. Locate Code Number On Directory2. Press Code Number. If Line Is Busy, Press Any Button to Hang-Up. Try Again.3. Enter On “OPEN” Display or Tone.

NAME

Adams J

Akins M

Annese J

Anderson H

Applegate B

Austin D

Balsbaugh B

Bass J

Bejar I

Berlin J

Bernard E

Billings L

Broker T

Brose S

Brown J

Brown K

Bryant W

Byron R

Byan G

009

115

352

551

656

078

221

321

249

476

003

112

292

822

491

324

231

332

117

CODE NAME

Byers M

Cardillo P

Carney P

Collins G

Colyer R

Cordula D

Court E

Crains G

Dalton B

Daniels R

Dawls J

DeLahae M

Dill P

Dillon M

Dixon D

Dominick P

Donick P

Donner K

Donter F

807

503

501

404

461

249

772

633

481

104

322

068

888

518

358

467

765

954

992

CODE

NAME

Dorland T

Downward L

Dubreuil M

Dukes D

Enghard L

Ellis W

Farago F

Farrow M

Fernandez S

Garfield S

Garreau J

Gentry M

Gonzalez H

Haberfeld A

Hammer V

Hendrix K

Hird A

Hitch J

Hitch F

Hodges A

Hoover H

Jensen D

Johnson M

Johnson T

Jones A

Jones G

290

152

028

072

828

342

733

441

612

914

542

120

732

186

232

333

835

302

064

005

490

341

879

557

032

419

CODE NAME

Jordan M

Jorden L

Jorgensen B

Klein D

Knoblich B

Lamb B

Land D

Landers S

Langstrom B

Levine D

Lewis B

Lucidi B

Mancini G

Mastin D

Maston F

Mozina J

Mucera J

Mulin B

Nabor K

Nabur J

Neumann J

Nixon R

Patterson F

Perez F

Petrolli A

Ray J

023

562

647

736

408

803

026

996

338

476

101

069

247

122

040

640

447

006

745

546

501

330

211

543

987

352

CODE NAME

Reese D

Reiger B

Remington S

Ressegieu R

Rollins A

Schuster S

Seeley J

Selleck H

Shaer R

Shank D

Simons L

Smith J

Somach H

Steele F

Stollach H

Synfol A

Tomlinson L

Tompson A

Tompson S

Tyler Q

Washington G

Washington K

Went L

Whiting M

Winston F

Wyatt J

081

148

887

063

883

551

731

435

055

082

650

791

021

076

100

334

213

229

007

134

609

389

679

211

670

441

CODE

77 88 99

44 55 66

11 22 33

00

? ? ? ?

SECTION 3 - PROGRAMMINGWe strongly suggest that you read these programming instructions in their entirety before beginning any programming of this telephone entry system.

DoorKing’s 1803/1808/1810 Telephone Entry Systems can be programmed from the keypad (Recommended) on the front of the phone system, or remotely from an off premise location using a touch tone telephone. When programming from an off site location with a touch-tone telephone, the RING jumper MUST be installed on the circuit board (see 2.3.5). We recommend that you do not attempt programming from an off site location until you become familiar with these programming instructions.

Follow the programming instructions as described in each section of this manual. The system will prompt you with short (beep) tones when programming steps have been followed correctly and with a long tone (beeeeeep) when the programming step is ended. The LCD display on 1803 & 1810 models will prompt you for information that you will need to enter.

When each programming step is performed correctly, a short tone (beep) will be heard. When the programming session is ended, a long tone (beeeeeep) will be heard. The amount of telephone numbers that can be programmed into the standard system is 600. The memory size determines the number of four-digit entry codes (memory size + 12) that can be programmed into the system. Five-digit entry codes are limited to six.

Programming from the Keypad

Follow these steps when programming the system from an offsite location (remote). You MUST use a touch-tone telephone and the RING jumper MUST be installed to perform off site (remote) programming.

Programming from an Offsite Location

3.1 General Programming

Programming Notes

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

3 2 1

3 2 1

3 2 1

MASTERCODE

NOHSTONE

OFF

TONEON

HF

NC C

CONTRAST DOORKING 1862-010

16AC16ACBAT NONCCCOMSPKRMICMICGPSWCGNDPHONE

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

3 2 1

3 2 1

3 2 1

MASTERCODE

NOHSTONE

OFF

TONEON

HF

NC C

CONTRAST DOORKING 1862-010

16AC16ACBAT NONCCCOMSPKRMICMICGPSWCGNDPHONE

1. Call the telephone number that the entry system is installed on from a touch-tone telephone. The entry system will answer with a one second tone.2. Follow the programming instructions as described in each section of this manual. The system will prompt you with short (beep) tones when programming steps have been followed correctly.3. When complete, hang up. (You cannot use 0 # to end remote programming sessions).

This programming step sets the system MASTER CODE. The master code is the four-digit number required to gain access to the system memory. You need to know the master code prior to performing any of the programming functions on the following pages.Factory setting = NO Factory code set

1. Open the cabinet of the telephone entry system and turn the master code switch ON.

2. Choose and enter a four-digit master code then press (beep).

3. Turn the master code switch OFF and close the cabinet.

3.1.1 Master Code

ON

OFF

MASTER

CODE

Important Note: There is no way of retrieving the master code after it has been programmed in.If you forget it, you will have to program in a new one but all other previously programmed information will remain intact. Use log tables in back of manual to record your new master code. Keep it secure!

IMPORTANT: Cellular or VoIP communication may not allow off-site programming from a phone depending on the clarity of the DTMF tones (Dual-Tone Multi-Frequency)the entry system is receiving from the phone. RING

LCDScreen

TIP: LCD sceen on a phonewill make programmingMUCH easier.

“Beep”

Page 31: Telephone Entry System - Doorking

271800-060 Issued 7-19Version B

Section 3.3 Entry Code Programming

3.3.13.3.23.3.33.3.43.3.53.3.63.3.73.3.83.3.9

383838383939393939

* 02

* 14

* 00

* 12

* 19

* 09

* 10

* 11

* 13

9999

9999

Programming Four-Digit Entry CodeDelete Individual Four-Digit Entry CodeDelete ALL Four-Digit Entry Codes CAUTIONFour-Digit Entry Code Divide Number to Activate RelaysFour-Digit Entry Code (Reverse Relay Activation ONLY)Programming Five-Digit Entry CodeDelete Individual Five-Digit Entry CodeDelete ALL Five-Digit Entry Codes CAUTIONFive-Digit Entry Code Divide Number to Activate Relays

Page # Factory Setting

Overview for System Programming

Section Command

NO Factory setting0 (single)

Relay 1= 01 (1 sec)Relay 2= 01 (1 sec)

1 (tone ON)060 (60 sec)

Relay 1= 9 8 7 6Relay 2= 5 4 3 20 (relays activate)

02 (two rings)

0 (hang-up)0 (all numbers)

1-relays hang-up1 (hang-up after

5 sec of dial-tone)

Master CodeSingle or Multiple SystemsRelay Strike Time

“Tone Open” Sound ON or OFFTalk TimeTone Open Numbers

Programming Switch Input 1 and Switch Input 2Number of Rings Before Telephone Entry System will AnswerPBX Line Access Code ProgrammingStar Key (*) FunctionKeypad Function (DTMF Programming)System to Stay On-Line or Hang-Up after Touch-Tone Number PressedAutomatic Hang-Up Function

Section 3.1 General Programming

3.1.13.1.23.1.3

3.1.43.1.53.1.6

3.1.73.1.83.1.93.1.103.1.113.1.123.1.13

262828

282829

29293030303031

* 04

* 03

* 17

* 08

* 05

* 23

* 18

* 21

* 27

* 26

* 28

* 40

MasterSwitch ON

Programming Time ClockAutomatic Relay Activation Time ZonesFour-Digit Entry Codes Time ZoneFive-Digit Entry Codes Time Zone“Flash Entry Codes” Active for ONE-DAY ONLY

Section 3.4 Time Functions Programming

3.4.13.4.23.4.33.4.43.4.5

4040414242

* 33

* 35

* 36

* 37

* 15

Section 3.2 Directory Code and Phone Number Programming

3 (3 digits)0 (0 sec)

0 (No)1 (Yes)

32323333343434353536363737

3.2.13.2.23.2.33.2.43.2.53.2.63.2.73.2.83.2.93.2.103.2.113.2.123.2.13

* 20

* 42

* 01

* 01

* 22

* 25

* 06

* 44

* 45

* 01

* 24

* 41

* 01

Programming the Directory Code Length# Key - Insert an Amount of “Pause Time” Between Phone Number DigitsProgramming Phone Numbers - Up to 16-DigitsDeleting Individual Phone NumberDeleting ALL Phone Numbers CAUTIONDisplay / DELETE Phone Numbers with UNKNOWN Directory CodesDisplay Phone Numbers with KNOWN Directory Codes 7-Digit Phone Number Capability CAUTION 16-Digit Phone Number Capability CAUTION Programming 7-Digit Phone Numbers Programming Area Codes (Area Code Reference Numbers) Programming Phone Numbers WITH Area Code Reference Numbers Deleting Individual 7-Digit Phone Number

7-Di

git P

hone

#- L

imite

d Us

e - These

sections are NOT used for Factory Set

16-DigitPhone Number Programming

Page 32: Telephone Entry System - Doorking

28 1800-060 Issued 7-19Version B

0

? ? ? ?80

0

0

1

? ? ? ?71

? ? ? ?30

0

1 2

1. Press and enter your four-digit MASTER CODE (beep).

2. Press (beep) for a single system, OR (beep) for multiple systems.

3. Press together to end this programming sequence (beeeeeep).0

0 1

40 ? ? ? ?

0

This program sequence sets the telephone entry system to operate as a single unit on the phone line, or to share the phone line with other units. If multiple systems are sharing the same phone line, then each one must be set as a “multiple system” and each must have a unique master code.Factory setting = 0 (Single System)

3.1.2 Single or Multiple Systems

These steps will program Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4 second (enter 00 in step 3) up to 99 seconds by entering the desired time in seconds.Factory setting for relay strike times are: Relay 1 = 01 (1 sec), Relay 2 = 01 (1 sec).

3.1.3 Relay Strike Time

1. Press and enter your four-digit MASTER CODE (beep).

2. Press (beep) to set Relay 1, OR (beep) to set Relay 2 strike time.

3. Enter the two-digit strike time in seconds (00-99), then press (beep).

(Example: 1/4 second - enter 00, 1 second - enter 01 etc.)

4. Repeat steps 2 and 3 to set other relay strike time.

5. Press together to end this programming sequence (beeeeeep).

Important Note: If you make a mistake while programming, press keys at the same time

to escape from programming no matter how much has been completed, then begin again at step 1.

The following programming sequence turns the “Tone Open” sound either On or Off (when the relays activate). This feature is available on Rev L boards or higher. See 3.1.6 for information about “Tone Open” numbers feature.Factory setting = 1 (tone ON)

3.1.4 “Tone Open” Sound ON or OFF

1. Press and enter your four-digit MASTER CODE (beep).

The 1803 & 1810 LCD display will read: 1=Y 0=N

2. Enter for YES - tone will sound or for NO - tone will not sound, then press (beep).

3. Press together to end this programming sequence (beeeeeep).

This programming sequence sets the maximum time allowed for conversation when the entry system places a call to the resident. The talk time can be set from 1 second up to 255 seconds (4 minutes, 15 seconds) and is entered as a three-digit number in step 3. The talk time set here DOES NOT affect the telephone numbers that are programmed under directory codes 0, 00, 000, 0000 and 1, 01, 001, 0001. The talk time for these two directory code sets are factory set to the maximum. Phone numbers programmed under these directory codes should be reserved for management or emergency phone numbers that generally require longer conversations.Factory setting for talk time = 060 (60 seconds).

3.1.5 Talk Time

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the three-digit talk time in seconds (001-255), then press (beep).

(Example: 1 second - enter 001, 20 seconds - enter 020 etc.)

3. Press together to end this programming sequence (beeeeeep).

Page 33: Telephone Entry System - Doorking

291800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter a two-digit number of rings, then press (beep).

3. Press together to end this programming sequence (beeeeeep).

1. Press and enter your four-digit MASTER CODE (beep).

2. Press (beep) to set Switch Input 1, OR (beep) to set Switch Input 2.

3. Press (beep) to set to activate the relay, OR (beep) to set the switch input to dial-out a preprogrammed phone number.

4. Press together to end this programming sequence (beeeeeep).

? ? ? ?81

0

1. Press and enter your four-digit MASTER CODE (beep).

2. Press (beep) to set Relay 1, OR (beep) to set Relay 2.

3. Enter the four-digit tone open number code, then press (beep).

(Example: If you want a relay to have a momentary activation function ONLY, and you want that relay to momentary activate when the number 9 is pressed, enter 9 # # #. If a function is not desired, enter # in place of a number. DO NOT duplicate 4-digit tone open numbers, Example: DO NOT set any of Relay 1’s 4-digit tone open numbers to the same number - 9879.)

4. Repeat steps 2 and 3 to set other relay tone open numbers.

5. Press together to end this programming sequence (beeeeeep).0

0

0

? ? ? ?

1 2

1

1

2

50

These steps will program the tone open numbers for Relays 1 and 2. You will need to enter a four-digit number (see chart below) to set the relay functions. If a function is not desired, enter # in place of a number.Fill out log table in back of this manual for desired tone open numbers. Factory setting is: Relay 1 = 9876, Relay 2 = 5432.

3.1.6 Tone Open Numbers

1st Digit2nd Digit3rd Digit4th Digit

Relay 1- 9Relay 1- 8Relay 1- 7Relay 1- 6

Relay 2- 5Relay 2- 4Relay 2- 3Relay 2- 2

Momentary activation. Relay will activate for the programmed strike time (3.1.3).Relay hold. Relay will activate and remain activated until commanded to release.Relay release. Deactivates the relay hold command.Relay hold 1-hour. Relay will activate for 1-hour and then will automatically deactivate itself.

4-Digit Tone Open Number Code Function

Note: Residents will only be able to activate the Momentary activation when using the entry system.

This programming sequence will set how the TWO switch inputs on the telephone entry system control board will operate. Switch input 1 is labeled PSW (postal switch) and is found on terminal 4 of the main terminal strip. Switch input 2 is a two terminal auxiliary input located on the upper left hand corner of the control board. These switch inputs can be programmed to activate their respective relays (switch 1 - relay 1, switch 2 - relay 2). They can also be programmed so that switch 1 dials out the phone number programmed in directory code 0, 00, 000, or 0000, and switch 2 dials out the phone number programmed in directory code 1, 01, 001, or 0001. Each switch is programmed independently.Factory setting = Switch input 1 = 0 (relay 1 activates), Switch input 2 = 0 (relay 2 activates).

3.1.7 Programming Switch Input 1 and Switch Input 2

?? ?? ?? ??33DEFDEF

22ABCABC

This programming sequence sets the number of rings to allow before the telephone entry system answers a call placed to it. This programming sequence does not affect the number of times that a resident’s telephone will ring when a call is placed from the entry system to the resident.Factory setting = 02 (two rings).

3.1.8 Number of Rings Before Telephone Entry System will Answer

? ? ? ?32

Page 34: Telephone Entry System - Doorking

30 1800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. Press (beep) for relay 1, OR (beep) for relay 2.

3. Press (beep) to keep the system on-line, OR (beep) to make it hang up.

4. Repeat steps 2 and 3 to program other relay.

5. Press together to end this programming sequence (beeeeeep).

1

0 1

2

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the single-digit desired key number, then press (beep).

3. Press (beep) for hang-up, OR (beep) for touch-tone.

4. Repeat steps 2 and 3 to program other keys.

3. Press together to end this programming sequence (beeeeeep).

? ? ? ?82

0 1

? ? ? ?62

1. Press and enter your four-digit MASTER CODE (beep).

2. Press (beep) for hang-up, OR (beep) for touch-tone.

3. Press together to end this programming sequence (beeeeeep).

? ? ? ?72

3.1.10 Star Key Function

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the single-digit line access code number, then press (beep).

3. Press together to end this programming sequence (beeeeeep).

Note: To change a line access number, enter the correct number in step 2. To delete a line access number, enter in step 2.

0

0

0

0

? ? ? ?12

If the telephone entry system is connected to a PBX telephone system rather than a dedicated C.O. line, you may need to set the unit to dial a line access code prior to dialing the resident phone number. Typically, the line access code is “9”, but check with the PBX system administrator to be sure.

3.1.9 PBX Line Access Code Programming

This programming sequence sets the function of the key on the keypad during conversation. This key can be set to hang-up the entry system when pressed during conversation, or it can be programmed to touch-tone out during conversation.Factory setting = 0 (hang-up).

00OPEROPER

11SPSP

This programming sequence sets the function of the 0 through 9 and the *, # keys on the keypad during conversation. The keys can be set to hang-up the entry system when they are pressed during conversation, or they can be programmed to DTMF tone out during conversation. The later may be desirable if the entry system is used with an auto-attendant type telephone system where the caller is prompted to enter numbers from a touch-tone telephone.TIP: If DTMF tones are required, program the # or * key to hang-up the system.Factory setting = 0 for all numbers (hang-up).

3.1.11 Keypad Function (DTMF Tone Programming)

This programming sequence provides a method for the telephone entry system to remain on-line after a resident has pressed the touch tone number to open the door or gate. Each relay can be set independently to either remain on line or hang up.Factory setting = 1 (hang up after touch tone number pressed) for both relays.

3.1.12 System to Stay On-Line or Hang Up after Touch Tone Number Pressed

0 1

Page 35: Telephone Entry System - Doorking

311800-060 Issued 7-19Version B

? ? ? ?04

03. Press together to end this programming sequence (beeeeeep).

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the single-digit hang-up code desired (0, 1, 2 or 3), then press (beep).

This programming sequence determines when the phone system will automatically hang itself up after a predetermined time of inactivity. You can program the system to not hang-up (0), to hang-up after 5 sec of dial-tone (1), to hang-up after 15 sec of silence (2) or to hang-up after either 5 sec of dial-tone or 15 sec of silence (3).Factory setting = 1 (hang-up after 5 sec of dial-tone).

3.1.13 Automatic Hang-up Function

0123

No hang-up.Hang-up after 5 sec. of dial-tone (Factory setting).Hang-up after 15 sec. of silence.Hang-up after 5 sec. of dial-tone OR 15 sec. of silence.

Hang-up Code Function

Page 36: Telephone Entry System - Doorking

32 1800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the seconds of pause single-digit (0 to 9 seconds), then press (beep).

3. Press together to end this programming sequence (beeeeeep).

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the directory code digit length (1, 2, 3 or 4), then press (beep).

3. Press (beep) to cancel this function, OR (beeeeeep) to confirm the change.

The programming sequence will automatically end itself after pressing . This CANNOT be UNDONE!

? ? ? ?02

? ? ? ?24

101

0

This programming sequence sets the directory code length to 1 - 2 - 3 or 4 digits. If 11 or more resident names or telephone numbers are going to be programmed into the system, the directory code must be at least two-digits. If 101 or more resident names or telephone numbers are going to be programmed, the directory code must be at least three-digits.Factory setting is three (3) digits.

3.2.1 Programming the Directory Code Length

This programming sequence sets an OPTIONAL Pause Time that the # Key will program in if needed when dialing a 16-Digit Phone Number in section 3.2.3. Insert the chosen Pause Time (# Key) between any phone number digits that need a pause when dialing. # Key can be used multiple times when programming a 16-digit phone number.Note: # Key “Pause Time” will NOT function when 7-Digit Phone number programming is used, section 3.2.10.Factory setting is 0 (0 sec).

3.2.2 # Key - Insert an Amount of “Pause Time” Between Phone Number Digits

3.2 Directory Code and Phone Number Programming

CAUTION: After programming this sequence, it is NOT recommended changing the directory code length. Reprogramming this sequence in the future will delete ALL phone numbers and directory codes that have been previously programmed into the system.

Up to 16-Digit Phone Numbers can be programmed into the phone system when using the factory default settings (sections 3.2.1 - 3.2.7). The phone system can store up to 600 Phone Numbers. It has the capability of storing up to 1000 phone numbers. But to do this, it has to use the old software programs, which are much more complex to program don’t offer nearly as many area codes to use. If more than 600 phone numbers are needed, then sections 3.2.8 - 3.2.13 MUST be used with the limitations of the old software but DoorKing DOES NOT RECOMMEND this.

Page 37: Telephone Entry System - Doorking

331800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the directory code (1, 2, 3 or 4 digits, depending on what was programmed in 3.2.1), then press (beep).

3. Press (beep) again. This CANNOT be UNDONE!

4. Repeat steps 2 and 3 to delete additional phone numbers.

5. Press together to end this programming sequence (beeeeeep).

0

0

0

? ? ? ?10

? ? ? ?10

1 9 0 4 3 5 9 6 6 7 9

1. Press and enter your four-digit MASTER CODE (beep).

2. Choose and enter a directory code (1, 2, 3 or 4 digits, depending on what was programmed in 3.2.1), then press (beep).

Note: Use the log tables in back of this manual to keep track of names, phone numbers and directory codes.

3. Enter the phone number (Up to 16-digits, but less digits will be accepted) for the chosen directory code, then press (beep).

Note: Entering the anywhere in the phone number (multiple #’s can be used) will cause the dialing sequence to pause

(1-9 seconds) if necessary, whatever was programmed in section 3.2.2.

In this programming sequence, the directory codes and phone numbers (up to 16 digits) will be programmed into the system. Be sure you have programmed the directory code length that you desire as described in section 3.2.1.Changing the directory code length (Section 3.2.1) AFTER programming the telephone numbers will ERASE ALL the phone numbers and directory codes that have been previously programmed in.If you use directory codes 0, 00, 000, 0000 and/or 1, 01, 001, 0001 remember that the talk time for these directory codes are factory set to the maximum and cannot be changed. Use these directory codes to program management or emergency phone numbers, which generally require longer conversation periods.

Important: The factory default setting is 16-digit phone numbers. Section 3.2.8: *45 7-digit phone numbers MUST NOT have been reprogrammed ON (1 - YES). If it has been, section 3.2.9 *44 16-digit phone numbers MUST be reprogrammed ON (1 - YES) before proceeding and ALL previously programmed phone numbers WILL be eased.

3.2.3 Programming Phone Numbers - Up to 16-Digits

Note: The phone system can be programmed to store up to 1000 phone numbers ONLY when using sections 3.2.8 - 3.2.13 (7-Digit Phoner numbers and area codes) programming, but this requires more programming for each phone number used, setting up individual area code reference numbers etc. and is not recommended.

Example: Phone number 1-904-359-6679 needs to be dialed with a pause after the 1.

600 (Factory Default) 1000 (using sections 3.2.8 - 3.2.13)Max Phone Number Capacity

Important Note: If you make a mistake while programming, press keys at the same time

to escape from programming no matter how much has been completed, then begin again at step 1.

4. Repeat steps 2 and 3 to enter additional directory codes and phone numbers.

5. Press together to end this programming sequence (beeeeeep).

Programming:

This programming sequence is used to delete a SINGLE phone number under a known directory code.Note: This programming will NOT work for 7-Digit Phone Number programming, use section 3.2.13.

3.2.4 Deleting Individual Phone Number

Page 38: Telephone Entry System - Doorking

34 1800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. The first directory code will be displayed on the LCD screen. Press to view the phone number under this directory code. 7-Digit Phone Number Programming ONLY Note: The first directory code will be displayed on the LCD screen. The phone number, area code reference number and area code programmed under this directory code. The telephone number will display for 2 seconds, then the area code reference number and area code will display for 2 seconds. This sequence will repeat itself.

3. Press to go to the next step.

4. Press to move forward to the next directory code, OR press to DELETE the displayed phone number and move

forward to the next directory code. This CANNOT be UNDONE!

After the last phone number is displayed and OR is pressed, this programming sequence will automatically end itself

by a long (beeeeeep) OR you can press TOGETHER to end this programming sequence at ANY time (beeeeeep).

For 1803 & 1810 models ONLY. This program sequence is useful to display phone numbers when you DO NOT KNOW what directory code they have been programmed under. This sequence also gives you the option to delete the phone number after it is displayed.

3.2.6 Display / DELETE Phone Numbers with UNKNOWN Directory Codes

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the known directory code you wish to display the information for (1, 2, 3 or 4 digits, depending on what was

programmed in 3.2.1), then press (beep).

3. The information programmed under the directory code entered in step 2 will appear on the LCD display. If C C C C C C C appears, this indicates that NO phone number has been programmed under the entered directory code.7-Digit Phone Number Programming ONLY Note: The information programmed under the directory code entered in step 2 will appear on the LCD display. The telephone number will display for 2 seconds, then the area code reference number and area code will display for 2 seconds. This sequence will repeat itself. If C C C C C C C appears, this indicates that NO phone number has been programmed under the entered directory code. If the first digit is flashing, this is the area code reference number and indicates that the number displayed is a long distance phone number.

4. To display additional phone numbers press and repeat step 2.

5. Press together to end this programming sequence (beeeeeep).

For 1803 & 1810 models ONLY. Use this programming sequence to display phone numbers programmed under known direc-tory codes, i.e. if you wanted to see what is programmed under directory code 2719 (assuming directory codes have been programmed for four digits in 3.2.1). This programming sequence will NOT ALLOW you to delete phone numbers.

3.2.7 Display Phone Numbers with KNOWN Directory Codes

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter , then press (beep). This CANNOT be UNDONE!

This programming sequence will automatically end itself by a long (beeeeeep).

This programming step deletes ALL phone numbers previously programmed into the system. CAUTION: This programming step CANNOT be UNDONE!

3.2.5 Deleting ALL Phone Numbers

? ? ? ?60

0

0

0

0

? ? ? ?52

? ? ? ?22

9 9 9 9

Page 39: Telephone Entry System - Doorking

351800-060 Issued 7-19Version B

01

? ? ? ?44

01

? ? ? ?54

This programming sequence will change the factory set 16-Digit Phone Number programming to 7-Digit Phone Number programming. DoorKing DOES NOT RECOMMEND using 7-Digit Phone Number programming for a NEW phone entry system.Factory setting is 0 (NO).

7-Digit Phone Number programming sections 3.2.8 - 3.2.13 will ONLY need to be used when more than 600 Phone Numbers are needed (not typical) OR installing an OLD memory chip in a NEW phone entry system (from an old phone system that has previously programmed information on it). DoorKing does not recommend using an old memory chip. Reprogramming the new memory chip with existing information will take some time but will save time when programming and operating the unit in the future.DoorKing DOES NOT RECOMMEND using 7-Digit Phone Number programming for a NEW phone system. It is more complex to program and and limits the features available compared to 16-Digit Phone Number programming.

Section 3.2.1 - “Directory Code Length” MUST be programmed before section 3.2.10 can be programmed.

Section 3.2.2 - “Pause Time” # key will NOT function when programming 7-Digit Phone Numbers.

Section 3.2.4 - “Delete Individual Phone Number” will NOT work for 7-Digit Phone Number programming. Use section 3.2.13.

Sections 3.2.5 - 3.2.7 - “Delete and Display” programming WILL function when using 7-Digit Phone Number programming.

Section 3.2.8 - “7-Digit Phone Number Capability” MUST be programmed to YES before section 3.2.10 can be programmed.

3.2.8 7-Digit Phone Number Capability

7-Digit Phone Number Programming - Limited Use

CAUTION: If 7-digit programming is turned ON (1-YES), All previously programmed phone numbers and directory codes will be ERASED.

1. Press and enter your four-digit MASTER CODE (beep).

2 sec. LCD display on 1803 & 1810 models will read: 7 DIG?.

...then the LCD display will read: 1=Y 0=N.

2. Press (beep) for YES, OR (beep) for NO.

The 1 “YES” LCD display will read: ERASING. This CANNOT be UNDONE! Programming sequence will automatically end itself when finished by a long (beeeeeep).

This programming sequence DOES NOT need to be changed when using 16-Digit Phone Number programming. This ONLY needs to be turned back ON (1-YES) if you want to change 7-Digit Phone Number programming back to 16-Digit Phone Number programming. DoorKing ALWAYS RECOMMENDS using 16-Digit Phone Number programming for a phone entry system. Factory setting is 1 (YES).

3.2.9 16-Digit Phone Number Capability

CAUTION: If this programming is turned back ON (1-YES), All previously programmed phone numbers and directory codes will be ERASED.

1. Press and enter your four-digit MASTER CODE (beep).

2 sec. LCD display on 1803 & 1810 models will read: 16 DIG?.

...then the LCD display will read: 1=Y 0=N.

2. Press (beep) for YES, OR (beep) for NO.

The 1 “YES” LCD display will read: ERASING. This CANNOT be UNDONE! Programming sequence will automatically end itself when finished by a long (beeeeeep).

Page 40: Telephone Entry System - Doorking

36 1800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. Choose and enter a two-digit area code reference number (01 through 15) that will reference area code to be programmed,

then press (beep).

3. Enter the four-digit area code, then press (beep).

For long distance calling requirements: enter 1 and the three-digit area code (example: 1203). For 10-digit calling requirements: enter # and the three-digit area code (example: #203).

4. Repeat steps 2 and 3 to enter additional area codes. Use a different area code reference number for each area code programmed when entering more than one area code (up to 15).

5. Press together to end this programming sequence (beeeeeep).

? ? ? ?42

1. Press and enter your four-digit MASTER CODE (beep).

2. Choose and enter a directory code (1, 2, 3 or 4 digits, depending on what was programmed in 3.2.1), then press (beep).

3. Enter a seven-digit phone number for the chosen directory code, then press (beep).

If the number that you are entering in this step is LESS than seven-digits, enter # in the empty spaces. For example, if the system is connected to a PBX that requires four-digit extension numbers and you want to enter extension 2217, you would

enter this number as: then press (beep).

4. Repeat steps 2 and 3 to enter additional directory codes and phone numbers.

5. Press together to end this programming sequence (beeeeeep).

? ? ? ?10

0

0

2 2 1 7

In this programming sequence, the directory codes and 7-digit phone numbers will be programmed into the system. Be sure you have programmed section 3.2.8 to YES (7-digit capability) and the directory code length that you desire in section 3.2.1. Changing the directory code length AFTER programming the telephone numbers will ERASE ALL the phone numbers and directory codes that have been previously programmed in. To program phone numbers that will be referenced to an area code (long distance calls and 10 digit calling), follow the instructions under 3.2.11 Long Distance Phone Number Programming below. If you use directory codes 0, 00, 000, 0000 and/or 1, 01, 001, 0001 remember that the talk time for these directory codes are factory set to the maximum and cannot be changed. Use these directory codes to program management or emer-gency phone numbers, which generally require longer conversation periods.

3.2.10 Programming 7-Digit Phone Numbers

Up to 15 different area codes can be programmed for any 10-digit or long distance calling requirements and will be referenced as area code reference number 01 through 15. The area codes will be entered as a four-digit number (1 + the three digit area code, example: 1203). If area codes are being programmed to facilitate 10-digit calling requirements, precede the three-digit area code with # (example: #203).

3.2.11 Programming Area Codes (Area Code Reference Numbers)

Note: If this telephone entry system is being used in an area that requires 10-digit dialing, proceed to 3.2.11 and 3.2.12 to program the area code and phone number. DO NOT program 7-digit numbers.

0102030405060708

Area Code Reference Number Area Code Area Code Reference Number Area CodeUse these tables to keep track of area codes programmed in. Complete log table in back of manual when finished.

09101112131415

Page 41: Telephone Entry System - Doorking

371800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the directory code (1, 2, 3 or 4 digits, depending on what was programmed in 3.2.1), then press (beep).

3. Enter , then press (beep). This CANNOT be UNDONE!

4. Repeat steps 2 and 3 to delete additional phone numbers.

5. Press together to end this programming sequence (beeeeeep).

? ? ? ?14

? ? ? ?10

0

0

2 2 1 7

1. Press and enter your four-digit MASTER CODE (beep).

2. Choose and enter a directory code (1, 2, 3 or 4 digits, depending on what was programmed in 3.2.1), then press (beep).

3. Enter the two-digit area code reference number (01 through 15), then press (beep).

See tables on previous page and log tables in back of this manual for area code reference numbers that have been programmed in.

4. Enter a seven-digit phone number for the chosen directory code, then press (beep).

If the number that you are entering in this step is LESS than seven-digits, enter # in the empty spaces. For example, if the system is connected to a PBX that requires four-digit extension numbers and you want to enter extension 2217, you would

enter this number as: then press (beep).

5. Repeat steps 2, 3 and 4 to enter additional long distance phone numbers.

6. Press together to end this programming sequence (beeeeeep).

Program phone numbers that are referenced to an area code (long distance and 10-digit dialing calls). Make sure that the area code(s) have already been programmed with area code reference numbers in previous section 3.2.11. Be sure you have programmed section 3.2.8 to YES (7-digit capability) and the directory code length that you desire in section 3.2.1.

3.2.12 Programming Phone Numbers WITH Area Code Reference Numbers

Note: If long distance or 10-digit dialing is NOT required, program the 7-digit telephone numbers as described in section 3.2.10.

This programming sequence is used to delete a SINGLE phone number under a known directory code using the 7-Digit Phone Number Programming ONLY. Note: Use section 3.2.4 when using factory default 16-Digit Phone Number Programming.

3.2.13 Deleting Individual 7-Digit Phone Number

Page 42: Telephone Entry System - Doorking

38 1800-060 Issued 7-19Version B

The four-digit entry codes can be made to activate either relay 1 or relay 2 by programming a four- digit divide number. Four-digit entry codes equal to or less than the divide number will activate relay 1. Four-digit entry codes greater than the divide number will activate relay 2.TIP: you can make ALL four-digit entry codes (except 0000) activate Relay 2 by programming divide number 0000, or make ALL four-digit entry codes activate Relay 1 by programming divide number 9999.Factory default divide number is 9999 - Activates Relay 1.

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the four-digit divide number, then press (beep).

3. Press together to end this programming sequence (beeeeeep).

1. Press and enter your four-digit MASTER CODE (beep).

2. Press then press (beep).

This programming sequence will automatically end itself by a long (beeeeeep).

This programming step deletes ALL four-digit entry codes that have been programmed into the system. CAUTION: This programming CANNOT be UNDONE!

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the four-digit entry code to be deleted, then press (beep).

3. Repeat step 2 to delete additional entry codes.

4. Press together to end this programming sequence (beeeeeep).

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the four-digit entry code, then press (beep).

3. Repeat step 2 to enter additional entry codes.

4. Press together to end this programming sequence (beeeeeep).

? ? ? ?20

? ? ? ?41

? ? ? ?21

? ? ? ?00

9 9 9 9

0

0

0

3.3.4 Four-Digit Entry Code Divide Number to Activate Relays

3.3.2 Delete Individual Four-Digit Entry Code

3.3.3 Delete ALL Four-Digit Entry Codes

3.3 Entry Code Programming

This programming sequence programs four-digit entry codes into the system memory. The number of four-digit entry codes that can be programmed is the same as the telephone number memory capacity, plus 12. We suggest that all entry codes that are programmed into the system be listed with the names of residents that they have been assigned to (see log tables in back of this manual).Note: Temporary four-digit entry codes can be programmed into system that will only be active for 24 hours. See section 3.4.5 for more information about “Flash entry Codes” if this feature is desired (Time clock must be programed, section 3.4.1).

3.3.1 Programming Four-Digit Entry Code

Page 43: Telephone Entry System - Doorking

391800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the five-digit divide number, then press (beep).

3. Press together to end this programming sequence (beeeeeep).

1. Press and enter your four-digit MASTER CODE (beep).

2. Press then press (beep).

This programming sequence will automatically end itself by a long (beeeeeep).

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the five-digit entry code to be deleted, then press (beep).

3. Repeat step 2 to delete additional entry codes.

4. Press together to end this programming sequence (beeeeeep).

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the five-digit entry code, then press (beep).

3. Repeat step 2 to enter additional entry codes.

4. Press together to end this programming sequence (beeeeeep).

? ? ? ?90

? ? ? ?11

9 9 9 9

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter a single-digit hold code number (1-4:Relay 1, 5-8:Relay 2), then press (beep).

3. Enter a four-digit entry code, then press (beep). Fill in table below and in back of this manual.

4. Repeat steps 2 and 3 to enter additional Hold four-digit entry codes (up to 8 codes total).

5. Press together to end this programming sequence (beeeeeep).

? ? ? ?91

0

0

0

0

This programming sequence programs five-digit entry codes into the system memory. The number of five digit entry codes that can be programmed is limited to six. We suggest that all entry codes that are programmed into the system be listed with the names of residents that they have been assigned to (see log tables in back of this manual).

3.3.6 Programming Five-Digit Entry Code

The five-digit entry codes can be made to activate either relay 1 or relay 2 by programming a five-digit divide number. Five-digit entry codes equal to or less than the divide number will activate relay 1. Five-digit entry codes greater than the divide number will activate relay 2.TIP: you can make ALL five-digit entry codes (except 0000) activate Relay 2 by programming divide number 00000, or make ALL five-digit entry codes activate Relay 1 by programming divide number 99999.Factory default divide number is 99999 - Activates Relay 1.

3.3.9 Five-Digit Entry Code Divide Number to Activate Relays

3.3.7 Delete Individual Five-Digit Entry Code

3.3.8 Delete ALL Five-Digit Entry CodesThis programming step deletes ALL five-digit entry codes that have been programmed into the system. CAUTION: This programming CANNOT be UNDONE!

A four-digit entry code can be programmed to reverse the condition of relay 1 or relay 2 ONLY. If a relay is NOT activated, entering one of these entry codes will activate it and keep it activated (Hold). If a relay is activated, entering one of these entry codes will release it.(4) entry codes can be assigned to each relay using specific Hold Code numbers. DO NOT use existing four-digit entry codes that were programmed in from section 3.4.1. Rev P circuit board or higher ONLY.Hold four-digit entry code will override any hold open sequence that is in progress and close the gate immediately.Hold code numbers 1 through 4 are assigned to Relay 1 ONLY (one four-digit entry code per hold code number).Hold code numbers 5 through 8 are assigned to Relay 2 ONLY (one four-digit entry code per hold code number).

3.3.5 "Hold Four-Digit Entry Codes" - Reverse Relay Activation ONLY

1234

Relay 1 Hold Code Hold Four-Digit Entry Code

5678

Relay 2 Hold Code Hold Four-Digit Entry Code

? ? ? ?01

? ? ? ?31

Page 44: Telephone Entry System - Doorking

40 1800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter a single-digit time zone number (1 or 2 = relay 1, 3 or 4 = relay 2), then press (beep).

3. Press (beep) to turn time zone ON, OR (beep) to turn time zone OFF.

4. Enter the four-digit BEGINNING hour and minutes, then press (beep).

DO NOT use military (24 hour) time format, simply enter the hour (2 digits) and the minutes (2 digits). For example, 8:30 is entered as 0830. AM or PM gets set on the next step.

5. Press (beep) for AM, OR (beep) for PM.

6. Enter the four-digit ENDING hour and minutes, then press (beep).

DO NOT use military (24 hour) time format, simply enter the hour (2 digits) and the minutes (2 digits). For example, 8:30 is entered as 0830. AM or PM gets set on the next step.

7. Press (beep) for AM, OR (beep) for PM.

8. Enter the seven-digit days of the week, then press (beeeeeep). (Sun = 1, Mon = 2, .....Sat = 7)

All seven digits MUST be entered, to skip any days of the week the time zone will NOT be active, enter # in place of a day. Example 1, to have a time zone active on Saturday and Sunday ONLY (Sun = 1, Sat = 7), enter 1 7 # # # # #.Example 2, to have a time zone active on Monday thru Friday ONLY (Mon = 2, Tues = 3, ......Fri = 6), enter 2 3 4 5 6 # #.

9. Repeat steps 2 through 8 to enter additional time zones.

10. Press together to end this programming sequence (beeeeeep).0

? ? ? ?53

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter the four-digit current hour and minutes, then press (beep).

DO NOT use military (24 hour) time format, simply enter the hour (2 digits) and the minutes (2 digits). For example, 8:30 is entered as 0830. AM or PM gets set on the next step.

3. Press (beep) for AM, OR (beep) for PM.

4. Enter the two-digit month, then press (beep).

5. Enter the two-digit day of the month, then press (beep).

6. Enter the two-digit year, then press (beep).

7. Enter the single-digit day of the week (Sun = 1, Mon = 2, .....Sat = 7) then press (beeeeeep).

? ? ? ?33

10

1

1

0

0

10

3.4 Time Functions Programming

This programming sequence programs the calendar chip in the telephone entry system for the current time and date. The calendar chip MUST be programmed if you are going to use any of the time functions available with the entry system.

3.4.1 Programming Time Clock

This program sequence sets up to FOUR time zones to automatically activate and deactivate the relays on the control board.Each relay can be programmed with TWO independent time zones.Time zones 1 and 2 controls Relay 1 operation ONLY.Time zones 3 and 4 controls Relay 2 operation ONLY.Use the chart in the log tables in back of this manual to record the time zones that are programmed. These time zones can be independently turned ON or turned OFF after they have been programmed (see operating instructions 4.2.5 to turn ON or OFF the programmed time zones).

3.4.2 Automatic Relay Activation Time Zones

Page 45: Telephone Entry System - Doorking

411800-060 Issued 7-19Version B

1. Press and enter your four-digit MASTER CODE (beep).

2. Press (beep) to turn time zone ON, OR (beep) to turn time zone OFF.

3. Enter the four-digit BEGINNING hour and minutes, then press (beep).

DO NOT use military (24 hour) time format, simply enter the hour (2 digits) and the minutes (2 digits). For example, 8:30 is entered as 0830. AM or PM gets set on the next step.

4. Press (beep) for AM, OR (beep) for PM.

5. Enter the four-digit ENDING hour and minutes, then press (beep).

DO NOT use military (24 hour) time format, simply enter the hour (2 digits) and the minutes (2 digits). For example, 8:30 is entered as 0830. AM or PM gets set on the next step.

6. Press (beep) for AM, OR (beep) for PM.

7. Enter the seven-digit days of the week, then press (beeeeeep). (Sun = 1, Mon = 2, .....Sat = 7)

All seven digits MUST be entered, to skip any days of the week the time zone will NOT be active, enter # in place of a day. Example 1: to have a time zone active on Saturday and Sunday ONLY (Sun = 1, Sat = 7), enter 1 7 # # # # #.Example 2: to have a time zone active on Monday thru Friday ONLY (Mon = 2, Tues = 3, ......Fri = 6), enter 2 3 4 5 6 # #.

8. Enter the LOWER four-digit entry codes boundary number, then press (beep).

Entry codes LOWER than this number will NOT activate relays when the entry code time zone is ON.

9. Enter the UPPER four-digit entry codes boundary number, then press (beep).

Entry codes HIGHER than this number will NOT activate relays when the entry code time zone is ON.

10. Press together to end this programming sequence (beeeeeep).0

? ? ? ?63

1

0

0

0

1

1

This programming sequence sets up ONE time zone for the FOUR-digit entry codes to activate the system relays. This time zone uses a range of four-digit entry codes (Boundary numbers) and can be programmed for certain days of the week. This time zone can be turned ON and turned OFF after it is programmed (see operating instructions 4.2.4 to turn ON or OFF the programmed entry code time zone).

3.4.3 Four-Digit Entry Codes Time Zone

Page 46: Telephone Entry System - Doorking

42 1800-060 Issued 7-19Version B

? ? ? ?511. Press and enter your four-digit MASTER CODE (beep).

2. Enter a single-digit flash code number (1-8 depending on which relay is to be activated), then press (beep).

3. Enter the two-digit day of the month that the code is to be active, then press (beep).

4. Enter a desired four-digit FLASH ENTRY CODE, then press (beep).

6. Repeat steps 2 through 4 to enter additional desired FLASH ENTRY CODES.

4. Press together to end this programming sequence (beeeeeep).

1. Press and enter your four-digit MASTER CODE (beep).

2. Press (beep) to turn time zone ON, OR (beep) to turn time zone OFF.

3. Enter the four-digit BEGINNING hour and minutes, then press (beep).

DO NOT use military (24 hour) time format, simply enter the hour (2 digits) and the minutes (2 digits). For example, 8:30 is entered as 0830. AM or PM gets set on the next step.

4. Press (beep) for AM, OR (beep) for PM.

5. Enter the four-digit ENDING hour and minutes, then press (beep).

DO NOT use military (24 hour) time format, simply enter the hour (2 digits) and the minutes (2 digits). For example, 8:30 is entered as 0830. AM or PM gets set on the next step.

6. Press (beep) for AM, OR (beep) for PM.

7. Enter the seven-digit days of the week, then press (beeeeeep). (Sun = 1, Mon = 2, .....Sat = 7)

All seven digits MUST be entered, to skip any days of the week the time zone will NOT be active, enter # in place of a day. Example 1: to have a time zone active on Saturday and Sunday ONLY (Sun = 1, Sat = 7), enter 1 7 # # # # #.Example 2: to have a time zone active on Monday thru Friday ONLY (Mon = 2, Tues = 3, ......Fri = 6), enter 2 3 4 5 6 # #.

8. Enter the LOWER five-digit entry codes boundary number, then press (beep).

Entry codes LOWER than this number will NOT activate relays when the entry code time zone is ON.

9. Enter the UPPER five-digit entry codes boundary number, then press (beep).

Entry codes HIGHER than this number will NOT activate relays when the entry code time zone is ON.

10. Press together to end this programming sequence (beeeeeep).0

0

? ? ? ?73

1

0

0

0

1

1

This programming sequence sets up ONE time zone for the FIVE-digit entry codes to activate the system relays. This time zone uses a range of five-digit entry codes (Boundary numbers) and can be programmed for certain days of the week. This time zone can be turned ON and turned OFF after it is programmed (see operating instructions 4.2.4 to turn ON or OFF the programmed entry code time zone).Note: FLASH entry codes can NOT be used with five-digit entry codes.

3.4.4 Five-Digit Entry Codes Time Zone

This programming sequence sets up “Flash Entry Codes”. Flash codes are four-digit entry codes that will operate ONLY ONE TIME on a specific day of the month - they will not operate before or AFTER the programmed day. The flash codes will be valid for a single 24-hour period ONLY. For example, if you program a flash code on July 1st to be active on the 10th, the code will become valid at 12:00 AM on July 10th and expire at 11:59 PM on July 10th. The code will not be valid on August 10th. You can program up to EIGHT flash codes in the system.Flash code numbers 1 through 4 will activate Relay 1 ONLY.Flash code numbers 5 through 8 will activate Relay 2 ONLY.

3.4.5 “Flash Entry Codes” - Active for ONE-DAY ONLY

Page 47: Telephone Entry System - Doorking

431800-060 Issued 7-19Version B

? ? ? ?

? ? ? ? ?

7788

99

4455

66

1122

33

00

NAMEAdams JBernard EBrown LDavis THodges SMiller JSmith KThomas WZimmer R

195246837

CODE

NAMEAdams JBernard EBrown LDavis THodges SMiller JSmith KThomas WZimmer R

195246837

CODE

7788

99

4455

66

1122

33

00Operating Instructions

1. Locate Code Number On Directory

2. Press Code Number. If Line Is Busy, Press Any Button

to Hang-Up. Try Again.

3. Enter On “OPEN” Display or Tone.

NAMEAdams JAkins MAnnese JAnderson HApplegate BAustin DBalsbaugh BBass J

Bejar IBerlin JBernard EBillings LBroker TBrose SBrown JBrown KBryant WByron RByan G

419

Perez FPetrolli ARay J

501330211543987352

Tompson ATompson STyler QWashington GWashington KWent LWhiting MWinston FWyatt J

100334213229007134609389679211670441

Operating Instructions

cate Code Number On Directory

ess Code Number. If Line Is Busy, Press Any Button

Hang-Up. Try Again.

nter On “OPEN” Display or Tone.

JM

e Json Hgate Bn Dbaugh Bs Jar Irlin Jrnard Ellings Lroker TBrose SBrown JBrown KBryant WByron RByan G

419

Perez FPetrolli ARay J

501330211543987352

Tompson ATompson STyler QWashington GWashington KWent LWhiting MWinston FWyatt J

100334213229007134609389679211670441

TELEPHONE ENTRY SYSTEM

MODEL 1803

OPERATING INSTRUCTIONS

Locate Code Number on Directory.

Press Code Number. If Line is Busy,

Press “#” to Hang UP. Try Again.

Enter on Tone.

1.2.

3.

7788

99

4455

66

1122

33

00

SECTION 4 - SYSTEM OPERATING INSTRUCTIONS

Instructions on the faceplate of the unit will instruct guest on the operation of the telephone entry system. Guests will locate a residents name and directory code in a directory associ-ated with the telephone entry system. This may be a letter board type directory, an add-on directory or a built-in directory like that found in the 1810 or 1808 with directory units.When a directory code is entered on the system keypad, the telephone entry system will call the preprogrammed telephone number stored under that directory code. If the line is busy, the system will emit a busy signal. Pressing the hang-up key (any key or the preprogrammed hang-up key) will hang the system up. Guest can then try again. Residents can avoid missing calls from the telephone entry system by ordering call waiting from the local telephone company.The system can be programmed so that the system keypad emits DTMF tones after a connection is made. For example, in a business application, a call from the telephone entry system may be answered by an auto-attendant requesting that you enter a person’s extension number. This is possible with the system provided that it has been programmed to emit DTMF tones once the call is answered.

If management decides to utilize resident entry codes, residents should be instructed to keep their unique code secret. Telling other persons their code or allowing other persons to use their code compromises security and defeats the purpose of the system.

The FOUR and FIVE-digit entry codes will operate either relay 1, relay 2, or they can be programmed so that certain codes will activate only relay 1 while others will activate only relay 2. Both four and five-digit entry codes can be time zone restricted.

4.1 General Instructions

Operating Instructions

Operating Instructions

Directory

Directory

4.1.1 Guest Instructions

When communication is established, the resident has the option of opening the door(s) or gate(s) by pressing the programmed tone open number(s) on their touch tone telephone, or they can deny access to their guest by pressing # on their telephone. If access is granted, the resident will hear a confirmation tone in their handset indicating that the door or gate has opened, then the system will automatically hang up.Residents should be instructed by management to always press the # key on their telephone if they wish to deny a guest access. If a resident hangs up to deny access instead of pressing #, the telephone entry system will remain on line until its programmed talk time expires or until it detects dial tone.Some newer type telephones emit a short tone rather than a continuous tone when their keys are pressed. This may cause the telephone entry system to not respond to the tone open number. If this happens, simply press the tone open number twice in rapid succession to open the door or gate.If a resident is using rotary dial telephone, they will grant access to their guest by dialing 9. To deny access to their guest, residents with rotary phones must simply hang up.

4.1.2 Responding to a Guest Call

4.1.3 Using an Entry Code

1810

FOUR-Digit Entry Code - Press and then enter your four-digit Entry Code

FIVE-Digit Entry Code - Press and then enter your five-digit Entry Code

1803

1808

Page 48: Telephone Entry System - Doorking

44 1800-060 Issued 7-19Version B

4.2 System Administrator

1. Call the telephone number that the entry system is installed on. The system will answer with a short tone (beep heard). Note: the number of rings before the system answers is dependent on the programming in 3.1.8.

2. After the system answers, follow the desired programming steps in Section 3.

3. When complete, hang up. You cannot use 0 # together to end the programming step from a touch-tone telephone.

4.2.1 Remote Programming (Touch-Tone Phone)

1. Call the telephone number that the entry system is installed on. The system will answer with a short tone (beep heard). Note: You must know if the system is on a DKS Cellular, VoIP OR a POTS telephone line. Note: the number of rings before the system answers is dependent on the programming in 3.1.8.

2. Press *16 and enter the four-digit MASTER CODE (beep heard).

3. Press the desired single-digit tone open number (beep heard). Note: Refer to 3.1.5 to determine which tone open features have been programmed, i.e. momentary open, hold open, release, hold open one hour and then release. Refer to 6.1 log table in back of manual to reference specific programming.

4. Hang up.

4.2.2 Remote Relay Activation

1. Call the telephone number that the entry system is installed on. The system will answer with a short tone (beep heard). Note: You must know if the system is on a DKS Cellular, VoIP OR a POTS telephone line. Note: the number of rings before the system answers is dependent on the programming in 3.1.8.

2. Press *16 and enter the four-digit MASTER CODE (beep heard).

3. The system will emit a series of short tones if the relay is in a continuous activation mode. Relay 1 activated: beep - pause - beep - pause . . . Relay 2 activated: beep beep - pause - beep beep - pause . . . Relay 1 & 2 activated: beep beep beep - pause - beep beep beep - pause . . .

4. Press the programmed single-digit tone number to deactivate the relay (beep heard). The system will automatically hang up. Note: the single-digit tone number is dependent on the programming in 3.1.6 (factory defaults: Relay 1 - 7, Relay 2 - 3).

The telephone entry system can be called and a check can be made to determine if any of the relays in the system are in a “Hold Open” mode. This check can be useful if your gate (or door) is held open and you suspect that the telephone entry system relay may be the cause.

4.2.3 Remote Relay Check

The administrator can perform the following operations from a remote location (off-site) using a touch-tone telephone. You must know:

• The phone number of the system. • The system’s four-digit MASTER CODE. • If the system is using DKS Cellular, VoIP or POTS telephone line for communications.

LCDScreen

TIP: LCD sceen on a phone will makeprogramming MUCH easier.IMPORTANT: Cellular or VoIP communication may not allow off-site programming

from a phone depending on the clarity of the DTMF tones (Dual-Tone Multi-Frequency)the entry system is receiving from the phone.

Page 49: Telephone Entry System - Doorking

451800-060 Issued 7-19Version B

1. Call the telephone number that the entry system is installed on. The system will answer with a short tone (beep heard). Note: the number of rings before the system answers is dependent on the programming in section 3.1.8.

2. Press *36 for FOUR-digit entry code time zones, or *37 for FIVE-digit entry code time zones, then enter the four-digit MASTER CODE (beep heard).

3. Press 0 * (beep heard) to turn the time zone OFF, or press 1 * (beep heard) to turn the time zone ON.

3. Hang up the phone or if at the system keypad, press 0 # together (beeeeeep).

1. Call the telephone number that the entry system is installed on. The system will answer with a short tone (beep heard). Note: the number of rings before the system answers is dependent on the programming in section 3.1.8.

2. Press *35 and enter the four-digit MASTER CODE (beep heard).

3. Enter the single-digit time zone number that you want to turn OFF or ON, then press * (beep heard). Note: Refer to section 3.4 to determine which time zones have been programmed into the system or see log tables in back of this manual.

4. Press 0 * (beep heard) to turn the time zone OFF, or press 1 * (beep heard) to turn the time zone ON.

5. Hang up the phone or if at the system keypad, press 0 # together (beeeeeep).

The entry code time zones can be turned OFF (disable) or ON (enable) remotely from a touch-tone telephone at any time without changing the time zone boundaries. To program the time zone boundaries, see sections 3.4.3 and 3.4.4. Entry code time zones can also be turned off or on at the system keypad by skipping step 1 and proceeding directly to step 2 in the sequence below.

The four time zones that automatically activate and deactivate the relays can be turned OFF (disable) or ON (enable) remotely from a touch-tone telephone at any time without changing the time zone programming. To program the automatic relay activa-tion time zones, see section 3.4.2. The four Automatic relay time zones can also be turned off or on at the system keypad by skipping step 1 and proceeding directly to step 2 in the sequence below.

4.2.4 Remote Entry Code Time Zone Enable / Disable

4.2.5 Remote Automatic Relay Time Zone Enable / Disable

4.2 System Administrator ContinuedLCDScreen

TIP: LCD sceen on a phone will makeprogramming MUCH easier.

IMPORTANT: Cellular or VoIP communication may not allow off-site programming from a phone depending on the clarity of the DTMF tones (Dual-Tone Multi-Frequency)the entry system is receiving from the phone.

Page 50: Telephone Entry System - Doorking

46 1800-060 Issued 7-19Version B

If the telephone entry system is going to be connected to a PBX system, you may need to program extension numbers in place of a seven-digit telephone number. To do this, enter the extension number and fill the remaining spaces with the # key in the phone number programming step.For example, if the PBX system uses four-digit extensions and you want to program extension 2217 as a phone number, in step 3, section 3.2.10 press:

3. Enter , then press (beep).

If the PBX system requires you to dial 9 to obtain an outside line, and you want to program some outside line phone numbers in the system, program the number 9 as one of the alternate area codes. In step 3, section 3.2.11 press:

3. Enter , then press (beep). Then program the outside phone number as a long distance number

(section 3.2.12) using the area code reference number used to program 9 as one of the alternate area codes.

If the telephone entry system is installed in an area where the telephone company has instituted 10 digit dialing, simply program the required number of alternate area codes into the system without preceding the area code with the number 1.For example, If 310 is one of the area codes required, in step 3, section 3.2.11 press:

3. Enter , then press (beep). Then program the outside phone number as a long distance number

(section 3.2.12) using the area code reference number used to program 310 as one of the alternate area codes. Program

additional area codes and phone numbers as described in sections 3.2.11 and 3.2.12.

The two switch inputs can be programmed to either activate their respective relay (switch input 1 activates relay 1; switch input 2 activates relay 2) or they can be programmed to call the phone number programmed under the first two directory codes (switch input 1 calls the phone number programmed under directory code 0, 00, 000 or 0000) (switch input 2 calls the phone number programmed under directory code 1, 01, 001 or 0001). Each switch input is programmed independently (3.1.7).Switch 1 input is typically used as the postal switch and is pre-wired and pre-programmed for postal switch operation. We suggest that switch input 1 should be left programmed to activate relay 1 to allow the mail carrier entry.Switch 2 input can be programmed as the application requires. For example, if the telephone entry system is controlling a vehicular gate with relay 1 and a pedestrian gate with relay 2, a postal lock box (DoorKing P/N 1402-080) could be installed at the pedestrian gate for the mail carrier and connected to switch input 2. In this manner, the postal lock box would allow the mail carrier access through the pedestrian gate when it is activated. Another use of switch input 2 is to program the input to call a preprogrammed telephone number instead of activating relay 2. An auxiliary button can be installed and connected to switch input 2 and labeled “assistance”. When the button is pressed, the system will automatically dial the phone number programmed under directory code 1, 01, 001 or 0001.

4.3.1 Switch Input 1 & 2 Operation

The talk time for directory codes 0, 00, 000, 0000 and 1, 01, 001, 0001 is factory set to 4 minutes 15 seconds and cannot be changed. These directory codes should be reserved for use with management or emergency phone numbers that typically require longer talk times. For example, if directory code 000 was programmed to call a management phone number, the system will allow the full 4 minutes and 15 seconds of talk time before automatically ending the call.

4.3.2 Talk Time

More than one telephone entry system can share the same phone line provided that the units have been programmed for multiple systems on the same line (see 3.1.2). When the unit is programmed for multiple systems sharing the same line, it checks the phone line for 48 volts (not busy) before attempting to place a call. If the phone line is in use, the system will emit a busy signal. If two or more systems are sharing the same phone line, it is important that each system be programmed with its own unique master code. When more than one system is on the same phone line, and a call is placed from one of the systems to a resident, only the system that placed the call will respond to any tone open numbers. Do not be concerned that all the units will activate their relay when the resident presses the tone open number.

4.3.3 Phone Line Sharing for Multiple Telephone Entry Systems

4.3 Miscellaneous Operating Instructions

4.3.4 Connection to a PBX using 7-Digit Phone Number Programming ONLY

4.3.5 Areas with 10-digit Dialing using 7-Digit Phone Number Programming ONLY

013

9

7122

Page 51: Telephone Entry System - Doorking

471800-060 Issued 7-19Version B

SECTION 5 - MAINTENANCEThe DoorKing telephone entry system is essentially a maintenance free device. When the unit is properly installed, it should provide years of trouble free service. Maintenance is limited to updating the directory and phone number and/or entry codes when residents move in or out.The faceplate of the unit should be cleaned on a regular basis to keep contaminants in the air from sticking to the surface and possibly causing pitting. When cleaning the faceplate of the system, NEVER use an abrasive cleaner or cloth. Stainless steel cleaner works very well with a soft cloth for systems with a stainless steel faceplate. A clean damp soft cloth should be used to clean gold plated faceplates.

The following items are replaceable and can be ordered from your installing dealer.

Circuit Board Replacement Circuit Board P/N 1862-010 REV O or higher. 8-character LCD display P/N 1890-010.

Keypad Replacement keypad – P/N 1895-017 num only

Transformer Replacement power transformer – 16.5 VAC, 20 VA U.L. Listed DoorKing P/N 1804-060

5.1 Replacement Parts

If problems should develop with your telephone entry system, refer to the troubleshooting table below and on the following pages to try and correct any problems. Our experience has shown that a majority of reported problems are actually program-ming related and can be corrected on site. If problems persist and they cannot be corrected, contact your authorized DoorKing dealer for assistance. Before performing any troubleshooting, check the following:

5.2 Troubleshooting

1. Have a good VOM meter handy to check voltages and continuity.

2. Have a telephone test set (DoorKing P/N 1800-050 or equivalent) to check the telephone line. Noise on the phone line will cause problems with the entry system.

3. Be sure that the entry system case is properly grounded.

4. Be sure that the telephone wires are twisted.

5. A hum on the system indicates that the phone line or 16 VAC power lines may be grounded. Check to be sure that the phone lines or power lines are not shorted to ground.

6. Check the 16 VAC system power. Be sure that the transformer is properly rated (16 VAC, 20 VA). Keep the wire run from the transformer to the entry system as short as possible. Use 16 or 18 AWG, 600 volt insulated wire only. The importance of proper power wiring cannot be over stressed!

7. Isolate the telephone entry system. Disconnect any external devices, such as gate operators, electric strikes, magnetic locks, etc., which may affect the operation of the system.

System emits a long tone and cancels programming.

Keypad is dead.

Symptom Possible Solution(s)

• Wrong master code entered. Start over.• Waiting too long between pushing buttons. Enter information quicker.• Keypad is not plugged into board correctly. Cable points down.• Memory chip is installed upside down (Section 1.5).

Cannot get into programming mode.

• Waiting too long between pushing buttons.• Forgetting to press * first when programming.

• No power. Check for 16.5 VAC input power.• Check that the keypad is properly connected to the circuit board. The cable on the plug points down when connected to the circuit board.

Page 52: Telephone Entry System - Doorking

48 1800-060 Issued 7-19Version B

Rotary dial 9 will not activate relay.

• Adjust click sensitivity (2.3.2).

Symptom Possible Solution(s)

Buzz or noise on the phone line.

• Disconnect the phone line from the system and check it with a handset. If line is noisy, problem is with the phone line and not the entry system.• Check for any shorts to ground behind the circuit board.• Check for pinched wires near the door hinge.• Check for 16-volt power shorted to ground.• Check for phone line shorted to ground.• Check that phone wires are twisted.• Check that the proper type of phone wire was used for an outdoor and / or underground application.• Check that all wires, speaker, keypad, etc. are isolated from ground.• Check that the cabinet is properly grounded. Be sure that case ground (CGND terminal 3) is not used as a low voltage common.• Check for excessive voltage drop on 16 VAC power.

• Feedback improperly adjusted (2.3.1).• Volume is set too high (2.3.1).

Ringing or howling from the speaker.After dial out, dial tone is heard on the speaker.

Door strike locks on.

• Phone line is a rotary-dial line. Have the phone company change it to a touch-tone line.

• Excessive voltage-drop on 16 VAC line.• Using a transformer with too low VA rating.• Relay strike time programmed too long (3.1.3).

• Auto relay time zone enabled. Turn auto relay feature off or reprogram the time zone (5.2.5).• System was given a hold open command. Call the system and press the tone deactivate relay number (4.2.5).

Door strike or gate operator holds open.

Touch-tone 9 will not activate relay.

Postal switch will not activate relay.

Switch input 2 will not activate relay.

FOUR-digit entry codes will not work.

System emits a beep every 30 seconds.LCD is unreadable

Entry system will not answer when called.

Relay activates but gate operator will not open.

Entry codes will not activate relay 1.

• Re-program relay strike time for a longer period (3.1.3).• Check wiring to gate operator.• Check gate operator.

• Ring pin is not installed (2.3.5).• Number of rings to answer is set to high. Reprogram (3.1.8).• Bad phone line or insufficient ring voltage.

• Be sure that the wire-tie has been clipped off the postal switch.• Be sure that the relay has been programmed for postal switch input (3.1.7).

• Reprogram switch input 2 which only activates relay 2 (3.1.7).

• Forgetting to press “#” first.• Entry code is time zone restricted. Reprogram time zone (3.4.2) or disable time zone (4.2.5).• Entry code attempted was a FLASH entry code that is no longer valid (3.4.5).

FIVE-digit entry codes will not work.

• Forgetting to press “#” first.• Entry code is time zone restricted. Reprogram time zone (3.4.2) or disable time zone (4.2.5).

• Re-program relay 1 low and high ranges. FOUR-digit codes (3.3.4), FIVE-digit codes (3.3.9).

• Re-program relay 1 low and high ranges. FOUR-digit codes (3.3.4), FIVE-digit codes (3.3.9).Entry codes will not activate relay 2.

• Adjust contrast. (2.3.3).

• Re-program tone-open number to 9 (3.1.6).• If resident phone emits a short pulse rather than a long tone, press 9 rapidly twice “99”.• Try another phone that is known to work.• Lower speaker volume and re-adjust feedback (2.3.1).

• Master code switch is in the ON position. Turn master code switch OFF (2.3.4).

Page 53: Telephone Entry System - Doorking

491800-060 Issued 7-19Version B

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

3 2 1

3 2 1

3 2 1

MASTERCODE

NOHSTONE

OFF

TONEON

HF

NC C

CONTRAST DOORKING 1862-010

16AC16ACBAT NONCCCOMSPKRMICMICGPSWCGNDPHONE

5.3 Accessories

Wiring Schematic

Microphone1998-010

LED Keypad Light LED Keypad Light

Purple

Blue

White

White

Gray

Red

Orange

Gray

Orange

WhiteGreen

CLCKL

P2 10-Pin Keypad plug positionon circuit board - Red wire left.

Postal LockSwitch (Switch Input 1)Factory wired on1803 & 1810 ONLY.

GreenGround

Phone Line

1810

-075

sn X

XTH

IS S

IDE

UP

0000

0101

0001

0

Surge SuppressorsPhone line suppressor. P/N 1877-010.Low voltage (28 V) suppressor. P/N 1878-010.High voltage (115 V) suppressor. P/N 1879-080.

Mounting Posts & KioskOff-Set pad mount. P/N 1200-036.Standard goose-neck, pad mount. P/N 1200-045.Standard goose-neck, In-ground mount P/N 1200-046.Standard dual-mount. P/N 1200-049.Architectual Off-Set mount. P/N 1200-037 Self-standing Kiosk. P/N 1200-170.

Surface Mount Recess KitUse to recess a surface mount unit into a wall or column.P/N 1803-150.

Flush Mount KitUse to install flush style units into a wall or column. Kit includes rough-in back box and trim-ring. P/N 1814-165 comes with stainless steel trim ring. P/N 1814-166 comes with gold plated trim ring.

Telephone Test SetIncludes clips, cord and carrying case. P/N 1800-050.

DKS Cellular Kit - Voice ONLYEnables the 1800 series system to send and receive voice ONLY to a phone via DKS Cellular network.Voice ONLY - P/N 1801-080

DKS VoIP Adapter KitEnables the 1800 series system to send and receive voice via DKS VoIP over IP. P/N 1815-568

Flush Mount Surface Mounting KitUse to surface mount a flush style unit. P/N 1814-152.

Stainless Steel CaseReplaces the black steel surface mount case on the 1803 and 1810 units with a stainless steel case. P/N 1810-102.

Back-Up Battery12 volt .8 amp hour gel cell provides stand by power during power interruptions. P/N 1801-008.

CCTV Camera KitHigh resolution color camera kit. P/N 1812-145.

Secondary Keypads: Allows remote activation of the system relays by use of the access codes. Does not provide any voice communica-tion to the main unit or to the resident telephone. P/N 1812-082 (surface mount); P/N 1812-197 (flush mount).

LCD Display (Models 1803 and 1810 only)

LED Light Note: NOT available on 1803 or 1810 flush mount.ONLY 1 LED light board on surface mount 1810.

Speaker

Lighted Keypad

GrayOrange

Red Wireon RightSide ofRibbonCable

Whi

te

Whi

te

UL 294Tamper Switch

Page 54: Telephone Entry System - Doorking

50 1800-060 Issued 7-19Version B

Complete the information in the tables on the following pages to maintain a record of the information that has been programmed into the telephone entry system.

6.1 Log Tables

Beginning Time

Ending Time

Days of the Week

Automatic Relay Activation Time Zones (section 3.4.2)

Zone 1 - Relay 1 Zone 2 - Relay 1 Zone 3 - Relay 2 Zone 4 - Relay 2

Momentary Activation

Relay Hold OPEN

Relay RELEASE

Relay Hold OPEN 1 Hour

Factory - 9

Factory - 8

Factory - 7

Factory - 6

Factory - 5

Factory - 4

Factory - 3

Factory - 2

Relay 1 Relay 2Tone Open Numbers

(section 3.1.6)

Switch Input 1-Relay 1 Switch Input 2-Relay 2

Postal Lock Activates (section 3.1.7)

Factory Set

Beginning Time

Ending Time

Days of the Week

Lower Boundary #

Upper Boundary #

FOUR-Digit Entry Code Time Zone (section 3.4.3)

Beginning Time

Ending Time

Days of the Week

Lower Boundary #

Upper Boundary #

FIVE-Digit Entry Code Time Zone (section 3.4.4)

Relay 1 Relay 2

Relay Strike Time (section 3.1.3)Master Code (section 3.1.1)

Factory - 1 sec. Factory - 1 sec.

1st Digit 2nd Digit 3rd Digit 4th Digit

0102030405060708

Area Code Reference Number(section 3.2.11) Area Code

Area Code Reference Number(section 3.2.11) Area Code

09101112131415

Area Code Note: Used for 7-Digit Phone Numbers Programming ONLY.

1234

Relay 1 Hold Code Hold Four-Digit Entry Code

5678

Relay 2 Hold Code Hold Four-Digit Entry Code

(section 3.3.5)

Four-Digit Entry Code Divide Number (section 3.3.4) Five-Digit Entry Code Divide Number (section 3.3.9)

Factory - 9999 Factory - 99999

Page 55: Telephone Entry System - Doorking

511800-060 Issued 7-19Version B

NAME ALT. AREA CODEENTRY CODEDIRECTORY CODEPHONE NUMBERAREA CODE

Residents InformationMake additional copies of this table as needed.Alternate Area Code may be needed when using 7-Digit Phone Numbers Programming ONLY, see sections 4.3.4 and 4.3.5 for more info.

Page 56: Telephone Entry System - Doorking

52 1800-060 Issued 7-19Version B

NAME ALT. AREA CODEENTRY CODEDIRECTORY CODEPHONE NUMBERAREA CODE

Residents InformationMake additional copies of this table as needed.Alternate Area Code may be needed when using 7-Digit Phone Numbers Programming ONLY, see sections 4.3.4 and 4.3.5 for more info.

Page 57: Telephone Entry System - Doorking

531800-060 Issued 7-19Version B

Guest Communication: Your name (or apartment number) and telephone number have been programmed into the DoorKing telephone entry system under a specific DIRECTORY CODE. This directory code can be from 1 to 4 digits long. When a guest comes to visit you, they will look up your name in a resident directory (located on a separate printed directory to provide guests with the resident directory information). Your DIRECTORY CODE will be shown next to your name. Your guest will enter this code on the telephone entry system keypad that will place a call to your home (If your guest already knows YOUR specific directory code, they can simply enter the code on the keypad without having to look up your name in the resident directory). A guest CANNOT enter your telephone number on the keypad, it MUST be the DIRECTORY CODE ONLY!

Granting or Denying Access to your Guest: Once you have answered the phone call and you have identified your guest, you have the choice to either grant access or deny access to your guest.

Touch-Tone Phones ONLY.To GRANT ACCESS to your guest, press _____ on your touch‐tone telephone. The telephone entry system will respond with a confirmation tone indicating that the door or gate is opening and will automatically disconnect itself. Some newer telephones emit a very short duration tone when the number is pressed. If your telephone does this, you may have to press the “GRANT ACCESS NUMBER” twice in rapid succession to open the door or gate.

To DENY ACCESS to your guest, press the “#” key on your touch‐tone telephone.

Rotary-Dial Phones ONLY.To GRANT ACCESS to your guest, dial “9”.

To DENY ACCESS to your guest, hang-up your phone.

Call Waiting: If you are on your telephone when a guest tries to contact you from the telephone entry system, they will hear a busy signal and will have to wait for you to end your call before they can contact you. To eliminate this problem, you can order call waiting from your local telephone company.

Privacy: If you DO NOT want your name and/or apartment number listed in the resident directory, inform the system administrator of this. If you choose this option, you will need to inform your guest what YOUR directory code is, otherwise there will be NO WAY for them to identify YOUR directory code on the resident directory.

Access Code: Your system may be equipped with an “access code” that will allow you to open the door / gate by entering this code on the telephone entry system’s keypad. Your system administrator will advise you of YOUR access code if this option is available.

To use your access code, first press the key, and then enter your four-digit code .

System Administrator’s Note: Fill in the phone number and access granted number above, copy and distribute this sheet to the residents.

????

Your building / community has been equipped with a DoorKing Telephone Entry System that will provide communication for your guest from the lobby door / gated entrance to your home by use of the local telephone network. If you have any questions regarding the use or operation of this system, please see your System Administrator (building manager / HOA representative) or Call:

Phone #

RESIDENT INSTRUCTIONS

Page 58: Telephone Entry System - Doorking

UL Listed

www.doorking.com

DoorKing, Inc.120 S. Glasgow Avenue

Inglewood, California 90301U.S.A.

Phone: 310-645-0023Fax: 310-641-1586

Control a main entry point plus an additional entry point.

Installation/Owner’s Manual 1803 / 1808 / 18101803 / 1808 / 18101803 / 1808 / 1810

Use this manual for circuit board 1862-010 Revision O or higher.

Telephone Entry System

1800-060 Issued 7-19

Version B