telect fiber catalog
DESCRIPTION
Telect Fiber CatalogTRANSCRIPT
fiber
we simplify networks.TM
contents
Access Telect.com for online capabilities unique to our industry.Price Quoting • Onlineaccesstopricingandavailability–24/7/365 • Downloadablepricequotestohelpyoushareinformation withpeersandcontacts
Order Status • Onlineaccesstoorderstatus–24/7/365 • Schedulingandtracking,includinglinkstocommoncarriers
Invoicing and Accounting • Allshippedlinesarelinkedtoaninvoice • Downloadablecopiesofinvoicesforemailingand record-keeping
Purchased Product Lists • Detailedcross-references,customerandTelectpartnumbers • Productinformationlinks
telect.com
Fiber Optic ConnectivityProductSelectionTable ................................... F-4HDXHigh-DensityBulkhead-StylePanels ....... F-5LCXBulkhead-StylePatchandSplicePanels .. F-6SplitterandWDMModules .............................. F-8Wall-MountFiberPatchPanels ...................... F-91RU/NetworkEdgeModularPanel.............. F-10Tray-BasedFiberDistribution .........................F-11High-DensityFiberDistributionFrames.........F-16SplitterModulesforADF................................ F-19FiberPatchCords.......................................... F-20FiberAttenuators ........................................... F-21CableMgmt. .................................................. F-22CableMgmt.Specs&Max.CableDensity.... F-29IndexbyTerm ................................................ F-30IndexbyPartNumber.................................... F-31
F-4
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Patch, build and manage the ultimate network with Telect. We’re connected.
fiber
ScalableTray-BasedSystems
HighDensityBulkheadSystems
we simplify networks.
Offeringconnectivitysolutionsfor21stcenturytechnologies,Telectprovidesawealthof components,panelsandsystemsforconnecting opticalnetworks.Whetherforyourhigh-speed,highbandwidthbackboneorauniquelast-mileapplication,Telectcanprovidesolutionsthat ensuresignalintegrity,easeofinstallation, scalabilityforfuturegrowthandsimpleusability.
F-5
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Patch, build and manage the ultimate network with Telect. We’re connected.
fiber
AdvancedDistributionFrameScalableTray-BasedSystems
HighDensityBulkheadSystems
CableManagement
we simplify networks.TM
F-6
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Product Selection TableProduct
Capabilities
TerminationCount
CircuitA
ccess
CableManagem
ent
Com
patibility
KeyFeature/
Ap
plication
Bulkhead-StylePanels
Patch,splice,
splitter
Upto144per4RU
panel;1,440per
frame
Front-panelports
Entryandexitarcs
andloops
Standardfootprint
Simple,cost-effective
distributioninastandard
footprint
HDXHigh-Density
BulkheadSplitter
Panels
Splitter
Upto32modules/
128splittersper
4RUpanel
Front-panelports
Entryandexitarcs
andloops
Standardfootprint
Ultrahigh-densitysplitter
capabilitiesinastandard
bulkheadpanel
Tray-BasedDistribution,
RearA
ccess
Patch,splice,
storage
Upto144per4RU
panel;1,440per
frame
Elevatingadapters
Slidinglinkchains
androutingarcs
insidetrays
Fitsinstandard
racks
Highlevelofscalability
andcablemanagem
entfor
standardracks
Tray-BasedDistribution,
FrontA
ccess
Patch,splice,
storage
Upto144per4RU
panel;1,440per
frame
Elevatingadapters
Slidinglinkchains
androutingarcs
insidetrays
Fitsinstandard
racksandET
SI
frontaccess
cabinet
Totalfrontaccesstoallter-
minations;com
patiblewith
EMEA
standardpractices
High-DensityDistribution
Fram
e(ADF)
Patch,splitter
Upto96perm
odule
(144withLCcon-
nectors);2,304per
frame
Laterallyrotating
trays
Arcs,spools,water-
falls,etc.throughout
frame
System
-specific
frameincreases
densityandcable
managem
ent
Ultimatehigh-densityODF;
superiorcablemanagem
ent
andscalability
Wall-M
ountPatch
Panels
Patch,splice
Upto48perpanel
Bulkhead-style
ports;lockable
doors
Arcsandloops
insidepanel
Wall-m
ountable
Dem
arcationsolutionwith
separateproviderandcus-
tomercom
partm
ents;ideal
fortelcoclosets
1RUModularPanels
Patch,splice
Upto36per1RU
panel
Front-panel
access
Rear-p
anelcable
managem
entbar
Fitsinstandard
racks;wall-m
ount-
able
Com
pactnetworkedge
connectivitypanel
Fibe
r Opt
ic D
istr
ibut
ion
F-7
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Features• Modulardesignenablessimplescalabilityandcostmanagement• Upto32modulesperpanel(24modulesina19"chassis)• Uptosixportsonfrontandrearoermodule• Uptofour1x2splitterspermodule• Maximumdensityof128splittersina4RUchassis• Compliantwithallindustrystandards
SpecificationsBandpass 1310/1550±20nmDirectivity 50dBInsertionloss 50/50:≤3.9/3.9dB
55/45:≤3.4/4.3dB60/40:≤3.0/5.0dB65/35:≤2.6/5.5dB70/30:≤2.2/6.3dB75/25:≤1.9/7.0dB80/20:≤1.5/8.2dB85/15:≤1.3/9.3dB90/10:≤0.95/11.6dB95/5:≤0.7/14.9dB33/33/33:≤6.0/6.0/6.0dB25/25/25/25:(PLC)≤7.5/7.5/7.5/7.5dB20/20/20/20/20:≤9.0/9.0/9.0/9.0/9.0dB60/20/20:≤3.2/8.8/8.8dB
Polarizationloss 0.1dBmaximumReturnloss >55dB
HDX High-Density Bulkhead-Style Splitter Panels
Chassis and Accessories
Description Module Capacity Part Number
4RUStandard23”chassis 32 HDX-M4RU-2304RUStandard19”chassis 24 HDX-M4RU-1904RUADC®FL-2000compatiblechassis,rear-mount
32 HDX-FL4RU-230
4RUADC®FL-2000compatiblechassis,front-mount
32 HDX-FM4RU-230
Cablemanagementhookkit KIT-CMHOOK
Splitter Modules
Configuration Ratio Position in Panel Adapters Part Number
Dual1x3 60/20/20 Even SC/UPC HD56-4862-6161-SENDual1x3 60/20/20 Odd SC/UPC HD56-4862-6161-SODQuad1x3 60/20/20 Even LC/UPC HD56-4Q62-5151-SENQuad1x3 60/20/20 Odd LC/UPC HD56-4Q62-5151-SODTriple1x2 90/10 Either SC/UPC HD56-4T19-6161-SEN
Note: Additional module configurations are available. Typical usage for 60/20/20 splits include FTTx and other distribution applications. Typical 90/10 and 80/20 split usages include circuit monitoring.
HDX-FM4RU-230
Ultra high-density splitting in a standard bulkhead footprint.
High density doesn’t have to compromise usability
60/20/20Splitter
NEW!
F-8
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
LCX Bulkhead-Style Patch and Splice Panels
• SC,FC,LCandSTpatchplatesavailable• High-density144-terminationpaneloccupiesjust4RU• Standardfootprintforintegrationofpanelsintonewor existingapplicationsorplan
• Reversiblebracketstosupport19"or23"mounting,EIA/WECO• Designationlabelsincluded
Features
Full modularity allows users to grow into a panel, reducing up-front capital expense.
Patch Panels
SpecificationsEnvironmentalHumidity 0to90%,non-condensingTemperature -5to55deg.CMechanicalMaterial 4RU,3RU,2RUpanels:.080aluminum;
bottomofpaneliscold-rolledsteel1RUpanels:Cold-rolledsteel
Panelwidth 1RU:15"(381mm) 2RU,3RU,4RU:17"(432mm)
Paneldepth 11"(279mm)Panelmounting 19",23"orETSIComplianceAgencycompliance NEBS,ETSI,Zone4Seismicreliability
Termination Capacity
Height Patch Plates 6-Port Patch Plates 8-Port Patch Plate 12-Port Patch Plate Part Number1 RU 2 12 16 24 LCX-M1RU2RU 4 24 32 48 LCX-M2RU3RU 8 48 64 96 LCX-M3RU4RU 12 72 96 144 LCX-M4RU4RUFixedpatchpanel,equippedwith144SC/UPCadapters LCX-P141S
Description Part Number6-PortSC/UPC 055-0000-6010SC/APC 055-0000-6070FC/UPC 055-0000-2010FC/APC 055-0000-2070ST/UPC 055-0000-30108-PortSC/UPC 055-0000-6080SC/APC 055-0000-6090FC/UPC 055-0000-2080FC/APC 055-0000-2090ST/UPC 055-0000-308012-PortLC/UPC 055-0000-5010Blank FaceplateWhite 055-0000-9000
Patch Plates
8-PortFC/UPCPatchPlate(055-0000-2080)
6-PortST/UPCPatchPlate(055-0000-3010)
12-PortLC/UPCPatchPlate(055-0000-5010)
6-PortSC/UPCPatchPlate(055-0000-6010)
4RUModularOpticalPatchPanel(LCX-M4RU)
F-9
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Height Patch Plates Splice Trays Fiber Capacity Part Number2RU 2 1(included) Upto12 LCX-C2RU4RU 4 1 Upto24 LCX-C4RU6RU 8 2 Upto48 LCX-C6RU8RU 12 4 Upto96 LCX-C8RU
4RUModularOpticalSplicePanel(LCX-S4RU)
LCX Bulkhead-Style Patch and Splice Panels
Combination Patch and Splice Panels
Splice Panels
4RUCombinationPatchandSplicePanel(LCX-C4RU)
Description Part NumberSplicesleeves,12-pack KIT-SLEEVESBonding/groundingkit KIT-BONDIFCcableclamp KIT-CLMP4RU,Cablemanagementhook,front KIT-CMHOOK4RU,Cablemanagementhook,rear KIT-CMRHOOK3RU,Cablemanagementhook,front KIT-CMHOOK3RU3RU,Cablemanagementhook,rear KIT-CMRHOOK3RU
SpliceSleeves,12Pack(KIT-SLEEVES)
Bonding/groundingkit(KIT-BOND)
Height Maximum Splices Splice Trays Required Part Number1 RU 12 1included(donotorderadditional) LCX-S1RU2RU 24 1 LCX-S2RU3RU 48 2 LCX-S3RU4RU 96 4 LCX-S4RU4RU 144 6included LCX-S14124-Fibersplicecassette LCX-S-HSF(Imagebelow)
Note: Total patch terminations and splice capacity per panel must match. Maximum capacity listed above is based on splice chassis capacity.
Accessories
24-FiberSpliceCassette (LCX-S-HSF)
F-10
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Splitter and WDM Modules
Features• Fitinallstandardbulkhead-stylefiberpanels• Robustdesignfordurabilityandprotectionofcircuits• Upto8portsonthefront,4ontherear• Capacity:Four1x2splitterspermodule;maximumdensityof48splittersina4RUpanel
• WDMmodulesavailablein1310/1550nmoptions
Single Splitters
Dual Splitters
Quad Splitters
1x3SC/UPCSplitterModule(056-1333-6161)
Specifications
Non-intrusive fiber circuit testing and monitoring capabilities without sacrificing significant rack space.
Ratio Splits Input Output Output2Monitor Connectors PartNumber1x2 90/10 Front Front Front SC/UPC 056-1219-61611x2 80/20 Front Front Front SC/UPC 056-1228-61611x2 50/50 Front Front Front SC/UPC 056-1255-61611x3 33/33/33 Front Front Front SC/UPC 056-1333-61611x4 25/25/25/25 Front Front Front SC/UPC 056-1625-61611x5 20/20/20/20/20 Front Front Front SC/UPC 056-1520-6161
Ratio Splits Input Output Output2Monitor Connectors PartNumber1x2 90/10 Front Front Front SC/UPC 056-1419-61611x2 80/20 Front Front Front SC/UPC 056-1428-61611x2 50/50 Front Front Front SC/UPC 056-1455-61611x2 90/10 Front Front Rear SC/UPC 056-4419-61611x2 90/10 Rear Front Front FC/UPC 056-7419-21211x2 90/10 Rear Front Front LC/UPC 056-7419-51511x2 90/10 Rear Front Front SC/UPC 056-7419-6161
Ratio Splits Input Output Output2Monitor Connectors PartNumber1x2 90/10 Front Front Rear SC/UPC 056-4819-61611x2 80/20 Front Front Rear SC/UPC 056-4828-6161
Configuration Nm Input Output Output2Monitor Connectors PartNumberSingle 1310/1550 Front Front Front SC/UPC 056-1A00-6161Dual 1310/1550 Front Front Front SC/UPC 056-1B00-6161
WDM Modules
For different connectors, split ratios, or I/O/Monitor configurations,
call Telect: 800.551.4567.
Insertionloss(typical)
50/50%:<3.9/3.9dB55/45%:<3.4/4.3dB60/40%:<3.0/5.0dB65/35%:<2.6/5.5dB70/30%:<2.2/6.3dB75/25%:<1.9/7.0dB80/20%:<1.5/8.2dB85/15%:<1.3/9.3dB90/10%:<0.95/11.6dB95/5%:<0.7/14.9dB33/33/33%:<6.0/6.0/6.0dB25/25/25/25%:<7.5/7.5/7.5/7.5dB20/20/20/20/20%:<9.0/9.0/9.0/9.0/9.0dB60/20/20%:<3.2/8.8/8.8dB
Bandpass 1310/1550+/-20nmDirectivity 50dBPolarizationloss 0.1dB(max.)ReturnLoss >55dB(typical)
F-11
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Wall-Mount Fiber Patch Panels
Features• 24-or48-terminationspace-savingconfigurations• Cablestorageandbendradiuscontrolengineered intopanels
• Separatelockabledoorsforserviceandcustomer accesscontrol
• Easyinstallation,largedesignationareaforeachcircuit
EmptyWall-mountPatchPanel(055-8832-5000)
Terminations Patch Plates Capacity Part Number24 4 055-8632-500048 8 055-8832-5000
Panels
Patch Plates
Description Part NumberBonding/groundingkit KIT-BOND
Additional Items
SpecificationsDimensions24-portpanel 14.5"Wx14"Hx3.25"D
(368.3mmx355.6mmx82.6mm)48-portpanel 14.5"Wx14"Hx5.25"D
(368.3mmx355.6mmx133.4mm)Weight 6lbs.(2.7kg)Material AluminumColor WhiteEnvironmentalHumidity 0to90%,non-condensingTemperature -5to55deg.C
Maximum management and protection of valuable fiber optic cable and circuits at the edge of a network.
(KIT-BOND)
Description Part Number6-PortSC/UPC 055-0000-6010SC/APC 055-0000-6070FC/UPC 055-0000-2010FC/APC 055-0000-2070ST/UPC 055-0000-30108-PortSC/UPC 055-0000-6080SC/APC 055-0000-6090FC/UPC 055-0000-2080FC/APC 055-0000-2090ST/UPC 055-0000-308012-PortLC/UPC 055-0000-5010Blank FaceplateWhite 055-0000-9000
F-12
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
1 RU/Network Edge Modular Panel (ELF)
Features• Idealforremotesites,wirelesssites,hutsorother limited-spaceapplications
• Basicfiberconnectivityinthesmallestfootprint• Threemodulesfitinthestandard1RUchassis• Singlemodulecanbehousedinthewall-mountunit• Mountingbracketssuitablefor19"and23"EIAand WECOracks
Description Part Number1RU/3-modulechassis ELF-0000-2400Wall-mount/1-modulechassis ELF-0000-0800Blankfaceplate ELF-0000-0001
Terminations Function Connectors Part Number12 Patch SC/UPC ELF-PC12-SC0012 Patch&Splice SC/UPC ELF-SP12-SCPT12 Patch FC/UPC ELF-PC12-FC0012 Patch&Splice FC/UPC ELF-SP12-FCPT24 Patch LC/UPC ELF-PC24-LC00
Modules
Chassis
12-Term.SC/UPCPatchModule(ELF-PC12-SC00)
1RU3ModuleChassis (ELF-0000-2400)
12-Term.SC/UPCPatchandSpliceModule(ELF-SP12-SCPT)
12-Term.FC/UPCPatchandSpliceModule(ELF-SP12-FCPT)
12-Term.FC/UPCPatchModule(ELF-PC12-FC00)
See the Copper Connectivity catalog or Telect.com for more 1 RU modules.
Wall-Mount1ModuleChassis(ELF-0000-0800)
Designed for high-density, low circuit count environments—includes fiber patch and combo modules.
F-13
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
WhenaCanadiancommunicationsserviceprovidersetouttodeploynewcentralofficesitesinfivemajorcitiesacrossthenation,distributingandmanagingfiberoptictrafficwasakeyconcern.
Becauseoftheamountofdata—andtherefore,revenue—stream-ingthroughtheprovider’sopticalnetwork,deployingthemostefficientandeffectivecentraldistributionpointforfiberopticstookongreatsignificance.
The SituationInthiscase,theserviceprovidertargetedfivemetropolitanlocationsfornewtelephony-focusedcentraloffices.Ineachsite,standardscalledforaminimumof1,400opticalterminationsperframe,inastandardfootprint.Asinmostcentraloffices,thegoalwastonotonlymanagethetraffic,butalsotomaximizeavailablespacewiththehighestdensitysolutionpossible.
Tray-Based Fiber Distribution–Case StudyThe Solution: Telect Tray-Based ODFsTelectprovidedahigh-densityopticaldistributionframe(ODF) featuringatray-baseddistributionplatform(seedrawingbelow). Eachframehouses720patchesand720splices,foratotal terminationcapacityof1,440,allinastandard19-inchequipmentrack.
Basedoncapacityrequirementsofeachlocation,theservice providerinstalledeithertwoorfourframes.
Themultifunctional(patchandsplice)designenabledtheprovidertoscaleODFdeploymentasrequired;asingleframe,forexample,couldserveasmallerapplicationareaandstillmaintainfullpatchandsplicefunctionalityinasinglerepeatablesolution.
Details on Telect’s tray-based solutions are on the following pages.To read the complete case study, visit www.telect.com.
SampleConfiguration
F-14
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Description Part NumberTotal Rear Access12-fibersplicetray NSRA-S012-000-00024-fibersplicetray NSRA-S024-000-000Left Rear Entry, Right Front Exit12-fibersplicetray NSRX-S012-000-00024-fibersplicetray NSRX-S024-000-000Left Front Entry, Right Rear Exit12-fibersplicetray NSFX-S012-000-00024-fibersplicetray NSFX-S024-000-000
Splice Trays
Description Part NumberTotalRearAccess NSRA-STORLeftRearEntry,RightFrontExit NSRX-STORLeftFrontEntry,RightRearExit NSFX-STOR
24-Fiber Storage Trays
Tray-Based Fiber Distribution, Rear Access
• Systemprovidesanoptimalblendofhighdensity,cable managementandsimplifiedusage
• Rearaccesswithsideentry/exitforcable• Fitsopen-styleracksusedinNorthAmericanapplications• Advancedbendradiusprotection,portisolationanddefinedcablepathsprovidesimpleaccesstotargetedports
• Patentedfibermanagementchainsmaintaincablebendradiusandprotecteachfiberastraysareaccessed
• Elevatingadaptersincreaseaccessibilitytoindividualcircuits,maximizingusablespacewhileprotectingothers
• Scalablefrom12to144fiberterminationsinasinglechassis• Orderwithmultifibercablepre-terminatedatthefactoryforincreasedreliabilityandreducedinstallationtime
• Buildasystemtofitthespecificsofyourapplication—startwithachassisandaddindividualpatch,spliceandstoragetrays
• StandardchassiscolorisTelectwhite• 19"mountingbracketsincluded;23"orderedseparately
Features
Designed for locations where fiber drops or regular maintenance and rear access is required.
Description Part Number4RUhigh/6-traychassis NSRA-06TR-4RU3RUhigh/4-traychassis NSRA-04TR-3RU1RUhigh/1-traychassis NSRA-01TR-1RU
Chassis
4RUChassis(NSRA-06TR-4RU)
SpecificationsChassis Dimensions 4RU 19”Wx7”Hx10.4”D
483mmx178mmx264mm3RU 19”Wx5.25”Hx10.4”D
483mmx133mmx264mm1 RU 19”Wx1.75”Hx10.4”D
483mmx44mmx264mmConnections Terminationcount Upto144perchassisTerminationtype SC,FCSupportedmultifibercables IFC Supportedpatchcables Simplexorduplex,3mmand2mmEnvironmental Humidity 0to90%,non-condensingTemperature -5to55deg.CMechanical Minimumbendradius 30mmthroughoutsystemLaserradiationprotection Adapterlocationpreventsexposure
4RUChassiswithSixTrays
F-15
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Tray-Based Fiber Distribution, Rear Access
24-FiberStorageTray(NSRA-STOR)
24-FiberSpliceTray(NSRA-S024-000-000)
ElevatingAdapters
Connectors Capacity Part NumberTotal Rear AccessSC/APC 12-port NSRA-P012-ASC-000
24-port NSRA-P024-ASC-000SC/UPC 12-port NSRA-P012-USC-000
24-port NSRA-P024-USC-000FC/UPC 12-port NSRA-P012-UFC-000
24-port NSRA-P024-UFC-000LC/APC 12-port NSRA-PO12-ALC-000
24-port NSRA-PO24-ALC-000LC/UPC 12-port NSRA-PO12-ULC-000
24-port NSRA-PO24-ULC-000Left Rear Entry, Right Front ExitSC/APC 12-port NSRX-P012-ASC-000
24-port NSRX-P024-ASC-000SC/UPC 12-port NSRX-P012-USC-000
24-port NSRX-P024-USC-000FC/UPC 12-port NSRX-P012-UFC-000
24-port NSRX-P024-UFC-000LC/APC 12-port NSRX-PO12-ALC-000
24-port NSRX-PO24-ALC-000LC/UPC 12-port NSRX-PO12-ULC-000
24-port NSRX-PO24-ULC-000Left Front Entry, Right Rear ExitSC/APC 12-port NSFX-P012-ASC-000
24-port NSFX-P024-ASC-000SC/UPC 12-port NSFX-P012-USC-000
24-port NSFX-P024-USC-000FC/UPC 12-port NSFX-P012-UFC-000
24-port NSFX-P024-UFC-000LC/APC 12-port NSFX-PO12-ACL-000
24-port NSFX-PO24-ALC-000LC/UPC 12-port NSFX-PO12-ULC-000
24-port NSFX-PO24-ULC-000
Patch Trays
Description Part Number4RUchassismountingbracketkit(23") 3054193RUchassismountingbracketkit(23") 3054201RUchassismountingbracketkit(23") 02117-01
Accessories
F-16
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Tray-Based Fiber Distribution, Total Front Access
• Systemprovidesanoptimalblendofhighdensity,cableman-agementandsimplifiedusage
• Totalfrontaccesstoallfiberopticcabling• Anidealfitinlocationswherefiberadds,dropsorregularmain-tenanceandtotalfrontaccessisrequired
• HeavilyadoptedinEuropeanbayandcabinetapplications• Advancedbendradiusprotection,portisolationanddefinedcablepathsprovidesimpleaccesstotargetedports
• Patentedfibermanagementchainsmaintaincablebendradiusandprotecteachfiberastraysareaccessed
• Elevatingadaptersincreaseaccessibilitytoindividualcircuits,maximizingusablespacewhileprotectingothers
• Scalablefrom12to144fiberterminationsinasinglechassis• Orderwithmultifibercablepre-terminatedatthefactoryforincreasedreliabilityandreducedinstallationtime
• Buildasystemtofitthespecificsofyourapplication—startwithachassisandaddindividualpatch,spliceandstoragetrays
• StandardchassiscolorisTelectblack
Features
Ideal for central office fiber applications that require total front access.
4RUChassis(ESTF-06TR-4RU)
24-PortPatchTray(ESTF-P024-USC-000)
12-FiberSpliceTray(ESTF-S012-000-000)
SpecificationsChassis Dimensions4RUChassis 17.5”Wx6.9”Hx10.4”D
(445mmx175mmx264mm)3RUChassis 17.5”Wx5.3”Hx10.4”D
(445mmx134mmx264mm)2RUChassis 17.5”Wx3.4”Hx10.4”D
(445mmx86mmx264mm)1RUChassis 17.5”Wx1.7”Hx10.4”D
(445mmx42mmx264mm)MechanicalMinimumbendradius 30mmthroughoutsystemLaserradiationprotection AdapterlocationpreventsexposureConnections Terminationcount 12to144perchassis,1440per
cabinetTerminationtype SC,FC,ST,E2000,LCSupportedmultifibercables OSPandIFCSupportedpatchcables Simplexorduplex3mmand2mmEnvironmental Humidity 0to90%,non-condensingTemperature -5°to55°CCompliance
4RUChassiswithSixTrays
F-17
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Tray-Based Fiber Distribution, Total Front Access
Connectors 12-Port 24-PortSC/UPC ESTF-C012-USC-000 ESTF-C024-USC-000SC/APC ESTF-C012-ASC-000 ESTF-C024-ASC-000FC/UPC ESTF-C012-UFC-000 ESTF-C024-UFC-000LC/UPC ESTF-C012-ULC-000 ESTF-C024-ULC-000LC/APC ESTF-C012-ALC-000 ESTF-C024-ALC-000
Combination Patch + Splice Trays
Description Part Number24-fiberstoragetray ESTR
Storage Tray
Description Part Number130mmspool E-KIT-SPOOL-130MM35mmgatehalf-spool 027-0000-2000Trayremovaltool 129461-15mmbendlimitingtube,5mlong E900C-BKBLT524-tubeOSPbreakoutkit E900C-BK24M4-tubeOSPbreakoutkit E900C-BK412heatshrinkfusionsplicesleeves KIT-SLEEVES
Accessories
24-portPatch&Splice(Combo)Tray(ESTF-C024-USC-000)
Description Part Number4RUhigh/6-traychassis ESTF-06TR-4RU3RUhigh/4-traychassis ESTF-04TR-3RU2RUhigh/3-traychassis ESTF-03TR-2RU1RUhigh/1-traychassis ESTF-01TR-1RU
Chassis
Connectors 12-Port 24-PortSC/UPC ESTF-P012-USC-000 ESTF-P024-USC-000SC/APC ESTF-P012-ASC-000 ESTF-P024-ASC-000FC/UPC ESTF-P012-UFC-000 ESTF-P024-UFC-000LC/UPC ESTF-P012-ULC-000 ESTF-P024-ULC-000LC/APC ESTF-P012-ALC-000 ESTF-P024-ALC-000E2000/UPC ESTF-P012-UE2-000 ESTF-P024-UE2-000E2000/APC ESTF-P012-AE2-000 ESTF-P024-AE2-000
Description Part Number12-fibersplicetray ESTF-S012-000-00024-fibersplicetray ESTF-S024-000-000
Splice Trays
Patch Trays
F-18
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
High-Density Fiber Distribution Frames (ADF™)
• Industry-leadingterminationdensity:1152,1536or 2304(LC)terminations
• Uniqueslide-outtrayshousefiberterminations• Modularconstructionenablesscalabilityandcustomization• Standardframefootprintforexistingornewapplications.• Allcablepathsmanage30mmbendradiusprotection• Totalfrontaccesspermitssinglecraftspersonoperation withnopatchcord“fishing”orblindcablepulls
• 4.5-meterpatchcordcross-connectsanytwopoints withinaframe
Features
Standard26"Frame(ADF-26F-XI)
12"InterbayStoragePanel(ADF-12INT-XI)
Description Part NumberNorth American SystemStandard26"baseframe,overheadcableentry ADF-26F-XI12"Interbaystoragepanel ADF-12INT-XI5"Endpanel ADF-26EPETSI StandardStandard600mmx600mmx2200mmframe,overheadcableentry
ADF-600F-XI
300mmInterbaystoragepanel ADF-300INT-XI127mmEndpanel ADF-300EP
Frame System
Engineered for high-density central office applications, Telect’s ADF provides optimal fiber protection and access.
SpecificationsDimensionsFrame 26"Wx84"Hx24"D
(660mmx2134mmx610mm)Interbaystoragepanel 12"Wx84"Hx24"D
(305mmx2134mmx610mm)Endpanel 5"Wx84"Hx24"D
(127mmx2134mmx610mm)MechanicalFrame 215lbs.(97.5kg)Interbaystoragepanel 110lbs.(49.9kg)Endpanel 50lbs.(22.7kg)Material SteelColor WhiteEnvironmentalHumidity 0to90%,non-condensingTemperature -5to55deg.C
F-19
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
High-Density Fiber Distribution Frames (ADF™)
Description Part NumberAnchoringkitforconcrete,26"frame ADF-26ANCHORAnchoringkitforconcrete, 12"interbaypanel
ADF-12ANCHOR
Anchoringkitforraisedflooring, 26"frame
ADF-26COMPFLR
Anchoringkitforraisedflooring, 12"interbaypanel
ADF-12COMPFLR
26"x24"frameisolationpad ADF-26F-ISOPAD5"x24"endpanelisolationpad ADF-26EP-5-ISOPAD
Additional Items
ConfigurationExample:26"frameandmoduleswith storagepanelsonbothends
Terminations Connectors Side of Frame Part Number
72 SC/UPCLeft ADF-N-1SCLRight ADF-N-1SCR
72 SC/APCLeft ADF-N-1SALRight ADF-N-1SAR
96 SC/UPCLeft ADF-N-2SCLRight ADF-N-2SCR
96 SC/APCLeft ADF-N-2SALRight ADF-N-2SAR
144 LC/UPCLeft ADF-N-3LCLRight ADF-N-3LCR
Network Element Patch Modules
Fan-Out Patch ModulesTerminations Connectors Side of Frame Part Number
72 SC/UPCLeft ADF-F-1SCLRight ADF-F-1SCR
72 SC/APCLeft ADF-F-1SALRight ADF-F-1SAR
96 SC/UPCLeft ADF-F-2SCLRight ADF-F-2SCR
96 SC/APCLeft ADF-F-2SALRight ADF-F-2SAR
144 LC/UPCLeft ADF-F-3LCLRCRight ADF-F-3LCRRC
Interfacility ModulesTerminations Connectors Side of Frame Part Number
72 SC/UPCLeft ADF-I-1SCLRight ADF-I-1SCR
72 SC/APCLeft ADF-I-1SALRight ADF-I-1SAR
96 SC/UPCLeft ADF-I-2SCLRight ADF-I-2SCR
96 SC/APCLeft ADF-I-2SALRight ADF-I-2SAR
144 LC/UPCLeft ADF-I-3LCLRight ADF-I-3LCR
72-termSC/UPCInterfacility PatchModule(ADF-I-1SCL)
*Cablesnotincluded
72-termSC/UPCFan-Out PatchModule(ADF-F-1SCL)
72-termSC/UPCNetworkElementPatchModule(ADF-N-1SCL)
F-20
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
High-Density Fiber Distribution Frames (ADF™)
Standard length patch cordsTelectstandardizedonasingle-length4.5mpatchcordforADFcross connectionstosimplifytheorderingprocess.
Comprehensive designationGenerouscircuitdesignationareasenablefast,andmoreimportantly, accuratecircuitidentification.
Designed for safety complianceThelightweight,heavy-dutyADFisengineeredforZone4earthquake reliability,noline-of-sightlaserhazards,andflammabilitysafety.
30mm bend radius protectionSpools,postsandarcsthroughoutthesystemmaintain30mm bendradius.
Built-in eye protection from laser radiationTraydesignprovidessimpleeyeprotectionfromexposedport laserradiation.
Industry-leading densityPatchmodulesarecomprisedofhigh-densitytrays.
Advanced cable managementCablemanagementispartofeveryADFcomponent,includingthepatchmodules.
Unmatched ease of use Traysrotateoutwardforsimpleaccess.Cablemanagementspoolsalsoenableeasydeploymentandongoingusage.
F-21
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Splitter Modules for the ADF™
Nowyoucangainthedensity,usabilityandcablemanagementoftheADFinsplitterapplications.Telect’snewsplittersystemfortheADFisanidealsolutionforhigh-densityFTTx/PONapplications,providingahighlyscalableanddynamicplatformfordelivering opticalcircuitstomultipleendusers.
SpecificationsPerformanceInsertionLoss: <0.20dBtypical/.40dBmax.
typicalReturnLoss: <-55dBtypical(UPC)
<-65dBtypical(APC)Mechanical Width 7.1"(180mm)Height 10"(254mm)Depth 20"(508mm)Color WhiteTerminationcount Upto6inputs/192outputs
• High-countsignalsplitsforhigh-bandwidthapplications• IdealforPONarchitectures–mixhigh-densitysplitters,OLT inputsandbackbonefiberinasingleframe
• Functionasahigh-volumedistributionpointorasastandalonesysteminsmallerlocations
• Highlyscalable–uptosevenchassisperADFside,totalof 1,296outputsmaximum
• Chassis: » Uptosix1x32splittermodules;maximumof192outputfibers » SamefootprintandinstallationasotherADFmodules » Internalcablemanagementroutesandprotectsfibers
• Modules: » 1x32or1x16splitterinacompactfootprint » 4.5-meteroutputfiberlengthstandard » Blueinputfiberforeasyrecognition;alloutputs individuallylabeled
Features
The Ultimate Splitter System for FTTx/PON Applications: Splitter Solutions for the ADF
Description Part NumberSC/APC ADF-P-MR0SCALC/APC ADF-P-MR0LCA
Description Part NumberPassive1x16,SC/APC ADF-P-S-SCA-16Passive1x32,SC/APC ADF-P-S-SCA-32Passive1x16,LC/APC ADF-P-S-LCA-16Passive,1x32,LC/APC ADF-P-S-LCA-32
Description Part NumberConnectorparkingpanel ADF-PRKL
Chassis
Splitter Modules
Accessories
NEW!
F-22
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Endface DefectsFibercore 0nm²Modefielddiameter 0nm²Ferrulecontactzone <10nm²Testingandinspection LotsampleEpoxyTemperaturecoefficient 120tgCuringmethod OutgassedResidualepoxy NotspecifiedConfiguration ControlDatatracking ILandRLdataprintedoneach
cable;datastoredinTelectdatabase
Serialization Eachcableserialized
24-Fiber10mSC/UPCMultifiberCable(F124S-SP-M010-STPT)
Fiber Optic Patch Cords and Multifiber Cable Assemblies
• Fulllineofpatchcords,multfiberindoorcables(MIC),andout-sideplant(OSP)cablesavailable
• Highestqualitycomponentsforindustry-leadingperformanceandreliability
• Singlemode(8/125)andmultimode(50/125or62.5/125)op-tionsavailable
• Connectoroptionsinclude: » SC/UPC » SC/APC » FC/UPC » FC/APC » LC/UPC » LC/APC » E2000/APC » E2000/UPC » ST/UPC
• Cabletypeoptionsinclude: » Riser » Plenum » Lowsmoke/zerohalogen » Bend-insensitive
• Hybridcables(SC-FC,SC-ST,etc.)alsoavailable• Customlengthsandbreakoutsavailable• TelcordiaGR-326certified
PatchCords• Simplexandduplexcableavailable• Outerjacketdiameteroptionsinclude:
» 900um » 1.7mm » 2.0mm » 3.0mm
MultifiberCableAssemblies• StrandedorribbonMICavailable• Fibercountoptionsinclude2,4,6,8,12,24,36,48,6072, 96and144
Features
Multimode (50/125) 3 mm
SpecificationsPerformanceInsertionloss 0.20dBtypical/.4dBmaxReturnloss -55dBGeometryRadiusofcurvature 7-25mmApexoffset 0-50umRadialfiberheight -50to+50nmAngularoffset <0.3degreesFiberroughness 0-25nmFerruleroughness 0-50um
SingleMode2mm1mSC/UPCDuplexCable
(F14-SSG-M001-0)
For standard configurations, part numbers, pricing and additional information, visit Telect.com or call 800.551.4567.
F-23
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Fiber Attenuators
Specifications
• Buildoutstylein-linedesign• Engineeredandmanufacturedwithcontinuouslightabsorbing,metal-iondopedfiberforgreaterenvironmentalstabilityandbet-terbackreflectionandnoiseperformance
• Soldinpacksof10• Environmentallystableovertemperature,humidityandvibration• Highperformance:lowpolarizationdependentlossPDL• Simpleplug-instyleenablesrapiddeployment• TelcordiaGR-910compliant• Wavelengthindependent:1310/1550nm• ConnectoroptionsincludeSC,ST,FCandLC
Features
10-Pack SC FC ST LC3dB 555-3333-003 555-3030-003 555-3131-003 555-3434-0035dB 555-3333-005 555-3030-005 555-3131-005 555-3434-00510dB 555-3333-010 555-3030-010 555-3131-010 555-3434-01015dB 555-3333-015 555-3030-015 555-3131-015 555-3434-015
3dBFCOpticalAttenuator(555-3030-003)
3dBSTOpticalAttenuator(555-3131-003)
3dBSCOpticalAttenuator(555-3333-003)
3dBLCOpticalAttenuator(555-3434-003)
Accuracy 1-10dB:+/-1dBtypical10-25dB:+/-10%dBtypical
Maxinputpower 200mW(+23dBm)Polarizationloss <0.1dBReturnloss -55dBtypical
F-24
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
OverviewSimplifyyournextcablemanagementsysteminstallationwithWaveTrax®,Telect’sraceway-basedsystemdesignedtoreduceinstallationandmaterialcosts.WaveTraxcombinessolidtroughandflexiblelinksforthebroadestrangeofcomponentsintheindustry.Strongcomponentconstructionreducesthenumberofbracketsandjunctionsrequired.Snap-togetherassemblyensuresthatyoursystemisinstalledquicklyandcorrectlythefirsttime.
WaveTraxincludestrough,transitions,intersections,drops,reducers,couplingkitsandothercomponentstohelpuserscreatefullycustomizable,secureandversatilecableroutingpathsbetweenfiberdistributionframesandterminalequipment.
Sample Layout TheimagebelowprovidesasamplingofTelect’sWaveTraxandCableLinksproductsandhowtheyfittogetherinanon-standardconfiguration.Withstraightcableruns,varioustransitionsanddropsintoequipmentracks,youcanseehoweachofthesepiecesmightfitintoyourhorizontalandverticalcablemanagementsystem.Differentcomponentsizesareavailabletofitthespecificcapacityrequirementsofvirtuallyanyapplication.
Cable Management
Features
1
16
13
7
5
317
18
1920
8
10
12
24
11
6
14
15
9
Parts List1.Trough2.Reducer3.Trumpetattachment4.Endcap5.Flexibletube6.T-Junction7.Slottedduct8.Expressoff-ramp9.CableLinks®(2")
10. Centerdrop11. Systemadapter12. Intersection13. Dropattachment14. 45˚elbow15. Couplingkit16. L-Junction17. Upsweep18. Downsweep19. CableLinks®adapter20. CableLinks® (6")
• Availablein2",4",6"and12"widths• Allcomponentsmaintainaminimum2"bendradius• Troughsupportsupto175lbs.atupto6'intervals• Easyreconfigurationwithsnap-oncomponents• Flexiblelinksenablefurthercustomization• Simplifieddesignlowerscostofinstallationandownership• Componentcoversavailableforadditionalsecurity• MadeofUL94V-0plastic(selecttransitionsmadeofaluminum)• NEBSandETSIcertified• Zone4seismicrated• RUSlisted
F-25
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
CableLinks® Flexible Cable Management Links
Features• Superiorverticalcablemanage-mentthatcomplementstraditionaloverheadfiberduct
• Enablesflexiblecableroutinganduniquepathwayswhilemaintainingbendradius
• Providestheflexibilityofsplittube,themanageabilityofslottedduct,andadvancedversatility
• Cleanandfastinstallation: » Nosawsrequired–parts snaptogether
» Flexiblelinksmeanthatracksdonothavetobeperfectlyalignedtooverheadtroughsanddrops
• Madeofhigh-qualitymaterialsfordurabilityandperformance
• Fullycompatiblewithallstandardracewayandtroughsystems• 2"x2"yellowlinksavailableinafullpalletforvolumesavingsandconvenience
Simple to assemble and ideal for flexible cable management, horizontal or vertical.
Description Part NumberSinglelink,yellow 027-0000-4200Singlelink,black WT2E-CBLX-BLKPallet,yellow(1,664links) 027-0000-42PLT
Description Part Number6",yellow 027-2000-64156"to2",yellow 027-1000-64724",yellow 027-2000-40154"to2",yellow 027-2000-4215
Description Part Number6",yellow 027-1000-64904",yellow 027-2000-40902",yellow 027-1000-4207
2" x 2" CableLinks
Description Part NumberSinglelink,yellow 027-0000-4000Singlelink,black WT4E-CBLX-BLK
4" x 4" CableLinks
Description Part NumberSinglelink,yellow 027-0000-6400
4" x 6" CableLinks
AdaptersCableLinks to Overhead Express Off-Ramp, T’s L’s and Intersections
CableLinks to Trough Adapter
Specifications Material UL94V-0fire-retardantplasticCapacity 2":4003mmfibers
4":8003mmfibers6":10003mmfibers
Linksperfoot 2":34":1.56":Approx.1.3
Agencycompliance NEBS3,ETSI
BracketsDescription Part NumberAdjustablerack-mountbracket 027-1000-4211 Must be used with Coupling Kit page F-24
F-26
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Troughs• Standard6'length,canbecuttofit• I-Beamdesignreducesthenumberofsupportbracketsrequired• Requiresanotchingtool(seepg.F-25)
Size Part Number2" 027-2000-4206
4" 027-2000-4001
6" 027-2000-6401
12" 027-2000-12406
Coupling Kits• Snap-fitconnectorfortroughsandtransitions• Primarymountingfixturesforbrackets
Size Part Number2" 027-2000-4299
4" 027-2000-4099
6" 027-2000-6499
12" 027-1000-12499
L-Transitions• Createa90°turninahorizontalrun• Helptoguidecablearoundobstacles
Size Part Number2" 027-2000-4224
4" 027-2000-4024
6" 027-2000-6424
12" 027-2000-12424
WaveTrax® Cable Management Components
Express Off-Ramp• Modularexitthatsimplysnapsontothesideofanexistingtroughrun
• Guidescableupandoverthesidewallthendownintothe desiredbay
• Fits4"andlargertrough•2"includesCableLinksadapter
Size Part Number
2" 027-2000-42644" 027-2000-4065
Simple installation, comprehensive com-ponents – the total cable management solution.
T-Transitions• Addsa90°exittoatroughandattachessimplytotroughwith acouplingkit
Size Part Number
2" 027-2000-42104" 027-2000-40106" 027-2000-6410
12" 027-2000-12410
Size Part Number
2" 027-2000-42304" 027-2000-40306" 027-2000-643012"x12" 027-2000-12430
Intersection• Allowtwoperpendiculartroughstocross• Availablewithequalwidthsordifferentwidthsoneach crossingroute
• Couplingkitrequiredateachconnection
Drop Attachments• Snapontohorizontalrunstoprovidearadiusedtransitionintoarackorbay
• Largerdropsreducetosmallersizes,minimizingthenumberofcomponentsrequiredtodelivercabletothebay
• 2"dropsrequiretheuseofajunction;othersizessnap ontotransitions
Size Part Number
2" 027-2000-4277
4" 027-2000-4077
6" 027-2000-6477
12"to6" 027-2000-12477
F-27
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
45° Upsweeps• Createanupwardturninahorizontalrun• Idealforoverheadapplicationswhentransitioningfor elevationchanges
• Madeofaluminum
Size Part Number2" 027-1000-4287
4" 027-1000-4487
6" 027-1000-6487
12" 027-1000-12487
45° Elbows• Createasidewaysturninahorizontalrun• Idealfornegotiatingaroundobstacles• Madeofaluminum• Couplingkitrequiredateachconnection
Size Part Number2" 027-1000-4289
4" 027-1000-4489
6" 027-1000-6489
12" 027-1000-12489
45° Downsweeps• Createadownwardturninahorizontalrun• Idealforoverheadapplicationswhentransitioningfor elevationchanges
• Madeofaluminum
Size Part Number2" 027-1000-4288
4" 027-1000-4488
6" 027-1000-6488
12" 027-1000-12488
WaveTrax® Cable Management Components
90° Upsweeps• Createanupwardturninahorizontalrun• Idealforunderfloorapplicationswhentransitioningupintoabay• Madeofaluminum
Size Part Number2" 027-1000-4273
4" 027-1000-4473
6" 027-1000-6473
12" 027-1000-12473
Notching Tool• Usedtocreatethesnap-on effectoncut-to-fittrough
• Eachinstallationshouldhaveatleastonenotchingtoolonsite
Part Number027-2000-1100
F-28
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
WaveTrax® Cable Management Components
Size Part Number2" 027-2000-42754" 027-2000-40756" 027-2000-6475
12" 027-2000-12475
Trumpet Attachment• Providearadiusedflareoffofahorizontalsystem,creatinga verticaltransitionthat’sidealforspace-constrainedenvironments
• 2"trumpetsrequiretheuseofajunction;othersizessnap ontotransitions
Center Drop• Createaninlinedropinahorizontalrun• Providedirectaccesstothebaywhileminimizingthenumberofcomponentsrequiredtotransitionfromthehorizontalruntotheverticaldownspout
Size Part Number
2" 027-1000-42274" 027-2000-44266" 027-2000-642612"to4" 027-1000-1242712"to6" 027-1000-12426
Reducers• Connecttroughortransitiontosmallercomponent,providingbendradiusprotection
• Eachendrequiresacouplingkit,endcapordropattachment
Size Part Number4"to2" 027-2000-4050
6"to4" 027-2000-6450
12"to6" 027-2000-12450
12"to8" 027-2000-12458
Trough End Attachments• Enableanendcap,downspoutortrumpettosnaponto theendofatrough
• Madeofaluminum
Size Yellow2" Notrequired
4" 027-2000-4009
6" 027-2000-6409
12" 027-2000-12409
End Caps• Provideclosureattheendofatransition• 4",6"and12"troughsrequireatroughendattachment
Size Part Number2" 027-2000-4208
4" 027-2000-4008
6" 027-2000-6408
12" 027-2000-12408
Competitive System Adapters• SeamlesslyintegrateTelectcablemanagement withothercablemanagementsystems
• Requirestheuseofanotchingtool(seepg.F-25)• Ditel,Siemon,Newton,Warren&Browndonot requireadapters*
Size Matches ADC & Panduit*
4" 027-2000-4007
6" 027-2000-6407
12" 027-1000-12407
*Alltrademarksarepropertyoftheirrespectiveowners.
F-29
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Size Part Number
2" 027-2000-4278
4" 027-2000-4078
6" 027-2000-6478
12"to6" 027-2000-12478
Drop Attachment Cover
Size Part Number
2" 027-2000-42314" 027-2000-40316" 027-2000-643112" 027-2000-12431
Intersection Cover
WaveTrax® Cable Management Component Covers
Size Part Number
2" 027-2000-42114" 027-2000-40116" 027-2000-641112" 027-2000-12411
T-Transition CoverSize Part Number
2" 027-2000-42634" 027-1000-4066
Express Off-Ramp Cover
L-Transition CoversSize Part Number2" 027-2000-4225
4" 027-2000-4025
6" 027-2000-6425
12" 027-2000-12425
Trough CoversSize Part Number
2" 027-2000-4202
4" 027-2000-4002
6" 027-2000-6402
12" 027-2000-12402
Reducer CoversSize Part Number
4"to2" 027-2000-4051
6"to4" 027-2000-6451
12"to6" 027-2000-12451
Visit Telect.com for additional component covers as well as: • WaveTrax videos • CableLinks videos • Product documentation
F-30
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Cable Management Brackets
Threaded Rod Brackets• Providealow-profileadjustablemountingattachmenttothreadedrod
• Removablelockbracketsimplifiesinstallation• Usewithallthreadkit
Size Part NumberFor2" 027-1000-4251For4"to6" 027-1000-4051For12" 027-1000-12405
Allthread Kits• Mounttomoststylesofcablerackandauxiliarybar• Includes5/8"x24"threadedrod,clamshellbrackets andhardware
• Provideseaseofadjustmentinmountingbracketshanging fromoverheadstructures
Size Part NumberStandard5/8"kit 027-1000-4002
Center Trough Brackets• Twoslidingcatchesmountdirectlytomostbracketsandattachtotroughasamid-spansupport
• Requiresadditionalbrackettomounttoallthreadorladderrack
Size Part NumberFor2" 027-2000-4260For4"to12" 027-2000-4060
Adjustable Brackets• Oftenusedforcablemanagementtravelingverticallydownanequipmentrack
• Mountsdirectlytorackflange• Providesa1.5"offsetand0.25"adjustmenttoward orawayfromtheframe
• Junctionssnapontothebracket,eliminatingsmallhardware
Description Part NumberFortrough 027-1000-4216ForCableLinks 027-1000-4211
Center Below Brackets• Supporttroughdirectlyabovethreadedrod• Usewithallthreadkit
Size Part NumberFor2" 027-1000-4252For4"or6" 027-1000-4052For12" 027-1000-1250
C-Brackets• Supporttroughdirectlybelowthreadedrod• Usewithallthreadkit
Size Part NumberFor2" 027-1000-4253For4"or6" 027-1000-4053For12" 027-1000-1253
Cable Rack Brackets
Size Part NumberFor2" 027-1000-4260For4"or6" 027-1000-4062
Universal Brackets• Mountstothreadedrod,ladderrackorverticalsurfaceto support2"channelatadjustableheights
• UsewithanAllthreadKit(027-1000-4002)forthreaded rodmounting
Size Part Number2"bracketkit 027-2000-42054"bracketkit 027-1000-4004
• Supportstroughlevelwith standardcablerack
• Simpletoinstallandadjust
F-31
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Additional Cable Management Components
Flexible Tube Adapters• Attaches2"flexibletubetotransitionortroughendattachment
• Availableinsingleordualdesigns(foroneortwoflexibletubes)
Size Part Number4"single 027-2000-20004"dual 027-2000-4016
Size Part Number4"dual 027-2000-4018
Flexible Tube Adapter Cover
Flexible Tube• Simpleandinexpensivewaytoorganizeandbundlecable• Tubeis2"inwidth,20"inlength,with split-tubeaccess
Slotted Duct• 2"exitsalignonbothsidesofthecomponentforaccess• Eachkitcomeswitha6'slottedtrough,a6'cover,twocouplingkitsandtwosnap-onbracketsformountingtoequipmentracks
Size Part Number2" 027-2000-42034" 027-2000-4403
Size Part Number2" 027-2902-0020
Maximum Cable DensityUse this table as a guide to determine the best width to support your application.Trough Width Max. Patch Cord Density2" Patch Cord Pile-Up in Trough 2mm Patch Cords 3mm Patch Cords2"trough 560 2404"trough 1,120 4806"trough 1,680 72012"trough 3,360 1,9203" Patch Cord Pile-Up in Trough 2mm Patch Cords 3mm Patch Cords4"trough 1,680 7206"trough 2,520 1,08012"trough 5,040 2,1604" Patch Cord Pile-Up in Trough 2mm Patch Cords 3mm Patch Cords4"trough 2,240 6906"trough 3,360 1,14012"trough 6,720 2,880
F-32
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
By TermIndex
1RUModularpanel,F-101RUPatchandsplicemodules,F-101RUPatchmodules,F-10
A Accessories,bulkhead-stylepanels,F-7Accessories,high-densityfiberdistributionframes,F-17Accessories,tray-baseddistribution,frontaccess,F-15Accessories,tray-baseddistribution,rearaccess,F-13Attenuators,F-21
BBrackets,cablemanagement,F-28 Adjustablebrackets,F-23,F-28 Centerbelowbrackets,F-28 C-Brackets,F-28 Cablerackbrackets,F-28 Universalbrackets,F-28 Threadedrodbrackets,F-28 Allthreadkits,F-28 Centertroughbrackets,F-28 CCablemanagement,F-22-F-29 Trough,F-22,F-24 Reducer,F-22,F-26 Trumpetattachment,F-22,F-26 Endcap,F-22,F-26 Flexibletube,F-22,F-29 T-Transition,F-22,F-24 Slottedduct,F-22,F-29 Expressoff-ramp,F-22,F-24 CableLinks,F-22,F-23 Centerdrop,F-22,F-26 Systemadapter,F-22,F-26 Intersection,F-22,F-24 Dropattachment,F-22,F-24 45ºElbow,F-22,F-25 Couplingkit,F-22,F-24 L-Transition,F-22,F-24 45ºUpsweep,F-22,F-25 45ºDownsweep,F-22,F-25 Adapter,CableLinkstotrough,F-22,F-23 Adapter,CableLinkstointersections,F-23 90ºUpsweep,F-25 Troughendattachment,F-26 Componentcovers,F-27,F-29 Adapter,flexibletube,F-29Cablemanagementhooks,bulkhead-stylepanels,F-7Combinationpanels,bulkhead-style,LCX,F-7
HHigh-densityfiberdistributionframes,F-16 Framesystem,F-16 Accessories,F-17 Networkelementpatchmodules,F-17 Fan-outpatchmodules,F-17 Interfacilitymodules,F-17 Splittermodules,F-19High-densityframesystem,NorthAmerican,F-11
MMaximumcabledensity,cablemanagement,F-29Multifiberindoorcable(MIC),F-20
NNotchingtool,cablemanagement,F-25
PPatchcords,F-20Patchpanels,bulkhead-style,LCX,F-6Patchpanels,wall-mount,F-9Patchplates,bulkhead-style,F-6,F-9Productselectiontable,F-4
SSplicepanels,bulkhead-style,LCX,F-7Splitters,F-5 ADFHigh-densityframe,F-19 HDXHigh-densitybulkhead,F-5 LCXBulkhead-style,F-8 TTray-baseddistribution,casestudy,F-11Tray-baseddistribution,frontaccess,F-14 Accessories,F-15 Chassis,F-15 Combinationtrays,F-15 Patchtrays,F-15 Splicetrays,F-15 Storagetray,F-15Tray-baseddistribution,rearaccess,F-12 Chassis,F-12 Storagetrays,F-12 Splicetrays,F-12 Patchtrays,F-13 Accessories,F-13 WWDMmodules,F-8
F-33
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
By Part NumberIndex
02117-01 ....................... F-13129461-1 ....................... F-15305419 .......................... F-13305420 .......................... F-13027-0000-2000 .............. F-15027-0000-4000 .............. F-23027-0000-4200 .............. F-23027-0000-42PLT ........... F-23027-1000-12405 ............ F-28027-1000-12407 ............ F-26027-1000-12426 ............ F-26027-1000-12427 ............ F-26027-1000-12473 ............ F-25027-1000-12487 ............ F-25027-1000-12488 ............ F-25027-1000-12489 ............ F-25027-1000-12499 ............ F-24027-1000-1250 .............. F-28027-1000-1253 .............. F-28027-1000-4002 .............. F-28027-1000-4004 .............. F-28027-1000-4051 .............. F-28027-1000-4052 .............. F-28027-1000-4053 .............. F-28027-1000-4062 .............. F-28027-1000-4066 .............. F-27027-1000-4207 .............. F-23027-1000-4211 .....F-23,F-28027-1000-4216 .............. F-28027-1000-4227 .............. F-26027-1000-4251 .............. F-28027-1000-4252 .............. F-28027-1000-4253 .............. F-28027-1000-4260 .............. F-28027-1000-4273 .............. F-25027-1000-4287 .............. F-25027-1000-4288 .............. F-25027-1000-4289 .............. F-25027-1000-4473 .............. F-25027-1000-4487 .............. F-25027-1000-4488 .............. F-25027-1000-4489 .............. F-25027-1000-6472 .............. F-23027-1000-6473 .............. F-25027-1000-6487 .............. F-25027-1000-6488 .............. F-25027-1000-6489 .............. F-25027-1000-6490 .............. F-23027-2000-1100 .............. F-25027-2000-12402 ............ F-27027-2000-12406 ............ F-24027-2000-12408 ............ F-26027-2000-12409 ............ F-26027-2000-12410 ............ F-24027-2000-12411 ............ F-27027-2000-12424 ............ F-24027-2000-12425 ............ F-27027-2000-12430 ............ F-24
Part No. Page Part No. Page Part No. Page027-2000-12431 ............ F-27027-2000-12450 ............ F-26027-2000-12451 ............ F-27027-2000-12458 ............ F-26027-2000-12475 ............ F-26027-2000-12477 ............ F-24027-2000-12478 ............ F-27027-2000-2000 ............. F-29027-2000-4001 .............. F-24027-2000-4002 .............. F-27027-2000-4007 .............. F-26027-2000-4008 .............. F-26027-2000-4009 .............. F-26027-2000-4010 .............. F-24027-2000-4011 .............. F-27027-2000-4015 .............. F-23027-2000-4016 .............. F-29027-2000-4018 .............. F-29027-2000-4024 .............. F-24027-2000-4025 .............. F-27027-2000-4030 .............. F-24027-2000-4031 .............. F-27027-2000-4050 .............. F-26027-2000-4051 .............. F-27027-2000-4060 .............. F-28027-2000-4065 .............. F-24027-2000-4075 .............. F-26027-2000-4077 .............. F-24027-2000-4078 .............. F-27027-2000-4090 .............. F-23027-2000-4099 .............. F-24027-2000-4202 .............. F-27027-2000-4203 .............. F-29027-2000-4205 .............. F-28027-2000-4206 .............. F-24027-2000-4208 .............. F-26027-2000-4210 .............. F-24027-2000-4211 .............. F-27027-2000-4215 .............. F-23027-2000-4224 .............. F-24027-2000-4225 .............. F-27027-2000-4230 .............. F-24027-2000-4231 .............. F-27027-2000-4260 .............. F-28027-2000-4263 .............. F-27027-2000-4264 .............. F-24027-2000-4275 .............. F-26027-2000-4277 .............. F-24027-2000-4278 .............. F-27027-2000-4299 .............. F-24027-2000-4403 .............. F-29027-2000-4426 .............. F-26027-2000-6401 .............. F-24027-2000-6402 .............. F-27027-2000-6407 .............. F-26027-2000-6408 .............. F-26027-2000-6409 .............. F-26027-2000-6410 .............. F-24
027-2000-6411 .............. F-27027-2000-6415 .............. F-23027-2000-6424 .............. F-24027-2000-6425 .............. F-27027-2000-6426 .............. F-26027-2000-6430 .............. F-24027-2000-6431 .............. F-27027-2000-6450 .............. F-26027-2000-6451 .............. F-27027-2000-6475 .............. F-26027-2000-6477 .............. F-24027-2000-6478 .............. F-27027-2000-6499 .............. F-24027-2902-0020 .............. F-29055-0000-2010 .........F-6,F-9055-0000-2070 .........F-6,F-9055-0000-2080 .........F-6,F-9055-0000-2090 .........F-6,F-9055-0000-3010 .........F-6,F-9055-0000-3080 .........F-6,F-9055-0000-5010 .........F-6,F-9055-0000-6010 .........F-6,F-9055-0000-6070 .........F-6,F-9055-0000-6080 .........F-6,F-9055-0000-6090 .........F-6,F-9055-0000-9000 .........F-6,F-9055-8632-5000 ................ F-9055-8832-5000 ................ F-9056-1219-6161 ................ F-8056-1228-6161 ................ F-8056-1255-6161 ................ F-8056-1333-6161 ................ F-8056-1419-6161 ................ F-8056-1428-6161 ................ F-8056-1455-6161 ................ F-8056-1520-6161 ................ F-8056-1625-6161 ................ F-8056-1A00-6161 ............... F-8056-1B00-6161 ............... F-8056-4419-6161 ................ F-8056-4819-6161 ................ F-8056-4828-6161 ................ F-8056-7419-2121 ............... F-8056-7419-5151 ................ F-8056-7419-6161 ................ F-8555-3030-003 ................ F-21555-3030-005 ................ F-21555-3030-010 ................ F-21555-3030-015 ................ F-21555-3131-003 ................ F-21555-3131-005 ................ F-21555-3131-010 ................ F-21555-3131-015 ................ F-21555-3333-003 ................ F-21555-3333-005 ................ F-21555-3333-010 ................ F-21555-3333-015 ................ F-21555-3434-003 ................ F-21
F-34
©Telect,Inc.,AllRightsReserved,F3/121.509.926.6000::telect.com
Part No. Page Part No. Page
ByPartNumberIndex
Part No. Page555-3434-005 ................ F-21555-3434-010 ................ F-21555-3434-015 ................ F-21ADF-12ANCHOR .......... F-17ADF-12COMPFLR ........ F-17ADF-12INT-XI ............... F-16ADF-26ANCHOR .......... F-17ADF-26COMPFLR ........ F-17ADF-26EP ..................... F-16ADF-26EP-5-ISOPAD ... F-17ADF-26F-ISOPAD ......... F-17ADF-26F-XI ................... F-16ADF-300EP ................... F-16ADF-300INT-XI ............. F-16ADF-600F-XI ................. F-16ADF-F-1SAL .................. F-17ADF-F-1SAR ................. F-17ADF-F-1SCL ................. F-17ADF-F-1SCR ................. F-17ADF-F-2SAL .................. F-17ADF-F-2SAR ................. F-17ADF-F-2SCL ................. F-17ADF-F-2SCR ................. F-17ADF-F-3LCLRC ............ F-17ADF-F-3LCRRC ............ F-17ADF-I-1SAL ................... F-17ADF-I-1SAR .................. F-17ADF-I-1SCL ................... F-17ADF-I-1SCR .................. F-17ADF-I-2SAL ................... F-17ADF-I-2SAR .................. F-17ADF-I-2SCL ................... F-17ADF-I-2SCR .................. F-17ADF-I-3LCL ................... F-17ADF-I-3LCR .................. F-17ADF-N-1SAL ................. F-17ADF-N-1SAR ................ F-17ADF-N-1SCL ................. F-17ADF-N-1SCR ................ F-17ADF-N-2SAL ................. F-17ADF-N-2SAR ................ F-17ADF-N-2SCL ................. F-17ADF-N-2SCR ................ F-17ADF-N-3LCL ................. F-17ADF-N-3LCR ................. F-17ADF-P-MR0LCA ............ F-19ADF-P-MR0SCA ........... F-19ADF-PRKL .................... F-19ADF-P-S-LCA-16 .......... F-19ADF-P-S-LCA-32 .......... F-19ADF-P-S-SCA-16 .......... F-19ADF-P-S-SCA-32 .......... F-19E900C-BK24M .............. F-15E900C-BK4 ................... F-15E900C-BKBLT5 ............. F-15E-KIT-SPOOL-130MM .. F-15ELF-0000-0001 ............. F-10ELF-0000-0800 ............. F-10
ELF-0000-2400 ............. F-10ELF-PC12-FC00 ........... F-10ELF-PC12-SC00 ........... F-10ELF-PC24-LC00 ........... F-10ELF-SP12-FCPT ........... F-10ELF-SP12-SCPT ........... F-10ESTF-01TR-1RU .......... F-15ESTF-03TR-2RU .......... F-15ESTF-04TR-3RU .......... F-15ESTF-06TR-4RU .......... F-15ESTF-C012-ALC-000 .... F-15ESTF-C012-ASC-000 ... F-15ESTF-C012-UFC-000 ... F-15ESTF-C012-ULC-000 ... F-15ESTF-C012-USC-000 ... F-15ESTF-C024-ALC-000 .... F-15ESTF-C024-ASC-000 ... F-15ESTF-C024-UFC-000 ... F-15ESTF-C024-ULC-000 ... F-15ESTF-C024-USC-000 ... F-15ESTF-P012-AE2-000 .... F-15ESTF-P012-ALC-000 .... F-15ESTF-P012-ASC-000 ... F-15ESTF-P012-UE2-000 .... F-15ESTF-P012-UFC-000 ... F-15ESTF-P012-ULC-000 .... F-15ESTF-P012-USC-000 ... F-15ESTF-P024-AE2-000 .... F-15ESTF-P024-ALC-000 .... F-15ESTF-P024-ASC-000 ... F-15ESTF-P024-UE2-000 .... F-15ESTF-P024-UFC-000 ... F-15ESTF-P024-ULC-000 .... F-15ESTF-P024-USC-000 ... F-15ESTF-S012-000-000 ..... F-15ESTF-S024-000-000 ..... F-15ESTR ............................ F-15F124S-SP-M010-STPT . F-20F14-SSG-M001-0 .......... F-20HD56-4862-6161-SEN .... F-5HD56-4862-6161-SOD ... F-5HD56-4Q62-5151-SEN ... F-5HD56-4Q62-5151-SOD ... F-5HD56-4T19-6161-SEN .... F-5HDX-FL4RU-230 ............. F-5HDX-FM4RU-230 ............ F-5HDX-M4RU-190 .............. F-5HDX-M4RU-230 .............. F-5KIT-BOND ....................... F-7KIT-CLMP ........................ F-7KIT-CMHOOK ..........F-5,F-7KIT-CMHOOK3RU .......... F-7KIT-CMRHOOK ............... F-7KIT-CMRHOOK3RU ....... F-7KIT-SLEEVES ........F-7,F-15LCX-C2RU ...................... F-7LCX-C4RU ...................... F-7
LCX-C6RU ...................... F-7LCX-C8RU ...................... F-7LCX-M1RU ...................... F-6LCX-M2RU ...................... F-6LCX-M3RU ...................... F-6LCX-M4RU ...................... F-6LCX-P141S ..................... F-6LCX-S141 ....................... F-7LCX-S1RU ...................... F-7LCX-S2RU ...................... F-7LCX-S3RU ...................... F-7LCX-S4RU ...................... F-7LCX-S-HSF ..................... F-7NSFX-P012-ASC-000 ... F-13NSFX-P012-UFC-000 ... F-13NSFX-P012-USC-000 ... F-13NSFX-P024-ASC-000 ... F-13NSFX-P024-UFC-000 ... F-13NSFX-P024-USC-000 ... F-13NSFX-PO12-ACL-000 ... F-13NSFX-PO12-ULC-000 .. F-13NSFX-PO24-ALC-000 ... F-13NSFX-PO24-ULC-000 .. F-13NSFX-S012-000-000 .... F-12NSFX-S024-000-000 .... F-12NSFX-STOR ................. F-12NSRA-01TR-1RU .......... F-12NSRA-04TR-3RU .......... F-12NSRA-06TR-4RU .......... F-12NSRA-P012-ASC-000 ... F-13NSRA-P012-UFC-000 ... F-13NSRA-P012-USC-000 .. F-13NSRA-P024-ASC-000 ... F-13NSRA-P024-UFC-000 ... F-13NSRA-P024-USC-000 .. F-13NSRA-PO12-ALC-000 .. F-13NSRA-PO12-ULC-000 .. F-13NSRA-PO24-ALC-000 .. F-13NSRA-PO24-ULC-000 .. F-13NSRA-S012-000-000 .... F-12NSRA-S024-000-000 .... F-12NSRA-STOR ................. F-12NSRX-P012-ASC-000 ... F-13NSRX-P012-UFC-000 ... F-13NSRX-P012-USC-000 .. F-13NSRX-P024-ASC-000 ... F-13NSRX-P024-UFC-000 ... F-13NSRX-P024-USC-000 .. F-13NSRX-PO12-ALC-000 .. F-13NSRX-PO12-ULC-000 .. F-13NSRX-PO24-ALC-000 .. F-13NSRX-PO24-ULC-000 .. F-13NSRX-S012-000-000 .... F-12NSRX-S024-000-000 .... F-12NSRX-STOR ................. F-12WT2E-CBLX-BLK ......... F-23WT4E-CBLX-BLK ......... F-23
1.509.926.6000 :: telect.com