telecom towers trident structures pvt ltdwebsite : e-mail : [email protected]

5
Telecom Towers TRIDENT STRUCTURES PVT LTD WEBSITE : www.tridentstructures.com E-MAIL : [email protected]

Upload: hugo-reeves

Post on 22-Dec-2015

216 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Telecom Towers TRIDENT STRUCTURES PVT LTDWEBSITE :  E-MAIL : info@tridentstructures.com

Telecom Towers

TRIDENT STRUCTURES PVT LTD WEBSITE : www.tridentstructures.com E-MAIL : [email protected]

Page 2: Telecom Towers TRIDENT STRUCTURES PVT LTDWEBSITE :  E-MAIL : info@tridentstructures.com

Trident SST are used to support wide range of loading from single horn antenna to fully loaded Microwave link containing many of parabolic antennas. Every SST is designed for specific loading and wind spread tolerance depending upon the needs of the customers. Our designs provide the benefit of, easy installation. Towers are from Galvanized, painted and weathering steel capabilities.

Self Supporting Towers(SST)

TRIDENT STRUCTURES PVT LTD WEBSITE : www.tridentstructures.com E-MAIL : [email protected]

Page 3: Telecom Towers TRIDENT STRUCTURES PVT LTDWEBSITE :  E-MAIL : info@tridentstructures.com

We of-course undertake Civil Foundation, erection of towers at sites including painting.

TRIDENT STRUCTURES PVT LTD WEBSITE : www.tridentstructures.com E-MAIL : [email protected]

We make up to 100 mt Towers

Page 4: Telecom Towers TRIDENT STRUCTURES PVT LTDWEBSITE :  E-MAIL : info@tridentstructures.com

• Wind load conditions• Antenna loading• Conductor load conditions• Ice load conditions• Topography factor• Dynamic effect of wind• Lights loading• Factor of safety• Certification / Standards

requirements

Our Designs are validated by Structural Engineering Research Center (SERC), Chennai, Govt. of India; Indian Institute of Technology (IIT), Central Power Research Institute (CPRI)

TRIDENT STRUCTURES PVT LTD WEBSITE : www.tridentstructures.com E-MAIL : [email protected]

Mast and tower design requires special expertise since the structures are exposed to dynamic wind load. Towers are designed using latest software based programs taking into account various parameters under IS & TIA 22g standards.

Facility of In- house Advanced Designing based on 3 D Models

Designing

Page 5: Telecom Towers TRIDENT STRUCTURES PVT LTDWEBSITE :  E-MAIL : info@tridentstructures.com

We do undertake Civil Foundation, Erection of

towers at sites including Painting.

Exports