Page 1: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

xx

TekExpress®

SATA Compliance Automated SolutionZZZ

Printable Online Help

*P077098400*

077-0984-00

Page 2: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software
Page 3: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress®

SATA Compliance Automated SolutionZZZ

Printable Online Help

www.tektronix.com077-0984-00

Page 4: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or itssubsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.

Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in thispublication supersedes that in all previously published material. Specifications and price change privilegesreserved.

TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.

TekExpress is a registered trademark of Tektronix, Inc.

TekExpress SATA Compliance Automated Solution, 076-0362-00.

Contacting TektronixTektronix, Inc.14150 SW Karl Braun DriveP.O. Box 500Beaverton, OR 97077USA

For product information, sales, service, and technical support:In North America, call 1-800-833-9200.Worldwide, visit www.tektronix.com to find contacts in your area.

Page 5: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Table of Contents

Table of Contents

Getting help and supportRelated documentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Conventions used in help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Technical support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Getting startedInstalling the SATA software

Install the SATA software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Activate the license . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3View software version and license information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Introduction to the applicationSATA key features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Supported oscilloscopes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Supported arbitrary waveform generators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Minimum system requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Application directories and files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7File name extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Operating basicsRun the application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Exit the application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Application controls and menus

Application controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Options menu

Options menu overview .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Instrument control settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Email settings

Email Settings dialog box overview .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Configure email settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Deskew.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Application panels

Application panel overview .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Setup panel

Setup panel overview.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Set DUT parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Select tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Set acquisition parameters source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Set test notification preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

TekExpress SATA Compliance Printable Online Help i

Page 6: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Table of Contents

Configure test parametersAbout configuring test parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Configure test parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Common test parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Status panel overview .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Results panel

Results panel overview .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26View test results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27View test-related files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Plots panelPlots panel overview.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Reports panelReports panel overview .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Select report options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30View a report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Report contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Setting up and configuring testsAbout setting up tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Equipment connection setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36View connected instruments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Test setup overview .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Running testsAbout running tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Before you click Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Pre-run checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Saving and recalling test setupsTest setups overview .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Save a test setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Recall a saved test setup .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Create a new test setup based on an existing one .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

TekExpress programmatic interfaceAbout the programmatic interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Requirements for developing TekExpress client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Remote proxy object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Client proxy object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Client programmatic interface overview .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Program remote access code example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56SATA application commands

ii TekExpress SATA Compliance Printable Online Help

Page 7: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Table of Contents

SATA application commands flow.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Connect through an IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Lock the server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64Disable the popups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Set or get the DUT ID .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Set the configuration parameters for a suite or measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Query the configuration parameters for a suite or measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Select a suite. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70Select a test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Select a channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Configure the selected measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Run with set configurations or stop the run operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Handle error codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Get or set the timeout value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76Wait for the test to complete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77After the test is complete. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Save, recall, or query a saved session .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Unlock the server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84Disconnect from the server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

SATA testsSATA test definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85TSG01 - Differential Output Voltage - Option 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85TSG01 - Differential Output Voltage - Option 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85TSG02 - Rise/Fall time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85TSG03 - Differential Skew .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86TSG04 - AC Common Mode Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87TSG05 - Rise/Fall Imbalance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88TSG06 - Amplitude Imbalance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89TSG09 - Gen1 TJ at connector Clock to Data fBAUD-500 .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90TSG10 - Gen1 DJ at connector Clock to Data fBAUD-500 .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90TSG11 - Gen2 TJ at connector Clock to Data fBAUD-500 .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90TSG12 - Gen2 DJ at connector Clock to Data fBAUD-500 .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91TSG13 - Gen3 Transmit Jitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91TSG14 - Gen3 TX Maximum Differential Voltage Amplitude. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92TSG15 - Gen3 TX Minimum Differential Voltage Amplitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Eye Diagram .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92PHY01 - Unit Interval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93PHY02 - Long term Frequency Stability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93PHY03 - Spread Spectrum Modulation Frequency .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93PHY04 - Spread-Spectrum Modulation Deviation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94dF/dt Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

TekExpress SATA Compliance Printable Online Help iii

Page 8: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Table of Contents

OOB01 - Signal Detection Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

OOB02 - UI during OOB Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

OOB03 - COMINIT/RESET and COMWAKE Transmit Burst Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

OOB04 - COMINIT/RESET Transmit Gap Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

OOB05 - COMWAKE Transmit Gap Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100

OOB06 - COMWAKE Gap Detection Windows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

OOB07 - COMINIT Gap Detection Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

RSG01 - GEN1 (1.5 Gb/S) Receiver Jitter Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

RSG02 - GEN2 (3 Gb/S) Receiver Jitter Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

RSG03 - GEN3 (6 Gb/S) Receiver Jitter Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

RSG05 - Asynchronous Receiver Stress Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

RSG06 - Asynchronous Receiver Stress Test with SSC .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

RMT01 - Gen1 (1.5 Gb/S) Receiver Margin Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

RMT02 - Gen2 (3.0 Gb/S) Receiver Margin Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

RMT03 - Gen3 (6.0 Gb/S) Receiver Margin Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

Index

iv TekExpress SATA Compliance Printable Online Help

Page 9: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Getting help and support Related documentation

Related documentation

The following are available as part of the TekExpress SATA Automated Solution documentation set.

Table 1: Product documentation

Item Purpose Location

Online Help In-depth operation and UI help Application Help menu

PDF of the Online Help In-depth operation and UI help Application Help menu

Downloadable file from www.tektronix.com

xxx

See also

Technical Support (see page 2)

Conventions used in help

Online Help uses the following conventions:

The term “DUT” is an abbreviation for Device Under Test.

The terms “click” and “select” are generic terms that mean to select an item in the application userinterface (UI). You can use a mouse or the touch screen to select UI items.

TekExpress SATA Compliance Printable Online Help 1

Page 10: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Getting help and support Technical support

Technical support

Tektronix values your feedback on our products. To help us serve you better, please send us yoursuggestions, ideas, or comments on your application or oscilloscope. Contact Tektronix through mail,telephone, or the Web site. See Contacting Tektronix for more information.

When you contact Tektronix Technical Support, please include the following information (be as specific aspossible):

General information

All instrument model numbers

Hardware options, if any

Probes used

Your name, company, mailing address, phone number, FAX number

Please indicate if you would like to be contacted by Tektronix about your suggestion or comments.

Application specific information

Software version number

Description of the problem such that technical support can duplicate the problem

If possible, save the setup files for all the instruments used and the application.

If possible, save the TekExpress setup files, log.xml, *.TekX (session files and folders), and statusmessages text file.

2 TekExpress SATA Compliance Printable Online Help

Page 11: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Getting started Install the SATA software

Install the SATA software

The TekExpress SATA web installer page provides a link to the software packageTekExpress_SATA_Deployment_Package_v1.0.0.xx.exe used to install the application on a supportedoscilloscope. For a list of compatible instruments, see Supported oscilloscopes and probes (see page 5).

To download and install the files:

1. Close the TekScope application.

2. Go to the www.tek.com Web site and search for TekExpress SATA to locate the installation file.Download the file TekExpress_SATA_Deployment_Package_v1.0.0.xx.exe.

3. If you downloaded the file to a PC, copy the file to the oscilloscope.

4. Double-click the executable file to extract the installation files.

After extraction, the installer launches and the software automatically installs in the followingWindows 7 location:

C:\Program Files\Tektronix\TekExpress\TekExpress SATA

5. To run the application, open the TekScope application and select Analyze > TekExpress SATA.

See also

Minimum system requirements (see page 6)

Supported oscilloscopes and equipment (see page 5)

Activate the license

Activate the license using the Option Installation wizard on the oscilloscope. The oscilloscope Online Helphas instructions for using the Options Installation window to activate licenses for installed applications.Follow these steps to activate the TekExpress SATA license:

1. From the oscilloscope menu, click Utilities > Option Installation. The TekScope Option Installationwizard opens.

2. Press the F1 key on the oscilloscope keyboard to open the Option Installation help topic. Follow thedirections in the topic to activate the license.

See also

View software version and license information (see page 4)

TekExpress SATA Compliance Printable Online Help 3

Page 12: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Getting started View software version and license information

View software version and license information

The following instructions show how to view version and license information for the application andassociated modules such as the Programmatic Interface and the Programmatic Interface Client.

To view version information:

1. From the Options menu, select About TekExpress. The following screen appears:

To view license information:

1. In the TekScope application, select Help > About TekScope.

The Options section in the dialog box displays a list of installed options, including SATA Solutions.

2. Look in the Option Installation Key section for option key information.

See also

Activate the license (see page 3)

Options menu (see page 11)

4 TekExpress SATA Compliance Printable Online Help

Page 13: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Getting started SATA key features

SATA key features

Welcome to the TekExpress® SATA Compliance Automated Solution application (Option SATA-TSGand SATA-RSG). TekExpress SATA is based on TekExpress version 3.0 Framework, the TektronixCompliance Test Automation Framework, developed to support current and future test automation needs.It is a highly modular architecture that enables deploying automated test solutions for various serialstandards in a relatively short time. TekExpress provides a compliance test automation solution for theSerial ATA Gen 1, Gen 2, and Gen 3 standards.

Key SATA compliance testing features include:

Automated testing reduces the complexity of executing compliance tests and enables you to testdevices faster

Complete SATA Gen1, Gen2, and Gen3 Test Coverage for Hosts, Drives for i, m and u interface types

PHY Receiver Signal Requirements and Receiver Margin Test (RMT) for SATA Gen1, Gen2, andGen3

Supported oscilloscopes

The TekExpress SATA application runs on the following Tektronix oscilloscopes:

DPO/DSA/MSO71254C

DPO/DSA/MSO71604C

DPO/DSA/MSO72004C

DPO/MSO72304DX

DPO/DSA/MSO72504D/DX

DPO/DSA/MSO73304D/DX

See also

Minimum system requirements (see page 6)

Supported arbitrary waveform generators

The TekExpress SATA application supports the following Tektronix Arbitrary Waveform Generators:

TekExpress SATA Compliance Printable Online Help 5

Page 14: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Getting started Minimum system requirements

AWG7122B/C with Options 01, 06, and 08

Minimum system requirements

The following table shows the minimum system requirements for an oscilloscope to run TekExpress.

Table 2: System requirements

Oscilloscope Supported oscilloscopes (see page 5)

Arbitrary Waveform Generator Supported arbitrary waveform generators (see page 5)

Processor Same as the oscilloscope

Operating System Windows 7 64-bit

Memory Same as the oscilloscope

Hard Disk Same as the oscilloscope

Display Same as the oscilloscope

Firmware TekScope v7.1.1 and above (Windows 7)

Software Matlab Runtime engine v8.0 (Windows 7)

IronPython 2.7.3

PyVisa 1.0.0.25

On AWG, SerialXpress application Ver. 3.0 and above

Microsoft .NET 4.0 Framework

Microsoft Internet Explorer 6.0 SP1 or later

Adobe Reader 7.0 or equivalent software for viewing portable documentformat (PDF) files

DPOJET v6.1.0 and above

Other Devices Matched pair of SMA cables, one-set minimum for single lane

Microsoft compatible mouse or compatible pointing device

xxx

See also

Supported oscilloscopes (see page 5)

Supported arbitrary waveform generators (see page 5)

Equipment connection setup (see page 36)

6 TekExpress SATA Compliance Printable Online Help

Page 15: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Getting started Application directories and files

Application directories and files

The application directory and associated files are organized as follows:

The following table lists the default directory names and their usage:

Table 3: Application directories

Directory names Contains

InstallDir\TekExpress\TekExpress SATA Application and associated files

TekExpress SATA\Bin Miscellaneous SATA application libraries

TekExpress SATA\Compliance Suites Compliance-specific files

TekExpress SATA\Examples Various support files

TekExpress SATA\ICP Instrument and SATA application-specific interface libraries

TekExpress SATA\Lib Contains utility files specific to the SATA application

TekExpress SATA\Report Generator Excel Active X interface Library for Report Generation

TekExpress SATA\Tools Instrument and SATA application-specific files

TekExpress SATA\Documents Various support files

TekExpress SATA\Images Application specific images

xxx

See also

View test-related files (see page 28)File name extensions (see page 8)

TekExpress SATA Compliance Printable Online Help 7

Page 16: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Getting started File name extensions

File name extensions

The SATA application uses the following file name extensions:

File name extension Description

.TekX Saved session files. The extensions may not be displayed.

.py Test sequence files

.xml Encrypted XML files that contain test-specific configuration information

Note that the log file extension is also xml

.wfm Test waveform files

.mht Test result reports (default format)

.pdf Test result reports in PDF format

xxx

See also

Select report options (see page 30)

View test-related files (see page 28)

Application directories and files (see page 7)

8 TekExpress SATA Compliance Printable Online Help

Page 17: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Run the application

Run the application

To run the SATA application, do either of the following:

Select Analyze > TekExpress SATA from the TekScope menu.

Double-click any saved SATA session file.

When you open the application after installation, the application checks for a file called Resources.xmllocated in the C:\Users\<username>\My Documents folder. The Resources.xml file gets mappedto the X: drive when the application launches. Session files are then stored inside the X:\SATA folder.The Resources.xml file contains information about available network-connected instruments. If thisfile is not found, the application runs an instrument discovery program before launching SATA to locateavailable instruments.

If the application license was not installed using the TekScope menu Utilities > Option Installationselection, you can open the application up to 10 times in evaluation mode. Each time you open theapplication without supplying a valid license key, one of the free trials is used.

See also

Activate the license (see page 3)

Exit the application

Use the following method to exit the application:

NOTE. Using other methods to exit the application results in abnormal termination of the application.

1. Click on the application title bar.

2. Do one of the following:

If you have an unsaved session or test setup open, you are asked to save it before exiting. To saveit, click Yes. Otherwise click No. The application closes.

A message box appears asking if you really want to exit TekExpress. To exit, click Yes.

TekExpress SATA Compliance Printable Online Help 9

Page 18: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Application controls

Application controlsTable 4: Application control descriptions

Item Description

Options menu (see page 11) Opens the Options menu for access to global controls

Panels (see page 16) Visual frames with sets of related options

Command buttons Buttons that initiate an immediate action such as the Start, Stop, Pause,Continue, and Clear command buttons

Start button

Starts continuous measurement acquisition and accumulation. If prioracquired measurements have not been cleared, the new measurementsare added to the existing set.

Stop button

Stops (aborts) the current measurement acquisition.

Pause \ Continue button

Use the Pause button to temporarily interrupt the current acquisition. Whena test is paused, the button name changes to Continue.

Clear button

Clears all existing measurement results. Adding or deleting a measurement,or changing a configuration parameter of an existing measurement, alsoclears measurements. This prevents the accumulation of measurementstatistics or sets of statistics that are not coherent. This button is availableonly on the Results panel (see page 26).

Clear Log

This button is available only on the Status panel (see page 25).

Save

This button is available only on the Status panel (see page 25).

Application window move icon

Place the cursor over the three-dot pattern in the upper left corner of theapplication window. When the cursor changes to a hand, drag the windowto the desired location.

xxx

10 TekExpress SATA Compliance Printable Online Help

Page 19: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Options menu overview

Options menu overview

The Options menu is located in the upper right corner of the application.

The Options menu (see page 11) has the following selections:

Menu Function

Default Test Setup Opens an untitled test setup with defaults selected

Open Test Setup Opens a saved test setup

Save Test Setup Saves the current test setup selections

Save Test Setup As Creates a new test setup based on an existing one

Open Recent Displays a menu of recently opened test setups from which to select

Instrument Control Settings (see page 12) Shows the list of instruments connected to the test setup and allowsyou to locate and refresh connections to connected instruments

Keep On Top Keeps the TekExpress SATA utility on top of other open windowson the desktop

Email settings dialog box (see page 12) Use to configure email options for test run and results notifications

Deskew (see page 14) Loads oscilloscope channel deskew settings into the application.

Help Displays TekExpress Help

About TekExpress Displays application details such as software name, versionnumber, and copyright

Provides access to software version and license information(see page 4) for your SATA installation

Provides a link to the Tektronix Web site

xxx

Options menu

TekExpress SATA Compliance Printable Online Help 11

Page 20: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Instrument control settings

See also

Application controls (see page 10)

Instrument control settings

Use the TekExpress Instrument Control Settings dialog box to search for and list the connected resources(instruments) found on specified connections (LAN, GPIB, USB, and so on) and each instrumentsconnection information. You access this dialog box from the Options menu.

Use the Instrument Control Settings feature to and view instrument connection details. Connectedinstruments displayed here can be selected for use in the Global Settings tab in the configuration section.See step 1 of Configure Tests (see page 23) for details.

See also

View connected instruments (see page 39)

Options menu overview (see page 11)

Email Settings dialog box overview

Use the Email Settings dialog box to enable SATA to send an email message when a test completes,produces an error, or fails. Select the type of test run information to attach to the email (such as test reportsand test logs), the email message format, and the email message size limit.

Open the Email Settings dialog box from the Options menu.

NOTE. Recipient email address, sender’s address, and SMTP Server are mandatory fields.

12 TekExpress SATA Compliance Printable Online Help

Page 21: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Configure email settings

See also

Configure email settings (see page 13)

Options menu (see page 11)

Select test notification preferences (see page 22)

Configure email settings

To be notified by email when a test completes, fails, or produces an error, configure the email settings.

1. Select Options > Email Settings to open the Email settings dialog box.

2. (Required) For Recipient email Address(es), enter one or more email addresses to which to send thetest notification. To include multiple addresses, separate the addresses with commas.

3. (Required) For Sender’s Address, enter the email address used by the instrument. This address consistsof the instrument name, followed by an underscore, followed by the instrument serial number, the @symbol and then the email server used. For example: [email protected].

4. (Required) In the Server Configuration section, type the SMTP Server address of the Mail serverconfigured at the client location, and the SMTP Port number, in the corresponding fields.

If this server requires password authentication, enter a valid login name, password, and host namein the corresponding fields.

NOTE. If any of the above required fields are left blank, the settings will not be saved and emailnotifications will not be sent.

TekExpress SATA Compliance Printable Online Help 13

Page 22: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Deskew

5. In the Email Attachments section, select from the following options:

Reports: Attach the test report to the notification email.

Status Log: Attach the test status log to the notification email. If you select this option, then alsoselect whether you want to receive the full log or just the last 20 lines.

6. In the Email Configuration section:

Select the message file format to send: HTML (the default) or plain text.

Enter a maximum file size for the email message (message plus attachment files). Messages withattachments larger than this limit will not be sent. The default is 5 MB.

Enter the number in the Number of Attempts to Send field, to limit the number of attempts that thesystem makes to send a notification. The default is 1. You can also specify a timeout period.

7. Select the Email Test Results When complete or on error check box. Use this check box to quicklyenable or disable email notifications.

8. To test your email settings, click Test Email.

9. To apply your settings, click Apply.

10. Click Close when finished.

Deskew

The Deskew utility reads the instrument configuration and channel deskew settings from the connectedoscilloscope and stores them in a file. When you run a test (click the Start button), SATA resets theoscilloscope to the factory default settings, loads the instrument configuration and channel deskew settingswith the saved values, and then starts running the test session. This is to make sure that the instrument isset to a known state before each test run.

NOTE. Make sure that you run the SATA Deskew utility after you have finalized the DUT setup, oscilloscopesettings, and channel deskew values, and before you run compliance tests with that test configuration. Seeyour oscilloscope user documentation or online help for information on channel deskew procedures.

NOTE. You will need to run the Deskew utility whenever you change the oscilloscope settings or channeldeskew values for a test setup.

NOTE. SATA does not verify that the saved oscilloscope settings and deskew values are applicable to thecurrent instrument attached to the application.

14 TekExpress SATA Compliance Printable Online Help

Page 23: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Deskew

1. In the TekExpress SATA application, select Options > Deskew.

2. Select the level sensitive deskew setting:

Less than 100 mV Vertical Scale: Select this if the oscilloscope vertical setting is less than100 mV/division for the signal you are measuring.

100 mV or greater Vertical Scale: Select this if the oscilloscope vertical setting is greater than100 mV/division for the signal you are measuring.

3. Click Read Deskew/Attn. The utility stores the instrument settings and deskew settings as follows:

<100mV: C:\Program Files\Tektronix\TekExpress\TekExpress SATA\ICP\Deskew-Attenuation.txt

≥100 mV: C:\Program Files\Tektronix\TekExpress\TekExpress SATA\ICP\Deskew-Attenuation-GE100mV.txt

4. When the status in the dialog box indicates the deskew is finished, click Close.

TekExpress SATA Compliance Printable Online Help 15

Page 24: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Application panel overview

Application panel overview

Panels group related configuration, test and results settings.

The TekExpress SATA panels are:

Table 5: Application panels

Panel name Description

Setup(see page 16)

Set the DUT, test, acquisition, and report parameters.

Status(see page 25)

View the progress and analysis status of the selected tests, and view test logs.

Results(see page 26)

View a summary of test results and select results viewing preferences.

Plots(see page 28)

View plots related to RSG and RMT tests.

Reports(see page 29)

Browse for reports, save reports as specific file types, specify report naming conventions, selectreport content to include (such as summary information, detailed information, user comments,setup configuration, application configuration), and select report viewing options.

xxx

See also

Application controls (see page 10)

About setting up tests (see page 35).

Setup panel overview

The Setup panel contains sequentially ordered tabs that help guide you through a typical test setup process.

Set the DUT parameters (see page 17).

Select test(s) (see page 18).

Set lane acquisition source (see page 21).

Configure the selected tests (see page 23).

Select test notification preferences (see page 22).

16 TekExpress SATA Compliance Printable Online Help

Page 25: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Set DUT parameters

Items selected in a preceding Setup tab may change options available in the following tabs. You can switchbetween the tabs in any order to modify your test parameters.

Set DUT parameters

Use the Setup panel DUT tab to select parameters for the device under test. The settings are globaland apply to all tests for the current session. DUT settings also affect the list of available tests in theTest Selection tab.

1. Click Setup > DUT.

2. (Optional) Enter the ID for the device. The default value is DUT001. The DUT ID parameter isadded to reports.

3. (Optional) To add comments to the test report, click the note pad icon ( ) to the right of the DUTID field. Enter comment text up to 256 characters. To enable or disable displaying comments in thetest report, see Select report options (see page 30).

4. Select from the following parameters. Settings that do not apply to compliance testing cannot bechanged and are grayed out.

Table 6: DUT tab settings

Setting Description

Acquire live waveforms Acquire active signals from the oscilloscope for testing.

Use pre-recordedwaveform files

Run tests on a saved run session file. Select a run session file from the list.

View Determines where to access the test configuration settings:

Compliance: View configuration settings by clicking Setup > Test Selection >Configure

Advanced: Enables the Setup > Configuration tab in which to view configurationsettings.

Type Select the device type of either Device or Host. The test suite options are automaticallyupdated corresponding to the device selected

Suite The application allows you to select tests of transmitter or RSG-RMT to execute.

Interface Type Choose between iSATA, mSATA and uSATA. uSATA is applicable only for device type Host.

Generation Select the data rates to include in the tests

BIST-L Initialization Choose between Operation with AWG, User Defined BIST-L or Custom Utility. This choicedetermines how the DUT will be put into loopback.

xxx

See also

About setting up tests (see page 35)

TekExpress SATA Compliance Printable Online Help 17

Page 26: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Select tests

Select tests

Use the Test Selection tab to select the tests to run on the connected DUT.

18 TekExpress SATA Compliance Printable Online Help

Page 27: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Select tests

1. Click Setup > Test Selection.

2. Select the test(s) to run:

Click one or more check boxes adjacent to each test.

Click Deselect All to deselect all tests. All tests are selected by default.

Click Select Required to select all tests that are required for compliance.

Click Select All to select all tests.

3. Configure the test(s):

Click Configure to open the configuration settings for a selected test.

NOTE. The Configure button is not displayed if the View in the DUT tab is set to Advanced.

Click Schematic to display a schematic diagram that shows the DUT test setup. Use the diagramto verify the test setup before running the test.

Click Show MOI to display MOI PDF for TSG related tests.

See also

About setting up tests (see page 35)

TekExpress SATA Compliance Printable Online Help 19

Page 28: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Select tests

20 TekExpress SATA Compliance Printable Online Help

Page 29: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Set acquisition parameters source

Set acquisition parameters source

Use the Acquisitions tab to set the signal source (channel) used to acquire data. Acquisition options areavailable only when acquiring a live waveform.

1. Click Setup > Acquisitions.

2. Click the Data + (+), Data - (-) andMarker fields to select the oscilloscope channels to use forthose lanes.

3. Click on the View Probes button to view the probe configuration of each oscilloscope channel.

4. Select Show Acquire Parameters to show the acquisition parameters in the test list.

5. Select a Signal Validation parameter:

Select Prompt me if signal fails to open a dialog box when the application fails to acquire a validsignal after a specified number of retries (as set in the Configuration tab or fields). Select one ofthe three options in the dialog box:

Re-Acquire: The application attempts to re-acquire the signal.

Use Anyway: Use the acquired signal for all applicable tests.

Skip Test: Skip (ignore) any test(s) that depend on this acquisition. Skipped tests are listed inthe status panel and in the report.

Select Use signal as is - Don’t Check to skip signal validation and use the signal as-is for testing.The test results may not be as expected.

TekExpress SATA Compliance Printable Online Help 21

Page 30: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Set test notification preferences

Set test notification preferences

Use the Preferences tab to set the application to send an email when a test measurement completes:

1. Click Setup > Preferences.

2. Select the Email Test Results when complete check box in the Email Settings dialog box. ClickEmail Settings to configure the email settings (see page 13).

See also

About setting up tests (see page 35)

Select report options (see page 30)

22 TekExpress SATA Compliance Printable Online Help

Page 31: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics About configuring test parameters

About configuring test parameters

Use the configuration settings to view the measurement parameters for selected tests. How the testconfigurations are accessed depend on the View selected in the DUT tab.

If you selected Compliance View in the DUT tab, then in the Test Selection tab, select the desired testin the list and then click the Configure button.

If you selected Advanced View in the DUT tab, click the Configuration tab in the Setup panel.

See also

Configure test parameters

About running tests (see page 43)

Configure test parameters

The Configuration parameters let you set global and individual test parameters. To return to test selectionfrom the Configuration tab or panel, click the Test Selection button.

NOTE. You cannot change test parameters that are grayed out.

1. Modify Global settings (see page 23) as desired:

To select the instruments for testing, click Global Settings. In the Instruments Detected section,click in the shaded areas to activate the drop-down lists and select an instrument. If you do not seethe desired instrument in the list, refresh the list (see page 39).

2. To modify any individual test measurement settings, clickMeasurements, select the test in the treeview, and change the settings.

See also

About Setting Up Tests (see page 35)

Common test parameters

The following table lists the settings and parameters common to all tests.

TekExpress SATA Compliance Printable Online Help 23

Page 32: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Common test parameters

Table 7: Common parameters and values

Parameter type Parameter

Mode Determines whether test parameters are in compliance mode or can be edited(User Defined Mode).

Compliance: Most test parameter values cannot be edited.

User Defined: Most test parameter values can be edited.

Global Settings These settings apply to all tests selected for the current session. You canchange only some of these settings.

Scope Settings: Specifies the instrument channel to use as the source forthe trigger. This can be changed.

Channel Amplitude: The value of the amplitude to be set for the selectedchannel.

Measurements These settings apply to the test selected in the tree view of the configurationsection.

Limits Editor Shows the upper and lower limits for the applicable measurement using differenttypes of comparisons.

In Compliance Mode, you are able to view the measurement high and low limitsused for the test selected in the tree view of the Measurements tab.

When running tests in User Defined Mode, you can edit the limit settings (seepage 24) in the Limits Editor. When running tests in User Defined Mode, the cellsin the Limits Editor table are active for editing so you can change parameters.

When running tests in User Defined Mode, the cells in the Limits Editortable are active for editing so you can change parameters.

xxx

See also

Configure tests (see page 23)

24 TekExpress SATA Compliance Printable Online Help

Page 33: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Status panel overview

Status panel overview

The Status panel provides status on test acquisition and analysis (Test Status tab) and a listing of test tasksperformed (Log View tab). The application opens the Test Status tab when you start a test run. You canselect the Test Status or the Log View tab to view these items while tests are running.

The Test Status tab lists a high level status for each test.

Table 8: Test Status tab

Column Description

Test Name Name of the test

Acquire Status,Analysis Status

Status of the signal acquisition or test analysis

To be started

In progress

Testing

Completed

Aborted

xxx

The Log View tab provides a list of the actions executed during the test. Use this information to reviewor troubleshoot tests.

TekExpress SATA Compliance Printable Online Help 25

Page 34: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Results panel overview

Table 9: Log View fields

Item Description

Message History Displays all run messages with timestamp information.

Auto Scroll Sets the program to automatically scroll down the Message History window as information is addedto the log during the test.

Clear Log Clears all messages in the Message History window.

Save Saves the log file as a text file for examination. Displays a standard Save File window and savesthe status messages in the file that you specify.

xxx

See also

View test results (see page 27)

Results panel overview

When a test finishes, the application switches to the Results panel to display a summary of test results.Set viewing preferences for this panel from the Preferences menu in the upper right corner. Viewingpreferences include showing whether a test passed or failed, summary results or detailed results, andenabling wordwrap. For information on using this panel, see View test results (see page 27).

26 TekExpress SATA Compliance Printable Online Help

Page 35: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics View test results

View test results

When a test finishes, the application switches to the Results panel (see page 26), which displays asummary of test results. The Overall Test Result is displayed at the top left of the Results table. If all ofthe tests for the session pass, the overall test result will be Pass. If one or more tests fail, the overall testresult will show Fail.

Each test result occupies a row in the Results table. By default, results are displayed in summary formatwith the measurement details collapsed and with the Pass/Fail column visible. Change the view in thefollowing ways:

To expand all tests listed, select View Results Details from the Preferences menu in the upper rightcorner.

To expand and collapse tests, click the plus and minus buttons.

To collapse all expanded tests, select Preferences > View Results Summary.

To remove or restore the Pass/Fail column, select Preferences > Show Pass/Fail.

To enable or disable the wordwrap feature, select Preferences > Enable Wordwrap.

TekExpress SATA Compliance Printable Online Help 27

Page 36: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics View test-related files

To expand the width of a column, place the cursor over the vertical line that separates the columnfrom the column to the right. When the cursor changes to a double-ended arrow, hold down the mousebutton and drag the column to the desired width.

To sort the test information by column, click the column head. When sorted in ascending order, asmall up arrow is displayed. When sorted in descending order, a small down arrow is displayed.

To clear all test results displayed, click Clear.

See also

View a report (see page 31)

View test-related files

Files related to tests are stored in the My TekExpress\SATA folder. In the SATA folder, each test setuphas a test setup file and a test setup folder, both with the test setup name. The test setup file is preceded bythe SATA icon and usually has no visible file extension.

Inside the test setup folder is another folder named for the DUT ID used in the test sessions. The defaultis DUT001.

Inside the DUT001 folder are the session folders and files. Each session has a folder and file pair, bothnamed for the test session using the naming convention (date)_(time). Each session file is stored outsideits matching session folder.

The first time you run a new, unsaved session, the session files are stored in the Untitled Session

folder located at ..\My TekExpress\SATA. When you name and save the session, the files are placed ina folder with the name that you specify.

See also

File name extensions (see page 8)

Plots panel overview

Use the Plots panel to display plots of RSG and RMT tests.

28 TekExpress SATA Compliance Printable Online Help

Page 37: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Reports panel overview

Reports panel overview

Use the Reports panel to open reports, name and save reports, select report content to include, and selectreport viewing options.

For information on setting up reports, see Select report options (see page 30). For information on viewingreports, see View the report (see page 31).

TekExpress SATA Compliance Printable Online Help 29

Page 38: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Select report options

Select report options

Use the Reports panel (see page 29) to select which test information to include in the report, and the namingconventions to use for the report. For example, always give the report a unique name or select to have thesame name increment each time you run a particular test. Generally, you would select report options beforerunning a test or when creating and saving test setups. Report settings are included in saved test setups.

In the Reports panel, select from the following options:

Table 10: Report options

Setting Description

Generate NewReport

Creates a new report.

Replace current testvalues with the newresults

Replaces the previous test results with the latest test results. Newly added tests results areappended to the end of the report.

Append to PreviousReport

Appends the latest test results to the end of the current test results report.

Report Name Displays the name and location from which to open a report. The default location is at \MyTekExpress\SATA\Untitled Session. The report file in this folder gets overwritten each time you runa test unless you specify a unique name or select to auto increment the report name.

Change the report name or location.

Do one of the following:

In the Report Name field, type over the current folder path and name.

Double-click in the Report Name field. Make selections from the popupkeyboard and then click the Enter button.

Be sure to include the entire folder path, the file name, and the file type. For example: C:\Documentsand Settings\your user name\My Documents\My TekExpress\SATA\DUT001_Test_211.mht.

NOTE. You cannot change the file location using the Browse button.

Open an existing report.

Click Browse, locate and select the report file and then click View at the bottom of the panel.

Save As Type Saves a report in the specified file type. Lists supported file types to choose from.

NOTE. If you select a file type different from the default, be sure to change the report file nameextension in the Report Name field to match.

Auto increment reportname if duplicate

Sets the application to automatically increment the name of the report file if the application finds afile with the same name as the one being generated. For example: DUT001, DUT002, DUT003.This option is enabled by default.

Include Pass/FailResults Summary

Sets the application to include the color block labeled Test Result (indicating whether the testpassed or failed) in the report. For details, see Report Contents in View a Report (see page 31).

30 TekExpress SATA Compliance Printable Online Help

Page 39: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics View a report

Table 10: Report options (cont.)

Setting Description

Include DetailedResults

Sets the application to include parameter limits, execution time, and test-specific commentsgenerated during the test.

Include Plot Images Sets the application to include plotted diagrams.

Include SetupConfiguration

Sets the application to include information about hardware and software used in the test in thesummary box at the top of the report. Information includes: the oscilloscope model and serialnumber, probe model and serial number, the oscilloscope firmware version, SPC and factorycalibration status, and software versions for applications used in the measurements.

Include CompleteApplicationConfiguration

Sets the application to include a table listing general, common, and acquired parameters usedin the test. This option is disabled by default.

Include UserComments

Select to include any comments about the test that you or another user added in the DUT tabof the Setup panel. Comments appear in the Comments section under the summary box at thebeginning of each report.

View Report AfterGenerating

Automatically opens the report in your Web browser when the test completes. This option isselected by default.

xxx

See also

View a report (see page 31)

About setting up tests (see page 35)

View a report

The application automatically generates a report when test analysis is completed and displays the reportin your default Web browser (unless you cleared the View Report After Generating check box in theReports panel before running the test). If you cleared this check box, or if you want to view a differenttest report, do the following:

1. Click the Reports > Browse button and locate and select the report file to view.

NOTE. If you did not save the test setup after running the test and you either closed the application oryou ran another test, the report file was not saved.

2. At the bottom of the Reports panel, click View.

For information on changing the file type, file name, and other report options, see Select Report Options(see page 30).

TekExpress SATA Compliance Printable Online Help 31

Page 40: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Report contents

Report contents

A report shows specified test details, as defined in the Reports panel.

Setup Configuration Information

Setup configuration information is listed in the summary box at the top of the report. This informationincludes the oscilloscope model and serial number, probe model and serial number, and software versions.To exclude this information from the report, clear the Include Setup Configuration check box in theReports panel before running the test.

User Comments

If you selected to include comments in the test report, any comments you added in the DUT tab of theSetup panel appear in the Comments section directly below the summary box.

Test results

This table lists the tests results. The contents of this table depend on the selections made in the Reportspanel before running the test (Include Pass/Fail Results Summary, Include User Comments, IncludeDetailed Results, Include Complete Application Configuration, and so on).

If Include Plots Images is selected, then measurement waveform plots are shown below the test resultstable.

32 TekExpress SATA Compliance Printable Online Help

Page 41: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Report contents

TekExpress SATA Compliance Printable Online Help 33

Page 42: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Operating basics Report contents

See also

View test results (see page 27)

View test-related files (see page 28)

34 TekExpress SATA Compliance Printable Online Help

Page 43: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Setting up and configuring tests About setting up tests

About setting up tests

Set up tests using the tabs in the Setup panel. Settings in the DUT tab use a top-down, left-to-right logicflow, so that any parameter that affects or acts as a filter for other parameters appears either to the top of orto the left of the affected parameters.

Tests are saved when you save a test setup. To avoid overwriting test results, remember to assign a uniquename to the test either before running it or immediately after.

See also

About test setups (see page 47)

Before you click Start (see page 43)

About running tests (see page 43)

TekExpress SATA Compliance Printable Online Help 35

Page 44: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Setting up and configuring tests Equipment connection setup

Equipment connection setup

The following diagrams shows how to connect the DUT to the oscilloscope for all the SATA measurements.

Device connection diagrams

36 TekExpress SATA Compliance Printable Online Help

Page 45: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Setting up and configuring tests Equipment connection setup

TekExpress SATA Compliance Printable Online Help 37

Page 46: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Setting up and configuring tests Equipment connection setup

38 TekExpress SATA Compliance Printable Online Help

Page 47: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Setting up and configuring tests View connected instruments

See also

Minimum system requirements (see page 6)View connected instruments (see page 39)About setting up tests (see page 35)

View connected instruments

Use the Instrument Control Settings dialog box to view or search for connected instruments required forthe tests. The application uses TekVISA to discover the connected instruments.

To refresh the list of connected instruments:

TekExpress SATA Compliance Printable Online Help 39

Page 48: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Setting up and configuring tests View connected instruments

1. From the Options menu, select Instrument Control Settings.

2. In the Search Criteria section of the Instrument Control Settings dialog box, select the connectiontypes of the instruments to search for.

Instrument search is based on the VISA layer but different connected cables determine the resourcetype, such as LAN, GPIB, and USB. For example, if you choose LAN, the search will include allthe instruments supported by TekExpress that are communicating over the LAN. If the search doesnot find any instruments that match a selected resource type, a message appears telling you that nosuch instruments were found.

3. Click Refresh. TekExpress searches for connected instruments.

4. After discovery, the dialog box lists the instrument-related details based on the search criteria youselected. For example, if you selected LAN and GPIB as the search criteria, the application checks forthe availability of instruments over LAN, then GPIB.

The details of the instruments are displayed in the Retrieved Instruments table. The time and date ofinstrument refresh is displayed in the Last Updated field.

See also

Configure Tests (see page 23)

Equipment Setup (see page 36)

40 TekExpress SATA Compliance Printable Online Help

Page 49: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Setting up and configuring tests Test setup overview

Test setup overview

A test setup includes configuration parameters and report options. Use the options in the Setup panel andReports panel (see page 29) to select and configure tests.

1. Set the DUT parameters (see page 17).

2. Select one or more tests (see page 18).

3. Configure tests (see page 23).

4. Select test notification preferences (see page 22).

5. Select report options (see page 30).

See also

About test Setups (see page 47)

Pre-run checklist (see page 45)

Before you click Start (see page 43)

About running tests (see page 43)

TekExpress SATA Compliance Printable Online Help 41

Page 50: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Setting up and configuring tests Test setup overview

42 TekExpress SATA Compliance Printable Online Help

Page 51: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Running tests About running tests

About running tests

After selecting and configuring the test, review the pre-run checklist (see page 45) and then click Start torun the tests. While tests are running, you cannot access the Setup or Reports panels. To monitor the testprogress, switch back and forth between the Status panel and the Results panel.

The application displays a report when the tests are complete. While the tests are running, otherapplications may display windows in the background. The TekScope application takes precedence overother applications, but you can switch to other applications by using the Alt + Tab key combination. Tokeep the TekExpress SATA application on top, select Keep On Top from the SATA Options menu.

See also

About Configuring Tests (see page 23)

About Setting Up Tests (see page 35)

Before You Click Start (see page 43)

Before you click Start

Before you run tests for the first time, do the following:

1. Understand where your test files are stored on the instrument.

After you install and launch TekExpress SATA, it creates the following folders on the oscilloscope:

\My Documents\My TekExpress\SATA

\My Documents\My TekExpress\SATA\Untitled Session

Every time you launch TekExpress SATA, an Untitled Session folder is created in theSATA folder. The Untitled Session folder is automatically deleted when you exit theSATA application.

CAUTION. Do not directly edit or modify any of the session files or folders because this may result inloss of data or corrupted session files. Each session has multiple files associated with it. When yousave a session, the application creates a .TekX file, and a folder named for the session that containsassociated files, on the oscilloscope X: drive.

2. Map the shared My TekExpress folder as X: (X drive) on all instruments used in test setup runningMicrosoft Windows Operating System.

The My TekExpress folder has the shared name format <domain><user ID>My TekExpress.Or, if the instrument is not connected to a domain, then the shared name format is <instrument

TekExpress SATA Compliance Printable Online Help 43

Page 52: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Running tests Before you click Start

name><user ID>My TekExpress. This shared folder is used to save the test session files and isused during any other file transfer operations.

NOTE. If the X: drive is mapped to any other shared folder, the application will display a warning messageasking you to disconnect the X: drive manually.

3. Make sure that the My TekExpress folder has read and write access and that the contents are not setto be encrypted:

a. Right-click the folder and select Properties.

b. Select the General tab and then click Advanced.

c. In the Advanced Attributes dialog box, make sure that the option Encrypt contents to securedata is NOT selected. Example

4. Review the pre-run checklist (see page 45) before you run a test.

See also

View Test-Related Files (see page 28)

Application Directories and Usage (see page 7)

File Name Extensions (see page 8)

44 TekExpress SATA Compliance Printable Online Help

Page 53: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Running tests Pre-run checklist

Pre-run checklist

Do the following before you click Start to run a test. If this is the first time you are running a test for asetup, refer to the information in Before You Click Start (see page 43).

On the oscilloscope:

Make sure that all the required instruments are properly warmed up.

Perform Signal Path Compensation (SPC).

a. On the oscilloscope main menu, select the Utilities menu.

b. Select Instrument Calibration and run the SPC utility..

Perform deskew on any cables.

In the SATA application:

1. Verify that the application is able to find the instrument. If it cannot, perform a search for connectedinstruments (see page 39).

a. Select Setup > Test Selection. Select any test and then click Configure.

b. In the Configuration section, click Global Settings.

c. In the Instruments Detected section, click the drop-down arrow to the right of the listedinstruments and make sure that the instrument is listed.

2. Run the Deskew utility (Options > Deskew).

See also

Equipment Connection Setup (see page 36)

TekExpress SATA Compliance Printable Online Help 45

Page 54: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Running tests Pre-run checklist

46 TekExpress SATA Compliance Printable Online Help

Page 55: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Saving and recalling test setups Test setups overview

Test setups overview

A test setup file contains the oscilloscope connection and setting information, general parameters,measurement limits, test selections, and other settings for the current application configuration. Thisinformation is saved to a file under the setup name. Use a saved test setup to quickly load and run atest without having to do any other setup except ensuring that the correct oscilloscope is connected andaccessible by SATA.

See also

About setting up tests (see page 35)

Save a test setup (see page 47)

Recall a saved test setup (see page 48)

Create a new test setup based on an existing one (see page 48)

Save a test setup

Save a test setup before or after running a test using the parameters you want saved. Create a new testsetup from any open setup or from the default setup. When you select the default test setup, all applicationsettings are returned to their defaults.

The following instructions start from the default test setup:

1. Select Options > Default Test Setup.

2. Select Setup and set required options and parameters in the tabs (DUT, Test Selection, and so on).

3. Select Reports and set your report options (see page 30).

4. Click Start to run the test and verify that it runs correctly and captures the information you want. If itdoes not, edit the parameters and repeat this step until the test runs to your satisfaction.

5. Select Options > Save Test Setup. Enter the file name for the setup file. The application savesthe file to X:\SATA\<session_name>.

See also

About setting up tests (see page 35)

About configuring tests (see page 23)

Test setup overview (see page 41)

TekExpress SATA Compliance Printable Online Help 47

Page 56: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Saving and recalling test setups Recall a saved test setup

Recall a saved test setup

To recall a saved test setup:

1. Select Options > Open Test Setup.

2. Select the setup from the list and click Open.

See also

Test setups overview (see page 47)

Create a new test setup based on an existing one (see page 48)

Create a new test setup based on an existing one

Use this procedure to create a variation on a test setup without having to create the entire setup from thebeginning.

1. Select Options > Open Test Setup.

2. Select a setup from the list and then click Open.

3. Use the Setup and Reports panels to modify the parameters to meet your testing requirements.

4. Select Options > Save Test Setup As.

5. Enter a test setup name and click Save.

See also

Test setups overview (see page 47)

48 TekExpress SATA Compliance Printable Online Help

Page 57: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface About the programmatic interface

About the programmatic interface

The Programmatic interface allows you to seamlessly integrate the TekExpress test automation applicationwith the high-level automation layer. This also allows you to control the state of the TekExpressapplication running on a local or a remote computer.

For simplifying the descriptions, the following terminologies are used in this section:

TekExpress Client: A high-level automation application that communicates with TekExpress usingTekExpress Programmatic Interface.

TekExpress Server: The TekExpress application when being controlled by TekExpress Client.

TekExpress leverages .Net Marshalling to enable the Programmatic Interface for TekExpress Client.TekExpress provides a client library for TekExpress clients to use the programmatic interface. TheTekExpress client library is inherited from .Net MarshalByRef class to provide the proxy object for theclients. The TekExpress client library maintains a reference to the TekExpress Server and this referenceallows the client to control the server state.

See also

Requirements for Developing TekExpress Client (see page 50)

Remote Proxy Object (see page 51)

Client Proxy Object (see page 51)

TekExpress SATA Compliance Printable Online Help 49

Page 58: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Requirements for developing TekExpress client

Requirements for developing TekExpress client

While developing the TekExpress Client, use the TekExpressClient.dll. The client can be a VB .Net, C#.Net, TestStand or Web application. The examples for interfaces in each of these applications are in theSamples folder.

References required

TekExpressClient.dll has an internal reference to IIdlglib.dll and IRemoteInterface.dll.

IIdlglib.dll has a reference to TekDotNetLib.dll.

IRemoteInterface.dll provides the interfaces required to perform the remote automations. It is aninterface that forms the communication line between the server and the client.

IIdlglib.dll provides the methods to generate and direct the secondary dialog messages at the client-end.

NOTE. The end-user client application does not need any reference to the above mentioned DLL files.It is essential to have these DLLs (IRemoteInterface.dll, IIdlglib.dll and TekDotNetLib.dll) in the samefolder as that of TekExpressClient.dll.

Required steps for a client

The following steps are used by the client to programmatically control the server usingTekExpressClient.dll:

Develop a client UI to access the interfaces exposed through the server. This client loadsTekExpressClient.dll to access the interfaces. After TekExpressClient.dll is loaded, the clientUI can call the specific functions to run the operations requested by the client. When the client is up andrunning, it does the following to run a remote operation:

1. To connect to the server, the client provides the IP address of the PC where the server is running.

2. The client locks the server application to avoid conflict with any other Client that may try to controlthe server simultaneously. “Lock” would also disable all user controls on the server so that serverstate cannot be changed by manual operation.

If any other client tries to access a server that is locked, it will receive a notification that the serveris locked by another client.

3. When the client has connected to and locked the server, the client can access any of the programmaticcontrols needed to run the remote automations.

4. After the client operations finish, the client unlocks the server.

See also

SATA application commands flow (see page 58)

50 TekExpress SATA Compliance Printable Online Help

Page 59: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Remote proxy object

Remote proxy object

The server exposes a remote object to let the remote client access and perform the server-side operationsremotely. The proxy object is instantiated and exposed at the server-end through marshalling.

The following is an example:

RemotingConfiguration.RegisterWellKnownServiceType (typeof (TekExpressRe-

moteInterface), “TekExpress Remote interface”, WellKnownObjectMode.Singleton);

This object lets the remote client access the interfaces exposed at the server side. The client gets thereference to this object when the client gets connected to the server.

For example,

//Get a reference to the remote object

remoteObject = (IRemoteInterface)Activator.GetObject(typeof(IRemoteInterface),

URL.ToString());

Client proxy object

Client exposes a proxy object to receive certain information.

TekExpress SATA Compliance Printable Online Help 51

Page 60: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Client proxy object

For example,

//Register the client proxy object

WellKnownServiceTypeEntry[] e = RemotingConfiguration.GetRegisteredWell-

KnownServiceTypes();

clientInterface = new ClientInterface();

RemotingConfiguration.RegisterWellKnownServiceType(typeof(ClientInterface),

“Remote Client Interface”, WellKnownObjectMode.Singleton);

//Expose the client proxy object through marshalling

RemotingServices.Marshal(clientInterface, "Remote Client Inteface");

The client proxy object is used for the following:

To get the secondary dialog messages from the server.

To get the file transfer commands from the server while transferring the report.

Examples

clientObject.clientIntf.DisplayDialog(caption, msg,iconType, btnType);

clientObject.clientIntf.TransferBytes(buffer, read, fileLength);

For more information, click the following links:

Secondary Dialog Message Handling

The secondary dialog messages from the Secondary Dialog library are redirected to the client-end when aclient is performing the automations at the remote end.

In the secondary dialog library, the assembly that is calling for the dialog box to be displayed is checkedand if a remote connection is detected, the messages are directed to the remote end.

File Transfer Events

52 TekExpress SATA Compliance Printable Online Help

Page 61: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Client programmatic interface overview

When the client requests the transfer of the report, the server reads the report and transfers the file bycalling the file transfer methods at the client-end.

Client programmatic interface overview

The following is an overview of the client programmatic interface:

Process flowchart

TekExpress SATA Compliance Printable Online Help 53

Page 62: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Client programmatic interface overview

54 TekExpress SATA Compliance Printable Online Help

Page 63: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Client programmatic interface overview

1. Connect to a server or remote object using a programmatic interface.

2. Get the client ID that is created when connecting to the remote object. This client ID is one of therequired parameters to communicate with the server.

NOTE. The server identifies the client with this ID only and rejects any request if the ID is invalid.

3. Lock the server for further operations. This disables the application interface.

NOTE. You can get values from the server or set values from the server to the client only if the applicationis locked.

4. Register for receiving notifications on status change events on the server. To register you need to givea handler as a parameter. For details, see Handler of Status Change Notification (see page 55).

NOTE. Whenever there is a change in the status of the server, all the clients registered with the serverreceive a notification from the server.

5. Select the tests to run through the programmatic interface.

6. Set the necessary parameters for each test.

7. Run the tests.

8. Poll for the status of the application.

NOTE. Skip this step if you are registered for the status change notification and the status is Ready.

9. After completing the tests, get the results.

10. Create a report or display the results and verify or process the results.

11. Unlock the server after completing all the tasks.

12. Disconnect from the remote object.

Handler of Status Change Notification

1. Get the status. If the status is Wait or Error, get the information that contains the title, messagedescription, and the expected responses for the status.

2. Perform the actions based on the status information.

3. Set the response as expected.

TekExpress SATA Compliance Printable Online Help 55

Page 64: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Program remote access code example

See also

SATA application commands flow (see page 58)

Program remote access code example (see page 56)

Program remote access code example

This code example shows how to communicate between a remote PC and TekExpress SATA.

Table 11: Remote access code example

Task Code

Start theapplication

Connect throughan IP address.

m_Client.Connect("localhost") 'True or False

clientID = m_Client.getClientID

Lock the server m_Client.LockServer(clientID)

Disable thePopups

m_Client.SetVerboseMode(clientID, false)

Set the DUT ID m_Client.SetDutId(clientID, "DUT_Name")

Select a test returnval=mClient.SelectTest(clientID, "Device", "Transmitter",

"TSG13-Gen3 Transmit Jitter", True)

Set GeneralParameter

returnval=mClient.SetGeneralParameter(clientID,"Device","Transmit-

ter","","BIST-L Initialization$User Defined BIST-L pattern")

Set Acquireparameters

returnval=mClient.SetAcquireParameter(clientID, "Device",

"Transmitter", "TSG13-Gen3 Transmit Jitter", "Record Length

(M)$10")

Set Analyzeparameter

returnval=mClient.SetAnalyzeParameter(clientID, "Device",

"Transmitter", "TSG13-Gen3 Transmit Jitter", "PLL model type$TWO")

Run with setconfigurations

m_Client.Run(clientID)

Wait for the test tocomplete.

Do

Thread.Sleep(500)

m_Client.Application_Status(clientID)

Select Case status

Case "Wait"

Case “Error"

Get the currentstate information

mClient.GetCurrentStateInfo(clientID, WaitingMsbBxCaption,

WaitingMsbBxMessage, WaitingMsbBxButtontexts)

Send theresponse

mClient.SendResponse(clientID, WaitingMsbBxCaption, WaitingMsb-

BxMessage, WaitingMsbBxResponse)

End Select

Loop Until status = "Ready"

56 TekExpress SATA Compliance Printable Online Help

Page 65: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Program remote access code example

Table 11: Remote access code example (cont.)

Task Code

Save results 'Save all results values from folder for current run

m_Client.TransferResult(clientID, logDirname)

Unlock the server m_Client.UnlockServer(clientID)

Disconnect fromserver

m_Client.Disconnect()

Exit theapplication

xxx

TekExpress SATA Compliance Printable Online Help 57

Page 66: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface SATA application commands flow

SATA application commands flow

Click a client action link to see the associated command name, description, parameters, return value,and an example.

Connect through an IP address (see page 63)

Lock the server (see page 64)

Disable the popups (see page 65)

Set or get the DUT ID (see page 66)

Set the configuration parameters for a suite or measurement (see page 67)

Query the configuration parameters for a suite or measurement (see page 69)

Select a test (see page 71)

Select a suite (see page 70)

Select a channel (see page 72)

Configure the selected measurement (see page 73)

Run with set configurations or stop the run operation (see page 74)

Handle error codes (see page 75)

Get or set the timeout value (see page 76)

Wait for the test to complete (see page 77)

After the test is complete (see page 79)

Save, recall, or query a saved session (see page 83)

Unlock the server (see page 84)

Disconnect from the server (see page 84)

string id

Name Type Direction Description

id string IN Identifier of the client performing theremote function

xxx

Ready: Test configured and ready to start

Running: Test running

Paused: Test paused

Wait: A popup that needs your inputs

Error: An error is occurred

58 TekExpress SATA Compliance Printable Online Help

Page 67: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface SATA application commands flow

string dutName

Name Type Direction Description

dutName string IN The new DUT ID of the setup

xxx

out bool saved

Name Type Direction Description

saved bool OUT Boolean representing whether thecurrent session is saved

xxx

This parameter is used as a check in SaveSession() and SaveSessionAs() functions.

string ipAddress

Name Type Direction Description

ipAddress string IN The ip address of the server to which theclient is trying to connect. This is required toestablish the connection between the serverand the client.

xxx

out string clientID

Name Type Direction Description

clientid string OUT Identifier of the client that is connected to theserver

clientId = unique number + ipaddress of theclient. For example, 1065–192.157.98.70

xxx

NOTE. If the dutName parameter is null, the client is prompted to provide a valid DUT ID.

NOTE. The server must be active and running for the client to connect to the server. Any number ofclients can be connected to the server at a time.

NOTE. When the client is disconnected, it is unlocked from the server and then disconnected. The idis reused.

TekExpress SATA Compliance Printable Online Help 59

Page 68: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface SATA application commands flow

string dutId

Name Type Direction Description

dutId string OUT The DUT ID of the setup

xxx

The dutId parameter is set after the server processes the request.

string device

Name Type Direction Description

device string IN Specifies the name of the device

xxx

string suite

Name Type Direction Description

suite string IN Specifies the name of the suite

xxx

string test

Name Type Direction Description

test string IN Specifies the name of the test toobtain the pass or fail status

xxx

string parameterString

Name Type Direction Description

parameterString string IN Specifies the string value of theparameter that is being set

xxx

int rowNr

Name Type Direction Description

rowNr int IN Specifies the zero based row index ofthe sub-measurement for obtainingthe result value

xxx

NOTE. When the client tries to lock a server that is locked by another client, the client gets anotification that the server is already locked and it must wait until the server is unlocked. If the clientlocks the server and is idle for a certain amount of time then the server is unlocked automaticallyfrom that client.

60 TekExpress SATA Compliance Printable Online Help

Page 69: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface SATA application commands flow

out string[] status

Name Type Direction Description

status string array OUT The list of status messages generatedduring the run

xxx

string name

Name Type Direction Description

name string IN The name of the session beingrecalled

xxx

The name parameter cannot be empty. If it is empty, the client is prompted to provide a valid name.

NOTE. When the run is performed, the status of the run is updated periodically using a timer.

string name

Name Type Direction Description

name string IN The name of the session being saved

xxx

The name parameter cannot be empty. If it is empty, the client is prompted to provide a valid name.

Once the session is saved under ‘name’ you cannot use this method to save the session in a differentname. Use SaveSessionAs instead.

string name

Name Type Direction Description

name string IN The name of the session beingrecalled

xxx

The same session is saved under different names using this method. The name parameter cannot beempty. If it is empty, the client is prompted to provide a valid name.

bool isSelected

Name Type Direction Description

isSelected bool IN Selects or deselects a test

xxx

TekExpress SATA Compliance Printable Online Help 61

Page 70: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface SATA application commands flow

string time

Name Type Direction Description

time string IN The time in secondsthat refers to the timeoutperiod

xxx

The time parameter gives the timeout period, which is the time the client is allowed to be locked andidle. After the timeout period if the client is still idle, it gets unlocked.

The time parameter should be a positive integer; otherwise, the client is prompted to provide avalid timeout period.

bool_verbose

Name Type Direction Description

_verbose bool IN Specifies whether the verbose modeshould be turned ON or OFF

xxx

NOTE. When the session is stopped, the client is prompted to stop the session and is stopped atthe consent.

string filePath

Name Type Direction Description

filePath string IN The location where the report mustbe saved in the client

xxx

NOTE. If the client does not provide the location to save the report, the report is saved atC:\ProgramFiles.

NOTE. When the client is disconnected, the client is unlocked automatically.

out string WaitingMsbBxCaption

Name Type Direction Description

caption string OUT The wait state or error state message sent toyou

xxx

62 TekExpress SATA Compliance Printable Online Help

Page 71: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Connect through an IP address

out string WaitingMsbBxMessage

Name Type Direction Description

message string OUT The wait state/error state message sent to you

xxx

out string[] WaitingMsbBxButtontexts

Name Type Direction Description

buttonTexts string array OUT An array of strings containing thepossible response types that you cansend

xxx

string WaitingMsbBxResponse

Name Type Direction Description

response string IN A string containing the responsetype that you can select (it must beone of the strings in the string arraybuttonTexts)

xxx

out string clientID

Name Type Direction Description

clientID string OUT Identifier of the client that is connected to theserver

clientID = unique number + ipaddress of theclient. For example, 1065–192.157.98.70

xxx

Connect through an IP addressCommand name Parameters Description Return value Example

Connect() stringipAddress (seepage 59)

out stringclientID (seepage 59)

This methodconnects the clientto the server.Note (see page 59)

The client providesthe IP addressto connect to theserver.

The serverprovides a uniqueclient identificationnumber whenconnected to it.

Return value iseither True orFalse

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as boolean

returnval = m_Client.Con-nect(ipaddress,m_clientID)

xxx

TekExpress SATA Compliance Printable Online Help 63

Page 72: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Lock the server

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

Lock the serverCommand name Parameters Description Return value Example

LockSession() string clientID(see page 63)

This method locksthe server.Note (see page 60)

The client mustcall this methodbefore runningany of the remoteautomations. Theserver can belocked by only oneclient.

String value thatgives the statusof the operationafter it has beenperformed

The return valueis "SessionLocked...” onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval =m_Client.LockServer(clientID)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

64 TekExpress SATA Compliance Printable Online Help

Page 73: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Disable the popups

Disable the popups

Use these commands to disable popup messages that require user intervention.

Command name Parameters Description Return value Example

SetVerboseMode() string clientID(see page 63)

bool _verbose(see page 62)

This method setsthe verbose modeto either true orfalse.

When the valueis set to true, anymessage boxesthat appear duringthe applicationwill be routed tothe client machinethat is controllingTekExpress.

When the value isset to false, all themessage boxesare shown on theserver machine.

String that givesthe status ofthe operationafter it has beenperformed

When Verbosemode is set totrue, the returnvalue is “Verbosemode turned on.All dialog boxeswill be shown toclient”.

When Verbosemode is set tofalse, the returnvalue is “Verbosemode turned off.All dialog boxeswill be shown toserver”.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

Verbose mode is turned on

return=m_Client.SetVerbose-Mode(clientID, true)

Verbose mode is turned off

returnval=m_Client.SetVer-boseMode(clientID, false)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

TekExpress SATA Compliance Printable Online Help 65

Page 74: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Set or get the DUT ID

Set or get the DUT IDCommand name Parameters Description Return value Example

SetDutId() string clientID(see page 63)

string dutName(see page 59)

This methodchanges the DUTID of the setup.The client mustprovide a validDUT ID.

String that givesthe status ofthe operationafter it has beenperformed

Return valueis “DUT IdChanged” onsuccess

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

return=m_Client.SetDutId(clien-tID,desiredDutId)Note (see page 59)

GetDutId() string clientID(see page 63)

string dutId (seepage 60)

This method getsthe DUT ID of thecurrent setup.

String that givesthe status ofthe operationafter it has beenperformed

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

return=m_Client.GetDutid(clien-tID, out DutId)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

66 TekExpress SATA Compliance Printable Online Help

Page 75: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Set the configuration parameters for a suite or measurement

Set the configuration parameters for a suite or measurementCommand name Parameters Description Return value Example

SetGeneralParam-eter

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This methodsets the numberof video lanesfor the selectedmeasurement.

NOTE. Use thiscommand to selecta lane, channel, orsource type.

String that givesthe status ofthe operationafter it has beenperformed

The returnvalue is "" (anempty String) onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

Select channel example

SetAnalyzeParam-eter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This method setsthe configurationparameters in theAnalyze panel ofthe ConfigurationPanel dialog boxfor a suite ormeasurement.

String that givesthe status ofthe operationafter it has beenperformed

The returnvalue is "" (anempty String) onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

SetAcquireParame-ter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This method setsthe configurationparameters in theAcquire panel ofthe ConfigurationPanel dialog boxfor a suite ormeasurement.

String that givesthe status ofthe operationafter it has beenperformed

The returnvalue is "" (anempty String) onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnVal = remoteObject.Se-tAcquireParameter(id, device,suite, test, parameterString)

if ((OP_STATUS)

returnVal !=OP_STATUS.SUCCESS)

return CommandFailed(return-Val)

xxx

TekExpress SATA Compliance Printable Online Help 67

Page 76: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Set the configuration parameters for a suite or measurement

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

Set clock edge example

returnval=mClient.SetAnalyzeParameter(clientID, "Device", "Transmitter", "5.3.9 - Random Jitter(RJ)", "Clock Edge$RISE")

68 TekExpress SATA Compliance Printable Online Help

Page 77: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Query the configuration parameters for a suite or measurement

Query the configuration parameters for a suite or measurement

Command name Parameters Description Return value Example

GetGeneralParam-eter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This methodgets the generalconfigurationparametersfor a suite ormeasurement.

The return valueis the generalconfigurationparameter fora specified suiteor measurementthat is set.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

Query status example (seepage 79)

GetAnalyzeParam-eter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This method getsthe configurationparameters setin the Analyzepanel of theConfigurationPanel dialog boxfor a specified suiteor measurement.

The returnvalue is theconfigurationparameter setin the Analyzepanel of theConfigurationPanel dialogbox for aspecified suiteor measurement.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

GetAcquireParame-ter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This method getsthe configurationparameters set inthe Acquire panelfor a specified suiteor measurement.

The returnvalue is theconfigurationparameter setin the Acquirepanel for aspecified suiteor measurement.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

TekExpress SATA Compliance Printable Online Help 69

Page 78: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Select a suite

Query parameter example

returnval=mClient.GetAnalyzeParameter(clientID, " Device", "Transmitter", "TSG13-Gen3Transmitter Jitter", "Clock Edge")

Select a suiteCommand name Parameters Description Return value Example

SelectSuite() string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

bool isSelected(see page 61)

This methodselects ordeselects aspecified suite.

When thisparameter is setto true, you canselect a suite.

When thisparameter is setto false, you candeselect a suite.

String that givesthe status ofthe operationafter it has beenperformed

The returnvalue is "" (anempty String) onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

Select Suite (Default):

returnval=mClient.Select-Suitet(clientID, "Device","Trans-mitter", true)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

70 TekExpress SATA Compliance Printable Online Help

Page 79: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Select a test

Select a testCommand name Parameters Description Return value Example

SelectTest() string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

bool isSelected(see page 61)

This methodselects ordeselects aspecified test.

If this Settingparameter isset to true, youcan select ameasurement.

If this Settingparameter isset to false, youcan deselect ameasurement.

String thatdisplays thestatus of theoperation afterit has beenperformed

The returnvalue is "" (anempty String) onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL

returnval as string

Select test example (seepage 71)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

Select test example

To select measurement test TSG13-Gen3 Transmitter Jitter:

mClient.SelectTest(clientId, "Device", "Transmitter", "TSG13-Gen3 Transmitter Jitter", true)

TekExpress SATA Compliance Printable Online Help 71

Page 80: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Select a channel

Select a channel

Command name Parameters Description Return value Example

SetGeneralParame-ter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This method setsthe parametersthat are notspecific to anyone test.

NOTE. Usingthis command wecan select a lane,channel, or sourcetype.

String that givesthe status ofthe operationafter it has beenperformed

The returnvalue is "" (anempty String) onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

SetAnalyzeParame-ter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This method setsthe configurationparameters in theAnalyze panel ofthe ConfigurationPanel dialog boxfor a specified suiteor measurement.

The returnvalue is "" (anempty String) onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

SetAcquireParame-ter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This method setsthe configurationparameters in theAcquire panel ofthe ConfigurationPanel dialog boxfor a specified suiteor measurement.

The returnvalue is "" (anempty String) onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnVal = remoteObject.Se-tAcquireParameter(id, device,suite, test, parameterString)

if ((OP_STATUS)

returnVal != OP_STA-TUS.SUCCESS) returnCommandFailed(returnVal)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

72 TekExpress SATA Compliance Printable Online Help

Page 81: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Configure the selected measurement

Configure the selected measurementCommand name Parameters Description Return value Example

SetAnalyzeParame-ter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This methodsets the Analyzeparameters(Configurationparameters) for aspecified test.

The returnvalue is "" (anempty String) onsuccess.

m_Client = new Client()//m_Client is a reference tothe Client class in the Client DLL.

returnval as string

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

TekExpress SATA Compliance Printable Online Help 73

Page 82: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Run with set configurations or stop the run operation

Run with set configurations or stop the run operationCommand name Parameters Description Return value Example

Run() string clientID(see page 63)

Runs the selectedtests Note (seepage 61)

After the serveris set up andconfigured, runit remotely usingthis function.

String that givesthe status ofthe operationafter it has beenperformed.

The return valueis "Run started..."on success.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.Run(clien-tID)

Stop() string clientID(see page 63)

Stops the currentlyrunning tests Note(see page 62)

String that givesthe status ofthe operationafter it has beenperformed

The return valueis "Stopped..." onsuccess.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.Stop(clien-tID)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

74 TekExpress SATA Compliance Printable Online Help

Page 83: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Handle error codes

Handle error codes

The return value of the remote automations at the server-end is OP_STATUS, which changes to a stringvalue depending on its code, and returned to the client. The values of OP_STATUS are as follows:

Code Value Description

-1 FAIL The operation failed

1 SUCCESS The operation succeeded

2 NOT FOUND Server not found

3 LOCKED The server is locked by another client, so the operation cannot be performed

4 UNLOCK The server is not locked; lock the server before performing the operation

0 NULL Nothing

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

TekExpress SATA Compliance Printable Online Help 75

Page 84: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Get or set the timeout value

Get or set the timeout valueCommand name Parameters Description Return value Example

GetTimeOut() string clientID(see page 63)

Returns the currenttimeout period setby the client

String that givesthe status ofthe operationafter it has beenperformed

The defaultreturn value is1800000.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.GetTime-Out()

SetTimeOut() string clientID(see page 63)

string time (seepage 62)

Sets a timeoutperiod specifiedby the client.After this timeoutperiod expires, theserver is unlockedautomatically.

String that givesthe status ofthe operationafter it has beenperformed

On success thereturn value is“TimeOut PeriodChanged”.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.SetTime-Out(clientID, desiredTimeOut)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

76 TekExpress SATA Compliance Printable Online Help

Page 85: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Wait for the test to complete

Wait for the test to complete

The commands in this group execute while tests are running. The GetCurrentStateInfo() andSendResponse() commands are executed when the application is running and in the wait state.

Command name Parameters Description Return value Example

ApplicationStatus() string clientID(see page 63)

This method gets thestatus of the serverapplication.

The states are Ready,Running, Paused,Wait, or Error. (seepage 58)

String valuethat givesthe status ofthe serverapplication

m_Client = new Client()//m_Client is a reference tothe Client class in the ClientDLL.

returnval as string

returnval=m_Client.Applica-tionStatus(clientID)

QueryStatus() string clientID(see page 63)

out string[]status (seepage 61)

An interface forthe user to transferAnalyze panel statusmessages from theserver to the client

String that givesthe status ofthe operationafter it has beenperformed

On success thereturn value is“Transferred...”.

m_Client = new Client()//m_Client is a reference tothe Client class in the ClientDLL.

returnval as string

Query status example (seepage 79)

TekExpress SATA Compliance Printable Online Help 77

Page 86: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Wait for the test to complete

Command name Parameters Description Return value Example

GetCurrentState-Info()

NOTE. Thiscommand isused when theapplication isrunning and is inthe wait or errorstate.

string clientID(see page 63)

out string Wait-ingMsbBx-Caption (seepage 62)

out string Wait-ingMsbBxMes-sage (seepage 63)

out string[]WaitingMsb-BxButtontexts(see page 63)

This method gets theadditional informationof the states when theapplication is in Wait orError state.

Except client ID, allthe others are Outparameters.

This commanddoes not returnany value.

This functionpopulates theOut parametersthat are passedwhen invokingthis function.

m_Client = new Client()//m_Client is a reference tothe Client class in the ClientDLL

mClient.GetCurrentState-Info(clientID, WaitingMsbBx-Caption, WaitingMsbBxMes-sage, WaitingMsbBxButton-texts)

SendResponse()

NOTE. Thiscommand isused when theapplication isrunning and is inthe wait or errorstate.

string clientID(see page 63)

out string Wait-ingMsbBx-Caption (seepage 62)

out string Wait-ingMsbBxMes-sage (seepage 63)

string Wait-ingMsbBxRe-sponse (seepage 63)

After receiving theadditional informationusing the methodGetCurrentStateInfo(),the client can decidewhich response tosend and then sendthe response to theapplication using thisfunction. The responseshould be one ofthe strings that wasreceived earlier asa string array in theGetCurrentStateInfofunction. The _captionand _message shouldmatch the informationreceived earlier in theGetCurrentStateInfofunction.

This commanddoes not returnany value.

m_Client = new Client()//m_Client is a reference tothe Client class in the ClientDLL

mClient.SendResponse(cli-entID, WaitingMsbBxCaption,WaitingMsbBxMessage,WaitingMsbBxResponse)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

78 TekExpress SATA Compliance Printable Online Help

Page 87: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface After the test is complete

Query status example

returnVal=m_Client.QueryStatus(clientID, out statusMessages)

if ((OP_STATUS)returnVal == OP_STATUS.SUCCESS)

return “Status updated...”

else

return CommandFailed(returnVal)

After the test is completeCommand name Parameters Description Return value Example

GetPassFailSta-tus()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

This method getsthe pass or failstatus of themeasurement aftertest completion.

NOTE. Executethis commandafter completingthe measurement.

String that givesthe status ofthe operationafter it has beenperformed

Returns the passor fail status in theform of a string

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.GetPass-FailStatus(clientID,device,suite,"TSG13-Gen3Transmitter Test")

GetResultsValue() string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

This method getsthe result values ofthe measurementafter the run.

String that givesthe status ofthe operationafter it has beenperformed

Returns the resultvalue in the formof a string

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as srting

returnval=m_Client.Ge-tResultsValue(clien-tID,"Device","Transmit-ter",”TSG13-Gen3 TransmitterTest",“True”)

returnval=m_Client.Ge-tResultsValue(clien-tID,"Device","Transmit-ter",”TSG13-Gen3 Trans-mitterTest",“False”)

TekExpress SATA Compliance Printable Online Help 79

Page 88: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface After the test is complete

Command name Parameters Description Return value Example

GetResultsValue-ForSubMeasure-ments()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

string parame-terString (seepage 60)

int rowNr (seepage 60)

This method getsthe result valuesfor individual sub-measurementsafter the run.

String that givesthe status ofthe operationafter it has beenperformed

Returns the resultvalue in the formof a string

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

Get results for asubmeasurement example(see page 82)

GetReportParame-ter()

string clientID(see page 63)

string device(see page 60)

string suite (seepage 60)

string test (seepage 60)

This methodgets the generalreport details suchas oscilloscopemodel,TekExpressversion, and SATAversion.

The returnvalue is theoscilloscopemodel,TekExpressversion, andSATA version.

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

Oscilloscope Model

returnval=m_Client.GetRe-portParameter(clientID,"ScopeModel")

TekExpress Version

returnval=m_Client.GetReport-Parameter(clientID,"TekExpressVersion")

SATA Version

returnval=m_Client.GetReport-Parameter(clientID,"ApplicationVersion")

80 TekExpress SATA Compliance Printable Online Help

Page 89: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface After the test is complete

Command name Parameters Description Return value Example

TransferReport() string clientID(see page 63)

string filePath(see page 62)

This methodtransfers the reportgenerated after therun.

The reportcontains thesummary of therun.

The client mustprovide thelocation wherethe report is tobe saved at theclient-end.

String that givesthe status ofthe operationafter it has beenperformed

Transfers all theresult values inthe form of astring

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.TransferRe-port(clientID,"C:\Report”)

TransferImages() string clientID(see page 63)

string filePath(see page 62)

This methodtransfers all theimages (screenshots) from thespecified clientand folder forthe current run(for a suite ormeasurement).

NOTE. Everytime you clickStart, a folder iscreated in the X:drive. Transfer thewaveforms beforeclicking Start.

String that givesthe status ofthe operationafter it has beenperformed

Transfers all theimages in theform of a string

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.TransferIm-ages(clientID, "C:\Waveforms”)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

string parameterString

Name Type Direction Description

parameterString string IN Specifies the oscilloscope model,TekExpress version, and SATAversion

xxx

TekExpress SATA Compliance Printable Online Help 81

Page 90: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface After the test is complete

Get results for a submeasurement example

This example returns the specified submeasurement results for test TSG13-Gen3 Transmitter Test.

returnval=m_Client.GetResultsValueForSubMeasurements(clientID,"Device","Transmitter","TSG13-Gen3 Transmitter Test ","Value",0)

returnval=m_Client.GetResultsValueForSubMeasurements(clientID,"Device","Transmitter","TSG13-Gen3 Transmitter Test ","Value",1)

82 TekExpress SATA Compliance Printable Online Help

Page 91: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Save, recall, or query a saved session

Save, recall, or query a saved sessionCommand name Parameters Description Return value Example

CheckSession-Saved()

string clientID(see page 63)

out bool saved(see page 59)

This methodchecks whetherthe current sessionis saved.

Return value iseither True orFalse

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.Check-SessionSaved(m_clientID, outsavedStatus)

RecallSession() string clientID(see page 63)

string name(see page 61)

Recalls a savedsession. Theclient providesthe session name.

String that givesthe status ofthe operationafter it has beenperformed

The return valueis “SessionRecalled...”

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.RecallSes-sion(clientID, savedSession-Name)

SaveSession() string clientID(see page 63)

string name(see page 61)

Saves the currentsession. Theclient providesthe session name.

String that givesthe status ofthe operationafter it has beenperformed

The return valueis "Session Sav-ed..."/"Failed..."

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.SaveSes-sion(clientID, desiredSession-Name)

SaveSessionAs() string clientID(see page 63)

string name(see page 61)

Saves the currentsession under adifferent nameevery time thismethod is called.The client providesthe session name.

String that givesthe status ofthe operationafter it has beenperformed

The return valueis "SessionSaved..."

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.SaveSes-sionAs(clientID, desiredSes-sionName)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

TekExpress SATA Compliance Printable Online Help 83

Page 92: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

TekExpress programmatic interface Unlock the server

Unlock the serverCommand name Parameters Description Return value Example

UnlockSession() string clientID(see page 63)

This methodunlocks the serverfrom the client.The ID of the clientto be unlockedmust be provided.Note (see page 62)

String that givesthe status ofthe operationafter it has beenperformed

The return valueis "SessionUn-Locked..."

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.Unlock-Server(clientID)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

Disconnect from the serverCommand name Parameters Description Return value Example

Disconnect() string clientID(see page 63)

This methoddisconnects theclient from theserver.Note (see page 59)

Integer value thatgives the statusof the operationafter it has beenperformed

1 for Success

–1 for Failure

m_Client = new Client()//m_Client is a reference to theClient class in the Client DLL.

returnval as string

returnval=m_Client.Discon-nect(m_clientID)

xxx

NOTE. The Fail condition for PI commands occurs in any of the following cases:

The server is LOCKED and the message displayed is "Server is locked by another client".

The session is UNLOCKED and the message displayed is "Lock Session to execute the command".

The server is NOTFOUND and the message displayed is "Server not found...Disconnect!".

When none of these fail conditions occur, then the message displayed is "Failed...".

84 TekExpress SATA Compliance Printable Online Help

Page 93: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests SATA test definitions

SATA test definitions

The SATA tests listed in this section are available with the application. Some tests my require specificoptions be installed.

TSG01 - Differential Output Voltage - Option 1

This test is to verify that the Differential Output Voltage of the PUT's transmitter is within the conformancelimits. LBP pattern at specified speed is used for the conformance test.

The differential voltage [(Tx+) – (Tx-)] measured at the Transmitter shall comply with the respectiveelectrical specifications. This is measured at mated Serial ATA connector on transmit side includingany pre-emphasis.

TSG01 - Differential Output Voltage - Option 2

This test is to verify that the Differential Output Voltage of the PUT's transmitter is within the conformancelimits. LFTP pattern at specified speed is used for the conformance test.

The differential voltage [(Tx+) – (Tx-)] measured at the Transmitter shall comply with the respectiveelectrical specifications. This is measured at mated Serial ATA connector on transmit side includingany pre-emphasis.

TSG02 - Rise/Fall time

This test is to verify that the Rise/Fall time of the PUT's transmitter is within the conformance limits.

Rise time is the time taken by the DUT output to reach 20% to 80% of the high voltage during transitionand vice versa. Transition happens whenever a bit change happens i.e. from 0 to 1 or from 1 to 0.

This is a DPOJET based measurement. DPOJET is set in such a way that rise time/fall time is calculated asthe time to rise from 20% to 80% of the waveform and vice versa. A LFTP signal is used to make sure thatthe reference levels can be calculated without errors. This will lead to a correct estimation of rise time.

Fall time is the time taken by the DUT output to reach 80% to 20% of the high voltage during transitionand vice versa. Transition happens whenever a bit change happens i.e. from 0 to 1 or from 1 to 0.

This is a DPOJET based measurement. DPOJET is set in such a way that rise time/fall time is calculated asthe time to rise from 20% to 80% of the waveform and vice versa. A LFTP signal is used to make sure thatthe reference levels can be calculated without errors. This will lead to a correct estimation of rise time.

TekExpress SATA Compliance Printable Online Help 85

Page 94: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests TSG03 - Differential Skew

TSG03 - Differential Skew

This test is to verify that the Differential Skew of the PUT's transmitter is within the conformance limits.HFTP and MFTP patterns at specified speeds are used for the conformance test.

Tx Differential Skew is the time difference between the single-ended mid-point of the Tx+ signalrising/falling edge, and the single-ended mid-point of the Tx- signal falling/rising edge. It is an importantparameter to control as excessive skew may result in increased high frequency jitter and common modenoise levels seen at the far end of the interconnect. Excessive Tx Differential Skew also increaseselectromagnetic interference (EMI) emissions.

86 TekExpress SATA Compliance Printable Online Help

Page 95: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests TSG04 - AC Common Mode Voltage

TSG04 - AC Common Mode Voltage

This test is to verify that the AC Common Mode Voltage of the PUT's transmitter is within the conformancelimits. HFTP patterns at Gen 3 speed is used for the conformance test.

A common-mode signal is one that appears in phase and with equal amplitudes on both lines of a two-wirecable with respect to the local common or ground in phase and with equal amplitudes.

This parameter is a measure of common mode noise other than the common mode (CM) spikes duringtransitions due to Tx+/Tx- mismatch and skews that are limited by the rise/fall mismatch and otherrequirements. Measurement of this parameter is achieved by transmitting through a mated connectorinto a lab-load (see following Figure).

The transmitter shall use an MFTP during a data transfer only, not involving OOB transmissions. Themeasurement shall be done with a HBWS having a measurement bandwidth limited on the low end at 200MHz and on the high end at bitrate/2 (fundamental), using first order filtering.

Separate channels shall be used for Tx+ and Tx-, with the common mode being ( Tx+ + Tx- ) / 2. The rawcommon mode is filtered to remove the noise contribution from the edge mismatches. The peak-to-peakvoltage of the filter output is the AC Common Mode Voltage, and shall remain below the specified limit.

TekExpress SATA Compliance Printable Online Help 87

Page 96: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests TSG05 - Rise/Fall Imbalance

TSG05 - Rise/Fall Imbalance

This test is to verify that the Rise/Fall Imbalance of the PUT's transmitter is within the conformance limits.

This parameter is a measure of the match in the simultaneous single-ended rise/fall or fall/rise times of theTransmitter. The test setup shown in the following figure shall be used for this measurement.

This parameter shall be measured and met with both the HFTP and MFTP patterns. In order to determinethe imbalance, the single ended 20% to 80% rise and fall times of both Tx+ and Tx- shall be determinedfor a given pattern. Two imbalance values for that pattern are then determined by the two equations:

Where,

And,

Where,

Both values for each pattern shall follow the limit as per specification.

88 TekExpress SATA Compliance Printable Online Help

Page 97: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests TSG06 - Amplitude Imbalance

TSG06 - Amplitude Imbalance

This test is to verify that the Amplitude Imbalance of the PUT's transmitter is within the conformancelimits.

This parameter is a measure of the match in the single-ended amplitudes of the Tx+ and Tx- signals. Thetest setup shown following figure shall be used for this measurement.

This parameter shall be measured and met with both the HFTP and MFTP patterns. Clock-like patternsare used here to enable the use of standard mode-based amplitude measurements for the sole purpose ofdetermining imbalance. Due to characteristics of the MFTP, it is required that the measurement pointsbe taken between 0.45 UI to 0.55 UI of the second bit within the pattern. All amplitude values for thismeasurement shall be the statistical mode measured at 0.5 UI, nominal, over a minimum of 10 000 UI.

In order to determine the amplitude imbalance, single ended mode high and mode low based amplitudes ofboth Tx+ and Tx- over 10 cycles to 20 cycles of the clock-like pattern being used shall be determined. Theamplitude imbalance value for that pattern is then determined by the equation:

Where,

Both values for each pattern shall follow the limit as per specification.

TekExpress SATA Compliance Printable Online Help 89

Page 98: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests TSG09 - Gen1 TJ at connector Clock to Data fBAUD-500

TSG09 - Gen1 TJ at connector Clock to Data fBAUD-500

This test is to verify that the TJ at Connector of the PUT's transmitter is within the conformance limits.

Total Jitter is a measure of how erroneous the signal is. Lower jitter means less error and higher jittermeans more errors. This is a DPOJET based measurement. This is a DPOJET based measurement.Measurements are made on the differential signal.

This test will be performed while the DUT is transmitting HFTP and LBP patterns. The specificationrequires that the measurement include the effects of the JTF (Jitter Transfer Function), which is aStandard-defined weighting function that is intended to separate the low-frequency timing variations dueto SSC from the actual jitter. The TJ measurement requires that the Jitter Measurement Device (JMD) beconfigured to use the proper JTF characteristics required by the Standard.

TSG10 - Gen1 DJ at connector Clock to Data fBAUD-500

This test is to verify that the DJ at Connector of the PUT's transmitter is within the conformance limits.

Deterministic Jitter is a measure of how the deterministic event like periodic jitter affects the signal. Lowerjitter means less errors and higher jitter means more errors.

This test will be performed while the DUT is transmitting HFTP and LBP patterns. The specificationrequires that the measurement include the effects of the JTF (Jitter Transfer Function), which is aStandard-defined weighting function that is intended to separate the low-frequency timing variations dueto SSC from the actual jitter. The RJ measurement requires that the Jitter Measurement Device (JMD) beconfigured to use the proper JTF characteristics required by the Standard.

TSG11 - Gen2 TJ at connector Clock to Data fBAUD-500

This test is to verify that the TJ at Connector of the PUT's transmitter is within the conformance limits.HFTP and LBP patterns at Gen2 Speed are used for conformance test.

Total Jitter is a measure of how erroneous the signal is. Lower jitter means less error and higher jittermeans more errors. This is a DPOJET based measurement. This is a DPOJET based measurement.Measurements are made on the differential signal.

This test will be performed while the DUT is transmitting HFTP and LBP patterns. The specificationrequires that the measurement include the effects of the JTF (Jitter Transfer Function), which is aStandard-defined weighting function that is intended to separate the low-frequency timing variations dueto SSC from the actual jitter. The TJ measurement requires that the Jitter Measurement Device (JMD) beconfigured to use the proper JTF characteristics required by the Standard.

90 TekExpress SATA Compliance Printable Online Help

Page 99: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests TSG12 - Gen2 DJ at connector Clock to Data fBAUD-500

TSG12 - Gen2 DJ at connector Clock to Data fBAUD-500

This test is to verify that the DJ at Connector of the PUT's transmitter is within the conformance limits.HFTP and LBP patterns at Gen2 Speed are used for conformance test.

Deterministic Jitter is a measure of how the deterministic event like periodic jitter affects the signal. Lowerjitter means less errors and higher jitter means more errors.

This test will be performed while the DUT is transmitting HFTP and LBP patterns. The specificationrequires that the measurement include the effects of the JTF (Jitter Transfer Function), which is aStandard-defined weighting function that is intended to separate the low-frequency timing variations dueto SSC from the actual jitter. The RJ measurement requires that the Jitter Measurement Device (JMD) beconfigured to use the proper JTF characteristics required by the Standard.

TSG13 - Gen3 Transmit Jitter

This test is to verify the maximum amount of jitter that a transmitter may generate and still be SATAcompliant. LBP and MFTP patterns at Gen 3 speed are used for the conformance test.

Transmit Jitter is a measure of how erroneous the signal is. Lower jitter means less error and higher jittermeans more errors. This is a DPOJET based measurement. This is a DPOJET based measurement.Measurements are made on the differential signal. This test will be performed while the DUT istransmitting LBP pattern. The specification requires that the measurement include the effects of the JTF(Jitter Transfer Function), which is a Standard-defined weighting function that is intended to separatethe low-frequency timing variations due to SSC from the actual jitter. The RJ measurement requiresthat the Jitter Measurement Device (JMD) be configured to use the proper JTF characteristics requiredby the Standard.

The Transmit Jitter values TJ(10-12) and TJ(10-6) specified in specification refer to the output signal fromthe DUT at the mated connector into a lab-load. The signals are not specified while attached to a systemcable or backplane. All the interconnect characteristics of the transmitter, package, printed circuit boardtraces, and mated connector pair are included in the measured transmitter jitter. Since the SATA adapteris also included as part of the measurement, good matching and low loss in the adapter are desirable tominimize its contributions to the measured transmitter jitter.

TekExpress SATA Compliance Printable Online Help 91

Page 100: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests TSG14 - Gen3 TX Maximum Differential Voltage Amplitude

TSG14 - Gen3 TX Maximum Differential Voltage Amplitude

The differential voltage measured at the Transmitter shall comply with the respective electricalspecifications of section 7.2. MFTP pattern at Gen 3 speed is used for the conformance test.

The differential voltage [(Tx+) – (Tx-)] measured at the Transmitter shall comply with the respectiveelectrical specifications.

This is measured at mated Serial ATA connector on transmit side including any pre-emphasis. For Gen3iand Gen3u the maximum differential output voltage is likewise measured at the TX compliance point.

TSG15 - Gen3 TX Minimum Differential Voltage Amplitude

This test is to verify that the AC Common Mode Voltage of the PUT's transmitter is within the conformancelimits for SATA Gen3i. LBP pattern at Gen 3 speed is used for the conformance test.

The differential voltage [(Tx+) – (Tx-)] measured at the Transmitter shall comply with the respectiveelectrical specifications.

This is measured at mated Serial ATA connector on transmit side including any pre-emphasis. Theminimum differential output voltage is measured after the Gen3i CIC. The minimum voltage for Gen3uis not measured after the Gen3i CIC.

Eye Diagram

This test is an informative test.

An eye diagram is a common indicator of the quality of signals in high-speed digital transmissions. Anoscilloscope generates an eye diagram by overlaying sweeps of different segments of a long data streamdriven by a master clock. The triggering edge may be positive or negative, but the displayed pulse thatappears after a delay period may go either way; there is no way of knowing beforehand the value of anarbitrary bit. Therefore, when many such transitions have been overlaid, positive and negative pulsesare superimposed on each other. Overlaying many bits produces an eye diagram, so called because theresulting image looks like the opening of an eye.

In an ideal world, eye diagrams would look like rectangular boxes. In reality, communications areimperfect, so the transitions do not line perfectly on top of each other, and an eye-shaped pattern results.On an oscilloscope, the shape of an eye diagram will depend upon various types of triggering signals,such as clock triggers, divided clock triggers, and pattern triggers. Differences in timing and amplitudefrom bit to bit cause the eye opening to shrink.

92 TekExpress SATA Compliance Printable Online Help

Page 101: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests PHY01 - Unit Interval

PHY01 - Unit Interval

This measurement is for measuring the unit interval or bit rate of a signal. It verifies that the unit interval iswithin the conformation limits.

PHY02 - Long term Frequency Stability

This measurement finds the rate of change of frequency with time.

For the purpose of this test, first the time points will be found where the differential signal crosses zerovolts (such as, zero crossings). A diff (difference) operation will be performed on this array of time valuesto produce an array of Unit Interval (UI) widths. The high frequency changes in UI are errors and will beremoved by filtering the data using a low-pass filter, which will reveal the underlying lower-frequencystability of the link rate.

The inverse of the UI values will be taken to produce an array of instantaneous frequency values. The lowpass filter will then be applied to the inverse of the UI values. The resulting waveform that is producedat the output of the test filter will then be converted to ppm. This result will represent the instantaneousbitrate of the DUT. All of the values must be between specified limit as per specification.

PHY03 - Spread Spectrum Modulation Frequency

This measurement is for finding the Spread spectrum modulation frequency. If the waveform has SSC thismeasurement will return SSC frequency.

In this test, the SSC modulation frequency of the DUT’s transmitted output signaling will be measuredwhile the DUT is transmitting SSC. A sample of the DUT’s data signaling will be captured using areal-time DSO, and will be post processed to recover the transmitter’s SSC modulation profile. Thefrequency of the modulation will be observed by measuring the average period over a minimum of 10 SSCcycles, and the inverse of this result will be computed to produce the modulation frequency result.

TekExpress SATA Compliance Printable Online Help 93

Page 102: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests PHY04 - Spread-Spectrum Modulation Deviation

PHY04 - Spread-Spectrum Modulation Deviation

This measurement verifies that the max SSC Spread is less that 0.23% or less that 2300 ppm. Thedeviation of the modulation will be determined by measuring maximum and minimum profile peak valuesper period, over at least 10 complete SSC cycles. From these values, the average maximum and averageminimum peak values will be computed, and the results compared against the requirements listed abovefor the appropriate SSC modulation types.

dF/dt Measurement

This is an informative test.

This measurement finds the rate of change of frequency with time. It calculates the deviation of UI valuefrom the Nominal/standard UI. It calculates the first order derivative of unit interval with respect totime and reports the maximum.

In this test, the slope of the SSC profile will be computed using post-processing techniques. The profileused will be the profile that was measured in the Modulation deviation and Balance test. An additionalprocessing step will be performed on the profile, where a “sliding window” will be moved across theprofile values to compute the slope. This window will have a width of 0.27 μs, and the slope value foreach horizontal point will be calculated.

The DFDT result must be no greater than conformant limit as per specification.

94 TekExpress SATA Compliance Printable Online Help

Page 103: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB01 - Signal Detection Threshold

OOB01 - Signal Detection Threshold

Determines whether a product properly ignores OOB signals that are too small, and that a product properlydetect OOB signals that are properly sized.

TekExpress SATA Compliance Printable Online Help 95

Page 104: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB01 - Signal Detection Threshold

96 TekExpress SATA Compliance Printable Online Help

Page 105: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB02 - UI during OOB Signaling

OOB02 - UI during OOB Signaling

Determines that a product transmits OOB bursts using the proper UI (unit interval / bit time) of: 646.7 ps< t < 686.67 ps.

TekExpress SATA Compliance Printable Online Help 97

Page 106: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB03 - COMINIT/RESET and COMWAKE Transmit Burst Length

OOB03 - COMINIT/RESET and COMWAKE Transmit Burst Length

Determines that a burst within any OOB signal is the proper length (160 OOBI): 103.5 ns < t < 110.9 ps.

98 TekExpress SATA Compliance Printable Online Help

Page 107: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB04 - COMINIT/RESET Transmit Gap Length

OOB04 - COMINIT/RESET Transmit Gap Length

Determines that a Gap within a COMINIT/RESET signal is the proper length (480 OOBI) : 310.4 ns < t< 329.6 ps.

TekExpress SATA Compliance Printable Online Help 99

Page 108: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB05 - COMWAKE Transmit Gap Length

OOB05 - COMWAKE Transmit Gap Length

Determines that a Gap within a COWAKE signal is the proper length (160 OOBI): 102.4 ns < t < 109.9 ps.

100 TekExpress SATA Compliance Printable Online Help

Page 109: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB06 - COMWAKE Gap Detection Windows

OOB06 - COMWAKE Gap Detection Windows

Determine that a Product responds to COMWAKE signals with a Gap Length of 155 OOBI and 165 OOBI.

TekExpress SATA Compliance Printable Online Help 101

Page 110: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB07 - COMINIT Gap Detection Windows

Determine that a Product ignores COMWAKE signals with a Gap Length of 45 OOBI and 266 OOBI.

OOB07 - COMINIT Gap Detection Windows

Determine that a Product responds to COMINIT/RESET signals with a Gap Length of 459 OOBI and501 OOBI.

102 TekExpress SATA Compliance Printable Online Help

Page 111: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB07 - COMINIT Gap Detection Windows

Determine that a Product ignores COMINIT/RESET signals with a Gap Length of 259 OOBI and 791OOBI.

TekExpress SATA Compliance Printable Online Help 103

Page 112: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests OOB07 - COMINIT Gap Detection Windows

104 TekExpress SATA Compliance Printable Online Help

Page 113: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests RSG01 - GEN1 (1.5 Gb/S) Receiver Jitter Test

RSG01 - GEN1 (1.5 Gb/S) Receiver Jitter Test

This test requirement is applicable to all products. (Gen1i/m/u-Gen3i/u)

The above test is based around testing the receiver channel using a directly synthesized framed compositepattern with a precise level of digital impairment using an Arbitrary Waveform Generator. SATA RSG 01test is a Pass/Fail test on whether the receiver can tolerate a laboratory-grade impaired framed compositetest signal.

This library includes all stressed patterns including RJ, Dj including CIC/ISI and with sine Pj sourcefrequencies of 5 MHz, 10 MHz, 33 MHz and 62 MHz.

A jitter tolerance curve is then created that shows where the device fails. This information is useful invalidating the design of the receiver.

RSG02 - GEN2 (3 Gb/S) Receiver Jitter Test

This test requirement is applicable to all PUTs claiming ability to run Gen2i/u and Gen3i/u rates.

The above test is based around testing the receiver channel using a directly synthesized framed compositepattern with a precise level of digital impairment using an Arbitrary Waveform Generator.

SATA RSG 02 test is a Pass/Fail test on whether the receiver can tolerate a laboratory-grade impairedframed composite test signal.

This library includes all stressed patterns including RJ, Dj including CIC/ISI and with sine Pj sourcefrequencies of 5 MHz, 10 MHz, 33 MHz and 62 MHz.

RSG03 - GEN3 (6 Gb/S) Receiver Jitter Test

This test requirement is applicable to all PUTs claiming ability to run Gen3i/u rates.

The above test is based around testing the receiver channel using a directly synthesized framed compositepattern with a precise level of digital impairment using an Arbitrary Waveform Generator.

SATA RSG 03 test is a Pass/Fail test on whether the receiver can tolerate a laboratory-grade impairedframed composite test signal.

This library includes all stressed patterns including RJ, Dj including CIC/ISI and with sine Pj sourcefrequencies of 5 MHz, 10 MHz, 33 MHz and 62 MHz.

TekExpress SATA Compliance Printable Online Help 105

Page 114: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests RSG05 - Asynchronous Receiver Stress Test

RSG05 - Asynchronous Receiver Stress Test

This test requirement is applicable to all PUTs.

The above test is based around testing the receiver channel using a directly synthesized framed compositepattern with a precise level of digital impairment using an Arbitrary Waveform Generator.

SATA RSG 01 test is a Pass/Fail test on whether the receiver can tolerate a laboratory-grade impairedframed composite test signal.

This library includes all stressed patterns including RJ, Dj including CIC/ISI and with sine Pj sourcefrequencies of: 62 MHz.

RSG06 - Asynchronous Receiver Stress Test with SSC

This test requirement is applicable to all PUTs.

The above test is based around testing the receiver channel using a directly synthesized framed compositepattern with a precise level of digital impairment using an Arbitrary Waveform Generator.

SATA RSG 01 test is a Pass/Fail test on whether the receiver can tolerate a laboratory-grade impairedframed composite test signal.

This library includes all stressed patterns including RJ, Dj including CIC/ISI and with sine Pj sourcefrequencies of 62 MHz.

RMT01 - Gen1 (1.5 Gb/S) Receiver Margin Test

This test requirement is applicable to Gen1 products. (Gen1i/m/u)

When the RMT01 test is selected, jitter is synthesized at different frequencies and amplitudes increasinglyuntil errors are detected on the frame error analyzer.

We have different ways to provide jitter:

1. Linear pass to Fail

2. High Performance Scan Pass to Fail

3. Select Scan Parameter Preset

The above test is based around testing the receiver channel using a directly synthesized framed compositepattern with a precise level of digital impairment using an Arbitrary Waveform Generator.

A jitter tolerance curve is then created that shows where the device fails. This information is useful invalidating the design of the receiver.

106 TekExpress SATA Compliance Printable Online Help

Page 115: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests RMT02 - Gen2 (3.0 Gb/S) Receiver Margin Test

RMT02 - Gen2 (3.0 Gb/S) Receiver Margin Test

This test requirement is applicable to Gen2 products. (Gen2i/m/u)

When the RMT02 test is selected, jitter is synthesized at different frequencies and amplitudes increasinglyuntil errors are detected on the frame error analyzer.

We have different ways to provide jitter:

1. Linear pass to Fail

2. High Performance Scan Pass to Fail

3. Select Scan Parameter Preset

The above test is based around testing the receiver channel using a directly synthesized framed compositepattern with a precise level of digital impairment using an Arbitrary Waveform Generator.

A jitter tolerance curve is then created that shows where the device fails. This information is useful invalidating the design of the receiver.

RMT03 - Gen3 (6.0 Gb/S) Receiver Margin Test

This test requirement is applicable to Gen3 products. (Gen3i/ u) When the RMT03 test is selected,jitter is synthesized at different frequencies and amplitudes increasingly until errors are detected on theframe error analyzer.

We have different ways to provide jitter:

1. Linear pass to Fail

2. High Performance Scan Pass to Fail

3. Select Scan Parameter Preset

The above test is based around testing the receiver channel using a directly synthesized framed compositepattern with a precise level of digital impairment using an Arbitrary Waveform Generator.

A jitter tolerance curve is then created that shows where the device fails. This information is useful invalidating the design of the receiver.

TekExpress SATA Compliance Printable Online Help 107

Page 116: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

SATA tests RMT03 - Gen3 (6.0 Gb/S) Receiver Margin Test

108 TekExpress SATA Compliance Printable Online Help

Page 117: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Index

Index

AAbout TekExpress, 5Acquire Status, 25Acquisitions tab, 21Activating the license, 3Analysis Status, 25Application commands, 58Application controls, 10Application directories, 7Application features, 5Application version

information, 4Application window, 10ApplicationStatus(), 77Auto Scroll, 26

CChannel selection commands, 72CheckSessionSaved(), 83Clear test log, 26Client programmatic interface

flowchart, 53Client proxy object, 51Code example, remote access, 56Command buttons, 10Commands

Connect(), 63GetAcquireParameter(), 69GetAnalyzeParameter(), 69GetDutId(), 66GetGeneralParameter(), 69LockSession(), 64SelectTest(), 71SetAcquireParameter(), 67SetAnalyzeParameter(), 67SetDutId(), 66SetGeneralParameter(), 67

Commands list, 58Common measurements, 23Configuration Parameter

query, 69Configure Selected Measurement

commands, 73

Configuring tests, 23Connect(), 63Connected instruments, 39Connection requirements, 36Conventions, 1

DDefault directory, 7Deskew utility, 14Directories, 7Disable Popups command, 65Disconnect from Server

command, 84Disconnect(), 84DUT connection setup, 36DUT ID commands, 66DUT settings, 17DUT tab, 17DUT term, 1

EEmail notifications, 13Email settings, 12Equipment setup, 36Exit the application, 9

FFeatures, 5File name extensions, 8

GGear selection, 17GetAcquireParameter(), 69GetAnalyzeParameter(), 69GetCurrentStateInfo(), 78GetDutId(), 66GetGeneralParameter(), 69GetPassFailStatus(), 79GetReportParameter(), 80GetResultsValue(), 79GetResultsValueForSubMeasure-

ments(), 80

GetTimeOut(), 76Global settings, 23

IInstalling the software, 3Instrument reset before each test

run, 14Instruments

selecting, 23viewing connected, 39

Instruments detected, 23Interface error codes, 75IP address connection

commands, 63

LLane source, 21License activation, 3License information, 4LockSession(), 64Log files, 26Log View, 25

MMeasurement selection

commands, 71Menus, 10

Options, 11preferences, 27

Message History, 26Mode, 23Move icon

moving the application, 10My TekExpress folder, 28

locating, 43

OOptions menu, 11Options Menu

Instrument ControlSettings, 12

Oscilloscopes supported, 5

TekExpress SATA Compliance Printable Online Help 109

Page 118: TekExpress SATA Compliance Automated Solution Printable ...€¦ · Microsoft .NET 4.0 Framework Microsoft Internet Explorer 6.0 SP1 or later Adobe Reader 7.0 or equivalent software

Index

PPanels

overview, 16plots, 28reports, 29results, 26Results, 27Setup overview, 16Status, 25

Pass/Fail summary, 31Position the application, 10Pre-run checklist, 45Pre-Run checklist, 43Program example, 56Programmatic interface, 49

QQueryStatus(), 77

RRecallSession(), 83Related documentation, 1Remote proxy object, 51Report contents, 32

selecting, 30Report file type, 30Report names, 30Report options, 30Reports

view, 31Reports panel, 29Reset before test run, 14Restore oscilloscope settings, 14Results panel, 27Run commands, 74Run the application, 9Run(), 74

SSATA test definitions, 85Save oscilloscope settings before

running tests, 14SaveSession(), 83SaveSessionAs(), 83Saving test setups, 47

Schematic button, 18Select lane source, 21Select Required button, 18Selecting DUT parameters, 17SelectSuite(), 70SelectTest(), 71SendResponse(), 78Server control, 50Server locking commands, 64Session files, 28Session folders, 28Session Status commands, 83Set Configuration Parameters

commands, 67SetAcquireParameter(), 67SetAnalyzeParameter(), 73SetDutId(), 66SetGeneralParameter(), 72SetTimeOut(), 76Setting up tests, 41Setup tabs

Acquisitions, 21DUT, 17Test Selection, 18

SetVerboseMode(), 65Show application version, 4Signal Path Compensation

(SPC), 43Signal source validation

overview, 21setting, 21

Software, 6Software installation

SATA software, 3Specification version, 17Status Panel, 25Stop commands, 74Stop(), 74Suite selection commands, 70Supported equipment, 5System requirements, 6

TTab

Acquisitions, 21DUT, 17

Test Selection, 18Technical support, 2TekExpress client, 49TekExpress client require-

ments, 50TekExpress server, 49Test configuration, 23Test groups, 35Test notifications, 22Test parameters, 23Test reports, 31Test results, 27Test results commands, 79Test run instrument reset, 14Test selection controls, 18Test Selection tab, 18Test setup files, 28Test setup overview, 35Test setup steps, 41Test setups, 47

creating based on existing, 48recalling, 48saving, 47

Test Status, 25Test Status commands, 77Tests, 23

running, 43selecting, 18setting up, 35

Timeout Value commands, 76TransferImages(), 81TransferReport(), 81

UUnlock Server command, 84UnlockSession(), 84Untitled Session folder, 43User comments