teide termo plus+ - welcome to valvulas arco · 2019-10-21 · use the manual closing cap provided...

9
The thermostatic valves and heads from TEIDE TERMO PLUS series can be used in individual or collective heating networks. These valves allow the regulation and control of the water flow in radiators from bi-tube heating networks, keeping the room temperature at the desired value. Nominal pressure: 10 bar Water Temperature range: Up to 110ºC Room setting range: 6ºC at 28ºC teide termo plus+ SCOPE COMPONENTS THERMOSTATIC VALVES 1 2 3 4 9 8 7 6 5 SERVICE CONDITIONS Item Component Material Treatment 1 Nut European brass CW617N Chrome 2 Coupling European brass CW614N Chrome 3 O-ring NBR 4 Closure cap ABS White color 5 Open - Close European brass CW614N 6 Body European brass CW617N Chrome 7 Sleeve NBR 8 Ring European brass CW614N 9 Nut European brass CW617N Chrome TECHNICAL SHEET 07/2017 | IP20060 PAG. 1/9 HEATING SERIES QUALITY BY TRADITION

Upload: others

Post on 19-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: teide termo plus+ - Welcome to Valvulas Arco · 2019-10-21 · Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap

The thermostatic valves and heads from TEIDE TERMO PLUS series can be used in individual or collective heating networks. These valves allow the regulation and control of the water flow in radiators from bi-tube heating networks, keeping the room temperature at the desired value.

Nominal pressure: 10 barWater Temperature range: Up to 110ºCRoom setting range: 6ºC at 28ºC

teide termo plus+

SCOPE

COMPONENTS

THERMOSTATIC VALVES

1 2 3 4

9 8 7 6 5

SERVICE CONDITIONS

Item Component Material Treatment

1 Nut European brass CW617N Chrome

2 Coupling European brass CW614N Chrome

3 O-ring NBR

4 Closure cap ABS White color

5 Open - Close European brass CW614N

6 Body European brass CW617N Chrome

7 Sleeve NBR

8 Ring European brass CW614N

9 Nut European brass CW617N Chrome

TECHNICAL SHEET 07/2017 | IP20060

PAG. 1/9

HEATINGSERIES QUALITY BY TRADITION

Page 2: teide termo plus+ - Welcome to Valvulas Arco · 2019-10-21 · Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap

COMPONENTS

PAG. 2/9

1 2 3 5

91011 8 7 6

4

Item Component Material Treatment

1 Nut European Brass CW617N Chrome

2 Washer European Brass CW614N Chrome

3 Coupling European Brass CW614N Chrome

4 O-ring NBR

5 O-ring EPDM

6 Handle ABS

7 Stem European Brass CW614N

8 Body European Brass CW617N Chrome

9 Bicone NBR

10 Ring Brass

11 Nut European Brass CW617N Chrome

O-ring NBR

O-ring EPDM

Shaped gasket Metal reinforcement

MAIN CONSTRUCTIVE FEATURES

Internal leaktightness

The closure mechanism has been designed with a special shaped rubber assuring a prefect closure. A plus in order to increase the reliability agaists over pressures in the network, it has been added in the rear part of the shaped rubber a metallic disc in the rear part.

External leaktightness

A double EPDM seal placed on the stem ensures the external leak tightness. The system with double seal provides extra security against leaks, aging, wearing, ... In the other hand an extra NBR o-ring has been placed in the coupling junction increasing the reliability of the metallic closure.

QUALITY BY TRADITION

Page 3: teide termo plus+ - Welcome to Valvulas Arco · 2019-10-21 · Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap

DIMENSIONS

Size A B C D E

1/2 24.5 1/2 50 1/2 M28

1/2 24.5 1/2 50 1/2 M30

3/8 24.5 3/8 50 3/8 M28

THERMOSTATIC VALVE Screwed angle

Size A B C D E

1/2 24.5 M24x1.5 50 1/2 M28

THERMOSTATIC VALVE Compression angle

PAG. 3/9

Washer

MAIN CONSTRUCTIVE FEATURES

Anti Drip O-ring

An EPDM O-ring placed in the coupling and positioned by a washer prevents a possible drip between the radiator and the valve coupling.

QUALITY BY TRADITION

O-ring

Page 4: teide termo plus+ - Welcome to Valvulas Arco · 2019-10-21 · Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap

DIMENSIONS

PAG. 4/9

Size A B C D

1/2 71 1/2 1/2 M28

1/2 71 1/2 1/2 M30

THERMOSTATIC VALVE Screwed Straight

Size A B C D

1/2 47 1/2 1/2 M28

1/2 47 1/2 1/2 M30

THERMOSTATIC VALVE Screwed Inverted

Size A B C D E

1/2 24.5 M24x1.5 53 1/2 M28

THERMOSTATIC VALVE Angle Compression Anti Drip O-ring

D

C

A

A

C

B

B

ED

QUALITY BY TRADITION

Page 5: teide termo plus+ - Welcome to Valvulas Arco · 2019-10-21 · Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap

PAG. 5/9

Sensor type LiquidMaximum working pressure 10 barWorking temperature range Hot water up to 120ºCRoom temperature setting range 6ºC a 28ºCMaximum differential pressure 1,2 barRecommended differential pressure 0,6 bar

THERMOSTATIC HEAD V3

SERVICE CONDITIONS

COMPONENTS

1 2 3 4 5

Item Component Material Treatment

1 Nut European brass CW617N Nickel

2 Temperature sensor ABS Grey color

3 Main body ABS White color

4 Liquid sensor

5 Distinctive ABS White color

Thermostatic Head

QUALITY BY TRADITION

Page 6: teide termo plus+ - Welcome to Valvulas Arco · 2019-10-21 · Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap

Sensor type LiquidMaximum working pressure 10 barWorking temperature range Hot water up to 120ºCRoom temperature setting range 6ºC a 28ºCMaximum differential pressure 1,2 barRecommended differential pressure 0,6 bar

THERMOSTATIC HEAD V4

SERVICE CONDITIONS

PAG. 6/9

The thermostatic head includes a temperature selector; it allows the temperature setting in the room where it has been installed, according to the following table:

Thermostatic head must not be placed behind curtains or other similar obstructions, and should not be exposed to direct sunlight or other heat or cold sources. All these factors can modify the proper working of the thermostatic head, changing the relationship shown in the above table position – temperature, that means that one position will not correspond to a temperature.

DIMENSIONS

MAIN CONSTUCTIVE FEATURES

0 * 1 2 3 4 5

Close 6ºC 12ºC 16ºC 20ºC 24ºC 28ºC

Size A B C

M28 81-88 52 M28

M30 81-88 52 M30

A

BC

QUALITY BY TRADITION

Page 7: teide termo plus+ - Welcome to Valvulas Arco · 2019-10-21 · Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap

Selector and temperature scale

The thermostatic head includes a temperature selector; it allows the temperature setting in the room where it has been installed, according to the following table:

Thermostatic head must not be placed behind curtains or other similar obstructions, and should not be exposed to direct sunlight or other heat or cold sources. All these factors can modify the proper working of the thermostatic head, changing the relationship shown in the above table position – temperature, that means that one position will not correspond to a temperature.

DIMENSIONS

MAIN CONSTUCTIVE FEATURES

0 * 1 2 3 4 5

Close 6ºC 12ºC 16ºC 20ºC 24ºC 28ºC

Size A B C

M28 78-83 45 M28

M30 78-83 45 M30

COMPONENTS

Item Component Material Treatment

1 Nut European brass CW617N Nickel

2 Temperature sensor ABS Grey color

3 Main body ABS White color

4 Retention ring

5 Liquid sensor ABS White color

1 2 3 4 5

PAG. 7/9

QUALITY BY TRADITION

Page 8: teide termo plus+ - Welcome to Valvulas Arco · 2019-10-21 · Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap

LOCATION OF THE VALVE

Thermostatic radiator valve shall be fitted at the inlet of the radiator. The valve shall be positioned so that the thermostatic head (sensor component) remains in horizontal position and can detect the temperature of the air in the room.

Thermostatic head must not be placed behind curtains or other similar obstructions, and should not be exposed to direct sunlight or other heat sources.

CONTROL ADJUSTMENT SCALE

Thermostatic head is provided with calibration marks, which correspond to following temperatures:

INSTALLATION

Before installing the valve ensure that the heating system is shut off and free of dirt in accordance with good plumbing practices.Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap and screw down sufficiently to close the valve. Do not over-tighten.2. Connect the valve to radiator and tube, fill the system, bleed radiator and check for leaks.3. Remove the manual closing cap and store it in a safe place for future use.4. Turn thermostatic head to fully open (position 5) and assemble it on the valve’s body, ensuring that the indicator line can be seen. Tighten knurled securing ring by hand. Do not over-tighten or use grips, etc...

PAG. 8/9

0 * 1 2 3 4 5

Close 6ºC 12ºC 16ºC 20ºC 24ºC 28ºC

HYDRAULIC FEATURES

INSTALATION AND ASSEMBLY

THERMOSTÁTIC VALVE SQUARE

10

100

1.000

10.000

10 1.000100 10.000

Loss

of p

ress

ure

Flow (l/h)

Flow vs. Loss pressure

THERMOSTÁTIC VALVE STRAIGHT

10

100

1.000

10.000

10 1.000100 10.000

Loss

of p

ress

ure

Flow (l/h)

Flow vs. Loss pressure

QUALITY BY TRADITION

Page 9: teide termo plus+ - Welcome to Valvulas Arco · 2019-10-21 · Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap

SETTING THE TEMPERATURE

Select the desired room temperature from the table above and turn the knob to align the appropriate number with the arrow on the fixed part of the head. To change the room temperature, readjust the setting. TEMPERATURE BLOCKING(Just available for V3 model)

In order to avoid the manipulation of the selected temperatura, the valve has as blocking ring that allows you to block the head in the desired position.

In order to block the head temperature, select the desired position and pull the ring upwards. After this maneuver the thermostatic head will remain blocked until the ring is repositioned to its initial position. FROST PROTECTION

When heating is not required, and there is a danger of freezing, the valves may be turned to the frost protection setting * which will allow the valves to open if the temperature falls below approx 6ºC. The boiler must remain operational, controlled by a frost protection thermostat. RADIATOR REMOVAL

To remove a radiator it is necessary to use the manual shut-off cap supplied with the valve. Remove the thermostatic head and substitute the manual shut-off cap. Close the valve manually and proceed in the normal way.

SUMMER OPERATION

If the heating system is to be turned off for a lengthy period (eg. during the summer months), it is recommended that all valves are set to the fully open (position ‘5’).

INSTALATION AND ASSEMBLY

QUALITY BY TRADITION

Av. del Cid, 1646134 | Foios | Valencia | Spain

Engineering departament:Tel: +34 963 171 [email protected]

valvulasarco.com

Every product has an impact on the environment during all stages of its life-cycle, including final disposal. All components of these valves can be recycled, deposit the valve in a green or recycled point when no longer useful.Válvulas ARCO, SL reserves the right to change our products and specifications at any time and without prior notice.

QUALITY BY TRADITION

PAG. 9/9