Page 1: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

technical

E45

Page 2: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45 Panels The new E45 panel system is the latest member to the Schiavello range of dividing panel systems. Featuring a new and evolved design that allows for improved manufacturing and faster lead times. E45 with its integrated cable reticulation presents quality engineering, elegant simplicity and flexibility to your workplace.

Page 3: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45 _01

Indexpanels 02-05junctions connectors 06-08 junction post 9panel combinations 10-11worksurfaces 12cable reticulation 13accessories 14-15core storage range 16product specifications 17

Page 4: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

Panelsplain base panels I base ducted base panels

Key Features•Highflexibilitywithfastassembly,reconfigurationandrelocationrequiringa single allen key.•Panelsare45mmthickwith(loadbearing)toptransomrail.•Minimalcomponentryrequiredforpaneljunctionsavailablein90º,120º and linear.•StackerpanelsareNOTavailablewiththeE45basepanels.•Extensiveselectionofpaneltypescoloursandfinishes.•Allcomponentsarereusable.

•Flushmounteddoublesidedcableducts.SuitableforAustralianand International wiring systems.•Choiceofstandardpanelconstruction,optionalpinableoracousticsound absorbing panel cores.•Seamlesscompatibilitywithcomprehensiverangesofdesking,storage, tables and accessory options.

PLAIN BASE PANELS

BASE DUCTED BASE PANELS

code E45.S1

code E45.SBP1

code E45.S2

code E45.SGBP

code E45.S1-TT

code E45.SBP1-TT

code E45.S2-TT

code E45.SBP2-TT

code E45.S1-FWT

code E45.SBP1-FWT

STANDARD SIZES - BASE PANELS

panel widths (mm)

450 600 750 800 900 1200 1500 1800 2100 2400

900 • • • • • • • • • •

1050 • • • • • • • • • •

1200 • • • • • • • • • •

1350 • • • • • •

1500 • • • • • •

1800 • • • • • •

2100 • • • • • •

2400 • • • • • •

nb. Special sizes available on request.

pane

l hei

ghts

(mm

)

code E45.G1-1

code E45.GBP1-1

code E45.PG1-1

code E45.PGBP-1

code E45.SG1-1

code E45.SGBP1-1

code E45.SG1-2code E45.PG1-2

code E45.PG1-3

code E45.SGBP1-2code E45.PGBP-2

code E45.G1-2

code E45.GBP1-2

code E45.SG1-3

code E45.SGBP1-3code E45.PGBP-3

code E45.G1-3

code E45.GBP1-3

a _Solid panel.

b _Two piece solid panel with mid transom.

c _Solid panel with removable feature divider rail.

d _Two piece solid panel with mid transom and

removable feature divider rail.

e _Solid panel with function wall top transom.

f _Two piece solid panel with,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

g _Solid panel with,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

h _Centrefullglazedpanel.

_Offsetfullglazedpanel.

_Double full flush glazed panel.

i _Solid panel with base duct.

j _Two piece solid panel with mid transom and base duct.

k _Solid panel with removable feature divider rail and base duct.

l _Two piece solid panel with mid transom and

removable feature divider rail and base duct.

m _Solid panel with function wall top transom and base duct.

n _Two piece solid panel, with base duct and,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

o _Solid panel with base duct and,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

p _Centrefullglazedpanelwithbaseduct.

_Offsetfullglazedpanelwithbaseduct.

_Double full flush glazed panel with base duct.

a

e

b

f

c

g

d

h

i

m

j

n

k

o

l

p

Page 5: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45_03

Panelsmid ducted base panels I plain void panels

Void panels•Voidpanelshavearaisedbottomrailcreatinga300mm/400mmvoidbetween the underside of the panel and the floor.

MID DUCTED BASE PANELS

PLAIN VOID PANELS

code E45.SP1

code E45.V1

code E45.SP2

code E45.V2

code E45.SP1-TT

code E45.V1-TT

code E45.SP2-TT

code E45.V2-TT

code E45.SP1-FWT

code E45.V1-FWT

STANDARD SIZES - BASE PANELS

panel widths (mm)

450 600 750 800 900 1200 1500 1800 2100 2400

900 • • • • • • • • • •

1050 • • • • • • • • • •

1200 • • • • • • • • • •

1350 • • • • • •

1500 • • • • • •

1800 • • • • • •

2100 • • • • • •

2400 • • • • • •

nb. Special sizes available on request.

pane

l hei

ghts

(mm

)

code E45.GP1-1

code E45.VG1-1

code E45.PGP1-1

code E45.VPG1

code E45.SGP1-1

code E45.VSG1-1

code E45.SGP1-2code E45.PGP1-2

code E45.VSG1-2code E45.VPG2

code E45.GP1-2

code E45.VG1-2

code E45.SGP1-3code E45.PGP1-3

code E45.VSG1-3code E45.VPG3

code E45.GP1-3

code E45.VG1-3

a _Two piece solid panel with mid duct.

b _Three piece solid panel with mid transom and mid duct.

c _Two piece solid panel with removable feature divider rail and mid duct.

d _Three piece solid panel with mid transom,

removable feature divider rail and mid duct.

e _Two piece solid panel with function wall top transom and mid duct.

f _Two piece solid panel with mid duct and,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

g _Solid panel with mid duct and,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

h _Centrefullglazedpanelwithmidduct.

_Offsetfullglazedpanelwithmidduct.

_Double full flush glazed panel with mid duct.

i _Solid panel.

j _Two piece solid panel with mid transom.

k _Solid panel with removable feature divider rail.

l _Two piece solid panel with mid transom and

removable feature divider rail.

m _Solid panel with function wall top transom.

n _Two piece solid panel with

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

o _Solid panel with

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

p _Centrefullglazedpanel.

_Offsetfullglazedpanel.

_Double full flush glazed panel.

a

e

b

f

c

g

d

h

i

m

j

n

k

o

l

p

Page 6: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

Panelsbase ducted void panels I mid ducted void panels I special void panels

BASE DUCTED VOID PANELS

MID DUCTED VOID PANELS

SPECIAL VOID PANELS

STANDARD SIZES - VOID PANELS

panel widths (mm)

450 600 750 800 900 1200 1500 1800 2100 2400

900 • • • • • • • • • •

1050 • • • • • • • • • •

1200 • • • • • • • • • •

1350 • • • • • •

1500 • • • • • •

1800 • • • • • •

2100 • • • • • •

2400 • • • • • •

nb. Special sizes available on request.

pane

l hei

ghts

(mm

)

a _Solid panel with base duct.

b _Two piece solid panel with mid transom and base duct.

c _Panelwithremovablefeaturedividerrailandbaseduct.

d _Two piece solid panel with mid transom,

removable feature divider rail and base duct.

e _Solid panel with function wall top transom and base duct.

f _Two piece solid panel with base duct and,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

g _Solid panel with base duct and,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

h _Centrefullglazedpanelwithbaseduct.

_Offsetfullglazedpanelwithbaseduct.

_Double full flush glazed panel with base duct.

i _Two piece solid panel with mid duct.

j _Three piece solid panel with mid transom and mid duct.

k _Two piece solid panel with

removable feature divider rail and mid duct.

l _Three piece solid panel with mid transom,

removable feature divider rail and mid duct.

m _Two piece solid panel with function wall top transom and mid duct.

n _Two piece solid panel with mid duct and,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

o _Solid panel with mid duct and,

_Centrepartialglazedpanel.

_Offsetpartialflushglazedpanel.

_Double partial flush glazed panel.

p _Centrefullglazedpanelwithmidduct.

_Offsetfullglazedpanelwithmidduct.

_Double full flush glazed panel with mid duct.

q _Solid panel with base duct.

r _Solid panel with removable feature divider rail and base duct.

s _Solid panel with function wall top transom and base duct.

t _Centrepartialglazedpanelwithbaseduct.

_Offsetpartialflushglazedpanelwithbaseduct.

_Double partial flush glazed panel with base duct.

code E45.RP1 code E45.RP1-FWTcode E45.RP1-TT code E45.RGP1-1

code E45.RGP1-2

code E45.RGP1-3

code E45.VBP1

code E45.VP1

code E45.VBP2

code E45.VP2

code E45.VBP1-TT

code E45.VP1-TT

code E45.VBP2-TT

code E45.VP2-TT

code E45.VBP1-FWT

code E45.VP1-FWT

code E45.VGB1-1

code E45.VGP1-1

code E45.VPGBP1-1

code E45.VPGP1-1

code E45.VSGBP1-1

code E45.VSGP1-1

code E45.VSGBP1-2code E45.VPGBP1-2

code E45.VSGP1-2code E45.VPGP1-2

code E45.VGB1-2

code E45.VGP1-2

code E45.VSGBP1-3code E45.VPGBP1-3

code E45.VSGP1-3code E45.VPGP1-3

code E45.VGB1-3

code E45.VGP1-3

a

e

b

f

c

g

d

h

i

m

q

j

n

r

k

o

s

l

p

t

Page 7: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45 _05

Panelstop ducted panels I wall starter bracket I suspended panel I removable feature divider I finishes

code WS.1B-E45 code S45-CLM-L.H.

code S45-CLM-R.H.

code SA-RFD code 6mm SA-G6

code 10mm SA-G10

code SA-RFDC code SA-RFD

WALL STARTER BRACKETAttachesE45paneltowall1 - bracket required

SUSPENDED PANEL ATTACHING BRACKETS

REMOVABLE FEATURE DIVIDER INFILLS AND COVERRemovable feature divider infills are available in a wide variety of materials including laminated glass and perspex, in either 6mmor10mmthicknesses.Heightandwidthscanbevariedtosuitparticularrequirementsandmustbespecified.Coversarenot supplied with the panel and must be specified seperately.Note:Removablefeaturedividersrequireglazingrubber, ordered seperately, and to be fitted on site. - Fit rubber over glass and then slide into top rail.

Note:Applicabletoboththeremovablefeaturedividerrail and the function wall top transom rail.

FINISHES

Fabric PerforatedmetalCRperforation

Infill Infill coverGlazing rubber

Assemblysignholder

PerforatedmetalMWperforation

Pinablefabricscreen

PowdercoatMDF Laminate Veneer Echo panel

Panelfacescanbespecifiedinavarietyoffinishesasillustrated.

TOP DUCTED PANELS a_Solid panel with top duct,

b_Solid void panel with top duct.

c_Solid suspended panel with top duct.

Note:suspendedpanelsdonotincludeor make height allowance for glides.

code E45.SP3 code E45.VP3 code E45.SP3-S

a b c

Page 8: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

Junction Connectorsfoot casting I 180° straight junction I90°twowayopenjunctionI transition height panels I straight junction

JUNCTION CONNECTORS Junction connectors for transition height junctions are specified individually, not per set. Each of the examples shown below indicate the connector product codes and the quantity required of each to achieve the junction.

180° STRAIGHT JUNCTION

STRAIGHT JUNCTION

TRANSITION HEIGHT PANELS

COMMON HEIGHT PANELS

TRANSITION HEIGHT PANELS

code E45.J180.T

connectors required

code E45.J90.2W.O

connectors required

1-type WS.1B.E45 1-typeE45MFC

2-typeP12462 2-typeE45SEFC

code E45.J180.1W.S

2-typeP124611-typeE45MFC

code E45JFC

Junction foot casting Stop end foot casting Modulefootcasting

Used to connect panel to post.

Usedin2-waystraightjunctions between panels.

Used at the end of a panel run and each panel in open junctions.

code E45SEFC code E45MFC

90° TWO WAY OPEN JUNCTION

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm

200 mm

200 mm

200 mm

FOOT CASTINGSFootCastings,whichincorporateadjustableglides,areusedforscreenlevellingand straight panel to panel or panel to post connections at the base of the screen.

Page 9: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45 _07

Junction Connectors90°twowayopenjunctionI90°threewayopenjunctionI common height panels I lettric tech column

Each common height junction has an individual product code no. as shown.Connectorsarespecified as one set for each junction.

By specifying the code no’s and quantities of the junctions required, the appropriate quantity and type of connectors will be supplied.

200 mm 200 mm

200 mm 200 mm

COMMON HEIGHT PANELS90° TWO WAY OPEN JUNCTION

COMMON HEIGHT PANELS90° THREE WAY OPEN JUNCTION

LETTRIC TECH COLUMN

200 mm 200 mm

200 mm 200 mm

4-typeP124623-typeE45SEFC

a_1-type lettric technology column -mainextrusion-P12854 -spreaderextrusion-017225 -removablecover-017224b_1-type top cap typea_A4010006 typeb_A4010008c_3-typeWS1B-E45connectord_3-typeE45JFCfootcasting

code E45.J90.3W.O

code E45.LTC

2-typeP124622-typeE45SEFC

code E45.J90.2W.O

a cb_type b

b_type a

d

Note:70mmoffset

Overallpanelwidthisequalto the nominated worktop widthMINUS70mm.

70 mm

Page 10: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

Junction Connectors120°threewayumbilicaljunctionI120°threewayjunctionI90°fourwayjunctionI 90°fourwayumbilicaljunctionI common height panels

Each common height junction has an individual product code no. as shown.Connectorsarespecified as one set for each junction.

By specifying the code no’s and quantities of the junctions required, the appropriate quantity and type of connectors will be supplied.

120° THREE WAY UMBILICAL JUNCTION COMMON HEIGHT PANELS

COMMON HEIGHT PANELS

COMMON HEIGHT PANELS

COMMON HEIGHT PANELS

code E45.J120.3W

6-typeP124633-typeE45SEFC

6-typeP12465 3-typeE45SEFC

8-typeP12462 4-typeE45SEFC

8-typeP12466 4-typeE45SEFC

code E45.J120.3W.C

code E45.J90.4W.C

code E45.J90.4W.O

Note:20mmoffset

20mm

28mm

Overallpanelwidthisequalto the nominated worktop widthMINUS20mm.

Overallpanelwidthisequalto the nominated worktop widthMINUS28mm.

Note:28mmoffset

120° THREE WAY JUNCTION

90° FOUR WAY JUNCTION

90° FOUR WAY UMBILICAL JUNCTION

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

Page 11: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45_09

Junction Postend post support I90°twowaycornerpostI 180° straight corner post I90°threewaycornerpostI 90°fourwaycornerpost

END SUPPORT POST

180° STRAIGHT CORNER POST

90° THREE WAY CORNER POST

CornerjunctionpostforE45panels.Formstwoway,threewayandfour way junctions with either common height or transition height panels.

Cablescanberoutedtomidductedpanelsfromfloorsandskirtings.Specify cabling requirements and panel heights.

code E45.JP.1W

a_1-typeP12338junctionpostb_1-typeE45POSTCAPc_1-type WS1B-E45 connectord_1-typeE45JFCfootcasting

code E45.JP.2W

a_1-type P12338junctionpostb_1-typeE45POSTCAPc_2-typeWS1B-E45connectord_2-typeE45JFCfootcasting

code E45.JP.2S

a_1-typeP12338junctionpostb_1-typeE45POSTCAPc_2-typeWS1B-E45connectord_2-typeE45JFCfootcasting

code E45.JP.3W

a_1-typeP12338junctionpostb_1-typeE45POSTCAPc_3-typeWS1B-E45connectord_3-typeE45JFCfootcasting

a

a

a

a

a

c

c

c

c

c

b

b

b

b

b

d

d

d

d

d

code E45.JP.4W

a_1-typeP12338junction postb_1-typeE45POSTCAPc_4-type WS1B-E45 connectord_4-typeE45JFCfootcasting

90° FOUR WAY CORNER POST

90° TWO WAY CORNER POST

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200 mm 200 mm

200

mm

200

mm

200

mm

200

mm

Page 12: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45 panel combinationssystem30I centric I marina

E45 PANELS WITH CENTRIC WORKSTATIONS AND VERTICAL DUCTE45 base ducted fabric spine panels, with integrated cable reticulation and faceaccessedpoweranddataoutlets.E45voidreturnpanelwithCentricheight adjustable workstations and a mobile pedestal to each position.

E45 PANELS WITH SYSTEM 30 SUSPENDED PANELS AND CENTRIC LINEAR DESKINGE45 mid-ducted, floor standing fabric panels configured as spine wall with integrated cable reticulation and face accessed power and data outlets. Function wall top rail with removable glass feature divider. CentricLineardeskswithlinearconnectedreturns,System30suspendedpanelsattachedwithclamp brackets as privacy screens and a mobile pedestal to each position.

E45 PANELS WITH SYSTEM 30 SUSPENDED PANELS AND MARINA WORKSTATIONSE45 mid-ducted floor standing fabric panels configured as spine wall, with integrated cable reticulation andfaceaccessedpoweranddataoutlets.Marina90degreeheightadjustableworkstationswith System30suspendedpanelattachedasaprivacyscreen.Mobilepedestalstoeachposition.

Page 13: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45 _11

E45 PANELS WITH MARINA DESKINGE45mid-ducted,floorstanding,partialglazed/fabricpanelswithintegratedcablereticulationandfaceaccessedpoweranddataoutlets.Returnwallfeaturessolidfabricpanelswithcliponbookshelves.MarinadeskinginstalledinU-shapedconfigurationwithfrontmodestypaneland2mobilepedestals.

E45 PANELS WITH 90 DEGREE CENTRIC WORKSTATIONSE45 base-ducted fabric panels with integrated cable reticulation and face mounted power and data outlets. E45voiddividerpanelconnectedtomainspinewitha3waypost.Centric90degreeheightadjustableworkstations, with a slimline shelf and mobile pedestal to each position.

E45 PANELS WITH 120 DEGREE CENTRIC WORKSTATIONSE45 base-ducted fabric void panel with integrated cable reticulation and face accessed power and data outlets. Centric120degreeheightadjustableworkstationsinstalledwithamobilepedestaltoeachposition.

Page 14: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

Worksurfacestypical workstation clusters for E45 I worksurface support brackets I worksurface support legs

R

R

R

R L

L

L

R

600 mm

800 mm

R

WorksurfacesWorksurfacescanbespecifiedeither25mmor33mmthick.Availablefinishesincludeselectedlaminates,timberveneersandpowdercoatedMDFinarange of colours.

There is a wide selection of shapes and sizes to ensure the right solution for task specific requirements. Edge finishes and shapes also offer many choices with custom shapes available on request.

TYPICAL WORKSTATION CLUSTERS FOR E45Clusterexamplesusingvariousshapedworksurfaces.

WORKSURFACE SUPPORT BRACKETS

WORKSURFACE SUPPORT LEGSFixed height

WORKSURFACE SUPPORT LEGSHeightadjustable

code S45.D400LH-45-C

length 350 mm

Curveddesksupportbrackets.Lefthand.

code S45.D400RH-45-C

length 350 mm

Curveddesksupportbrackets.Right hand.

code DJ-50

length 50 mm x 50 mm

Underdesk joining plates.

code S45.FTS-LH

Front top support brackets.Lefthand.

code S45.FTS-RH

Front top support brackets.Right hand.

a_code S45.D400RH-C

b_code S45.D600RH-C

length a_358mm/b_495mm

Curveddesksupportbrackets.Right hand.

a_code S45.D400LH-C

b_code S45.D600LH-C

length a_358mm/b_495mm

Curveddesksupportbrackets.Lefthand.

a_code S45.D400D-C

b_code S45.D600D-C

length a_358mm/b_495mm

Curveddoubledesksupport brackets.

code DJ-300/400/500/600mm

depth 150 mm

width 300/400/500/600mm

Underdesk joining plate.

code S45/PNL-LCK-GUIDE

Panellockingguide.(Unhanded)(Holdspanelsagainstadjustableheightworksurface).

a a

a

b b

b

code QLIF-NB-10°

dia. 28mmdia.QED

height Leg695mmplus work surface.

code U10 leg

dia. 70 mm dia. leg

height Leg687mmplus work surface.

code QED3-STRT

height Heightadjustable leg610mmto 735mmplus work surface.

code QED3-10°

height Heightadjustable leg610mmto 735mmplus work surface.

code Marinaleg

height Heightadjustable leg625mmto 705 mm plus work surface.

code QLIF-NB-STRT

dia. 28mmdia.QED

height Leg695mmplus worksurface.

Page 15: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45_13

Cable Reticulationpower blades I power poles umbilical I umbilicals I inline vertical duct

Cable routingE45 offers a number of cable routing options. They can be combined to satisfy specific requirements while always providing easy access and efficient cable management throughout entire layouts.

Cablescanberoutedtopanelsfromceiling,wallsorfloorsbyutilisingumbilicals,power blades or power poles.

POWER POLESFull height corner posts, or power poles, are able to route cables from ceilings, floorsandskirtingsintopanelducts.Pleasespecifycablingrequirements,adjoining panels and ceiling heights.

POWER BLADESAccessfromceilingorfloor.Lengthstoorder.Rangeofcolours.

INLINE VERTICAL DUCT Direct access via removable duct cover.Poweranddatacablingcanbeaccessedviaceilings,floorsandskirtings.Services outlets visible, mounted to duct face.Pleasespecifycablingrequirements,adjoiningpanelsandceilingheights.

specify cabling requirements and adjoining panel heights

45 mm

200mm

power/dataoutlets

height as required

panels attach with standard wallstarter

REMOVABLE DUCT COVER

UMBILICALSAccessfromceilingorfloor.Lengthstoorder.Rangeofcolours.

300mmor 600mmwide

floor to ceiling

cables exit power blade and enter panel cable duct

power/data outlets

power pole

cable duct

cable duct

umbilical

height as required

height as required

specify cabling requirements and panel heights

Page 16: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

code ADR-P2-D2

ADR-P2R-D2

ADR-P4-D2

ADR-P4R-D2

Dual Power - Double Data - VerticalDual Power - Double Data - RotatedQuad Power - Double Data - VerticalQuad Power - Double Data - Rotated

Dual Power - Double Data - VerticalDual Power - Double Data - RotatedQuad Power - Double Data - VerticalQuad Power - Double Data - Rotated

code LEC-BL

LEC-BL-DBL

LEC-D2

LEC-D2-AF

code LEC-PM2-FM

LEC-PM2R-FM

LEC-PM4-FM

LEC-PM4R-FM

Dual Power Module_Face Mounted VerticalDual Power Module_Face Mounted RotatedQuad Power Module_Face Mounted VerticalQuad Power Module_Face Mounted Rotated

Tile Blank SingleTile Blank DoubleTile_Two DataTile_Two Data_Angled Face

code IDR-P2-D2

IDR-P2R-D2

IDR-P4-D2

IDR-P4R-D2

code LEC-SS

Starter Socket

code LEC-TP

Tee - Plug

code LEC-JB

Junction Box

Power Module Clip

code CLIP 62

code LEC-EX-AS

Installation LeadRight Angle Socket

code LEC-EX

Installation Lead

code SR/2P/4D

SR/3P/4D

SR/4P/4DPower + data service boxInserts into desktops

code IDBO.1

Power + data service rails

code LEC-SS

Starter Socket

code LEC-TP

Tee - Plug

code LEC-JB

Junction Box

Power Module Clip

code CLIP 62

LEC-PM4

code LEC-PM2

Dual Power ModuleQuad Power Module

code LEC-EX-AS

Installation LeadRight Angle Socket

code LEC-EX

Installation Lead

code NGDM/2

NGDM/4

NGDM/6

Data modules

Accessorieslettric I humanscale ergonomic accessories I service access I standard duct outlet positions

LETTRIC SOFTWIRING SYSTEMSchiavello softwiring system delivers power and lighting to workstations. The system is easily connected, disconnected or relocated without the need to isolate power and with minimal inconvenience.Allconnectionswithinsystemsareprotectedbyapositivelockmechanism to prevent accidental power disconnection.

Therearenumerousoutletcombinationsavailableforeachoption.RefertoSchiavelloLettricbrochure SCH/LE01-Aforcompleteproductinformationandtechnicalspecification.

FACE MOUNTED POWER MODULESNote:SeetheLettricBrochureforthe fullrangeofLettricsoftwiringproducts.

POWER + DATA SERVICE RAILS(Mountstorearofdesktop)

DATA MODULES POWER + DATA SERVICE BOX(Insertsintodesktop)suitablewherespanbetween legs does not exceed 1800 mm

HUMANSCALE ERGONOMIC ACCESSORIESUncompromising performance-centric design in its purest form is at the heart of every Humanscalesolution.Eachoftheergonomicproductsisdesignedforuncomplicateduse,maximum comfort, a long serviceable life, and a minimal environmental footprint.

code ELUBW

Task light

code CPU-600W

CPU60089mmto203mmwide and305mmto508mmhigh (Optionalrubberspaceravailable)

code CPU-600lite

CPU600lite60mmto230mmwide and205mmto305mmhigh (Smallerwidthachievedusing rubberspacerprovided)

code M8DW-C

Monitorarmdouble

code M2CW

Monitorarmsinglearm

200 mm 200 mm

200 mm 200 mm

eco45 joins clean.ai

Overall panel width is equal to the nominated worktop width MINUS 20mm

20 mm

Overall panel width is equal to the nominated worktop width MINUS 28mm

28 mm

SERVICE ACCESS OPTIONS FOR DUCTED PANELS STANDARD DUCT OUTLET POSITIONS Standardductfacepunchoutpositionsforpower/dataoutletmodules.Suitallwidths.Note:Datacannotbeplacedbacktoback.

There are numerous outlet combinations available for each option. RefertoSchiavelloLettricforcompleteproductinformationandtechnicalspecifications.

TYPE 1

Direct access.Services outlets visible, mounted to duct face.

Transom rail

Nominateleft hand punch-outs

Nominatecentre punch-outs

Nominateright hand punch-outs

Page 17: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45 _15

Accessoriesfunction walls I accessories

Function wallsMounttotransomrailsofpanelsviaintegralmountingdetail.Additionalbracketsnotrequired.

FUNCTION WALLSSpecify width

code FWT-150

height 150 mm

code FWT-450

height 450 mm

code FWT-300

height 300 mm

BENTO PLASTIC ACCESSORIES

code ULT-STRAY

side_a 245mm

side_b 319mm

side_c 26mm

Stationarytray(A4portrait)

code ULT-STRAY-A4

side_a 313mm

side_b 251mm

side_c 26mm

Stationarytray(A4landscape)

code ULT-SHLF-25

side_a 300mm

side_b 600/750/900/1050/1200mm

side_c 250/300/350/410mm

Shelf

code ULT/SHLF-LINE-0600-DIV

side_a 300mm

side_b 600/750/900/1050/1200mm

Slimline shelf

code ULT-PTRAY/SM

side_a 50 mm

side_b 158 mm

side_c 26mm

Penciltray-small

code ULT-PTRAY/LG

side_a 122 mm

side_b 319mm

side_c 26mm

Penciltray-large

code ULT/SL/SHELF-600

side_a 225mm

side_b 600/750/900/1050/1200mm

Slimline mini shelf

code ULTCDSHELF

side_a 200mm

side_b 150/260/390/520mm

CDholder

code ULT-PHBOOK

side_a 115 mm

side_b 265mm

side_c 272mm

Phonebookholder

code ULT-PHTRAY

side_a 245mm

side_b 325mm

side_c 39mm

Phonetray

code TH/CH

side_a 40 mm

side_b 40mm(overallheight)

Coathook

code TH/NAMEPLATE170

side_a 49mm

side_b 170 mm

Nameplate

a

aa a aa

aa

a aa

a

a a

a

a a

a

aa

b

bb b bb

bb

cc

ccc

cc

b

b b

bb

b

d

bb

b b cc

c

c

c cc

cc

POWDER COATED METAL ACCESSORIES

bb

code ULT/VASE

side_a 67mm

side_b 40 mm

side_c 125mm

side_d 25mm

Vase

code BT/BM3

side_a 150 mm

side_b 73.5mm

side_c 21.5mm

code BT/BM4

side_a 73.5mm

side_b 73.5mm

side_c 21.5mm

code BT/BM

side_a 316mm

side_b 163.4mm

side_c 25mm

code BT/BM2

side_a 150 mm

side_b 150 mm

side_c 21.5mm

code BT/BM5

side_a 73.5mm

side_b 73.5mm

side_c 100 mm

code BT/BM6

side_a 150 mm

side_b 73.5mm

side_c 100 mm

code BT/STRAY

side_a 316mm

side_b 230.4mm

side_c 25mm

Page 18: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

Core Storage Range

Mobile Pedestals - Metal500 mm deep and 450 mm deep models0.95mmzinc-sealsteel,antirustcarcassanddrawers.Powdercoatedfinishavailableinselectedcolours.

Operateonrunnerswithkeylockingsystem.Injectionmouldedpencil drawer where shown. Timber drawer fronts optional.

CORE LOW PEDESTALSLow pedestal - Suitable for height adjustable desksDimensions:525mmhighx450mmwidex500mmdeep 525mmhighx450mmwidex450mmdeep

Tall pedestal - Suitable for fixed height deskDimensions:600mmhighx450mmwidex500mmdeep 600mmhighx450mmwidex450mmdeep

CORE COMBO PEDESTALS

CORE LATERAL FILE UNIT

CORE VERTICAL TAMBOUR DOOR UNIT

a

b b b

b

b

b

b

b b

b

a aa

a

a

a

a

a

a

c c c c

c

c

c

c

c c

code C/CVT2-3-500-600H-SP

side_a 600 mm

side_b 900|1200mm

side_c 500 mm

Corecombopedestalandtambourdoor.Availableasleft-handor right-hand unit.

code C/LF-4

side_a 1236mm

side_b 900 mm

side_c 512mm

4 draw file

code C/CVT-5

side_a 1524mm

side_b 900 mm

side_c 512mm

code C/LF-2

side_a 660 mm

side_b 900mm

side_c 512 mm

2drawfile

code C/CVT-3

side_a 948 mm

side_b 900mm

side_c 512 mm

code C/CMPT-3-500-600H-SP

side_a 600 mm

side_b 900|1200mm

side_c 500 mm

Corecombopedestalandopenshelf. Availableasleft-handorright-hand unit.

code C/LF-3

side_a 948mm

side_b 900 mm

side_c 512mm

3drawfile

code C/CVT-4

side_a 1236 mm

side_b 900 mm

side_c 512mm

code C/MPL-2-500

height 525 mm depth 500mm

C/MPL-2-450

height 525mmdepth 450 mm

code C/MPL-3-500

height 525 mm depth 500 mm

C/MPL-3-450

height 525mmdepth 450 mm

code C/MPT-2D/PD-500

height 600 mm depth 500 mm

C/MPT-2D/PD-450

height 600mmdepth 450 mm

code C/CVT-2

side_a 660 mm

side_b 900mm

side_c 512 mm

code C/CVT-6

side_a 1812 mm

side_b 900mm

side_c 512 mm

code C/MPL-3-500

height 600 mm depth 500 mm

C/MPT-3-450

height 600mmdepth 450 mm

Page 19: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

E45 _17

Product specificationsgeneral I panels I connectors I corner posts I cable reticulation I aluminium finish I warranty

General E45 is a fully refined office panel system manufactured by Schiavello Australia. The System is easily demountable, relocated, extended or reduced in size with all components being reusable.

PanelsE45 panels, with a thickness of 45 mm and individual panel widths of up to 2400mm, are available in either base or void configurations. All E45 panels include a load bearing top transom rail. The solid construction, resulting in a rigid panel, provides the strength to support hampers, shelves and worktops from any of the vertical or horizontal transoms of the panel. The panel’s support a full range of attachable accessory items and options for either integrated or transom mounted whiteboards and function walls.

Note: Stacker panels are not compatible with E45 panels.Panel faces offer a choice of finishes including fabric, perforated metal, powder coat MDF, laminate, timber veneer and fabric covered pin boards as well as single and double glazing.Acoustic panels are also offered that have an acoustic sound absorption rate of no less than 60 NRC.

ConnectorsThe connecting system achieves the following junctions and connection:a) 90°, 120°, 180°b) Two way, three way and four way junctions with open access corners.

Corner PostsE45 corner posts form 90° and 180° degree junctions in two way, three way and four way configurations. Cables can be routed from skirtings, floor access or ceilings for full height power pole applications.

Cable ReticulationPanels offer optional integrated cable ducts with ‘face mounted’ service outlets to one or both sides of the panel. A wide selection of clip-in outlet modules and soft wiring connections are available.The system also includes integrated components that provide efficient means of routing services cabling to the panels from the ceiling, walls or floors, i.e. power blades, umbilicals, inline vertical duct or power poles. The soft wiring electrical system is Schiavello Lettric certified to AS/NZS 3131.

Aluminium FinishAll aluminium is powder coated to Australian Standard AS-NZ3570.

WarrantyThe manufacturer warrants the system for a period of not less than 5 years against faulty materials and workmanship and guarantees the supply of parts and service of all standard components for a period of not less than 10 years from the date of installation.

M A N A G E M E N T S Y S T E M

I S O 14 0 0 1

ENVIRONMENTALC E R T I F I E D C E R T I F I E D

QUALIT YM A N A G E M E N T S Y S T E M

I S O 9 0 0 1

Page 20: technical - · PDF fileE45 with its integrated cable reticulation presents quality engineering, ... , storage, tables and accessory ... - Fit rubber over glass and then slide into

schiavello.com SCH/E45-02-A

SchiavelloGroupPtyLtdreserves the right to change any or all details without priornotice.Alldimensions stated within this document arenominaland/orapproximate only and subject to variation.

Melbourne Head OfficeSchiavello(Vic)PtyLtd1 Sharps RoadTullamarineVICAustralia3043T:61)393308888F:61)393308899

Melbourne ShowroomSchiavello(Vic)PtyLtdMetropol8 Whiteman StreetSouthbankVICAustralia3006T:61)396741500F:61)396741650

AdelaideSchiavello(SA)PtyLtdGroundFloor,101CurrieStreetAdelaideSAAustralia5000T:08)81122300F:08)82311419

BrisbaneSchiavello(Qld)PtyLtd265CoronationDriveMiltonQLDAustralia4064T:07)33683388F:07)33682125

CanberraSchiavello(ACT)PtyLtd2-6CollieStreetFyshwickACTAustralia2609T:02)61240500F:02)62804370

PerthSchiavello(WA)PtyLtd1315HayStreetWestPerthWAAustralia6005T:08)94206588 F:08)93221337

SydneySchiavello(NSW)PtyLtd69CampbellStreetSurryHillsNSWAustralia2010T:02)92113311F:02)92123788

SingaporeSchiavelloSingaporePteLtdNo.1MagazineRoad#01-05CentralMallSingapore059567T:65)65338011F:65)65332811