technical specifications - atacama atacama 5 model h1-w1 ... › user_uploads › files › hi-line_...
TRANSCRIPT
ATACAMA 5
ATACAMA 10
ATACAMA 15
ATACAMA 20
ATACAMA 35
ATACAMA 50
ATACAMA 75
ATACAMA 100
420-366-245-226-106
670-366-245-226-106
920-366-245-226-106
1120-366-245-226-106
992-550-375-273-160
1242-550-375-273-160
1036-755-495-338-220
1386-755-495-338-220
1/4"
1/4"
1/4"
1/4"
1/2"
1/2"
1"
1"
5
10
15
20
35
50
75
100
HF20-2&3
HF20-2&3
HF20-2&3
HF20-2&3
HF72-2&3
HF72-2&3
HF120-2&3
HF120-2&3
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
14
18
24
28
51
60
93
114
MODEL H1-W1-W2-D1-D2
Dimensions mm
Conn Cfm m3/h m3/min l/sIncluded Filters
Max Working Pressure Weight
Corrected Flow Rate
0.14
0.28
0.42
0.57
0.99
1.41
2.12
2.83
2.3
4.7
7.1
9.4
16.5
24
36
47
8.49
17
25.5
34
59.5
84.95
127.4
170
Technical Specifications - Atacama
ATACAMA 10-CT
ATACAMA 15-CT
ATACAMA 20-CT
ATACAMA 35-CT
ATACAMA 50-CT
ATACAMA 75-CT
ATACAMA 100-CT
672-515-355-226-106
922-151-388-226-106
1122-151-388-226-106
995-773-590-273-160
1245-773-590-273-160
1037-1050-780-338-220
1387-1050-780-338-220
1/4"
1/4"
1/4"
1/2"
1/2"
1"
1"
10
15
20
35
50
75
100
HF20-2&3
HF20-2&3
HF20-2&3
HF72-2&3
HF72-2&3
HF120-2&3
HF120-2&3
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
30
38
44
77
92
145
178
MODEL H1-W1-W2-D1-D2
Dimensions mm
Conn Cfm m3/h m3/min l/sIncluded Filters
Max Working Pressure Weight
Corrected Flow Rate
0.28
0.42
0.57
0.99
1.41
2.12
2.83
4.7
7.1
9.4
16.5
24
36
47
17
25.5
34
59.5
84.95
127.4
170
Technical Specifications - Atacama CT
ATACAMA 10-CT(BA)
ATACAMA 15-CT(BA)
ATACAMA 20-CT(BA)
ATACAMA 35-CT(BA)
ATACAMA 50-CT(BA)
ATACAMA 75-CT(BA)
ATACAMA 100-CT(BA)
672-515-355-226-106
922-151-388-226-106
1122-151-388-226-106
995-773-590-273-160
1245-773-590-273-160
1037-1050-780-338-220
1387-1050-780-338-220
HF20-2&3
HF20-2&3
HF20-2&3
HF72-2&3
HF72-2&3
HF120-2&3
HF120-2&3
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
30
38
44
77
92
145
178
MODEL H1-W1-W2-D1-D2
Dimensions mm
1/4"
1/4"
1/4"
1/2"
1/2"
1"
1"
Conn
1
2
3
4
5
6
12
Masks
7
13
18
26
35
54
80
CfmIncluded Filters
Max Working Pressure
WeightCorrected Flow Rate
m3/min
0.2
0.36
0.5
0.73
0.99
1.53
2.26
l/s
3.3
6.1
8.5
12
17
26
38
m3/h
12
22
30
44
59
91
135
Technical Specifications - Atacama-CT (Breathing Air)
High Quality Compressed Air - At Point of Use
MEDICALDENTALPHARMACEUTICALMANUFACTURING
ATACAMAPERFORMANCE
Dimensional Drawing - Atacama
W1
W2
H
D2D1
W1
W2
H
D2D1
Dimensional Drawing - Atacama CT
HDC1 Digital Dewpoint Display
PERFORMANCE
VERSION 2 04/2017All specifications and details are subject to change without prior notice.
Hi-line Industries Ltd.5 Crown Industrial Estate
Oxford Street
Burton-upon-Trent
Staffordshire
DE14 3PG
Tel: 01283 533 377 Fax: 01283 533 367
Email: [email protected]
www.hilineindustries.com
In the Atacama CT all of the above values are greatly over achieved by using a mixed bed in the third tower
consisting of Hopcalite, Activated Carbon and 13 X Molecular Sieve. Providing the operator with high quality breathing air at an affordable price, whilst being compliant
with British & European Legislation.
Oxygen
Carbon Dioxide
Carbon Monoxide
Oil
Water Airline <40Bar
(21 ± 1)%
≤ 500 PPM
≤ 5 PPM
≤ 0.5 mg/m3
Where the apparatus is used
and stored at
a known temperature the
pressure dewpoint shall be at
least 5°C below likely lowest
temperature. Where the
conditions of usage and
storage of any compressed air
supply is not known the
pressure dewpoint shall not
exceed -11°C.
Odour
The gas shall be freefrom unsatisfactory
odour or taste.
ATACAMA Adsorption Dryer
The ATACAMA point of use dryer is designed with reliability at the forefront, has no shuttle valves and uses only positively driven valves. Eliminating any chance of valve failure and extending service periods. The standard unit dries air to a dewpoint of -40C and comes with pre and after filtration. Lower dewpoint models are available on request.
The proven extruded aluminium technology is ideal for an array of applications, including dental, medical, powder coating, printing and laser technology, pneumatic control, plasma cutting and general manufacturing.
The ATACAMA is available from 5cfm to 100cfm and is an off the shelf product for next day delivery.
ATACAMA Principles of Operation
ATACAMA comprises of aluminium top and bottom valve blocks and extruded aluminium chambers filled with desiccant (DRI-ZORB 27).
The air is dried as the air passes through the desiccant bed. One chamber is drying, whilst the other chamber is regenerating using the PSA principle (Pressure Swing Adsorption). The change is automatic and controlled by the digital controller.
A small amount of the dried compressed air is used to regenerate the saturated desiccant bed by expanding the dry air from line pressure to atmospheric pressure removing the moisture absorbed by the desiccant and therefore regenerating the dryer.
ATACAMA Dewpoint control
The ATACAMA dryer has fitted as standard a digital controller and a dewpoint control function. This energy saving system requires only a dewpoint hydrometer probe to be added on the dryer to give full dewpoint control with the dewpoint LED displayed in the top right corner of the control panel.
This smart controller can be added to all makes of dryer as an energy saving option.
ATACAMA-CT
The Atacama CT (Carbon Tower) is a three stage dryer with the CT added after the adsorption dryer. Clean dry air passes through the third stage and adsorbs gases and aerosols dependant on requirements and which zeolites are selected. This makes the Atacama extremely flexible and can be used in many specific applications.
CLASS ‘0’ Oil Free
To achieve Class ‘0’ the air needs to be oil free, this can be achieved with an ATACAMA-CT. With the third tower filled with high quality carbon. Even on a fully oil lubricated screw, vane or piston compressor the ATACAMA-CT will achieve better than ISO 8573-1:2010 Class 1.
This will give a total concentration of oil of less than 0.003 mg/m³, which is significantly less than is normal in atmospheric air in our home and work places. Suitable for food production, medical air and anywhere that oil free air is specified.
BREATHING AIR
The versatile ATACAMA-CT was first designed as a Breathing Air Purifier and to conform to International Breathing Air Standards. In Europe BS EN12021 & EN12021:2014 and CGA G-7.1-2011 Grade D in the USA.
Europe BS EN12021 & EN12021:2014
ATACAMA-CTDesiccant
Tower
Energy Management
Dewpoint Control
DewpointHydrometer
Probe
After Filter For
Particulate Removal
Third Tower For Oil
Removal Class ‘O’ or
Breathing Air Purifier
(Dependant on Zeolites installed)
Standard Diaphragm Valves
(110v or 240v)
Exhaust Muffler
Anodised Aluminium Vessels 16 Bar Rated
Pre-filtration Sub-micron Oil Removal As Standard
Available from 0.2 m³/min to 2.83 m³/min
Desiccant Tower
Energy Management
Dewpoint Control
After Filter For
Particulate Removal
Third Tower For Oil
Removal Class ‘O’ or
Breathing Air Purifier
(Dependant on Zeolites installed)
Standard Diaphragm Valves
(110v or 240v)
Exhaust Muffler
Anodised Aluminium Vessels 16 Bar Rated
Pre-filtration Sub-micron Oil Removal As Standard
DewpointHydrometer
Probe