6
PACKAGING MasterSeal HLM 5000 SL, HLM 5000 S, and HLM 5000 R: 5 gal (18.95 L) pails, 55 gal (208 L) drums; available special order MasterSeal HLM 5000 T: 5 gal (18.95 L) pails MasterSeal 995: 300 ft by 37" (91 by 0.9 m) rolls, yielding 937 ft 2 (87 m 2 ) MasterSeal 977: - 50 mil by 40" by 48" (1.3 mm by 1 m by 1.2 m) sheets, 500 per pallet, yielding 13 1 3 ft 2 (1.2 m 2 ) per sheet or 6,665 ft 2 (619 m 2 ) per pallet. - 120 mil ( 1 8") by 40" by 48" (3 mm by 1 m by 1.2 m) sheets, 500 per pallet, yielding 13 1 3 ft 2 (1.2 m 2 ) per sheet or 6,665 ft 2 (619 m 2 ) per pallet. Liquid, cold-applied elastomeric waterproofing membrane system FoRMeRLy SonoSHieLd ® HLM 5000 07 14 00 Fluid-Applied Waterproofing 7 PRODUCT HIGHLIGHTS Available in standard and high-build systems Waterproofing membrane to prevent water penetration elastomeric accommodates expansion and contraction Wide service-temperature range, making MasterSeal HLM 5000 suitable for all climates Chemical resistance to bacterial attack, select acids, alkalis and salts Seamless cold-applied membrane eliminates lapping, seaming and precutting does not require hot-melt equipment APPLICATIONS Concrete Plywood (exterior) exterior below grade (on masonry, concrete, and incidental metal) Above grade (between two-course concrete and within cavity walls) Parking garages and concrete tanks Plaza decks and malls Fountains and pools Balconies and planters Below-grade slabs Walls and culverts Sea walls, dams and reservoirs MasterSeal ® HLM 5000 DESCRIPTION MasterSeal HLM 5000 is a one-component, moisture-curing, bitumen-modified polyurethane elastomeric waterproofing membrane for exterior below-grade or between-slab applications. it is available in four grades: MasterSeal HLM 5000 SL (self-leveling/squeegee) MasterSeal HLM 5000 S (spray) MasterSeal HLM 5000 T (trowel) MasterSeal HLM 5000 R (roller) YIELD 25–30 ft 2 /gal at 55–65 wet mils (0.61–0.74 m 2 /L at 1.4–1.7 mm wet thickness) 25–30 ft 2 /gal at 45–55 dry mils (0.61–0.74 m 2 /L at 1.1–1.4 mm dry thickness) Coverage may vary with the application technique used. Actual coverage rate and mil thickness depend on finish and porosity of the substrate. STORAGE Store in unopened containers in clean, dry conditions at 40 to 80°F (4 to 27°C). during storage, an easily removed skin of HLM 5000 may form, which does not affect performance of the product. SHELF LIFE – 1 year Pails – 6 Months drums VOC CONTENT – MasterSeal HLM 5000 SL: 183 g/L – MasterSeal HLM 5000 S: 190 g/L – MasterSeal HLM 5000 R: 180 g/L – MasterSeal HLM 5000 T: 132 g/L HOW TO APPLY MASTERSEAL HLM 5000 SURFACE PREPARATION 1. For best results, all concrete deck surfaces should be lightly steel troweled to a flat, uniform surface. A light broom finish is acceptable. new concrete must be properly water cured at least 14 days. Membrane curing compounds must be mechanically removed. Master Builders Solutions by BASF www.master-builders-solutions.basf.us Technical Data Guide Distributed by: BEST MATERIALS ® Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 www.BestMaterials.com Email: [email protected]

Upload: others

Post on 24-Feb-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Packaging•MasterSealHLM5000SL,HLM5000S,andHLM5000R:5gal(18.95L)pails,55gal(208L)drums;availablespecialorder

•MasterSealHLM5000T:5gal(18.95L)pails•MasterSeal995:300ftby371/2"(91by0.9m)rolls,yielding937ft2(87m2)

•MasterSeal977:-50milby40"by48"(1.3mmby1mby1.2m)sheets,500perpallet,yielding131⁄3ft2(1.2m2)persheetor6,665ft2(619m2)perpallet.

-120mil(1⁄8")by40"by48"(3mmby1mby1.2m)sheets,500perpallet,yielding131⁄3ft2(1.2m2)persheetor6,665ft2(619m2)perpallet.

Liquid, cold-applied elastomeric waterproofing membrane systemFoRMeRLySonoSHieLd®HLM5000

071400Fluid-applied Waterproofing7

PRODUcT HigHLigHTS•Availableinstandardandhigh-buildsystems•Waterproofingmembranetopreventwaterpenetration

•elastomericaccommodatesexpansionandcontraction

•Wideservice-temperaturerange,makingMasterSealHLM5000suitableforallclimates

•Chemicalresistancetobacterialattack,selectacids,alkalisandsalts

•Seamlesscold-appliedmembraneeliminateslapping,seamingandprecutting

•doesnotrequirehot-meltequipment

aPPLicaTiOnS•Concrete•Plywood(exterior)•exteriorbelowgrade(onmasonry,concrete,andincidentalmetal)

•Abovegrade(betweentwo-courseconcreteandwithincavitywalls)

•Parkinggaragesandconcretetanks•Plazadecksandmalls•Fountainsandpools•Balconiesandplanters•Below-gradeslabs•Wallsandculverts•Seawalls,damsandreservoirs

MasterSeal® HLM 5000

DeScRiPTiOnMasterSealHLM5000isaone-component,moisture-curing,bitumen-modifiedpolyurethaneelastomericwaterproofingmembraneforexteriorbelow-gradeorbetween-slabapplications.itisavailableinfourgrades:MasterSealHLM5000SL(self-leveling/squeegee) MasterSealHLM5000S(spray)MasterSealHLM5000T(trowel) MasterSealHLM5000R(roller)

YieLD 25–30ft2/galat55–65wetmils(0.61–0.74m2/Lat1.4–1.7mmwetthickness)

25–30ft2/galat45–55drymils(0.61–0.74m2/Lat1.1–1.4mmdrythickness)

Coveragemayvarywiththeapplicationtechniqueused.Actualcoveragerateandmilthicknessdependonfinishandporosityofthesubstrate.

STORage Storeinunopenedcontainersinclean,dryconditionsat40to80°F(4to27°C).duringstorage,aneasilyremovedskinofHLM5000mayform,whichdoesnotaffectperformanceoftheproduct.

SHeLF LiFe–1yearPails–6Monthsdrums

VOc cOnTenT–MasterSealHLM5000SL:183g/L–MasterSealHLM5000S:190g/L–MasterSealHLM5000R:180g/L–MasterSealHLM5000T:132g/L

HOW TO aPPLY MaSTeRSeaL HLM 5000SURFace PRePaRaTiOn

1.Forbestresults,allconcretedecksurfacesshouldbelightlysteeltroweledtoaflat,uniformsurface.Alightbroomfinishisacceptable.newconcretemustbeproperlywatercuredatleast14days.Membranecuringcompoundsmustbemechanicallyremoved.

MasterBuildersSolutionsbyBASFwww.master-builders-solutions.basf.us

Technical Data Guide

Distributed by: BEST MATERIALS ® Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 www.BestMaterials.com Email: [email protected]

High-Build Standard System System

Hardness,Shoreoo n/A 85 ASTMC836

Viscosity, poise BrookfieldHLM5000SL 125HLM5000S 450HLM5000R 800HLM5000T 4,000

Tensile strength, psi(MPA) 200(1.4) 150(1.0) ASTMd412

average elongation, % 3001 600 ASTMd412

100% modulus,psi(Mpa) 80(0.6) 80(0.6) ASTMd412

Moisture-vapor permeability, 0.075 0.1 ASTMe96dryperms

crack bridging test, Passed1/4"; Passed1⁄16"; ASTMC836cycled10timesper nolossofbondor nolossofbond24hoursat15°F(-9°C) orcrackingexhibited orcrackingexhibited

extensibility after heat aging nocracking ASTMC836

adhesion in peel,lbs/in 5 ASTMC836(1lb/inminimum)

Weight loss, %(20%max) 16 ASTMC836

Resultsshownaretypicalbutarenotintendedasperformancecriteriaforon-siteinstalledmaterial.1Testedindirectionofgreatestelongationoffabric

elongation, % ASTM5034Machinedirection 54 Crossdirection 147

grab breaking, lbs ASTM5034Machinedirection 54Crossdirection 32

Mullen burst,psi 70

Weight,lbs/ft250mil 0.188120mil 0.428

Burst strength,psi(MPa) 175 ASTMd2529

Puncture resistance,in-lbs 45 ASTMd781

Testresultsareaveragesobtainedunderlaboratoryconditions.Reasonablevariationscanbeexpected.

Test Data

PRoPeRTy VALue

PRoPeRTy VALue

Typical Properties

Minimum recovery,% 90

Swelling in water, nil3daysatroomtemperature

Service temp. range, °F(°C) Minimum -40(-40) Maximum 120(49)

Width,in Minimum 371/2 Maximum 381/2

Length,ft 300

Thickness,in (FTM-5136)0.024 (-0.0,+0.002)

nominal weight,oz/yd2 2.13

construction,in2 34by30

Yarn denier 70

PRoPeRTy ReSuLTS TeSTMeTHod

PRoPeRTy ReSuLTS TeSTMeTHod

PRoPeRTy ReSuLTS TeSTMeTHod

HLM5000

HLM5000(self-levelinggrade)

MasterSeal995

MasterSeal977

MASTeRSeAL995

Technical Data compositionMasterSealHLM5000isabitumen-modifiedpolyurethane.

compliances•ASTMC836•nationalstandardofCanada37.58-M86developedbyCGSB

TechnicaldataGuideMasterSeal® HLM 5000

VenT,dRAinPiPe,AndPoSTPeneTRATionSCleanmetalsurfacestobrightmetalandprimewithaqualityrust-inhibitingmetalprimerfollowedbyMasterSealP173orP176.Removedust,debrisandanyothercontaminantsfromvoids.Sealwiththeappropriatesealant.

aPPLicaTiOnAtestapplicationisalwaysrecommendedbeforeproceedingwithentireapplication.noTe:Finishcoatmustbeappliedinapinhole-free,continuousmembraneforwaterproofingintegrity.

STAndARdSySTeM1.SelectthegradeofMasterSealHLM5000thatbestmeetsindividualjobrequirements.useMasterSealHLM5000Tfortrowelapplication,MasterSealHLM5000Sforsprayapplication,MasterSealHLM5000RforrollerapplicationorMasterSealHLM5000SLforsqueegeeapplication.

2.Forhorizontalapplications,emptycontentsofpailandspreadimmediatelytoensureworkability.Bestresultsareobtainedbymarkingoff125ft2(11.61m2)areasandevenlyspreadingthecontentsofa5gallon(18.93L)unitwitharubber-edgednotchedsqueegee.Repeattheaboveprocedureuntiltheentiresurfaceiscovered.

3. Forverticalapplications,applybytrowel,rollerorsprayattherateof25ft2/gallon(0.6m2/L).Bestresultsareobtainedbymarkingoff125ft2(11.6m2/L)andevenlyapplyingthecontentsofa5gallon(18.93L)pail.

4.Verifytheappliedthicknesswithawetmilgaugeastheworkprogresses.

5.Theintegrityofthecuredmembraneonahorizontalsurfacemaybeverifiedbydammingtheentireareaandfloodingwithwatertoaminimumdepthof2"(51mm)andallowingthewatertostandfor24–48hours.Visuallyinspectthebottomsurfacetocheckforanywaterpenetration.ifrepairsarenecessary,theareashouldbedrainedandallowedtodrybeforereapplyingMasterSealHLM5000.Afterreapplication,theareashouldbetestedagainformembraneintegrity.

HiGH-BuiLdSySTeMConcreteapplication:Apply60wetmilsofMasterSealHLM5000,followedbysettingMasterSeal995reinforcingfabricintothewetmaterial.overlapallseamsaminimumof3"(76mm).Additionalmaterialmayberequiredtoproperlyembedthereinforcingfabricwhereitoverlaps.Allowthefirstcoattocureovernightandfollowwithasecond60wet-milapplicationofMasterSealHLM5000.

Plywoodapplication:AllplywoodconstructionmustcomplywithAPA(AmericanPlywoodAssociation)standards.CaulkalljointswithaMasterBuildersSolutionssealantandthenproceedwiththeMasterSealHLM5000high-buildsystem.

SPRAyequiPMenTForsprayequipmentrecommendations,consulttheequipmentmanufacturer.

cURingAppreciablepropertiesdevelopwithin24–48hoursat75°F(24°C)and50%relativehumidity.ProtectMasterSealHLM5000fromtrafficduringcuring.

DRainage anD PROTecTiOn1.Forprotectionduringbackfillandwherehydrostaticpressureisanticipated,usetheappropriateMasterSeal975drainBoardSystemforinstallationinstructions.

2. Forprotectionduringbackfillonly,installprotectionboardassoonaspossiblefollowingcureofMasterSealHLM5000.

cLean UPCleanalltoolsandequipmentimmediatelyafterapplicationwithMasterSeal990.

HOW TO aPPLY MaSTeRSeaL 977SURFace PRePaRaTiOn

1.Waterproofingmembranesmustbeprotectedagainsttear,puncture,andotherabusesduringplacementofconcretewearingslabsandreinforcingsteel.Theyshouldalsobeprotectedfromjobsitetrafficandbackfillingoperations.

2.Allspecificationscallingformembranewaterproofingshouldalsorequireprotectionofmembraneasanintegralpartoftheoverallwaterproofingsystem.

2.Forextremelyporousblock:PrimewithacoatofMasterSealHLM5000dilutedupto25%withMasterSeal990orxylene.orapplyapargecoatofMasterSeal581attherateofapproximately400ft2(37.2m2)perbagandallowtocureaminimumof7daysbeforeapplyingMasterSealHLM5000.

3.Removedust,dirtandothercontaminantsjustbeforeorduringapplication.Surfacesmustbedryatthetimeofapplication.

4.Air-voidpockmarksorhoneycombsmustbeopeneduptoallowMasterSealHLM5000tofillthecavitiescompletely.Airentrapmentwithinvoidsmaycauseblisters.extremecasesmayrequireadditionalrepair.

PReSTRiPing1.Beforeapplyingthefinalmembrane,alljoints,cracksandopeningsaroundprotrusionsmustbesealedbycaulkingorprestriping(apreliminarycoatingofMasterSealHLM5000appliedwithatrowelorstiff-bristledbrush).Allowtodryovernightbeforeapplyingfinalmembrane.

2.Whenthefinalmembraneisapplied,theoverallthicknessoverjointsandcracks,atcovesandaroundpenetrationsshouldbeapproximately100wetmils(2.5mm)onthestandardsystem.

STATiCJoinTSAndCRACkSJointsandcrackslessthan1⁄16"

(1.6mm)should

befilledbyprestriping.Applymaterialsoitbothfillsandoverlapsthejointorcracktoawidthof4"(102mm)oneachside.

WoRkinGoRexPAnSionJoinTSAlljointsover1⁄8"(3mm)mustbesealedwithaMasterBuildersSolutionsurethanesealant.Anyworkingjointlessthan1⁄8"(3mm)shouldberoutedtoaminimumof1/4"(6mm)andfilledwithasealant.Preventthewaterproofingmembranefromadheringtothejointsealant,whichcouldcausesealantormembranefailure,byapplyingacoatofwaxorbondbreakertapeoverthecuredsealantandthenprestriping.

unCoATedMeTALSuRFACeSRemovedust,debris,andanyothercontaminantsfromvent,drainpipeandpostpenetrations,regletsandothermetalsurfaces.CleansurfacestonearwhiteperSSPC-nACe2andprimeimmediatelywithMasterSealP173.ProvideappropriatecantwithMasterSealnP1™

ornP2™sealantstoeliminate90°angles.

MasterBuildersSolutionsbyBASFwww.master-builders-solutions.basf.us

aPPLicaTiOn installoverlappingMasterSeal977protectionboardassoonaspossiblefollowingcureoftheliquidmembrane.ProtectMasterSealHLM5000fromtrafficbeforeplacementofprotectionboard.MasterSealHLM5000mustbecuredbeforeinstallationofanytopping.

FOR BeST PeRFORManceMASTeRSeALHLM5000

•ApplyMasterSealHLM5000whensubstratesaredryandairtemperaturesare40to90°F(4to32°C);forapplicationattemperaturesbelow40°F(4°C),consultTechnicalServices.

•TemperaturesinfluenceviscosityandhandlingcharacteristicsofMasterSealHLM5000:heatincreasesandcolddecreasestheflow.keepMasterSealHLM5000coolinhotweatherandwarmincoldweather.

•Avoidapplicationwheninclementweatherispresentorimminent.

•donotapplytoreinforcingbarsortowetorcontaminatedsurfaces.

•donotdirectlyheatcontainerswithflame,stove,hotplateoroven.

•PatchallvoidsanddeepdepressionsinsubstrateswithappropriatepatchingmaterialbeforeapplyingMasterSealHLM5000.

•useMasterSeal550underthin-settileapplications.•BeforeapplyingMasterSealHLM5000,damalldrainsanddrainopenings.

•Carefullyworkmaterialoverirregularconcretetoavoidpinholesandholidays.

•ProtectMasterSealHLM5000coatedsurfacesfrompuncturewithprotectionboarduntilrequiredtoppingorbackfillisplaced.

•notintendedasanexposedorwearingsurface.•donotusewhereasolventodorisobjectionable,e.g.,nearareaswherefoodpreparationorprocessingoccurduringtheapplication.

•SpecifywetorpapercuringforconcretetobecoatedwithMasterSealHLM5000;avoidusingliquidcuringcompounds.

•inhorizontalapplicationsconcretemustbesloppedtodraintoavoidpondingwateronthesurfaceofMasterSealHLM5000

•WhenusingdrainagematdirectlyoverMasterSealHLM5000,alayerof6milpolyethylenesheetingshouldbeusedbetweentheMasterSealHLM5000andthedrainagemat.

MASTeRSeAL977•StoreMasterSeal977onaflatsurfaceandkeepitdry;donotremoveshrinkwrapuntilimmediatelybeforeuse.

•ifboardisexposedtoprolongedperiodsofwaterimmersionorexcessivehumidity,itmaycurlorwrinkle.

•MasterSeal977tobecoveredwithaconcretewearingcoursemustbesecurelyattachedtomembrane.

GeneRAL•Properapplicationistheresponsibilityoftheuser.FieldvisitsbyBASFpersonnelareforthepurposeofmakingtechnicalrecommendationsonlyandnotforsupervisingorprovidingqualitycontrolonthejobsite.

HeaLTH, SaFeTY anD enViROnMenTaL Read,understandandfollowallSafetydataSheetsandproductlabelinformationforthisproductpriortouse.TheSdScanbeobtainedbyvisitingwww.master-builders-solutions.basf.us,[email protected](800)433-9517.useonlyasdirected.For medical emergencies only, call chemTrec® 1(800)424-9300.

LiMiTeD WaRRanTY nOTice BASFwarrantsthisproducttobefreefrommanufacturingdefectsandtomeetthetechnicalpropertiesonthecurrentTechnicaldataGuide,ifusedasdirectedwithinshelflife.Satisfactoryresultsdependnotonlyonqualityproductsbutalsouponmanyfactorsbeyondourcontrol.BASFMAkeSnooTHeRWARRAnTyoRGuARAnTee,exPReSSoRiMPLied,inCLudinGWARRAnTieSoFMeRCHAnTABiLiTyoRFiTneSSFoRAPARTiCuLARPuRPoSeWiTHReSPeCTToiTSPRoduCTS.ThesoleandexclusiveremedyofPurchaserforanyclaimconcerningthisproduct,includingbutnotlimitedto,claimsallegingbreachofwarranty,negligence,strictliabilityorotherwise,isthereplacementofproductorrefundofthepurchaseprice,atthesoleoptionofBASF.Anyclaimsconcerningthisproductmustbereceivedinwritingwithinone(1)yearfromthedateofshipmentandanyclaimsnotpresentedwithinthatperiodarewaivedbyPurchaser.BASFWiLLnoTBeReSPonSiBLeFoRAnySPeCiAL,inCidenTAL,ConSequenTiAL(inCLudinGLoSTPRoFiTS)oRPuniTiVedAMAGeSoFAnykind.

Purchasermustdeterminethesuitabilityoftheproductsfortheintendeduseandassumesallrisksandliabilitiesinconnectiontherewith.ThisinformationandallfurthertechnicaladvicearebasedonBASF’spresentknowledgeandexperience.However,BASFassumesnoliabilityforprovidingsuchinformationandadviceincludingtheextenttowhichsuchinformationandadvicemayrelatetoexistingthirdpartyintellectualpropertyrights,especiallypatentrights,norshallanylegalrelationshipbecreatedbyorarisefromtheprovisionofsuchinformationandadvice.BASFreservestherighttomakeanychangesaccordingtotechnologicalprogressorfurtherdevelopments.ThePurchaseroftheProduct(s)musttesttheproduct(s)forsuitabilityfortheintendedapplicationandpurposebeforeproceedingwithafullapplicationoftheproduct(s).Performanceoftheproductdescribedhereinshouldbeverifiedbytestingandcarriedoutbyqualifiedexperts.

TechnicaldataGuideMasterSeal® HLM 5000

Dynamic crack Detail

asphalt Pavement Topping/expansion Joint

Vent/Drain/Pipe/Post Penetration Detail

Split Slab with cant DetailWaterproofing at Bi-Level Drain

MasterBuildersSolutionsbyBASFwww.master-builders-solutions.basf.us

inside corner Detail (Static)

Waterproofing Foundation Walls

expansion Joint Detail

Static crack/Prestripe Detail

©2014BASFCorporationFormno.1017900rev01/14

BaSF corporation 889ValleyParkdrive,Shakopee,Mn55379 customer Service 1(800)433.9517construction Systems www.master-builders-solutions.basf.us Technical Service 1(800)243.6739

TechnicaldataGuideMasterSeal® HLM 5000

Distributed by: BEST MATERIALS ® Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 www.BestMaterials.com Email: [email protected]