td 100 tee probe disinfector accessories - ge healthcare/media/documents/marketopd... · • td-8...

6
TD-8 ® High-Level Disinfectant Single-use, 0.59% Ortho-phthalaldehyde based, high-level disinfectant Use a fresh TD-8 bottle (for each disinfection cycle) eliminating the need for continuous MRC testing TD-8 has been tested to effectively kill potentially harmful microorganisms without damaging the TEE probe 32 bottles/case TD 100 TEE Probe Disinfector Accessories TEEZyme™ TEE Probe Enzymatic Sponge Only TEE probe-specific sponge on the market Proprietory blend of enzymes designed to break down all bio burden Aids in the solubilization of polysaccharides and removal of biofilm allowing for high-level disinfectants to kill Individually wrapped for single use to help decrease cross contamination • Lint-Free/Latex-Free/Dust-Free Optional Sponge Caddy (E8364BP) Dimensions - 12.5 in (W) x 16 in (H) x 5 in (D) E8364BM - TEEZyme Sponge E8364BP - TEEZyme Sponge Caddy GE Healthcare E8364BE - TD-8 High-Level Disinfectant The TD 100 ® Automated TEE Probe Disinfector is designed to provide high-level disinfection of transesophageal echocardiogram (TEE) ultrasound probes. GE offers a wide array of accessories for the TD 100 Disinfector to cover your needs from TEE probe pre-cleaning to storage.

Upload: dinhdieu

Post on 15-Sep-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TD 100 TEE Probe Disinfector Accessories - GE Healthcare/media/Documents/MarketoPD... · • TD-8 has been tested to effectively kill potentially harmful microorganisms without damaging

TD-8® High-Level Disinfectant• Single-use, 0.59% Ortho-phthalaldehyde based,

high-level disinfectant

• Use a fresh TD-8 bottle (for each disinfection cycle)eliminating the need for continuous MRC testing

• TD-8 has been tested to effectively kill potentiallyharmful microorganisms without damaging theTEE probe

• 32 bottles/case

TD 100 TEE Probe Disinfector Accessories

TEEZyme™ TEE Probe Enzymatic Sponge• Only TEE probe-specific sponge on the market

• Proprietory blend of enzymes designed to breakdown all bio burden

• Aids in the solubilization of polysaccharidesand removal of biofilm allowing for high-leveldisinfectants to kill

• Individually wrapped for single use to help decreasecross contamination

• Lint-Free/Latex-Free/Dust-Free

• Optional Sponge Caddy (E8364BP) Dimensions -12.5 in (W) x 16 in (H) x 5 in (D)

E8364BM - TEEZyme Sponge

E8364BP - TEEZyme Sponge Caddy

GE Healthcare

E8364BE - TD-8 High-Level Disinfectant

The TD 100® Automated TEE Probe Disinfector is designed to provide high-level disinfection of transesophageal echocardiogram (TEE) ultrasound probes.

GE offers a wide array of accessories for the TD 100 Disinfector to cover your needs from TEE probe pre-cleaning to storage.

Page 2: TD 100 TEE Probe Disinfector Accessories - GE Healthcare/media/Documents/MarketoPD... · • TD-8 has been tested to effectively kill potentially harmful microorganisms without damaging

PullUp™ TEE Probe Bio-Barrier Disposable Sleeve• Used to cover the TEE probe for transportation to

the cleaning station

• Completely covers the insertion tube of the TEEultrasound probe

• Designed to prevent enzymatic solution andnon high-level disinfected probe componentcross contamination

• 100 sleeves/box

PullUp TEE Probe Disposable Cover• Use a PullUp TEE probe cover to protect a high-level

disinfected probe before insertion into the TPorterTransportation Case

• The PullUp TEE Prove Cover protects fromcross contamination

• 100 covers/box

QwikDry™ Probe Drying Cloths• Single-use, individually packaged irradiated drying

cloth can be used with any Ultrasound probe

• Size: 6 in x 6 in

• Lint-Free

• Non-abrasive surface

• Optional QwikDry Caddy (E8364DG) Dimensions -10.5 in (W) x 6.75 in (H) x 5.5 in (D)

E8364DF - QwikDry Probe Drying Cloth

E8364DG - QwikDry Cloths Caddy

E8364DZ - PullUp Bio-Barrier Sleeve

E8364DY - TEE Probe Cover

Page 3: TD 100 TEE Probe Disinfector Accessories - GE Healthcare/media/Documents/MarketoPD... · • TD-8 has been tested to effectively kill potentially harmful microorganisms without damaging

TPorter™ TEE Ultrasound Probe Transportation and Procedure Case

• Designed to effectively and securely transport TEEultrasound probes

• Minimizes the risk of probe damage and reduce staffexposure to potentially hazardous biological materialwhen used as a dedicated transportation device

Designed with a variety of molded compartments to accommodate accessories:

• Bite block(s)

• A PullUp™ Bio-Barrier Sleeve

• TEEZyme™ enzymatic sponge

• Optional TPorter (E8364DV) Dimensions -27.5 in (L) x 19 in (H) x 3.75 in (D)

Red and Green Banding System helps to easily identify the probes current condition• T-Porter is constructed of rugged polycarbonate

with a slide locking lid and a color indicator band(Catalog E8364DX purchased separately) to identifyTEE ultrasound probe status

The delicate nature of a TEE probe requires a solution that securely and adequately holds the TEE ultrasound probe during transport.

A cleaned and high-level disinfected TEE Probe covered by the PullUp TEE Probe Cover would be transported inside

the TPorter sealed with a green band.

Once the probe has been soiled, a red band, held within the TPorter compartment, will be placed on the case to identify the

presence of a potentially biohazardous material.

• Cleaning of TPorter, between procedures, can beaccomplished with several types of hard surfacehigh-level disinfectants, such as Solucide, or othernon-alcohol based hard surface disinfectants

E8364DV - TPorter TEE Ultrasound Probe Transportation and Procedure Case

Green Band

Red Band

Page 4: TD 100 TEE Probe Disinfector Accessories - GE Healthcare/media/Documents/MarketoPD... · • TD-8 has been tested to effectively kill potentially harmful microorganisms without damaging

Medizime® LF Enzymatic Cleaner• The use of enzymatic cleaners, like Medizime LF,

by infection control and ultrasound professionalsis a critical step in instrument decontamination

• Saves Time: Once diluted, only 2-3 minutesof contact time is needed for fiber opticinstrumentation

• Easy to use: Packaged in gallon containers with anaccurate 1 oz. pump dispenser

• Cost Efficient: Concentrated yet mild in pH

• Environmentally Friendly: 100% biodegradable andphosphate free

• 4 gallons/case

E8364BN - Master Spill Kit

E8364DW - Medizime LF Enzymatic Cleaner

Master Spill Kit • Master Spill Kit is compact and can be placed near

the point of use as per the JCAHO HazardousMaterial Plan

• Each kit contains materials to effectively neutralize,protect and clean-up small spills

The Kit includes:

• 5 oz. bottle of green Z™ solidifier

• Nitrile gloves

• 2 oz. of Glycinex™ neutralizer

• Ventilated goggles

• Glutaraldehyde respirator

• Scoop/scraper (2)

• 30 gallon bag

• Instructions

Page 5: TD 100 TEE Probe Disinfector Accessories - GE Healthcare/media/Documents/MarketoPD... · • TD-8 has been tested to effectively kill potentially harmful microorganisms without damaging

Thermal Printer Paper• Thermal paper for the TD 100

Nephros UltrafilterWaterborne bacteria are an ever-growing challenge in healthcare facilities. Rinse water quality can affect a properly high-level disinfected medical device by introducing bacteria, viruses and endotoxins.

• The nephros DSU-H filter is a patented, dual-stage,hollow-fiber ultrafilter that retains bacteria, viruses,and endotoxins found in water.

• All filtration occurs in the first stage of the filterwhile the second stage serves as a redundantsafety filter.

• It is recommended the Nephros Ultrafilter bechanged at least every six months,Catalog # E8364DJ (includes 2 filters)

Filter Membrane Medisulfone®

Material Polysulfone

Pore Size 5 nm

Bacteria Retention >1011 (B.diminuta)

Virus Retention >108 (PhiX-174)

Endotoxin Retention >105 EU/ml

Dimensions 13” L x 2.5” D

Expected Life Up to 6 months

E8364BG - Thermal Paper Roll

Page 6: TD 100 TEE Probe Disinfector Accessories - GE Healthcare/media/Documents/MarketoPD... · • TD-8 has been tested to effectively kill potentially harmful microorganisms without damaging

Imagination at work

Product may not be available in all countries and regions. Full product technical specification is available upon request. Contact a GE Healthcare Representative for more information. Please visit www.gehealthcare.com/promotional-locations

Data subject to change. © 2017 General Electric Company. October, 2017/JB42096US(3)

GE, the GE Monogram and imagination at work are trademarks of General Electric Company.

TD 100, TD-8, TEEZyma, Qwikdry and TPorter are trademarks of CS Medical. Glycinex is a trademark of AirClean Systems. Medizimo is a trademark of Medical Chemical. PullUp is a trademark of Protek Medical.

Reproduction in any form is forbidden without prior written permission from GE. Nothing in this material should be used to diagnose or treat any disease or condition. Readers must consult a healthcare professional.

Catalog # Description

E8364BE TD-8® OPA High Level Disinfectant for TD 100 Disinfector

E8364BM TD 100 TEEZyme Contoured Enzymatic Sponge for TEE probes, 100/box

E8364BP TD 100 TEEZyme Sponge caddy

E8364DF TD 100 QwikDry Ultrasound Probe Drying Cloth, 100/case

E8364DG TD 100 QwikDry Caddy

E8364DV TPorter TEE Ultrasound ProbeTransportation and Procedure Case

E8364DX TPorter Tie Bands, 200/pack (100-red, 100-green)

E8364DY PullUp TEE Probe Cover 100/box

E8364DZ PullUp Bio-Barrier Sleeve, 100/box

E8364BN TD 100 Master Spill Kit

E8364DW Medizime® LF Enzymatic Cleaner, 1 gallon bottle, 4 gallons/case

E8364BG TD 100 Thermal Paper Roll (each)

E8364BH Glycinex, 2 oz. packets (24/case)

E8364DH TD 100 Nephros Starter Kit (includes 2 filters and installation hardware)

E8364DJ TD 100 Nephros Annual Maintenance Kit (includes 2 filters)

Ordering is easy

In the U.S.Phone: 866-281-7545 – Opt. 1, 2, 1, 2Fax: 877-279-6990Email: [email protected]

Shop Online:

www.gehealthcare.com/accessories

Glycinex Neutralizer for the AC-DS-03 High-Level Disinfectant Neutralizer Station

• Glycinex completely neutralizes disinfectant in 5minutes. No overnight waiting to dispose of waste

• Each Glycinex packet contains a pre-measuredvolume of neutralizer. A noticeable color change willoccur during deactivation

• Glycinex converts OPA into a non-toxic, pH-neutralcompound. It minimizes time and costs associatedwith hazardous waste disposal

• Does not contain any corrosive acids or unstableoxidizers. Heating is not required. Larger volumesof OPA based products can be safely neutralizedwithout dangerous heat build-up

• Not harmful to active bacteria used in treatingsewage and sewer sludge

• One pack of Glycinex (2 oz) will last four TD100 disinfection cycles. After four cycles, theNeutralization Station (AC-DS-03) will automaticallypurge all the liquid

E8364BH - Glycinex, 2 oz. packets