tc550/oc500 fingerprint & card time attendance and access ... · tc550 1 2 3 5 6 7 8 9 10 12 4...

1
TC550 1 2 3 5 6 7 8 9 10 12 4 11 OC500 1 2 3 5 6 7 8 9 11 12 4 1.LCD 2.Loudspeaker 4.0-9 Num. Key 5.State Key(Clock In)/Page Up 6.State Key(Clock Out)/Page Down Press [OK] about 3 seconds to turn on the device, press [M] key to enter the system menu. Menu list: User System Info User, FP, Log, Serial,FirmVer Delete Group setup Admin Setup Admin Clear Setup Hardware Test Keypad, LCD, Voice, Sensor, Flash System Time Language Net Precision Volume Auto Off Auto Update Image Disp. Log Setup Log Alert Re-Verify Verify Mode USB Flash New Log Backup All Logs Backup User Reco! User Backup IP Address Subnet Mask Gateway IP MAC Address Workcode Scope Dev ID Unlock/Ring Mode Server IP Server Port Enroll TC550/OC500 Fingerprint & Card Time Attendance and Access Control Operation Guide Product Appearance Menu List Operation Guide Other Setup Illustration for placing finger Wiring Diagram Place finger in the center of the sensor. Correct method : Incorrect method : Admin Setup: Admin(Administrator) has all the privileges of the machine. Please pay attention to the admin setup. Admin Setup ID 008101 Esc-C Add-OK Admin Setup 008101 No-C Yes-OK Admin Setup Esc-C Add-OK Admin Setup ID 000000 MENU User Setup USB Flash User Admin Setup Admin Clear [M] Select [User] [OK] Selelct [Admin Setup] [OK] [OK] [OK] [OK] Setup successful IN 09 : 00 26 10-11-17 WED Input Admin ID [OK] Enroll FP Place Finger #2 Enroll FP Place Finger #1 Enroll fingerprint Enroll FP 008101-1 Sav-OK Press [OK] to save Enroll 1/2 Password/Card Esc-C Set-OK Select [FP] [OK] FP Enroll Fingerprint : Place finger on the sensor twice to enroll fingerprints. Enroll Password: Password length: 0-999999. Enroll PWD PWD ID ****** Esc-C Set-OK Input password Enroll PWD 008101-P Cancel-C Sav-OK Press [OK] to save [OK] [OK] [OK] [OK] Enroll PWD PWD ID ****** Confm ****** Input password again Enroll FP 1/2 Password /Card Esc-C Set-OK Select [Password] Enroll Card: Enroll Card Swipe card! Enroll Card 008101-C Cancel-C Sav-OK Enroll FP 1/2 Password/ Card Esc-C Set-OK [OK] Select [Card] Swipe the card Press [OK] to save [OK] Enroll ID 008101 Esc-C Set-OK IN 09 : 00 26 10-11-17 WED MENU User Setup USB Flash User Enroll Delete Verify Mode [M] Select [User] [OK] Select [Enroll] [OK] Input user ID Enroll User: Each user can register two fingerprints, one password and one card. Explanation 1 Item Factory default setting 1-99999999 Device ID of the unit which is required in software communication Dev ID: Tips: WorkCode indicates the work typeeasily distinguishes which attendance record is related to which work type. Explanation Max 999999 Min 0 Item Factory default setting 0-999999 Valid scope for the Workcode WorkCode: Item Explanation Factory default setting Any RF+PW RF+FP PW+FP Fingerprint only, Card only or ID+Password only It requires both Card and Password verification together It requires both Card and Fingerprint verification together It requires both Password and Fingerprint verification together Enter the user ID first, then verify the fingerprint Any ID+FP Verify Mode: TCP/IP Power G-LED R-LED D0 D1 W0 12V OUT DOOR OPEN W1 12V IN COM NO NC GND GND U Disk Mini USB Flash Memory USB TCP/IP 3.FN key (The function with mark in the menu is for the specific model unit. Please follow as actual product’s menu. ) (ID number range:0-999999) Tips: Group setup is used for managing the access control privileges. Each group can contain 4 time zones.The default setting: G01. Explanation G01 Item Factory default setting G00 G01 G02-16 The user in Group00 can not open the door The user in Group01 can open the door anytime It is according to the Group & Time zone setting which can be set through the software Group Setup: V1.2 M→[Setup]→[OK]→[System]→[OK]→[Dev ID]→[OK]→Input the device’s ID →[OK]→[C]→[OK]. M→ [Setup]→[OK]→[System]→[OK]→[WorkCode Scope]→[OK] →Input Max→[OK]→Input Min→[OK] →[C]→[OK]. M→[User]→[OK]→[Verify Mode]→[OK]→[OK]→Input employee ID→[OK]→ Use [IN/ ]/[OUT/ ] to select ‘ANY/RF+FP/PW+FP/RF+PW/ID+FP’ →[OK]→[OK]. Explanation Item Factory default setting Server Mode 192.168.0.218 255.255.255.0 192.168.0.1 192.168.0.7 5010 Mode IP Address Subnet Mask MAC Address Gateway IP Server IP Server Port Net: M→ [Setup][OK][System]→[OK]→[Net]→[OK]→to select [Mode/IP Address/Subnet Mask /MAC Address/Gateway IP/Server IP/Server Port]→[OK]→Modify parameters→[C][OK]. M→[User]→[OK]→[Group Setup]→[OK]→[OK]→ Input employee ID→[OK]→Input the group ID→[OK]→[OK]. Explanation Related Language Item Factory default setting Language Contains 11 languages: ENG(English), FRCH(French), GERM(German), SPAN(Spanish), PTG(Portuguese), ITA(Italian), BULG(Bulgarian), SLVK(Slovak), HUNG(Hungarian), SLVN(Slovenian), TURK(Turkish) Language: M→[Setup]→[OK]→[System]→[OK]→[Language]→[OK]→ Use [IN/ ]/[OUT/ ] to select ENG/FRCH/GERM/...→[OK]→[C]→[OK]. Explanation Item Precision, Volume, Auto off, Auto Update, Image Disp., Log Alert, Re-Verify Place finger flat on the sensor surface. Sliding, Rolling or Moving finger during the enrollment process. Do not remove finger during the enrollment process. Using the tip of your finger. A Standard USB flash drive with a maximum capacity to 2GB of RAM is required. TCP/IP Server mode: Common network mode TCP/IP Client mode: Only communicate with the PC which has static IP Set terminal IP address when communication of TCP/IP, IP address must be a static IP address Subnet Mask of the LAN Unique Physical address of the network moudle. This setting can not be modified. Default Gateway of the LAN The IP address of the Sever Machine when using Client Mode TCP/IP communication. It’s the Software Port number used when the read is configured for TCP/IP communication Image Disp. The duration of time in which the terminal will ignore repeated attempts for authentication. [No]: Disable the function; Max. value is 250 min. Re-Verify Auto update means the previous lower quality fingerprint template will be automatically replaced by the new higher quality one during fingerprint verification. Choose to display the fingerprint image on the screen during the verification process. [Yes] - show fingerprint image, [No] - not show fingerprint image Set the time duration for an idle clock to go into sleep mode. No-[Not Off], 250min-[Max Time]. Set the terminal voice volume. 0-[mute], 5-[Max]. Set terminal fingerprint matching precision. 0-[Normal],1-[Good], 2-[Exact]. Precision Volume Auto off Log Alert Auto Update The terminal will alarm when the memory capacity is less than the [Log Alert] value.[No]-Not alarm, Max. value 5,000. Wiegand Output Wiegand Input

Upload: others

Post on 22-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TC550/OC500 Fingerprint & Card Time Attendance and Access ... · TC550 1 2 3 5 6 7 8 9 10 12 4 11 OC500 1 2 3 5 6 7 8 9 11 12 4 1.LCD 2.Loudspeaker 4.0-9 Num. Key 5.State Key(Clock

TC550

1

2

3 5 6 7

8

9

10

12

4

11

OC500

1

2

3 5 6 7

8

9

11

12

4

1.LCD2.Loudspeaker

4.0-9 Num. Key5.State Key(Clock In)/Page Up6.State Key(Clock Out)/Page Down

Press [OK] about 3 seconds to turn on the device, press [M] key to enter the system menu. Menu list:

User

System Info User, FP, Log, Serial,FirmVer

Delete

Group setup

Admin Setup

Admin Clear

Setup

Hardware Test Keypad, LCD, Voice, Sensor, Flash

System

Time

Language

Net

Precision

Volume

Auto OffAuto Update

Image Disp.

Log SetupLog Alert

Re-Verify

Verify Mode

USB Flash

New Log Backup

All Logs Backup

User Reco!

User Backup

IP Address

Subnet Mask

Gateway IP

MAC AddressWorkcode Scope

Dev ID

Unlock/Ring

Mode

Server IP

Server Port

Enroll

TC550/OC500 Fingerprint & Card Time Attendance and Access Control Operation Guide

Product Appearance Menu List

Operation Guide

Other Setup

Illustration for placing finger

Wiring Diagram

Place finger in the center of the sensor.

Correct method : Incorrect method :

Admin Setup: Admin(Administrator) has all the privileges of the machine. Please pay attention to the admin setup.

Admin Setup ID 008101

Esc-C Add-OK

Admin Setup

008101No-C Yes-OK

Admin Setup

Esc-C Add-OK

Admin Setup

ID 000000

MENU User

SetupUSB Flash

User ▼

Admin SetupAdmin Clear

[M]

Select [User]

[OK]

Selelct [Admin Setup]

[OK] [OK] [OK] [OK]

Setup successful

IN

09 : 00 26

10-11-17 WED

Input Admin ID

[OK]

Enroll FP

Place Finger #2

Enroll FP

Place Finger #1

Enroll fingerprint

Enroll FP

008101-1 Sav-OK

Press [OK] to save

Enroll1/2

Password/CardEsc-C Set-OK

Select [FP]

[OK] FP

Enroll Fingerprint : Place finger on the sensor twice to enroll fingerprints.

Enroll Password: Password length: 0-999999.

Enroll PWD

PWD ID ******Esc-C Set-OK

Input password

Enroll PWD

008101-PCancel-C Sav-OK

Press [OK] to save

[OK] [OK] [OK] [OK]

Enroll PWD

PWD ID ******Confm ******

Input password again

Enroll

FP 1/2

Password /Card

Esc-C Set-OK

Select [Password]

Enroll Card:

Enroll Card

Swipe card!

Enroll Card

008101-CCancel-C Sav-OK

Enroll

FP 1/2

Password/ Card

Esc-C Set-OK

[OK]

Select [Card] Swipe the card Press [OK] to save

[OK]

Enroll

ID 008101 Esc-C Set-OK

IN

09 : 00 26

10-11-17 WED

MENUUser

SetupUSB Flash

User ▼

EnrollDeleteVerify Mode

[M]

Select [User]

[OK]

Select [Enroll]

[OK]

Input user ID

Enroll User: Each user can register two fingerprints, one password and one card.

Explanation

1

Item

Factory default setting

1-99999999 Device ID of the unit which is required in softwarecommunication

Dev ID:

Tips: WorkCode indicates the work type,easily distinguishes which attendance recordis related to which work type.

Explanation

Max 999999 Min 0

Item

Factory default setting

0-999999 Valid scope for the Workcode

WorkCode:

Item Explanation

Factory default setting

Any

RF+PW

RF+FP

PW+FP

Fingerprint only, Card only or ID+Password only

It requires both Card and Password verificationtogether

It requires both Card and Fingerprint verification togetherIt requires both Password and Fingerprint verificationtogether

Enter the user ID first, then verify the fingerprint

Any

ID+FP

Verify Mode:

TCP/IP

Power

G-LED R-LED

D0 D1

W0

12V OUT

DOOR OPEN

W1

12V IN

COM NO

NC GND

GND

U Disk

Mini USB

Flas

h M

emor

y

USB

TCP/IP

3.FN key

(The function with mark in the menu is for the specific model unit. Please follow as actual product’s menu. )

(ID number range:0-999999)

Tips: Group setup is used for managing the access control privileges. Each group can contain 4 time zones.The default setting: G01.

Explanation

G01

Item

Factory default setting

G00

G01

G02-16

The user in Group00 can not open the door

The user in Group01 can open the door anytime

It is according to the Group & Time zone setting which can be set through the software

Group Setup:

V1.2

M→[Setup]→[OK]→[System]→[OK]→[Dev ID]→[OK]→Input the device’s ID→[OK]→[C]→[OK].

M→ [Setup]→[OK]→[System]→[OK]→[WorkCode Scope]→[OK]→Input Max→[OK]→Input Min→[OK] →[C]→[OK].

M→[User]→[OK]→[Verify Mode]→[OK]→[OK]→Input employee ID→[OK]→Use [IN/ ]/[OUT/ ] to select ‘ANY/RF+FP/PW+FP/RF+PW/ID+FP’→[OK]→[OK].

ExplanationItem Factory default setting

Server Mode

192.168.0.218

255.255.255.0

192.168.0.1

192.168.0.7

5010

Mode

IP Address

Subnet Mask

MAC Address

Gateway IP

Server IP

Server Port

Net: M→ [Setup]→[OK]→[System]→[OK]→[Net]→[OK]→to select [Mode/IP Address/Subnet Mask/MAC Address/Gateway IP/Server IP/Server Port]→[OK]→Modify parameters→[C]→[OK].

M→[User]→[OK]→[Group Setup]→[OK]→[OK]→Input employee ID→[OK]→Input the group ID→[OK]→[OK].

Explanation

Related Language

Item

Factory default setting

LanguageContains 11 languages:ENG(English), FRCH(French), GERM(German), SPAN(Spanish),PTG(Portuguese), ITA(Italian), BULG(Bulgarian), SLVK(Slovak),HUNG(Hungarian), SLVN(Slovenian), TURK(Turkish)

Language: M→[Setup]→[OK]→[System]→[OK]→[Language]→[OK]→Use [IN/ ]/[OUT/ ] to select ENG/FRCH/GERM/...→[OK]→[C]→[OK].

ExplanationItem

Precision, Volume, Auto off, Auto Update, Image Disp., Log Alert, Re-Verify

Place finger flat on the sensor surface. Sliding, Rolling or Moving finger during the enrollment process.

Do not remove finger during the enrollment process.

Using the tip of your finger.

A Standard USB flash drive with amaximum capacity to 2GB of RAMis required.

TCP/IP Server mode: Common network modeTCP/IP Client mode: Only communicatewith the PC which has static IPSet terminal IP address when communication of TCP/IP, IP address must be a static IP address

Subnet Mask of the LAN

Unique Physical address of the network moudle. This setting can not be modified. Default Gateway of the LAN The IP address of the Sever Machine when using Client Mode TCP/IP communication.It’s the Software Port number used when theread is configured for TCP/IP communication

Image Disp.

The duration of time in which the terminal will ignore repeated attempts for authentication.[No]: Disable the function; Max. value is 250 min.

Re-Verify

Auto update means the previous lower quality fingerprinttemplate will be automatically replaced by the new higher quality one during fingerprint verification.Choose to display the fingerprint image on the screen duringthe verification process. [Yes] - show fingerprint image,[No] - not show fingerprint image

Set the time duration for an idle clock to go into sleep mode. No-[Not Off], 250min-[Max Time].

Set the terminal voice volume.0-[mute], 5-[Max].

Set terminal fingerprint matching precision.0-[Normal],1-[Good], 2-[Exact].Precision

Volume

Auto off

Log Alert

Auto Update

The terminal will alarm when the memory capacity is less than the [Log Alert] value.[No]-Not alarm, Max. value 5,000.

Wiegand Output

Wiegand Input