talmud torah community centre -...
TRANSCRIPT
Client/Project
Project No.
Talmud Torah Schooland Jewish Federation
144104546
Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
TALMUD TORAH COMMUNITY CENTRE
. TALMUD TORAH EXISTING SURVEY PLAN
1. ZONING BYLAW OVERVIEW
2. SITE PLAN
3. MAIN FLOOR PLAN
4. SECOND FLOOR PLAN
5. WEST AND EAST ELEVATIONS
6. NORTH AND SOUTH ELEVATIONS
7. TYPICAL WALL SECTION
8. TALMUD TORAH EXISTING MECHANICAL PLAN
9. RENDERINGS
TALMUD TORAH COMMUNITY CENTRE ADDITION
FEASIBILITY REPORT
-
A01
A02
A03
A04
A05
A06
A07
A08
A09
Client/Project Title
Figure No.Reference SheetProject No.
Date
Talmud Torah Schooland Jewish Federation
TABLE OF CONTENTS
A0144104546
05/2/2018Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
TABLE OF CONTENTS
ZONING BYLAW 12800 (NON-RESIDENTIAL USE CLASSES)
23.) PROFESSIONAL, FINANCIAL AND OFFICE SUPPORT SERVICES 1 PARKING SPACE PER 29.4 SQ.M. OF FLOOR AREA REQUIRED: 429.73 SQ.M. / 29.4 SQ.M. =
15 PARKING STALLS PROVIDED: 15 PARKING STALLS
33.) COMMUNITY RECREATION SERVICES 16 PARKING SPACES FOR ROOM GREATER THAN 93 SQ.M. AND
ADDITIONAL 1 PARKING SPACE PER 4.6 SQ.M. OVER 93 SQ.M. OF FLOOR AREA NOT INCLUDE WASHROOMS, STORAGE AND KITCHEN AREAS
MAIN FLOOR AREA (HALL ONLY) 233 SQ.M. - 93 SQ.M.= 140 SQ.M. / 4.6 SQ.M.= 30 STALLS
WHERE COMMUNITY RECREATION SERVICE FACILITY PARKING AREA IMMIDIATELY ABUTS A PARKING AREA FOR A SCHOOL , A MAXIMUM OF 50% OF THE ADDITIONAL PARKING SPACES MAYBE PROVIDED BY INCLUDING THE ABUTTING SCHOOL PARKING AREA.
16 + 30 = 46 / 2 = 23 STALLS MAY BE SHARED WITH SCHOOL
TOTAL PARKING REQUIREMENTS:COMMUNITY CENTRE: 15 + 16 + 30= 61 STALLS -
23 SHARED STALLS
= 38 STALLS REQUIRED
NEW PARKING STALLS PROVIDED:
38 STALLS REQUIRED
30 STALLS PROVIDED ON SITE(INCLUDES 3 ACCESSIBLE STALLSTABLE 3.8.2.2 ABC)
AND 8 STALLS PROVIDED OFF SITE
- MAIN FLOOR GROSS AREA:7,570 SQ.FT.(703.23 SQ.M.)
- SECOND FLOOR GROSS AREA: 4,626 SQ.FT. (429.73 SQ.M.)
- TOTAL DEVELOPMENT: 12,196 SQ.FT. (1,133 SQ.M.)
COMMUNITY CENTRE:
ADDRESS:6320 - 172 STREET NW EDMONTON AB
LEGAL DESCRIPTION:LOT 17 BLOCK 13 PLAN 9525126
SITE AREA:19, 946.556 SQ.M.
CURRENT ZONE:URBAN SERVICE ZONE (US)
NEIGHBOURHOOD:CALLINGWOOD SOUTH
Client/Project Title
Figure No.Reference SheetProject No.
Date
Talmud Torah Schooland Jewish Federation
ZONING BYLAW
A01144104546
05/2/2018Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
PARKING REQUIREMENTS
AREA
SITE
64 AVENUE NW
172 S
TREE
T NW
PRO
PERT
Y LI
NE
SETBACK(4.5 M)
DROP
OFF
TALMUD TORAH SCHOOL
40,138.6 SQ.FT(3729 SQ.M)
PROPOSED COMMUNITY
CENTRE
12,196 SQ.FT(1,133 SQ.M)
EXISTING BASKETBALL FIELD
EXISTINGPLAYGROUND
EXISTINGPLAYGROUND
GARBAGE
EXISTINGPLAYGROUND
AT GRADE LOADING
EXISTINGTRANSFORMER
TO BE RELOCATED
DROP OFF
EXISTING PARKINGSTALLS: 28
NEW PARKINGSTALLS: 4
NEW PARKINGSTALLS: 26
PROPOSED NEWTRANSFORMER
LOCATION
CANOPY ABOVE
PATIO / OUTDOOR AMENITY
EXISTING PRIMARY SERVICE LINE TO BE
DECOMMISSIONED
EXISTING PRIMARYSERVICE LINECONNECTOR
FROM 64 AVE.
EXISTING GAS
EXISTING WATER
EXISTING POWER
8 OFF SITE STALLS
NEW ACCESS
GREASY
NEW SECONDARYSERVICE LINE
LANDSCAPE
ADDRESS:6320 - 172 STREET NW EDMONTON AB
LEGAL DESCRIPTION:LOT 17 BLOCK 13 PLAN 9525126
SITE AREA:19, 946.556 SQ.M.
CURRENT ZONE:URBAN SERVICE ZONE (US)
NEIGHBOURHOOD:CALLINGWOOD SOUTH
EXISTING LANDSCAPE
AT GRADE LOADING
EXISTING SIDEWALK
NEW PATIO / OUTDOOR AMENITY
EXISTING PARKING AREA
PROPERTY LINE
SETBACK
EXISTING PRIMARY POWER LINE
NEW SECONDARY POWER LINE ENCASED IN CONCRETED
EXISTING GAS
EXISTING WATER
Client/Project Title
Figure No.Reference SheetProject No.
Date
Talmud Torah Schooland Jewish Federation
SITE PLAN
A02144104546
05/02/2018Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
1 : 600A021 SITE PLAN.
SITESITE PLAN LEGEND
N
EXISTING BUILDING
NEW CONSTRUCTION
AT GRADE LOADING AREA
PROPERTY LINE
SETBACK
LINE OF CANOPY ABOVE
EXISTING PRIMARY POWER LINE
NEW SECONDARY POWER LINEENCASED IN CONCRETE
4' X 4' REFERENCE GRID
Ex. 1
Ex. E
Ex.H
Ex.3C1 C9
A2
ELEC. EXISTING POWER
JAN.
17.00 m²182.94
STORAGE19.86 m²213.76
WASHROOM
22.65 m²243.77
WASHROOM
PROP
ERTY
LINE
OPEN TO ABOVE
EXISTINGMECHANICAL
SETBACK
43' - 8"13314.68
22' - 4 1/2"6820.00
12' - 3"3731.00
21' -
5"
6523
.30
93' -
5 1/2"
2848
2.60
24' -
2 1/2"
7375
.00
5.56 m²59.90
ELEC.
16.38 m²176.26
STAIR 2
1 A05
1A06
2A06
2 A05
34.43 m²370.63
MEAT
21.90 m²235.76
SERVERY
OPTION 1170 SEATING
AT GRADELOADING
GARBAGERELOCATED
EXISTING GAS
EXISTING WATER
4.13 m²44.45
LIFT
7.26 m²78.10
W. IN FREEZER
10.03 m²107.95
W. IN COOLER
31.41 m²338.10
RECEIVING
16.51 m²177.69
STAIR 1
36.47 m²392.61
YOUTH LOUNGE
7.27 m²78.24
VEST.
3.21 m²34.60
JAN.
48.64 m²523.57
CORRIDOR
CANOPY ABOVE
O.H. DOOR
O.H. DOOR
PATIO / OUTDOOR AMMENITY
EXISTINGTRANSFORMER
TO BE REMOVED
PROPOSED NEW TRANSFORMER
LOCATION
SECONDARYSERVICE LINE
PRIMARYSERVICE LINECONNECTOR
FROM 64 AVE.
EXISTING SCHOOL
SETB
ACK
LINE OFBUILDING
ABOVE
A1
139'
- 0 1/
2"
4238
0.90
78' - 3 1/2"23865.68
32.46 m²349.45
DAIRY
17.00 m²182.94
STORAGE
DUTCHDOOR
STUDENTSIGN IN
6.90 m²74.32
WASHROOM
233.00 m²2508.00
COMMUNITYHALL
PROJECTOR
CHANGETABLE
47.05 m²506.49
CORRIDOR
- MAIN FLOOR GROSS AREA:7,570 SQ.FT.(703.23 SQ.M.)
- SECOND FLOOR GROSS AREA: 4,626 SQ.FT. (429.73 SQ.M.)
- TOTAL DEVELOPMENT: 12,196 SQ.FT. (1,133 SQ.M.)
COMMUNITY CENTRE: - GROSS AREA IS CALCULATED FROM THE FINISH FACE OF THE EXTERIOR WALLS & CENTERLINE OF THE DEMISING WALLS.
- COMMUNITY HALL CAPACITY OPTION 1 WITH THE ROUND TABLES 170 SEATS
- COMMUNITY HALL CAPACITY OPTION 2 WITH THE RECTANGULAR TABLES 320 SEATS
- COMMUNITY HALL CAPACITY OPTION 3 CHAIRS ONLY 325 SEATS
OPTION 2320 SEATING
OPTION 3325 SEATS
Client/Project Title
Figure No.Reference SheetProject No.
Date
Talmud Torah Schooland Jewish Federation
MAIN FLOOR PLAN
A03144104546
05/2/2018Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
LEGEND
1 : 250A031 MAIN FLOOR PLAN
AREA NOTES
N
OPTION 2 - RECTANGLE TABLE LAYOUT OPTION 3 - SINGLE CHAIR LAYOUT
Ex. 1
Ex.H
Ex.3C1
Ex. J
C9
A2
5.56 m²59.90
ELEC.
9.27 m²99.77
JNF
9.27 m²99.77
CJPAC
9.09 m²97.81
CAMP BB
16.38 m²176.26
STAIR
16.84 m²181.21
W.C.
12.71 m²136.77
W.C.
CANOPY BELOW
OPEN BELOW
7.19 m²77.37
STORAGE
EXISTING ROOF BELOW
27.38 m²294.70
STAFF
50.62 m²544.88
OPEN WORKSTATIONS
66' - 0 1/2"20134.68
12' - 3"3731.00
21' -
5"
6523
.30
87' -
0"
2651
7.60
30' -
7 1/2"
9340
.00
1 A05
1A06
2A06
2 A05
A119.19 m²206.60
STAIR 1
11.29 m²121.51
STORAGE /OFFICE
6.92 m²74.52
STORAGE
42.02 m²452.31
BOARDROOM
41.83 m²450.25
CORRIDOR
139'
- 0 1/
2"
4238
0.90
43' - 6"13256.58
34' - 7 1/2"10551.00
4.63 m²49.87
JAN.
10.78 m²116.06
CFO OFFICE
13.53 m²145.68
CEO OFFICE
26.37 m²283.86
WAITING ROOM
12.82 m²138.03
JASENA
9.27 m²99.77
OFFICE
- MAIN FLOOR GROSS AREA:7,570 SQ.FT.(703.23 SQ.M.)
- SECOND FLOOR GROSS AREA: 4,626 SQ.FT. (429.73 SQ.M.)
- TOTAL DEVELOPMENT: 12,196 SQ.FT. (1,133 SQ.M.)
COMMUNITY CENTRE:
Client/Project Title
Figure No.Reference SheetProject No.
Date
Talmud Torah Schooland Jewish Federation
SECOND FLOOR PLAN
A04144104546
05/2/2018Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
1 : 250A041 SECOND FLOOR PLAN
AREA
N
MAIN FLOOR
0.00
Ex. E Ex.HEx. J
T.O. PARAPET
9100.00
U/S OF ROOF
8620.00
T.O. SECOND FLOOR
4400.00
A2A1
21' - 5"6523.30
87' - 0"26517.60
6' - 5 1/2"1965.00
24' - 2 1/2"7375.00
NEW GARBAGEENCLOSURE
PROPOSED LOCATION FOR NEW TRANSFORMER
EXISTING TRANSFORMERTO BE RELOCATED
7
324 7
8
28
11
1
12
EXISTING SCHOOL
1
5 37
6
6 1 5
MAIN FLOOR
0.00
Ex. EEx.H Ex. J
T.O. PARAPET
9100.00
U/S OF ROOF
8620.00
T.O. SECOND FLOOR
4400.00
A2 A1
24' - 2 1/2"7375.00
6' - 5 1/2"1965.00
87' - 0"26517.60
21' - 5"6523.30
PROPOSEDLOCATION FORNEW TRANSFORMER
NEW GARBAGEENCLOSURE
3
3 7 11
5
EXISTING SCHOOL
6
761
8
8
DROP OFF 1415
6 2
1
15
Client/Project Title
Figure No.Reference SheetProject No.
Date
Talmud Torah Schooland Jewish Federation
WEST AND SOUTHELEVATIONS
A05144104546
05/2/2018Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
1 : 200A051 West Elevation
1 : 200A052 East Elevation
MATERIAL LEGEND
MARK Description1 PREFINISHED METAL CLADDING - COLOUR 12 ALUMINUM COMPOSITE PANEL3 SPANDREL PANEL4 SMOOTH FACE MASONRY VENEER5 PREFINISHED CAP FLASHING6 PREFINISHED ALUMINUM CURTAIN WALL SYSTEM7 DOUBLE GLAZING CLEAR VISION8 PREFINISHED METAL CLADDING - COLOUR 29 INSULATED METAL DOOR - PAINTED10 OVERHEAD DOOR - PAINTED11 METAL CHANNEL WITH BUILDING SIGNAGE12 CANOPY BEYOND13 PREFINISHED ALUMINUM LAP SIDING AT SOFFIT SPACE14 WOOD COLUMN15 POLYCARBONATE OVERHEAD DOOR INTEGRATED INTO GLAZING FRAME
MAIN FLOOR
0.00
Ex. 1Ex.3Ex.4Ex.5 C1
T.O. PARAPET
9100.00
U/S OF ROOF
8620.00
T.O. SECOND FLOOR
4400.00
C5C9
PRO
PERT
Y LIN
E
23' - 5 1/2"7156.00
24' - 9"7550.00
12' - 3"3731.00
22' - 4 1/2"6820.00
5' - 7 1/2"1714.40
38' - 0 1/2"11600.28
PROPOSED LOCATION FORNEW TRANSFORMER
876 2 103
EXISTING SCHOOL
1
1
1
14
7
786
NEW GARBAGEENCLOSURE
1
4
MAIN FLOOR
0.00
Ex. 1 Ex.3 Ex.4 Ex.5C1
T.O. PARAPET
9100.00
U/S OF ROOF
8620.00
T.O. SECOND FLOOR
4400.00
C5 C9
23' - 5 1/2"7156.00
24' - 9"7550.00
12' - 3"3731.00
22' - 4 1/2"6820.00
5' - 7 1/2"1714.40
38' - 0 1/2"11600.28
PRO
PERT
Y LIN
E
PROPOSED LOCATIONFOR NEW TRANSFORMER
273
7
1
2
EXISTING SCHOOL
1
14
1
6
1
46
5
9
BEYOND
Client/Project Title
Figure No.Reference SheetProject No.
Date
Talmud Torah Schooland Jewish Federation
NORTH AND SOUTHELEVATIONS
A06144104546
05/2/2018Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
1 : 200A061 North Elevation
1 : 200A062 South Elevation
MATERIAL LEGEND
MARK Description1 PREFINISHED METAL CLADDING - COLOUR 12 ALUMINUM COMPOSITE PANEL3 SPANDREL PANEL4 SMOOTH FACE MASONRY VENEER5 PREFINISHED CAP FLASHING6 PREFINISHED ALUMINUM CURTAIN WALL SYSTEM7 DOUBLE GLAZING CLEAR VISION8 PREFINISHED METAL CLADDING - COLOUR 29 INSULATED METAL DOOR - PAINTED10 OVERHEAD DOOR - PAINTED11 METAL CHANNEL WITH BUILDING SIGNAGE12 CANOPY BEYOND13 PREFINISHED ALUMINUM LAP SIDING AT SOFFIT SPACE14 WOOD COLUMN15 POLYCARBONATE OVERHEAD DOOR INTEGRATED INTO GLAZING FRAME
MAIN FLOOR100000
T.O. SLAB -SECOND FLOOR
104400
2'
P.3
W3
W1
W3
R1
F2
960
2240
1200
960
2240
PREFINISHED METAL CAP FLASHING
SBS MEMBRANE ON
SLOPED WOOD BLOCKING
DEFLECTION TRACK TO U/S BEAM - TYP
PROVIDE STEEL STUD
FRAMING AS REQUIRED PRE-FINISHED METAL DRIP
FLASHING - LAP AIR/VAPOUR
MEMBRANE OVER FLASHING - TYP
WOOD BLOCKING AS
REQUIRED
PRE-FINISHED METAL SILL
FLASHING - TYP
PROVIDE STEEL STUD
FRAMING AS REQUIRED
DEFLECTION TRACK TO U/S BEAM - TYP
PRE-FINISHED METAL SILL
FLASHING - TYP
PREFINISHED METAL PANEL (ACM)
C/W SUBGIRT SYSTEM (TYP.)
F1
CEILING TYPE. T.B.D.
108620
U/S OF ROOF
109100
T.O. PARAPET
GLASS - CLEAR
GLASS - CLEAR
CEILING TYPE. T.B.D.
2235
1500
EXTERIOR WALL TYPES:
W1 - BRICK VENEER ON STEEL STUDS
- BRICK VENEER (RUNNING BOND)
- 25mm AIR SPACE
- R20 MIN. 125mm SEMI-RIGID INSULATION c/w 150mm THERMALLY BROKEN
HORIZONTAL AND VERTICAL CLIP SYSTEM.
- SELF ADHERED AIR/VAPOUR BARRIER
- 13mm EXTERIOR GRADE SHEATHING
- 152mm ENGINEERED STEEL STUDS
- 16mm GYPSUM BOARD
CONSTRUCTION ASSEMBLIES:
W3 - ACP ON STEEL STUDS OR PREFINISHED METAL PANEL
- PREFINISHED ALUMINUM COMPOSITE PANEL
c/w CLIP SYSTEM BY MANUFACTURER
- 25mm AIR SPACE
- R20 MIN. 125mm SEMI-RIGID INSULATION c/w 150mm THERMALLY BROKEN
HORIZONTAL AND VERTICAL CLIP SYSTEM.
- SELF ADHERED AIR/VAPOUR BARRIER
- 13mm EXTERIOR GRADE SHEATHING
- 152mm ENGINEERED STEEL STUDS
- 16mm GYPSUM BOARD
PARAPET TYPES:
P.3 - ACP ON STEEL STUDS
- PREFINISHED ALUMINUM COMPOSITE PANEL
c/w CLIP SYSTEM BY MANUFACTURER
- 25mm AIR SPACE
- R20 MIN. 125mm SEMI-RIGID INSULATION c/w 150mm THERMALLY BROKEN
HORIZONTAL AND VERTICAL CLIP SYSTEM.
- SELF ADHERED AIR/VAPOUR BARRIER
- 13mm EXTERIOR GRADE SHTG.
- 152mm ENGINEERED STEEL STUDS
- 13mm PLYWOOD SHTG.
- ROOF MEMBRANE
ROOF TYPES:
R1 - TYPICAL ROOF CONSTRUCTION - MIN OVERALL RSI VALUE 6.1
- SBS ROOF MEMBRANE
- SBS ROOF MEMBRANE SUPPORT PANEL
- 16mm FIBREBOARD
- MIN. 120mm ROOF INSULATION
- SELF ADHERED AIR/VAPOUR BARRIER
- 13mm EXTERIOR GRADE GYPSUM BOARD
- STEEL ROOF DECK
- STEEL STRUCTURE
FLOOR TYPES:
F2 - TYPICAL FLOOR CONSTRUCTION
- CONC. COVER
- 38mm STEEL DECK
- STEEL STRUCTURE
- ULC RATED SPRAY-ON FIREPROOFING TO DECK AND SUPPORTING STRUCTURE, 1
HR. FIRE-RESISTANCE RATING AS REQUIRED BY ALBERTA BUILDING CODE
F1 - TYPICAL SLAB CONSTRUCTION
- FLOOR FINISH AS SPECIFIED
- 200mm STRUCTURAL CONC. SLAB
- 100mm VOID FORM
- 15mil POLY VAPOUR BARRIER
- 100mm RADON/METHANE GUARD INSULATION
- 50mm LEVELING SAND
- UNDISTURBED SOIL
1 : 50A08
1 WALL SECTION
Client/Project Title
Figure No.Reference SheetProject No.
Date
Talmud Torah Schooland Jewish Federation
TYPICAL WALL SECTION
A08144104546 -
05/2/2018Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
Client/Project Title
Figure No.Reference SheetProject No.
Date
Talmud Torah Schooland Jewish Federation
RENDERINGS
A09144104546
05/02/18Stantec Architecture Ltd.10160 112 StreetEdmonton, AB T5K 2L6Tel: (780) 917-7000 • www.stantec.com
Talmud TorahCommunity Centre
NORTH APPROACH
NORTH WEST VIEWSOUTH WEST VIEW