table of contents - okcc. · pdf filetable of contents page picture index ... sapphire orifice...

90
P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331 © O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] website www.okcc.com 2 Table of Contents Page Picture Index ...................................................................................................................... 3 "Where to Find It" Sapphire Orifice Assemblies ......................................................................................... 4-5 Metal Orifice Assemblies - Barb Connections .............................................................. 6-7 Metal Orifice Assemblies - NPT Connections .............................................................. 8-9 Metal Orifice Assemblies - Inserts ............................................................................ 10-11 Metal Orifice Assemblies - Compression Fittings .......................................................... 11 Metal Orifice Assemblies - Threaded Inserts ............................................................ 12-13 Metal Orifice Assemblies - Miscellaneous ................................................................ 14-15 Orifice Air Flow Charts ............................................................................................. 16-18 Precision Micro-Orifices ® .0003" to .005" Diameter ............................................. 19-21 Screened Orifices - Integral Wire Screens ................................................................ 22-27 Restriction Orifice Unions ............................................................................................... 27 Miniature In-Line Screens ......................................................................................... 28-29 Breathers .......................................................................................................................... 30 Pressure Snubbers ............................................................................................................ 31 Orifice Kits ................................................................................................................ 32-33 Custom Orifice Assemblies ............................................................................................. 33 Engineering Information - Orifice Flow Fundamentals of Flow Measurement ....................................................................... 34 Extending Orifice Flow Data ................................................................................... 35 Technical Considerations ......................................................................................... 36 Calibrated Orifices ................................................................................................... 37 Choked Flow of Gases ............................................................................................. 38 Water Flow Products Fixed Flow Rate Orifices ......................................................................................... 39 Water Totalizer with Remote Readout ..................................................................... 40 Accessories Tubing & Fittings ..................................................................................................... 41 Flow Meters ............................................................................................................. 42 Regulators, Filters, Low Pressure Switches ............................................................. 43 Check Valve Products Miniature Ball Check Valves ............................................................................. 44-46 Miniature Fixed Flow Controls .......................................................................... 44-46 Miniature Checked Orifices ..................................................................................... 47 Disk Type Check Valves .................................................................................... 48-50 Disk Type Fixed Flow Controls ......................................................................... 48-50 About O'Keefe Controls Co. ............................................................................................ 51 ® Registered Trademark of O'Keefe Controls Co. 1/1/01 Rev. 2 See Catalog and Product Updates on our Website www.okcc.com ® ®

Upload: vunhu

Post on 27-Mar-2018

250 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

2Table of Contents

PagePicture Index ......................................................................................................................3

"Where to Find It"

Sapphire Orifice Assemblies ......................................................................................... 4-5

Metal Orifice Assemblies - Barb Connections .............................................................. 6-7

Metal Orifice Assemblies - NPT Connections .............................................................. 8-9

Metal Orifice Assemblies - Inserts ............................................................................ 10-11

Metal Orifice Assemblies - Compression Fittings ..........................................................11

Metal Orifice Assemblies - Threaded Inserts ............................................................ 12-13

Metal Orifice Assemblies - Miscellaneous................................................................ 14-15

Orifice Air Flow Charts ............................................................................................. 16-18

Precision Micro-Orifices® .0003" to .005" Diameter ............................................. 19-21

Screened Orifices - Integral Wire Screens ................................................................ 22-27

Restriction Orifice Unions ...............................................................................................27

Miniature In-Line Screens ......................................................................................... 28-29

Breathers ..........................................................................................................................30

Pressure Snubbers ............................................................................................................31

Orifice Kits ................................................................................................................ 32-33

Custom Orifice Assemblies .............................................................................................33

Engineering Information - Orifice Flow

Fundamentals of Flow Measurement .......................................................................34

Extending Orifice Flow Data ...................................................................................35

Technical Considerations .........................................................................................36

Calibrated Orifices ...................................................................................................37

Choked Flow of Gases .............................................................................................38

Water Flow Products

Fixed Flow Rate Orifices .........................................................................................39

Water Totalizer with Remote Readout .....................................................................40

Accessories

Tubing & Fittings .....................................................................................................41

Flow Meters .............................................................................................................42

Regulators, Filters, Low Pressure Switches .............................................................43

Check Valve Products

Miniature Ball Check Valves ............................................................................. 44-46

Miniature Fixed Flow Controls .......................................................................... 44-46

Miniature Checked Orifices .....................................................................................47

Disk Type Check Valves .................................................................................... 48-50

Disk Type Fixed Flow Controls ......................................................................... 48-50

About O'Keefe Controls Co.............................................................................................51

® Registered Trademark of O'Keefe Controls Co.

1/1/01 Rev. 2

See Catalog and Product Updates on our Websitewww.okcc.com

®®

Page 2: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

3

TYPE APLASTIC INSERT

Press fits into .125"/.126" Bore

TYPE LADAPTER

10-32 Thread by 1/16" Barb

"WHERE TO FIND IT"

Picture Index

Sapphire Orifice Assemblies – Pages 4-5

Metal NPT Orifices – Pages 8-9, 19-21

Orifice Kits – Pages 32-33

Metal Barb Orifices – Pages 6-7, 19-21

TYPE FPLASTIC INSERT

Press fits into .132"/.133" Bore

TYPE PBLEED PLUG10-32 Thread

TYPE JHEX NIPPLE

1/8" NPT

TYPE SDUAL BARB

For 1/16" ID Tubing

TYPE T or WDUAL BARB1/16" or 1/8"

TYPE M or NADAPTER

10-32 by 1/16" or 1/8" Barb

TYPE QBLEED PLUG10-32 Thread

Type BT or BWADAPTER

1/8" NPT by 1/16" or 1/8" Barb

Orifice Inserts - Press Fit – Page 10

Threaded Inserts – Pages 12-13Inch or Metric

Pressure Snubbers – Page 31

Miscellaneous Metal Orifices – Pages 14-15

Orifices with Integral Screens – Pages 22-27

Accessories – Pages 41-43

WaterTotalizer

with RemoteReadout

TYPE AMFits into .126"/.127"

Dia. Hole

TYPE IAFits into .256"/.257"

Dia. Hole

TYPE IBFits into .0930"/.0940"

Dia. Hole

TYPE UFits into .279"/.280"

Dia. Hole

TYPE Z, ZMSet Screw Style

TYPE DP, GP or HP1/8", 1/4" or 1/2" NPT

TYPE BSHEX NIPPLE

1/8" NPT

TYPE QSBLEED PLUG10-32 Thread

TYPE BMMSBLEED PLUG

1/8" NPT

TYPE USDUAL SCREEN INSERT

Fits into .2795"/.2805" Dia. Hole

TYPE K4TUBE CONNECTION

1/4" OD Tube

TYPE R4CIRCULAR DISK

.47" Diameter

TYPE BFSSAE 45°

FLARE FITTING

Fixed Flow Controls – Pages 44-50

Screen Products – Pages 28-29

TYPE SSA, SSB or SSCBOUND SCREEN

.211" .254" or .312" Diameter

TYPE FFSSCREEN FITTING

10-32 Thread

TYPE BMB or EMBBREATHER

1/8" or 1/4" NPT

TYPE DSO or GSOSCREEN FITTING

1/8" or 1/4" NPT Adapter

TYPE QSBBREATHER10-32 Thread

Orifice kits provide a widerange of orifice sizes andflow rate. Kits are availablefor metal and sapphireorifices as well as forMicro-Orifices®.

TYPE B or EHEX NIPPLE

1/8" or 1/4" NPT

TYPE D, G or HADAPTER

1/8", 1/4" or 1/2" NPT

TYPE BM or EMBLEED PLUG

1/8" or 1/4" NPT

TYPE BH or EHBLEED PLUG

1/8" or 1/4" NPT

Low PressureAir Switches

PrecisionPressure

Regulators Flowmeters Fittings

® Registered Trademark of O'Keefe Controls Co.

Page 40

Ball Check Valves – Pages 44-46

TYPE BLC or ELC1/8" or 1/4"NPT

TYPE FFLC10-32 Thread

TYPE BLF or ELF1/8" or 1/4"NPT

TYPE FFLF10-32 Thread

Disk Check Valves – Pages 48-50

TYPE DOC or GOC1/8" or 1/4"NPT

TYPE Y2C, Y4C or Y6C1/8", 1/4" or 3/8" NPT

Check ValveOrifice

Checked Orifices – Page 47

TYPE BILFC or EIJLC1/8" or 1/4"NPT

TYPE FIFLCS10-32 Thread

Check Valve OrificeScreen

Page 3: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

4Sapphire Orifice Assemblies

DescriptionThe restrictors incorporate a precision synthetic sapphire orificewhich is fitted within a main body. The sapphire orifice is a stable,accurate flow restrictor. Standard sizes range from .0012" to.0252" orifice diameter in 32 increments.

Applications• Precision Flow Control - Gases or Liquids• Accurate Timing in Pneumatic or Hydraulic Circuits• Pressure Dividing Circuits and Pneumatic Resistance Bridges• Impedance Matching

Advantages• Repeatable Orifice Size and Shape• Economical Precision Orifice• Low Clog Probability

Options• Electroless nickel plating is available on Type S and

Type L. Add suffix EN.• Plating is for external appearance only.

KitsSee page 33 for kit selection.

General SpecificationsMaximum Operating Pressure – 100 psigFlow Direction – Preferred direction shown at right.Not recommended for reverse flow.Flow – See flow chart for air on page 18.Orifice Diameters – .0012" to .0252"Orifice Diameter Accuracy – ±.0003"Cv Range – .00003 to .013 See page 18.Fluid Media – Air, Water, Gases and Liquids compatible withmaterials of construction.Dimensions – See drawings on page 5.

Size Orifice DiameterNumber mm In.

3 .03 .00124 .04 .00165 .05 .00206 .06 .00247 .07 .00288 .08 .00319 .09 .003510 .10 .003911 .11 .004312 .12 .004713 .13 .005114 .14 .005515 .15 .005916 .16 .006317 .17 .006718 .18 .007120 .20 .007922 .22 .008724 .24 .009426 .26 .010228 .28 .011030 .30 .011832 .32 .012634 .34 .013436 .36 .014240 .40 .015744 .44 .017348 .48 .018952 .52 .020554 .54 .021358 .58 .022864 .64 .0252

Sapphire Sizes Available

The restrictors should be installed with flow in the direction shown above. The flowdata provided in this catalog is measured for the flow direction shown above.

.0012" to .0252" DIA.

Construction

Part NumbersThe complete part number for an orifice assembly includes Type,Size Number, Body Material and Options.

EXAMPLESize Number Body Part

Type (Orifice Dia.) Material Options Number

A 3 (.0012") Nylon — A-3-NY

S 5 (.0020") Brass — S-5-BR

S 5 (.0020") Brass EN S-5-BR-EN

J 10 (.0039") Brass — J-10-BR

J 10 (.0039") SS — J-10-SS

Type F Type A

Type S Type J

Type L Type P

Type SF Type BTF, BWF

LargeBore End

SmallBore End

LargeBore End

SmallBore End

LargeBore End

SmallBore End Large

Bore EndSmall

Bore End

LargeBore End

SmallBore End

LargeBore End

SmallBore End

Page 4: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

5Sapphire Orifice Assemblies

SpecificationsDimensionsPLASTIC INSERT

Body – NylonOrifice – Synthetic SapphirePress fits into bore – .125"/.126"Standard Orifice Sizes – .0012" to .0252" Dia.

PLASTIC INSERTBody – NylonOrifice – Synthetic SapphirePress fits into bore – .132"/.133"Fits into tubing – 1/8" ID Flexible PlasticStandard Orifice Sizes – .0012" to .0252" Dia.

HEX NIPPLEBody – Brass or 303 SSInsert – NylonOrifice – Synthetic SapphireThreads – 1/8" NPTStandard Orifice Sizes – .0012" to .0252" Dia.

ADAPTERBody – Brass Seal – VitonOrifice – Synthetic SapphireThread – 10-32 UNF, 1/8" NPTBarb – For 1/16" or 1/8" ID TubingOption – Electroless nickel plating on brass (Type L)Standard Orifice Sizes – .0012" to .0252" Dia.

BLEED PLUGBody – Brass Seal – VitonOrifice – Synthetic SapphireThread – 10-32 UNFStandard Orifice Sizes – .0012" to .0252" Dia.

DUAL BARBBody – BrassOrifice – Synthetic SapphireBarb – For 1/16" or 3/32" ID TubingOption – Electroless nickel plating on brassStandard Orifice Sizes – .0012" to .0252" Dia.

DUAL BARBBody – BrassOrifice – Synthetic SapphireBarb – For 1/16" ID TubingStandard Orifice Sizes – .0012" to .0252" Dia.

Type A

Type F

Type J

Type L10-32 x 1/16" barb

Type BTF1/8" NPT x 1/16" barb

Type BWF1/8" NPT x 1/8" barb

Type P

Type S

Type SF Barb for 1/16" ID TubingBoth Ends

3/16" HEX

9/16"

Press Fit Into Bore.125"/.126" Dia.

.128"/.129" Dia..194"/.196" Dia.

.110" .196"

.134"/.137" Dia.

.306"

1/4" HEX

10-32 Straight ThreadSeal

No ConnectionThis End

Barb for 1/16" or 3/32"ID Tubing Both Ends

3/16" HEX9/16"

1/8" NPT - both ends

7/16" HEX

.970"

9/32"

.0012" to .0252" DIA.

ThreadSeal

HEXW

Barb for Tubing

Type W HEXL .53" 1/4"BTF .86" 7/16"BWF .94" 7/16"

Page 5: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Orifice SizeSize Dia. Number

Number In. Range

4 .00395 .00516 .0059 Type T7 .0071 Brass 4-358 .0079 303 SS 4-359 .009110 .0102 Type W11 .0110 Brass 4-6312 .0122 303 SS 4-6313 .013014 .0142 Type M15 .0150 Brass 4-3516 .016 303 SS 4-3517 .01718 .018 Type N19 .019 Brass 4-6320 .020 303 SS 4-6321 .02122 .022 Type Q23 .023 Brass 4-3524 .02425 .025 Type BT26 .026 Brass 4-3527 .027 303 SS 4-3528 .02829 .029 Type BW31 .031 Brass 4-6332 .032 303 SS 4-6333 .03335 .035 Type QX37 .037 Brass 4-3538 .038 303 SS 4-3539 .03940 .040 Type FM41 .041 Brass 4-6342 .042 303 SS 4-6343 .04347 .047 Type FF52 .052 Brass 4-6355 .055 303 SS 4-6360 .06063 .063

The complete part number for an orifice assembly is composed of Type,Size Number, Body Material and Options.

EXAMPLESize Body Part

Type Number Material Options Number

T 4 (.004") Brass – T-4-BR

BW 16 (.016") SS – BW-16-SS

M 24 (.024") Brass – M-24-BR

DescriptionOne-piece construction of solid metal isemployed. Orifices are accurately machined,thoroughly cleaned, and flow tested to ex-acting standards. Sizes range from .004" to.063" orifice diameter. Special sizes can bemade to order.

Applications• Precision Flow Control -

Gases or Liquids• Speed Controls -

Cylinders and Actuators• Accurate Timing in Pneumatic or

Hydraulic Circuits• Flow Restriction• Accurate Throttling• Snubbers - Gages and Instruments

Advantages• High Pressure Capability• Bi-directional Flow Compatibility• Economical Precision Orifice• Repeatable Orifice Size and Shape• Predictable Flow Rate

Flow DirectionMetal Orifice Assemblies can be used forflow in either direction. The data on pages16 and 17 is for a flow direction as shown inthe right column on this page.

KitsSee page 32 for kit selection.

General SpecificationsMaximum Operating Pressure – 100 psigFlow – See flow chart for air onpages 16 and 17.Orifice Diameters – .004" to .063"Orifice Diameter Accuracy – ±.0003"Cv Range – .00035 to .088See pages 16 and 17.Fluid Media – Air, Water, Gases andLiquids compatible with materials ofconstruction.Dimensions – See drawings on page 7.

ConstructionBARB CONNECTIONS

Part Numbers

Type T or W

Type M or N

Type Q

Type BT or BW

Type QX

Type FM

Type FF

Metal Orifice Assemblies6

Page 6: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

7

BARB CONNECTIONS

Metal Orifice Assemblies

SpecificationsDimensions

DUAL BARBBody and Orifice – Brass or SSStandard Orifice Sizes –

Type T – .004" to .035" Dia.Type W – .004" to .063" Dia

ADAPTERBody and Orifice – Brass or SSThread – 10-32 UNFThread Seal – VitonStandard Orifice Sizes –

Type M – .004" to .035" Dia.Type N – .004" to .063" Dia.

BLEED PLUGBody and Orifice – BrassThread – 10-32 UNFThread Seal – VitonStandard Orifice Sizes – .004" to .035" Dia.

ADAPTERBody and Orifice – Brass or SSThread – 1/8" NPTStandard Orifice Sizes –

Type BT – .004" to .035" Dia.Type BW – .004" to .063" Dia.

BLEED PLUGBody and Orifice – Brass or SSThread – 10-32 UNFThread Seal – VitonStandard Orifice Sizes – .004" to .035" Dia.

ADAPTERBody and Orifice – Brass or SSThread – 10-32 UNFThread Seal – VitonStandard Orifice Sizes – .004" to .063" Dia.

COUPLERBody and Orifice – Brass or SSThreads – 10-32 UNFStandard Orifice Sizes – .004" to .063" Dia.

Type T or W

Barbs fit 1/16" or 1/8" ID Tubing.

Type M or N

Barbs fit 1/16" or 1/8" ID Tubing.

Type Q

Type BT or BW

Barbs fit 1/16" or 1/8" ID Tubing.

Type QX

Type FM

Type FF

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Type Dim. L HEX BarbBT .800" 7/16" 1/16"BW .880" 7/16" 1/8"

Type Dim. L HEX BarbM .530" 1/4" 1/16"N .610" 1/4" 1/8"

1/8" NPT

Barb

HEX

L

Barb For Plastic Tubing

HEX

LType Dim. L HEX Barb

T .625" 3/16" 1/16"W .800" 1/4" 1/8"

Barb forPlastic Tubing

10-32 Straight Thread

L

Seal

HEX

10-32 StraightThread

1/4"HEX

Seal

.280"

10-32 Straight ThreadSeal 1/4" HEX

7-1/2°

.335"

Round

.312" Dia.

.500"

10-32Thread

10-32Thread

10-32 Straight Thread

Seal.440"

5/16" HEX

10-32 Straight Thread

Page 7: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

8

Type B, E or V

Orifice diameter .021" or larger

Orifice diameter .020" or smaller

Type D, G, H or VV

Orifice diameter .021" or larger

Orifice diameter .020" or smaller

Type BM or EM

Type BH or EH

Type BMM

The complete part number for an orifice assembly includes Type, Size Number,Body Material and Options.

EXAMPLESize Body Part

Type Number Material Options Number

B 10 (.010") Brass – B-10-BR

G 15 (.015") Brass – G-15-BR

D 20 (.020") SS – D-20-SS

Applications• Precision Flow Control –

Gases or Liquids• Speed Controls –

Cylinders and Actuators• Accurate Timing in Pneumatic or

Hydraulic Circuits• Flow Restriction• Accurate Throttling• Snubbers - Gages and Instruments• Ultrasonic Sound Sources

Advantages• High Pressure Capability• Bi-directional Flow Compatibility• Economical Precision Orifice• Repeatable Orifice Size and Shape• Predictable Flow Rate

Flow DirectionMetal Orifice Assemblies can be used forflow in either direction. The data on pages16 and 17 is for a flow direction as shown inthe right column on this page.

KitsSee page 32 for kit selection.

General SpecificationsMaximum Operating Pressure –

Brass 2000 psig303 SS 4000 psig

Flow – See flow chart for air on pages 16 and 17.Orifice Diameters – .004" to .125" standard.Consult factory for other sizes.Orifice Diameter Accuracy – ±.0003"Cv Range – .00035 to .37 See pages 16 and 17.Fluid Media – Air, Water, Gases and Liquidscompatible with materials of construction.Dimensions – See drawings on page 9.

Part Numbers

NPT CONNECTIONS Construction

Metal Orifice Assemblies

Orifice SizeSize Dia. Number

Number In. Range4 .00395 .00516 .00597 .00718 .00799 .009110 .010211 .011012 .012213 .013014 .014215 .015016 .01617 .01718 .01819 .01920 .02021 .02122 .02223 .02324 .02425 .02526 .02627 .02728 .02829 .02931 .03132 .03233 .03335 .03537 .03738 .03839 .03940 .04041 .04142 .04243 .04347 .04752 .05255 .05560 .06063 .06367 .06770 .07073 .07376 .07679 .07981 .08186 .08689 .08994 .09496 .096100 .100104 .104109 .109113 .113120 .120125 .125

Type B, E or VBrass 4-125303SS 4-125

Type D, G, H or VV

Brass 4-125303SS 4-125

Type BM or EMBrass 4-125303SS 4-125

Type BH or EHBrass 4-125303SS 4-125

Type BMMBrass 4-125303SS 4-125

DescriptionOne-piece construction of solid metal isemployed. Orifices are accurately machined,thoroughly cleaned, and flow tested to ex-acting standards. Sizes range from .004" to.125" orifice diameter. Special sizes can bemade to order.

Page 8: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

9

NPT CONNECTIONS

Metal Orifice Assemblies

SpecificationsDimensionsHEX NIPPLE

Body and Orifice – Brass or SSThreads – 1/8", 1/4" or 3/8" NPTStandard Orifice Sizes –

Brass – .004" to .125" Dia.303 SS – .004" to .125" Dia.

ADAPTERBody and Orifice – Brass or SSThreads – 1/8", 1/4", 3/8" or 1/2" NPTStandard Orifice Sizes –

Brass – .004" to .125" Dia.303 SS – .004" to .125" Dia.

BLEED PLUGBody and Orifice – Brass or SSThread – 1/8" or 1/4" NPTStandard Orifice Sizes –

Brass – .004" to .125" Dia.303 SS – .004" to .125" Dia.

BLEED PLUGBody and Orifice – Brass or SSThread – 1/8" or 1/4" NPTStandard Orifice Sizes –

Brass – .004" to .125" Dia.303 SS – .004" to .125" Dia.

BLEED PLUGBody and Orifice – Brass or SSThread – 1/8" NPTStandard Orifice Sizes –

Brass – .004" to .125" Dia.303 SS – .004" to .125" Dia.

Type B, E or V

Type D, G, H or VV

Type BM or EM

Type BH or EH

Type BMM

1/8" NPT

.675"

7/16" HEX

Type Dim. L HEX NPTB .97" 7/16" 1/8"E 1.38" 9/16" 1/4"V 1.47" 11/16" 3/8"

Type Dim. L HEX NPTD .88" 9/16" 1/8"G 1.25" 3/4" 1/4"

VV 1.52" 7/8" 3/8"H 1.69" 1-1/16" 1/2"

Type Dim. L HEX NPTBH .30" 3/16" 1/8"EH .46" 1/4" 1/4"

L

NPT

InternalHEX

HEX

L

NPT - Both Ends

L

HEX

NPTType Dim. L HEX NPTBM .580" 7/16" 1/8"EM .800" 9/16" 1/4"

NPT

L

HEX

NPT

Page 9: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

10

Orifice SizeSize Dia. Number

Number In. Range

4 .00395 .00516 .00597 .00718 .00799 .009110 .010211 .011012 .012213 .013014 .014215 .015016 .01617 .01718 .01819 .01920 .02021 .02122 .02223 .02324 .02425 .02526 .02627 .02728 .02829 .02931 .03132 .03233 .03335 .03537 .03738 .03839 .03940 .04041 .04142 .04243 .04347 .04752 .05255 .05560 .06063 .063

Type IA

INSERTSType AM

Type IC

Metal Orifice Assemblies

Flow DirectionMetal Orifice Assemblies can be usedfor flow in either direction. The data onpages 16, 17 and 18 is for a flow direc-tion as shown in the right column on thispage and also on the top of page 11.Part Numbers

The complete part number for an orifice assembly includes Type, Size Number,Body Material and Options.

EXAMPLESize Body Part

Type Number Material Options Number

IB 6 (.006") SS – IB-6-SS

AM 10 (.010") SS – AM-10-SS

IA 20 (.020") Brass – IA-20-BR

DescriptionThe inserts shown on this page are designedto press-fit into openings accurately machinedin fittings, manifolds and custom parts. Thereis a choice of insert sizes and materials ofconstruction.

ApplicationsThe inserts can be used with a wide variety offittings by accurately machining the inside ofthe fitting. The orifice is then pressed into thefitting for control of the flow rate of liquids orgases.Manifolds or other custom assemblies thatrequire flow rate control of fluids can beaccurately machined to press fit the orificesshown on this page and on the top of page 11.

General SpecificationsMaximum Operating PressureInsert Only Brass – 2000 psig 303SS – 4000 psig 316SS – 4000 psigFlow – See flow chart for air flow on pages16, 17 and 18.Orifice Diameters – .004" to .063". Seechart at right. Consult factory for other sizes.Orifice Diameter Accuracy – ±.0003"Cv Range – .00035 to .088See pages 16, 17 and 18.Fluid Media – Air, Water, Gases and Liquidscompatible with materials of construction.Dimensions – See drawings in right handcolumn of this page and on the top of page 11.Press Fit – See drawings in right handcolumn of this page and on the top of page 11.Materials Type IA – Brass Type I B, I E, I J – 303 SS

I K, U Type IC, I D – 316 SS Type AM, I F, I H – Brass or 303 SS

CONSTRUCTION

DIMENSIONS

CONSTRUCTION

DIMENSIONSType IB

CONSTRUCTION

DIMENSIONS

Type U

CONSTRUCTION

DIMENSIONS

Type AM4-35

Type IA4-63

Type IB4-25

Type IC4-35

Type U4-63

Type ID4-125

Type IE4-35

Type IF4-63

Type IH(metric)

3-64see page 4

Type I J4-125

Type IK4-20

CONSTRUCTION

DIMENSIONS

Press Fit Into .256"/.257" Dia.

.258"/.259" Dia.

.156"

.250"

.125"

.0945"/.0950" Dia..087"/.089" Dia.

Press Fit Into Bore.0930"/.0940" Dia.

.190"

.125"

.1930"/.1935" Dia..184"/.186" Dia.

Press Fit Into Bore.1905"/.1910" Dia.

.280"

Press Fit Into .279"/.280" Bore

19°

.2810"

.2815"

.145" Dia. .128"/.129" Dia.

Press Fit Into.126"/.127" Dia.

.276".196"

Page 10: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

11

Type IC-PC4• For 1/4" OD Metal Tubing• Made from Swagelok Port

Connector• Orifice size numbers 6-63

Type IC-UT4• For 1/4" OD Metal Tubing• Made from Swagelok Union

Tee Tube Fitting• Orifice size numbers 6-63

Type IC-MC4• For 1/4" OD Metal Tubing• Made from Swagelok Male

Connector Tube Fitting• Orifice size numbers 6-63

Type IC-DM4• For 1/4" Applications• Made from 1/4" Swagelok

VCR® Double Male Union• Orifice size numbers 6-63VCR® is a trademark of Cajon/A Swagelok Co.

Metal Orifice AssembliesINSERTS

COMPRESSION FITTINGS

Type IFPress Fit Into.2475" / .2485"

CONSTRUCTION

DIMENSIONS

Size Numbers 4-63See page 10 for orifice sizes

.270

10-32 Thread

.2490

.2495 Dia

Type IEPress Fit Into.1230" / .1235"

CONSTRUCTION

DIMENSIONS

Size Numbers 4-35See page 10 for orifice sizes

.060

.1240

.1250 Dia

Type IDPress Fit Into.4125" / .4135"

CONSTRUCTION

DIMENSIONS

Size Numbers 4-125See page 10 for orifice sizes

10-32 Thread

.440

.4140

.4145 Dia

Type IKPress Fit Into.0605" / .0610"

CONSTRUCTION

DIMENSIONS

Size Numbers 4-20See page 10 for orifice sizes

Type IJPress Fit Into.3785" / .3795"

CONSTRUCTION

DIMENSIONS

Size Numbers 4-125See page 10 for orifice sizes

Type IHPress Fit Into.0980" / .0990"

CONSTRUCTION

Size Numbers 3-64 (metric)See page 4 for orifice sizes

.270

.3800

.3805 Dia

10-32 Thread

.062

.031Spherical R.

.0615

.0625 Dia

Compression fitting Part Numbers – See part number format on Page 10

PORT CONNECTORBody – 316 SSOrifice – 316 SSMax. Body Pressure – 4000 psigMax. Pressure Differential – 1000 psiin direction shown

UNION TEEBody – 316 SSOrifice – 316 SSMax. Body Pressure – 4000 psigMax. Pressure Differential – 200 psi

MALE CONNECTORBody – 316 SSOrifice – 316 SSMax. Body Pressure – 4000 psigMax. Pressure Differential – 1000 psiin direction shown

DOUBLE MALE UNIONBody – 316 SSOrifice – 316 SSMax. Body Pressure – 4000 psigMax. Pressure Differential – 1000 psiin direction shown

.97"

.37" .25"

.74"OrificeInsert

2.12"

OrificeInsert

1.06" 9/16" Hex

OrificeInsert

1/4" NPT

9/16" Hex

1.49"

OrificeInsert

5/8" Hex1.55"

DIMENSIONS

.080

.0995

.1000 Dia

Page 11: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

PART NUMBER SYSTEMTYPE ORIFICE THREADZM — SIZE NO. — SIZE — LENGTH NO. — MATERIAL

DescriptionSet screw style threaded orifice inserts canbe installed in fittings, manifolds or customparts to establish flow rates of liquids orgases. Standard size orifices range from.006" to .063".

Standard SizesOrifice Standard Size Length

Size Dia.* Range Thread Size mm (In.) No.No. In.

6 .00597 .00718 .00799 .009110 .010211 .011012 .012213 .013014 .014215 .015016 .01617 .01718 .01819 .01920 .02021 .02122 .02223 .02324 .02425 .02526 .02627 .02728 .02829 .02931 .03132 .03233 .03335 .03537 .03738 .03839 .03940 .04041 .04142 .04243 .04347 .04752 .05255 .05560 .06063 .063

6-35 M3 4 (.157) 4

6-35 M4 5 (.197) 5

6-63 M5 6 (.236) 6

6-63 M6 8 (.315) 8

6-63 M8 10 (.394) 10

6-63 M10 12 (.472) 12

EXAMPLETYPE SIZE NO. THREAD SIZE LENGTH NO. MATERIAL

1. ZM — 10 — M3 — 4 — SS(Type ZM) (.010" diameter) (4 mm length) (Stainless Steel)

2. ZM — 31 — M6 — 8 — SS(Type ZM) (.031" diameter) (8 mm length) (Stainless Steel)

*Consult factory for larger orifice sizes.

Type ZM

BidirectionalFlow

ThreadSize

OrificeInternalHEX

Length

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

12 Metal Orifice AssembliesTHREADED INSERTS – METRIC

SS18-8 SS

Page 12: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Metal Orifice Assemblies

PART NUMBER SYSTEMTYPE ORIFICE THREAD

Z — SIZE NO. — SIZE — LENGTH NO. — MATERIAL

DescriptionSet screw style threaded orifice inserts canbe installed in fittings, manifolds or customparts to establish flow rates of liquids orgases. Standard size orifices range from.004" to .063". Both brass and 316 SSmaterials are offered.

Standard SizesOrifice Standard Size Length

Size Dia.* Range Thread Size In. No.No. In.

4 .0039 Thread Size No.5 .00516 .00597 .00718 .00799 .009110 .010211 .011012 .012213 .013014 .014215 .015016 .01617 .01718 .01819 .01920 .02021 .02122 .02223 .02324 .02425 .02526 .02627 .02728 .02829 .02931 .03132 .03233 .03335 .03537 .03738 .03839 .03940 .04041 .04142 .04243 .04347 .04752 .05255 .05560 .06063 .063

6 • 32 1/8 2 BR - BrassBrass 4-35 6 • 32 3/16 3SS 6-35 1/4 4 SS - 316SS

8 • 32 1/8 2Brass 4-35 8 • 32 3/16 3SS 6-35 1/4 4

10 • 32 3/16 3Brass 4-63 10 • 32 1/4 4SS 6-63 3/8 6

1/4 • 20 1/4 4Brass 4-63 1/4 • 20 3/8 6SS 6-63 1/2 8

5/16 • 18 1/4 4Brass 4-63 5/16 • 18 3/8 6SS 6-63 1/2 8

3/8 • 16 3/8 6Brass 4-63 3/8 • 16 1/2 8SS 6-63

EXAMPLETYPE SIZE NO. THREAD SIZE LENGTH NO. MATERIAL

1. Z — 10 — 10 • 32 — 6 — BR(Type Z) (.010" diameter) (10 • 32 thread) (3/8" length) (Brass)

2. Z — 31 — 1/4 • 20 — 4 — SS(Type Z) (.031" diameter) (1/4 • 20 thread) (1/4" length) (Stainless Steel)

*Consult factory for larger orifice sizes.

Type Z

BidirectionalFlow

ThreadSize

OrificeInternalHEX

Length

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

13

THREADED INSERTS – INCH

Page 13: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Type K4

Type R4

Type RG4

Type BFS

Type CFJ6

Type OD

The complete part number for an orifice assembly includes Type, Size Number,Body Material and Options.

EXAMPLESize Body Part

Type Number Material Options Number

K4 6 (.006") Stainless Steel – K4-6-SS

R4 13 (.013") Stainless Steel – R4-13-SS

BFS 35 (.035") Brass – BFS-35-BR

CFJ6 104 (.104") Stainless Steel – CFJ6-104-SS

DescriptionPrecision orifice assemblies that adapt tocommon fittings used in process instrumentsand hydraulic systems are shown on pages14 and 15. Types K4, R4 and RG4 are usedwith nominal 1/4" tube fittings. Type BFS isfor 45° flare fittings and Type CFJ6 is for37° flare fittings. Type OD is a pipe adapter.

Applications• Type K4 is a 1/4" OD Tube and is suitable

for use with a wide variety of compressionfittings.

• Types R4 and RG4 are suitable for usewith face seal fittings.

• Types BFS and CFJ6 are used in hydrauliccircuits, having SAE flare connections.

Advantages• High Pressure Capability• Bi-directional Flow• Economical Precision Orifice• Repeatable Orifice Size and Shape• Predictable Flow Rate

General SpecificationsFlow Direction – Suitable for flow in eitherdirection. Data on pages 16 and 17 is meas-ured for flow direction shown in right col-umn of this page.Flow – See flow chart for air flow on pages16 and 17.C

V Range – .00035 to .37

See pages 16 and 17.Orifice Diameter Accuracy – ±.0003"Fluid Media – Air, Water, Gases and Liquidscompatible with materials of construction.Dimensions – See drawings on page 15.Materials of Construction –

See page 15.Maximum Operating Pressure –

See page 15.

Part Numbers

MISCELLANEOUSConstruction

Metal Orifice Assemblies

Orifice SizeSize Dia. Number

Number In. Range4 .00395 .00516 .00597 .00718 .00799 .009110 .010211 .011012 .012213 .013014 .014215 .015016 .01617 .01718 .01819 .01920 .02021 .02122 .02223 .02324 .02425 .02526 .02627 .02728 .02829 .02931 .03132 .03233 .03335 .03537 .03738 .03839 .03940 .04041 .04142 .04243 .04347 .04752 .05255 .05560 .06063 .06367 .06770 .07073 .07376 .07679 .07981 .08186 .08689 .08994 .09496 .096100 .100104 .104109 .109113 .113120 .120125 .125

Type K44-35

Type R44-125

Type RG44-125

Type BFS4-125

Type CFJ64-125

Type OD4-125

14

Page 14: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Metal Orifice Assemblies

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

15

MISCELLANEOUSSpecificationsDimensions

TUBEFor Compression Fittings

Maximum Operating Pressure – 4000 psigMaterial – 316SSOrifice Sizes – .004" to .035" Dia.

CIRCULAR DISKFor Face Seal Fittings

Maximum Operating Pressure – 100 psigMaterial – 316SS/Silver PlatedOrifice Sizes – .004" to .125" Dia.

CIRCULAR DISKWITH RETAINING GASKET

For Face Seal FittingsMaximum Operating Pressure – 100 psigMaterial – Disk • 316SS/Silver Plated

Gasket • 316SSOrifice Sizes – .004" to .125" Dia.

SAE 45° FLARE ADAPTERMaximum Operating Pressure – 2000 psigMaterial – BrassOrifice Sizes – .004" to .125" Dia.

SAE 37° FLARE ADAPTERMaximum Operating Pressure – 4000 psigMaterial – 303SSOrifice Sizes – .004" to .125" Dia.

STRAIGHT THREAD O-RING/FEMALE PIPE ADAPTER

Body/Orifice – BrassO-Ring – VitonMax. Pressure – 2000 psigOrifice Sizes – .004" to .125" Dia.

Type K4

Type R4

Type RG4

Type BFS

Type CFJ6

Type OD

.250" Dia.

1.750"

.030"

.50"

1/8"NPT

1.04"

7/16" HEX

L

.50" .15"

#4 SAE 45° Flare7/16" • 20 Thd

.25"

1/8" NPT

5/8" HEX

Viton O-Ring9/16"-18 UNF Thread

.75"

#6 SAE 37° Flare9/16" • 18 Thd

11/16" HEX

1.19"

.625"

.030"

.47"

Page 15: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

16

P

.O.

BO

X Q

T

RU

MB

UL

L,

CO

NN

EC

TIC

UT

06

61

1

C

T P

HO

NE

(2

03

) 2

61

-67

11

TO

LL

FR

EE

PH

ON

E (

80

0)

53

3-3

28

5

F

AX

(2

03

) 2

61

-83

31

©

O'K

EE

FE

CO

NT

RO

LS

CO

. •

2

00

0 A

LL

RIG

HT

S R

ES

ER

VE

D •

e

-ma

il c

a@

okc

c.co

m

w

eb

site

w

ww

.okc

c.co

m

Met

al O

rific

e A

ir F

low

– S

CF

HO

rific

eD

iam

eter

0.00

40.

005

0.00

60.

007

0.00

80.

009

0.01

00.

011

0.01

20.

013

0.01

40.

015

0.01

60.

017

0.01

80.

019

0.02

00.

021

0.02

20.

023

0.02

40.

025

0.02

60.

027

0.02

80.

029

0.03

10.

032

0.03

3In

ches

Siz

eN

umbe

r4

56

78

910

1112

1314

1516

1718

1920

2122

2324

2526

2728

2931

3233

Cv

0.00

035

0.00

061

0.00

086

0.00

120.

0015

0.00

190.

0025

0.00

280.

0034

0.00

380.

0043

0.00

500.

0055

0.00

670.

0073

0.00

800.

0088

0.00

960.

011

0.01

20.

013

0.01

40.

016

0.01

70.

018

0.01

90.

022

0.02

40.

025

10.

075

0.13

60.

182

0.26

90.

360

0.47

90.

593

0.65

30.

843

0.96

21.

111.

301.

401.

641.

822.

032.

222.

392.

732.

993.

263.

544.

054.

134.

685.

065.

626.

106.

425

0.18

0.33

0.45

0.64

0.85

1.10

1.37

1.51

1.94

2.25

2.56

2.99

3.26

3.73

4.20

4.70

5.23

5.62

6.29

6.87

7.48

8.12

9.20

9.41

10.5

11.3

12.4

13.6

14.4

100.

250.

470.

650.

911.

211.

571.

97 2

.14

2.73

3.14

3.56

4.13

4.26

4.79

5.38

6.00

6.70

7.48

9.17

10.1

11.0

11.8

13.0

13.6

15.2

16.6

18.3

19.9

21.1

150.

340.

590.

821.

141.

531.

972.

482.

673.

433.

924.

455.

175.

306.

046.

847.

568.

509.

3411

.312

.613

.614

.716

.116

.818

.620

.322

.524

.626

.120

0.40

0.70

0.97

1.38

1.80

2.33

2.92

3.16

4.07

4.64

5.28

6.08

6.29

7.20

8.18

9.03

10.3

11.1

13.5

14.7

16.1

17.3

18.9

19.7

21.8

23.7

26.3

28.6

30.3

250.

470.

821.

121.

592.

082.

693.

373.

624.

665.

306.

066.

957.

258.

319.

4310

.411

.812

.715

.516

.818

.319

.921

.622

.724

.827

.130

.132

.634

.530

0.53

0.92

1.26

1.80

2.37

3.03

3.81

4.09

5.23

5.98

6.80

7.82

8.20

9.39

10.7

11.8

13.4

14.4

17.4

19.0

20.7

22.5

24.4

25.4

28.0

30.5

33.7

36.7

39.0

400.

641.

151.

562.

222.

923.

754.

685.

026.

447.

318.

339.

5610

.111

.613

.214

.516

.517

.821

.423

.325

.427

.529

.931

.134

.137

.141

.144

.747

.750

0.76

1.37

1.86

2.67

3.50

4.45

5.55

5.93

7.59

8.62

9.83

11.3

12.1

13.8

15.7

17.3

19.6

21.2

25.2

27.5

30.

1 3

2.6

35.2

36.7

40.3

43.9

48.5

53.0

56.4

600.

891.

592.

163.

094.

055.

136.

406.

848.

7510

.011

.313

.014

.016

.018

.220

.022

.724

.629

.231

.834

.737

.540

.742

.446

.450

.455

.961

.065

.070

1.02

1.82

2.46

3.54

4.60

5.83

7.27

7.76

9.92

11.3

12.8

14.7

16.0

18.2

20.7

22.9

25.9

28.0

33.1

36.0

39.2

42.6

46.0

48.1

52.5

57.2

63.6

69.3

73.9

801.

142.

042.

753.

965.

156.

538.

128.

6711

.112

.614

.316

.517

.920

.523

.325

.629

.031

.637

.140

.343

.947

.751

.353

.658

.764

.071

.277

.882

.690

1.27

2.27

3.05

4.41

5.70

7.20

8.96

9.56

12.2

13.9

15.9

18.3

19.9

22.7

25.9

28.4

32.2

35.0

40.9

44.5

48.5

52.8

56.8

59.3

65.0

71.0

78.8

86.0

91.5

100

1.40

2.48

3.3

54.

836.

257.

889.

8110

.513

.415

.317

.420

.021

.825

.028

.431

.135

.238

.144

.748

.753

.258

.162

.365

.371

.478

.086

.794

.510

15

0.11

30.

203

0.27

30.

405

0.53

60.

703

0.86

00.

953

1.23

1.40

1.64

1.90

2.07

2.41

2.70

2.99

3.28

3.60

4.03

4.45

4.87

5.2

55.

81 6

.00

6.70

7.23

8.0

1 8

.73

9.15

10 0

.145

0.26

30.

356

0.52

10.

687

0.89

21.

101.

201.

551.

772.

062.

372.

622.

993.

353.

794.

154.

625.

175.

686.

126.

63 7

.29

7.59

8.48

9.1

110

.110

.911

.515

0.15

8 0

.284

0.39

20.

568

0.74

40.

964

1.20

1.30

1.68

1.91

2.26

2.59

2.86

3.28

3.71

4.11

4.64

4.92

5.53

6.04

6.61

7.08

7.73

8.01

8.90

9.56

10.7

11.5

12.1

200.

158

0.28

40.

392

0.56

80.

744

0.96

41.

201.

301.

681.

91 2

.26

2.59

2.86

3.28

3.71

4.11

4.64

4.92

5.53

6.04

6.61

7.08

7.73

8.01

8.90

9.56

10.7

11.5

12.1

300.

158

0.28

40.

392

0.56

80.

744

0.96

41.

201.

301.

681.

912.

262.

592.

863.

283.

714.

114.

644.

925.

536.

046.

617.

087.

738.

018.

909.

5610

.711

.512

.1

Supply Pressure – psig

Choked Flow

Vacuum LevelIn. Hg. Supply Pressure – psig

Choked Flow

Orif

ice

Dia

met

er0.

035

0.03

70.

038

0.03

90.

040

0.04

10.

042

0.04

30.

047

0.05

20.

055

0.06

00.

063

0.06

70.

070

0.07

30.

076

0.07

90.

081

0.08

60.

089

0.09

40.

096

0.10

00.

104

0.10

90.

113

0.12

00.

125

Inch

es

Siz

eN

umbe

r35

3738

3940

4142

4347

52

55 6

063

6770

7376

7981

8689

9496

100

104

109

113

120

125

Cv

0.02

80.

031

0.0

320.

033

0.03

60.

038

0.03

90.

041

0.04

80.

059

0.06

80.

081

0.08

80.

100.

110.

120.

13 0

.14

0.15

0.17

0.18

0.20

0.21

0.2

3 0

.25

0.27

0.31

0.34

0.37

17.

378.

128.

75 9

.45

9.75

9.90

10.6

11.4

13.6

17.0

19.9

23.

725

.930

.133

.635

.939

.343

.0 4

6.0

49.

753

.760

.2 6

3.7

69.8

75.2

83.9

91.

410

110

65

16.3

18.0

19.3

20.6

21.6

22.

5 2

3.9

25.

630

.137

.343

.050

.655

.364

.271

.676

.583

.5 9

1.3

97.5

108

116

131

138

150

162

180

195

216

229

1022

.5 2

5.0

26.5

28.

830

.5 3

1.4

33.1

35.6

41.0

51.9

57.4

68.2

74.6

86.2

96.6

103

112

121

131

144

153

172

181

196

216

237

250

286

314

1527

.830

.732

.635

.437

.538

.640

.543

.250

.062

.969

.782

.690

.310

411

712

513

614

715

817

418

520

721

823

526

1 2

86 3

0334

537

720

32.4

36.0

38.4

41.5

44.3

45.3

47.

750

.9 5

8.7

74.2

82.0

97.3

106

123

138

146

160

172

185

203

216

242

256

275

305

33

535

440

344

525

37.5

41.

544

.147

.9 5

0.9

52.3

54.

958

.5 6

7.6

85.

494

.511

212

214

115

816

818

319

821

223

3 2

48 2

78 2

9231

6 3

4738

140

546

4 5

1130

42.4

47.0

50.0

54.2

57.6

59.3

62.3

66.3

76.3

96.6

107

126

138

160

179

190

206

222

239

265

280

314

331

356

392

432

458

525

578

4052

.558

.167

.267

.071

.273

.376

.982

.094

.311

913

215

617

019

622

023

325

427

329

532

434

338

440

543

9 4

8353

256

6 6

48 7

1450

62.5

69.

173

.779

.785

.087

.591

.797

.511

214

215

718

520

223

326

127

8 3

0132

434

738

440

745

648

152

357

663

467

277

185

060

72.7

80.5

86.

0 9

2.8

9910

210

711

313

016

518

2 2

1423

326

930

132

034

737

540

044

5 4

73 5

3055

960

666

773

578

089

498

570

83.1

91.7

98.

110

611

311

712

212

914

818

720

7 2

44 2

6730

734

336

239

442

845

8 5

09 5

38 6

04 6

3869

3 7

63 8

39 8

9210

2111

2580

9310

311

011

912

713

113

714

516

721

023

1 2

7329

834

338

440

544

348

151

357

0 6

04 6

7871

677

885

694

310

0011

4612

6390

106

115

122

132

141

146

151

161

185

231

256

303

331

379

424

447

489

532

568

631

670

750

792

860

947

1042

1106

1267

1398

100

114

126

135

146

156

164

167

177

203

254

282

331

362

415

468

496

540

587

627

697

739

831

875

951

1047

1153

1225

1403

1545

510

.411

.412

.313

.314

.314

.515

.416

.319

.2 2

3.9

26.4

31.

4 3

6.2

42.4

47.7

50.6

55.

160

.064

.070

.376

.184

.988

.6 9

6.1

104

114

123

138

150

1013

.114

.415

.416

.617

.618

.019

.2 2

0.3

23.6

29.4

32.7

38.6

44.

9 5

1.7

57.6

63.

468

.974

.879

.987

.994

.910

611

012

013

014

215

317

318

715

13.8

15.2

16.2

17.4

18.3

18.8

20.0

21.1

24.

530

.533

.739

.446

.854

.060

.266

.171

.878

.083

.591

.799

.011

011

512

513

514

816

018

019

520

13.8

15.2

16.2

17.4

18.3

18.8

20.0

21.1

24.5

30.5

33.7

39.4

46.8

54.

060

.266

.171

.878

.0 8

3.5

91.7

99.0

110

115

125

135

148

160

180

195

3013

.815

.216

.217

.418

.318

.8 2

0.0

21.1

24.5

30.5

33.7

39.4

46.8

54.0

60.

266

.171

.878

.0 8

3.5

91.

799

.011

011

512

513

514

816

018

019

5

Vacuum LevelIn. Hg.

Sta

nd

ard

Co

nd

itio

ns

70

°F,

14

.7 p

sia

SC

FH

– S

tan

da

rd C

u.

Ft.

Pe

r H

ou

rA

bo

ve d

ata

ob

tain

ed

with

Typ

e B

re

stri

cto

r. F

low

ra

tes

for

oth

er

me

tal r

est

rict

ors

are

SL

PM

– S

tan

da

rd L

iters

Pe

r M

inu

tee

sse

ntia

lly t

he

sa

me

as

for

Typ

e B

. A

bo

ve d

ata

su

pe

rce

de

s p

revi

ou

s p

ub

lica

tion

s.

Page 16: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

17

Met

al O

rific

e A

ir F

low

– S

LPM

Orif

ice

Dia

met

er0.

004

0.00

50.

006

0.00

70.

008

0.00

90.

010

0.01

10.

012

0.01

30.

014

0.01

50.

016

0.01

70.

018

0.01

90.

020

0.02

10.

022

0.02

30.

024

0.02

50.

026

0.02

70.

028

0.02

90.

031

0.03

20.

033

Inch

es

Siz

eN

umbe

r4

56

78

910

1112

1314

1516

1718

1920

2122

2324

2526

2728

2931

3233

Cv

0.00

035

0.00

061

0.00

086

0.00

120.

0015

0.00

190.

0025

0.00

280.

0034

0.00

380.

0043

0.00

500.

0055

0.00

670.

0073

0.00

800.

0088

0.00

960.

011

0.01

20.

013

0.01

40.

016

0.01

70.

018

0.01

90.

022

0.02

40.

025

10.

035

0.06

40.

086

0.12

70.

170

0.22

60.

280

0.30

80.

398

0.45

0.52

0.61

0.66

0.77

0.86

0.96

1.05

1.13

1.29

1.41

1.54

1.67

1.91

1.95

2.21

2.39

2.65

2.88

3.03

50.

090.

160.

210.

300.

400.

520.

650.

710.

921.

061.

211.

411.

541.

761.

982.

222.

472.

652.

973.

243.

53 3

.83

4.34

4.44

4.94

5.31

5.86

6.42

6.80

100.

120.

220.

310.

430.

570.

740.

931.

011.

291.

481.

681.

952.

012.

262.

542.

833.

163.

534.

334.

755.

185.

556.

156.

437.

187.

838.

639.

409.

9815

0.16

0.28

0.39

0.54

0.72

0.93

1.17

1.26

1.62

1.85

2.10

2.44

2.50

2.85

3.23

3.57

4.01

4.41

5.35

5.93

6.43

6.95

7.58

7.95

8.78

9.58

10.6

11.6

12.3

200.

190.

330.

460.

650.

851.

101.

381.

491.

922.

192.

492.

872.

973.

403.

864.

264.

845.

226.

356.

957.

588.

158.

909.

2810

.311

.212

.413

.514

.325

0.22

0.39

0.53

0.75

0.98

1.27

1.59

1.71

2.20

2.50

2.86

3.28

3.42

3.92

4.45

4.91

5.59

6.01

7.30

7.95

8.65

9.38

10.2

10.7

11.7

12.8

14.2

15.4

16.3

300.

250.

440.

600.

851.

121.

431.

801.

932.

472.

823.

213.

693.

874.

435.

035.

566.

336.

818.

238.

989.

7510

.611

.512

.013

.214

.415

.917

.318

.440

0.30

0.54

0.74

1.05

1.38

1.77

2.21

2.37

3.04

3.45

3.93

4.51

4.78

5.47

6.21

6.85

7.81

8.42

10.1

11.0

12.0

13.0

14.1

14.7

16.1

17.5

19.4

21.1

22.5

500.

360.

650.

881.

261.

652.

102.

622.

803.

584.

074.

645.

315.

706.

517.

408.

159.

2610

.011

.913

.014

.215

.416

.617

.319

.020

.722

.925

.026

.660

0.42

0.75

1.02

1.46

1.91

2.42

3.02

3.23

4.13

4.70

5.34

6.13

6.61

7.56

8.58

9.46

10.7

11.6

13.8

15.0

16.4

17.7

19.2

20.0

21.9

23.8

26.4

28.8

30.7

700.

480.

861.

161.

672.

172.

753.

433.

664.

685.

326.

056.

967.

538.

619.

7710

.812

.213

.215

.617

.018

.520

.121

.722

.724

.827

.030

.032

.734

.980

0.54

0.96

1.30

1.87

2.43

3.08

3.83

4.09

5.23

5.95

6.77

7.79

8.46

9.67

11.0

12.1

13.7

14.9

17.5

19.0

20.7

22.5

24.2

25.3

27.7

30.2

33.6

36.7

39.0

900.

601.

071.

44 2

.08

2.69

3.40

4.23

4.51

5.7

86.

587.

49 8

.62

9.38

10.7

12.2

13.4

15.2

16.5

19.3

21.0

22.

924

.9 2

6.8

28.0

30.7

33.5

37.

240

.643

.210

00.

66 1

.17

1.58

2.2

82.

953.

724.

634.

94 6

.33

7.22

8.21

9.46

10.3

11.8

13.4

14.7

16.6

18.0

21.1

23.0

25.1

27.

429

.430

.833

.736

.840

.944

.647

.55

0.05

30.

096

0.12

90.

191

0.25

30.

332

0.40

60.

450

0.58

20.

661

0.7

730.

899

0.97

71.

141.

281.

411.

551.

701.

902.

10 2

.30

2.48

2.74

2.83

3.16

3.41

3.78

4.12

4.32

10

0.06

90.

124

0.16

80.

246

0.32

40.

421

0.51

90.

564

0.73

00.

834

0.97

21.

12 1

.24

1.41

1.5

81.

791.

962.

182.

442.

682.

893.

133.

443.

584.

004.

304.

775.

165.

4315

0.07

50.

134

0.1

850.

268

0.35

10.

455

0.56

60.

614

0.79

2 0

.902

1.07

1.22

1.35

1.5

51.

751.

942.

19 2

.32

2.6

12.

853.

12 3

.34

3.65

3.78

4.20

4.51

5.05

5.4

55.

7220

0.07

50.

134

0.1

850.

268

0.35

10.

455

0.56

60.

614

0.79

20.

902

1.07

1.22

1.35

1.55

1.75

1.94

2.19

2.32

2.6

12.

853.

123.

343.

653.

784.

204.

515.

055.

455.

7230

0.07

50.

134

0.18

50.

268

0.35

10.

455

0.56

60.

614

0.79

20.

902

1.07

1.22

1.35

1.55

1.75

1.94

2.19

2.32

2.61

2.8

53.

123.

343.

653.

784.

20 4

.51

5.05

5.45

5.72

Supply Pressure – psig

Choked Flow

Vacuum LevelIn. Hg. Supply Pressure – psig

Choked Flow

Orif

ice

Dia

met

er0.

035

0.03

70.

038

0.03

90.

040

0.04

10.

042

0.04

30.

047

0.05

20.

055

0.06

00.

063

0.06

70.

070

0.07

30.

076

0.07

90.

081

0.08

60.

089

0.09

40.

096

0.10

00.

104

0.10

90.

113

0.12

00.

125

Inch

es

Siz

eN

umbe

r35

3738

3940

4142

4347

52

55 6

063

6770

7376

7981

8689

9496

100

104

109

113

120

125

Cv

0.02

80.

031

0.0

320.

033

0.03

60.

038

0.03

90.

041

0.04

80.

059

0.06

80.

081

0.08

80.

100.

110.

120.

13 0

.14

0.15

0.17

0.18

0.20

0.21

0.2

3 0

.25

0.27

0.31

0.34

0.37

13.

483.

834.

13 4

.46

4.60

4.67

4.99

5.36

6.4

38.

049.

4011

.212

.214

.215

.916

.918

.520

.321

.723

.525

.428

.430

.132

.935

.539

.643

.147

.850

.15

7.67

8.48

9.0

99.

7010

.210

.611

.312

.114

.217

.620

.3 2

3.9

26.1

30.3

33.

836

.139

.443

.146

.0 5

1.1

54.9

61.9

65.0

70.8

76.6

84.8

92.

110

210

810

10.6

11.8

12.5

13.6

14.4

14.8

15.6

16.8

19.4

24.

527

.132

.235

.240

.745

.648

.552

.957

.361

.667

.9 7

2.3

81.0

85.5

92.3

102

112

118

135

148

1513

.114

.515

.416

.717

.718

.219

.120

.4 2

3.6

29.7

32.9

39.0

42.6

49.3

55.

358

.864

.069

.474

.582

.187

.397

.810

311

112

313

514

316

317

820

15.3

17.0

18.1

19.6

20.9

21.

422

.524

.027

.735

.0 3

8.7

45.9

50.1

58.0

65.0

69.0

75.3

81.4

87.3

95.6

102

114

121

130

144

158

167

190

210

2517

.719

.620

.822

.624

.024

.725

.927

.631

.940

.344

.652

.857

.766

.774

.779

.386

.493

.510

011

011

713

113

814

916

418

019

121

924

130

20.0

22.

223

.625

.627

.228

.029

.431

.336

.045

.650

.459

.765

.275

.484

.389

.597

.410

511

312

513

214

815

616

818

520

421

624

827

340

24.8

27.4

31.7

31.6

33.6

34.6

36.3

38.7

44.5

56.3

62.2

73.6

80.3

92.

710

411

012

012

913

915

316

218

119

120

722

825

126

730

633

750

29.5

32.

634

.837

.640

.141

.343

.346

.052

.966

.974

.087

.495

.411

012

313

114

215

316

418

119

2 2

1522

724

727

2 2

9931

736

440

160

34.3

38.0

40.6

43.8

46.7

48.1

50.3

53.5

61.5

77.7

85.8

101

110

127

142

151

164

177

189

210

223

250

264

286

315

347

368

422

465

7039

.243

.346

.350

.053

.3 5

5.0

57.4

61.

070

.088

.497

.611

512

614

516

217

118

620

221

624

025

428

530

132

736

039

642

148

253

180

44.0

48.

752

.156

.260

.061

.9 6

4.5

68.5

78.6

99.1

109

129

141

162

181

191

209

227

242

269

285

320

338

367

404

445

472

541

596

9050

.054

.2 5

7.8

62.4

66.7

68.9

71.5

76.0

87.2

109

121

143

156

179

200

211

231

251

268

298

316

354

374

406

447

492

522

598

660

100

53.9

59.6

63.7

68.7

73.5

77.3

78.6

83.5

95.8

120

133

156

171

196

221

234

255

277

296

329

349

392

413

449

494

544

578

662

729

54.

925.

405.

816.

296.

766.

827.

297.

679.

0811

.312

.414

.817

.120

.0 2

2.5

23.9

26.0

28.

330

.233

.235

.940

.141

.845

.349

.053

.957

.965

.370

.910

6.18

6.78

7.29

7.8

58.

318.

509.

089.

5811

.113

.915

.418

.221

.224

.427

.229

.9 3

2.5

35.3

37.7

41.5

44.8

50.0

52.1

56.6

61.2

67.2

72.2

81.4

88.4

156.

507.

177.

638.

228.

668.

879.

4610

.011

.614

.415

.918

.622

.125

.528

.431

.233

.936

.839

.443

.346

.752

.154

.459

.063

.870

.175

.384

.992

.220

6.50

7.1

77.

638.

228.

66 8

.87

9.46

10.0

11.6

14.4

15.9

18.6

22.1

25.5

28.4

31.2

33.9

36.8

39.4

43.3

46.7

52.1

54.4

59.0

63.8

70.1

75.3

84.9

92.2

306.

50 7

.17

7.63

8.22

8.66

8.87

9.46

10.0

11.6

14.4

15.9

18.6

22.1

25.5

28.4

31.2

33.9

36.8

39.4

43.3

46.7

52.1

54.4

59.0

63.8

70.1

75.3

84.9

92.2

Vacuum LevelIn. Hg.

Sta

nd

ard

Co

nd

itio

ns

70

°F,

14

.7 p

sia

SC

FH

– S

tan

da

rd C

u.

Ft.

Pe

r H

ou

rA

bo

ve d

ata

ob

tain

ed

with

Typ

e B

re

stri

cto

r. F

low

ra

tes

for

oth

er

me

tal r

est

rict

ors

are

SL

PM

– S

tan

da

rd L

iters

Pe

r M

inu

tee

sse

ntia

lly t

he

sa

me

as

for

Typ

e B

. A

bo

ve d

ata

su

pe

rce

de

s p

revi

ou

s p

ub

lica

tion

s.

P

.O.

BO

X Q

T

RU

MB

UL

L,

CO

NN

EC

TIC

UT

06

61

1

C

T P

HO

NE

(2

03

) 2

61

-67

11

TO

LL

FR

EE

PH

ON

E (

80

0)

53

3-3

28

5

F

AX

(2

03

) 2

61

-83

31

©

O'K

EE

FE

CO

NT

RO

LS

CO

. •

2

00

0 A

LL

RIG

HT

S R

ES

ER

VE

D •

e

-ma

il c

a@

okc

c.co

m

w

eb

site

w

ww

.okc

c.co

m

Page 17: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

18

P

.O.

BO

X Q

T

RU

MB

UL

L,

CO

NN

EC

TIC

UT

06

61

1

C

T P

HO

NE

(2

03

) 2

61

-67

11

TO

LL

FR

EE

PH

ON

E (

80

0)

53

3-3

28

5

F

AX

(2

03

) 2

61

-83

31

©

O'K

EE

FE

CO

NT

RO

LS

CO

. •

2

00

0 A

LL

RIG

HT

S R

ES

ER

VE

D •

e

-ma

il c

a@

okc

c.co

m

w

eb

site

w

ww

.okc

c.co

m

Sap

phire

Orif

ice

Air

Flo

w –

SLP

MO

rific

eD

iam

eter

0.00

120.

0016

0.00

200.

0024

0.00

280.

0031

0.00

350.

0039

0.00

430.

0047

0.00

510.

0055

0.00

590.

0063

0.00

670.

0071

0.00

790.

0087

0.00

940.

0102

0.01

100.

0118

0.01

260.

0134

0.01

420.

0157

0.01

730.

0189

0.02

050.

0213

0.02

280.

0252

Inch

es

Size

Num

ber

34

56

78

910

1112

1314

1516

1718

2022

2426

2830

3234

3640

4448

5254

5864

Cv

0.00

0030

0.00

0053

0.00

0090

0.00

012

0.00

017

0.00

022

0.00

028

0.00

035

0.00

042

0.00

050

0.00

061

0.00

071

0.00

084

0.00

094

0.00

110.

0012

0.00

150.

0018

0.00

210.

0024

0.00

280.

0032

0.00

360.

0040

0.00

460.

0057

0.00

670.

0080

0.00

910.

010

0.01

10.

013

10.

003

0.00

50.

010

0.01

40.

020

0.02

50.

034

0.04

00.

050

0.05

80.

068

0.08

00.

095

0.10

60.

120

0.13

90.

161

0.19

40.

259

0.27

50.

300

0.34

00.

393

0.44

60.

499

0.67

70.

822

0.96

51.

101.

121.

381.

69

50.

009

0.01

30.

027

0.03

60.

047

0.05

90.

076

0.09

30.

108

0.13

60.

159

0.19

20.

223

0.25

60.

273

0.31

30.

350

0.43

00.

584

0.62

30.

695

0.80

00.

933

1.06

1.20

1.51

1.81

2.16

2.50

2.57

3.26

4.06

100.

010

0.01

60.

036

0.04

90.

065

0.08

20.

107

0.13

20.

164

0.19

30.

228

0.26

40.

308

0.35

70.

382

0.43

00.

480

0.59

00.

830

0.86

80.

968

1.09

1.27

1.45

1.63

2.01

2.43

2.90

3.32

3.45

4.43

5.58

150.

014

0.02

10.

046

0.06

20.

082

0.10

40.

134

0.16

60.

205

0.24

00.

285

0.32

90.

386

0.44

30.

482

0.53

50.

613

0.75

51.

051.

111.

241.

421.

631.

852.

092.

563.

083.

694.

264.

435.

557.

0820

0.01

60.

025

0.05

50.

074

0.09

90.

125

0.15

90.

197

0.24

30.

284

0.33

70.

390

0.45

70.

525

0.56

90.

635

0.73

00.

910

1.25

1.32

1.48

1.70

1.95

2.20

2.48

3.04

3.64

4.36

5.06

5.31

6.55

8.33

250.

019

0.03

00.

063

0.08

70.

115

0.14

40.

184

0.22

90.

280

0.32

70.

389

0.45

00.

526

0.60

50.

654

0.73

30.

843

1.05

1.44

1.52

1.70

1.95

2.24

2.52

2.84

3.50

4.19

5.03

5.81

6.11

7.53

9.55

300.

022

0.03

40.

072

0.09

80.

132

0.16

40.

208

0.26

00.

317

0.37

00.

440

0.51

10.

595

0.68

50.

710

0.83

80.

958

1.19

1.63

1.69

1.91

2.19

2.52

2.84

3.19

3.96

4.75

5.69

6.57

6.90

8.48

10.7

400.

027

0.04

30.

089

0.12

20.

163

0.20

30.

257

0.32

10.

390

0.45

60.

543

0.63

20.

734

0.84

50.

880

1.04

1.18

1.47

2.02

2.11

2.35

2.67

3.07

3.46

3.90

4.89

5.86

7.02

8.10

8.50

10.4

13.1

500.

032

0.05

20.

106

0.14

70.

195

0.24

10.

306

0.38

30.

463

0.54

20.

652

0.75

30.

872

1.00

1.05

1.24

1.41

1.75

2.39

2.50

2.78

3.16

3.63

4.08

4.59

5.83

6.96

8.35

9.63

10.1

12.3

15.5

600.

037

0.06

10.

123

0.17

10.

227

0.28

00.

356

0.44

50.

536

0.63

00.

751

0.87

51.

011.

161.

231.

451.

642.

032.

772.

893.

203.

634.

174.

695.

296.

778.

109.

6911

.111

.714

.217

.9

700.

042

0.07

00.

141

0.19

50.

259

0.31

80.

403

0.50

70.

609

0.71

70.

855

0.99

61.

151.

321.

401.

661.

872.

313.

143.

283.

624.

124.

725.

315.

997.

719.

2311

.012

.713

.316

.020

.2

800.

047

0.08

00.

158

0.20

00.

292

0.35

70.

453

0.56

90.

683

0.80

40.

959

1.12

1.28

1.48

1.57

1.86

2.09

2.59

3.51

3.66

4.04

4.68

5.28

5.93

6.69

8.65

10.4

12.3

14.3

14.8

17.9

22.6

900.

053

0.08

90.

175

0.24

40.

324

0.39

60.

502

0.63

20.

757

0.89

11.

061.

241.

421.

641.

752.

062.

322.

873.

894.

054.

475.

075.

836.

567.

419.

6011

.513

.715

.716

.419

.724

.9

100

0.05

80.

098

0.19

30.

269

0.35

60.

435

0.55

10.

692

0.83

00.

978

1.17

1.36

1.56

1.80

1.92

2.27

2.55

3.15

4.26

4.44

4.89

5.57

6.38

7.18

8.12

10.6

12.6

15.0

17.2

18.0

21.6

27.3

50.

003

0.00

60.

014

0.02

00.

028

0.03

60.

047

0.05

70.

073

0.08

50.

100

0.11

60.

137

0.15

60.

169

0.19

90.

229

0.27

70.

377

0.40

10.

451

0.51

00.

591

0.67

30.

764

0.98

21.

161.

381.

611.

642.

132.

61

10

0.00

40.

008

0.01

80.

027

0.03

60.

046

0.06

10.

073

0.09

30.

109

0.12

80.

149

0.17

50.

200

0.21

70.

253

0.29

20.

352

0.48

20.

503

0.55

60.

638

0.73

40.

833

0.95

51.

261.

511.

802.

062.

112.

553.

19

150.

006

0.01

0 0

.021

0.03

00.

040

0.05

00.

065

0.07

90.

100

0.1

170.

138

0.15

90.

188

0.21

40.

235

0.26

90.

320

0.39

00.

525

0.55

40.

626

0.71

10.

818

0.92

11.

071.

391.

651.

992.

312.

392.

773.

48

200.

006

0.01

0 0

.021

0.03

00.

040

0.05

00.

065

0.07

90.

100

0.11

70.

138

0.15

90.

188

0.21

40.

235

0.26

90.

320

0.39

00.

525

0.55

40.

626

0.71

10.

818

0.92

11.

071.

391.

651.

992.

312.

392.

773.

48

300.

006

0.01

00.

021

0.03

00.

040

0.05

00.

065

0.07

90.

100

0.11

70.

138

0.15

90.

188

0.21

40.

235

0.26

90.

320

0.39

00.

525

0.55

40.

626

0.71

10.

818

0.92

11.

071.

391.

651.

992.

312.

392.

773.

48

Supply Pressure – psig

Choked Flow

Supply Pressure – psig

Choked Flow

Orif

ice

Dia

met

er0.

0012

0.00

160.

0020

0.00

240.

0028

0.00

310.

0035

0.00

390.

0043

0.00

470.

0051

0.00

550.

0059

0.00

630.

0067

0.00

710.

0079

0.00

870.

0094

0.01

020.

0110

0.01

180.

0126

0.01

340.

0142

0.01

570.

0173

0.01

890.

0205

0.02

130.

0228

0.02

52

Inch

es

Siz

eN

umbe

r3

45

67

89

1011

1213

1415

1617

1820

2224

2628

3032

3436

4044

4852

5458

64

Cv

0.00

0030

0.00

0053

0.00

0090

0.00

012

0.00

017

0.00

022

0.00

028

0.00

035

0.00

042

0.00

050

0.00

061

0.00

071

0.00

084

0.00

094

0.00

110.

0012

0.00

150.

0018

0.00

210.

0024

0.00

280.

0032

0.00

360.

0040

0.00

460.

0057

0.00

670.

0080

0.00

910.

010

0.01

10.

013

10.

007

0.01

10.

021

0.03

00.

042

0.05

30.

072

0.08

50.

106

0.12

30.

144

0.16

90.

201

0.22

50.

254

0.29

40.

341

0.41

10.

549

0.58

30.

636

0.72

00.

833

0.94

51.

061.

431.

742.

042.

332.

372.

923.

58

50.

019

0.02

70.

056

0.07

50.

100

0.12

40.

161

0.19

70.

228

0.28

80.

337

0.40

70.

471

0.54

20.

577

0.66

30.

740

0.91

11.

241.

321.

471.

701.

982.

252.

533.

203.

834.

585.

305.

446.

908.

60

100.

021

0.03

40.

076

0.10

40.

138

0.17

40.

227

0.28

00.

347

0.40

90.

483

0.55

90.

653

0.75

60.

809

0.91

11.

021.

251.

761.

842.

052.

312.

693.

073.

454.

265.

156.

147.

037.

319.

3911

.8

150.

030

0.04

40.

097

0.13

10.

174

0.22

00.

284

0.35

20.

434

0.50

80.

604

0.69

70.

818

0.93

91.

021.

131.

301.

602.

222.

352.

633.

013.

453.

924.

435.

426.

537.

829.

039.

3911

.815

.020

0.03

40.

053

0.11

70.

157

0.21

00.

265

0.33

70.

417

0.51

50.

602

0.71

40.

826

0.96

81.

111.

211.

351.

551.

932.

652.

803.

143.

604.

134.

665.

256.

447.

719.

2410

.711

.313

.917

.6

250.

040

0.06

40.

133

0.18

40.

244

0.30

50.

390

0.48

50.

593

0.69

30.

824

0.95

31.

111.

281.

391.

551.

792.

223.

053.

223.

604.

134.

755.

346.

027.

428.

8810

.712

.312

.916

.020

.2

300.

046

0.07

20.

152

0.20

80.

280

0.34

70.

441

0.55

10.

672

0.78

40.

932

1.08

1.26

1.45

1.50

1.78

2.03

2.52

3.45

3.58

4.05

4.64

5.34

6.02

6.76

8.39

10.1

12.1

13.9

14.6

18.0

22.7

400.

057

0.09

10.

189

0.25

80.

345

0.43

00.

544

0.68

00.

826

0.96

61.

151.

341.

561.

791.

862.

202.

503.

114.

284.

474.

985.

666.

507.

338.

2610

.412

.414

.917

.218

.022

.027

.8

500.

068

0.11

00.

225

0.31

10.

413

0.51

10.

648

0.81

10.

981

1.15

1.38

1.60

1.85

2.13

2.22

2.63

2.99

3.71

5.06

5.30

5.89

6.69

7.69

8.64

9.72

12.4

14.7

17.7

20.4

21.4

26.1

32.8

600.

079

0.12

90.

261

0.36

20.

481

0.59

30.

754

0.94

31.

141.

331.

591.

852.

142.

462.

613.

073.

474.

305.

876.

126.

787.

698.

839.

9411

.214

.317

.220

.523

.524

.830

.137

.9

700.

089

0.14

90.

299

0.41

30.

549

0.67

40.

854

1.07

1.29

1.52

1.81

2.11

2.43

2.80

2.97

3.52

3.96

4.89

6.65

6.95

7.67

8.73

10.0

11.3

12.7

16.3

19.6

23.3

26.9

28.2

33.9

42.8

800.

100

0.16

80.

335

0.42

40.

619

0.75

60.

960

1.21

1.45

1.70

2.03

2.37

2.72

3.13

3.33

3.94

4.43

5.49

7.44

7.75

8.56

9.75

11.2

12.6

14.2

18.3

22.0

26.1

30.3

31.4

37.9

47.9

900.

111

0.18

80.

371

0.51

70.

686

0.83

91.

061.

341.

601.

892.

252.

623.

013.

473.

714.

364.

926.

088.

248.

589.

4710

.712

.413

.915

.720

.324

.429

.033

.334

.741

.752

.8

100

0.12

20.

208

0.40

90.

570

0.75

40.

922

1.17

1.47

1.76

2.07

2.47

2.88

3.30

3.81

4.07

4.81

5.40

6.67

9.03

9.41

10.4

11.

813

.515

.217

.222

.526

.731

.836

.438

.145

.857

.8

50.

007

0.01

30.

029

0.04

30.

059

0.07

60.

100

0.12

10.

154

0.18

00.

212

0.24

60.

290

0.33

10.

358

0.42

20.

485

0.58

70.

799

0.85

00.

956

1.08

1.25

1.43

1.62

2.08

2.46

2.92

3.41

3.47

4.51

5.53

100.

009

0.01

80.

039

0.05

70.

076

0.09

80.

128

0.15

50.

197

0.23

10.

271

0.31

60.

371

0.42

40.

460

0.53

60.

619

0.74

61.

021.

071.

181.

351.

561.

762.

022.

673.

193.

814.

364.

475.

406.

76

150.

012

0.02

00.

045

0.06

30.

085

0.10

70.

138

0.16

80.

212

0.24

80.

292

0.33

70.

398

0.45

30.

498

0.57

00.

678

0.82

61.

111.

171.

331.

511.

731.

952.

262.

953.

504.

224.

895.

065.

877.

37

200.

012

0.02

00.

045

0.06

30.

085

0.10

70.

138

0.16

80.

212

0.24

80.

292

0.33

70.

398

0.45

30.

498

0.57

00.

678

0.82

61.

111.

171.

331.

511.

731.

952.

262.

953.

504.

224.

895.

065.

877.

37

300.

012

0.02

00.

045

0.06

30.

085

0.10

70.

138

0.16

80.

212

0.24

80.

292

0.33

70.

398

0.45

30.

498

0.57

00.

678

0.82

61.

111.

171.

331.

511.

731.

952.

262.

953.

504.

224.

895.

065.

877.

37

Vacuum LevelIn. Hg.

Sta

nd

ard

Co

nd

itio

ns

70

°F,

14

.7 p

sia

SC

FH

– S

tan

da

rd C

u.

Ft.

Pe

r H

ou

rA

bo

ve d

ata

ob

tain

ed

with

Typ

e S

re

stri

cto

r. F

low

ra

tes

for

Typ

e A

, B

TF

, B

WF

, F

, J,

SL

PM

– S

tan

da

rd L

iters

Pe

r M

inu

teL

, P

, a

nd

SF

re

stri

cto

rs a

re e

sse

ntia

lly t

he

sa

me

as

for

Typ

e S

.A

bo

ve d

ata

su

pe

rce

de

s p

revi

ou

s p

ub

lica

tion

s.

Sap

phire

Orif

ice

Air

Flo

w –

SC

FH

Vacuum LevelIn. Hg.

Page 18: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Type BLP - 1/8" NPT Nipple

Type MLP - 10-32 x 1/16" Barb

DimensionsType BLP

Type MLP

Type QXLP

Type IBLP

Construction

Type BLP

Type MLP

Type QXLP

Type IBLP

.0003" to .0050" DIA.

Precision Micro-Orifices®

DescriptionThe Precision Micro-Orifices® are con-structed of brass or stainless steel withorifice sizes from .0003" to .005" diameter.The orifices are used to accurately metervery low flow rates of gases or liquids.Optional stainless steel screens are avail-able to protect the tiny orifices from minutecontamination particles.

Applications• Precision metering of very low flow

rates – gases or liquids• Standard for flow or leak rates• Accurate timing in pneumatic or

hydraulic circuits• Flow limiting

Features• High temperature capability

(Type BLP, IBLP)• High pressure capability

(Type BLP)• Bi-directional flow• High accuracy• NIST traceable• Optional in-line screens available

(except Type IBLP)• Orifice calibration available

1/8" NPT

7/16"HEX

.97"

10-32 Straight ThreadSeal

1/4" HEX

Barb for 1/16"ID Plastic Tubing

Type QXLP - 10-32 Bleed Plug

Type IBLP - Insert

.530"

® Registered Trademark of O'Keefe Controls Co.

10-32 Straight Thread

.335"

1/4"HEXSeal

7-1/2°

.250"

.125"

.0945"/.0950" Dia.

Press fits into.0930"/.0940" Dia. Bore

.087"/.089" Dia.

Micro-Orifices®

Size Orifice Air FlowNumber Dia. @ 25 psig

In. sccm

0C .0003 1.240E .0005 3.440G .0007 6.741 .0010 14.0

1E .0015 31.02 .0020 55.0

2E .0025 86.03 .0030 124

3E .0035 1684* .0040 2205* .0050 344

* This size for stainless steel only.See pages 6 through 9 for brass orifices.

KitsSee page 33 for kit selection.

19

Page 19: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

OrificeDiameter (In.) .0003 .0005 .0007 .0010 .0015 .0020 .0025 .0030 .0035 .0040 .0050

Size Number 0C 0E 0G 1 1E 2 2E 3 3E 4 5

Cv .0000019 .0000053 .0000104 .0000216 .0000477 .0000840 .0001300 .0001860 .0002580 .0003490 .0005450

5 0.50 1.38 2.70 5.60 12.4 20.9 33.8 48.2 67.9 90.6 14410 0.72 2.00 3.92 8.13 18.0 31.3 49.4 70.6 97.1 133 20315 0.90 2.51 4.92 10.2 22.2 40.2 62.6 88.7 123 164 25320 1.08 2.99 5.86 12.2 26.7 47.7 74.5 108 146 194 29925 1.24 3.44 6.74 14.0 31.0 55.0 86.0 124 168 220 34430 1.40 3.90 7.64 15.9 35.3 62.1 97.3 141 190 250 39040 1.74 4.83 9.47 19.7 43.8 77.4 123 173 233 309 48250 2.09 5.80 11.4 24.5 53.2 92.1 146 204 278 369 57060 2.42 6.73 13.2 28.4 61.8 107 169 237 324 428 66270 2.76 7.65 15.0 32.5 70.2 121 192 270 369 487 75380 3.09 8.57 16.8 36.5 78.9 135 215 303 415 542 84590 3.45 9.56 18.7 40.7 87.4 153 241 337 461 602 938100 3.80 10.6 20.9 44.8 96.1 168 269 371 504 662 1036

Flow Accuracy ±0.40 ±0.50 ±0.60 ±0.70 ±1.5 ±4 ±6 ±8 ±10 ±20 ±20@ 25 psig SCCM SCCM SCCM SCCM SCCM SCCM SCCM SCCM SCCM SCCM SCCM

General SpecificationsMaximum Operating Pressure –• Type BLP (Brass) 2000 psig• Type BLP (SS) 4000 psig• Types MLP, QXLP 100 psig• Type IBLP (SS) 4000 psig

Body Only

Flow Direction – Suitable for flow in eitherdirection. Data in flow table is measured forthe direction shown in construction draw-ings.

Flow – See chart above for air flow.

Flow Accuracy – See chart above.

Orifice Diameter – .0003" to .0050" (elevenstandard sizes). Consult factory for specialsizes.

Cv Range – .000002 to .000545

Fluid Media – Air, Water, Gases and Liq-uids compatible with materials of construc-tion. Fluids must be free of solid particles,.03 microns or larger.

Materials of Construction –• Type BLP - 303SS or Brass• Type MLP - Brass/Viton gasket• Type QXLP-303SS or Brass/Viton gasket• Type IBLP - 303SS

Custom Orifice SizesCustom orifice sizes, .0003" diameter andlarger, can be produced to exacting airpressure and flow specifications. Usingelectronic pressure and flow measuringequipment that is NIST traceable, the cus-tom Micro-Orifices® are produced to cus-tomer specifications. These custom ori-fices are available in types BLP, MLP,QXLP and IBLP. A certificate of compli-ance to customer specifications is pro-vided for all custom Micro-Orifices®. Con-tact factory for further details.

AccuracyStandard Precision Micro-Orifices® areproduced with very accurate characteris-tics and are production tested at an airsupply pressure of 25 psig. The chart abovelists the nominal flow at 25 psig and theaccuracy of the measured flow for eachorifice size.

CalibrationMeasured air flow data is optionally avail-able. Twenty flow data points, over thespecified supply pressure range, are meas-ured with NIST traceable instruments.

PrecisionPressure Regulator

DigitalMass Flowmeter

Air In

DigitalPressure Gage

Orifice

Flow ToAtmosphere

Sup

ply

Pre

ssur

e —

psi

g

Measurements made@ 70°F ; 29.75" Hg

Above data applies toTypes BLP, MLP, QXLP,IBLP

CONVERSION FACTORS STANDARD CONDITIONS UNITS

SCFH = .00212 X SCCM 68°F (20°C) SCFH = Standard cu. ft. per hr.SLPM = .001 X SCCM 14.7 psia SCCM = Standard cu. cm. per min.

SLPM = Standard liters per min.

TESTPROCEDURE

.0003" to .0050" DIA.

Precision Micro-Orifices®

AIR FLOW — SCCM

® Registered Trademark of O'Keefe Controls Co.

20

Page 20: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

.0003" to .0050" DIA.

DIMENSIONS

Type BLP

Options

Type MLP

Options

Type QXLP Options

CONSTRUCTION

Type BLP Options

Type MLP Options

Type QXLP Options

EXAMPLES1. Type BLP

Orifice .0015" diameterMaterial: Stainless SteelNo OptionsP/N BLP-1E-SS

2. Type BLPOrifice .0010" diameterMaterial: BrassInlet ScreenOutlet ScreenP/N BLP-1-BR/DSO-2-BR/DSO-2-BR

3. Type QXLPOrifice .0007" diameterMaterial: BrassInlet ScreenOutlet ScreenP/N QXSLP-0G-BR/FMS-2-BR

Optional ScreensMicro-Orifices® must be used with ex-tremely clean fluids (filtered to .03 mi-crons). Otherwise, there is a high probabil-ity of clogging the orifice with solid par-ticles. Even with clean fluids, there is alsothe possibility of introducing contaminantsduring assembly of the fluid system. Tominimize the possibility of clogging smallorifices, it is recommended that screens beinstalled on the upstream and downstreamsides of the orifice, to protect against han-dling contamination.

Fifteen micron screens are normally usedwith Micro-Orifices®, to minimize con-tamination that occurs during handling orassembly. Screen material is stainless steel.

Ordering InformationIdentify the part number of Micro-Orifices®

using the complete detail on the chart atright. See examples also.

For orifice assemblies without optionalscreens, use the base number only. Forassemblies that include screens, add thesuffixes shown in the table. Both inlet andoutlet screens are rated for 15 microns.

4. Type MLPOrifice .0035" diameterMaterial: BrassInlet Screen onlyP/N MLP-3E-BR/FMS-2-BR

5. Type QXLPOrifice .0025"Material: Stainless SteelInlet Screen onlyP/N QXLP-2E-SS/FMS-2-SS

6. Type IBLPOrifice .0005" diameterMaterial: Stainless SteelNo OptionsP/N IBLP-0E-SS

10-32 Straight Thread

9/16" HEX

1/8" NPT

7/16"HEX

9/16"HEX

.94"5/16" Round

1/4" HEX Optional InletScreen Assembly

Optional InletScreen Assembly

Optional OutletScreen Assembly

Barb for 1/16"ID Tubing

Precision Micro-Orifices®

OPTIONAL SCREENS

SIZE CHARTSize Orifice

Number Dia.In.

0C .0003

0E .0005

0G .0007

1 .0010

1E .0015

2 .0020

2E .0025

3 .0030

3E .0035

4* .0040

5* .0050

1/4" HEX

5/16" Round

10-32 Straight Thread

.73"

Optional InletScreen Assembly

Optional OutletScreen

2.39"

® Registered Trademark of O'Keefe Controls Co.

*Available SS only. See pages 6 through 9 forBrass.

PART NUMBERS — Micro-Orifices®

INLET OUTLETBODY TYPE SIZE NO. MATERIAL SCREEN SCREENBrass BLP — See Chart — BR / DSO-2-BR / DSO-2-BRSS BLP — See Chart — SS / DSO-2-SS / DSO-2-SS____________________________________________________________________SS IBLP — See Chart — SS / —— ——____________________________________________________________________Brass MLP — See Chart — BR / FMS-2-BR ——____________________________________________________________________Brass QXLP — See Chart — BR / FMS-2-BR *SS QXLP — See Chart — SS / FMS-2-SS *

* Change Type to QXSLP. See example 3 below.** Wire screens are rated 15 microns. Wire is 304SS.

BASE NUMBER OPTIONS**

1/8"NPT

21

Page 21: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Screened Metal Orifices

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

22

INTEGRAL WIRE SCREENS

Type BS or ES

Type BMMS

Type QS

Type QXS

Type US

The complete part number for a screened orifice assembly includes Type, Size Number,and Body Material.

EXAMPLESize Body Part

Type Number Material Number

BS 10 (.010") SS BS-10-SS

QS 4 (.004") Brass QS-4-BR

US 16 (.016") SS US-16-SS

DescriptionStainless steel wire screens are mountedwithin the precision orifice assembly toprotect the orifice from contaminationthat could be introduced during han-dling or installation. The fine screensare not intended to replace normal filtra-tion equipment, but rather to augmentthe protection of small orifices.

ApplicationsThe integral screen/orifice assembly pro-vides a compact arrangement.Type BS and ES – The screen protectsthe orifice from particles in the pressur-ized fluid.Types BMMS, QS, QXS – The screenprotects the orifice from particles thatcould migrate from outside, when thereis no fluid flow.Type US – The dual screen protects theorifices from particles that could enterin either direction.

General SpecificationsMaximum Operating Pressure –Type BS, BMMS, ES

Brass 2000 psig303 SS 4000 psig

Type QS, QXS 100 psigType US (body only) 4000 psigMaximum Differential Pressure – 100 psifor all types.Flow – See flow charts on pages 16 and 17.The screen will cause a decrease of 1 to 2%in flow chart value.Orifice Diameter Accuracy – ±.0003"Cv Range – .00035 to .028See pages 16 and 17.Fluid Media – Air, Water, Gases andLiquids compatible with materials ofconstruction.Dimensions – See drawings on page 23.Screen Material – 304 SS

Part Numbers

ConstructionOrifice Size

Size Dia. NumberNumber In. Range

4 .00395 .00516 .00597 .00718 .00799 .009110 .010211 .011012 .012213 .013014 .014215 .015016 .01617 .01718 .01819 .01920 .02021 .02122 .02223 .02324 .02425 .02526 .02627 .02728 .02829 .02931 .03132 .03233 .03335 .035

Type BS or ESBrass 4-35303SS 4-35

Type BMMSBrass 4-35303SS 4-35

Type QSBrass 4-35

Type QXS303SS 4-35

Type US303SS 5-35

Flow DirectionMetal Orifice Assemblies can be used forflow in either direction. The data onpages 16 and 17 is for a flow direction asshown in the right column on this page.

Screen Filter Ratings

Orifice MicronSize No. Rating4 - 10 1511 - 16 2517 - 35 100

Page 22: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

INTEGRAL WIRE SCREENS

Screened Metal OrificesSpecificationsDimensions

HEX NIPPLEBody and Orifice – Brass or SSThreads – 1/8" or 1/4" NPTStandard Orifice Sizes – .004" to .035" Dia.

BLEED PLUGBody and Orifice – Brass or SSThread – 1/8" NPTStandard Orifice Sizes – .004" to .035" Dia.

BLEED PLUGBody and Orifice – BrassThread – 10-32 UNFThread Seal – VitonStandard Orifice Sizes – .004" to .035" Dia.

BLEED PLUGBody and Orifice – 303 SSThread – 10-32 UNFThread Seal – VitonStandard Orifice Sizes – .004" to .035" Dia.

DUAL SCREEN INSERTBody and Orifice – 303 SSScreen – 304 SSPress Fit Dimension –

Press into bore .2795"/.2805" Dia.Standard Orifice Sizes – .005" to .035" Dia.

Type BS or ES

Type BMMS

Type QS

Type QXS

Type US

23

1/8" NPT

.650"

7/16" HEX

Screen

Type Dim. L HEX NPTBS .970" 7/16" 1/8"ES 1.38" 9/16" 1/4"

1/4"HEX

NPT

10-32 StraightThread

.280"

Seal

Screen

Seal

1/4" HEX7-1/2°

.310"

Screen

10-32 StraightThread

Screen Both Ends

.230"

.2815"/.2825" Dia.

HEX

L

NPT - Both Ends

Screen

Page 23: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Screened Metal Orifices

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

24

INTEGRAL WIRE SCREENS

Type BFSS

Type DS, GS

Type FFOS

Type FMOS

Type IAS

Type ODS

The complete part number for a screened orifice assembly includes Type, Size Number,and Body Material.

EXAMPLESize Body Part

Type Number Material Number

BFSS 10 (.010") Brass BFSS-10-BR

GS 4 (.004") SS GS-4-SS

IAS 16 (.016") Brass IAS-16-BR

DescriptionStainless steel wire screens are mountedwithin the precision orifice assembly toprotect the orifice from contaminationthat could be introduced during han-dling or installation. The fine screensare not intended to replace normal filtra-tion equipment, but rather to augmentthe protection of small orifices.

ApplicationsThe integral screen/orifice assembly pro-vides a compact arrangement.

All types on this pageThe screen is located upstream of theorifice and protects against particlescarried by the pressureized fluid.

For protection against contamination inreverse flow situations add an externalscreen downstream of the orifice.

General SpecificationsMaximum Operating Pressure –See page 25.Maximum Differential Pressure AcrossScreen – 100 psi.Flow – See flow charts on pages 16 and 17.The screen will cause a decrease of 1 to 2%in flow chart value.Orifice Diameter Accuracy – ±.0003"Cv Range – .00035 to .028See pages 16 and 17.Fluid Media – Air, Water, Gases andLiquids compatible with materials ofconstruction.Dimensions – See drawings on page 25.Screen Material – 304 SS

Part Numbers

ConstructionOrifice Size

Size Dia. NumberNumber In. Range

4 .00395 .00516 .00597 .00718 .00799 .009110 .010211 .011012 .012213 .013014 .014215 .015016 .01617 .01718 .01819 .01920 .02021 .02122 .02223 .02324 .02425 .02526 .02627 .02728 .02829 .02931 .03132 .03233 .03335 .035

4-35

All Types

BFSS

DS

FFOS

FMOS

GS

IAS

ODS

Flow DirectionMetal Orifice Assemblies can be used forflow in either direction. The data onpages 16 and 17 is for a flow direction asshown in the right column on this page.

Screen Filter Ratings

Orifice MicronSize No. Rating4 - 10 1511 - 16 2517 - 35 100

Page 24: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

INTEGRAL WIRE SCREENS

Screened Metal Orifices

SpecificationsDimensions

SAE 45° FLARE ADAPTERBody and Orifice – BrassMaximum Operating Pressure – 2000 psigStandard Orifice Sizes – .004" to .035" Dia.

ADAPTERBody and Orifice – Brass or SSMinimum Operating Pressure

Brass Body – 2000 psigSS Body – 4000 psig

Standard Orifice Sizes – .004" to .035" Dia.

COUPLERBody and Orifice – Brass or SSMaximum Operating Pressure – 100 psigStandard Orifice Sizes – .004" to .035" Dia.

ADAPTERBody and Orifice – Brass or SSMaximum Operating Pressure – 100 psigSeal – VitonStandard Orifice Sizes – .004" to .035" Dia.

INSERTBody and Orifice – BrassMaximum Operating Pressure – 2000 psigStandard Orifice Sizes – .004" to .035" Dia.

O-RING ADAPTERBody and Orifice – BrassMaximum Operating Pressure – 2000 psigSeal – VitonStandard Orifice Sizes – .004" to .035" Dia.

Type BFSS

Type DS, GS

Type FFOS

Type FMOS

Type IAS

Type ODS

25

NPT

L

HEX

NPT

Press Fit Into .256"/.257" Dia.

.156"

.258"/.259" Dia.

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Type Dim. L HEX NPTDS .88" 9/16" 1/8"GS 1.25" 3/4" 1/4"

1/8"NPT

1.04"

7/16" HEX

.50".15"

#4 SAE 45° Flare7/16" • 20 Thd

.570"

.312" Dia.

Round

10-32 Thread 10-32 Thread

.312" Dia.

.510"

Round

10-32Thread

10-32Thread

9/16" - 18 UNF Thread5/8" HEX

1/8" NPT

.25" O-Ring

.75"

Page 25: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Screened Sapphire Orifices

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

26

INTEGRAL WIRE SCREENS

Type BTFS

Type BWFS

Type JSS

The complete part number for a screened orifice assembly includes Type, Size Number,and Body Material.

EXAMPLESize Body Part

Type Number Material Number

BTFS 4 (.0016") Brass BTFS-4-BR

BWFS 10 (.0039") SS BWFS-10-SS

JSS 52 (.0205") Brass JSS-52-BR

DescriptionStainless steel wire screens are mountedwithin the precision orifice assembly toprotect the orifice from contaminationthat could be introduced during han-dling or installation. The fine screensare not intended to replace normal filtra-tion equipment, but rather to augmentthe protection of small orifices.

ApplicationsThe integral screen/orifice assemblyprovides a compact arrangement.

Type BTFS and BWFS – The screen islocated upstream of the orifice andprotects against particles carried by thepressurized fluid.

For protection against contamination inreverse flow situations add an externalscreen downstream of the orifice.

Type JSS – The dual screen protects theorifice from particles that could enter ineither direction.

General SpecificationsMaximum Operating Pressure – 100 psigMaximum Differential Pressure Across Screen – 100 psiFlow – See flow charts on page 18. The screen will cause a decrease of 1 to 2% in flow chart value.Orifice Diameter Accuracy – ±.0003"Cv Range – .000030 to .013 See page 18.Fluid Media – Air, Water, Gases andLiquids compatible with materials ofconstruction.Dimensions – See drawings on page 27.Screen Material – 304 SS Part Numbers

ConstructionOrifice Size

Size Dia. NumberNumber In. Range

3 .00124 .00165 .00206 .00247 .00288 .00319 .003510 .003911 .004312 .004713 .005114 .005515 .005916 .006317 .006718 .007120 .007922 .008724 .009426 .010228 .011030 .011832 .012634 .013436 .014240 .015744 .017348 .018952 .020554 .021358 .022864 .0252

3-64

Types

BTFS

BWFS

JSS

Flow DirectionThere is a preferred flow direction forsapphire orifice assemblies. See construc-tion drawings at right.

Screen Filter Ratings

Orifice MicronSize No. Rating3 - 26 1528 - 40 2544 - 64 100

Page 26: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

INTEGRAL WIRE SCREENS

Screened Sapphire Orifices 27

SpecificationsDimensionsADAPTER

Materials Body – Brass or SS Orifice – Sapphire/Nylon SleeveMaximum Operating Pressure – 100 psigOrifice Sizes – .0012" to .0252" Dia.Connections – 1/8" NPT x 1/16" Barb

ADAPTERMaterials Body – Brass or SS Orifice – Sapphire/Nylon SleeveMaximum Operating Pressure – 100 psigOrifice Sizes – .0012" to .0252" Dia.Connections – 1/8" NPT x 1/8" Barb

HEX NIPPLEMaterials Body – Brass or SS Orifice – Sapphire/Nylon SleeveMaximum Operating Pressure – 100 psigOrifice Sizes – .0012" to .0252" Dia.Connections – 1/8" NPT

FLOW METERING

Restriction Orifice Unions

SpecificationsMaterials Orifice Plate – 316 Stainless Steel Union – A105 Carbon Steel or 316 SSSizes – 1/4", 3/8", 1/2", 3/4", 1", 1-1/4", 1-1/2", 2"Connections – NPT or Socket WeldPressure Rating Carbon Steel – 3000 psi Stainless Steel – 3000 psi

Ordering InformationIf orifice size is known provide• Orifice size, connection size, union

material and connection typeIf orifice size is unknown provide• Connection size, union material and

connection type• All of the following data

– fluid type– fluid supply pressure and temperature– pressure differential across orifice– required flow rate– pipe ID

Extra plates – To order plates only, providethe same information as required above.

DescriptionRestriction unions contain an easilyreplaceable orifice plate and are availablein carbon steel or stainless steel. Theassembly is used in liquid or gas pipingsystems to meter flow rate of the fluid. Theall metal assembly is capable of a widerange of pressure and temperaturevariables.

ApplicationsRestriction orifice unions are used in set-ting flow rates of a wide variety of fluids.• Compressed Air• Water• Steam• Hydraulic Fluids• Gases• Chemicals• CoolantsFlow rates can be easily changed by insert-ing other replaceable metering plates.

7/16" HEX

.970"

1/8" NPT - Both Ends

1/8" NPT9/16" HEX

.940"

Barb for 1/8"ID Tubing

Barb for1/16" IDTubing

.875"1/8" NPT

7/16" HEXType BTFS

Type BWFS

Type JSS

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Restriction Orifice Unionhas SS plate with precision

metering orifice.

Restriction Orifice Unionsare threaded or socket weld.

Page 27: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Miniature In-Line Screens28

ApplicationsIn-line screens are suitable for use withliquids or gases compatible with the mat-erials of construction. The screens pro-tect critical components such as orificesfrom clogging or reducing flow rate.Applications for in-line screens includeprotection of:• Precision Orifices• Pneumatic Transducers• Gas and Liquid Flow Instruments• Medical Devices• Filling and Purging Systems• Pneumatic Timers• Transmitters• Pneumatic Transmission Lines• Hydraulic Controls• Leak Test Equipment• Flow Measurement Devices

DescriptionFine screens are used to protect orificesand other critical components from theoccasional particles that enter the fluidduring installation or otherwise. They arenot intended to replace normal filtrationequipment, but rather to augment the pro-tection of critical components in fluid con-trol systems.

Four sizes of screen particle retention areoffered; 10, 15, 25 and 100 microns. Thestainless steel wire screens do not intro-duce loose particles into the fluid stream.The screens are thoroughly cleaned toprevent inadvertent introduction of con-taminants.

FeaturesThe in-line screen products are all metal;the screen material is made from finestainless steel wire.

• Particle retention size as small as 10microns

• Miniature fittings and screens• Clean assemblies• No loose fibers or particles• Long life screen material• Well defined flow characteristics• Compatible with standard 10-32 and

NPT fittings

Type D W ASSA .211" .030" .10"SSB .254" .030" .15"SSC .312" .030" .22"

Screen

10-32 Female ThreadBoth EndsType

FFS

TypeFMS

Type L Hex NPTDSO .880" 9/16" 1/8"GSO 1.250" 3/4" 1/4"

TypesDSOGSO

TypesSSASSBSSC

SS WIRE SCREENS

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

10-32 Female Thread

Screen10-32 Male Thread

.312" Dia.

Round

.560"

NPT NPT

LHEX

MaleNPT

FemaleNPT

Screen

.312" Dia.

.500"

Round

TypesXSAXSBXSCXSD

WD

A

A

Type D WXSA .211" .005"/.010"XSB .254" .005"/.010"XSC .312" .005"/.010"XSD .165" .005"/.010"

W

D

Page 28: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Particle Retention Body Material – Brass Body Material – SS

Type FFS Type FMS Type DSO Type GSO Type FFS Type FMS Type DSO Type GSO Micron Inch 10-32 10-32 1/8" NPT 1/4" NPT 10-32 10-32 1/8" NPT 1/4" NPT

Thread Thread Thread Thread

10 .0004 FFS-1-BR FMS-1-BR DSO-1-BR GSO-1-BR FFS-1-SS FMS-1-SS DSO-1-SS GSO-1-SS

15 .0006 FFS-2-BR FMS-2-BR DSO-2-BR GSO-2-BR FFS-2-SS FMS-2-SS DSO-2-SS GSO-2-SS

25 .0010 FFS-5-BR FMS-5-BR DSO-5-BR GSO-5-BR FFS-5-SS FMS-5-SS DSO-5-SS GSO-5-SS

100 .0040 FFS-20-BR FMS-20-BR DSO-20-BR GSO-20-BR FFS-20-SS FMS-20-SS DSO-20-SS GSO-20-SS

10-32 10-32 1/8" NPT 1/4" NPT 10-32 10-32 1/8" NPT 1/4" NPT

Thread Thread Thread Thread

Configuration

Part Numbers – Screen Fittings

Recommended Screen/Orifice SizingChart Shows Maximum Orifice Diameter (inch)1

Part Numbers – ScreensBound or Plain Types

Ordering Information• Select the part number of the in-line screen fitting or bound screen

from the charts above.• Indicate quantity required.

1. When used with precision orifices, it is important that the screen not havea major influence on the flow through the orifice. The recommendedmaximum orifice when used with a screen will have less than 1% changein the orifice flow.

* MOD – Maximum Orifice Diameter (Inch)

* * Do not use this screen for liquid flow.

Specifications• Body Materials – Brass or 303SS

– Viton Seal on Type FMS• Screen Material – 304SS• Maximum Operating Pressure

– Brass (NPT) – 2000 psig– 304SS (NPT) – 4000 psig– 10-32 Threads – 100 psig

• Maximum Pressure DifferentialAcross Screen – 100 psig

• Flow – See Cv in chart above• Fluids – Use with liquids or gases compatible

with materials of construction• Dimensions – See drawings on page 28

SS WIRE SCREENS

Miniature In-Line Screens

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

29

Particle Retention Types FFS, FMS, DSO Type GSO

Gas Liquid Screen Gas Liquid ScreenMicron Inch Flow Flow C v Flow Flow Cv

MOD* MOD* MOD* MOD*

10 .0004 .0064 * * .009 .011 * * .028

15 .0006 .0105 * * .025 .018 * * .068

25 .0010 .0165 * * .055 .028 * * .180

100 .0040 .0195 .0195 .090 .033 .033 .250

Type Type Type Type

SSA SSB SSC

XSA XSB XSC XSD

SSA-1 SSB-1 SSC-1 —

XSA-1 XSB-1 XSC-1 XSD-1

SSA-2 SSB-2 SSC-2 —

XSA-2 XSB-2 XSC-2 XSD-2

SSA-5 SSB-5 SSC-5 —

XSA-5 XSB-5 XSC-5 XSD-5

SSA-20 SSB-20 SSC-20 —

XSA-20 XSB-20 XSC-20 XSD-20

Particle Retention

Micron Inch

10 .0004

15 .0006

25 .0010

100 .0040

Page 29: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

1/4" HEX

.310"

10-32 Male Thread

Seal

Screen

Filter Rating Connection Part Number Flow(Microns) Size Brass Stainless Steel Cv

15 10-32 QSB-2-BR QSB-2-SS .025

25 10-32 QSB-5-BR QSB-5-SS .055

100 10-32 QSB-20-BR QSB-20-SS .090

15 1/8" NPT BMB-2-BR BMB-2-SS .025

25 1/8" NPT BMB-5-BR BMB-5-SS .055

100 1/8" NPT BMB-20-BR BMB-20-SS .090

15 1/4" NPT EMB-2-BR EMB-2-SS .068

25 1/4" NPT EMB-5-BR EMB-5-SS .180

100 1/4" NPT EMB-20-BR EMB-20-SS .250

TypeBMB

TypeEMB

TypeQSB

.900"

9/16" HEX 1/4" NPT

Screen

7/16" HEX

.650"

1/8" NPT

Screen

DescriptionFine screen breathers provide an air pas-sage into equipment, enclosures, and pneu-matic controls while preventing the inges-tion of solid particles. Miniature finescreen breathers are rated at 15, 25 or 100microns and are available in either brassor stainless steel fittings. Connection sizesare 10-32, 1/8" or 1/4" NPT.

ApplicationsThe fine screen breathers are used wherethere is a requirement to insure that onlyclean fluid enters into a component orsystem. Typical applications include:

• Equipment enclosures

• Vented control components

• Small 3- or 4-way valves

• Small 2-way vacuum valves

• Air purge equipment

• EMI or RFI shield

Specifications• Materials

Body – Brass or 303 SSScreen – 304 SSSeals – Viton (10-32 only)

• Maximum Operating PressureBrass (NPT) – 2000 psig303 SS (NPT) – 4000 psig10-32 threads – 100 psig

• Maximum Pressure DifferentialAcross Screen – 100 psi

• Flow – See Cv data in chart at right.

• Fluids – Use with liquids or gases com-patible with materials of construction.

• Dimensions – See drawings this page.

Ordering Information• Select the part number from the chart

at right.

• Indicate quantity and part number onorder.

Part Numbers – Breathers

SS WIRE SCREENS

Breathers30

Page 30: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

NPT CONNECTIONS

Pressure Snubbers

DescriptionA simple in-line element called a pressuresnubber is used to reduce the rate of flowof fluids into pressure instruments and con-trols. A small orifice in an adapter fittingdampens shock and fluctuating pressureeffects by limiting the rate at which flowenters. The smaller the orifice, the greateris the dampening effect.

The proper orifice size for any applicationdepends upon the size of the pressurizedchamber, the viscosity of the fluid and therequired response time of the system.

Orifice sizes from .004" diameter to .020"diameter are available. In general, largeinstrument chambers require large floworifices. Viscous fluids require larger floworifices than low viscosity fluids. Gasesgenerally require small orifices.

Specifications• Maximum Operating Pressure

Brass – 2000 psig303SS – 4000 psig

• Flow Direction – Suitable for flow ineither direction

• Orifice Diameter – Standard .004",.008", .015", .020". See chart at right.Special orifice sizes available; consultfactory.

• Flow Rate –Air Flow to

Orifice Atmos. @Diameter (in.) CV 25 psig inlet

.004 .00035 .46 scfh

.008 .0015 2.0 scfh

.015 .0050 6.9 scfh

.020 .0088 13.0 scfh

• Fluid Media – Air, Water Gases andLiquids compatible with materials ofconstruction.

Dimensions

ApplicationsPressure snubbers are used as in-line ele-ments to reduce rapid pressure fluctuationsin the following types of components:

• Pressure Gages

• Pressure Measuring Instruments

• Air Piloted Valves

• Hydraulic Piloted Valves

They can also be used to control the flowrate of fluid delivered to:

• Air Cylinders

• Hydraulic Cylinders

• Fluid Actuators

See illustrations for typical applications.

A pressure gage equipped with a snubber willrespond more slowly to pressure changes than agage without a snubber. This slowed responsedampens pressure spikes caused by valves andpumps.

When valve opens the pressure in the pilot portincreases slowly. In the case of an air loadedpressure regulator with a snubber, the output alsoincreases gradually rather than suddenly.

Pressure measuring instruments are protectedfrom surges when equipped with a snubber. Highfrequency pressure spikes are dampened by thesmall orifice in the pressure snubber.

Ordering InformationTo order pressure snubbers, indicate quan-tity and obtain part number from the chart.

Pressure snubber adapts to pressure gage, instru-ment or control element with 1/8", 1/4" or 1/2"NPT connection.

After a valve opens, the pressure in an instrumentor control device builds more slowly whenequipped with a pressure snubber.

Operation

Pressure snubbers are in-line components whichreduce the rate of fluid flow to a gage, instrumentor control element and thus dampen shock andfluctuating pressure effects.

Construction

Part Numbers

Without Snubber

With Snubber

Increasing

PressureIn

Instrument

ValveOpens Time

Increasing

➝➝➝➝ ➝

➝➝➝➝➝

➝➝➝➝➝

➝➝ ➝➝➝

➝➝➝➝➝

Pressure Gage

Snubber

➝➝➝➝➝

Materials• Brass• 303 Stainless Steel

Orifice ➝➝➝➝➝

Female PipeThread

Male Pipe Thread➝➝➝➝➝

➝➝➝➝➝

Orifice Pipe Stainless Steel BrassTYPE Diameter-In. Size (NPT) Part Number Part Number

DP .004 1/8 DP-4-SS DP-4-BRDP .008 1/8 DP-8-SS DP-8-BRDP .015 1/8 DP-15-SS DP-15-BR

GP .004 1/4 GP-4-SS GP-4-BRGP .008 1/4 GP-8-SS GP-8-BRGP .015 1/4 GP-15-SS GP-15-BR

HP .004 1/2 HP-4-SS HP-4-BRHP .008 1/2 HP-8-SS HP-8-BRHP .015 1/2 HP-15-SS HP-15-BRHP .020 1/2 HP-20-SS HP-20-BR

Type T 1 (NPT) T2 (NPT) H-in. L-in.DP 1/8 1/8 9/16 .880GP 1/4 1/4 3/4 1.250HP 1/2 1/2 1-1/16 1.690

Pressure Gage

Pressure Snubber

To Use Point

Valve

➝➝➝➝➝

➝➝➝➝➝

Snubber

Air PilotedValve or

Regulator

Valve

➝➝➝➝ ➝

Valve

➝➝➝➝ ➝

PressureInstrument

To Use Point

➝➝➝➝➝

Snubber

L

T2

H (Across Flats)T1

31

Page 31: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Metal OrificesKit Reference Orifice

Type Part Number Catalog Page Body Material Quantity Diameters

KB-58-BR 8 Brass 58 (1 each) .004" to .125"

KB-174-BR 8 Brass 174 (3 each) .004" to .125"

KB-56-SS 8 303SS 56 (1 each) .006" to .125"

KB-168-SS 8 303SS 168 (3 each) .006" to .125"

KBT-30-BR 6 Brass 30 (1 each) .004" to .035"

KBT-90-BR 6 Brass 90 (3 each) .004" to .035"

KBW-42-BR 6 Brass 42 (1 each) .004" to .063"

KBW-126-BR 6 Brass 126 (3 each) .004" to .063"

KBW-40-SS 6 303SS 40 (1 each) .006" to .063"

KBW-120-SS 6 303SS 120 (3 each) .006" to .063"

KD-58-BR 8 Brass 58 (1 each) .004" to .125"

KD-174-BR 8 Brass 174 (3 each) .004" to .125"

KD-56-SS 8 303SS 56 (1 each) .006" to .125"

KD-168-SS 8 303SS 168 (3 each) .006" to .125"

KM-30-BR 6 Brass 30 (1 each) .004" to .035"

KM-90-BR 6 Brass 90 (3 each) .004" to .035"

KN-42-BR 6 Brass 42 (1 each) .004" to .063"

KN-126-BR 6 Brass 126 (3 each) .004" to .063"

KQX-30-BR 6 Brass 30 (1 each) .004" to .035"

KQX-90-BR 6 Brass 90 (3 each) .004" to .035"

KQX-28-SS 6 303SS 28 (1 each) .006" to .035"

KQX-84-SS 6 303SS 84 (3 each) .006" to .035"

KT-30-BR 6 Brass 30 (1 each) .004" to .035"

KT-90-BR 6 Brass 90 (3 each) .004" to .035"

KT-28-SS 6 303SS 28 (1 each) .006" to .035"

KT-84-SS 6 303SS 84 (3 each) .006" to .035"

KW-42-BR 6 Brass 42 (1 each) .004" to .063"

KW-126-BR 6 Brass 126 (3 each) .004" to .063"

KW-40-SS 6 303SS 40 (1 each) .006" to .063"

KW-120-SS 6 303SS 120 (3 each) .006" to .063"

BT

BW

D

N

M

QX

W

T

METAL

Orifice Kits

DescriptionFor research and development of productsrequiring flow metering, it is convenientto have an accurate array of precision ori-fices. The kits described on this page pro-vide a wide range of orifice sizes and acorresponding wide range of metered flow.

Metal orifice and sapphire orifice kits usecompartmented plastic boxes for storageof the precision restrictors.

The Micro-Orifices® provided in kits in-clude protective screens to protect againstcontamination during handling and instal-lation.

Kit contains anassortment of orifice sizes of one type.

B

® Registered Trademark of O'Keefe Controls Co.

32

Page 32: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Micro-Orifices®

KBLPS-9-BR 19 Brass 9 (1 each) .0003" to .0035"

KBLPS-11-SS 19 303SS 11 (1 each) .0003" to .005"

KMLPS-9-BR 19 Brass 9 (1 each) .0003" to .0035"

KQXSLP-9-BR 19 Brass 9 (1 each) .0003" to .0035"

KQXSLP-11-SS 19 303SS 11 (1 each) .0003" to .005"

KA-96-NY 4 Nylon 96 (3 each) .0012" to .0252"

KF-96-NY 4 Nylon 96 (3 each) .0012" to .0252"

KJ-96-BR 4 Brass 96 (3 each) .0012" to .0252"

KJ-96-SS 4 303SS 96 (3 each) .0012" to .0252"

KL-96-BR 4 Brass 96 (3 each) .0012" to .0252"

KL-96-BR-EN 4 Brass (Plated) 96 (3 each) .0012" to .0252"

KP-96-BR 4 Brass 96 (3 each) .0012" to .0252"

KS-96-BR 4 Brass 96 (3 each) .0012" to .0252"

KS-96-BR-EN 4 Brass (Plated) 96 (3 each) .0012" to .0252"

A

F

J

L

P

S

BLP

MLP

QXLP

SAPPHIRE AND MICRO

Orifice Kits

Sapphire OrificesKit Reference Orifice

Type Part Number Catalog Page Body Material Quantity Diameters

® Registered Trademark of O'Keefe Controls Co.

Special orifice assemblies can be pro-vided where quantity requirements aresufficiently large. Shown to the rightare a few of the custom assemblies pro-duced using sapphire or metal orifices.

Oftentimes sapphire or metal orificescan be press fit into standard threadedor tube fittings. In other cases specialfittings incorporating metal orifices aremachined to order. Integral screens canalso be included in special configura-tions.

Custom Orifice Assemblies

Some of the custom precision orificeassemblies which have previouslybeen manufactured are:

• Modified standard pipe, tube orprocess fittings with orifice inserts.

• Custom machined orifice assem-blies.

• Custom orifices with integralscreen.

• Orifice manifolds for flow selec-tion.

33

Page 33: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

What To Do To ImproveMeasurement AccuracyIn many applications, errors of ±10% inflow rate are unimportant. In this case,corrections for 1) standard conditions, 2)barometric pressure and 3) temperatureare not required.

1. Definition of Standard ConditionsThe data on pages 16-18 is for standardconditions of 70ºF and 14.7 psia. To rec-oncile data taken from volumetric instru-ments which are referenced to differentstandard conditions, use the followingformula:

Qs = Qm x Pm x TS

Qm = measured volumetric flow (SCFH)or (SLPM).

Qs = volumetric flow corrected to 70ºFand 14.7 psia.

Pm = standard barometric pressure refer-enced by manufacturer (psia). This is gen-erally 14.7 psia.

Fundamentals of Flow Measurement

The Standard Cubic Foot

Volumetric FlowThe flow of gases is traditionally measuredin volumetric units such as cubic feet, li-ters or cubic centimeters. However, sincegases are compressible fluids, the totalmass contained in a given volume varieswith both the temperature and pressure ofthe gas. To provide a meaningful referencefor volumetric flow measurements, a"standard" set of conditions are defined fortemperature and pressure of the gas.

Unfortunately, the definition of standardconditions varies slightly in technicaldisciplines and industry groups. Standardtemperature ranges from 32 to 70ºF (0 to20ºC). Standard pressure is generallyaverage atmospheric pressure at sea-level,14.7 psia.

Standard ConditionsFor the data presented in the charts onpages 16-18, standard conditions are 70°Fand 14.7 psia. For data points measuredby O'Keefe Controls Co., the same stan-dard conditions are used.

GAS FLOW MEASUREMENT

A mass flowmeter measures flow accurately andrelatively independent of barometric pressure.The unit shown above is used to obtain the data forcalibrated orifices.

Factors to ConsiderIn comparing volumetric flow measure-ments taken at different locations andwith different measuring equipment,the following factors should be consid-ered:

• Definition of Standard ConditionsBetween 32ºF and 70ºF, the standardconditions can vary up to 8%.

• Temperature of the GasA 10ºF deviation causes about 1%error in a rotameter reading. Moreor less deviation occurs in other typeflow measuring instruments. The de-viations are predictable and the flowmeasurement is correctable.

• Barometric PressureNormal atmospheric pressure varia-tions of ±1/2" Hg. can cause morethan 1% error in rotameters. Altitudeis also an important factor, since thebarometric pressure decreases rap-idly with increasing altitude. At anelevation of 2,000 ft. above sea level,rotameter scale readings are in errorby 3-1/2%. These errors can be cor-rected quite easily with predictablecorrection factors, and accurateknowledge of barometric pressure.

14.7 492

Ps = standard barometric pressure = 14.7 psia.Tm = Standard absolute temperature refer-enced by manufacturer (ºRankine).Ts = standard absolute temperature = 530ºR.For Example:A mass flowmeter manufacturer uses thefollowing standard conditions:14.7 psia, 32°F (492°R)To convert to standard conditions of 70ºF(530ºR) and 14.7 psia, apply the following:

QS = Qm x Pm x TS = Qm x 14.7 x 530

= 1.077 Qm

The volumetric flow QS is larger than Qmby 7.7%. Consult the manufacturer of yourflow measuring equipment to insure thatyou know exactly the standard conditionswhich apply to your equipment.

2. Temperature EffectsConsult your instrument manufacturer fortemperature correction factors. There aretwo temperature considerations.1. Effect of ambient temperature on the

flow measuring instrument2. Effect of gas temperature on the flow

measuring instrument

3. Barometric Pressure EffectsConsult your instrument manufacturer forpressure correction factors. There are twopressure considerations.1. Effect of barometric pressure on the

flow measuring instrument2. Effect of gas pressure on the flow mea-

suring instrument

Table of AverageBarometric Pressure

Altitude Barometer AtmosphericAbove Sea Level Reading Pressure

Feet Inches Mercury PSIA0 29.92 14.696

500 29.38 14.431000 28.86 14.161500 28.33 13.912000 27.82 13.662500 27.32 13.413000 26.82 13.173500 26.33 12.934000 25.84 12.694500 25.37 12.465000 24.90 12.235500 23.99 11.787000 23.10 11.348000 22.23 10.91

PS Tm

PS Tm

34

Page 34: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

4. Other Orifice Sizes Air FlowTo calculate the required diameter of anorifice that is not included in the charts onpages 16-17 use the following formula.The equations are based on data taken forthe size no. 60 (.060" dia.) orifice.

QL dL = .060 Q60

in. dia.

Where:dL = diameter of the unknown orifice.QL = flow through the unknown orifice.Q60 = flow from chart on pages 16-17.

EXAMPLE: (data from page 17)At supply pressure of 50 psig and outlet atstandard conditions,

Q60 = 87.4 SLPM (from chart)Let:QL = 600 SLPM @ 50 psig

600 dL = .060 87.4

= .157 in. dia.

Water FlowUsing the CV method for liquid flow, andusing measured CV data we can derive thefollowing formula to calculate requiredorifice sizes.

1 QL dL =

22.5 ∆P

Where:dL = diameter of unknown orifice (in.)QL = required flow (gpm)

EXAMPLE:Flow rate required =.5 GPM @ ∆P = 1.0 psi

1 .5 dL =

22.5 1 = .149" dia.

Also, to obtain the CV

QL .5

CVL = ∆P = 1

= .5

Low Pressure ExtrapolationTo calculate flow rates at pressures lowerthan those on the charts, use the followingformula.

QLP = Q5 PLP

2 + 29.4 PLP

13.12

QLP = Flow at the low pressure (below 5 psig.)Q5 = Chart flow reading at 5 psig.PLP = Low pressure in psig.

EXAMPLE:To calculate the flow at a supply pressureof 0.5 psig. for the No. 16 metal orifice.

QLP = 3.26 0.52 + 29.4 (.5) = 0.96 SCFH 13.12

(from chart)

3. Temperature Effects Air FlowThe flow of gases through an orifice var-ies inversely as the absolute temperature.As the gas temperature rises and the gasdensity decreases, the mass flow rate alsodecreases.

To extend the chart data on pages 16, 17for air flow, use the following formula.

TS

QT = QS TT

Where:TS = standard absolute temperature °R (°R = 460 + °F).TT = non standard absolute temperature °R.QS = flow from chart at 70°F = 530°R.QT = flow at a different temperature.

EXAMPLE:At 70°F and an inlet pressure of 25 psigthe No. 60 (.060" dia.) orifice has a flowrate of 55 SLPM (see page 17). Undersimilar conditions, the air flow rate at300°F is

530 QT

= 52.8 760 = 44.09 SLPM

1. Specific Gravity Other GasesTo convert air flow from chart to anothergas flow.

Flow (gas) = Flow (air) / S.G. (gas)

EXAMPLE:To obtain flow rate for helium when airflow is 5 SCFH

Flow (Helium) = Flow (air) / .138

= 5 / .371 = 13.48 SCFH

S.G. = specific gravity of gas relative to airS.G. = .138 for Helium

Extending Orifice Flow DataEXTRAPOLATION

2. Pressure – Air Flow High Pressure ExtrapolationTo calculate flow rates at pressures higherthan those on the charts, use the follow-ing formula.

QHP = Q80 x PHP + 14.7

94.7

QHP = Flow at elevated pressure (above 80 psig.).Q80 = Chart flow reading at 80 psig.PHP = Elevated pressure in psig.

EXAMPLE:To calculate the flow for the No. 16 metalorifice at 150 psig supply pressure.

QHP = 17.99 x 150 + 14.7 = 31.15 SCFH 94.7

(from chart)

➞➞➞➞ ➞

➞➞➞➞ ➞

CVL is the CV for the orifice with

diameter = dL.

35

Specific Chart Gas Gravity1 Multiplier2

Air 1.0 1.0Argon 1.379 .852Carbon Dioxide 1.53 .809Helium .138 2.68Hydrogen .0696 3.79Methane .554 1.34Natural Gas .61 1.28Nitrogen .972 1.01Oxygen 1.1053 .95Propane 1.56 .80

Note 1 Specific gravity relative to air @ 70°F, 14.7 psia

Note 2 To obtain the flow of gases other than air,multiply the air flow values on the charts on pages16, 17 and 18 by the chart multiplier.

Page 35: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Conversion FactorsA. Gas Flow

SCFH - standard cu. ft. per hour

SLPM - standard liters per minute

SCCM - standard cu. cm. per minute

SCFH x .472 = SLPM

SCFH x 472 = SCCM

SLPM x 1000 = SCCM

EXAMPLE:

5 SCFH x .472 = 2.36 SLPM

B. Liquid Flow

GPM - gallons per minute

LPM - liters per minute

CCM - cubic centimeters per minute

CFH - cubic feet per hour

CFM - cubic feet per minute

GPM x 3.785 = LPM

GPM x 3785 = CCM

GPM x .1337 = CFM

GPM x 8.021 = CFH

CCM x .001 = LPM

EXAMPLE:

25 GPM x 3.785 = 94.625 LPM

C. Pressure – Gases or Liquids

PSIG - pounds per sq. in. gage

Kg/CM2 - kilograms per sq. cm

KPA - kilo pascals

Bar - unit of pressure equal to 1 atmos.

In-H2O - pressure produced by 1" H2O

PSIG x .0703 = Kg/CM2

PSIG x 6.895 = KPA

PSIG x .0689 = Bars

PSIG x 27.68 = In. H2O

EXAMPLE:

25 psig x 6.895 = 172.37 KPA

Technical ConsiderationsMISCELLANEOUS

Liquid Flow C v MethodA. Water

The Cv method of rating flow capacity ofvarious devices employs empirical databased on water flow. The basic formula forwater flow is

Q = Cv ∆P

Test ProceduresA. Rotameters - Gas Flow

Rotameters for measurement of air or othergas flows must be used for the conditionsfor which they are calibrated. Typically theyare calibrated for the following:

• Air Flow

• Outlet Conditions - 14.7 psig @ 70ºF

Rotameters can be calibrated for other gasflows or other outlet pressure conditions.Manufacturers also provide graphs or tablesfor correction of measured data when con-ditions vary from the calibration conditions.

When using rotameters calibrated for stan-dard outlet conditions use the test proceduresshown below.

Positive Supply Pressure

Vacuum Source

B. Mass Flowmeters - Gas Flow

Mass flowmeters are generally insensitiveto gas pressure or barometric pressure con-ditions. Consequently their location in thetest circuit is not critical. Consult your in-strument manufacturer for recommendedtest procedures.

C. Instrument Accuracy - Gas Flow

The three variables to be measured in gasflow applications are:

• Pressure• Temperature• Flow Rate

The accuracy of the flow measurement of agas through an orifice is limited by the com-bined accuracy of the instruments used inthe measurement. Expected accuracy of agas flow measurement is generally in therange of 1 to 20%. 1% accuracy can only beachieved with high quality instruments.

Specific Gravity of VariousLiquids Relative to Water @ 60ºF

Alcohol, Ethyl .79Gasoline .75Glycerine 1.26Kerosene .80Diesel Oil .85Lube Oil .90Turpentine .87Water 1.00

VacuumGage

ToVacuumSource

OrificeRotameter

AtmosphericInlet

Pressure

Q = flow in GPM

∆P = pressure differential in psi

Cv = flow factor

For a flow of 1 gpm at ∆P = 1, the Cv = 1

To obtain the water flow rate through preci-sion orifices use the above equation and ob-tain the Cv value from the charts on pages16, 17, 18.

EXAMPLE:Size Number 100 (.100" dia.) has a Cv = .23For a 25 psig pressure differential:

Q = Cv ∆ P = .23 25 = 1.15 GPM

B. Other Liquids

For liquids other than water, the equationbecomes:

Q = Cv S.G

Where:

S.G. = Specific gravity of the liquid

(The specific gravity of water is 1.0)

To obtain the flow rate of an oil with S.G. =.85, use the above equation and obtain theCv value from the charts on pages 16, 17, 18.

EXAMPLE: Size number 100 (.100" dia.)has a Cv = .23For a 25 psig pressure differential:

∆ P

Q = Cv ∆ P = .23

25 = 1.25 GPM.85S.G.

AirIn

SupplyPressure

Orifice

ExhaustTo

Atmosphere

Rotameter

36

Page 36: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Calibrated OrificesWATER OR AIR FLOW

Air FlowFor flow standards or other critical uses,O'Keefe Controls Co. can provide measuredair flow data for any of the standard preci-sion orifice products. This optional serviceis available at a nominal charge and can beprovided for pressure or vacuum flow con-ditions in the standard ranges listed below.A calibration sheet with measured data isprovided for each orifice (see sample below).

Data is obtained using a digital mass flow-meter traceable to the National Institute ofStandards Technology (NIST). Standardconditions are 70ºF and 14.7 psia(See photo page 34).

Air flow can be measured for any of thefollowing conditions:

Pressure 0-5, 0-10, 0-20, 0-50, 0-100 psig

Vacuum 0-30" Hg

Flow 0-.002, 0-.01, 0-.02, 0-.05,0-.1, 0-.2, 0-.5, 0-1, 0-2, 0-5,0-10, 0-20, 0-50, 0-200 SLPM

Flow 0-.004, 0-.02, 0-.04, 0-.10,0-.2, 0-.4, 0-1, 0-2, 0-4, 0-10,0-20, 0-40, 0-100, 0-400 SCFH

Water FlowCalibration of standard orifices using wa-ter flow is accomplished by measuring thequantity of water flowing through an ori-fice in a given time period at a specific in-let pressure.

The calibration procedure determines thewater flow rate through the orifice and thecorresponding Cv of the orifice is calcu-lated. The Cv can then be used to predictthe water flow rate at varying differentialpressure conditions using the equation:

Q = Cv ∆P

For liquids other than water flow rate canalso be predicted using the Cv method. Seepage 36 for details on liquid flow - Cvmethod.

A calibration sheet with measured data isprovided for each orifice. The calculated Cvis the average value computed from fiveseparate tests (see sample below).

Cv MeasurementWater at a constant height equivalent to 1 psig isused to determine the amount of water that passesthrough a test orifice in a measured time period.The Cv is calculated from the measured data.

37

Page 37: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Choked Flow of Gases

When the air velocity reaches sonic velocity(P2/P1 ≤ .528) further increases in P1 (upstreampressure) do not cause any further increase inthe air velocity through the orifice. Conse-quently it is wrongly concluded that the massflow rate also does not increase.

As the air pressure (P1) increases, the densityof the air also increases; and since the massflow rate is also a function of density, the massflow rate increases linearly with pressure (P1).

Even though the air velocity through the orifice is limitedto the speed of sound, the mass flow rate continues toincrease as the absolute pressure (P1) increases.

What is Choked?The parameter that becomes “choked” or“limited” is the velocity of the air. It is moreaccurate to use the term “choked velocity”rather than “choked flow” when the absolutepressure ratio of air through an orifice is≤ .528.

Vacuum Conditions

Air at atmospheric pressure enters the orifice and flowsto a downstream vacuum pump.

In the case of vacuum conditions on the outletof an orifice and where the inlet is at ambientatmospheric pressure, both the air velocityand the mass flow rate become choked(limited) when sonic velocity is achievedthrough the orifice.

For atmospheric inlet pressure and downstream vacuum,both the air velocity and mass flow rate are limited.

The Basic ConceptA greatly misunderstood and misappliednotion is that of “choked flow”, also referredto as “critical flow”.

In gas flow through an orifice there is an occa-sion where the gas velocity reaches sonicconditions. This occurs for air flow when theabsolute pressure ratio is .528, i.e. when thedownstream absolute pressure (P2) is 52.8%of the upstream absolute pressure (P1).

Sonic velocity occurs for air flow whenP2

/P1 ≤ .528.

The air flow velocity is limited once the absolutepressure ratio is ≤ .528.

For air flow through an orifice with aninlet air temperature of 68oF the choked(sonic) velocity is 1129 ft/sec.

The Misconception!Once sonic velocity is achieved in orifice airflow (P2/P1 = .528), it is easy to "assume" thatthe mass flow rate is constant for all pressureratios less than .528; i.e. P2/P1 ≤ .528. Forexample, when P2 is 14.7 psia and P1

is 27.84psia, sonic velocity occurs through the orifice.As P

1 further increases there is no further

increase in the velocity of the air flowingthrough the orifice.

Conditions for the onset of sonic velocity in orifice air flow.

Consider all the Factors!The mass flow rate through an orifice is a func-tion of three basic parameters.

Q (flow) is a function of• Velocity• Density• Orifice Area

The reason for the mass flow rate limitation isthe fixed inlet density combined with the fixedvelocity. The flow charts on pages 16-18 showthe choked mass flow effect for vacuum con-ditions. At vacuum levels between 15-30” Hgthe mass flow rate is fixed.

Choked Flow for PositivePressure ConditionsAs in the case of the above vacuum conditionsthere are certain situations in which chokedflow does occur for positive (above atmo-spheric) pressure. By maintaining a fixed in-let pressure to the orifice and allowing theoutlet pressure (back pressure) to vary, thereis a range of outlet pressures over which themass flow rate is fixed.

For example (see chart below).

• With an inlet pressure of 80 psig, the massflow rate is choked (limited) for all outletpressures less than 35.30 psig (includingvacuum conditions).

• The actual flow rate is constant for theoutlet pressure range of 35.30 psig to aslow as a complete vacuum. The flow ratecan be obtained from the charts on pages16-18; e.g. for an orifice of .010" diam-eter and with 80 psig inlet pressure, thechoked flow rate is 8.4 scfh (page 16). Thisflow rate will be constant for all outletpressure conditions between 35.30 psigand full vacuum.

0 1 .528

Sonic Velocity

Mass FlowRate

Air Velocity 0➔➔➔➔➔ 0

MassFlow Rate

➔➔➔➔ ➔ AirVelocity

➔➔➔➔ ➔

Sonic Velocity Conditions – Air Flow Outlet PressureInlet Pressure

For Sonic VelocityGage Absolute Absolute Gage

Pressure Pressure Pressure Pressurepsig psia psia psig100 114.7 ≤ 60.56 ≤ 45.8690 104.7 ≤ 55.28 ≤ 40.5880 94.7 ≤ 50.00 ≤ 35.3070 84.7 ≤ 44.72 ≤ 30.0260 74.7 ≤ 39.44 ≤ 24.7450 64.7 ≤ 34.16 ≤ 19.4640 54.7 ≤ 28.88 ≤ 14.1830 44.7 ≤ 23.60 ≤ 8.9020 34.7 ≤ 18.32 ≤ 3.6215 29.7 ≤ 15.68 ≤ .98

14.7 29.4 ≤ 15.52 ≤ .8210 24.7 ≤ 13.08 ≤ -1.625 19.7 ≤ 10.40 ≤ -4.301 15.7 ≤ 8.29 ≤ -6.470 14.7 ≤ 7.76 ≤ -6.94

Temperature 68°F

P2 = 14.7 psia = 0 psig

P2 /P1 – Absolute Pressure Ratio

0 1 .528

Sonic Velocity1129 ft/sec @

68°F

Choked FlowChoked Velocity

MassFlow Rate

➔➔➔➔ ➔

➔➔➔➔➔ 0

P2 /P1 – Absolute Pressure Ratio

AirVelocity

➔➔➔➔ ➔

P1 = 14.7 psia

P2 < P1Vacuum

P1 = 14.7 psia = 0 psig

StandardAtmosphericConditions

P1 = 27.84 psia = 13.14 psig

P2 = 14.7 psia = 0 psig

Sonic VelocityThrough Orifice

TUTORIAL

0 1 .528

Sonic Velocity1129 ft/sec @

68°F

Air velocity isconstant inthis region

AirVelocity

➔➔➔➔ ➔

➔➔➔➔➔ 0

P2 /P1 – Absolute Pressure Ratio

P1 P2

38

Page 38: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Series 2305

A. B. C.Pipe Size - Overall Height

NPT Length

1/4" 2" 1-1/6"

3/8" 1-3/4" 1-1/16"

1/2" 2-7/32" 1-1/4"

3/4" 2-9/16" 1-17/32"

Series 2307

A. B. C.Pipe Size - Overall Height

NPT Length

3/4" 3-19/32" 2-7/8"

1" 3-19/32" 2-7/8"

1-1/4" 6-3/16" 5-1/4"

1-1/2" 8-7/8" 7-3/8"

SpecificationsMaximum Pressure 150 psig

Constant Flow Pressure Range 15 - 150 psig

Temperature Range 32 to 160o F

Accuracy + 10%

Materials Body - Brass • Diaphragm - Buna-N

ApplicationsWater Flow Rate Control

Heating and Cooling Systems

Water Spray

Film Process and Rinse

Water Conservation

Flow Rate Limitation

Ordering Information• Select the flow rate

• Select the pipe size

• Obtain part number from charts at right

FLOW RATEGPM-H 2O 1/4" NPT 3/8" NPT 1/2" NPT 3/4" NPT

WATER FLOW

Fixed Flow Rate Orifices

0.20 2305-0011-1/40.25 2305-1011-1/40.30 2305-0031-1/4 2305-0031-3/80.40 2305-0041-1/4 2305-0041-3/80.50 2305-1021-1/4 2305-1021-3/8 2305-1021-1/20.60 2305-0061-1/4 2305-0061-3/8 2305-0061-1/20.75 2305-1031-1/4 2305-1031-3/8 2305-1031-1/21.00 2305-1041-1/4 2305-1041-3/8 2305-1041-1/2 2305-1041-3/41.25 2305-1051-1/4 2305-1051-3/8 2305-1051-1/2 2305-1051-3/41.50 2305-1061-1/4 2305-1061-3/8 2305-1061-1/2 2305-1061-3/41.75 2305-1071-1/4 2305-1071-3/8 2305-1071-1/2 2305-1071-3/42.00 2305-1081-1/4 2305-1081-3/8 2305-1081-1/2 2305-1081-3/42.50 2305-1091-1/2 2305-1091-3/43.00 2305-1101-1/2 2305-1101-3/43.50 2305-1111-1/2 2305-1111-3/44.0 2305-1121-1/2 2305-1121-3/44.5 2305-1131-3/45 2305-1141-3/46 2305-1151-3/47 2305-1161-3/48 2305-1171-3/49 2305-1181-3/410 2305-1191-3/4

2305

23073/4", 1" NPT

23071-1/4", 1-1/2" NPT

Part Numbers - Series 2307 8 to 100 GPMFLOW RATE

GPM-H 2O 3/4" NPT 1" NPT 1-1/4" NPT 1-1/2" NPT

PIPE SIZE

8 2307-1171-3/4 2307-1171-19 2307-1181-3/4 2307-1181-110 2307-1191-3/4 2307-1191-111 2307-1201-3/4 2307-1201-112 2307-1211-3/4 2307-1211-113 2307-1221-3/4 2307-1221-114 2307-1231-3/4 2307-1231-115 2307-1241-3/4 2307-1241-116 2307-1251-3/4 2307-1251-117 2307-1261-3/4 2307-1261-118 2307-1271-3/4 2307-1271-1 2307-1271-1-1/419 2307-1281-1 2307-1281-1-1/420 2307-1291-1 2307-1291-1-1/421 2307-1301-1 2307-1301-1-1/422 2307-1311-1 2307-1311-1-1/424 2307-1321-1-1/426 2307-1331-1-1/428 2307-1341-1-1/430 2307-1351-1-1/432 2307-1361-1-1/434 2307-1371-1-1/436 2307-1381-1-1/438 2307-1391-1-1/440 2307-1401-1-1/442 2307-1411-1-1/444 2307-1421-1-1/446 2307-1431-1-1/448 2307-1441-1-1/450 2307-1451-1-1/255 2307-1461-1-1/260 2307-1471-1-1/265 2307-1481-1-1/270 2307-1491-1-1/275 2307-1501-1-1/280 2307-1511-1-1/285 2307-1521-1-1/290 2307-1531-1-1/295 2307-1541-1-1/2100 2307-1551-1-1/2

Dimensions

DescriptionThe fixed flow rate orifices contain adeformable opening which decreases insize as the pressure differential in-creases. The design of the unit compen-sates for pressure differential increaseby reducing the area of the orifice re-sulting in constant flow over the differ-ential pressure range 15-150 psig.

Part Numbers - Series 2305 0.2 to 10 GPM

PIPE SIZE

39

Page 39: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

40

REMOTE READOUT

Water Flow Totalizers

DescriptionThe remote water totalizer system consists of astandard water totalizing meter that is adapted with acontact switch which provides one pulse per gallon;and a remote self powered electronic LCD eight digitdisplay. No external electric power is required.Battery life for the remote register is 10 years.

The meter can be installed in a location not normallyaccessible and the remote readout conveniently locatedfor easy observation. The readout can be up to 1000feet from the flowmeter.

SpecificationsMaximum Pressure – 150 psig

Flow Accuracy + 2% of reading

Readout – Self Powered • 10 year battery life8 digit • 3/8" height

Maximum Temperature Cold Water Meter • 125O FHot Water Meter • 250O F

Meter Body – Bronze

Cable Length – 6 ft. standard– can be extended to 1000 ft.

Remote ReadoutOKC-1319

The remote readout is included with eachtotalizer. It is also available separately.

Remote Readout Only

• Catalog Number OKC-1319

• Operates on remote contact closure

• Self powered internal lithium battery -10 year typical life

• 8 digits – 3/8" height

• Heavy duty enclosure

Remote ReadoutSelf Powered

Flow Totalizerwith Couplings

Catalog Numbers Flow Rate - GPM

Part Number Pipe Size (NPT) Min. Max. Readout

OKC-1317-2 3/4" .25 20 8 digit/gallons

OKC-1317-3 1" .75 50 8 digit/gallons

OKC-1317-4 1-1/2" 1.5 100 8 digit/gallons

OKC-1317-5 2" 2.0 130 8 digit/gallons

OKC-1318-2 3/4" 2 20 8 digit/gallons

OKC-1318-3 1" 4 50 8 digit/gallons

OKC-1318-4 1-1/2" 7 100 8 digit/gallons

OKC-1318-5 2" 9 130 8 digit/gallons

ColdWaterMeter

HotWaterMeter

2-1/4"

5"

Typical Pressure Drop Curve

Pre

ssur

e D

rop

–P

SI

Rate of Flow in Gallons per Minute (GPM)

3/4" 2.5 5 7.5 10 12.5 15 17.5 20 22.5 251" 5 10 15 20 25 30 36 40 45 501-1/2" 10 20 30 40 50 60 70 80 90 1002" 13 25 39 52 65 78 91 104 117 300

Dimensions

3/4" 1" 1-1/2" 2"

A Meter Only

7-1/2" 10-3/4" 12-5/8" 10-5/8"

B

With Couplings (MNPT)12-5/8" 16-1/8" 18-1/2" 16-7/8"

1-3/4"

Page 40: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

DescriptionFor the convenience of interconnecting vari-ous components offered in this catalog, thefollowing accessory items are available.

Polyurethane TubingThe characteristics of polyurethane tubing arevery suitable for use with barb connections. Asecure, long life connection is obtained withthe tubing offered here. Quick-Attach fittingswhich secure to the outside of tubing are alsosuitable with the polyurethane offered here.Consult the factory for color tubing.

Barb FittingsBarb fittings for use with polyurethane tubingprovide economical leak-free connections atpressures up to 100 psig at 70°F. The barb ODis sized to adapt to 1/16" or 1/8" polyurethanetubing.

Threaded FittingsReducing bushings provide a convenient tran-sition from one size to another. The 10-32 cou-pling connects two male threads.

Quick-Attach FittingsRecent new developments in quick attach fit-tings facilitate their use with flexible polyure-thane tubing. The Quick-Attach fittings can beeasily secured to flexible or rigid tubing anddo not require any tools. Secure leak-free at-tachments at pressure up to 100 psig are readilyobtained.

TUBING AND FITTINGS

Accessories

SpecificationsPart No. SizeK150-3 1/16" ID x 1/8" ODK150-4 1/8" ID x 1/4" OD

Color – Clear

TEEPart No. Barb SizeK209-1 1/16"K525-1 1/8"

Material – Brass

THREADED ADAPTERPart No. Barb ThreadK210-1 1/16" 1/8" NPTK211-1 1/16" 10-32K211-2 1/8" 10-32K521-1 1/8" 1/8" NPT

Material – Brass

BARB ADAPTERPart No. SizeKVC1-2 1/8" x 1/16"

Material – Nylon

REDUCING BUSHINGPart No. SizeKMPA-1410 10-32 x 1/4" NPTKMPA-1610 10-32 x 1/16" NPTKMPA-1810 10-32 x 1/8" NPT

Material – Brass

COUPLINGK1046-1 10-32 X 10-32

Material – Brass

MALE CONNECTORPart No. Thread TubeOKQH01-32 10-32 1/8" ODOKQH07-32 10-32 1/4" ODOKQH07-34S 1/8" NPT 1/4" ODOKQH07-35S 1/4" NPT 1/4" OD

Material – Brass/Plastic

UNION TEEPart No. Tube SizeOKQT01-00 1/8" ODOKQT07-00 1/4" OD

Material – Brass/Plastic

BULKHEAD UNIONPart No. Tube SizeOKQE01-00 1/8" ODOKQE07-00 1/4" OD

Material – Brass/Plastic

41

Page 41: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

FLOW METERS

Accessories

In-Line Flowmeters with Pressure Gage – Air ServiceCalibrated for Inlet Pressures 40-100 psig • Vertical or Horizontal ➝➝➝➝➝ Mounting

Pipe Size Flow Range Approximate Inlet MaximumPart No.* Female NPT SCFM to Outlet Dim. HeightOKC-1000-1 1/4" 1-4 6-3/4" 4-1/4"OKC-1000-2 1/4" 2-9 6-3/4" 4-1/4"OKC-1000-3 1/4" 2-18 6-3/4" 4-1/4"OKC-1000-5 1/2" 2-20 9-1/4" 4-3/4"OKC-1000-6 1/2" 10-60 9-1/4" 4-3/4"OKC-1000-10 3/4" 5-50 10-1/2" 5-1/4"OKC-1000-11 3/4" 10-90 10-1/2" 5-1/4"

*Maximum Pressure 150 psig; Maximum Temperature 150°F

In-Line Flowmeters with Pressure Gage – Water ServiceVertical or Horizontal ➝➝➝➝➝ Mounting

Pipe Size Flow Range Approximate Inlet MaximumPart No.* Female NPT GPM to Outlet Dim. HeightOKC-1001-1 1/2" 0.5-4 9-1/8" 5-1/8"OKC-1001-2 1/2" 1-7 9-1/8" 5-1/8"OKC-1001-3 1/2" 1-10 9-1/8" 5-1/8"OKC-1001-4 1/2" 1-16 9-1/8" 5-1/8"OKC-1001-6 3/4" 1-7 9-3/8" 5-1/8"OKC-1001-8 3/4" 1-16 9-3/8" 5-1/8"OKC-1001-10 3/4" 4-28 9-3/8" 5-1/8"OKC-1001-13 1" 1-10 8-3/4" 5-1/8"OKC-1001-15 1" 4-18 8-3/4" 5-1/8"OKC-1001-16 1" 4-28 8-3/4" 5-1/8"

*Maximum Pressure 150 psig; Maximum Temperature 150°F

Flowmeters – Air Service – Rotameter StyleCalibrated for Standard Atmospheric Conditions • Vertical Mounting Only

Air Flow Range Dimensions MaximumPart No.* (SCFH) Overall Height Scale Length Connection PressureKRMA-1 .05 - .5 4-9/16" 2" 1/8" NPT 100 psigKRMA-3 .2 - 2 4-9/16" 2" 1/8" NPT 100 psigKRMA-5 1-10 4-9/16" 2" 1/8" NPT 100 psigKRMB-52 5-50 8-1/2" 5" 1/4" NPT 70 psigKRMB-54 20-200 8-1/2" 5" 1/4" NPT 70 psigKRMC-104 40-400 15-1/8" 10" 1/2" NPT 35 psigKRMC-106 100-1000 15-1/8" 10" 1/2" NPT 35 psigKRMC-108 180-1800 15-1/8" 10" 1/2" NPT 35 psig

*Maximum Temperature 130°F

➝➝➝➝ ➝

➝➝➝➝ ➝

➝➝➝➝ ➝

42

Page 42: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Precision Air Pressure Regulators

Part No. Output SupplyPart No.* With Gage Size Pressure (max.) DimensionsOKC-1045-1 OKC-1045-1G 0-2 psigOKC-1045-2 OKC-1045-2G 0-10 psig Inlet toOKC-1045-3 OKC-1045-3G 1/4" 0-20 psig

400 psigOutlet < 3"

OKC-1045-4 OKC-1045-4G NPT 0-30 psigOKC-1045-5 OKC-1045-5G 0-60 psig HeightOKC-1045-6 OKC-1045-6G 0-160 psig 6-1/2" max.

*Maximum Pressure 150 psig; Maximum Temperature 150°F

Fine Air Filters

Connection Micron Dimensions Max. Flow Max.Part No.** Size Rating Drain W H SCFM Pressure*OKC-1379 1/4" NPT 5 Manual 1.5" 3.6" 3 150 psigOKC-1380 1/4" NPT .01 Manual 1.5" 3.6" 3 150 psigOKC-739 1/4" NPT 5 Auto 3.0" 7.5" 10 150 psigOKC-740 1/4" NPT .01 Auto 3.0" 7.5" 10 150 psigOKC-730 1/4" NPT 5 Auto 3.3" 8.2" 20 150 psigOKC-731 1/4" NPT .01 Auto 3.3" 8.2" 20 150 psig

*Maximum Operating Temperature 125°F** Filter Bowls are polycarbonate. Metal bowl guard included.

Low Pressure Air/Electric Switches

Switching Maximum MaximumPart No. Dimensions Connections Pressure Pressure Type Current

Single or 60 ma @Differential 120/60

OKC-819 3/4" x 3/4" x 1" h (2) 1/16" barb 1" H2O 1 psigSP Double 40 ma @

Break 120 VDCOKC-819-1 Normally Open OKC-819-2 Normally Closed

Single or 200 ma @Differential 30 VDC

OKC-661 1-7/8" x 1" x 3/8" h (2) 1/8" barb 1/2" H2O 1 psigSP DoubleNeon Lamp @

(part number KVC1-2 - 1/8" x 1/16" barb reducer) Break 120/60

Single 10 amps @OKC-664 1-9/16" x 2-5/8" (1) 1/16" barb 4" H2O 5 psig SPDT 125 or

x 1-21/32" h 250 VDC

MISCELLANEOUS

Accessories

H

W

43

Page 43: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

BALL TYPE

Check Valves – Fixed Flow Controls44

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

DescriptionBall type check valves are produced inthree sizes: 10-32, 1/8" NPT and 1/4"NPT. They are available in both brassand stainless steel and are suitable foruse with liquids or gases. Free flowoccurs in one direction only; reverseflow is prevented.

Fixed flow controls are a parallelarrangement of a ball check valve and aprecision orifice. Free flow occurs inone direction and metered flow occursin the opposite direction. Suitable forboth liquids and gases the fixed flowcontrols are available in brass orstainless steel.

Features• All metal construction

• Long life operation

• Choice of cracking pressure

• Tamperproof orifice

• High pressure capability

Specifications• Materials of Construction

Body - Brass or 303SSBall Check Assembly - 304SSFlow Control Orifice -

Brass or 303SSSealant - Locite 609

High pressure types only• Temperature - 300°F (max.)

• Standard Pressure Type -NPT - 200 psig (max.)10-32 - 125 psig (max.)

• High Pressure Type (Suffix H) -NPT - 2000 psig (max.)

• Seat Leakage - 20 sccm (max.)air flow at 25 psi differential

• Flow Capacity -Check ValvesFree Flow Direction

Size 10-32 1/8" NPT 1/4" NPTType FFLC BLC, BLCH ELC, ELCHCv .081 .081 .225

Fixed Flow ControlsSee charts on following pagesfor details.

• Check Valve Cracking PressureSelectable 0, 2, 10 or 15 psid

Types ELC and ELF; ELCH and ELFH

Types BLC and BLF; BLCH and BLFH

Types FFLC and FFLF

TYPEBLC, BLCHBLF, BLFHELC, ELCHELF, ELFH

FFLCFFLF

T T

H (Hex)

A

T

B

C (Dia.)

T

TypeStandard HighPressure Pressure Type Type A B C H T

BLC BLCH 0.97 – – 7/16 1/8" NPT

BLF BLFH 1.40 – – 9/16 1/8" NPT

ELC ELCH 1.38 – – 9/16 1/4" NPT

ELF ELFH 1.91 – – 11/16 1/4" NPT

FFLC – – 0.78 3/8 – 10-32

FFLF – – 0.87 7/16 – 10-32

Dim. – in.

Dimensions

Page 44: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

BALL TYPE

Check Valves – Fixed Flow Controls 45

Ordering InformationCHECK VALVE – PART NUMBER

Cracking BodyType Pressure Material Part NumberFFLC 2 BR FFLC-2-BR (standard pressure)

Examples BLC 10 SS BLC-10-SS (standard pressure)ELCH 15 BR ELCH-15-BR (high pressure)

FIXED FLOW CONTROL – PART NUMBEROrifice Cracking Body

Type Size No. Pressure Material Part NumberFFLF 10 10 BR FFLF-10-10-BR (standard pressure)

Examples BLFH 25 15 SS BLFH-25-15-SS (high pressure)ELF 60 2 SS ELF-60-2-SS (standard pressure)

*See charts on next page. † High pressure type use suffix H

Air Free Flow Max. Pressure Max.Free Inlet - 100 psig Standard High Cracking LiquidFlow Outlet - atmos. (Suffix H)† Pressure Flow BodyCv scfh* psig psig psid gpm Materials

.084 346 0, 2 .84 Brassto to 125 — or to or

.162 662 10 1.62 SS

.084 346 0, 2 1.2 Brassto to 200 2000 or to or

.162 662 10 2.3 SS

.228 950 0, 2 3.2 Brassto to 200 2000 or to or

.425 1767 15 6 SS

Fixed Flow Control Characteristics

TypeFFLF10-32thread

TypeBLF,BLFH1/8" NPT

TypeELF,ELFH1/4" NPT

Construction

† High pressure type use suffix H

Check Valve CharacteristicsAir Free Flow Max. Pressure Max.

Free Inlet - 100 psig Standard High Cracking LiquidFlow Outlet – atmos. (Suffix H)† Pressure Flow BodyCv scfh psig psig psid gpm Materials

0, 2 Brass.081 331 125 — or .80 or

10 SS

0, 2 Brass.081 331 200 2000 or 1.1 or

10 SS

0, 2 Brass.225 951 200 2000 or 3.2 or

15 SS

TypeFFLC10-32thread

TypeBLC,BLCH1/8" NPT

TypeELC,ELCH1/4" NPT

Construction

Page 45: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

BALL TYPE

Check Valves – Fixed Flow Controls46

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Types BLF, BLFH, FFLFOrifice Cv Ratio

Orifice Size Dia. Orifice Cv Check Valve Assembly Forward CvNumber In. (return) Cv Forward Cv Return Cv

10 .0102 0.0025 0.081 0.084 33.4011 .0110 0.0028 0.081 0.084 29.93

*12 .0122 0.0034 0.081 0.084 24.8213 .0130 0.0038 0.081 0.085 22.3214 .0142 0.0043 0.081 0.085 19.8415 .0150 0.0050 0.081 0.086 17.2016 .016 0.0055 0.081 0.087 15.7317 .017 0.0067 0.081 0.088 13.0918 .018 0.0073 0.081 0.088 12.1019 .019 0.0080 0.081 0.089 11.13

*20 .020 0.0088 0.081 0.090 10.2021 .021 0.0096 0.081 0.091 9.4422 .022 0.011 0.081 0.092 8.3623 .023 0.012 0.081 0.093 7.7524 .024 0.013 0.081 0.094 7.2325 .025 0.014 0.081 0.095 6.79

*26 .026 0.016 0.081 0.097 6.0627 .027 0.017 0.081 0.098 5.7628 .028 0.018 0.081 0.099 5.5029 .029 0.019 0.081 0.100 5.2631 .031 0.022 0.081 0.103 4.68

*32 .032 0.024 0.081 0.105 4.3833 .033 0.025 0.081 0.106 4.2435 .035 0.028 0.081 0.109 3.8937 .037 0.031 0.081 0.112 3.6138 .038 0.032 0.081 0.113 3.5339 .039 0.033 0.081 0.114 3.45

*40 .040 0.036 0.081 0.117 3.2541 .041 0.038 0.081 0.119 3.1342 .042 0.039 0.081 0.120 3.0843 .043 0.041 0.081 0.122 2.9847 .047 0.048 0.081 0.129 2.69

*52 .052 0.059 0.081 0.140 2.3755 .055 0.068 0.081 0.149 2.1960 .060 0.081 0.081 0.162 2.00

Metered Flow – Return Cv

Free Flow – Forward Cv

Fixed Flow Control Symbol

*These sizes are normally stocked with 2 psid cracking pressure.

*These sizes are normally stocked with 2 psid cracking pressure.

Types ELF, ELFHOrifice Cv Ratio

Orifice Size Dia. Orifice Cv Check Valve Assembly Forward CvNumber In. (return) Cv Forward Cv Return Cv

10 .0102 0.0025 0.225 0.228 91.0011 .0110 0.0028 0.225 0.228 81.36

*12 .0122 0.0034 0.225 0.228 67.1813 .0130 0.0038 0.225 0.229 60.2114 .0142 0.0043 0.225 0.229 53.3315 .0150 0.0050 0.225 0.230 46.00

*16 .016 0.0055 0.225 0.231 41.9117 .017 0.0067 0.225 0.232 34.5818 .018 0.0073 0.225 0.232 31.8219 .019 0.0080 0.225 0.233 29.13

*20 .020 0.0088 0.225 0.234 26.5721 .021 0.0096 0.225 0.235 24.4422 .022 0.011 0.225 0.236 21.4523 .023 0.012 0.225 0.237 19.7524 .024 0.013 0.225 0.238 18.3125 .025 0.014 0.225 0.239 17.07

*26 .026 0.016 0.225 0.241 15.0627 .027 0.017 0.225 0.242 14.2428 .028 0.018 0.225 0.243 13.5029 .029 0.019 0.225 0.244 12.8431 .031 0.022 0.225 0.247 11.23

*32 .032 0.024 0.225 0.249 10.3833 .033 0.025 0.225 0.250 10.0035 .035 0.028 0.225 0.253 9.0437 .037 0.031 0.225 0.256 8.2638 .038 0.032 0.225 0.257 8.0339 .039 0.033 0.225 0.258 7.82

*40 .040 0.036 0.225 0.261 7.2541 .041 0.038 0.225 0.263 6.9242 .042 0.039 0.225 0.264 6.7743 .043 0.041 0.225 0.266 6.4947 .047 0.048 0.225 0.273 5.69

*52 .052 0.059 0.225 0.284 4.8155 .055 0.068 0.225 0.293 4.3160 .060 0.081 0.225 0.306 3.7863 .063 0.088 0.225 0.313 3.5667 .067 0.10 0.225 0.325 3.2570 .070 0.11 0.225 0.335 3.0573 .073 0.12 0.225 0.345 2.8876 .076 0.13 0.225 0.355 2.73

*79 .079 0.14 0.225 0.365 2.6181 .081 0.15 0.225 0.375 2.5086 .086 0.17 0.225 0.395 2.3289 .089 0.18 0.225 0.405 2.2594 .094 0.20 0.225 0.425 2.13

FreeFlow

MeteredFlow

Page 46: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

BALL TYPE

Checked Orifices47

DescriptionChecked orifices are a series arrangementof a precision orifice, a ball check valve andan optional screen. The all metal assem-blies are made of brass or stainless steel.Gas or liquid can flow in one direction only,at a rate established by the metering orifice.Reverse pressure differential does notresult in reverse flow. Standard sizes are10-32, 1/8" NPT and 1/4" NPT. Customrequirements will be reviewed for largequantity applications.

Applications• Unidirectional gas or liquid flow• Backflow prevention in

metering systems• Fluid contamination reduction• Isolation of fluid sources in mixers• Fuel line metering with no

reverse flow• Medical metering of fluids

Ordering InformationPart Number System

Type Orifice Cracking MaterialSize No. Pressure

Examples

BIFLC - 10 - 2 - BR(Standard .010" 2 psig BrassPressure)

FIFLCS - 31 - 10 - BR(With .031" 10 psig Brass

Screen)

EIJLCSH - 125 - 15 - SS(High .125" 15 psig Stainless

Pressure SteelWith Screen)

Specifications• Materials of Construction

Body - Brass or 303SSBall Check Assembly - 304SSFlow Control Orifice - Brass or 303SSSealant - Loctite 609

High pressure types only• Temperature - 300°F (max.)• Standard Pressure Type -

NPT - 200 psig (max.)10-32 - 125 psig (max.)

• High Pressure Type (Suffix H) -NPT - 2000 psig (max.)

• Seat Leakage - 20 sccm (max.)air flow at 25 psi differential

• Cracking Pressure -- 10-32 or 1/8" NPT 0, 2 or 10 psig- 1/4" NPT 0, 2 or 15 psig

• Flow Capacity - Cv and air flowshown in chart below

*These sizes are normally stocked with 2 psid cracking pressure.

Orifice OrificeSize Dia. Orifice Air Flow – SCFH

Number In. Cv 25 psig 100 psig10 .0102 0.0025 3.37 9.8111 .0110 0.0028 3.62 10.5

*12 .0122 0.0034 4.66 13.413 .0130 0.0038 5.30 15.314 .0142 0.0043 6.06 17.415 .0150 0.0050 6.95 20.0

*16 .016 0.0055 7.25 21.817 .017 0.0067 8.31 25.018 .018 0.0073 9.43 28.419 .019 0.0080 10.4 31.1

*20 .020 0.0088 11.8 35.221 .021 0.0096 12.7 38.122 .022 0.011 15.5 44.723 .023 0.012 16.8 48.724 .024 0.013 18.3 53.225 .025 0.014 19.9 58.1

*26 .026 0.016 21.6 62.327 .027 0.017 22.7 65.328 .028 0.018 24.8 71.429 .029 0.019 27.1 78.031 .031 0.022 30.1 86.7

*32 .032 0.024 32.6 94.533 .033 0.025 34.5 10135 .035 0.028 37.5 11437 .037 0.031 41.5 12638 .038 0.032 44.1 13539 .039 0.033 47.9 146

*40 .040 0.036 50.9 15641 .041 0.038 52.3 16442 .042 0.039 54.9 16743 .043 0.041 58.5 17747 .047 0.048 67.6 203

*52 .052 0.059 85.4 25455 .055 0.068 94.5 28260 .060 0.081 112 33163 .063 0.088 122 36267 .067 0.10 141 41570 .070 0.11 158 46873 .073 0.12 168 49676 .076 0.13 183 540

*79 .079 0.14 198 58781 .081 0.15 212 62786 .086 0.17 233 69789 .089 0.18 248 73994 .094 0.20 278 831

FO

R

10

/32

, 1

/8"

NP

T

an

d

1/4

" N

PT

1/4

" N

PT

O

NL

Y

1/8" NPTTypesBIFLCBIFLCH*

T TL

Hex

Dimensions

10-32TypeFIFLC

Flow

Check ValveOrifice

Check Valve Orifice

1/4" NPTTypesEIJLCEIJLCH*

10-32TypeFIFLCS

Check Valve OrificeScreen

1/8" NPTTypesBIFLCBIFLCSBIFLCH*BIFLCSH*

1/4" NPTTypesEIJLCEIJLCSEIJLCH*EIJLCSH*

10-32TypesFIFLCFIFLCS 10-32

Thread10-32

Thread

.375"

.780"

Thread (T) Hex L1/8" NPT 7/16" .970"1/4" NPT 9/16" 1.38"

Select – Type from illustrations inright column and fromSPECIFICATIONS

Orifice Size No. from chart

Cracking Pressure fromSPECIFICATIONS

Material - Brass or Stainless Steel

Check Valve/Orifice

Screen/Check Valve/Orifice

*high pressure

*high pressure

1/8" NPTTypesBIFLCSBIFLCSH*

1/4" NPTTypesEIJLCSEIJLCSH*

Flow

Check Valve OrificeScreen

*high pressure

Page 47: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

DISK TYPE

Check Valves – Fixed Flow Controls48

Disk check valves have high flowcapacity and low pressure drop.

Applications• Air Cylinder Speed Controls• Compressed Air Dryer

Purge Controls• Timing Circuits

Features• High Flow Capacity• Low Pressure Loss• Low Cracking Pressure• Long Life Operation• Tamperproof Orifice

Description Disk type check valves are produced inthree sizes: 1/8" NPT, 1/4" NPT and 3/8"NPT. They are available in both brass andstainless steel and are suitable for use withliquids or gases. Free flow occurs in onedirection only; reverse flow is prevented. Fixed flow controls are a parallel ar-rangement of a disk check valve and aprecision orifice. Free flow occurs in onedirection and metered flow occurs in theopposite direction. Suitable for both liquidsand gases the fixed flow controls are avail-able in brass or stainless steel.

Specifications• Maximum Pressure - 150 psig

• Maximum Temperature Brass Disk Assembly - 225°F 303 SS Disk Assembly - 225°F Delrin Disk Assembly - 120°F

• Flow CapacityCheck Valves - Free Flow Direction

Size 1/8" NPT 1/4" NPT 3/8" NPTCv .43 .61 1.09

Fixed Flow Controls - Free Flow Direction

Size 1/8" NPT 1/4" NPT 3/8" NPTCv .43 - .51 .61 - .98 1.09 - 1.46See chart on page 50 for details.

• Materials of ConstructionBody – Brass or 303 SSSeals – VitonDisk – Brass, 303SS or Delrin

• Cracking Pressure –Less than 0.25 psid

• Orifice Sizes (Fixed Flow Controls).004" to .125"

• Seat Leakage (Check Valves)Bubbletight for differentialpressure greater than 2 psid

Type DOC, GOC

Type DOF, GOF

orifice

Type Y2C, Y4C, Y6C

Type Y2F, Y4F, Y6F

orifice

Dimensions

Y2C

Y4C

Y6C

Y2F

Y4F

Y6F

D0C

G0C

D0F

G0F

Type L NPT Hex

D0C 1.720 1/8" 11/16"

G0C 2.110 1/4" 3/4"

D0F 1.720 1/8" 11/16"

G0F 2.110 1/4" 3/4"

Y2C 1.625 1/8" 11/16"

Y4C 2.020 1/4" 3/4"

Y6C 1.945 3/8" 15/16"

Y2F 1.625 1/8" 11/16"

Y4F 2.020 1/4" 3/4"

Y6F 1.945 3/8" 15/16"Dim. In.

LHex

NPT NPT

Hex

L

NPT

Page 48: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Check Valves – Fixed Flow ControlsDISK TYPE

49

Part Number Construction – Fixed Flow ControlsUse delrin disk for air and inert gases

Orifice Body DiskType Size No.* Material Material Part Number

Examples GOF - 10 - SS - SS GOF-10-SS-SS(1/4" male/female) (.010" orifice) (303 SS) (303 SS)

Y6F - 22 - BR - DE Y6F-22-BR-DE(3/8" female/female) (.022" orifice) (Brass) (Delrin)

Part Number Construction – Check ValvesUse delrin disk for air and inert gasesCracking Body Disk

Type Pressure Material Material Part NumberExamples GOC -

0- SS - DE GOC-0-SS-DE

(1/4" male/female) (303 SS) (Delrin)Y6C -

0- BR - BR Y6C-0-BR-BR

(3/8" female/female) (Brass) (Brass)

*See chart on page 50.

Pipe Metering* FreeSize End Orifice Body Disk Maximum Flow

Type Construction NPT Connections Size No. Material Material Pressure Cv

DOF 1/8" male/female 4 to 125 Brass .43 to(BR) .51

GOF 1/4" male/female 4 to 125 Brass 303 SS .61 to(BR) (SS) .98

Y2F 1/8" female/female 4 to 125 or or 150 psig .43 to.51

303 SS DelrinY4F 1/4" female/female 4 to 125 (SS) (DE) .61 to

.98

Y6F 3/8" female/female 4 to 125 1.09 to1.46

Part Number – Fixed Flow Controls

orifice

orifice

*See chart on page 50.

Ordering InformationPart Number – Check Valves

Pipe FreeSize End Cracking Body Disk Maximum Flow

Type Construction NPT Connections Pressure Material Material Pressure Cv

DOC 1/8" male/female Brass(BR) .43

GOC 1/4" male/female Brass 303 SS(BR) (SS) .61

Y2C 1/8" female/female 0 or or 150 psig.43

303 SS DelrinY4C 1/4" female/female (SS) (DE)

.61

Y6C 3/8" female/female1.09

Page 49: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

DISK TYPE

Check Valves – Fixed Flow Controls50

Fixed Flow Control Symbol

Free Flow – Forward Cv

Metered Flow – Return Cv

orifice

Types DOF, Y2F Types GOF, Y4F Type Y6FOrifice Orifice

OrificeCv Ratio Cv Ratio Cv Ratio

Size No. Dia.Cv

Forward Forward Cv Forward Forward Cv Forward Forward Cv(return)Cv Return Cv Cv Return Cv Cv Return Cv

4 .0039 .00035 .430 1229.57 .614 1755.29 1.091 3118.145 .0051 .00061 .431 705.92 .615 1007.56 1.092 1789.526 .0059 .00086 .431 501.00 .615 714.95 1.092 1269.607 .0071 .0012 .431 359.33 .615 512.67 1.092 910.178 .0079 .0015 .432 287.67 .616 410.33 1.093 728.339 .0091 .0019 .432 227.32 .616 324.16 1.093 575.2110 .0102 .0025 .433 173.00 .617 246.60 1.094 437.4011 .0110 .0028 .433 154.57 .617 220.29 1.094 390.6412 .0122 .0034 .433 127.47 .617 181.59 1.094 321.8813 .0130 .0038 .434 114.16 .618 162.58 1.095 288.1114 .0143 .0043 .434 101.00 .618 143.79 1.095 254.7215 .0150 .0050 .435 87.00 .619 123.80 1.096 219.2016 .016 .0055 .436 79.18 .620 112.64 1.097 199.3617 .017 .0067 .437 65.18 .621 92.64 1.098 163.8418 .018 .0073 .437 59.90 .621 85.11 1.098 150.4519 .019 .0080 .438 54.75 .622 77.75 1.099 137.3820 .020 .0088 .439 49.86 .623 70.77 1.100 124.9821 .021 .0096 .440 45.79 .624 64.96 1.101 114.6522 .022 .011 .441 40.09 .625 56.82 1.102 100.1823 .023 .012 .442 36.83 .626 52.17 1.103 91.9224 .024 .013 .443 34.08 .627 48.23 1.104 84.9225 .025 .014 .444 31.71 .628 44.86 1.105 78.9326 .026 .016 .446 27.88 .630 39.38 1.107 69.1927 .027 .017 .447 26.29 .631 37.12 1.108 65.1828 .028 .018 .448 24.89 .632 35.11 1.109 61.6129 .029 .019 .449 23.63 .633 33.32 1.110 58.4231 .031 .022 .452 20.55 .636 28.91 1.113 50.5932 .032 .024 .454 18.92 .638 26.58 1.115 46.4633 .033 .025 .455 18.20 .639 25.56 1.116 44.6435 .035 .028 .458 16.36 .642 22.93 1.119 39.9637 .037 .031 .461 14.87 .645 20.81 1.122 36.1938 .038 .032 .462 14.44 .646 20.19 1.123 35.0939 .039 .033 .463 14.03 .647 19.61 1.124 34.0640 .040 .036 .466 12.94 .650 18.06 1.127 31.3141 .041 .038 .468 12.32 .652 17.16 1.129 29.7142 .042 .039 .469 12.03 .653 16.74 1.130 28.9743 .043 .041 .471 11.49 .655 15.98 1.132 27.6147 .047 .048 .478 9.96 .662 13.79 1.139 23.7352 .052 .059 .489 8.29 .673 11.41 1.150 19.4955 .055 .068 .498 7.32 .682 10.03 1.159 17.0460 .060 .081 .511 6.31 .695 8.58 1.172 14.4763 .063 .088 .518 5.89 .702 7.98 1.179 13.4067 .067 .10 .530 5.30 .714 7.14 1.191 11.9170 .070 .11 .540 4.91 .724 6.58 1.201 10.9273 .073 .12 .550 4.58 .734 6.12 1.211 10.0976 .076 .13 .560 4.31 .744 5.72 1.221 9.3979 .079 .14 .570 4.07 .754 5.39 1.231 8.7981 .081 .15 .580 3.87 .764 5.09 1.241 8.2786 .086 .17 .600 3.53 .784 4.61 1.261 7.4289 .089 .18 .610 3.39 .794 4.41 1.271 7.0694 .094 .20 .630 3.15 .814 4.07 1.291 6.4696 .096 .21 .640 3.05 .824 3.92 1.301 6.20100 .100 .23 .660 2.87 .844 3.67 1.321 5.74104 .104 .25 .680 2.72 .864 3.46 1.341 5.36109 .109 .27 .700 2.59 .884 3.27 1.361 5.04113 .113 .31 .740 2.39 .924 2.98 1.401 4.52120 .120 .34 .770 2.27 .954 2.81 1.431 4.21125 .125 .37 .800 2.16 .984 2.66 1.461 3.95

MeteredFlow

FreeFlow

Page 50: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

About O'Keefe Controls Co.

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2000 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Founded in 1975, the company manufactures specialtyfluid control products in its Monroe, CT location. Chiefamong the products is an extensive line of precisionorifices for accurate metering of liquids or gases. Otherproducts include miniature in-line screens for use withsmall orifices, and several unique pneumatic sensorsused in industrial control applications.

The company provides extensive engineering sup-port for product selection and application to its cus-tomers. Accurate calibration of orifices can also beprovided using in-house NIST traceable instrumenta-tion.

O'Keefe Controls Co. encourages inquiries forcustom fluid control products from its customers. Spe-cial orifice sizes, configurations, and flow specifica-tions are routinely satisfied on an attractive economicscale. Please call with your special requirements.

At O'Keefe Controls Co. there are severalimportant steps in the production of preci-sion fluid restrictors. All orifice assembliesare 100% cleaned, inspected under a micro-scope, and flow tested before shipment.

With orifice diameters as small as .0003" itis important to have the assembly cleanedso that physical contaminants do not ob-struct flow through the orifice.

The ultimate objective of a precision fluidrestrictor is to accurately meter the flow ofa gas or liquid. The restrictors available fromO'Keefe Controls Co. are 100% tested andmust meet exacting flow standards beforeshipment.

Precision Orifice Processing at O'Keefe Controls Co.

Ultrasonic cleaners are used to remove con-tamination from the interior of orifice assem-blies. Small particles can cause majorchanges in orifice flow rates.

Orifice diameter dimensions are checked us-ing a precision measuring microscope. Accu-racy is better than .0001".

Mass flowmeters are used for NIST traceable cali-bration of orifice flow.

All production orifices are flow tested and mustmeet exacting flow standards. A special testbench has been constructed for this purpose.

All production orifices are examined by expe-rienced inspectors using a microscope to de-tect contaminants and to assure orifice qual-ity.

See Catalog and Product Updates on our Website www.okcc.com

51

Page 51: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 1997 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

38

PRESSURE SPECIFICATIONS SWITCH UNIT PRESSURE TRANSDUCER UNIT

Polyester WithAdjustable Rated Aluminum Threaded Brass 316 S.S.Operating Overrange Open Enclosed & Brass Insert & & & All

Range (PSIG) ① Switch Switch Buna "N" Buna "N" Buna "N" Viton 316 S.S.

0 - 30" Hg (VAC) 50 OB36A OB31B KRV34A11 – KRV34A21 KRV34A32 –30" Hg (V) - 14 PSIG 50 OB26A OB21B KRV24A11 – KRV24A21 KRV24A32 –

0 - 4 PSIG 60 OB46A OB41B KRD40A11 KRD40A71 KRD40A21 KRD40A42 –0 - 9 PSIG 60 OB36A OB31B KRD30A11 KRD30A71 KRD30A21 KRD30A42 –2 - 18 PSIG 60 OB26A OB21B KRD20A11 KRD20A71 KRD20A21 KRD20A42 –2 - 18 PSIG 100 OB36A OB31B – – – – KRE30A444 - 36 PSIG 150 OB26A OB21B KRE20A11 KRE20A71 KRE20A21 KRE20A42 KRE20A446 - 60 PSIG 150 OB16A OB11B KRE10A11 KRE10A71 KRE10A21 KRE10A42 KRE10A44

10 - 100 PSIG 200 ① OB16A OB11B KRF10A11 KRF10A71 KRF10A21 KRF10A42 KRF10A4420 - 200 PSIG 400 ① OB16A OB11B KRG10A11 KRG10A71 KRG10A21 KRG10A42 KRG10A4430 - 300 PSIG 450 OB16A OB11B KRH10A11 – KRH10A21 KRH10A42 KRH10A4440 - 400 PSIG 500 OB16A OB11B KRJ10A11 – KRJ10A21 KRJ10A42 KRJ10A4460 - 600 PSIG 2000 OB26A OB21B – – KRL20A21 KRL20A42 _

100 - 1000 PSIG 2000 OB16A OB11B – – KRL10A21 KRL10A42 –160 - 1650 PSIG 5000 OB26A OB21B – – KRN20B21 KRN20B42 –270 - 2700 PSIG 5000 OB16A OB11B – – KRN10B21 KRN10B42 –600 - 6000 PSIG 9000 OB16A OB11B – – – KRQ10B42 –

NON-ELECTRIC

Pneumatic Pressure Switches

DescriptionThe pneumatic pressure switch combinesa pressure sensing element and a spoolvalve to produce a switching device withan adjustable setpoint. The assembly isnon-electric, using only air or inert gas inthe switch unit.

The assembly consists of two components,a switch unit and a transducer unit. Theswitch unit contains a mechanically actu-ated, five ported spool valve which pro-vides the output signals. The transducerunit senses the pressure of a wide varietyof liquids or gases and transmits a me-chanical movement, at the preset pressurelevel, to the switch unit.

Open pneumatic pressure switch assembly.Five ported four way valve is actuated bytransducer mechanical displacement whenpressure exceeds adjustable set point. Shownwith optional barb connectors installed.

Pneumatic pressure switch has gasketedenclosure. Adjusting nut sets pressure at whichpneumatic valve is actuated. Shown withoptional barb connectors installed.

SWITCHING VALVE

5 ported, 4 way

10-32 threaded female connections

Operating Pressure of 5 working ports– vacuum to 100 psig

Working Fluid – Clean Dry Air or In-ert Gas

Air Usage – Leakage to atmosphereapproximately .002 SCFM at 100 psig

Cv – .12

Flow Capacity – 6.5 SCFM at 100 psig

PRESSURE TRANSDUCERWetted Materials – See chartConnection – 1/4" NPTRange – Vacuum to 6000 psigDeadband – less than 15% of range (316SSdiaphragm less than 25% of range)Repeatability – ± 2% of range

TEMPERATURE RATINGSAmbient -4ºF to 122ºFBuna-N -4ºF to 180ºFViton -4ºF to 250ºF316SS -50ºF to 300ºFPolyester -4ºF to 130ºF

Ordering InformationA pressure switch assembly consists of aswitch unit and a pressure transducer unit.

For Example:OB46A / KRD40A32

Switch Unit Transducer Unit

To select an assembly refer to specifica-tions chart above.1. Determine the pressure range required.2. Check that rated overrange pressure

rating is sufficient.3. Read across and select a switch unit

with the type of enclosure required.4. Continue across the same line and se-

lect a transducer compatible with theliquid or gas application.

Specifications① Rated overange pressure on KRF10A71 is 150 PSIG and on KRG10A71 is 300 PSIG

Request form OK-043 for more information.

Catalog Numbers

Page 52: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 1997 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

39

NON-ELECTRIC

DescriptionThe pneumatic temperature switch com-bines a temperature sensing element anda spool valve to produce a switchingdevice with an adjustable setpoint. Theassembly is non-electric, using only airor inert gas in the switch unit.

The assembly consists of two compo-nents, a switch unit and a transducerunit. The switch unit contains a me-chanically actuated, five ported spoolvalve which provides the output signals.The transducer unit senses the tempera-ture of a wide variety of liquids or gasesand transmits a mechanical movement,at the preset temperature, to the switchunit.Pneumatic temperature switch with direct mount

transducer unit. Open switch unit shown.

Pneumatic Temperature Switches

Pneumatic temperature switch with capillary andbulb transducer unit. Enclosed switch unit shown.

SpecificationsSWITCHING VALVE

5 ported, 4 way

10-32 threaded female connections

Operating Pressure of 5 working ports– vacuum to 100 psig

Working Fluid – Clean Dry Air or In-ert Gas

Air Usage – Leakage to atmosphereapproximately .002 SCFM at 100 psig

Cv – .12

Flow Capacity – 6.5 SCFM at 100 psig

Ambient Temperature – minus 4°Fto plus 122°F

TEMPERATURE TRANSDUCERSensor Materials – Sensing bulb avail-able in copper or 316 SS

Direct Mount Connection – 1/2" NPT

Capillary and Bulb Connection – Fitsinto thermal well or union connector.Bulb is 3/8" diameter.

Setpoint Range – minus 60°F to plus510°FDeadband – 8°F or less

Ordering InformationA temperature switch assembly consistsof a switch unit and a temperature trans-ducer unit.

For Example:

OB16A / OKF11A1

Open Frame 6' Capillary (Cu)Switch Unit Transducer Unit

Range 50-160°F

To select an assembly refer to specifi-cations chart above.

1. Determine the adjustable tempera-ture range required (left column).

2. Check that rated overrange tempera-ture is sufficient for the application.

3. Read across and select either an openframe or enclosed switch unit(OB16A or OB11B).

4. Continue across the same line andselect the required direct mount orcapillary and bulb transducer unit.

Catalog Numbers

Request form OK-088 for more information.

* °C = (°F -32) X 5/9 **Rated overrange temperatures are limited as follows: For copper capillary units -550°F. For direct mount units -260°F.

TEMPERATURE SPECIFICATIONS SWITCH UNIT TEMPERATURE TRANSDUCER UNIT

Adjustable Rated** 6' Capillary 12' CapillaryOperating Overrange Direct Mount

And Bulb And BulbRange Temperature Open Enclosed

°F* °F* Switch Switch Copper 316 SS Copper 316 SS Copper 316 SS

–30 - 60 250 OB16A OB11B OKB10A1 OKB10A4 OKB11A1 OKB11A4 OKB11A1D OKB11A4D

0 - 90 300 OB16A OB11B OKD10A1 OKD10A4 OKD11A1 OKD11A4 OKD11A1D OKD11A4D

50 - 160 350 OB16A OB11B OKF10A1 OKF10A4 OKF11A1 OKF11A4 OKF11A1D OKF11A4D

100 - 220 450 OB16A OB11B OKJ10A1 OKJ10A4 OKJ11A1 OKJ11A4 OKJ11A1D OKJ11A4D

160 - 260 500 OB16A OB11B OKL10A1 OKL10A4 OKL11A1 OKL11A4 OKL11A1D OKL11A4D

225 - 340 600 OB16A OB11B – – OKN11A1 OKN11A4 OKN11A1D OKN11A4D

300 - 450 700 OB16A OB11B – – OKT11A1 OKT11A4 OKT11A1D OKT11A4D

350 - 510 800 OB16A OB11B – – OKU11A1 OKU11A4 OKU11A1D OKU11A4D

Page 53: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

APPLICATIONS• High Speed Part Sensing: Rapid

response time of sensor.• Manufactured Parts: Counting, Gaging,

Position, Presence.• Containers and Packages: Counting,

Motion, Presence.• Die Protection: Part or Stock Presence

and Position.• Machine Control: Cam Position, Part

Position, Stock Position.• Paper, Film, Textile Sensing: Splice,

Edge, Double Thickness Detection.

SPECIFICATIONS

Supply Pressure: Up to 10 psig.

Supply Flow: 0.5 scfm @ 1 psig2.3 scfm @ 10 psig

Output Signal Pressure: See Output Pres-sure vs. Range Curves. Generally used totrigger air/air amplifier or air/electric switch.

Response Time: 1 millisecond (measuredat sensor output).

Sensing Range: See Output Pressure vs.Range Curves. Nominal maximum range is1/8 inch.

Materials of Construction:Body – Stainless SteelConnectors – Brass, DelrinTubing – Polyurethane

Air Supply Requirements: Dry air filtered to1 micron.

Minimum Target Size:Stationary Objects Minimum Size

Cylinder 1/8" dia.Slot 0.090" w.Circular Hole 0.130" dia.Circular Disc 0.130" dia.

Moving TargetsPulse Duration Object Size - In(sec) Approx.

= Object Velocity - In/sec

GENERAL DESCRIPTION

The air proximity sensor is a non-contact,no-moving-part sensor, capable of detect-ing the presence of an object at ranges up to1/8". In the absence of an object, air flowsfreely from the sensor resulting in a nearzero output signal. The presence of an ob-ject within the sensing range deflects thenormal air flow and results in a positiveoutput signal.

At low supply pressure, flow from thesensor exerts only minute force on the ob-ject being sensed and is consequently ap-propriate for use where the object is light-weight, or easily marred by mechanical sen-sors. Since there are no moving mechanicalparts in the air proximity sensor, there are noinherent wear mechanisms or life limita-tions. In this regard, the sensor is not cycledependent and is particularly appropriatefor applications requiring large numbers ofcycles. Also, the air proximity sensor isinherently explosion-proof and self-purging.Consequently, it is suitable for many ad-verse environments.

Ps 4 PSIG

Ps 6 PSIG

Ps 8 PSIG

Ps 10 PSIG

Ps 2 PSIG

Ps 1 PSIG

SENSOR OBJECT

Po Ps

RANGE

NOTEOUTPUT PRESSURES SHOWN ARETYPICAL AND ACTUAL SENSORSOBTAINED MAY VARY DUE TOMANUFACTURING TOLERANCES

3.5

3.0

2.5

2.0

1.5

1.0

.5

0

7

6

5

4

3

2

1

0

Ps 1 PSIG

Ps 3/4 PSIG

Ps 1/2 PSIG

Ps 1/4 PSIG

SENSOR OBJECT Po Ps

RANGE

NOTEOUTPUT PRESSURES SHOWN ARETYPICAL AND ACTUAL SENSORSOBTAINED MAY VARY DUE TOMANUFACTURING TOLERANCES

RANGE (IN).020 .060 .080 .120.100 .140 .160 .1800 .040

OU

TP

UT

PR

ES

SU

RE

– P

o -

Psi

g

OUTPUT SIGNAL PRESSURE VS. RANGESUPPLY PRESSURE 1 THRU 10 PSI

PERFORMANCE CHARACTERISTICS (For General Reference Only)OUTPUT SIGNAL PRESSURE VS. RANGE

SUPPLY PRESSURE 1/4 THRU 1 PSI

RANGE (IN).020 .040 .060 .080 .100 .120 .140 .160 .1800

OU

TP

UT

PR

ES

SU

RE

– P

o -

In

H2O

AIR PROXIMITYSENSOR

O KeefeO Keefe'' Cont rols Co.Cont rols Co.

Fax (203) 261-8331 Toll Free Phone (800) 533-3285 CT Phone (203) 261-6711Mailing Address Location

P.O. Box Q 4 Maple DriveTrumbull, CT 06611 © O'Keefe Controls Co. 1993 All Rights Reserved Monroe, CT 06468

Page 54: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Air Proximity Sensor

Air Proximity Sensor Symbol

5/64 OD OUTPUT CONNECTIONFOR 1/16" ID SOFT TUBING

3/4

1.625

1/4 DIA.

3/16" OD SUPPLY CONNECTIONFOR 1/8" ID SOFT TUBING

DIM. – IN.

SUPPLY PORT10-32 THREADCAN BE ROTATED

DIM. – IN.

OPTIONALMOUNTING BRACKET

STAINLESS STEEL TUBE

1-3/4

9/161-1/16

1-5/8

1-1/4

5/16

(4) # 16 (.178)DIA. HOLES

Air/Air AmplifierDESCRIPTIONThe air/air amplifier requires only low pressure signals to pilot a directional control valve,which in turn, can operate at supply pressures up to 100 psig. A control signal of 2" H2Opressure is sufficient to shift the 4 way valve and produce an output signal up to 100 psig. Themain valve is of five ported-4 way construction, and can be used additionally as a 3 way valve,either normally closed or normally open.

PROXIMITY SENSOR – INTEGRAL MOUNTINGP/N OKC-424

PROXIMITY SENSORP/N OKC 818 (Formerly 6080517)

When an object is located inside the sensing range, the sensor flow is deflectedwith a resultant pressure buildup in the output. This pressure signal is the "on"condition of the sensor. The amount of pressure sensed increases as the objectmoves closer to the sensor. Nominal maximum sensing range is 1/8 inch.

In the absence of an object disturbing the free flow of air exiting from the sensor,the output pressure signal is in an "off" condition. This "off" condition is a nearzero output pressure.

OUTPUTSIGNAL

OFF

NORMAL FLOW

OUTPUTSIGNAL

ON

OBJECTBEING

SENSED

FLOW CHANGED BYSOLID OBJECT

Principle of Operation

SPECIFICATIONSPART NO. KLUF2

Main Valve – 5 ports, 2 positions, 4 waySignal Pressure – Valve shifts at 2" H2O increasing pressure

Valve resets at 1/2" H2O decreasing pressureSupply Pressure – 30 to 100 psig

Pilot Pressure – 50 psig optimum pressureMain Valve Flow – Cv equals .08 (limited by 1/16" ID barbs)

Range of Proximity Sensor – Up to 1/8"Air/Amplifier Combination

9/16

3/16

ADJUSTABLEMOUNTING NUTS – 9/16 HEX.ASSEMBLY CAN MOUNTTHROUGH 1/2 " DIA. HOLE

3/4

SIGNAL PORT1/16" IDPOLYURETHANETUBING – 4' LENGTH

1/4 DIA.

OPTIONAL MOUNTING BRACKETP/N OKC 326

SYMBOL-AIR/AIR AMPLIFIER

SIGNAL

NORMALLYPASSINGFLOWPATH

NORMALLYNON PASSINGFLOWPATH

PILOTA

C

1

5

2

4

BARBS FOR 1/16" ID TUBING5 WORKING PORTS1 PILOT PRESSURE PORT1 AUXILLIARY CONTROL PORT

DIM. – IN.

2.23

1.45

.5 .71

1.37

1.15

1.70

.63

.30

.125

6-32 UNC TAP THRU - 2 PLACES

O KeefeO Keefe'' Cont rols Co.Cont rols Co.

© O'Keefe Controls Co. 1993 All Rights Reserved

SIGNAL PORT (C)10-32 UNF

AIR/AIR PRESSURE AMPLIFIERP/N KLUF2

Page 55: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Air/Electric SwitchesDESCRIPTIONThe air/electric switches presented here operate readily with the airproximity sensor. Each responds to low pressure air signals, and eachhas special characteristics which increase the total range of applica-tions of the air proximity sensor. Considerations in selecting a switchare current requirements, response time, differential or single endedoperations, and maximum required sensing range.

FEATURESP/N OKC-661 Excellent vibration resistance; small size; pressure,

vacuum or differential operation; fast response time.P/N OKC-664 Greatest current capacity (10 amps); pressure only;

SPDT contacts; moderate response time.P/N OKC-819 Smallest size; fastest response time; up to 60 mil-

liamps; pressure, vacuum or differential operation.

NOTES① A separate electrical connector is provided for soldering to the electrical wire

terminals. Soldering must be done with the electrical connectors removedfrom the switch to prevent damage to the switch contacts by soldering heat.

≠ When controlling inductive loads, such as small relays, it is good practice touse RC suppression or diodes, as required to prevent arcing.

➂ Range – Maximum sensing distance for combination of air proximity sensorand air/electric switch.

√ Response Time – Combined response time of air proximity sensor and air/electric switch.

LOW

HIGH

11/16

DETACHABLE COVER

1-21/32

DIM. – IN.

2-5/8

21/32

1-9/32

1-9/16

2 MTG. HOLES CLEARANCE FOR #6 SCR'S

SIGNAL INPUT FOR 1/16 IDFLEXIBLE TUBING

OKC-661 OKC-819-1 OKC-664 OKC-819-2

HIGH

LOW

N.ON.C.

COM.

1/2

1/2 3/4 SQ.

31/32

.100 DIA. MTG. HOLES(4 PLACES)

REMOVABLE 2-PINELECTRICAL SOCKET ➀

17/64

23/64

DIM. – IN.

CONNECTION FOR 1/16 IDSOFT TUBING (2 PLACES)

N.O. N.C.SPDT

1

3/83/16

5/16

23/32 1

17/8

23/32

3/16

CONNECTION FOR 5/32 IDSOFT TUBING (2 PLACES)

CLEARANCE FOR#2 SCR'S

DIM. – IN.

Specifications for P/N OKC-819P/N OKC-819-1 Normally Open (air to(formerly 6080157) make contacts)P/N OKC-819-2 Normally Closed (air to(formerly 6080503) break contacts)Type Single Pole Double BreakMaximum Current 60 ma @ 120 volts-ACFor Resistive Load 40 ma @ 120 volts-DCMedia Air or inert gas onlyDifferential Pressure 1" H2O minimumTo Operate 1 psig maximumResponse Time ④ 10 millisecInput Connections For 1/16" ID tubingBody Materials PlasticTerminals Solder connections ➀ ➁Range ③ 1/8" maximum

Specifications for P/N OKC-664P/N OKC-664 Air to actuate (positive(formerly 6080158) pressure only)Type Single Pole DoubleThrowMaximum Current 10 amps @ 125 orFor Resistive Load 250 VACMedia Air or inert gas onlyPressure to 4" H2O minimumOperate 5 psig maximumResponse Time ④ 50 millisecInput Connection For 1/16" ID tubingBody Materials PlasticTerminals Screw styleRange ③ 3/32" maximum

Specifications for P/N OKC-661P/N OKC-661 Normally Open

(air to make contacts)Type Single Pole Double BreakMaximum Current 200 ma @ 30 VDCFor Resistive Load Neon lamp @ 120 VACMedia Air or inert gas onlyDifferential Pressure 0.5" H2O minimumTo Operate 1 psig maximumResponse Time ④ 20 millisecInput Connections For use with 5/32" ID tubingBody Materials PlasticTerminals 3/16" Male Tab Type.

Mating connectors furnishedRange ③ 1/8" maximum

O KeefeO Keefe'' Cont rols Co.Cont rols Co.

© O'Keefe Controls Co. 1993 All Rights Reserved

Page 56: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

MAGNETICSENSING VALVE

SPECIFICATIONSVALVEType – 2 position, 3-way normally closed; actuated by magnet or steel partMedia – dry, oil free compressed air or inert gasFiltration – 5 micronPressure Limit – 30 to 100 psigTemperature – +35° to 140 °FValve Orifice – .080" diameterAir Flow – No continuous air flow usage when valve deactuatedConnections – Barbs for 3/32" ID tubingIndicator – 1/16" blue indicator extends outward (approximately 1/16" stroke) when valve actuated

Materials of Construction Switch Body – Plastic Barbs – Brass

SENSING CHARACTERISTICSRange – Greater than 1/16". Varies with part size and geometryPart Size Detectable – Senses wire diameter down to .040"Position Repeatability – Less than .010" of switch point

DIMENSIONS

DESCRIPTIONThe magnetic sensing valve detects the pres-ence of a magnet or steel part in its near vicin-ity. The 3-way normally closed air valve is ac-tuated when in the presence of a small mag-net or steel part. The valve deactuates whenthe small magnet or steel part is removed.

FEATURES• Non-contact sensing• Non-ferrous material can be interposed

between sensor and sensed part• Range is greater than 1/16" (varies with

part geometry)• Explosion proof (only air or inert gas used

in valve)• Rapid response time• Repeatability of switch point (less than

.010")

APPLICATIONS• Used as limit sensor on air or hydraulic

cylinders with magnetic piston• Detecting lobe position on rotating cam• Steel wire presence or breakage• Alternate to reed switches• Detection of electromagnetic fields

ORDERING INFORMATIONDescription Part NumberSensing Valve OKC-1587Cylinder Band OKC-16885/32" OD x 3/32" OTU0425G20 ID Tubing (65 feet)Male Connector OKQ2H03-32 10-32 x 5/32" ODMale Connector OKQ2H03-34S 1/8" NPT x 5/32" OD

Valve DeactuatedPressure Port #1 is blocked. Vent Port #3is connected to Output Port #2.

Valve ActuatedPressure Port #1 is connected to OutputPort #2. Vent Port #3 is blocked.

© O'Keefe Controls Co. 1999 All Rights Reserved

Fax (203) 261-8331e-mail [email protected]

Mailing AddressP.O. Box Q

Trumbull, CT 06611

CT Phone (203) 261-6711website www.okcc.com

Location4 Maple Drive

Monroe, CT 06468

Toll Free Phone (800) 533-3285

Form OK-248

AIR VALVE SYMBOL

M4MountingThread(2 sides) 1.340

1.588

.772.710

Dim. – In.

2

1 3

Page 57: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

PNEUMATICFLOAT SWITCH

[Non-Electric]SPECIFICATIONSFLOAT AND BODYTemperature Limit – 220° FPressure Limit – 350 psigMinimum Specific Gravity – 0.5 SGWetted Materials Brass Body; 301 SS, 304 SS, Ceramic Stainless Steel Body; 303 SS, 301 SS, 304 SS, CeramicInstallationHorizontal Switch – For side mounting to vessel, Installation arrow must point downwardVertical Switch – For top mounting

PNEUMATIC SWITCHFluid Media – Clean compressed air or inertgases, filtration < 40 micronsOperating Pressure – 30 to 100 psigOperating Temperature – 35° to 140°FValve Connections – For 3/32" ID tubing (2.5 mm)

Air Supply Port #1Output Port #2Vent Port #3

Valve Operation – The magnetically actuatedvalve is 3 way - normally closed. The valve isactuated when the liquid lifts the SS float.

Actuated Flow Path De-Actuated Flow PathPort #1 - Port #2 Port #3 - Port #2(Blue Indicator Extended) (Blue Indicator Retracted)

Actuation Indicator – 1/16" diameter/Blue Indi-cator extends outward (approximately 1/16"stroke) when float is lifted.Air Flow – No continuous air flow usage.Air Valve Orifice – .080" diameterMaterials of Construction

Brackets – Anodized AluminumSwitch Body – PlasticConnection Barbs – Brass

DESCRIPTIONThe Magnetic Float Switch is an air sensor fordetecting liquid level inside a vessel. The floatmechanism mounted within the vessel oper-ates a ceramic coated magnet. As the floatmoves it pivots the magnet. A magneticallyactuated sensor on the outside of the solidmetal housing reacts to the inner magnetmovement. The movement shifts a 3 way airvalve.

FEATURES• Explosion Proof• No electrical hazard• For vented or non-vented vessels• Stainless steel float mechanism• Side mounting or top mounting selection• 3 way pneumatic valve• Actuation indicator on 3 way valve• Magnetic coupling-float to valve• Minimum air usage

AIR VALVE SYMBOL

Valve Deactuated (float low)Pressure Port #1 is blockedVent Port #3 is connected to OutputPort #2

Valve Actuated (float high)Pressure Port #1 is connected to OutputPort #2Vent Port #3 is blocked

Horizontal float switch for side mounting to ves-sel. Float operates air valve on outside of vessel.

Float mechanism is contained inside a solid metalbody. The air switch is located outside the metalbody and is magnetically actuated.

Vertical float switch is mounted ontop side of closed or vented vessels.

© O'Keefe Controls Co. 1999 All Rights Reserved

Fax (203) 261-8331e-mail [email protected]

Mailing AddressP.O. Box Q

Trumbull, CT 06611

CT Phone (203) 261-6711website www.okcc.com

Location4 Maple Drive

Monroe, CT 06468

Toll Free Phone (800) 533-3285

1" NPTThread

SolidMetalBody Magnetic

Sensor

SSFloat

CeramicCoatedMagnet Air

Connections

SYMBOL2

1 3

Page 58: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

PNEUMATIC FLOAT SWITCH

Form OK-242

FLOAT SWITCH APPLICATIONS FLOAT SWITCH – ACCESSORIES

HORIZONTAL FLOAT SWITCH – SIDE MOUNTING VERTICAL FLOAT SWITCH – TOP MOUNTING

Catalog No. Body Installation Float Max. Float Pressure

OKC-1536-1 Brass Side Mounting Stainless Steel 350 psig

OKC-1536-2 Stainless Steel Side Mounting Stainless Steel 350 psig

OKC-1570-1 Brass Top Mounting Stainless Steel 350 psig

OKC-1570-2 Stainless Steel Top Mounting Stainless Steel 350 psig

PART NUMBERS

Description Part NumberMale Connector 10-32 x 5/32" OD OKQ2H03-32Male Connector 1/8" NPT x 5/32" OD OKQ2H03-34SMale Elbow 10-32 x 5/32" OD OKQ2L03-32Male Elbow 1/8"NPT x 5/32" OD OKQ2L03-34SBulkhead Union 5/32" tubing OKQ2E03-00Union Tee For 5/32" tubing OKQ2T03-00Tubing 5/32" OD (4mm) - green OTU0425G-20Cable Clamp Bracket 7/8" attachment hole OKC-1532Replacement Valve 3 way magnetic operation OKC-1587

Float switches can be used for high or low level alarms in anopen or closed vessel. In conjunction with a control panel theswitches are used to turn on/off pumps or open/close valves.

Fill Pipe

Drain Pipe

FloatSwitch

FloatSwitch

6.875"

1-3/8" Hex

1" NPT

1" Dia. x 2" Lg. Float

Cable Clamp BracketOKC-1532 Optional

TUBINGNOT INCLUDED

Monroe, CTP/N OKC-1536-2DOWN

7.688"

1" Dia. x 2" Lg.Float

1" NPT

1-3/8" Hex

Cable Clamp BracketOKC-1532 Optional

TUBINGNOT INCLUDED

Mon

roe,

CT

P/N

OK

C-1

570-

2

© O'Keefe Controls Co. 1999 All Rights Reserved

Page 59: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Monroe, Connecticut Catalog AD-1

• DesiccantAir Dryers

• Point-of-UseAir Dryers

• Accumulators

• AutomaticDrain Valves

• Filters/Regulators• Pneumatic

Controls

COMPRESSEDAIR DRYERS

AND ACCESSORIES

Page 60: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Picture Index2

WHERE TO FIND IT

Compact Air Dryer

pages 4-6

About O'Keefe Controls Co.Founded in 1975, the company manufactures specialty fluidcontrol products in its Monroe, CT location. In addition tothe air dryer products is an extensive line of precisionorifices for accurate metering of liquids or gases. Otherproducts include miniature in-line screens for use with smallorifices, check valves, flow controls and several uniquepneumatic sensors used in industrial control applications.

The company provides extensive engineering supportfor product selection and application to its customers. Accu-rate calibration of orifices can also be provided using in-house NIST traceable instrumentation.

O’Keefe Controls Co. encourages inquiries for customfluid control products from its customers. Custom air dryerproducts can be manufactured; special orifice sizes, con-figurations, and flow specifications can be satisfied on anattractive economic scale. Please call with your specialrequirements. See our other catalogs on our website atwww.okcc.com.

Compact Air Dryer is shoebox size.Air flow up to 6 scfm.

Standard Module Standard System High Flow Module

pages 7-9pages 10-12

pages14-16

Standard module is field mountable.Air flows up to 13 scfm. Watertightelectric connections.

Standard system includes prefilter,coalescing filter and air dryer.

High Flow Module will handle airflows up to 20 scfm. Field mountablewith watertight electric connections.

Point-of-Use Dryer

page 17

Point-of-use dryer is located wherecondensate problems exist.

Accumulators Automatic Drain Valves Accessoriespage 13

pages 20-21

pages 18-19

Accumulators dampen pulsation ofair flow and provide storage for surgeflow requirements.

Automatic drain valvesdump collected condensate.

Adjustable time duration.

Check Valves

page 22

Check valves for vacuum or pressureapplications.

Fixed Flow Controls

page 22

Fixed flow control valves set thestroke speed of cylinders.

Pneumatic Sensors

page 23

Air sensors for liquid level, pressure,temperature, flow and proximity.

Accessoriesincludefilters,regulators,pressuregages,chemicaldryers andmoistureindicators.

Page 61: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

SELF-REGENERATIVE

Low Dew Point Air Dryers 3

DescriptionThe air dryer products of O'Keefe Controls Co. employ a self-regenerative, desiccant style drying system. "Self-regenerative"means that the dryer automatically and continuously dischargescollected water vapor which has been removed from the air passingthrough the system. Desiccant style means that a material(a desiccant) is used to selectively remove water vapor from the airsurrounding this material. Three common desiccant materials aresilica gel, alumina and molecular sieve.

How It Works!In the O'Keefe Controls Co. air dryers desiccant material is amolecular sieve. This type desiccant absorbs the water vapormolecule in tiny pores on the surface of each bead of the molecularsieve material. Moist air passing by this desiccant is dried as vapormolecules are selectively attracted to the pores in the molecularsieve beads. A dew point as low as minus 100°F is possible usingmolecular sieve material.

Another equally important characteristic of the molecular sieve isthat extremely dry air (very low dew point) passing by thisdesiccant will reabsorb the water vapor trapped in the pores; thusproviding a means of automatic regeneration of the desiccant.

Two desiccant tanks are employed in each air dryer. Wet pressur-ized air enters one tank and is dried as it passes through to the outlet.A portion of the dried air is directed into the top of the second tankthrough a purge orifice and flows at near atmospheric pressurethrough this tank to atmosphere. As this dry air passes around themolecular sieve beads it reabsorbs water vapor and then exhauststo atmosphere.

Flow Patterns in Desiccant Air DryerThe flow patterns shown below have a repeating cycle period of 60seconds. For 30 seconds the left tank is pressurized; for 30 secondsthe right tank is pressurized.

Dew Point and Relative HumidityDew Point – Temperature at which condensation begins. Air is fullysaturated with water vapor at this temperature.Atmospheric Dew Point – Dew point when air is at atmosphericpressure.Pressure Dew Point – Dew point when air is at elevated pressureabove atmospheric pressure.Relative Humidity – Ratio of the actual water vapor content to thesaturated water vapor content.See chart below.

Weight of Water In a Cubic Foot of Air at Various Temperatures Weights shown in grains 7,000 grains = 1 lb.

Temp Relative Humidity Temp.

°C 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%°F-6.7 .124 .247 .370 .494 .618 .741 .864 .988 1.11 1.24 20

4.4 .285 .570 .855 1.14 1.42 1.71 1.99 2.28 2.56 2.85 40

15.6 .575 1.15 1.72 2.30 2.87 3.45 4.02 4.60 5.17 5.75 60

26.7 1.09 2.19 3.28 4.37 5.47 6.56 7.65 8.75 9.84 10.93 80

Construction of Desiccant TankThe desiccant tank construc-tion is vital to reliable opera-tion of the air dryer. As shownat left the desiccant beads aremaintained in place by filtermedia and screens. The unit isspring loaded to counteract highpressure pulses which occurduring switching of the air flow.

Main Flow Out

Load SpringSupport ScreenFine ScreenFilter MediaMolecularSieve Beads

Filter Media

Fine Screen

Support Screen

Main Flow In

Left Tank Pressurized – First Half of Cycle Right Tank Pressurized – Second Half of Cycle

High pressure airflows through the righttank for 30 seconds.At the same time drypurge air is expandedto near atmosphericpressure through apurge orifice andreabsorbs moisturefrom the desiccantbeads in the left tank.

High pressure airflows through the lefttank for 30 seconds.At the same time drypurge air is expandedto near atmosphericpressure through apurge orifice andreabsorbs moisturefrom the desiccantbeads in the right tank.

Wet Air In

Dry Air OutPurge Orifice

Valves andTiming Controls

Moist PurgeAir Out

■■■■■ High Pressure

■■■■■ Low Pressure

Dry Air Out

Wet Air InMoist PurgeAir Out

Valves andTiming Controls

Fixed FlowControl (2)

Purge Orifice

Desiccant Tankwith MolecularSieve (2)

Moist PurgeAir Flows toAtmosphere

Page 62: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Compact Air Dryer4

SHOE BOX SIZE

DescriptionThe compact air dryer series meets theneeds of certain low flow applicationswhere very dry compressed air isrequired, i.e., atmospheric dew point ofminus 50°F or lower. Designed tominimize space, the shoebox size unit iseasily installed in tight spaces.

The self-regenerative air dryer can beoperated continuously at flow ratesranging from 0-0.5 scfm up to 0-6 scfm atminimum inlet pressures of 80 psig.

Easy installation requires only inlet andoutlet air connections and plug-in to anelectric outlet.

Applications• Instrument air systems• Dental/medical equipment• Industrial pneumatic controls• Air bearing systems• Pneumatic controls in sub-freezing

environments• Air operated vacuum pickups• Fluidics/MPL controls• Cyrogenics• Sub-freezing air blow-off jets• Paint spray guns• Microwave air guides

FeaturesMinimum Maintenance – Simplicityof design, few moving parts, self-regenerating desiccant tanksInstant Dry Air – No warm-up timeLow Dew Point – Down to -100°FQuiet Operation – Exhaust mufflerLong Life Desiccant – Under normalconditions, the desiccant material doesnot require replacementMetal Bowl Guard – Transparent bowlsElectric Plug/Cord – 10 ft. cord with3-prong plug

SpecificationsInlet Pressure – 80 to 150 psigMaximum Inlet Temperature – +125°FDew Point – minus 50°F @ 80 psig inletpressure; consult factory for lowerdew point applicationsMedium – Oil-free compressed airOutput Flow Rate – See chart page 5Purge Flow – See chart page 5Air Connections/Inlet and Outlet –1/4" NPT – FemaleMounting – 4 mounting holes 5/16" dia.Mount unit with tanks vertical andupright onlyDimensions – See chart page 5Filter Rating –

1557F 0.1 microns1558F, 1559F 0.01 microns

Prefilter and coalescing filter combinationremove liquid water and oil and solidparticles from air stream before it entersinto dryer module.Filter Drains –

1557F Manual1558F, 1559F Automatic

Weight –1557F 8 pounds1558F 10 pounds1559F 12 pounds

Electric Power – 120 volts/60 hzElectric Connection – 10 ft. cord with3-prong plugEnclosure Rating – Type 1

Benefits• Pipe rust eliminated• Longer tool and instrument life• Drier air than in refrigeration

systems• No heat wasted• No electrical hazards• Condensate eliminated• Water vapor virtually nonexistent

Prefilter and coalescing filters removesolids, liquid water and oil from air streambefore it enters into dryer module.

Compact air dryer with 6" desiccant tanks– with prefilter and coalescing filter.

Compact air dryer with 6" desiccant tanks– no filters.

MountingBracket

TimingControls

Inside

CoalescingFilter

.1 or .01microns

Prefilter5 microns

Electric Cord (10 ft)with 3-prong plug

DesiccantTanks

Page 63: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

LOW DEW POINT

Compact Air Dryer 5

Ordering InformationFrom the part number chart belowleft, select an air dryer that will pro-vide the outlet air flow required.

For exampleOutlet flow required 2.0 scfm• Assembly complete with filters;

Part Number is OKC-1558-1F• Assembly without filters;

Part Number is OKC-1558-1• Assembly complete with filters and

with moisture indicator; Part Number is OKC-1558-1FM

Optional MoistureIndicatorAdd the suffix M to the air dryer partnumber to include the optional mois-ture indicator. To order the moistureindicator separately, use part numberOKC-1739.

Optional Output FilterAdd the suffix P to the air dryer partnumber to include an output filter.

For exampleOKC-1558-1FP This assembly iscomplete with inlet filters and an out-put filter.

To order the output filter separately,use part number from the chart onpage 6.

Part Number A B C D

OKC-1557 (All) 6" — — 11-9/16"

OKC-1558 (All) 9" — — 14-9/16"

OKC-1559 (All) 12" — — 17-9/16"

OKC-1557F (All)* 6" 10-13/32" 11-1/4" 11-9/16"

OKC-1558F (All)* 9" 15-29/32" 12-13/16" 14-9/16"

OKC-1559F (All)* 12" 18-29/32" 12-13/16" 17-9/16"

Dimensions

8"

3-3/8"

(4) 5/16" Dia.Mt'g. Holes

MoistureIndicator -Optional

OptionalOutput Filter Alternate Inlet

ConnectionMuffler - Typical

CoalescingFilter

Prefilter

Alternate OutletConnection

C

B

6-13/32"

Filters

4-3/4"7-1/8"

A

D

Max Outlet Purge Flow MaxAir Dryer Flow Rate Rate at System

Part at 80 psig 80 psig Air DewNumber* and 70°F and 70°F Pressure Point

OKC-1557-1OKC-1557-1F 0.5 scfm 0.1 scfm 150 psig -50°FOKC-1557-2

OKC-1557-2F 1.0 scfm 0.2 scfm 150 psig -50°FOKC-1557-3

OKC-1557-3F 1.5 scfm 0.3 scfm 150 psig -50°FOKC-1558-1OKC-1558-1F 2.0 scfm 0.4 scfm 150 psig -50°FOKC-1558-2

OKC-1558-2F 3.0 scfm 0.6 scfm 150 psig -50°FOKC-1558-3

OKC-1558-3F 4.0 scfm 0.8 scfm 150 psig -50°FOKC-1559-1OKC-1559-1F 5.0 scfm 1.0 scfm 150 psig -50°FOKC-1559-2

OKC-1559-2F 6.0 scfm 1.2 scfm 150 psig -50°F

Part Numbers

*Dryers with suffix F in part number include prefilter and coalescing filters.

Page 64: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Compact Air Dryer6

REPLACEMENT PARTS

Parts for Compact Air DryersDescription Qty. Part Number

Moisture Indicator 1/4" NPT 1 OKC-1739

Muffler 1/4" NPT 2 OKC-1751

Solid State Timer 120/240 volts 50/60 hz 1 OKC-1752

Solenoid Valve 3-way N.C. 53 VDC (special) 2 OKC-1753-1

Solenoid Valve Repair Kit 2 OKC-1753-2

Solenoid Valve Coil 2 OKC-1753-3

Desiccant Tanks for OKC-1557 (6") 2 OKC-1754-1

Desiccant Tanks for OKC-1558 (9") 2 OKC-1754-2

Desiccant Tanks for OKC-1559 (12") 2 OKC-1754-3

Prefilter Assembly for OKC-1557 (6") 1 OKC-1737-1

Prefilter Cartridge for OKC-1557 (6") 1 OKC-1742-1

Coalescing Filter Assembly for OKC-1557 (6") 1 OKC-1738-1

Coalescing Filter Cartridge for OKC-1557 (6") 1 OKC-1743-1

Prefilter Assembly for OKC-1558 (9") 1 OKC-1737-2

Prefilter Cartridge for OKC-1558 (9") 1 OKC-1742-2

Coalescing Filter Assembly for OKC-1558 (9") 1 OKC-1738-2

Coalescing Filter Cartridge for OKC-1558 (9") 1 OKC-1743-2

Prefilter Assembly for OKC-1559 (12") 1 OKC-1737-2

Prefilter Cartridge for OKC-1559 (12") 1 OKC-1742-2

Coalescing Filter Assembly for OKC-1559 (12") 1 OKC-1738-2

Coalescing Filter Cartridge for OKC-1559 (12") 1 OKC-1743-2

Output Filter Assembly for OKC-1557 (6") 1 OKC-1737-1

Output Filter Cartridge for OKC-1557 (6") 1 OKC-1742-1

Output Filter Assembly for OKC-1558 (9") 1 OKC-1737-2

Output Filter Cartridge for OKC-1558 (9") 1 OKC-1742-2

Output Filter Assembly for OKC-1559 (12") 1 OKC-1737-2

Output Filter Cartridge for OKC-1559 (12") 1 OKC-1742-2

Page 65: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

INSERT MODULE

Standard Air Dryer 7

DescriptionThe 311C series air dryer is an insert module intended to be installedwithin an enclosure. The unit is a self-regenerative compressed air dryerwhich removes water vapor continuously using a molecular sievedesiccant material. Two stainless steel tanks contain the desiccant. Atimer, solenoid valve and two flow control valves sequence the air flowalternately through one tank and then the other. A small amount of purgeflow is discharged continuously. A nominal dew point of -50°F isachieved at maximum flow rate; even lower dew point at less thanmaximum flow. Compressed air supplied to the dryer should be clean(5 microns) and oil-free.

SpecificationsInlet Pressure – 80 to 125 psigMaximum Inlet Temperature – +125°FDew Point – See chart for typical conditions – page 9. The lower theoutlet flow, the lower the dew point.Medium – Oil-free air; filtered to 5 micronsOutput Flow Capacity – See chart for typical conditions – page 9Purge Flow – See chart for typical purge flow – page 9Air Connections – Inlet and outlet – 1/4" NPT FemaleMounting – Mount unit with tanks vertical; four mounting holesDimensions – 14-3/4" x 12-7/8" x 4" – See drawing page 9Electric Motor and Solenoid Valve – 120 volts/60 hz/single phase/15 wattsElectric Connections – Terminal stripWeight – Approximately 21 pounds

Recommended Operation• Install the 311C module in an enclosure to protect against inadvert-

ent contact with electric terminals.• Always provide clean air to the dryer. Use a prefilter (OKC-730) to

remove solid contamination and a downstream coalescing filter(OKC-731) to remove liquid water and oil.

• The dryer can be continuously operated.• The output air pressure/flow has a momentary pulse as the solenoid

valve switches flow (every 30 sec.). To reduce the pulsation, installa check valve and accumulator (see page 13) at the outlet of theair dryer.

Ordering InformationMax Flow Rate (scfm) Purge Flow Rate (scfm)

Part Number 80 psig Supply 80 psig Supply311C-16 2.0 .35311C-22 3.4 .68311C-31 6.0 1.2311C-39 9.0 1.8311C-46 13.0 2.6

311C air dryer module has field replaceable components.Unit can be continuously operated.

311C series air dryer – module for installation in enclosure.Unit is capable of achieving -50°F atmospheric dew point.

Fixed FlowControls (2)

4-waySolenoidValve

MufflerSSDesiccantTanks (2)

Timer

Page 66: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Standard Air Dryer8

FIELD MOUNT

DescriptionThe 2016 series air dryer employs a solid state timer. Electric connectionsemploy a DIN 43650 connector which is gasketed and protected againstinadvertent contact. The unit is a self-regenerative compressed air dryerwhich removes water vapor continuously using a molecular sieve desiccantmaterial. Two stainless steel tanks contain the desiccant. A timer, solenoidvalve and two control valves sequence the air flow alternately through onetank and then the other. A small amount of purge flow is dischargedcontinuously. A nominal dew point of -50°F is achieved at maximum flowrate; even lower dew point at less than maximum flow. Compressed airsupplied to the dryer should be clean (5 microns) and oil-free.

SpecificationsInlet Pressure – 80 to 125 psigMaximum Inlet Temperature – +125°FDew Point – See chart for typical conditions – page 9. The lower theoutlet flow, the lower the dew point.Medium – Oil-free air; filtered to 5 micronsOutput Flow Capacity – See chart for typical conditions – page 9Purge Flow – See chart for typical purge flow – page 9Air Connections – Inlet and outlet – 1/4" NPT FemaleMounting – Mount unit with tanks vertical; four mounting holesDimensions – 14-3/4" x 12-7/8" x 4" – See drawing page 9Electric Timer and Solenoid Valve – 120 volts/60 hz/single phase/15 wattsElectric Connections – DIN 43650 (see optional cord below)Mating connector only – P/N OKC-2034Weight – Approximately 21 pounds

Recommended Operation• The 2016 series air dryer has protected electrical connections and can

be field mounted.• Always provide clean air to the dryer. Use a prefilter (OKC-730) to

remove solid contamination and a coalescing filter (OKC-731) toremove liquid water and oil.

• The dryer can be continuously operated.• The output air pressure/flow has a momentary pulse as the solenoid

valve switches flow (every 30 sec.). To reduce the pulsation, install acheck valve and accumulator (see page 13) at the outlet of the air dryer.

Ordering InformationMax Flow Rate (scfm) Purge Flow Rate (scfm)

Part Number 80 psig Supply 80 psig SupplyOKC-2016-16 2.0 .35OKC-2016-22 3.4 .68OKC-2016-31 6.0 1.2OKC-2016-39 9.0 1.8OKC-2016-46 13.0 2.6

Optional Cord P/N OKC-822A six foot long cord with a 3-prong plug for 120 volts/60 hz has a DIN connector for attaching to the timer.

Optional DIN Connector P/N OKC-2034Connector attaches to timer. Customer supplied 3-wirecord attaches to screw terminals in connector.

All major components of the 2016 series air dryers areeasily replaced.

Field mount air dryer has gasketed and protected electricalconnections.

Fixed Flow Control Valves (2)

DIN Connector

4-waySolenoid Valve

SolidStateTimer

Muffler

SS DesiccantTanks (2)

Page 67: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

SPECIFICATIONS

Standard Air Dryer 9

Operating Conditions for Standard Air Dryer

Field MountInsert Module12-7/8"

12-1/4"

(4) 9/32" Dia. Mounting Holes

5/16"1/4"

14-1/4"

14-3/4"

Parts for Standard Air DryersDescription Qty/Air Dryer Part Number

Timer for 311C Series 1 OKC-781

Timer for 2016 Series 1 OKC-2032

Solenoid Valve for 311C Series 1 OKC-779

Solenoid Valve for 2016 Series 1 OKC-2033

Muffler for 311C, 2016 Series 1 OKC-780

Desiccant Tank for 311C, 2016 Series 2 OKC-777

Flow Control Valves for 311C, 2016 Series:

311C-16, OKC-2016-16 2 Y4F-16-BR-DE

311C-22, OKC-2016-22 2 Y4F-22-BR-DE

311C-31, OKC-2016-31 2 Y4F-31-BR-DE

311C-39, OKC-2016-39 2 Y4F-39-BR-DE

311C-46, OKC-2016-46 2 Y4F-46-BR-DE

Din Connector for 2016 Series 1 OKC-2034

Model 311C, 2016 -16 -22 -31 -39 -46

Inlet pressure – PSIG 80 80 80 80 80

Inlet temperature –°F 70 70 70 70 70

Purge Flow – SCFM .35 .68 1.2 1.8 2.6

Outlet Flow – SCFM 2.0 1.4 1.2 3.4 2.7 2.2 6.0 4.8 4.0 9.0 7.2 6.0 13.0 10.4 8.8

Atmos. Dew Point –°F -50 -60 -65 -50 -60 -65 -50 -60 -65 -50 -60 -65 -50 -60 -65

Dew Point @ 80 PSIG –°F -18 -30 -35 -18 -30 -35 -18 -30 -35 -18 -30 -35 -18 -30 -35

12-7/8"12-1/4"

(4) 9/32" Dia. Mounting Holes

5/16"1/4"

14-1/4"

14-3/4"

Page 68: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

DescriptionSeries 415 and 416 air dryer systems include the 311C series dryer, anenclosure and two filters completely assembled and ready for installa-tion. The filters have automatic drains for discharge of collected liquids.Easily replaced filter cartridges remove solids to 5 microns in the firststage and liquids and solids to .03 microns in the second stage.

SpecificationsInlet Pressure – 80 to 125 psigMaximum Inlet Temperature – +125°FDew Point – See chart for typical conditions – page 12. The lower theoutlet flow, the lower the dew point.Medium – Compressed airOutput Flow Capacity – See chart for typical conditions – page 12Purge Flow – See chart for typical purge flow – page 12Air Connections – Inlet and outlet – 1/4" NPT FemaleMounting – Mount unit with tanks vertical; four mounting holesDimensions – 24" x 14" x 6" – See drawing page 12Electric Motor and Solenoid Valve – 120 volts/ 60 hz/single phase/15 wattsElectric Connections – Terminal stripFilter Rating – Removes 99.99998% of all solid and liquid particles.03 microns and larger.Weight – Approximately 43 pounds

Recommended Operation• The filters are equipped with automatic float drains. Make provision

to collect the discharged liquid in a suitable location. There are 1/8"NPT connections in the bottom of each filter.

• The dryer system works best if the compressed air provided is pre-dried in a refrigeration type air dryer (35 to 50°F pressure dew point).

• The dryer can be continuously operated.• The output air pressure/flow has a momentary pulse as the solenoid

valve switches flow (every 30 sec.). To reduce the pulsation, installa check valve and accumulator (see page 13) at the outlet of theair dryer.

Ordering InformationMax Flow Rate (scfm) Purge Flow Rate (scfm)

Part Number 80 psig Supply 80 psig SupplyOKC-416B-1 2.0 .35OKC-416B-2 3.4 .68OKC-415B-1 6.0 1.2OKC-415B-2 9.0 1.8OKC-415B-3 13.0 2.6

Standard Air Dryer System10

ELECTRIC OPERATION

Air dryer systems consist of 311C insert module, enclosureand two filters.

Electric motor timer controls solenoid valve for automaticcycling of air dryer system.

FlowControlValve (2)

SSDesiccantTanks (2)

Air In1/4" NPT

Prefilter5 microns

CoalescingFilter.03 micron

Air Out 1/4" NPT

Timer

Muffler

SolenoidValve

Page 69: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

DescriptionSeries 141/142 air dryer system has the unique feature of not requiringelectric power for operation. Pneumatic timers and air operated relaysare used for automatic control of the self-regenerative air dryer system.This pneumatic controlled air dryer can be installed in compressed airlines to decrease the dew point to -50°F. A prefilter and coalescing filterboth equipped with automatic drains are standard components of thesystem.

SpecificationsInlet Pressure – 80 to 125 psigMaximum Inlet Temperature – +125°FDew Point – See chart for typical conditions – page 12. The lower theoutlet flow, the lower the dew point.Medium – Compressed airOutput Flow Capacity – See chart for typical conditions – page 12Purge Flow – See chart for typical purge flow – page 12Air Connections – Inlet and outlet – 1/4" NPT FemaleMounting – Mount unit with tanks vertical; four mounting holesDimensions – 24" x 14" x 6" – See drawing page 12Control Pressure – Regulator preset to 50 psig. All connectionsinternal.Filter Rating – Removes 99.99998% of all solid and liquid particles.03 microns and larger.Weight – Approximately 43 pounds

Recommended Operation• The filters are equipped with automatic float drains. Make provision

to collect the discharged liquid in a suitable location. There are1/8" NPT connections in the bottom of each filter.

• The dryer system works best if the compressed air provided is pre-dried in a refrigeration type air dryer (35 to 50°F pressure dew point).

• The dryer can be continuously operated.• The output air pressure/flow has a momentary pulse as the solenoid

valve switches flow (every 30 sec.). To reduce the pulsation, installa check valve and accumulator (see page 13) at the outlet of theair dryer.

• The two timers are preset for periods of 30 seconds each. Theseshould never be changed.

Ordering InformationMax Flow Rate (scfm) Purge Flow Rate (scfm)

Part Number 80 psig Supply 80 psig SupplyOKC-142C-1 2.0 .35OKC-142C-2 3.4 .68OKC-141C-1 6.0 1.2OKC-141C-2 9.0 1.8OKC-141C-3 13.0 2.6

PNEUMATIC OPERATION

Standard Air Dryer System 11

Air timers and air relays automatically cycle the self-regenerating air dryer.

Air operated air dryer system does not require anyelectric power.

CoalescingFilter.03 micron

Air Out 1/4" NPT

AirTimers

RelayValves

PowerValve (2)

Air In1/4" NPT

Prefilter5 microns

SSDesiccantTanks (2)

Muffler (2)

FlowControlValve (2)

TimerRegulator

Page 70: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Standard Air Dryer System12

DIMENSIONS

For Both Pneumatic and Electric Operation

*Series

(4) 5/16" Dia. Mtg. Holes

12"

1/4" NPTOutlet

Oil/WaterRemoving Filter

C

B

Prefilter

A

1/4"NPTInlet

6-1/4"14-1/4"

16-1

/4"

16-3

/4"

Parts for Standard Air Dryer SystemsDescription Qty./Air Dryer Part NumberMuffler for 141C/142C 2 APC-246-2Muffler for 415B/416B 1 OKC-780Desiccant Tank for 141C/142C/415B/416B 2 OKC-777Prefilter Assembly for 142C/416B 1 OKC-740Prefilter Assembly for 141C/415B 1 OKC-730Prefilter Replacement Cartridge for 142C/416B 1 OKC-742Prefilter Replacement Cartridge for 141C/415B 1 OKC-732Coalescing Filter Assembly for 142C/416B 1 OKC-740Coalescing Filter Assembly for 141C/415B 1 OKC-731Coalescing Filter Cartridge for 142C/416B 1 OKC-742Coalescing Filter Cartridge for 141C/415B 1 OKC-733Flow Control Valve For 416B-1; 142C-1 2 Y4F-16-BR-DE For 416B-2; 142C-2 2 Y4F-22-BR-DE For 415B-1; 141C-1 2 Y4F-31-BR-DE For 415B-2; 141C-2 2 Y4F-39-BR-DE For 415B-3; 141C-3 2 Y4F-46-BR-DETimer for 415B/416B 1 OKC-781Timer for 141C/142C 2 OKC-893Solenoid Valve for 415B/416B 1 OKC-779Power Valve for 141C/142C 2 OKC-892Relay Valve for 141C/142C (Detent) 1 OKC-894Relay Valve for 141C/142C (Spring Return) 1 OKC-1220Pressure Regulator for 141C/142C 1 OKC-1222Pressure Gage for 141C/142C 1 OKC-1221

Operating Conditions for Standard Air Dryer SystemsSeries *-16 *-22 *-31 *-39 *-46Inlet pressure – PSIG 80 80 80 80 80Inlet temperature –°F 70 70 70 70 70Purge Flow – SCFM .35 .68 1.2 1.8 2.6Outlet Flow – SCFM 2.0 1.4 1.2 3.4 2.7 2.2 6.0 4.8 4.0 9.0 7.2 6.0 13.0 10.4 8.8Atmos. Dew Point –°F -50 -60 -65 -50 -60 -65 -50 -60 -65 -50 -60 -65 -50 -60 -65Dew Point @ 80 PSIG –°F -18 -30 -35 -18 -30 -35 -18 -30 -35 -18 -30 -35 -18 -30 -35

Dimensions – In.Series A B C

OKC-141C 6.37" .98" 3.35"

OKC-142C 5.60" .90" 3.00"

OKC-415B 6.37" .98" 3.35"

OKC-416B 5.60" .90" 3.00"

Page 71: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

AIR RESERVOIRS

Compressed Air Accumulators 13

DescriptionCompressed air accumulators serve to reduce or eliminate pulsationwhich occurs twice in each cycle of twin tower, self-regenerativecompressed air dryers. The accumulators are complete with an inletcheck valve, a 125 psig relief valve, and an output pressure regulator.

The portable 20 gallon unit can also be used as a storage tank for clean,dry compressed air. Usable for low flow requirements at a remotelocation that does not have a compressed air source.

Applications• Pulse reduction in cyclic air dryer system.• Pressure regulation in precision pneumatic systems.• Portable air source for temporary low flow requirements.

SpecificationsStorage Volume – Series 2055 – 3 gallon

– Series 2054 – 20 gallonMaximum Pressure – 125 psigRelief Valve Setting – 125 psigTank Material – SteelDimensions – See drawing.Output Pressure Regulator – Adjustable – see range in chart below.ASME Code – Series 2054 only.Connections – 1/4" NPT

Ordering InformationOutput Gage

Pressure Regulator Range 3 Gallon 20 Gallon (psig) Type (psig)OKC-2055-1 OKC-2054-1 0-125 General Purpose 0-160OKC-2055-2 OKC-2054-2 0-125 Precision 0-160OKC-2055-3 OKC-2054-3 0-100 Precision 0-100OKC-2055-4 OKC-2054-4 0-60 Precision 0-60OKC-2055-5 OKC-2054-5 0-30 Precision 0-30OKC-2055-6 OKC-2054-6 0-20 Precision 0-20OKC-2055-7 OKC-2054-7 0-10 Precision 0-15OKC-2055-8 OKC-2054-8 0-2 Precision 0-3

Custom AssembliesA variety of tank sizes and styles are available for pressures up to125 psig. The tanks can be equipped with check valves, relief valves,filters, pressure regulators or gages as required. Consult factory withyour requirements.

3 gallon accumulator includes check valve, relief valve andoutput pressure regulator with gage.

Accumulator reduces pressure surges caused by cycling airdryer system, or sudden output flow changes.

Portable 20 gallon tank can provide clean, dry compressedair to a remote location.

AirIn

13 3/8"AirOur

Relief ValveCheck Valve

25 1/4"(4) 1/2" Dia. Mtg. Holes

3 Gallon Tank

DrainValve

Regulator

20 gallon accumulator is portable. Semi-pneumatic tires andhandle are standard.

CheckValve

Drain Valve

20 Gallon Tank

Relief ValveRegulator

Air In

AirOut 22 7/8"

40 1/2"31 1/2"

Page 72: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

High Flow Air Dryer Module14

20 SCFM • QUIET OPERATION

DescriptionThe series 2042 high flow air dryer will handle up to 20 scfm at supplypressure of 80 to 125 psig. Using a solid state timer, three power valvesare sequenced to provide the following features:• Quiet operation – No large pressure surge during switching.• Virtual pulse free output pressure – No significant pressure swing

during switching.• Three models rated at 10, 15 and 20 scfm respectively.

Construction is simplified and cost is reduced using an open frameassembly for this series. All electric components are housed in a smallNema 12/13 enclosure. Valves and desiccant tanks are plate mounted.

SpecificationsInlet Pressure – 80 to 125 psigMaximum Inlet Temperature – +125°FDew Point – minus 50°F atmospheric at maximum rated flow;dew point decreases at flow rates less than maximum.Medium – Clean oil-free compressed air.Output Flow Capacity – 10, 15 or 20 scfm – See chart below.Purge Flow – See chart below.Air Connections – 1/2" NPT or 1/2" OD plastic tubing.Mounting – Mount unit vertical and upright; six mounting holes.Dimensions – 33" x 21" x 7" – See drawing page 16.Electric Connections – Terminal strip inside enclosure.Required Filtration – Prefilter – 5 micron

Coalescing filter – .01 micronWeight – Approximately 60#.

Recommended Operation• The 2042 series air dryer has protected electrical connections and

can be field mounted.• Always provide clean air to the dryer. Use a prefilter (OKC-2046) to

remove solid contamination and a coalescing filter (OKC-2047) toremove liquid water and oil.

• The dryer can be continuously operated.

Ordering InformationMax Flow Purge Flow

Rate Rate Atmos. Pressure (scfm) (scfm) Dew Point Dew Point

Part Number @ 80 psig @ 80 psig °F . °F .OKC-2042-1 10 2 -50 -18OKC-2042-2 15 3 -50 -18OKC-2042-3 20 4 -50 -18

Open frame air dryer module can handle up to 20 scfm at80 psig and deliver an output dew point of -50°F atmospheric.

Air dryer employs a solid state timer, three power valves andtwo tanks of desiccant to achieve low dew point.

Flow Control Valves (2)

Timerand

SolenoidValvesInside

ConnectElectricPower120/60

Muffler

PowerValve (3)

Des

icca

nt T

ank

Des

icca

nt T

ank

Page 73: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

PULSE FREE

High Flow Air Dryer System 15

DescriptionThe series 2043 high flow air dryer system handles up to 20 scfm atsupply pressure of 80 to 125 psig. Using a solid state timer, three powervalves are sequenced to provide the following features:• Quiet operation – No large pressure surge during switching.• Virtual pulse free output pressure – No significant pressure swing

during switching.• Three models rated at 10, 15 and 20 scfm respectively.

The air dryer is housed in a Nema 12/13 enclosure and a prefilter andcoalescing filter are attached externally. The system can handle substan-tial air flows without attracting attention or creating noise disturbances.

SpecificationsInlet Pressure – 80 to 125 psigMaximum Inlet Temperature – +125°FDew Point – minus 50°F atmospheric at maximum rated flow;dew point decreases at flow rates less than maximum.Medium – Clean compressed air.Output Flow Capacity – 10, 15 or 20 scfm – See chart below.Purge Flow – See chart below.Air Connections – 1/2" NPTMounting – Mount unit vertical and upright; four mounting holes.Dimensions – 36" x 24" x 7" – enclosure only – See drawing page 16.Electric Connections – Terminal strip on timer sub-plate.Filtration – Prefilter with auto drain – 5 micron

Coalescing filter with auto drain – .01 micronWeight – Approximately 120#.

Recommended Operation• The filters are equipped with automatic float drains. Make provision

to collect the discharged liquid at a suitable location. There are1/8" NPT connections at the bottom of each filter.

• The dryer system works best if the compressed air provided is pre-dried in a refrigeration type air dryer (35 to 50°F pressure dew point).

• The dryer can be continuously operated.

Ordering InformationMax Flow Purge Flow

Rate Rate Atmos. Pressure(scfm) (scfm) Dew Point Dew Point

Part Number @ 80 psig @ 80 psig °F . °F .OKC-2043-1 10 2 -50 -18OKC-2043-2 15 3 -50 -18OKC-2043-3 20 4 -50 -18

External filters remove solids and liquids from compressedair. The dryer removes water vapor from the air.

A solid state timer sequences the three power valves to assurequiet, pulse-free operation.

Flow Control Valves (2)

Air

Out

SolidStateTimer

PilotValves

(3)

MufflerPowerValve

(3)

CoalescingFilter

Prefilter

Air

In

Des

icca

nt T

ank

Des

icca

nt T

ank

Page 74: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

High Flow Air Dryers16

DIMENSIONS

7.00

8.50

.44

Dim. – In.

11.00

9.19

1/2" NPT – Air In

3.00.44 Dia. – Mtg. Holes

24.00

4.25

1/2" NPTAir Out

36.00

37.20

18.00

ModuleSeries 2042

SystemSeries 2043

21.00Dim. – In.

(6) .50 Dia. Mtg. Holes

.88 Typ.

.88Typ.

33.00

16.50

Parts for High Flow Air DryersDescription Qty./Air Dryer Part NumberTimer for 2042; 2043 (120/60) 1 OKC-1150-2Solenoid Valve for 2042; 2043 (120/60) 3 OKC-2050-2Check Valve for 2042; 2043 1 FFLC-2-BRFlow Control Valve For 2042-1; 2043-1 2 Y6F-41-BR-DE For 2042-2; 2043-2 2 Y6F-52-BR-DE For 2042-3; 2043-3 2 Y6F-60-BR-DEMuffler for 2042; 2043 1 OKC-2051Desiccant Tank for 2042; 2043 2 OKC-2052Power Valve for 2042; 2043 3 OKC-2049Prefilter for 2043 1 OKC-2046Prefilter Cartridge for 2043 1 OKC-732Coalescing Filter for 2043 1 OKC-2047Coalescing Filter Cartridge for 2043 1 OKC-733Autodrain Assembly for 2043 2 OKC-734

Page 75: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

DEW POINT REDUCTION

Point-of-Use Air Dryer System 17

DescriptionThe "point-of-use" compressed air dryer re-moves liquid water using filters; and reducesthe pressure dew point of the air throughpressure reduction. The system consists of aprefilter and a coalescing filter, followed bya pressure regulator. Two gages and mount-ing hardware are included in the system.Maximum flow rates of 10, 20 and 40 scfmare available as standard.

While depression of dew point with thesystem is not as dramatic as in desiccant airdryers, it is an economical approach to solv-ing local in-plant air line water problems.

How It Works!Assume that the air entering the filters con-tains liquid water and water vapor at 100%relative humidity. The air exiting the filtersis virtually free of liquid water, but is still at100% relative humidity as it enters the pres-sure regulator.

Since pressure regulators reduce pressure,there is a corresponding decrease in thedensity of the air at the exit from the regula-tor. Not only is the density of the air reduced,but also that of the water vapor, resulting ina decrease of the relative humidity. Satu-rated water vapor entering the regulator is nolonger saturated in the reduced pressure atthe outlet.

The dew point chart (at right) illustrates thereduction of dew point that can be achieved.The lower the outlet pressure of the regulatorthe lower is the relative humidity and associ-ated dew point. The assumption for the chartdata is that heat transfer maintains the tem-perature reasonably constant during flowpassage through the pressure regulator.

Where To Use the Air Dryer!Install this dryer close to the "point of use" toinsure that there is no substantial tempera-ture decrease between the regulator anddownstream use point.

It is good practice to maintain the regulatoroutput pressure a minimum of 20 psi belowthe regulator input pressure. The two gagesprovided are for this purpose.

SpecificationsMedia – Compressed airConnections – Process – 1/4", 3/8" or 1/2" NPT Drains – 1/8" NPT maleInlet Pressure Range – 80-150 psigInlet Temperature Range – +40 to 125°FMaximum Flow Rate – up to 40 scfmConsult factory for larger flow rates.Outlet Pressure Range – 1-150 psigFiltration – .01 micron through dual filters.Liquid Drains – Automatic float ineach filter. 1/8" NPT connection.Mounting – Integral brackets;See dimension drawing.Dimensions – See drawing and chart.Filter Elements – ReplaceableMaterials of Construction –

Filter Bowl – PolycarbonateFilter Body – ZincRegulator Body – ZincBowl Guard – Aluminum

Dew Point ChartPoint-of-Use Air DryerRegulator Inlet Air Conditions• 100 psig, 70°F, 100% RH• Contains no condensate• Barometric pressure 14.7 psia

Output Relative PressurePressure Humidity Dew Point

psig % °F100 100 70.090 91.0 67.380 82.6 64.570 73.8 61.260 65.1 57.750 56.4 53.940 47.7 49.530 39.0 44.020 30.3 37.510 21.5 29.00 12.8 16.5

Ordering Information Part Maximum Connections Number Flow – SCFM NPTOKC-2039-1 10 scfm 1/4"OKC-2039-2 20 scfm 3/8"OKC-2039-3 40 scfm 1/2"

AB

C

DInletNPT

OutletNPT

Filters remove condensate before airenters regulator. Regulator reducesoutlet pressure and the dew point dropsaccordingly.

Dimensions

Type A B C D NPT

OKC-2039-1 10-5/8" 4-5/8" 3" 7-1/2" 1/4"

OKC-2039-2 11-3/4" 4-15/16" 3" 8-1/4" 3/8"

OKC-2039-3 11-3/4" 4-15/16" 3" 8-1/4" 1/2"

Coalescing Filter

Prefilter

PressureRegulator

OutletPressure

Gage

InletPressure

Gage

(2) MountingBrackets

1/8" NPT -Male (2)

Point-of-use air dryer contains two filters,two pressure gages and one regulator.

Page 76: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Air Dryer Accessories18

IN-LINE FLOWMETERS WITH PRESSURE GAGE – AIR SERVICE

Calibrated for Inlet Pressures 40-100 psig • Vertical or Horizontal ➝➝➝➝➝ Mounting

Pipe Size Flow Range Approximate Inlet MaximumPart No.* Female NPT SCFM to Outlet Dim. HeightOKC-1000-1 1/4" 1-4 6-3/4" 4-1/4"OKC-1000-2 1/4" 2-9 6-3/4" 4-1/4"OKC-1000-3 1/4" 2-18 6-3/4" 4-1/4"OKC-1000-5 1/2" 2-20 9-1/4" 4-3/4"OKC-1000-6 1/2" 10-60 9-1/4" 4-3/4"OKC-1000-10 3/4" 5-50 10-1/2" 5-1/4"OKC-1000-11 3/4" 10-90 10-1/2" 5-1/4"

*Maximum Pressure 150 psig; Maximum Temperature 150°F

Calibrated for Standard Atmospheric Conditions • Vertical Mounting Only

Air Flow Range Dimensions MaximumPart No.* (SCFH) Overall Height Scale Length Connection PressureKRMA-1 .05 - .5 4-9/16" 2" 1/8" NPT 100 psigKRMA-3 .2 - 2 4-9/16" 2" 1/8" NPT 100 psigKRMA-5 1-10 4-9/16" 2" 1/8" NPT 100 psigKRMB-52 5-50 8-1/2" 5" 1/4" NPT 70 psigKRMB-54 20-200 8-1/2" 5" 1/4" NPT 70 psigKRMC-104 40-400 15-1/8" 10" 1/2" NPT 35 psigKRMC-106 100-1000 15-1/8" 10" 1/2" NPT 35 psigKRMC-108 180-1800 15-1/8" 10" 1/2" NPT 35 psig

*Maximum Temperature 130°F

Part No. Output SupplyPart No.* With Gage Size Pressure (max.) DimensionsOKC-1045-1 OKC-1045-1G 0-2 psigOKC-1045-2 OKC-1045-2G 0-10 psig Inlet toOKC-1045-3 OKC-1045-3G 1/4" 0-20 psig

400 psigOutlet <3"

OKC-1045-4 OKC-1045-4G NPT 0-30 psigOKC-1045-5 OKC-1045-5G 0-60 psig HeightOKC-1045-6 OKC-1045-6G 0-160 psig 6-1/2" max.

*Maximum Pressure 150 psig; Maximum Temperature 150°F

➝➝➝➝ ➝

➝➝➝➝ ➝

PRECISION AIR PRESSURE REGULATORS

FLOW METERS – AIR SERVICE – ROTAMETER STYLE

Page 77: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

MOISTURE INDICATORS

Air Dryer Accessories 19

CHEMICAL DRYERS

FINE AIR FILTERS

PRESSURE GAGES

13.00"

4.62"

2.73"

5.53"

PIPE

These moisture indicators contain silica gel. Moist air with a dew point greater than 4°F will cause the color to change from blue to pink(or clear). When dry air (less than 4°F) flows through the indicator the blue color is restored.

Part No. OKC-1739 Part No. OKC-1015 Part No. OKC-2038Connections – Connections – 1/2" NPT Female Connection – 1/4" NPT Inlet – 1/2" - 20 (O-Ring Seal) Flow – In Line (no trace flow) Trace Air Flow – 2 scfh Outlet – Flow to Atmos. Max. Flow – 15 scfm Mounting – Vertical/UprightTrace Air Flow – 2 scfh @ 100 psig Mounting – Vertical/Upright Media – Oil-free airMounting – Vertical/Upright Media – Oil-free air Max. Pressure – 125 psigMedia – Oil-free air Max. Pressure – 100 psigMax. Pressure – 125 psig

LINE TEE IN-LINE REMOTE

Part No. OKC-2037-1 Part No. OKC-2037-2This dryer will remove moisture from This dryer will remove moisture fromcompressed air up to a total of 4400 compressed air up to a total of 600standard cubic feet per the following standard cubic feet per the followingspecifications. specifications. Inlet Pressure – 100 psig Inlet Pressure – 100 psig Maximum Flow – 10 scfm Maximum Flow – 5 scfm Atmos. Dew Point – minus 45°F Atmos. Dew Point – minus 45°F Desiccant – Silica Gel Desiccant – Silica GelConnections are 1/4" NPT Female Connections are 1/4" NPT Female

The desiccant when saturated must be replaced. Silica gel changes color fromblue to pink as the material becomes saturated.

The application for this dryer is for low flow requirements or for higherflow situations which operate only occasionally.

Connection Micron Dimensions Max. Flow Max.Part No.** Size Rating Drain W H SCFM Pressure*OKC-1379 1/4" NPT 5 Manual 1.5" 3.6" 3 150 psigOKC-1380 1/4" NPT .01 Manual 1.5" 3.6" 3 150 psigOKC-739 1/4" NPT 5 Auto 3.0" 7.5" 10 150 psigOKC-740 1/4" NPT .01 Auto 3.0" 7.5" 10 150 psigOKC-730 1/4" NPT 5 Auto 3.3" 8.2" 20 150 psigOKC-731 1/4" NPT .01 Auto 3.3" 8.2" 20 150 psig

*Maximum Operating Temperature 125°F**Filter bowls are polycarbonate. Metal bowl guard included.

BOTTOM MOUNT BACK MOUNTPart Pressure Part Pressure

Number Range (psig) Number Range (psig)OKC-2035-1 0-5 OKC-2036-2 0-15OKC-2035-2 0-15 OKC-2036-3 0-30OKC-2035-3 0-30 OKC-2036-4 0-60OKC-2035-4 0-60 OKC-2036-5 0-100OKC-2035-5 0-100 OKC-2036-6 0-160OKC-2035-6 0-160

Bottom mount pressure gages have Back mount pressure gages have2-1/2" dial; 1/4" NPT brass connection. 2" dial; 1/4" NPT brass connection.

Trace Flow1-1/2"Dia.

Thread 1/2-20(O-Ring Seal)

11/16"Hex

2-1/2"

H

W

1-1/2"

AirIn

TraceFlow

3-1/2"

3"Dia. AirOut

1/2" NPT

1/2" NPTAirIn

7-3/8"

Page 78: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Automatic Drain Valves20

TIMED RELEASE

DescriptionThe Automatic Timed Solenoid Valve is a combination of a brass bodydirectional control valve and an attached electronic repeat cycle timerwhich alternately opens and closes the valve. The valves are industrialquality, suitable for air or water service. The timer has an off time period(valve de-energized) that is adjustable from 1 - 45 minutes. The on timeperiod (valve energized) is adjustable from 1 - 15 seconds. A touchbutton manual override on the electronic timer allows for manualcontrol of the valve.

ApplicationsThe Automatic Timed Solenoid Valve can be used to discharge watercollected in tanks, pipes, filters or refrigeration dryers in compressed airsystems. The valve opens periodically for a short duration and dis-charges collected water into a drain or sump.

The valve can also be used to periodically spray water for cooling orwetting of produce, vegetation, or equipment.

General SpecificationsElectronic TimerVoltage – 120 voltsFrequency – 60 hzEnergize Time – 1-15 secondsDe-energize Time – 1-45 minutesManual Override – Touch buttonPower On Light – LED • RedValve Energized Light – LED • GreenAmbient Temperature – +32° to 125°FPower Output to Valve – 20 watts maxConnections – DIN Size 30/40Enclosure Protection – Equivalent to Types 1 and 4Housing Material – Polycarbonate

Solenoid ValvesMaterials – Brass Body • BUNA N SealsCompatible Fluids – Air, WaterPressure & Flow (Cv) – See chart on page 21Power – Less than 20 wattsVoltage/Frequency* – 120/60Enclosure – Types 1, 2, 3, and 4Ambient Temperature – +32° to 125°FConnections – Female Pipe Threads

Timed Solenoid Valve

Timing Diagram

VIEW AROTATED 180°

Energize Time{1 - 15 Seconds

DwellTime

1 - 45 Minutes

ValveEnergized

ValveDe-energized

Electronic TimerManualOverrideTouch Button

Green LightOn WhenValve IsEnergized

AdjustmentFor DurationThat ValveIs Energized

Adjustment ForDwell Time.Valve IsDe-energizedDuring DwellTime.

Power OnLight (Red)

Page 79: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

ADJUSTABLE TIMING

Automatic Drain Valves 21

Dimensions

Pipe Differential Fluid Cv CoilPart Number* Size Type Pressure PSIG Temp. Flow Watt

(In.) Min. Max. Max – °F Factor Rating

OKC-821/1G212 1/4 N.C. 0 100 180 .88 17.1

OKC-821/1G262 1/4 N.O. 0 100 180 .35 10.1

OKC-821/100G1 3/8 N.C. 5 150 180 3.0 6.1

OKC-821/10G93 3/8 N.C. 0 150 180 3.0 10.1

OKC-821/10G33 3/8 N.O. 0 150 180 3.0 10.1

OKC-821/100G2 1/2 N.C. 5 150 180 4.0 6.1

OKC-821/10G94 1/2 N.C. 0 150 180 4.0 10.1

OKC-821/10G34 1/2 N.O. 0 150 180 4.0 10.1

OKC-821/100G3 3/4 N.C. 5 150 180 6.5 6.1

OKC-821/10G95 3/4 N.C. 0 150 180 5.0 10.1

OKC-821/10G35 3/4 N.O. 0 150 180 5.5 10.1

OKC-821/100G4 1 N.C. 5 150 180 13 6.1

OKC-821/100G8 1-1/4 N.C. 5 150 180 15 6.1

OKC-821/10G22 1-1/2 N.C. 5 150 180 22 6.1

OKC-821/1G100 2 N.C. 5 125 180 43 6.1

Dimension Chart

Valve SelectionSelect a valve for the application compatible with the pressureand flow requirements. For draining gravity pressurized vesselsselect a valve with a minimum pressure differential rating of"0" psig. Such a valve will operate even at low liquid levels inthe vessel.

Optional Power Cord (120 volts/60 hz)

A six foot long power cord with a 3-prong plug for 120 volts/60 hzhas a DIN connector for attaching to the timer. Part No. OKC-822.

Options AvailableConsult the factory for any of the following options.Voltage – 24/60 or 240/60Materials – Stainless Steel Body or Alternate Valve SealsSlow Closing Construction – to avoid water hammerOther Fluids – steam, deionized water, or chemicals

PipePart Number Size Type H L L1 P W W1

(In.)

OKC-821/1G212 1/4 N.C. 3-29/32 1-9/16 3-13/32 3-9/32 — 1-31/32

OKC-821/1G262 1/4 N.O. 3-3/4 1-1/4 DIA. 3-1/2 3-11/32 — 1-31/32

OKC-821/100G1 3/8 N.C. 3-3/4 2-3/4 2-5/8 3-3/16 2-5/16 —

OKC-821/10G93 3/8 N.C. 4-3/8 2-3/4 2-13/16 3-13/16 2-5/16 —

OKC-821/10G33 3/8 N.O. 4-13/16 2-3/4 2-13/16 4-1/4 2-9/32 —

OKC-821/100G2 1/2 N.C. 3-3/4 2-3/4 2-5/8 3-3/16 2-5/16 —

OKC-821/10G94 1/2 N.C. 4-3/8 2-3/4 2-13/16 3-13/16 2-5/16 —

OKC-821/10G34 1/2 N.O. 4-13/16 2-3/4 2-13/16 4-1/4 2-9/32 —

OKC-821/100G3 3/4 N.C. 4-1/2 3-25/32 2-1/8 3-7/8 2-3/4 —

OKC-821/10G95 3/4 N.C. 4-19/32 2-13/16 2-25/32 3-29/32 2-5/16 —

OKC-821/10G35 3/4 N.O. 5-3/32 2-13/16 2-25/32 4-15/32 2-9/32 —

OKC-821/100G4 1 N.C. 5-31/32 3-3/4 2-1/8 4-11/32 2-15/16 —

OKC-821/100G8 1-1/4 N.C. 5-31/32 3-21/32 2-5/32 4-11/32 3-3/8 —

OKC-821/10G22 1-1/2 N.C. 6-15/32 4-3/8 1-13/16 4-1/2 3-3/4 —

OKC-821/1G100 2 N.C. 7-21/32 5-1/16 1-15/32 4-29/32 4-11/16 —

Dimensions – In.

Ordering InformationThe part numbers shown in the valve specifications chart includean assembly consisting of a valve and a timer, e.g., Part NumberOKC-821/100G2 consists of the timer and a 1/2" NPT normallyclosed solenoid valve: both operating at 120 volts/60 hz.

To order the timer/valve assembly operating at 120 volt/60 hz usethe part number selected from the valve specification chart.

To order the six foot long power cord for operation at 120 volts/60 hz specify part number OKC-822.

To order a timer only specify part number OKC-821.

Valve SpecificationsBrass Body • Buna-N Seals Part Number Includes

Timer and Valve

*Above part numbers for 120 Volts/60 hz

Page 80: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

Pneumatic Controls22

CHECK VALVES / FIXED FLOW CONTROLS

Ball type check valves are produced in three sizes: 10-32, 1/8" NPT and1/4" NPT. They are available in brass or stainless steel and are suitablefor use with liquids or gases. Free flow occurs in one direction only;reverse flow is prevented.

Standard units are used at pressures up to 200 psig. The high pressureversion can operate up to 2000 psig. See chart of characteristics at right.For additional details request Brochure OK-253.

Pipe FreeSize End Cracking Body Disk Maximum Flow

Type Construction NPT Connections Pressure Material Material Pressure Cv

DOC 1/8" male/female Brass(BR) .43

GOC 1/4" male/female Brass 303 SS(BR) (SS) .61

Y2C 1/8" female/female 0 or or 150 psig.43

303 SS DelrinY4C 1/4" female/female (SS) (DE)

.61

Y6C 3/8" female/female1.09

Disk type check valves are produced in three sizes: 1/8" NPT,1/4" NPT and 3/8" NPT. They are available in brass or stainless steel andare suitable for use with liquids or gases. Free flow occurs in onedirection only; reverse flow is prevented.

Disk check valves feature high flow capacity. Only one moving part isrequired. See chart of characteristics at right. For additional detailsrequest Brochure OK-256.

These fixed flow controls are a parallel arrangement of a ball check valveand a precision orifice. Free flow occurs in one direction and meteredflow occurs in the opposite direction. Suitable for both liquids and gasesthe fixed flow controls are available in brass or stainless steel.

Standard units are used at pressures up to 200 psig. The high pressureversion can operate up to 2000 psig. See chart of characteristics at right.For additional details request Brochure OK-253.

These fixed flow controls are a parallel arrangement of a disk check valveand a precision orifice. Free flow occurs in one direction and meteredflow occurs in the opposite direction. Suitable for both liquids and gasesthe fixed flow controls are available in brass or stainless steel.

Pressure is limited to 150 psig. Flow capacity is large. Available in1/8" NPT, 1/4" NPT and 3/8" NPT. See chart of characteristics at right.For additional details request Brochure OK-256.

Cracking BodyType Pressure Material Part NumberFFLC 2 BR FFLC-2-BR (standard pressure)

Examples BLC 10 SS BLC-10-SS (standard pressure)ELCH 15 BR ELCH-15-BR (high pressure)

Ordering Information – Ball Type Check Valves

Use delrin disk for air and inert gasesCracking Body Disk

Type Pressure Material Material Part NumberExamples GOC - 0 - SS - DE GOC-0-SS-DE

(1/4" male/female) (303 SS) (Delrin)Y6C - 0 - BR - BR Y6C-0-BR-BR

(3/8" female/female) (Brass) (Brass)

Ordering Information – Disk Type Check Valves

Orifice Cracking BodyType Size No. Pressure Material Part NumberFFLF 10 10 BR FFLF-10-10-BR (standard pressure)

Examples BLFH 25 15 SS BLFH-25-15-SS (high pressure)ELF 60 2 SS ELF-60-2-SS (standard pressure)

Ordering Information – Ball Type Fixed Flow Controls

Use delrin disk for air and inert gasesOrifice Body Disk

Type Size No. Material Material Part NumberExamples GOF - 10 - SS - SS GOF-10-SS-SS

(1/4" male/female) (.010" orifice) (303 SS) (303 SS)Y6F - 22 - BR - DE Y6F-22-BR-DE

(3/8" female/female) (.022" orifice) (Brass) (Delrin)

Ordering Information – Disk Type Fixed Flow Controls

Pipe Metering FreeSize End Orifice Body Disk Maximum Flow

Type Construction NPT Connections Size No. Material Material Pressure Cv

DOF 1/8" male/female 4 to 125 Brass .43 to(BR) .51

GOF 1/4" male/female 4 to 125 Brass 303 SS .61 to(BR) (SS) .98

Y2F 1/8" female/female 4 to 125 or or 150 psig .43 to.51

303 SS DelrinY4F 1/4" female/female 4 to 125 (SS) (DE) .61 to

.98

Y6F 3/8" female/female 4 to 125 1.09 to1.46

orifice

orifice

Disk Type Fixed Flow Controls

Ball Type Fixed Flow Controls

† High pressure type use suffix H

Air Free Flow Max. Pressure Max.Free Inlet - 100 psig Standard High Cracking LiquidFlow Outlet – atmos. (Suffix H)† Pressure Flow BodyCv scfh psig psig psid gpm Materials

0, 2 Brass.081 331 125 — or .80 or

10 SS

0, 2 Brass.081 331 200 2000 or 1.1 or

10 SS

0, 2 Brass.225 951 200 2000 or 3.2 or

15 SS

TypeFFLC10-32thread

TypeBLC,BLCH1/8" NPT

TypeELC,ELCH1/4" NPT

Construction

Ball Type Check Valves

Disk Type Check Valves

Air Free Flow Max. Pressure Max.Free Inlet - 100 psig Standard High Cracking LiquidFlow Outlet - atmos. (Suffix H)† Pressure Flow BodyCv scfh* psig psig psid gpm Materials

.084 346 0, 2 .84 Brassto to 125 — or to or

.162 662 10 1.62 SS

.084 346 0, 2 1.2 Brassto to 200 2000 or to or

.162 662 10 2.3 SS

.228 950 0, 2 3.2 Brassto to 200 2000 or to or

.425 1767 15 6 SS

TypeFFLF10-32thread

TypeBLF,BLFH1/8" NPT

TypeELF,ELFH1/4" NPT

Construction

† High pressure type use suffix H

Page 81: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 2001 ALL RIGHTS RESERVED e-mail [email protected] • website www.okcc.com

SENSORS

Pneumatic Controls 23

Pneumatic Pressure SwitchThe Pneumatic Pressure Switch combines apressure sensing element and a spool valve toproduce a switching device with an adjustableset point. The assembly is non-electric, usingonly air or inert gas in the switch unit.

The pressure sensor is compatible with air,water, steam, oil and many corrosive liquids or

gases. Setpoint is adjustable – vacuum up to 6000 psig.

Air signals from the 5 ported 4-way valve in the switch unit can beeither vacuum or positive pressure up to 100 psig. RequestBulletin OK-043.

Pneumatic Liquid Level SwitchThe Liquid Level Switch is an air sensor fordetecting liquid level inside a vessel. The floatmechanism mounted within the vessel oper-ates a ceramic coated magnet. A magneticallyactuated sensor on the outside of the solid

metal housing reacts to the inner magnet move-ment. The movement shifts a 3-way air valve.

Both side mounted (shown here) and top mountedunits are available. Wetted materials are brass or stainless steel.

The magnetic sensor unit operates at air pressure from 30 to 100psig. The 3-way valve signals can pilot alarms or control elements.Request Bulletin OK-242.

Pneumatic Flow SwitchThe Pneumatic Flow Switch is an air sensorfor detecting the flow of liquids or gases in

a pipe. A paddle extends into the fluid and deflectsas the stream velocity increases or decreases.Various sized paddles establish the particularfluid stream flow rate at which the external mag-netic sensor is actuated.

The air sensor is a 3-way valve which operates atpressures from 30 to 100 psig. Flow switch units are available from1/2" to 2" NPT. Wetted materials are brass or stainless steel.Request Bulletin OK-268.

Air Jet Proximity SensorThe Air Jet Proximity Sensor is a non-contact

no-moving-part sensor, capable of detect-ing the presence of an object at rangesup to 1/8". In the absence of an object,

air flows freely from the sensor resultingin a near zero output signal. The presence of an object within thesensing range deflects the normal air flow and results in a positiveoutput signal.

Air supply pressure is 0.5 to 10 psig. Output signals are lowpressure and sufficient to actuate air/electric switches or air/airamplifiers. Request Brochure OK-098.

Pneumatic Temperature SwitchThe Pneumatic Temperature Switch combines atemperature sensing element and a spool valve toproduce a switching device with an adjustable setpoint. The assembly is non-electric, using only air orinert gas in the switch unit.

The temperature sensor is available in direct mount(shown here) or with a bulb and capillary. Wettedmaterials are copper or stainless steel.

Air signals from the 5 ported 4-way valve in theswitch unit can be either vacuum or positive pressure up to100 psig. Request Bulletin OK-088.

Pneumatic Liquid Level IndicatorThe Liquid Level Indicator displays the heightof liquid above the tip of an air tube im-mersed in the liquid. A small amount of airbubbles through the liquid of a vented vessel.The back pressure in the sense tube isdisplayed on a gage. This back pressure

corresponds to the height of the liquid above the top of the sense tube.

Ranges of liquid height vary from 0-1 in. to 0-60 ft. RequestBulletin OK-267.

Differential Pressure Flow SwitchThe Differential Pressure Flow Switch uses a cali-brated flow element to provide pressure signals to anadjustable setpoint differential pressure electric

switch. Gases or liquids can be used. Wettedmaterials are aluminum, brass or stainless steel.

Adjustable flow rate setpoints are available forwater flow ranges from 15-50 sccm to4-12 GPM. Request Bulletin OK-269.

Magnetic Proximity SensorThe Magnetic Proximity Sensor detectsthe presence of a magnetic or steel part inits near vicinity. The 3-way normally closedair valve is actuated when in the presenceof a small magnet or steel part. The valvedeactuates when the small magnet or steel

part is removed.

Since magnetic fields penetrate materials such asaluminum or stainless steel, the proximity sensor readily detects aproperly polarized magnetic piston in a cylinder constructed withaluminum or stainless steel barrels. It is often used in place of limitswitches to detect end of stroke position.

The sensor is available with mounting straps for attachment to around cylinder barrel. Request Brochure OK-248.

Page 82: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Precision Orifices"Over 6000 Choices"

Sapphire, Brass, Stainless Steel

Micro-Orifices®

"Diameter as small as .0003 inch"Brass or Stainless Steel

In-Line Screen Products"Protect Small Orifices"

10 to 100 microns

Miniature Stainless Steel Fittings"Adapters, Bulkheads,

Couplings, Barbs"

Check Valves"Vacuum to 2000 psig"

Brass or Stainless Steel

Fixed Flow Controls"For Cylinder Speed Control"

Brass or Stainless Steel

Pneumatic Sensors"For Pressure, Temperature,

Flow, Level, Proximity"

PRODUCTS MANUFACTUREDBY

O'KEEFE CONTROLS CO.

Fax (203) 261-8331 Toll Free Phone (800) 533-3285 CT Phone (203) 261-6711e-mail [email protected] website www.okcc.com

Mailing Address LocationP.O. Box Q 4 Maple Drive

Trumbull, CT 06611 © O'Keefe Controls Co. 2001 All Rights Reserved Monroe, CT 06468

Page 83: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

Fax (203) 261-8331 Toll Free Phone (800) 533-3285 CT Phone (203) 261-6711Mailing Address LocationP.O. Box Q 4 Maple DriveTrumbull, CT 06611 Monroe, CT 06468

Form OK-240R1website www.okcc.com • e-mail [email protected]

MiniatureStainless Steel

Fittings and Screens

Adapters • Couplings • Nipples • Barbs • Plugs • Bulkheads

1/8”, 1/4”, 1/2” NPT • 1/16”, 1/8” Barbs • 10-32 Threads • Inserts

Barb Fittings • Pipe Fittings • In-Line Screens

Page 84: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 1999 ALL RIGHTS RESERVED e-mail [email protected] • web site www.okcc.com

Miniature Stainless Steel Fittings2

BARB INSERT

BARB ADAPTER

BARB ADAPTER

BARB COUPLING

BARB COUPLING

GENERAL SPECIFICATIONSBarb or 10-32 Connections

Maximum Operating Pressure – 125 psigMaterials of Construction — Body - 303 SS • Seals - Viton

Fluid Media – Air, Water, Gases and Liquids compatible with materials of construction

DimensionsDescription

Part Number T-48-SSFor 1/16" ID Tubing

Part Number N-96-SSFor 1/8" ID Tubing

Part Number W-96-SSFor 1/8" ID Tubing

Part Number M-48-SSFor 1/16" ID Tubing

Part Number TB-52-SSFor 1/16" ID Tubing

Press fit into bore .0730"/.0735"(adhesive recommended)

Barb for 1/16" ID Tubing

3/16" HEX

.625"

.800"1/4" HEX

Barb for 1/8" ID Tubing

10-32 Straight Threads

Barb for 1/8"ID Tubing

.610"

1/4" HEX

Seal

10-32 Straight Threads

Seal

1/4" HEX

.530"

Barb for 1/16" IDTubing

.440"

.150" .020"

0745"/.0755" Dia.

Barb for 1/16" ID Tubing

Page 85: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 1999 ALL RIGHTS RESERVED e-mail [email protected] • web site www.okcc.com

Miniature Stainless Steel Fittings 3

BARB ADAPTER

BARB ADAPTER

10-32 COUPLING

10-32 ADAPTER

10-32 PLUG

GENERAL SPECIFICATIONSBarb or 10-32 Connections

Maximum Operating Pressure – 125 psigMaterials of Construction — Body - 303 SS • Seals - Viton

Fluid Media – Air, Water, Gases and Liquids compatible with materials of construction

DimensionsDescription

Part Number FM-96-SS

Part Number FF-96-SS

Part Number QX-0-SS

Part Number BW-96-SSFor 1/8" ID Tubing

Part Number BT-48-SSFor 1/16" ID Tubing

10-32 ThreadsBoth Ends

.500"

.312" Dia.

Round

.560"

.312" Dia.

10-32Threads

Seal

10-32 ThreadsRound

1/8" NPT

Barb For 1/16" ID Tubing

7/16" HEX

.860"

10-32 Straight Threads

Seal 1/4" HEX

7-1/2°

.335"

1/8" NPT

Barb For 1/8" ID Tubing

7/16" HEX

.940"

Page 86: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 1999 ALL RIGHTS RESERVED e-mail [email protected] • web site www.okcc.com

Miniature Stainless Steel Fittings4

GENERAL SPECIFICATIONSPipe Connections/SAE 37° Flare

Maximum Operating Pressure – 4000 psigMaterials of Construction – 303 SS

Fluid Media – Air, Water, Gases and Liquids compatible with materials of construction

DimensionsDescription

Part Number CFJ6-295-SS

Part Number Dim. L HEX NPTB-191-SS ................ .97" 7/16" 1/8"E-312-SS ................ 1.38" 9/16" 1/4"

Part Number Dim. L HEX NPTD-159-SS ................ .88" 9/16" 1/8"G-312-SS ................ 1.25" 3/4" 1/4"H-312-SS ................ 1.69" 1-1/16" 1/2"

Part Number Dim. L HEX NPTBM-0-SS.................. .580" 7/16" 1/8"EM-0-SS.................. .800" 9/16" 1/4"

Part Number Dim. L HEX NPTBH-0-SS .................. .30" 3/16" 1/8"EH-0-SS .................. .46" 1/4" 1/4"

NPT

L

HEX

NPT

#6 SAE 37° Flare9/16" • 18 Thd

L

NPT

InternalHEX

HEX

L

NPT - Both EndsHEX PIPE NIPPLE

PIPE ADAPTER

PIPE PLUG

PIPE PLUG

SAE 37° FLARE ADAPTER

L

HEX

NPT

1.19"

11/16" HEX

.625"

Page 87: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 1999 ALL RIGHTS RESERVED e-mail [email protected] • web site www.okcc.com

5

DimensionsDescription10-32 x 1/8" NPT

10-32 x 1/4" NPT1/8" NPT x 1/4" NPT

10-32 x 10-32

Miniature Stainless Steel FittingsBulkhead Fittings

GENERAL SPECIFICATIONSBulkhead Connectors

Maximum Operating Pressure – Pipe Connections – 4000 psig • 10-32 Connections – 125 psigMaterials of Construction – Body – 303 SS • Nuts/Washers – 303 SS

Fluid Media – Air, Water, Gases and Liquids compatible with materials of construction

Part Number BUK1-159-SS

Part Number BUK2-159-SS

Part Number BUK3-159-SS

3/4" HEX1/2" - 20 NUT

1.70"

1/4" NPT1/2" Washer

10-32 Straight Threads

1/8" NPT

1.07"

3/8" - 16 NUT9/16" HEX

10-32 Straight Threads

3/8" Washer 1/8" NPT

1/4" NPT x 1/4" NPT

Part Number BUK4-219-SS

1/4" NPT5/8" Washer

1.96"

5/8" - 18 NUT3/4" HEX

1/4"NPT

10-32 Straight Threads Both Ends

5/16" Washer

.875"5/16" - 18 NUT

1/2" HEX

Page 88: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 1999 ALL RIGHTS RESERVED e-mail [email protected] • web site www.okcc.com

Part Number FFS-*-SS

Miniature Stainless Steel Fittings – Integral Screens6

BARB ADAPTER

10-32 COUPLING

10-32 ADAPTER

HEX NIPPLE

PIPE ADAPTER

GENERAL SPECIFICATIONS – Integral ScreensMaximum Operating Pressure — Pipe Connections - 4000 psig; 10-32 Connections - 125 psig; Barb Connections - 125 psig

Maximum Operating Pressure Differential Across Screen — 100 psigMaterials of Construction — Body - 303 SS • Seals - Viton • Screens - 304 SSFluid Media – Air, Water, Gases and Liquids compatible with materials of construction

DimensionsDescription

Part Number FMS-*-SS

Part Number Dim. L HEX NPTDSO-*-SS ............... .880" 9/16" 1/8"GSO-*-SS............... 1.250" 3/4" 1/4"

NPT

L

HEX

NPT

* SCREEN MICRON RATINGS – Replace in part number with designation shown below. PARTICLE RETENTION DESIGNATION IN

MICRON INCH PART NUMBER PART NUMBER EXAMPLES10 .0004 1 ESO-1-SS Type ESO Hex Nipple with 10 micron screen15 .0006 2 BWS-2-SS Type BWS Adapter with 15 micron screen25 .0010 5 FMS-5-SS Type FMS 10-32 Adapter with 25 micron screen100 .0040 20 DSO-20-SS Type DSO Pipe Adapter with 100 micron screen

Part Number Dim. L HEX NPTBSO-*-SS ............... .97" 7/16" 1/8"ESO-*-SS ............... 1.38" 9/16" 1/4"

Part Number Dim. L HEX TubingBTS-*-SS ................ .860" 7/16" 1/16"BWS-*-SS ............... .940" 7/16" 1/8"

*

HEX

L

NPT - Both Ends

1/8" NPT

Barb

HEX

L

Barbs Fit1/16" or 1/8"ID Tubing

.560"

.312" Dia.

10-32Threads

10-32Threads Round

Seal

.500"

.312" Dia.

10-32 ThreadsBoth Ends

Round

Page 89: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 1999 ALL RIGHTS RESERVED e-mail [email protected] • web site www.okcc.com

BREATHER

BREATHER

BOUND SCREEN

PLAIN SCREEN

SCREEN SLEEVE

D1

D2 L

Miniature Stainless Steel Fittings – Integral Screens

GENERAL SPECIFICATIONS – Integral ScreensMaximum Operating Pressure — Pipe Connections - 4000 psig; 10-32 Connections - 125 psig; Barb Connections - 125 psig

Maximum Operating Pressure Differential Across Screen - 100 psigMaterials of Construction — Body - 303 SS • Seals - Viton • Screens - 304 SS

Fluid Media – Air, Water, Gases and Liquids compatible with materials of construction

DimensionsDescription

* SCREEN MICRON RATINGS – Replace in part number with designation shown below. PARTICLE RETENTION DESIGNATION IN

MICRON INCH PART NUMBER PART NUMBER EXAMPLES10 .0004 1 SSA-1 Bound Screen - .211" Dia.; 10 micron screen15 .0006 2 QSB-2-SS Type QSB Breather with 15 micron screen25 .0010 5 XSB-5 Plain Screen - Type XSB; 25 micron screen100 .0040 20 SSC-20 Bound Screen - .312" Dia.; 100 micron screen

Part Number Dim. L HEX NPTBMB-*-SS ............... .650" 7/16" 1/8"EMB-*-SS ............... .900" 9/16" 1/4"

Part Number QSB-*-SS

Part Number D W ASSA-* ....................... .211" .030" .10"SSB-* ....................... .254" .030" .15"SSC-* ....................... .312" .030" .22"

Part Number D W**XSA-* ....................... .211" .005/.010"XSB-* ....................... .254" .005/.010"XSC-* ....................... .312" .005/.010"XSD-* ....................... .165" .005/.010"

Part Number L D1 D2 Press Fit BorePFA-SS................. .188" .222" .156" .219/.220"PFC-SS................. .188" .323" .250" .320/.321"

7

*

D

A

W

A

HEX

L

NPT

**Screen thickness range

W

D

1/4" HEX

.310"

10-32Threads

Page 90: Table of Contents - okcc. · PDF fileTable of Contents Page Picture Index ... Sapphire Orifice Assemblies ... Restriction Orifice Unions

P.O. BOX Q • TRUMBULL, CT 06611 • CT PHONE (203) 261-6711 • TOLL FREE PHONE (800) 533-3285 • FAX (203) 261-8331

© O'KEEFE CONTROLS CO. • 1999 ALL RIGHTS RESERVED e-mail [email protected] • web site www.okcc.com

Precision Orifices and Fluid Control Products

TYPE APLASTIC INSERT

Press fits into .125"/.126" Bore

TYPE LADAPTER

10-32 Thread by1/16" Barb

REQUEST CATALOG NO. 11 FOR DETAILS ON THESE PRODUCTSSapphire Orifice Assemblies – Pages 4-5

Metal NPT Orifices – Pages 8-9, 17-19

Orifice Kits – Pages 26-27

Metal Barb Orifices – Pages 6-7, 17-19

TYPE FPLASTIC INSERT

Press fits into .132"/.133" Bore

TYPE PBLEED PLUG10-32 Thread

TYPE JHEX NIPPLE

1/8" NPT

TYPE SDUAL BARB

For 1/16" ID Tubing

TYPE T or WDUAL BARB1/16" or 1/8"

TYPE M or NADAPTER

10-32 by 1/16" or 1/8" Barb

TYPE QBLEED PLUG10-32 Thread

Type BT or BWADAPTER

1/8" NPT by 1/16" or 1/8" Barb

Orifice Inserts - Press Fit – Page 10

Threaded Inserts – Page 11 Pressure Snubbers – Page 25

Miscellaneous Metal Orifices – Pages 12 - 13

Orifices with Integral Screens – Pages 20 - 21

PneumaticPressure andTemperature

SwitchesAir Output

Non-ElectricPages 38-39

Accessories – Pages 35-37

WaterTotalizer

with RemoteReadout

Air Proximity Sensors

TYPE AMFits into .126"/.127"

Dia. Hole

TYPE IAFits into .256"/.257"

Dia. Hole

TYPE IBFits into .0930"/.0940"

Dia. Hole

TYPE UFits into .279"/.280"

Dia. Hole

TYPE ZSet Screw Style

TYPE DP, GP or HP1/8", 1/4" or 1/2" NPT

TYPE BSHEX NIPPLE

1/8" NPT

TYPE QSBLEED PLUG10-32 Thread

TYPE BMMSBLEED PLUG

1/8" NPT

TYPE USDUAL SCREEN INSERT

Fits into .2795"/.2805" Dia. Hole

TYPE K4TUBE CONNECTION

1/4" OD Tube

TYPE R4CIRCULAR DISK

.47" Diameter

TYPE BFSSAE 45°

FLARE FITTING

Page 33

Fixed Flow H2O Orifices

Compressed Air Dryer

Page 42

Screen Products – Pages 22-24

TYPE SSA, SSB or SSCBOUND SCREEN

.211" .254" or .312" Diameter

TYPE FFSSCREEN FITTING

10-32 Thread

TYPE BMB or EMBBREATHER

1/8" or 1/4" NPT

TYPE DSO or GSOSCREEN FITTING

1/8" or 1/4" NPT Adapter

TYPE QSBBREATHER10-32 Thread

Orifice kits provide a widerange of orifice sizes andflow rate. Kits are availablefor metal and sapphireorifices as well as forMicro-Orifices®.

TYPE B or EHEX NIPPLE

1/8" or 1/4" NPT

TYPE D, G or HADAPTER

1/8", 1/4" or 1/2" NPT

TYPE BM or EMBLEED PLUG

1/8" or 1/4" NPT

TYPE BH or EHBLEED PLUG

1/8" or 1/4" NPT

Low PressureAir Switches

PrecisionPressure

Regulators Flowmeters Fittings

® Registered Trademark of O'Keefe Controls Co.

Micro-Orifices®

.0003" to .005" Dia.

Page 40

Pages 17-19

Digital Air Switches

Page 41

Page 34