table of contents...1 table of contents instruments introduction biodiamond abutment system...
TRANSCRIPT
![Page 1: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/1.jpg)
![Page 2: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/2.jpg)
1
Table of contents
Instruments
Introduction
BioDiamond Abutment system
BioDiamond Implant System
BioDiamond
5
3
About the Company
BioDiamond Proposer
6Technology and Quality
8Implant Surface Finish
9Packaging
14The Characteristic Properties of BioDiamond
16Fields of Application
18∅3.2 -Thin implant
20∅ 3.5 implants
22∅ 4.3 implants
24∅ 5.0 implants
26∅ 6.0 implants
30BioDiamond Abutments
32Sizes available of the abutments
38BioDiamond Instrument Kits
40BioDiamond Large Instrument Kit
42BioDiamond Small Instrument Kit
44Surgical Drills
46Ratchet Torque Wrench
50
Ball-headed implant, micro 52
Ball-headed implant, normal 54
Locator-headed implant 56
Multi-unit-headed implant 58
60BioDiamond mini - Instrument Kit
The applicational fields of BioDiamond mini
![Page 3: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/3.jpg)
2 BioDiamond Implant System
I It offers a versatile, complex, multifunctional solution customized to your needs for cases solved by tooth replacement. This is single and biphasic, that can be loaded immediately, extra thin, normal and extra shortly round-headed, locator headed, conical, multiunit headed, 39+ and half geometries of hibrid implants, plastic, zirconium, titanium and cobalt-based teethworks.
Versatility is more important than size but the BioDiamond system is also inimitable in range of sizes. This is a newly customized way in implantology. The R&D&I development technological system of the manufacturer guarantees the most optimal, unique size option individiually.
Intelligent Implant System. The manufacturer follows and integrates every scientific results from classic to the latest modern concepts, which takes into account the needs of the patient and the research that improves the efficiency of the dentist. Twists into the jaw with high pitch and self compression. Unique Biomimitek technology.
Although the intelligence is more important than the raw power but with the BIONIKA „Biotis” surface integration technology the BioDiamond is exceptionally superior in primer stability and unconquerable in osseointegration.
Total functional abutment system- There is also one that only exists in your imagination, if it can be devisable by present-day’s state of technology. The freedom of biological adaptation is Yours as well as the success. You are able to follow conscientiously the jaw structure of your patients for the implantation. The solution is in the BioDiamond system.
The manufacturer contributes with effective improvements, innovations, proffessional support and service to make you more productive with BioDiamond than any other product.
It is a guaranteed gurantee, this means the manufacturer guarantees the replacement of the implant even if there are no guaranteed conditions. The Biodiamond shows a return at all events -The eternal value diamond. It is a timeless investment.
Hajdú József Executive Director -BIONIKA Medline Kft.
In Dental Implantology
BioDiamond - SIMPLY GREAT, SURPASSES THE IMAGINATION
BioDiamond The New Trend
![Page 4: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/4.jpg)
3BioDiamond Implant System
![Page 5: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/5.jpg)
4 BioDiamond Implant System
![Page 6: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/6.jpg)
5About the company
BIONIKA Medline Orvostechnikai Kft. Is a member of the Swedish-Hungarian
group of companies. It was founded in 1989. The owners of the company
are Swedish and Hungarian citizens. We have a 30-year-experience in the
field of medical instruments and implant development, production and
trade.
BIONIKA as a researcher, developer, manufacturer and distributor is present
in dentistry, oral surgery, traumatology, orthopedics and rehabilitation in
the medical-professional areas.
According to our objective and perception, we attach great importance to
the word "BIONIKA", which marks a scientific thinking on the boundaries of
biology, technology and electronics that combines these three areas in our
researching and developing work
Clinical and technological experiences: The continuous process,
combination and utilization of clinical and technological experiences in
development contributes to our success, up to the production base. Here
you will find the best solutions and constructions suited to customer needs,
which are under continuous development.
Development: The owners of BIONIKA put great emphasis on continuous
product and technological research and development. Our products are
developed in close collaboration with doctors and engineers, enabling us
to ensure the world-class quality and practical utilization.
Quality: The quality of the products expected by our customers is
guaranteed by design, manufacturing and quality management according
to the harmonized European Union laws. The BIONIKA Medline Kft. is
operated according to the EN ISO 9001 and the EN ISO 13485 quality
management system. Our products are provided with CE marks.
Guarantee: After inserting the implant - the risk of the ossification process
is assumed by BIONIKA, independently of cause and effect relationship
– exchange guarantee is ensured within one year after the purchase.
Otherwise, we provide a long-term, 10-year guarantee for our products.
SZÁJSEBÉSZET
ORAL SURGERY
TRAUMATOLOGY
DENTISTRY
ORTHOPEDICS
About the company
![Page 7: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/7.jpg)
6 BioDiamond Implant System
Technology
Our Partners
BIONIKA Medline Kft. has 30 years of experience in the
development and production of dental implants, den-
tal insertion instruments and stomatological parts. Du-
ring this time more than 40 types of implant systems
have been developed and are being manufactured to
date, including insertion instruments.
Some of these parts have been developed for their
own marketing in accordance with their own market
needs. Other systems - in cooperation with indepen-
dent medical groups - are made to order, mainly devel-
oped and manufactured for foreign markets. (These are
sold by the customers under their own brand name).
Our partners can choose from approximately 20.000
different parts of different sizes and shapes. Our manu-
facturing technology is flexible, we can quickly move
from one component to another, and we are able to
fulfill thousands of orders with a short turnaround time.
This area requires high precision production (in some
cases it is necessary to hold 2-5μm tolerances). All the
technological operations we carry out are from manu-
facturing, surface design, packaging. Our products are
CE marked and the production process is under strict
quality management system.
Biocompatible materials are the most important raw
materials for dental, oral surgery, traumatology and ort-
hopedic medical implants.
Because relatively small series of customized solutions
are required, they require fast programmable CNC ma-
chining technology. Accordingly, we have molded CNC
machining centers and Swiss type longitudinal machi-
ning centers. For machining more complex surfaces, an
industrial 5-axis CNC center is used with CAD-CAM sys-
tem support. Our machines are equipped not only with
fixed , but also with propelled cutting instrument units,
with which we can perform more complex spatial geo-
metrical machining.
As a complementary technology, we have sandblast-
ing, polishing titanium coloring and sterilization equip-
ments.
The production of custom prosthetic components for
dental applications is supported by the BIONIKA Milling
center.
![Page 8: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/8.jpg)
7
Quality management and guarantee
Technology and Quality
The quality of the products is guaranteed by design,
manufacturing and quality management according
to the harmonized European Union laws. The BIONIKA
Medline Kft. is operated according to the EN ISO 9001
and the EN ISO 13485 quality management system.
Our products are provided with CE marks, which was
ensured by EMKI.
We provide a long-term, 10-year guarantee for our
products. After inserting the implant, reducing the
medical risk of the ossification process, independently
of cause and effect relationship – exchange guarantee
is ensured within one year after the purchase for the
dropped and fallen out implants.
BIONIKA Medline Kft. has always paid close attention
to quality and reliability during its nearly 30 years
of existence. The Bisnode certificate is proof of our
reliability and stability. BIONIKA received "Triple A"
Bisnode qualification from 2016 to 2019.
At the Hungarian market only 0.63% of the companies
have the AAA Bisnode rating. The financial risk of
establishing business relationship with these business
associations is extremely low - source: bisnode.hu
![Page 9: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/9.jpg)
8 BioDiamond Implant System
Superclean Implant Surface
Bionika implant electron microscope image *
Bionika implant electron microscope image *
Energy dispersive X-ray spectometric elemental analysis of Bionika implants*
* Source: FOGORVOSI SZEMLE, year 106. No. 4 2013. 135-143
BIONIKA demonstrates the best qualities of Grade 4
titanium used in implant manufacturing for dental
implantology according to the ISO 5832-2 ASTM F67
standard.
Due to its adequate purity the biocompatibility is
exceptionally good as well as it is provided with
exceptional solidity. Initially, we and other implant
manufacturers preferred the higher purity titanium
but due to solidity reasons nowadays almost every
implant is made of Grade 4 or other alloyed titanium
in the world.
In all cases of implant abutments, alloyed, high
strength Grade 5 titanium is applied according to the
ISO 5832-4 ASTM F136 standard. The titanium applied
according to the standard is provided with exceptional
biocompatibility, it is almost risk-free. Almost all
professionals see that the implantation success is best
determined by the implantologist's practice, as well as
surgical conditions, carefully maintained hygiene, and
patient abilities.
The main steps of our BioTiS surface finish technology:
• Chemical, mechanical surface cleaning and
surface dewing
• Special ultrasonic cleaning, surface cleaning and
sterilization
• Transformation of surface structure by acidification
process
• Multi-stage dehumidification, cleaning
• Electrochemical surface modification
• sterilization
• Surface finish in physiological solution
These technological steps are always carried out under
sterile conditions.
The final packaging of the implants is four-layered. The
packaging is carried out in a sterile cabin. Final sterility
is assured by an accredited 20 Rad gamma sterilization
procedure.
![Page 10: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/10.jpg)
9
Applied raw materials
Titanium grade 4
CoCr
Plastics
Titanium Grade 5
Chemical composition
Chemical composition
Chemical composition
Elements Threshold limit of constituents(%)
0 0,4 max.
Fe 0,3 max.
C 0,1 max.
N 0,05 max.
H 0,0125 max.
Ti >99% / balance
Elements Threshold limit of constituents(%)
C 0,1 max.
Si 1,0 max.
Mn 1,0 max.
P 0,005 max.
S 0,005 max.
Cr 30, 0 max.
Mo 7,0 max.
Ni 1,0 max.
Co -
N 0,2250 max.
Elements Threshold limit of constituents(%)
Al 5,5-6,75 max.
V 3,5-4,5 max.
Fe 0,3 max.
O 0,2 max.
C 0,08 max.
N 0,05 max.
H 0,015 max.
Ti balance
According to the ISO 5832-2 standard.
Mechanical properties
solidity 680 MPa min.
dilation 10 %
According to the ISO 5832-4 standard.
Mechanical properties
solidity 1240,00 MPa min.
elongation limit 900,00 min.
elongation at break 18,00 min.
fracture contraction 23,00 min.
According to the ISO 5832-3 standard.
solidity 860 MPa min.
dilation 10 %
Mechanical properties
POM (polyoxymethylene) : Thermoplastic synthetic plastic, Excellent properties eg: high hardness, low wear, good flexibility, little absorbing ability. Density: 1.41 g / cm3. elongation at break: min. 30% Current Voltage: min. 65 Mpa. Its color is white.
PEEK (polyether ether ketone) :High heat-resistant plastic, suitable for all conventional sterilization methods (steam, dry heat, ethylene oxide, gamma radiation). Density: 1.30 1.41 g / cm3 Tensile strength: 115 Mpa. elongation at break: min. 17% Its colour is natural brownish gray.
![Page 11: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/11.jpg)
10 BioDiamond Implant System
BioDiamond packaging
Collection box
In addition to this, depending on the order quantities, collection boxes with 5 and 10 pieces are applied.
10 - piece collection box vial in sterile foil removing the foil sterile vial
removing the locking plug removing the locking plug using the implant key driver using the implant key driver
![Page 12: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/12.jpg)
11
BioDiamond, Normál Implantátum4,30 x L13,00 mmØ
1008 2 STERILE R
500.002.425.130121214-08
2016-06
BIONIKA Medline Kft.3516 Miskolc Tégla utca 29.
www.bionika.hu
CM 007
2021-06
Packaging
Vial
The second layer of the packaging is a transparent vial, which ensures the total, null colony-forming unit sterility.
The locking plug of the vial holds the implant and the locking screw.
Paper box
The outer layer of the packaging is a paper box with a high density, which is for the physical safety.
Every paper box is provided with colour-coded labels according to the different platform- diameters. The colour of the packaging is adjusted to this method.
BioDiamond, Normál Implantátum4,30 x L13,00 mmØ
10112 STERILE
500.002.425.13019021803
2019-02
BIONIKA Medline Kft.3516 Miskolc Tégla utca 29.
www.bionika.hu
CM33-1
2024-02
BioDiamond, Normál Implantátum4,30 x L13,00 mmØ
10112 STERILE
500.002.425.13019021803
2019-02
BIONIKA Medline Kft.3516 Miskolc Tégla utca 29.
www.bionika.hu
CM33-1
2024-02
Ø4,30 x L13,00 mm (lila)
12121408
BioDiamond, Normál Implantátum
CM12
BioDiamond4,30 x L13,00 mmØ
CM22
![Page 13: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/13.jpg)
12 BioDiamond Implant System
BioDiamond packaging
The packaging of our implants is four-layered.
The first two layer is the implant holding poor
box and a transparent vial. This two layer en-
sures the total, null colony-forming unit sterility,
which is as a third layer is provided with a poly-
propylene, sterile foil due to high security rea-
sons.The fourth, outer layer of the packaging is
a paper box with a high density, which is for the
physical safety. In addition to this, depending on
the order quantities, collection boxes with 5 and
10 pieces are applied.
Vial locking plug
Implant locking screw
BioDiamond implant
Outer transparent packaging
![Page 14: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/14.jpg)
13Packaging
SCANDREA product labels and their notation
ø 6,0 x L13,00 mm
ø6,0 x L13,00 mm
CM22
CM12
530.001.600.130
BioDiamond
BioDiamond, Normál Implantátum ø6,0 x L13,00 mm (zöld)
The colour mark of the implant
Manufacturer’s logo, Product family name and parameters
Name and type of implant
Typical size of the implant
The colour code of the implant
The manufacturer’s logo, name and contact details
Name and type of implant
Implant size and color coding
Bar code
Label type
Label type
Information supplied by the three prod-uct labels on the outer packaging of the Implant System:
ø 3,0 - greyø 2,8 - turquoise ø 3,8 - yellow ø 4,3 - purple ø 5,0 - blue ø 6,0 - green 7,0 - white
Differential platform diameters by colour and diameter (mm):
Explanation of label codes:
Ø Diameter Expiration date NONSTERILE
Non-sterile product in the package
L Implant length It is forbidden to use in the case of damaged packaging. Read the usage guide!
Item number 2 Reuse is forbidden! Certificationcompany code
Serial number STERILE R Sterilized with gamma rays Manufacturer’s nameand Contact
Production time STERILE sterilized with steam or dry heat
The side of the box:
The back of the box :
Top of the box :
![Page 15: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/15.jpg)
14 BioDiamond Implant System
![Page 16: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/16.jpg)
15
![Page 17: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/17.jpg)
16 BioDiamond Implant System
A demand was raised during dental and implantological practice for a broadband compatibility between the dental implants. Thus, the BioDiamond Implant System family was developed, which brought significant changes in the case of implanting insert tools and abutments.
The characteristic properties of the BioDiamond biphase Implant System
Connection: Cone & hex
The complex and hexagon prism geometry ensures a perfect fixation. The 90 degree cone angle eventuates micromotor-free power transmission. It superimposes the powers deep right into the implant.
Cortical Level
The chances of the implant persistency are significantly improved by inserting the upper edge of the implant at the cortical level or below.
Platform switching
The diameter of the abutment is smaller than the outer part of the implant which is connected to the bone. The bone can move to the upper edge of the implant.
Spiral micro-grooved surfaceThe microstriated spiral surface can function as a significant weight bearing element. The self-closing thread structure and the cycloid cord thread ensure a micromotor-free condition and fast inserting.
Anatomical root-shape
- Due to the conicity, high thread pitch, high thread deepness, self-closing and self-tapping shaping of the implant screw thread, it has a bone-compacting effect and with due diligence it can be immediately loaded.
Rounded implant endIt helps facilitating the minor direction changes when inserting the implant.
![Page 18: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/18.jpg)
17
The functional structure of the BioDiamond system elements
Ø 3,5Ø 3,0 Ø 4,3 Ø 6,0Ø 5,0
FOR REMOVABLE TOOTHWORK
FOR GLUABLE TOOTHWORK
IMPLANT-LEVEL CASTING HEADS
HEALING CAPS
TEMPORARY ABUTMENTS
FOR SCREWED TOOTHWORK
ELEMENTS OF THE CAD-CAM SYSTEM
PROSTHETIC ELEMENTS
IMPLANTS
![Page 19: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/19.jpg)
18 BioDiamond Implant System
The applicational fields of the BioDiamond
In the case of one tooth deficit
In this case of the replacement of a tooth, we do
not have to grind two healthy teeth for bridge
replacement, but inserting an implant, then we need
to glue a crown in the same way as the traditional one.
In the case of end of line tooth deficit(s)
In this case, in the absence of a pillar tooth, we are
not able to make a fixed replacement (bridge). With
the implantation of at least two implants, you are
already make the (fixed) bridge replacement.make
the fixed bridge replacement.
In the case of total tooth deficit
In this case the patient has no tooth, complete tooth
augmentation can be performed. In this case, one
solution is the removable denture: 2-4 implants
are implanted, these will be the fixation for the
removable tooth. This brings a tremendous quality of
life to the patient, as this way the denture will be very
stable, so it can be used in chewing and speaking
outright.
There are two additional options within this solution:
you are able to use ball-head or locator heads.With
the implantation of several 6-8 implants, it is possible
to make full fixation (round bridge) augmentation,
which is both functional and aesthetically close to
the natural teeth.Removable denture
![Page 20: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/20.jpg)
19
Screw-retained fixed dental prosthetics
• The temporary denture can be inserted on the day
of surgery.
• Immediate improvement in function, speech and
aesthetically.
• Treatment times are shorter and costs can be lower
than conventional implant placement modes.
• Tilt rear implants can be fixed better into the front
bone. This promotes prosthesis support.
Optimum Concept
Safe Concept
Optimum ConceptAll-on-4® type - Economical Solution
Safe ConceptAll-on-6® type - For extra stability
• The usage of oblique head implants allows longer
implants to be used, avoiding the nerve canal.
• The usage of longer implants allows the bone
and the implant to touch on a larger surface, thus
making bone augmentation avoidable.
• Favorable bone level for tilted and axial implants.
• High remaining chances.
The Optimum Concept provides great stability, with only four implants being implanted.
The stability of the toothwork can be increased with the Safe Concept. It is exceptionally advantageous in the case of extra chewing ability.
nerve canal
Fields of application
![Page 21: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/21.jpg)
20 BioDiamond Implant System
BioDiamond Ø3.0 mm implant
The BioDiamond implant with ø3.0
mm platform and ø3.0 mm diameter
is exceptionally suitable in the
case of thinner than average bone
structures for fixing the toothworks
on the long run.
The raw material of it is
homogeneous titanium with a high
density.
2.1mm hex
Ø3.0mm platform
Ø3.0mm implant diameter
BioDiamond - Thin implant
hex 2.1 mmL 12 mm
hex 2.1 mmL 6 mm
hex 2.1 mmL 12 mm
hex 2.1 mmL 6 mm
BioDiamond manual implant key driver BioDiamond mechanical implant key driver
![Page 22: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/22.jpg)
21
The sizes available of the ø3.0 mm implant
Ø3.0
10 mm 11.5 mm 13 mm 14,5 mm 16 mm
Ø3.0
The drilling protocol of the BioDiamond ø3.0 mm implant
ø2,0 ø2,5 ø2,8 ø3,2 ø4,2 ø5,2
implant diameter
colour-coded drill diameter
- alternatively used
-recommended drilling in ¾ or in full length
- 1/2 length drilling alternatively
Drilling Indicators:
soft bone
hard bone
inserting length
ø3,7
∅3,0 Diameter
![Page 23: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/23.jpg)
22 BioDiamond Implant System
2.4mm hex
Ø3.5mm platform
Ø3.5mm implant diameter
BioDiamond Ø3.5 mm implant
The BioDiamond implant with
ø3.5 mm platform and ø3.5 mm
diameter is exceptionally suitable
in the case of thinner than average
bone structures for keeping the
toothworks on the long run.
The raw material of it is
homogeneous titanium with a high
density.
hex 2.4 mmL 6 mm
hex 2.4 mm
L 12 mm
hex 2.4 mm
L 6 mm
hex 2.4 mm
L 12 mm
BioDiamond - normal implants
BioDiamond manual implant key driver BioDiamond mechanical implant key driver
![Page 24: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/24.jpg)
23
Sizes available of the Ø3.5 mm implant
Ø3.5
Ø3.5
ø2,0 ø2,5 ø2,8 ø3,2 ø4,2 ø5,2
implant diameter
soft bone
hard bone
8 mm 10 mm 11.5 mm 13 mm 14.5 mm 16 mm
inserting length
ø3,7
∅3,5 Diameter
The drilling protocol of the BioDiamond ø3.5 mm implant
colour-coded drill diameter
- alternatively used
-recommended drilling in ¾ or in full length
- 1/2 length drilling alternatively
Drilling Indicators:
![Page 25: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/25.jpg)
24 BioDiamond Implant System
2.4mm hex
Ø3.50mm platform
Ø4.3mm implant diameter
BioDiamond Ø4.3 mm implant
The normal, BioDiamond implant
with Ø3.5 mm platform and Ø4.3 mm
diameter is exceptionally sutitable in
the case of average bone sructures for
keeping the toothworks on the long
run. The 75% of the occuring cases can
be covered with this type.
The raw material of it is homogeneous
titanium with a high density.
hex 2.4 mmL 6 mm
hex 2.4 mm
L 12 mm
hex 2.4 mm
L 6 mm
hex 2.4 mm
L 12 mm
BioDiamond manual implant key driver BioDiamond mechanical implant key driver
![Page 26: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/26.jpg)
25
Sizes available of the BioDiamond implant with Ø4.3 mm
Ø4.3
Ø4.3
ø2,0 ø2,5 ø2,8 ø3,2 ø4,2 ø5,2
8 mm 10 mm 11.5 mm 13 mm 14.5 mm 16 mm
implant diameter
soft bone
hard bone
ø3,7
∅4,3 Diameter
The drilling protocol of the BioDiamond ø4.3 mm implant
colour-coded drill diameter
- alternatively used
-recommended drilling in ¾ or in full length
- 1/2 length drilling alternatively
Drilling Indicators:
inserting length
![Page 27: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/27.jpg)
26 BioDiamond Implant System
The thick, BioDiamond implant
with ø3.5/5.0 mm platform and
ø5.0 mm diameter is exceptionally
suitable in the case of bigger than
average bone structures and normal
chewing ability for keeping the
toothworks on the long run.
The raw material of it is
homogeneous titanium with a high
density.
2.4mm hex
Ø3.50mm platform
Ø5.0 mm implant diameter
BioDiamond Ø5.0 mm implant
hex 2.4 mmL 6 mm
hex 2.4 mm
L 12 mm
hex 2.4 mm
L 6 mm
hex 2.4 mm
L 12 mm
BioDiamond manual implant key driver BioDiamond mechanical implant key driver
![Page 28: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/28.jpg)
27
Ø5.0
Ø5.0
ø2,0 ø2,5 ø2,8 ø3,2 ø4,2 ø5,2
Sizes available of Ø5.0 mm BioDiamond implant
implant diameter
soft bone
hard bone
6 mm 8 mm 10 mm 11.5 mm 13 mm 14.5 mm
ø3,7
∅5,0 Diameter
The drilling protocol of the BioDiamond ø5.0 mm implant
colour-coded drill diameter
- alternatively used
-recommended drilling in ¾ or in full length
- 1/2 length drilling alternatively
Drilling Indicators:
inserting length
![Page 29: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/29.jpg)
28 BioDiamond Implant System
2.4mm hex
Ø3.50mm platform
Ø5.0 mm implant diameter
BioDiamond Ø6.0 mm implant
The thick, BioDiamond implant
with ø3.5/6.0 mm platform and
ø6.0 mm diameter is exceptionally
suitable in the case of bigger than
average bone structures and normal
chewing ability for keeping the
toothworks on the long run.
The raw material of it is
homogeneous titanium with a high
density.
hex 2.4 mmL 6 mm
hex 2.4 mm
L 12 mm
hex 2.4 mm
L 6 mm
hex 2.4 mm
L 12 mm
BioDiamond manual implant key driver BioDiamond mechanical implant key driver
![Page 30: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/30.jpg)
2929
Ø6.00
Ø6.0
ø2,0 ø2,5 ø2,8 ø3,2 ø4,2 ø5,2
The sizes available of the ø6.0 mm implant
implant diameter
soft bone
hard bone
6 mm 8 mm 10 mm 11.5 mm 13 mm
ø3,7
∅6,0 Diameter
The drilling protocol of the BioDiamond ø6.0 mm implant
colour-coded drill diameter
- alternatively used
-recommended drilling in ¾ or in full length
- 1/2 length drilling alternatively
Drilling Indicators:
inserting length
![Page 31: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/31.jpg)
30 BioDiamond Implant System
![Page 32: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/32.jpg)
31
BioDiamondAbutment System
![Page 33: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/33.jpg)
32 BioDiamond Implant System
BioDiamond Abutments
1. IMPLANTS
PROSTHETIC ELEMENTS
2. Technical implant
3. Healing cap, narrow
4. Healing cap, anatomical
5. Sampling head for closed spoon
6. Sampling head for open spoon
7. Temporary head, through-bolted, positioned
8. Temporary head, through-bolted, non-positioned
9. Temporary head, through-bolted, positioned. PEEK
10. Temporary head, through-bolted, non-positioned, PEEK
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20.1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20.
FOR GLUABLE TOOTHWORK
11. Narrow head, straight
12. Narrow head, oblique
13. Universal head, straight
14. Universal head, oblique
15. Anatomical head, straight
16. Anatomical head, oblique
17. Trapezoidal head
18. Delta head
IMPLANT-LEVEL CASTING HEADS
19. Castable plastic head, positoned,
20. Castable plastic head, non-positioned
![Page 34: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/34.jpg)
33BioDiamond abutments
21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41.21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41.
21. Cobalt chromium-based casting head, positioned
22. Cobalt chromium-based casting head, non-positioned
23. Interface, positioned
24. Interface, non-positioned
25. Ball-joint head, positioned
26. Ball-joint head, non-positioned
FOR REMOVABLE TOOTHWORK
27. Ball-head
28. Locator head, straight
FOR SCREWED TOOTHWORK
29. Multi-unit head, straight
30. Multi-unit head, through-bolted
31. Multi-unit head, oblique
32. MC head, oblique
33. Multi-unit SR head, screwable
34. Multi-unit SR head, through-bolted with a threaded head
35. Multi-unit SR head, oblique
ELEMENTS OF CAD-CAM SYSTEM
36. Titanium base
37. Press ceramic base
38. Tube head, positioned
39. Tube head, non-positioned
40. Scanbody head, through-bolted
41. Scanbody head, screwable
![Page 35: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/35.jpg)
34 BioDiamond Implant System
2 4 6
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
12
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
12
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
2 4 6
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
11
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
12
height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
9
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
11
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
SAMPLING HEAD FOR OPEN SPOONTECHNICAL IMPLANT
HEALING CAP, NARROW
HEALING CAP, ANATOMICAL
SAMPLING HEAD FOR CLOSED SPOON
TEMPORARY HEAD, THROUGH-BOLTED, NON-POSITIONED
NARROW HEAD, STRAIGHT
TEMPORARY HEAD, THROUGH-BOLTED, POSITIONED
∅ 3.0
∅ 3.0
∅ 3.5
∅ 3.5
∅ 3.5
∅ 4.3
∅ 3.5
∅ 5.0
∅ 3.5
∅ 6.0
Selections of the BioDiamond abutments
platformdiameter (mm)
implantdiameter mm)
![Page 36: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/36.jpg)
35
2 4 6
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
12
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
12
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
11
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
9 11 13
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
11
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
9 11 13
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
9
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
12
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
2 4 6
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
Abutments
UNIVERSAL HEAD, STRAIGHT
NARROW HEAD, OBLIQUE 15°, 25°
UNIVERSAL HEAD, OBLIQUE 15°, 25°, 35°, 45°
ANATOMICAL HEAD, STRAIGHT
ANATOMICAL HEAD, OBLIQUE 15°, 25°
TRAPEZOIDAL HEAD 15°, 25°
CASTABLE PLASTIC HEAD, NON-POSITIONED
CASTABLE PLASTIC HEAD, POSITIONED
Co-Cr, METAL BASED CAST HEAD, POSITIONED
DELTA HEAD 15°, 25°
![Page 37: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/37.jpg)
36 BioDiamond Implant System
1 3
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
0,5 1 2 3 4 5 6 7
sulcus (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
0,5 1 2 3 4 5 6 7
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
1 3
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
0,5 1 2 3 4 5 6 7
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
12
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
0,5 1 2 3 4 5 6 7
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
BALL-JOINT HEAD, NON-POSITIONED
BALL HEAD
LOCATOR HEAD
MULTI-UNIT HEAD, STRAIGHT
MULTI-UNIT HEAD, THROUGH-BOLTED
BALL-JOINT HEAD, POSITIONED
∅ 3.0
∅ 3.0
∅ 3.5
∅ 3.5
∅ 3.5
∅ 4.3
∅ 3.5
∅ 5.0
∅ 3.5
∅ 6.0
Co-Cr, METAL BASED CAST HEAD, NON-POSITIONED
Selections of the BioDiamond abutments
1 2 3 4 5 6 7
sulcus height (S mm)
MULTI-UNIT HEAD, OBLIQUE 20°, 30°
platformdiameter (mm)
implantdiameter mm)
![Page 38: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/38.jpg)
37
1 2 3 4 5 6 7
sulcus height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
MULTI-COMPAT HEAD OBLIQUE 20°, 30°
5 7 9
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
PRESS CERAMIC BASE
12
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
SCANBODY HEAD, THROUGH-BOLTED
7 9 11
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
TUBE HEAD, POSITIONED
12
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
SCANBODY HEAD, SCREWABLE
0,5 1 2 3 4 5 6 7
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
MULTI-UNIT SR HEAD, SCREWABLE
5
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
TITANIUM BASE
Abutments
7 9 11
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
TUBE HEAD, NONE-POSITIONED
0,5 1 2 3 4 5 6 7
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
MULTI-UNIT SR HEAD THROUGH-BOLTED WITH THREADED HEAD
1 2 3 4 5 6 7
head height (mm)
platform (mm):
platform (mm):
∅ 3,0
∅ 3,5
MULTI-UNIT SR HEAD, OBLIQUE 20°, 30°
![Page 39: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/39.jpg)
38 BioDiamond Implant System
![Page 40: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/40.jpg)
39
BioDiamondInstrument kits
![Page 41: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/41.jpg)
40 BioDiamond Implant System
BioDiamond Instrument kits
The instrument trays are built up according to the surgical order,
graphics makes their use easier.
Large Instrument kit
1
2
OPENING
![Page 42: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/42.jpg)
41Instrument kits
Small Instrument kit
CLOSING
![Page 43: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/43.jpg)
42 BioDiamond Implant System
BioDiamond large instrument kit
6 8
10
12
1
2
4
5
3
7
9
11
13
16
17
18
19
15
22
14
20
21
![Page 44: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/44.jpg)
43Instrument tray
Depth gauge3 Implant driver, manual, 6Lt2,4xL1214
Core drill4 Gingiva punch ∅4,0xL1515
Thread groove calibrating drills5 Head wrench, mechanical 6Lt1,27xL1016
Indicators6 Head wrench, mechanical 6Lt1,27xL1517
Implant driver, mechanical, 6Lt2,1xL128 Head wrench, manual 6Lt1,27xL1519
Implant driver, mechanical, 6Lt2,1xL67 Head wrench, manual 6Lt1,27xL1018
Locator key20Implant driver, mechanical, 6Lt2,4xL69
Multi-unit/ Ball head key, 6Lt2,7 21Implant driver, mechanical, 6Lt2,4xL1210
Ratchet torque wrench22Implant driver, manual, 6Lt2,1xL611
Implant driver, manual, 6Lt2,1xL1212Spear-pointed drill1
Pre-drills2 Implant driver, manual, 6Lt2,4xL613
![Page 45: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/45.jpg)
44 BioDiamond Implant System
BioDiamond small instrument kit
6
8
1
2
3
4
5
7
10
9
13
12
11
![Page 46: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/46.jpg)
45Instrument kit
Spear-pointed drill1
Implant driver, manual, 6Lt2,4xL127
Pre-drills2
Depth gauge3
Core drills 4
Paralleling pins5
Implant driver, mechanical, 6Lt2,4xL126
Gingiva punch ∅4,0xL158
Head wrench, mechanical 6Lt1,27xL109
Head wrench, manual 6Lt1,27xL1010
Locator key11
Multi-unit/ Ball head key, 6Lt2,7 12
Ratchet torque wrench13
![Page 47: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/47.jpg)
46 BioDiamond Implant System
Surgical drills
Vertex
6 mm
8 mm
10 mm
11,5 mm
13 mm
16 mm
14,5 mm
The BIONIKA drills - which can be used du-
ring implant insertion - are available in a
wide range of sizes (compatible with diffe-
rent instrument kits to provide you with the
most economical solution).
Our drills are externally cooled and have
bone collecting properties. Acidic alloy
steel and excellent sharpness guarantee
long-term use. Each drill is provided with
the required drilling depths. Diameters are
indicated by color codes.
Core drills are suitable for preparing implant
nests. They are recommended for use accor-
ding to the drilling protocol, in the case of
softer and harder bone structure.
The Thread Calibrator Drills are suitable for
expanding the implant nests as needed, so
that we can extend the upper third of the
bone nest. They are recommended to use in
the case of harder than average bone struc-
ture.
![Page 48: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/48.jpg)
47
Sizes available of the surgical drills in the instrument kit
Surgical drills
SPEAR-POINTED DRILL
CORE DRILL ∅2,8 mm THREAD GROOVE CALIBRATING DRILL ∅3,2 mm
THREAD GROOVE CALIBRATING DRILL ∅3,7 mmCORE DRILL ∅3,2 mm
THREAD GROOVE CALIBRATING DRILL ∅4,2 mmCORE DRILL ∅3,7 mm
THREAD GROOVE CALIBRATING DRILL ∅4,7 mm
THREAD GROOVE CALIBRATING DRILL ∅5,5 mm
CORE DRILL ∅4,2 mm
CORE DRILL ∅4,7 mm
PRE-DRILL ∅2,5 mm PRE-DRILL ∅2.7 mm
PRE-DRILL ∅2,0 mm
![Page 49: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/49.jpg)
48 BioDiamond Implant System
Ratchet torque wrench
2.
1.
3.
4.
1. Ratchet torque wrench
2. Implant driaver, manual
3. Locking screw
4. BioDiamond implant
15 Ncm25 Ncm35 Ncmendless torque
The desired torques can be adjusted from 15 Ncm to the right
The ratchet torque wrench is used to tighten and insert
screws and implants. Using pre-set torque, this prevents
the implant from fracturing and ensures the optimum
power transfer when inserting the implant.
The scale of the torque rates from 15 to 35 Ncm, with
plus or minus 5% accuracy. The scale on the opposite
side can be used as a reverse torque. The ratchet torque
wrench can also function as a simple ratchet.
• ERGONOMIC CONSTRUCTION
• RELIABLE LIFETIME
• PRECISE TORQUE CONTROL
• STAINLESS STEEL
• SOUND SIGNAL
• REPLACABLE KEY INTERLINE
• STABLE TORQUE SCALE DURING
USE
• PROFESSIONAL QUALITY
![Page 50: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/50.jpg)
49
Locking screw Manual key driver
Healing cap Manual key driver
Sampling head screw for closed and open spoon Manual key
driverSampling head for closed and open spoon
Head screw
Ratchettorque wrench
20 Ncm
Multi-unit head screw,SR head screw
Multi-unit head, screwable
SR-head, screwable
Ball head
Locator head
Applications of Ratchet torque wrench
Ratchet torque wrench
HEADS AND SCREWS KEY INTERLINES TORQUE
Ratchet torque wrench
15 Ncm
Ratchet torque wrench
20 Ncm
Ratchet torque wrench
20 Ncm
Universal head, conical
Universal head, oblique
Anatomical head, straight
Anatomical head, oblique
Titanium base
Multi-unit head, through-bolted
![Page 51: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/51.jpg)
50 BioDiamond Implant System
![Page 52: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/52.jpg)
51
IMPLANT SYSTEM
![Page 53: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/53.jpg)
52 BioDiamond Implant System
The applicational fields of the BioDiamond
Removable toothworks
If the patient does not have a tooth, complete
tooth replacement can be made. In this case
one of the solutions is the removable denture.
Usually removable toothworks are 2-4, possibly
6-8 implants are implanted into the upper jaw,
considering bone quality, according to load
conditions. The round-head solution is a classic
solution. The most common fixing solution.
Both the 1.8 mm (micro) and 2.5 mm (normal)
diameter ball head implants can be found in the
BioDiamond mini systems. The application of
the locator or GPS torsion-shaped head single-
phase implants is relatively new compared
to this. These are also able to provide greater
stability to the denture in the case of less
implants.
The implant tooth fixations also provide a
tremendous quality of life for the patient in
the case of removable toothworks, as this will
make the denture much more stable than
conventional removable dentures. You can use
it exceptionally in chewing and talking as well.
Implanted removable dentures splinted together
Beside the implants, an individually prepared metal
splint can be inserted, which even provides greater
support and stability for the denture. The splint is
fastened to 2-5 implants.
![Page 54: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/54.jpg)
53Application
• The temporary denture can be inserted on the day of surgery.
• Immediate improvement in function, speech and aesthetically.
• Treatment times are shorter and costs can be lower than conventional implant placement modes.
The thin BioDiamond mini implants are also suitable with the Optimal Concept in the case of toothworks with great stability.
Advantages:
Advantages:
• The usage of longer implants allows the bone and the implant to touch on a larger surface, thus making bone augmentation avoidable.
• Favorable bone level for tilted and axial implants.
• High remaining and osseintegrational chances.
The stability of the toothwork can be increased with the Safe Concept. It is exceptionally advantageous in the case of extra chewing ability.
Optimum ConceptThe Economical Solution
Safe ConceptFor extra stability
Screw-retained fixed dental prosthetics with implants
Optimum Concept
Safe Concept
![Page 55: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/55.jpg)
54 BioDiamond Implant System
BioDiamond Ball-head implant, micro
6Lt 2.7 mm 6Lt 2.7 mm
The BioDiamond mini ball-head implants are suitable in the case of average hard and thin bone structures
for removable toothworks.
BioDiamond manual implant key driver BioDiamond mechanical implant key driver
![Page 56: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/56.jpg)
55
Sizes available of the micro ball-headed implant
inserting length (mm)
7 9 11 13 15 7 9 11 13 15 7 9 11 13 15
Ø2.5 Ø2.9 Ø3.3
lágy csont
lágy csont
kemény csont
kemény csont
lágy csont
kemény csont
BioDiamond
Ø2.5
Ø2.9
Ø3.3
Implant drilling protocol
∅1,5 ∅1,7 ∅2,1 ∅2,5implant diameter
colour-coded drilling diameters
- alternatively used
-recommended drilling in ¾ or in full length
- 1/2 length drilling alternatively
Drilling Indicators:
![Page 57: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/57.jpg)
56 BioDiamond Implant System
BioDiamond ball-head implant, normal
6Lt 2.7 mm 6Lt 2.7 mm
The BioDiamond mini ball-head implant is suitable in the case of average hard and thin bone structures for
removable toothworks.
BioDiamond manual implant key driver BioDiamond mechanical implant key driver
![Page 58: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/58.jpg)
57
Sizes available of the normal ball-head implant
7 9 11 13 15 7 9 11 13 15 7 9 11 13 15
Ø2.5 Ø2.9 Ø3.3
inserting length (mm)
lágy csont
lágy csont
kemény csont
kemény csont
lágy csont
kemény csont
BioDiamond
Ø2.5
Ø2.9
Ø3.3
Implant drilling protocol
∅1,5 ∅1,7 ∅2,1 ∅2,5implant diameter
colour-coded drilling diameters
- alternatively used
-recommended drilling in ¾ or in full length
- 1/2 length drilling alternatively
Drilling Indicators:
![Page 59: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/59.jpg)
58 BioDiamond Implant System
BioDiamond - locator-headed implant
The BioDiamond mini locator-headed implant is suitable in the case average hard and thin bone
structures for removable toothworks.
3Lt 2.15 mmL 10 mm
3Lt 2.15 mmL 10 mm
BioDiamond manual implant key driver BioDiamond mechanical implant key driver
![Page 60: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/60.jpg)
59
Sizes available of the locator-headed implant
7 9 11 13 15 7 9 11 13 15 7 9 11 13 15
Ø2.5 Ø2.9 Ø3.3
inserting length (mm)
lágy csont
lágy csont
kemény csont
kemény csont
lágy csont
kemény csont
BioDiamond
Ø2.5
Ø2.9
Ø3.3
Implant drilling protocol
∅1,5 ∅1,7 ∅2,1 ∅2,5implant diameter
colour-coded drilling diameters
- alternatively used
-recommended drilling in ¾ or in full length
- 1/2 length drilling alternatively
Drilling Indicators:
![Page 61: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/61.jpg)
60 BioDiamond Implant System
BioDiamond - multi-unit headed implant
6Lt 2.7 mm 6Lt 2.7 mm
The BioDiamond mini multi-unit headed implant is suitable in the case of average hard and thin bone
structures for screwed toothworks.
BioDiamond manual implant key driver BioDiamond mechanical implant key driver
![Page 62: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/62.jpg)
61
Sizes available of the multi-unit headed implant
7 9 11 13 15 7 9 11 13 15 7 9 11 13 15
Ø2.5 Ø2.9 Ø3.3
inserting length (mm)
lágy csont
lágy csont
kemény csont
kemény csont
lágy csont
kemény csont
BioDiamond
Ø2.5
Ø2.9
Ø3.3
Implant drilling protocol
∅1,5 ∅1,7 ∅2,1 ∅2,5implant diameter
colour-coded drilling diameters
- alternatively used
-recommended drilling in ¾ or in full length
- 1/2 length drilling alternatively
Drilling Indicators:
![Page 63: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/63.jpg)
62 BioDiamond Implant System
BioDiamond - Instrument Kit
1
2
OPENING
11
1
54
7
2
6
3
8
9
10
13
12
16
15
14
![Page 64: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/64.jpg)
63Instrument Kit
BioDiamond - The content of the Instrument Kit
Ratchet torque wrench16
Spear-pointed drill1
Depth gauge 3
Head wrench 6Lt 1,27xL1013
Manual implant driver 6Lt 2,7xL1012
Mechanical implant driver 6Lt 2,7xL1011
Locator key14
Converter adapter15
Paralleling pins4
Pre-drill ∅ 1,5 x L132
Core drill ∅1,7xL115
Core drill ∅2,1xL116
Core drill ∅2,5xL117
Thread calibrator drill ∅2,5/2,9xL119
Thread calibrator drill ∅2,7/3,3xL1110
Thread calibrator drill ∅2,3/2,5xL118
![Page 65: Table of contents...1 Table of contents Instruments Introduction BioDiamond Abutment system BioDiamond Implant System BioDiamond 5 3 About the Company BioDiamond Proposer Technology](https://reader034.vdocuments.us/reader034/viewer/2022042111/5e8c1b233ba144410e7493ad/html5/thumbnails/65.jpg)
BIONIKA MEDLINE KFT • [email protected] • www.bionika.hu • 3516 Miskolc, Tégla u. 29. • Tel.: +36 20 964-4146
Manufacturer: