t-seam standing seam roofing system standard details · 2017-04-08 · t-seam ® standing seam...
TRANSCRIPT
Tiger Profiles and Insulation L. L. C.
T-Seam®
Standing Seam Roofing System
Standard Details
Tiger Profiles & Insulation L.L.C.
Tiger Profiles and Insulation was established in 1994 as a fully owned
subsidiary of Tiger Steel Engineering to provide specialized service in the metal
building construction industry. In the last decade the company has grown to
be recognized as a market leader in the design and supply of the cold formed
and insulated metal building components for roofs, walls, false ceiling and
floor decks.
Tiger Profiles & Insulation employs a team of highly skilled and experienced
professionals, who work together with the customers to provide a complete
system solution. This entrepreneurial spirit of the employees has enabled the
Company to successfully launch new products and develop new markets.
The Company is committed to maintain the highest level of Quality Control
procedures as well as the health and safety policies resulting in high quality
products and ensuring complete customer satisfaction. The company has the
accreditation of ISO 9002 since 2000.
On the following pages, we have illustrated some typical T-Seam® roof
construction details. These details are only suggestions and must be verified for
each project in terms of correctness and suitability.
Introduction
T-Seam Standing Seam wasused for the roofing atZa’abeel Hall of the DubaiWorld Trade Centre.
Cover: T-Seam used forroofing the Ticketing Office atthe Nad Al-Sheba RaceCourse, Dubai. T-Seam is idealin situations where lightweight
yet durable roofing is required,and easily conforms to thedemanding specifications ofmodern architectural design.
T-Seam®
Standing Seam Roofing System
Standard Details
Drawing No. Drawing Title Page
SK 01 Typical Duo-pitch Detail 01
SK 02 Mono Pitch Ridge Detail 02
SK 03 Typical Roof Contsruction Detail 03
SK 04 Typical Roof Contsruction Detail 04
SK 05 Typical Rafter Contsruction Detail 05
SK 06 Gable with Wall Cladding 06
SK 07 Gable Detail with Parapet 07
SK 08 Peak Detail with Fascia 08
SK 09 Peak Detail on Block Wall 09
SK 10 Eave Gutter Details with Fascia 10
SK 11 Gutter Details without Fascia 11
SK 12 Valley Gutter Details 12
SK 13 Lateral Expansion Joint Detail 13
SK 14 Stepped Lateral Joint Detail 14
SK 15 Typical Overlap Pattern 15
SK 16 Typical Overlap Detail 16
SK 17 Expansion Joint Detail 17
SK 18 Roof Skylight Opening Detail 18
SK 19 Roof Skylight Opening Detail 19
SK 20 Soaker Panel Detail 20
SK 21 Fixing Clip Detail 21
SK 22 T-Seam® Accessories 22
Index 1
T-Seam® Standard DetailsDRAWING NO.
SK 01
Typical Duo-Ptich Detail
Line
r TR
35/2
00C
rimpe
d R
idge
Pro
file
Rid
ge F
lash
ing
Spa
cer
profi
le
Clo
sure
Fille
r
Rid
ge C
losu
re
Clo
sed-
end
Riv
et w
ith S
. S
Pin
T-S
eam
®
T-S
eam
® Fi
xed
Poi
nts
with
Riv
ets
Rid
ge T
urn
Up
STS
. Ø
6.5
x38m
m @
2 N
os/C
lip
ST-
Clip
with
The
rmal
Bar
rier
T-S
eam
®
Insu
latio
n
Vapo
ur B
arrie
r
Line
r TR
35/2
00
≥50
C o
f Rid
geL
≥70
> 1
00
2
T-Seam® Standard DetailsDRAWING NO.
SK 02
Mono Pitch Ridge Detail
& T-Seam® Fixed Point Detail
Peak Flashing
Spacer Profile
Ridge Turn UpT-Seam® Fixed Point
(ref. Detail)
Ridge Closure
Closure Filler
Closed-end RivetT-Seam®
Insulation
Vapour Barrier
Liner
Steel Structure
LooseInsulation
Inner SupportFlashing
SpacerSupport
WallPanel
M6 Bolt
T-Seam®
ST Clip withThermal Barrier
T-Seam® Fixed Point
3
T-Seam® Standard DetailsDRAWING NO.
SK 03
Typical Purlin RoofConstruction Detail
Without Hat Spacer
Self Tapping ScrewsØ6.5x38LG
(2 nos. per Clip)
Roof Purlin
T-Seam® Roof Panels
ST Clip with Thermal Barrier
Insulation
Vapour Barrier
Liner Sheet
T-Seam® Roof Panels
Insulation
Vapour Barrier
ST Clip with Thermal Barrier
Liner TR 35/200
T-Seam® Width
Self tapping screw
Section A -A
A
A
THK
THK
4
T-Seam® Standard DetailsDRAWING NO.
SK 04
Typical Purlin RoofConstruction Detail
With Hat Spacer
Curved T-Seam® Roof Panels
ST Clip with Thermal Barrier
Insulation
Vapour Barrier
Liner Sheet
Curved T-Seam® Roof Panels
ST Clip with Thermal Barrier
Insulation
Vapour Barrier
1.5mm Thk. Galv. Steel Mill FinishHat Section 30x30x65x30x30mm size
1.5mm Thk. Galv. Steel Mill FinishHat Section 30x30x65x30x30mm size
Self Tapping ScrewsØ6.5x38Lg (2 nos. per Clip)
Liner Sheet
Aluminium Bulb Tite Rivets fixed on both legs
T-Seam® Width
THK
Section A -A
A
A
Self Tapping Screw
Aluminium Bulb Tite Rivetsfixed on both legs
Self Tapping Screw
Roof Purlin
5
T-Seam® Standard DetailsDRAWING NO.
SK 05
Typical Rafter RoofConstruction Detail
T-Seam® Roof Panels
ST Clip with Thermal Barrier
Insulation
Vapour Barrier
Bulb Tite Rivets 4 nos. per Clip
Structural Deck
T-Seam® Roof Panels
Rafter
ST Clip with Thermal Barrier
Insulation
Vapour Barrier
Structural bDeck
T-Seam® Width
THK
Section A -A
A
A
Rafter
6
T-Seam® Standard DetailsDRAWING NO.
SK 06
Gable withWall Cladding
Liner TR35/200
ST Clip withThermal Barrier
Insulation
Vapour Barrier
T-Seam®
P. U. Board Insulation
Gable End Clip
Gable End Support
Gable End Channel
Rivet Ø4.8x11.5Lg.
Self Tapping ScrewsØ6.5x38Lg Long 2 nos./ Clip
STS for Liner
Z-Purlin
Gable Flashing
Closure Flashing
Ridge Closure
T-Seam® Fixed Pointwith Rivets
Cleader Angle Support
Closed-end Rivet
T-Seam®
Insulation
Liner TR35/200
ST Clip withThermal Barrier
7
T-Seam® Standard DetailsDRAWING NO.
SK 07
Gable Detailwith Parapet
T-Seam®
ST Clip withThermal Barrier
Insulation
Vapour BarrierLiner TR35/200
Gable Flashing
Gable End Clamp
Gable End Support Clip
Self Tapping ScrewsØ6.5x38Lg Long 2 nos./ Clip
STS 6.5x25Lg (8 nos. per Liner)for temp. fixing
Z-Purlin
P. U. Board Insulation
Gable Flashing
Flashing
Screws with FischerPlugs Ø6x50mm long
@ 400mm/CC
Silicon Sealants
Gable End Cliop (Channel)
T-Seam®
ST-Clip withThermal Barrier
Closure Flashing
Block Wall
Closed End RivetØ4.8x11.5 @ 300 C/C
STS Ø6.5x25mmLong 2nos./Clip
Detail X
X
8
T-Seam® Standard DetailsDRAWING NO.
SK 08
Peak Detail with Fascia
T-Seam® Fixed Point; 2 nos. Alum. Closed End Rivets with SS Pin
Ø4.8x11.5mm long @ every Seam
Fascia Panel
Cap Flashing
Flashing
Ridge Turn Up
Spacer Profile (Std) Fascia Panel
Peak Flashing
Ridge Closure with Filler (Std)
T-Seam®
Purlin
Liner TR35/200
Rigid PU Insulation Boards
Support Flashing
≥ 100
Steel Structure
9
T-Seam® Standard DetailsDRAWING NO.
SK 09
Peak Detail on Block Wall
T-Seam®
Insulation
Vapour Barrier
Liner TR35/200
Ridge Turn Up
Peak Flashing
Closure Filler
Ridge Closure
Closed End Rivet
T-Seam® Fixed Pointwith Rivets (ref. detail)
45º
11 – 12mm
Rivets 4.8x11Lg
Screws with Fischer PlugsØ6x50mm long @400mm/CC
Screws with Fischer PlugsØ6x50mm long @400mm/CC
P. U. Insulation
Flashing
Spacer Profile
Block Wall
Support Flashing
Z-Purlin
Self Tapping ScrewsØ6.5x38mm 2 nos./ Clip
Steel Rafter
T-Seam® Fixed Point Detail
11
T-Seam® Standard DetailsDRAWING NO.
SK 11
Gutter Detailswithout Fascia
10
T-Seam® Standard DetailsDRAWING NO.
SK 10
Eave Gutter Detailswith Fascia
Spacer Flashing
Top Skin Gutter
Trap Cowl (by others)
Eave Filler with Alum. Drip Angle
Closure Flashing
Vapour Barrier
ST Clip with Thermal Barrier
T-Seam®
PU Insulation Boards
Liner Gutter with Supports
Down Spout
Rain Water Down Pipes(by others)
Fascia Panel
Cap Flashing
Flashing
Fascia Support
≥ 100
300 max
Spacer Flashing
Eave Gutter
Trap Cowl (by others)
Eave Filler with Alum. Drip Angle
Closure Flashing
Vapour Barrier
ST Clip with Thermal Barrier
T-Seam®
Gutter Straps
Rain WaterDown Pipes(by others)
Down SpoutSteel Structure
THK
Composite Wall Cladding
300 max
12
T-Seam® Standard DetailsDRAWING NO.
SK 12
Valley Gutter Details
Trap Cowl (by others)
Top Skin Gutter
Drip Angle with Eave Filler
Insulation
Self Tapping Screws
Closure Flashing
T-Seam®
Insulation
ST Clip withThermal Barrier
Spacer Flashing
PU Insulation Boards
Vapour Barrier
Liner Gutter
Gutter Support
Gutter Down Spout
Rain Water Outlet(by others)
Liner TR35/200
Z-Purlin
13
T-Seam® Standard DetailsDRAWING NO.
SK 13
Lateral ExpansionJoint Detail
Extru
ded
ST
Clip
s to
be
fixed
alte
rnat
ivel
y of
T-S
eam
®P
anel
Sea
m
ST
Clip
with
The
rmal
Bar
rier
T-S
eam
® F
ixed
Poi
nt;
2 no
s. C
lose
d En
d R
ivet
s
Top
Ski
n G
utte
r
T-S
eam
® O
verla
p P
anel
Joi
nt(n
o fix
ing
for
expa
nsio
n)
Ref
. D
wg.
SK
15
Drip
Ang
le w
iht E
aves
Fille
r
Insu
latio
nLi
ner
TR35
/200
Vapo
ur B
arrie
r
Hat
Sec
tion
Dire
ctio
n of
Slo
pe
Dire
ctio
n of
Slo
pe
PU
Boa
rd In
sula
tion
Not
allo
wed
for
any
load
(inc
ludi
ng p
eopl
e w
alki
ng in
this
are
a).
LateralExpansion Joint
THK
Clo
sure
Fla
shin
gP
UB
oard
Insu
latio
n
Hat
sup
port
with
one
end
fixi
ngfo
r ex
pans
ion
@ 6
00m
m C
/C
T-S
eam
®
100
100
250
(X)
(1.5
X)
14
T-Seam® Standard DetailsDRAWING NO.
SK 14
Stepped LateralJoint Detail
T-S
eam
® Fi
xed
Poi
nt;
2 no
s. A
lum
.C
lose
d En
d R
ivet
s w
ith S
S P
inØ
4.8x
11.5
mm
long
@ e
very
sea
m
Eave
Fille
r
1.5
Thk.
GI.
Hat
Pro
file35
x40x
60x4
0x35
mm
fixed
with
Bul
b Ti
te R
ivet
s
1.5
Thk.
GI.
Hat
Pro
file35
x30x
60x3
0x35
mm
fixed
with
Bul
b Ti
te R
ivet
s
Scr
ews
6.5x
100m
m @
600
mm
C/C
T-S
eam
® R
oof P
anel
s
ST
Clip
with
The
rmal
Bar
rier
Clo
sed-
end
Riv
et w
ith S
. S
Pin
Sel
f Adh
esiv
e Ta
pe 4
mm
Rid
ge C
losu
re w
ith fi
ller
(Std
)
Ste
p Fl
ashi
ng
Z R
etai
ner
T-S
eam
® R
oof P
anel
s
Dire
ctio
n of
slo
pe
Vapo
ur B
arrie
r
Line
r TR
35/2
00
ST-
Clip
with
The
rmal
Bar
rier
Pur
lin S
uppo
rt
Ste
el T
russ
THK
Thick
Gap
15
T-Seam® Standard DetailsDRAWING NO.
SK 15
Typical Overlap Pattern
Note:1, 2, 3,& 4 indicates thesequence of laying of sheets
Direction of lay
x
x
Note: (x) Cut as shown
1
4
2
3
Sequence of Transverse Joint
16
T-Seam® Standard DetailsDRAWING NO.
SK 16
Typical Overlap Detail
ST Clip with Thermal Barrier
T-Seam®
Liner Sheet
Slope
Slope
1.5mm Galv. Steel Hat Section
G.I. Z-Purlin
Stainless Steel Self TappingScrew Ø6.5x25mm long @ 400mm C/C
Stainless Steel Self Tapping ScrewØ6.5x38mm long
2 nos./Clip
20 30 100
200
200100
50
5050
50
100
100
100
5050
5050
Silicone Sealant
Silicone Sealant
T-S
eam
® W
idth
Insulation
THK
Plan View
Aluminium Bulb Tite RivetØ5.1x19mm long @ 400mm
C/C on both legs
Alum. Closed End Rivetwith S. S. Pin
Ø4.8x11mm Long
Alum. Closed End Rivet with S. S. PinØ4.8x11mm Long
200
17
T-Seam® Standard DetailsDRAWING NO.
SK 17
Expansion Joint Detail
THK
.
3mm Thk. Flat Bar
* Allow. Expn.
*Allow. Expn.
*Allowable Expansion
Clip 100
600 C/C
Bulb Tite Rivet
Movement JointFlashing
1
12
2
2
X
T-Seam®
Exp. Cap Flashing
Alum. FlatSliding Bar
Alum. Flat Sliding Bar400x40
Exp. Cap Flashing
Gable End Channel
Fixed Point fixed with Rivets
Fixed Point fixed with Rivets
T-Seam®
ST-Clip with Thermal Barrier
Gable End Channel
Vapour Barrier laid toaccomodate movement
ST-Clip with Thermal Barrier
Self Tapping Screws2 nos. per Clip
Gable End Clip
THK
Isometric View of Sliding BarArrangement
Detail - X
Width of T-Seam® Width of T-Seam® Varies
C of Expansion JointL
Note:
*To be determined by calculations.
18
DRAWING NO.
SK 18
Roof Skylight Opening Detail
(Along the Roof)
Sky
light
(by
othe
rs)
Clo
sure
Fla
shin
g
PU
Boa
rd In
sula
tion
Gut
ter
Flas
hing
Alu
m.
Site
Wel
ding
GI Z
-Spa
cer
Alu
m B
ulb
Tite
Riv
et Ø
5.1x
19m
mLo
ng @
400
mm
C/C
on
both
legs
1.5m
m T
hk.
Hat
Sec
tion
Insu
latio
n
Sky
light
Sup
port
(by
othe
rs)
Line
r S
uppo
rt Fl
ashi
ng
Sky
light
Fla
shin
g(b
y ot
hers
)
Dire
ctio
n of
Slo
pe
Dire
ctio
n of
Slo
pe
Siz
e of
Sky
light
Clo
sure
Fla
shin
g
Vapo
ur B
arrie
r
Line
r TR
35/2
00
THK.
Pea
k Fl
ashi
ngR
idge
Clo
sure
with
Fille
rT-
Sea
m®
Fix
ed P
oint
ST
Clip
with
Ther
mal
Bar
rier
T-S
eam
®
50
30
50
Not
e:
*Thi
s de
tail
is a
pplic
able
for
T-S
eam
®
roofi
ng in
Alu
min
ium
mat
eria
l.
19
T-Seam® Standard DetailsDRAWING NO.
SK 19
Roof Skylight Opening Detail
(Across the Roof)
GI Z
-Spa
cer
Siz
e of
Sky
light
THK.S
kylig
ht (b
y ot
hers
)
Sky
light
Fla
shin
g (b
y ot
hers
)
Clo
sure
Fla
shin
g
ST
Clip
with
Ther
mal
Bar
rier
T-S
eam
®
PU
Boa
rd In
sula
tion
Gut
ter
Flas
hing
Alu
m.
Site
Wel
ding
Insu
latio
n
Vapo
ur B
arrie
r
Line
r TR
35/2
00
Sel
f Tap
ping
Scr
ews
Ø6.
5x38
Lg.
(2 n
os.
per
Clip
)
Sky
light
Sup
port
(by
othe
rs)
Insu
latio
n
Line
r S
uppo
rt Fl
ashi
ng
Not
e:
*Thi
s de
tail
is a
pplic
able
for
T-S
eam
®
roofi
ng in
Alu
min
ium
mat
eria
l.
20
T-Seam® Standard DetailsDRAWING NO.
SK 20
Soaker Panel Detail
Slope Slope
Slope Slope
Site Welding
T-Seam®
Aluminium Soaker Panel
Alum. Soaker(Rectangular)
Site Welding
T-Seam®
Soaker Panel Length
Opening Size Opening Size
HT.
Plan of AluminiumSoaker Panel
Isometric View ofRectangular Soaker
Cof Soaker
LC
of S
oake
rL
Soa
ker
Pan
el W
idth
Ope
ning
Siz
e
Wid
thW
idth
Wid
th
21
T-Seam® Standard DetailsDRAWING NO.
SK 21
Fixing Clip Details
R3
90º
60
6060
Ø6.1
Ø7.0
Ø6.1
4436
T2
T1
12
2.3
60
6
F
To
60
5
81
56
58441.
525
1.5
61
11
5
34
4
H
W
1.All dimensions are in millimetres.2.For sharp corners radius = 0.3R3.BS:1474 (amended version
BS EN 755 series for tolerancesunless mentioned otherwise.
4.F = full rad; R1 = 0.3 rad; R2 = 0.5 rad; R3 = 4.0 rad.
5.Material - Aluminium Alloy - 6082-T6 / 6063-T6.
Type T-25T-Seam® Fixing Clips
Type T-50 to T-135
Detail - X
Detail - YDetail - Z
R2
R2 R2
R1
R1R1
R1R1
R1R1
X X
YZ
T-Seam® Clip Type T-25 to T-135 (mm)Type
H
W
To
T1
T2
81
25
2.5
3.0
3.3
106
45
2.5
3.0
3.3
131
70
2.5
3.0
4.1
151
90
2.5
3.0
4.3
161
100
2.5
3.0
4.4
171
110
2.5
3.0
4.6
181
120
2.5
3.0
4.8
191
130
2.5
3.0
5.0
T-25 T-50 T-75 T-95 T-105 T-115 T-125 T-135
22
T-Seam® Standard DetailsDRAWING NO.
SK 22
T-Seam® Accessories
Drip Angle 20x40x2
T-Seam® Clamps
T-Seam® Clamps
T-Seam® Clamps
T-Seam® Eave Filler Block
T-Seam® Ridge Filler Block
T-Seam® Gable End Clamp
Gable End Clip (Channel)
Gable End Support (Clip)
Spacer Profile
Nylon Thermo Pad T-Seam® Clips
20
2758
27
35
18
27
60
45
45
42
7
8
2035
40
T-Seam roofing at CERT, Abu Dhabi.
Tiger Profiles and Insulation L. L. C.
Tel: +971 6 5338449 Fax: +971 6 5336673email: [email protected]. Box 23499, Sharjah, United Arab Emirates
www.tiger-group.co.ae